ECONOMAXHigh Velocity System
AIRMAX TechnologIes, 209 cITATIon DRIve, UnITs 5&6,concoRD, on, cAnADA, l4K 2Y8Telephone (905) 264-1414 - FAX (905) 264-1147
e-MAIl: [email protected] - Web sITe: WWW.AIRMAXTechnologIes.coM
Max Comfort• Hydronic Heating using a hot water coil delivering comfortable,
efficient heat to your home.• Your home is less dry then a typical gas furnace.
Max Energy Savings• Optional ultra high efficient electronic commutated motor (ECM)
to produce constant air circulation using very little energy.• Hydronic furnace requires no venting or gas lines with reduced
installation costs.• Reduced outlets and Mini Duct reduce system costs
Max Flexibility• Multi-position and flexible installation (basement, closet, crawl space or
attic) used in new construction and retrofit applications.• Can accommodate cooling, humidifiers, hrvs and whole house air
cleaners while utilizing conventional ducting systems.• Hydronic Air Handler can accommodate most brands of cooling coils
and chilled water coils. This allows HVAC professionals to use the equipment of their choice.
• Must be matched with a dual purpose tankless hot water heater, boiler, water heater or heat pump.
• Three compact sizes ranging from 21,000 BTU to 98,000 BTU and from 1 to 3 tons of cooling.
Product SPecificationS Product dimenSionS
economaX Product BenefitS
ECONOMAX Models
BTUH Heating @ 180º F EWT
BTUH Heating @ 170º F EWT
BTUH Heating @ 160º F EWT
BTUH Heating @ 150º F EWT
BTUH Heating @ 140º F EWT
BTUH Heating @ 130º F EWT
TX Cooling (Tons)(1)
CFM @ 1.5" ESP
HP - RPM
Motor Amps @ 120/1/60
GPM Flow Rating
Fan Coil Size (L/W/H)
Supply Air Size
Return Air Size Required
Minimum Outlets
Maximum Outlets
Max 50 (ecm)
55,649
49,971
44,700
39,086
35,195
30,250
1½ - 2.0
580
½ - 1,625
6.2
5
30"x14"x18½"
8
12"x14" min.
13 (10-ecm)
17 (17-ecm)
Max 30 (ecm)
39,382
35,769
32,159
28,553
24,951
21,356
1.0
350
¹⁄ - 1,625
4.6
5
30"x14"x18½"
8
12"x14" min.
7 (5-ecm)
11 (11-ecm)
Max 70 (ecm)
77,981
69,804
58,902
50,519
46,278
41,000
2½
750
¾ - 1,625
8.7
7
36"x18"x19½"
8
16"x15" min.
16 (16-ecm)
20 (20-ecm)
Max 100 (ecm)
98,593
89,630
80,666
71,704
62,741
53,500
3
950
¾ - 1,625
8.7
8
36"x18"x25½"
10
16"x16" min.
19 (22-ecm)
25 (28-ecm)
(1) Smaller condensers maybe matched to fan coil when required ( match TXV to condenser size)(2) The median number of outlets should be used to achieve maximum DX cooling capacity for each model size. Eg. If 2 1⁄2 tonsare required in a Max 70 system you must use minimum 20 outlets. Heating capacity based on 70oF return air, high speed,10’ duct length per branch and no cooling.(3) Contact factory for minimum number of outlets if using less than maximum DX cooling capacity.*ecm - Electronically Commuted Motor