The New Economical: Higher Flow Rates Ecological: Lower Energy Costs The ideal Variable Frequency Controller for installations with 3-phase, 380-415V input power. The EcoVFC optimizes Intelligent Submersible Turbine (IST) performance, as follows: n 20-25% Higher Flow During Peak Business Hours n Reduced Energy Consumption Features and Benefits n Designed For Fuel Management System Integration n When installed with INCON fuel management systems, the EcoVFC networks to the tank gauge to improve throughput and profitability by automatically resetting transient errors in the fueling system. Refer to INCON TS-TPI brochure for details. n Allows reporting of pump alarms to remote service providers, reducing troubleshooting time and maintenance costs. n Environmental Protection - The EcoVFC will shut the pump off after running for 60 minutes with no change in pumping activity, enhancing accuracy of line leak detection. n Dual 7-Segment Displays - Clearly indicate pump operating status and condition codes. Also included is a yellow LED to indicate communications activity with multiple pumps and/or with INCON tank monitoring equipment. n Manifolded Pump Control - Allows operation of multiple pumps in accordance with the flow demanded in the station. In manifolded pump applications, on-demand “auto-start” of additional pumps as station’s flow demand increases and/or if abnormal operating condition occurs with one of the pumps. n Auto Restart From Underload (Dry Run) Fault - The EcoVFC is capable of restarting and automatically clearing a dry run fault. Eliminates the need to manually reset after filling storage tank. n Fault Read Out - When activated, the EcoVFC will display the last three (3) fault conditions encountered. Increases station operating profit by simplifying troubleshooting, and reducing maintenance costs and “down time”. n Audible Alarm - Clearly indicates fault conditions. Includes silence button for acknowledging faults. Variable Frequency Controller

Eco VFC

Embed Size (px)

DESCRIPTION

Economical: Higher Flow Rates Ecological: Lower Energy Costs The ideal Variable Frequency Controller for installations with 3-phase, 380-415V input power. The EcoVFC optimizes Intelligent Submersible Turbine (IST) performance, as follows: n 20-25% Higher Flow During Peak Business Hours n Reduced Energy Consumption

Citation preview

The New Economical: Higher Flow RatesEcological: Lower Energy Costs

The ideal Variable Frequency Controller for installations with 3-phase, 380-415V input power. The EcoVFC optimizes Intelligent Submersible Turbine (IST) performance, as follows:

n 20-25% Higher Flow During Peak Business Hours

n Reduced Energy Consumption

Features and Benefits

n Designed For Fuel Management System Integration

n When installed with INCON fuel management systems, the EcoVFC networks to the tank gauge to improve throughput and profitability by automatically resetting transient errors in the fueling system. Refer to INCON TS-TPI brochure for details.

n Allows reporting of pump alarms to remote service providers, reducing troubleshooting time and maintenance costs.

n Environmental Protection - The EcoVFC will shut the pump off after running for 60 minutes with no change in pumping activity, enhancing accuracy of line leak detection.

n Dual 7-Segment Displays - Clearly indicate pump operating status and condition codes. Also included is a yellow LED to indicate communications activity with multiple pumps and/or with INCON tank monitoring equipment.

n Manifolded Pump Control - Allows operation of multiple pumps in accordance with the flow demanded in the station. In manifolded pump applications, on-demand “auto-start” of additional pumps as station’s flow demand increases and/or if abnormal operating condition occurs with one of the pumps.

n Auto Restart From Underload (Dry Run) Fault - The EcoVFC is capable of restarting and automatically clearing a dry run fault. Eliminates the need to manually reset after filling storage tank.

n Fault Read Out - When activated, the EcoVFC will display the last three (3) fault conditions encountered. Increases station operating profit by simplifying troubleshooting, and reducing maintenance costs and “down time”.

n Audible Alarm - Clearly indicates fault conditions. Includes silence button for acknowledging faults.

Variable Frequency Controller

Specifications

FFS-0006 Rev. A 5/04

Performance

Variable Frequency Controller

3760 Marsh RoadMadison, WI 53718, U.S.A.Tel: +1 608 838 8786 • Fax: +1 608 838 6433Tel: USA & Canada 1 800 225 9787Tel: Mexico 001 800 738 7610www.franklinfueling.com

Dimensions: 36.2cm H x 14.0 cm W x 24.1cm D

Operating Temperature: Between 4°C and 35°C

Power Requirements: 380-415V, 3 Phase, 50 or 60 Hz Input

Output Power: 190V, 3 Phase Variable Frequency

Listing: CE Marked

Self-Diagnostics Display Codes

Bar

Liters Per Minute� �� ��� ��� ��� ��� ��� ��� ���

���

���

���

���

���

���

���

���

������������������������������������������

Under-Load, Tank EmptyLow Incoming VoltageLocked Rotor Fault at PMA StartupExtended RunUpper Rail Short

Capacitor BankOver SpeedOpen CircuitShort CircuitHigh Temperature

Curves shown reflect single pump performance pumping gasoline (SG.76)

EcoVFC operating on 380-415V three phase input.

MagVFC operating on 200-250V single phase input.

�������

��������������������

������������

�������

�������

���������������