Upload
others
View
13
Download
0
Embed Size (px)
Citation preview
EDx Environmental Diagnostics
EDxPrime • EDxPlus
Beyond rack testing.Beyond compare.
Select from two PCR-based testing service options for more customized animal health monitoring with results in just 3 days.
IDEXX BioAnalytics
IDEXX BioAnalytics
Our EDx Environmental Diagnostics offers you the most flexible lab animal health monitoring services available. Regardless of what racks you have, the size of your facility, or how complex your exclusion list is—we’ve got you covered. EDxPrime and EDxPlus are two flexible testing services that allow you to customize your animal health monitoring program for the most effective solution for your facility—and your budget.
More options,more confidence.
A PCR-based animal health monitoring solution to test “just the racks.”
EDxPrime works with most
rack-based sample collection
types including:
• Plenum
• Cage
• Dust
• Filter/Media/Matrices
A customized monitoring solution with expanded sampling options.
EDxPlus includes rack testing
PLUS we’ll partner with you to
design a comprehensive AHM
program to included expanded
sample types such as Opti-Spot®,
feces, and swabs. We’ll help you
determine – from our extensive
assay portfolio and sampling
options – the best monitoring
solution for your facility.
EDxPlusEDxPrime
New EDx Profiles
In addition to these new EDx profiles, select from our full EDx portfolio of assays to customize a testing program that meets your unique health monitoring needs. Or, if you are not sure what service option might work best for you, Dr. Livingston here at IDEXX BioAnalytics and his team can help. They are available to discuss testing options with you and provide insight on the best solution for your facility.
MOUSE Profiles
Fur Mites • EPinworms • ESpironucleus muris • EEntamoeba muris • ETritrichomonas muris • EGiardia spp. • E
Parasite Panel
EDx Parasite Profile
MOUSE Profiles
Fur Mites • EPinworms • ESpironucleus muris • EEntamoeba muris • ETritrichomonas muris • EGiardia spp. • EHelicobacter • EPasteurella pneumotropica • E
EDx Primary* Profile
*Screens for agents not easily transmitted to sentinels
Sample Type*
Primary Panel Sample Type*
*Sample Type:
E = Environmental samples from open air flow design racks
• Specialized matrices or filters designed to capture exhaust air dust
• Flocked swab of rack exhaust air dust (prefilter, plenum)
• A sample of exhaust air dust (200 ul dust)
MOUSE Profiles
Bacteria- RespiratoryPasteurella pneumotropica • • • • E(Jawetz and Heyl biotypes)Myoplasma pulmonis • • • EStaphylococcus aureus • • EStreptococcus, ß-hemolytic • • E(Groups A, B, C, G)Bordetella bronchiseptica • EBordetella hinzii • ECorynebacterium kutscheri • EStreptobacillus moniliformis • EStreptococcus pneumoniae • ECARB • EC. bovis • EBacteria - EntericHelicobacter spp. – H. billis, H. ganmani, H. hepaticus, H. mastomyrinus, H. rodentium, H. typhlonius
• • • • E
Klebsiella oxytoca • • • EKlebsiella pneumoniae • • • ESalmonella spp. • • • ECitrobacter rodentium • • EClostridium piliforme • • EPseudomonas aeruginosa • • ECampylobacter spp. • EProteus mirabillis • EBacteria - SkinCorynebacterium bovis • EStaphylococcus xylosus • EFungiPneumocystis spp. • EVirusesMHV • • • • EMVM • • • • EMPV (1-5) • • • • EMNV • • • • ETMEV • • • • EMRV/EDIM • • • • EMAV1, MAV2 • • EReo Virus 1, 2 and 3 • EPneumonia virus of mice • ESendai virus • EEctromelia • EHantaan virus • ELymphocytic choriomeningitis virus • EParasites Pinworm – Syphacia obvelata, Aspiculuris tetraptera
• • • • E
Fur Mite – Myocoptes, Myobia and Radfordia spp.
• • • • E
Spironucleus muris • • • • EEntamoeba muris • • • • ETritrichomonas muris • • ECryptosporidium spp. • EGiardia spp. • E
Comprehensive GlobalBasicPrevelant
Mouse Standard Profiles
Sample Type*
EDx Profiles are easily customizable for your specific testing needs.
EDx Profiles
MOUSE Profiles
Bacteria- RespiratoryPasteurella pneumotropica • • • • E(Jawetz and Heyl biotypes)Myoplasma pulmonis • • • EStaphylococcus aureus • • EStreptococcus, ß-hemolytic • • E(Groups A, B, C, G)Bordetella bronchiseptica • ECorynebacterium kutscheri • EStreptobacillus moniliformis • EStreptococcus pneumoniae • ECARB • EBacteria - EntericHelicobacter spp. – H. billis, H. ganmani, H. hepaticus, H. mastomyrinus, H. rodentium, H. typhlonius
• • • • E
Klebsiella oxytoca • • • EKlebsiella pneumoniae • • • ESalmonella spp. • • • EClostridium piliforme • • EPseudomonas aeruginosa • • ECampylobacter spp. • EProteus mirabillis • EBacteria - SkinStaphylococcus xylosus • EFungiPneumocystis spp. • EVirusesRCV/SDAV • • • • ERPV • • • • EKRV • • • • EH-1 • • • • ERTV • • • • EBCV • • • • EMAV1, MAV2 • • EReo Virus 1, 2 and 3 • EPneumonia virus of mice • ESendai virus • ESeoul virus • EParasites Pinworm – Syphacia obvelata, Aspiculuris tetraptera
• • • • E
Fur Mite – Myocoptes, Myobia and Radfordia spp.
• • • • E
Spironucleus muris • • • • EEntamoeba muris • • • • ETritrichomonas muris • • ECryptosporidium spp. • EGiardia spp. • E
Comprehensive GlobalBasicPrevelant
Rat Standard Profiles
Sample Type*
*Sample Type:
E = Environmental samples from open air flow design racks
• Specialized matrices or filters designed to capture exhaust air dust
• Flocked swab of rack exhaust air dust (prefilter, plenum)
• A sample of exhaust air dust (200 ul dust)
EDx Profiles
The science is right in our data
EDx Study Design
We’ve “racked our brains” so you don’t have to. We continue to provide the science behind the service. We’ve conducted comprehensive studies on multiple racks to evaluate the effectiveness of environmental diagnostics for detecting rodent pathogens in ventilated racks. Various racks were used in the studies including Allentown, Tecniplast, Animal Care System and Innovive. Based on the study data, we’ve designed our EDxPrime and EDxPlus services to provide customers with flexible options for developing an effective animal health monitoring program that fits your unique needs.
Mice housed 3/cage on ventilated racks
Infected mice
5-10 cages of mice infected with each of the
following organisms:
MNV
MHV
MPV
Helicobacter spp.
Pasteurella pneumotropica
Entamoeba muris
Tritrichomonas muris
Pinworms
Furmites
Uninfected mice
10 cages of uninfected mice
Animal Care Systems
Filtered: cage exhaust filter
Every 2 weeks
– Colony mice were monitored by
PCR (feces, fur swabs) to determine
if they were shedding the organisms.
– Dirty bedding transferred to sentinels
End of 12 weeks, testing included:
– Colony and sentinel Mice:
serology, PCR- feces & fur swab
– Environmental Diagnostics (EDx)
Innovive
– Colony mice were monitored by
PCR (feces, fur swabs) to determine
if they were shedding the organisms.
Similar actions as above, but includes:
– Swabs are taken at plenum junction
– Sentinels are on a separate rack
Filtered: exhaust filter from sentinel cages
Every 2 weeks
– Colony mice were monitored by
PCR (feces, fur swabs) to determine
if they were shedding the organisms.
– Dirty bedding transferred to sentinels
End of 12 weeks, testing included:
– Colony mice and sentinel mice:
serology, PCR- feces & fur swab
– Environmental Diagnostics (EDx)
Unfiltered airflow cage exhaust
Allentown–Sentinel™
Tecniplast–Interceptor
1. Unfiltered (no filter at exit)
* Tecniplast
* Allentown
2. Filtered (air exits via filter)
* Animal Care Systems
* Innovive
* Thoren
* Lab Products
There are two types of IVC Cage Exhaust:
Allentown Sentinel™
Infected mice Sentinel mice EDx–Sentinel™
Agent 0w 2w 4w 6w 8w 10w 12w 12w
MNV 10/10 10/10 10/10 10/10 10/10 10/10 8/10 6/10 +
MPV 4/5 4/5 4/5 4/5 4/5 4/5 4/5 9/10 +
MHV 5/5 5/5 1/5 0/5 0/5 0/5 0/5 7/10 +
Helicobacter spp. 5/5 5/5 5/5 5/5 5/5 5/5 5/5 0/10 +
P. pneumotropica 5/5 5/5 5/5 5/5 5/5 5/5 5/5 0/10 +
E. muris 5/5 5/5 5/5 4/5 5/5 5/5 5/5 9/10 +
T. muris 0/5 1/5 1/5 1/5 1/5 1/5 1/5 0/10 –
Pinworms 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/10 +
Furmites 5/5 5/5 5/5 5/5 5/5 5/5 5/5 0/10 +
Allentown SentinelTM
• EDx testing of SentinelTM
detected pathogens missed by dirty bedding sentinel animals
• EDx testing is a valuable tool to include in your AHM program
Tecniplast: Interceptor
Infected mice Sentinel mice EDx–Interceptor
Agent 0w 2w 4w 6w 8w 10w 12w 12w
MNV 10/10 10/10 10/10 10/10 10/10 10/10 8/10 10/10 +
MPV 5/5 5/5 5/5 5/5 5/5 5/5 5/5 10/10 +
MHV 5/5 5/5 1/5 0/5 0/5 0/5 0/5 4/10 +
Helicobacter spp. 5/5 5/5 5/5 5/5 5/5 5/5 5/5 3/10 +
P. pneumotropica 5/5 5/5 5/5 5/5 5/5 5/5 5/5 0/10 +
E. muris 5/5 5/5 5/5 4/5 5/5 5/5 5/5 9/10 +
T. muris 5/5 5/5 5/5 5/5 4/5 5/5 5/5 0/10 –
Pinworms 5/5 5/5 5/5 5/5 5/5 5/5 4/5 6/10 +
Furmites 5/5 5/5 5/5 5/5 5/5 5/5 5/5 0/10 +
Tecniplast Interceptor
• EDx testing of Interceptor detected pathogens missed by dirty bedding sentinel animals
• EDx testing is a valuable tool to include in your AHM program
Animal Care Systems | Cage Exhaust Filter
Infected mice Sentinel mice
EDx–pooled1
EDx– 12 wks2
Agent 0w 2w 4w 6w 8w 10w 12w Filter Filter
MNV 8/10 7/10 7/10 7/10 7/10 7/10 3/10 10/12 3/3 1/3
MPV 5/5 5/5 5/5 5/5 4/5 5/5 4/5 12/12 3/3 3/3
MHV 5/5 5/5 2/5 0/5 0/5 0/5 0/5 6/12 1/3 0/3
Helicobacter spp. 5/5 5/5 5/5 5/5 5/5 5/5 5/5 0/12 3/3 3/3
P. pneumotropica 5/5 5/5 5/5 5/5 5/5 5/5 5/5 0/12 2/3 2/3
E. muris 5/5 5/5 5/5 5/5 5/5 5/5 5/5 10/12 3/3 3/3
T. muris 3/5 2/5 3/5 3/5 3/5 3/5 2/5 0/12 0/3 0/3
Pinworms 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/12 3/3 3/3
Furmites 5/5 5/5 5/5 5/5 5/5 5/5 5/5 0/12 2/3 2/31 Filter collected every 2 weeks and pooled. 2 Filter moved with sentinel cage and tested at the end of 12 weeks.
Innovive | Plenum Swab
Infected mice EDx–Plenum swab
Agent 0w 1w 2w 3w 4w 12w 12w
MNV 5/5 5/5 5/5 5/5 5/5 2/5 –
MPV 5/5 5/5 5/5 5/5 5/5 5/5 –
MHV 5/5 5/5 5/5 4/5 3/5 0/5 –
Helicobacter spp. 5/5 5/5 5/5 5/5 5/5 5/5 –
P. pneumotropica 5/5 5/5 5/5 5/5 5/5 5/5 –
E. muris 4/5 5/5 5/5 5/5 5/5 5/5 –
T. muris 4/5 5/5 5/5 4/5 5/5 5/5 –
Pinworms 5/5 5/5 5/5 5/5 5/5 5/5 –
Furmites 5/5 5/5 5/5 5/5 5/5 5/5 –
Animal Care Systems
• EDx testing detected pathogens missed by dirty bedding sentinel testing
• EDx testing is a valuable tool to include in your AHM program
Innovive
• EDx testing of plenums did not detect pathogens
• Type of rack and design of rack is important when implementing EDx monitoring programs
BioAnalytics© 2018 IDEXX Laboratories, Inc. All rights reserved. IBA-RE1 All ®/TM marks are owned by IDEXX Laboratories, Inc. or its affiliates in the United States and/or other countries. The IDEXX Privacy Policy is available at idexx.com.
To explore EDx options for your facility, contact IDEXX BioAnalytics: 1 800 669 0825 • idexxbioanalytics.com
EDx • 3R’sEnvironmental monitoring can play a key role while allowing you to Replace the use of animals with alternative testing techniques, Reduce the number of animals used to a minimum, and Refine the way health monitoring is done. IDEXX BioAnalytics Environmental Diagnostics support the 3R’s while providing high-quality research lab animal testing services so you’ll get results you can trust.