3
Edwards® 590 Series Class 2 Signaling Transformers Features Non-regenerative thermal overload protection Grounding wire Pre-stripped pigtails Screw terminal connections on sec- ondary Description Edwards 590 Series Class 2 Signaling Transformers are easy to install, low voltage power sources for residen- tial, commercial, and industrial uses. Agency Approvals • UL Listed CSAcertified Specifications Primary & secondary voltage: see chart Nylon bobbin construction Cadmium plated finish Installation Mounts in a standard 1/2" (13mm) knockout or surface mounts using the provided foot mounts. These transformers are suitable for mount- ing in both plastic and metal back boxes. May also be used with the Cat. No. 593 transformer plate for enclosed mounting in a standard two gang outlet box. Applications The Edwards 590, 590Y & 591 trans- formers are used in light duty appli- cations. They are ideal for standard doorbells and chimes in residential and commercial applications. The 592 & 592Y transformers are for commercial and residential use. The 24V, 20VA secondary is ideal for ap- plications requiring longer wire runs such as that needed in multiple fam- ily dwellings. The 596 transformer is used in light duty applications. It is ideal for stan- Cat. No. 598 Cat. No. 590 dard doorbells and chimes in residen- tial and commercial applications. Mul- tiple secondary voltages expand pos- sible usage. The Edwards 598, 598Y, 599 & 599Y transformers offer high power for long wire runs or for applications re- Cat. No. 596 quiring greater power such as door openers. Ideal for large apartments and building elevators. When select- ing transformers, attention should be given to the power requirements of the signal or load and the wire run between the transformer and load. 2 1/4" (57mm) 2 1/8" (54mm) Primary Volts Cat. No. 50/60 Hz Secondary Volts V A Dimensions A B 590 120V AC 10 2 5/16" (58.7mm) 31/32" (24.6mm) 590Y 240V AC 10 2 5/16" (58.7mm) 31/32" (24.6mm) 591 592 592Y 596 598 598Y 120V AC 120V AC 240V AC 120V AC 120V AC 240V AC 16 8 16 24 8 16 24 6 12 18 8 16 24 8 16 24 10 10 10 20 10 10 20 10 15 15 20 30 30 20 30 30 2 5/16' 2 1/2" 2 1/2" 2 1/2" 2 15/16 2 15/16 1 (58.7mm) (63.5mm) (63.5mm) (63.5mm) " (74.6mm) " (74.6mm) 31/32" 1 1/8" 1 1/8" 1 1/8" 1 5/8" 1 5/8" (24.6mm) (28.5mm) (28.5mm) (28.5mm) (41.3mm) (41.3mm) 599 120V AC 24 40 2 15/16" (74.6mm) 1 5/8" (41.3mm) 3 3 599Y 240V AC 24 40 2 15/16" (74.6mm) 1 5/8" (41.3mm) © 2000 EDWARDS CHESHIRE. CT 06410 www.edwards-signals.com SIGNALING 11-3 Fax-on-Demand # 1204

Edwards® 590 Series Class 2 Signaling Transformers · Edwards® 7005-G5 Hotel Room Annunciator Kit Features • High intensity strobe • Neutral beige color • Fits single gang

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Edwards® 590 Series Class 2 Signaling Transformers · Edwards® 7005-G5 Hotel Room Annunciator Kit Features • High intensity strobe • Neutral beige color • Fits single gang

Edwards® 590 Series Class 2Signaling Transformers

Features• Non-regenerative thermal

overload protection• Grounding wire• Pre-stripped pigtails• Screw terminal connections on sec-

ondary

DescriptionEdwards 590 Series Class 2 SignalingTransformers are easy to install, lowvoltage power sources for residen-tial, commercial, and industrial uses.

Agency Approvals• UL Listed• CSA certified

Specifications• Primary & secondary voltage:

see chart• Nylon bobbin construction• Cadmium plated finish

InstallationMounts in a standard 1/2" (13mm)knockout or surface mounts usingthe provided foot mounts. Thesetransformers are suitable for mount-ing in both plastic and metal backboxes. May also be used with theCat. No. 593 transformer plate forenclosed mounting in a standard twogang outlet box.

ApplicationsThe Edwards 590, 590Y & 591 trans-formers are used in light duty appli-cations. They are ideal for standarddoorbells and chimes in residentialand commercial applications.The 592 & 592Y transformers are forcommercial and residential use. The24V, 20VA secondary is ideal for ap-plications requiring longer wire runssuch as that needed in multiple fam-ily dwellings.The 596 transformer is used in lightduty applications. It is ideal for stan-

Cat. No. 598Cat. No. 590

dard doorbells and chimes in residen-tial and commercial applications. Mul-tiple secondary voltages expand pos-sible usage.The Edwards 598, 598Y, 599 & 599Ytransformers offer high power forlong wire runs or for applications re-

Cat. No. 596

quiring greater power such as dooropeners. Ideal for large apartmentsand building elevators. When select-ing transformers, attention should begiven to the power requirements ofthe signal or load and the wire runbetween the transformer and load.

2 1/4"(57mm)

2 1/8"(54mm)

Primary VoltsCat. No. 50/60 Hz

SecondaryVolts V A

DimensionsA B

590 120V AC 10 2 5 /16" (58.7mm) 31/32" (24.6mm)

590Y 240V AC 10 2 5/16" (58.7mm) 31/32" (24.6mm)591

592

592Y

596

598

598Y

120V AC

120V AC

240V AC

120V AC

120V AC

240V AC

168162481624612188162481624

10101020101020101515203030203030

2 5/16'

2 1/2"

2 1/2"

2 1/2"

2 15/16

2 15/16

1 (58.7mm)

(63.5mm)

(63.5mm)

(63.5mm)

" (74.6mm)

" (74.6mm)

31/32"

1 1/8"

1 1/8"

1 1/8"

1 5/8"

1 5/8"

(24.6mm)

(28.5mm)

(28.5mm)

(28.5mm)

(41.3mm)

(41.3mm)

599 120V AC 24 40 2 1 5 / 1 6 " (74.6mm) 1 5/8" (41.3mm)

3 3

599Y 240V AC 24 40 2 1 5 / 1 6 " (74.6mm) 1 5/8" (41.3mm)

© 2000 EDWARDSCHESHIRE. CT 06410www.edwards-signals.com S I G N A L I N G

11-3Fax-on-Demand # 1204

Page 2: Edwards® 590 Series Class 2 Signaling Transformers · Edwards® 7005-G5 Hotel Room Annunciator Kit Features • High intensity strobe • Neutral beige color • Fits single gang

Edwards® 6538-G5Call For Assistance Kit

Features• High intensity strobe• Neutral beige color• Fits single gang box

DescriptionThe Edwards 6538-G5 Call For Assis-tance system is designed for areaswhere a call-for-help or an emer-gency switch is required. The kit con-sists of a Cat. No. 6536-G5 horn/strobe for audible and visual signal-ing, a Cat. No. 6537 emergency pullcord station, and a Cat. No. 592transformer. Each component mayalso be ordered individually. See theapplicable component catalog pagefor a detailed description of thatcomponent.

6536-G5 Horn/StrobeThe Cat. No. 6536-G5 Horn/Strobe isdesigned for use in a single gang 2"(51mm) x4" (102) box located overdoors of restrooms. Each unit con-tains an audible horn signal whichgenerates an 82 dBA sound pressurelevel at 10 ft. and a high intensity110 candela (strobe) visual signal. Seepage 14-10.

592 TransformerThe Edwards Cat. No. 592 trans-former is used to power the horn/strobe. It is equipped with a ground-ing wire and is suitable for installa-tion in both plastic and metal boxes.See page 1 1 - 3 .

6537 Pull Cord StationThe Cat. No. 6537 pull cord stationprovides emergency call activation

with a reset at the call initiating sta-tion. It has a stainless steel face platewith a DPST switch. See page 1 4 - 1 1 .

Agency Approvals• Transformer and horn/strobe UL

Listed

Specifications• Transformer primary: 120V AC;

secondary: 24V AC• Horn/strobe current draw: 175 mA

at 24V 50/60 Hz and 125 mA at24V DC

InstallationFlush or surface mounted. See appli-cable component catalog page.

ApplicationsUse in health care facilities, publicrest-rooms, and handicapped areas.

iffO t/i o

© 2000 EDWARDSCHESHIRE, a 06410www.edwards-signals.com S I G N A L I N G

14-3Fax-on-Demand # 1278

i.

Page 3: Edwards® 590 Series Class 2 Signaling Transformers · Edwards® 7005-G5 Hotel Room Annunciator Kit Features • High intensity strobe • Neutral beige color • Fits single gang

Edwards® 7005-G5 Hotel RoomAnnunciator Kit

Features• High intensity strobe• Neutral beige color• Fits single gang box

DescriptionThe Edwards 7005-G5 Hotel RoomAnnunciator is for use in hotel roomsand other areas designed to accom-modate those with audible, visual, orphysical impairments. The kit con-sists of a Cat. No. 6536-G5 horn/strobe for audible and visual signal-ing, a Cat. No. 620 push button, a Cat.No 147-10 mounting plate, and a Cat.No. 592 transformer. Each compo-nent may also be ordered individu-ally. See the applicable componentcatalog page for a detailed descrip-tion of that component.

6536-G5 Horn/StrobeThe Cat. No. 6536-G5 Horn/Strobe isdesigned for use in a single gang 2"(51mm) x4" (102) box located overdoors of restrooms. Each unit con-tains an audible horn signal whichgenerates an 82 dBA sound pressurelevel at 10 ft. and a high intensity110 candela (strobe) visual signal. Seepage 14-10.

592 TransformerThe Edwards Cat. No. 592 trans-former is used to power the horn/strobe. It is equipped with a ground-ing wire and is suitable for installa-tion in both plastic and metal boxes.See page 1 1 - 3 .

620 Push ButtonThe Cat. No. 620 push button stationprovides call activation when in-stalled in the 147-10 mounting plate

(page 14-9). The plate has a stainlesssteel face. The switch is momentary.See page 10-10.

Agency Approvals•Transformer and horn/strobe UL

Listed

Specifications•Transformer primary: 120V AC;

secondary: 24V AC• Horn/strobe current draw: 175 mA

at 24V 50/60 Hz; 125 mA at 24V DC

InstallationSee applicable component catalogpage.

ApplicationsUse in hotels, health care facilities,public rest-rooms, and handicappedareas.

© 2000 EDWARDSCHESHIRE, CT 06410www.edwards-signals.com S I G N A L I N G