DEVELOPMENT APPLICATION
PDPLANPMTD-2021/016351
APPLICANT: Wilson Homes
PROPOSAL: Dwelling
LOCATION: 10 Pardalote Close, Opossum Bay
RELEVANT PLANNING SCHEME: Clarence Interim Planning Scheme 2015
ADVERTISING EXPIRY DATE: 18 August 2021
In addition to the Application Form(s), Certificate of Title(s) and any associated
consent documents the following information is available on request:
• Nil
The relevant plans and documents can be inspected at the Council offices, 38 Bligh
Street, Rosny Park, during normal office hours until 18 August 2021. In addition to
legislative requirements, plans and documents can also be viewed at
www.ccc.tas.gov.au during these times.
Any person may make representations about the application to the General Manager,
by writing to PO Box 96, Rosny Park, 7018 or by electronic mail to
[email protected]. Representations must be received by Council on or before
18 August 2021.
To enable Council to contact you if necessary, would you please also include a day
time contact number in any correspondence you may forward.
Any personal information submitted is covered by Council’s privacy policy, available
at www.ccc.tas.gov.au or at the Council offices.
SHEET INDEXCOVER SHEETSITE PLAN 1:200SITE PLAN 1:500SOIL & WATER MANAGEMENT PLANGROUND FLOOR PLANELEVATIONSELEVATIONSSECTIONWINDOW & DOOR SCHEDULESCALCULATIONS & SCHEDULESWINDOW FLASHING DETAILS (BRICKWORK)DRAINAGE PLANROOF DRAINAGE PLANELECTRICAL PLANFLOOR COVERINGSKITCHEN DETAILSBATHROOM DETAILSENSUITE DETAILSLAUNDRY DETAILSGENERAL NOTESWET AREA & ENERGY EFFICIENCY NOTES
123456789101112131415161718192021
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
BUILDING INFORMATIONGROUND FLOOR TOP OF WALL HEIGHT(S): 2445mm(CEILING HEIGHT 45mm LOWER THAN TOP OF WALL)ROOF PITCH (U.N.O.): 23.0°ELECTRICITY SUPPLY: SINGLE PHASEGAS SUPPLY: NONE
ROOF MATERIAL: SHEET METALROOF COLOUR: DARKROOF INSULATION: R4.1 BATTS SARKING
WALL MATERIAL: BRICK VENEERWALL INSULATION: R2.0 BATTS WALL WRAP TO ENTIRE HOUSE
FLOOR INSULATION: BIAX X-POD (215MM)
SITE & ENGINEERING INFORMATIONWIND CLASSIFICATION: N3CLIMATE ZONE: ZONE 7 - COOL TEMPERATEWIND REGION: ATERRAIN CATEGORY: TC2SHIELDING FACTOR: NS - NO SHIELDINGTOPOGRAPHIC CLASSIFICATION: T2DESIGN WIND SPEED: 50 m/sec
SITE CLASSIFICATION: ASLAB CLASSIFICATION: TBC
SLAB TO BE 85mm THICK (U.N.O.) WITH REINFORCEMENT TO ENGINEERSSPECIFICATIONS & DETAILS OVER A 200µm WATERPROOF MEMBRANE ON ABED OF FREE DRAINING COARSE SAND (WHERE SPECIFIED)
PROVIDE BRICK CONTROL JOINTS IN ACCORDANCE WITH N.C.C. & AS 3700
ALL TIMBER FRAMING TO BE DESIGNED TO AS1684-2010
SITE LOCATION
LOCATION MAP
No. AMENDMENT SHEET DATE DRAWN CHECKPRELIM PLAN SET - INITIAL ISSUE ALL 2021.01.28 BGU MSP
PRELIM PLAN SET2
THIS DWELLING IS BEING CONSTRUCTED IN A BAL N/A AREA(RESTRICTIONS FOR CONSTRUCTION METHODS/ MATERIALS MAY APPLY REFER NOTES)
- COLORBOND ' MONUMENT MATT'
BA PLAN SET - INITIAL ISSUE W COLOURS, PCV, DA RFI ALL 2021.04.19 RLW MSP3
BA PLAN SET - RESITE & SW TRENCH TO GES DESIGN 2,3,4,6,7,8,12 2021.07.12 RLW -4
BA PLAN SET - SWMP 4 2021.07.15 MSP -5
BA PLAN SET - ADDRESSED COUNCIL RFI 2, 3, 12 2021.07.26 CPO -6
BA PLAN SET - DRAINAGE PLAN UPDATE 2, 3, 12 2021.07.28 RMF -
BA PLAN SET7
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
COVER SHEETSCALES:SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:25 A
MTe
mplat
e Ver
sion:
21.02
0
1 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
RL 20.200FILL 0.280
RL 20.200FILL 0.280RL 20.720
CUT 0.240
RL 20.800CUT 0.320
RL 20.800CUT 0.320 PAD RL 20.480
23,608
TAP7,983
9,467
13,721
10,277
5,500
15,306
11,937
41,307
29,432
26,910
450x450 GRATED PVCPIT CONNECTED TOSTORMWATERRETENTION SYSTEM
DUAL-PURPOSE SEPTIC TANK TOENGINEER'S DESIGN (BY WILSON HOMES)
24m² PRIVATE OPEN SPACE @MAX 10% GRADIENT.
COMPLIANT WITH 12.4.3 (A2)
PROPOSEDRESIDENCEFFL 20.850
“THIS PLAN AND ASSOCIATED DIGITAL MODEL IS PREPARED FOR Wilson Homes FROM A COMBINATION OF FIELD SURVEY AND EXISTING RECORDS FOR THE PURPOSE OF DESIGNING NEWCONSTRUCTIONS ON THE LAND AND SHOULD NOT BE USED FOR ANY OTHER PURPOSE.
THE TITLE BOUNDARIES AS SHOWN ON THIS PLAN WERE NOT MARKED AT THE TIME OF THE SURVEY AND HAVE BEEN DETERMINED BY PLAN DIMENSIONS ONLY AND NOT BY FIELD SURVEY. NOMEASUREMENTS OR OFFSETS ARE TO BE DERIVED BETWEEN THE FEATURES ON THIS PLAN AND THE BOUNDARY LAYER. THE RELATIONSHIP BETWEEN THE FEATURES IN THIS MODEL AND THEBOUNDARY LAYERS CANNOT BE USED FOR ANY SET OUT PURPOSES OR TO CONFIRM THE POSITION OF THE TITLE BOUNDARIES ON SITE.DUE TO THE NATURE OF THE TITLE BOUNDARY INFORMATION, IF ANY STRUCTURES ARE DESIGNED ON OR NEAR A BOUNDARY WE WOULD RECOMMEND A RE-MARK SURVEY BE COMPLETEDAND LODGED WITH THE LAND TITLES OFFICE TO SUPPORT THE BOUNDARY DEFINITION.
SERVICES SHOWN HAVE BEEN LOCATED WHERE VISIBLE BY FIELD SURVEY. SERVICES DENOTED AS BEING “PER DBYD ONLY” ARE APPROXIMATE AND FOR ILLUSTRATIVE PURPOSES ONLY.PRIOR TO ANY DEMOLITION, EXCAVATION OR CONSTRUCTION ON THE SITE, THE RELEVANT AUTHORITY SHOULD BE CONTACTED FOR POSSIBLE LOCATION OF FURTHER UNDERGROUNDSERVICES AND DETAILED LOCATIONS OF ALL SERVICES.
IF SUBSEQUENT DESIGN IS INTENDED FOR CONSTRUCTION SETOUT, FUTURE SURVEYING SETOUT COSTS ARE INCREASED IF THE DIGITAL DATA PROVIDED IS ROTATED, SCALED OR MOVED.
THIS NOTE FORMS AN INTEGRAL PART OF THE PLAN/DATA. ANY REPRODUCTION OF THIS PLAN/MODEL WITHOUT THIS NOTE ATTACHED WILL RENDER THE INFORMATION SHOWN INVALID.
1,752m²LOT 15
55.21
38.50
55.63
6.00
13.49
11.28
20.24
19.88
19.85
19.72
19.56
Pard
alote
Clos
e
BitumenDriveway
TBM SH nail inbitumen drivewayRL=20.70
CPRL Peg=19.64RL Ground=19.57
hinge
d join
t fenc
e 30y
rs±
19.80
20.00
20.2020.40
20.40
20.20
20.60
20.80
4.0m
REAR
SET
BACK
LINE
4.5m
FRON
TAGE
SETB
ACK
LINE
1.5m SIDE SETBACK LINE
1.5m SIDE SETBACK LINE
P1
P2FI
LLCUT
CPRL
Peg
=20.3
2RL
Gro
und=
20.24
APPROX. S&P EXPOSED AGG D'WAYBY BUILDER66m² TOTAL
(66m² TO BDY)
SUBSURFACE IRRIGATION AREA TOENGINEER'S DESIGN (BY WILSON HOMES)
100% RESERVE AREA
POLY WATER TANK (BYWILSON HOMES)
RL 20.208FILL 0.272
RL 20.800CUT 0.320
RL 20.590CUT 0.110
1:2 FILL BATTER ( 1000mm MIN.OFFSET FROM DWELLING)
1:2 CUT BATTER (1600mm MIN.OFFSET FROM DWELLING)
STORMWATER RETENTIONTRENCH SYSTEM TO ENGINEER'SDESIGN (BY WILSON HOMES)
LOT SIZE: 1,752m²HOUSE: 149.70m²SITE COVERAGE: 8.5%
ZONE: 12.0 LOW-DENSITY RESIDENTIAL250 DISTANCE FROM CALM MARINE (SHELLY BEACH)
30° EAST30° WEST
N
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FOR ALLBUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
WIND CLASSIFICATIONWITHIN 1 KM. OFBREAKING SALT WATERWITHIN 100 M. OF SALTWATER
N3
NO
NO
MINIMUM AHD FLOORLEVEL APPLICABLE NO
SURVEY AREA NEWLATITUDE 0° 00' 00" SLONGITUDE 0° 00' 00" E
APPROX. IMPORT/EXPORT FILLCUT VOLUME 21.02m³FILL VOLUME 23.37m³DIFFERENCE 2.35m³
EVEN CUT & FILL
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
SITE PLAN 1:200SCALES:
1:200SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:25 A
MTe
mplat
e Ver
sion:
21.02
0
2 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
RL 20.200FILL 0.280
RL 20.200FILL 0.280RL 20.720
CUT 0.240
RL 20.800CUT 0.320
RL 20.800CUT 0.320 PAD RL 20.480
23,608
TAP7,983
9,467
13,721
10,277
5,500
15,306
11,937
41,307
29,432
26,910
450x450 GRATED PVCPIT CONNECTED TOSTORMWATERRETENTION SYSTEM
DUAL-PURPOSE SEPTIC TANK TOENGINEER'S DESIGN (BY WILSON HOMES)
24m² PRIVATE OPEN SPACE @MAX 10% GRADIENT.
COMPLIANT WITH 12.4.3 (A2)
PROPOSEDRESIDENCEFFL 20.850
“THIS PLAN AND ASSOCIATED DIGITAL MODEL IS PREPARED FOR Wilson Homes FROM A COMBINATION OF FIELD SURVEY AND EXISTING RECORDS FOR THE PURPOSE OF DESIGNING NEWCONSTRUCTIONS ON THE LAND AND SHOULD NOT BE USED FOR ANY OTHER PURPOSE.
THE TITLE BOUNDARIES AS SHOWN ON THIS PLAN WERE NOT MARKED AT THE TIME OF THE SURVEY AND HAVE BEEN DETERMINED BY PLAN DIMENSIONS ONLY AND NOT BY FIELD SURVEY. NOMEASUREMENTS OR OFFSETS ARE TO BE DERIVED BETWEEN THE FEATURES ON THIS PLAN AND THE BOUNDARY LAYER. THE RELATIONSHIP BETWEEN THE FEATURES IN THIS MODEL AND THEBOUNDARY LAYERS CANNOT BE USED FOR ANY SET OUT PURPOSES OR TO CONFIRM THE POSITION OF THE TITLE BOUNDARIES ON SITE.DUE TO THE NATURE OF THE TITLE BOUNDARY INFORMATION, IF ANY STRUCTURES ARE DESIGNED ON OR NEAR A BOUNDARY WE WOULD RECOMMEND A RE-MARK SURVEY BE COMPLETEDAND LODGED WITH THE LAND TITLES OFFICE TO SUPPORT THE BOUNDARY DEFINITION.
SERVICES SHOWN HAVE BEEN LOCATED WHERE VISIBLE BY FIELD SURVEY. SERVICES DENOTED AS BEING “PER DBYD ONLY” ARE APPROXIMATE AND FOR ILLUSTRATIVE PURPOSES ONLY.PRIOR TO ANY DEMOLITION, EXCAVATION OR CONSTRUCTION ON THE SITE, THE RELEVANT AUTHORITY SHOULD BE CONTACTED FOR POSSIBLE LOCATION OF FURTHER UNDERGROUNDSERVICES AND DETAILED LOCATIONS OF ALL SERVICES.
IF SUBSEQUENT DESIGN IS INTENDED FOR CONSTRUCTION SETOUT, FUTURE SURVEYING SETOUT COSTS ARE INCREASED IF THE DIGITAL DATA PROVIDED IS ROTATED, SCALED OR MOVED.
THIS NOTE FORMS AN INTEGRAL PART OF THE PLAN/DATA. ANY REPRODUCTION OF THIS PLAN/MODEL WITHOUT THIS NOTE ATTACHED WILL RENDER THE INFORMATION SHOWN INVALID.
1,752m²LOT 15
55.21
38.50
55.63
6.00
13.49
11.28
20.24
19.88
19.85
19.72
19.56
Pard
alote
Clos
eBitumenDriveway
TBM SH nail inbitumen drivewayRL=20.70
CPRL Peg=19.64RL Ground=19.57
hinge
d join
t fenc
e 30y
rs±
19.80
20.00
20.2020.40
20.40
20.20
20.60
20.80
4.0m
REAR
SET
BACK
LINE
4.5m
FRON
TAGE
SETB
ACK
LINE
1.5m SIDE SETBACK LINE
1.5m SIDE SETBACK LINE
P1
P2
FILLCU
T
CPRL
Peg
=20.3
2RL
Gro
und=
20.24
APPROX. S&P EXPOSED AGG D'WAYBY BUILDER66m² TOTAL
(66m² TO BDY)
SUBSURFACE IRRIGATION AREA TOENGINEER'S DESIGN (BY WILSON HOMES)
100% RESERVE AREA
POLY WATER TANK (BYWILSON HOMES)
RL 20.208FILL 0.272
RL 20.800CUT 0.320
RL 20.590CUT 0.110
1:2 FILL BATTER ( 1000mm MIN.OFFSET FROM DWELLING)
1:2 CUT BATTER (1600mm MIN.OFFSET FROM DWELLING)
STORMWATER RETENTIONTRENCH SYSTEM TO ENGINEER'SDESIGN (BY WILSON HOMES)
30° EAST30° WEST
N
LOT SIZE: 1,752m²HOUSE: 149.70m²SITE COVERAGE: 8.5%
ZONE: 12.0 LOW-DENSITY RESIDENTIAL250 DISTANCE FROM CALM MARINE (SHELLY BEACH)
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FOR ALLBUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
WIND CLASSIFICATIONWITHIN 1 KM. OFBREAKING SALT WATERWITHIN 100 M. OF SALTWATER
N3
NO
NO
MINIMUM AHD FLOORLEVEL APPLICABLE NO
SURVEY AREA NEWLATITUDE 0° 00' 00" SLONGITUDE 0° 00' 00" E
APPROX. IMPORT/EXPORT FILLCUT VOLUME 21.02m³FILL VOLUME 23.37m³DIFFERENCE 2.35m³
EVEN CUT & FILL
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
SITE PLAN 1:500SCALES:
1:500SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:25 A
MTe
mplat
e Ver
sion:
21.02
0
3 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
30° EAST30° WEST
N
STABILISED ENTRYAND EXIT POINT
DIVERSION DRAIN
EXTENT OF CLEARANCE OR DISTURBANCE
55.21
55.63
6.00
13.49
11.28
20.24
19.88
Pard
alote
Clos
e
BitumenDriveway
TBM SH nail inbitumen drivewayRL=20.70
20.00
20.2020.40
20.40
20.20
20.60
20.80PROPOSED DWELLING
ALL RUNOFF AND SEDIMENTCONTROL STRUCTURES WILL BEINSPECTED EACH WORKING DAYAND MAINTAINED IN A FUNCTIONALCONDITION.
ALL VEGETATION OUTSIDE THEBUILDING ZONE WILL BEMAINTAINED.
SANDSTOCKPILEMA
TERI
ALST
ORAG
E AR
EA
HARDWASTEBRICK
CONCRETE
BINBLOWABLERUBBISH
TOP SOILSTOCKPILE
EXISTINGVEGETATION OR
TURF STRIPE
EXISTINGVEGETATION OR
TURF STRIPE
APPROX. S&P EXPOSED AGG D'WAYBY BUILDER66m² TOTAL
(66m² TO BDY)
ENTRY/ EXIT PAD BUND
50 x 25 x 1000STAKE OR
STAR PICKETMEMBRANE TO BE BIDIM U24OR APPROVED EQUIVALENT
BURY APPROXIMATELY 150mmOF MEMBRANE AND TEMPORARILYBACKFILL TO RESTORE PRIORNATURAL SURFACE LEVEL
SANDBAGS OVERLAPONTO KERB
GAP BETWEEN SANDBAGSACTS AS SPILLWAY
THREE LAYERS OFSANDBAGS WITHENDS OVERLAPPED
EXISTINGROADWAY
BERM (0.3mMIN. HEIGHT)
GEOTEXTILEFABRIC
50-70mmGRAVEL
SILT FENCING DETAILSANDBAG KERB INLETSEDIMENTATION TRAP
R U N O F F
600
150
NATURAL SURFACEDOWNHILL OF MEMBRANENOT TO BE DISTURBED
R U N O F F
TEMPORARY CONSTRUCTION EXIT
0.2m
MIN. LENGTH 15m
RUNOFF FROM PADDIRECTED TO SEDIMENTATION TRAP
CONSTRUCTION SITE
ALL VEGETATION OUTSIDE THE BUILDINGZONE WILL BE MAINTAINED.
OWNER TO STABILISE THE SITE ONCOMPLETION OF THE BUILD WITH TURFLAWNS, GRASS SEEDS, NATIVE GROUNDCOVERS AND/ OR MULCH SPREAD TO ADEPTH OF 75-100mm
THE FOLLOWING IS A STANDARDAPPROACH. SEDIMENT AND EROSIONCONTROL MEASURES WILL BE REVIEWEDPRIOR TO COMMENCING WORK ANDINSTALLED BASED ON THE OUTCOME OFTHAT REVIEW.
NOTES:1. ALL EROSION AND SEDIMENT CONTROLSTRUCTURES TO BE INSPECTED EACHWORKING DAY AND MAINTAINED IN GOODWORKING ORDER.2. ALL GROUND COVER VEGETATIONOUTSIDE THE IMMEDIATE BUILDING AREATO BE PRESERVED DURING THE BUILDINGPHASE.3. ALL EROSION AND SEDIMENT CONROLMEASURES TO BE INSTALLED PRIOR TOCOMMENCEMENT OF MAJOREARTHWORKS.4. STOCKPILES OF CLAYEY MATERIAL TOBE COVERED WITH AN IMPERVIOUS SHEET.5. ROOF WATER DOWNPIPES TO BECONNECTED TO THE PERMAMENTUNDERGROUND STORMWATER DRAINAGESYSTEM AS SOON AS PRACTICAL AFTERTHE ROOF IS LAID.
6. DIVERSION DRAINS ARE TO BECONNECTED TO A LEAGAL DISCHARGEPOINT (COUNCIL STORMWATER SYSTEM,WATERCOURSE OR ROAD DRAIN).7. SEDIMENT RETENTION TRAPSINSTALLED AROUND THE INLETS TO THESTORMWATER SYSTEM TO PREVENTSEDIMENT & OTHER DEBRIS BLOCKINGTHE DRAINS.
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
SOIL & WATER MANAGEMENT PLANSCALES:
1:200SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:25 A
MTe
mplat
e Ver
sion:
21.02
0
4 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
1675
WS
BREAKFAST BAR
A0906
W05
AF1516
W06
SF2158x1470
D02
AF15
16
W09
AF1516
W10
FS2124
D03
A150
6
W11
820
#770
770
820
1200
SS
820
1000 SS
SELECT2 x 820 CSD 2 x
820 S
MART
ROBE
2 x 820 SMARTROBE
2 x 820 SMARTROBE
620
2 x 820 SMARTROBE
820
OFF FFL903SILL ALUMAFA720x2170
W13
A/F1
809
W01
A/F1
809
W02
)13
76 (
2097
x920
D01
A/F1
809
W03
A/F1
809
W04
A0906
W07
AF1516
W08
#720
820
820
OFF FFL903SILL ALUMF720x2170
W12
FH
FH(G-ROBE-0007)
970
900
900WM
2155BULKHEAD
OVER
668
900
900
2155 BULKHEADOVER
TANK
WAT
ERYA
RD T
AP
AJCDP
HWS
CDP
CDP
CDPCDP
AJ
AJ AJ
AJ
AJ
AJ
AJ
AJ
AJ
AJ
TANK WATERYARD TAP
2401,700 ROBE901,240901,020906,600 DINING/ FAMILY901,910 LINEN902,000 ENTRY2402,230 PORCH
2404,140 BED 4906,600 DINING/ FAMILY904,000 ENTRY240
2403,030 BED 3904,660 HALL901,170901,700 ROBE901,910 WIR903,630 MASTER240600
901,860 BATH90920 WC
901,700 LDRY
902,960 BED 2901,910 ENS90
240
1,460
PTY
901,0
20
REF
903,2
40 D
ININ
G90
510
ROBE
902,7
50 B
ED 2
240
450
240
2,100
ENS
901,6
10 W
IR90
620
LN90
1,200
EN
TRY
903,9
00 LI
VING
240
240
3,470
MAS
TER
901,7
90 E
NTRY
90
240
2,260
LDRY
901,0
0090
3,630
FAM
ILY24
02,2
70
240
1,600
WC
902,1
10 H
ALL
90
240
1,700
ROBE
901,2
4090
1,600
902,7
10 B
ATH
240
240
3,950
BED
390
3,030
BED
424
0
600 3,720 2,390 4,450 3,350 3,120
450
7,550
2,270
450
3,950
5,870
10,27
0 O/A
17,630 O/A
600 1,630 8,200 7,200
3,1203501,5704706103501,4708301,5705809506108303,720600
2403,540 BED 490510ROBE
902,880 FAMILY903,630 KITCHEN904,000 LIVING240
2402,980 KITCHEN90560PTY
90
1,1901,5702,0302,4106452,1702,0452,1701,170
450
240
3,350
BED
290
5,900
DIN
ING
/ KIT
CHEN
240
240
3,350
BED
390
510
ROBE
90
450
1,190
1,570
4,790
590
610
1,070
450
470
850
1,310
850
470
1,376
629
850
1,695
850
470
600
1,745
470
3,270
470
350 1,880
1,630 240
710
600
1,790
600
1,790
600
1,790
45045
0
1,1801,180
590
450
650 850 2,130 90 260
901,0
2090
1,270
9010
0
450
450
300 MIN.
150
A 8A 8
LOCALLY GRADE TOMAX. 190mm BELOW FFL
LOCALLY GRADE TO MAX.190mm BELOW FFL
OUTDOOR HEATPUMP UNIT
720h SPLASHBACK WINDOW TO BECONSTRUCTED IN ACCORDANCEWITH G-WIND-KIT001
INDO
OR H
EAT
PUMP
UNI
T
WATERPOINTTO REF
70mmSETDOWN
SALT
& P
EPPE
R EX
POSE
DAG
GREG
ATE
TO P
ORCH
SMALL SHAMPOO RECESS (G-WETA-TILE01)
470 x
350m
m BR
ICK
PIER
WIT
HFA
CE B
RICK
FIN
ISH
AND
90 x
90mm
GAL
. SHS
TO
CORE
BEAM
S OV
ER T
OMA
NUF.
SPE
CS
SMALL SHAMPOO RECESS (G-WETA-TILE01)
MB
250L
KITCHEN
MASTERSUITE
WIR
ENS
BED 2
ROBE
LDRY
BED 3
ROBE
BED 4
ROBE
DINING FAMILY
PANT
RY
LIVING
ENTRY
LINEN
PORCH(PB)
BATH
REF
FRAMED BULKHEAD TO KITCHENCUPBOARDS 2287 OFF FFL AND 630FROM WALL (D-FRAM-BULK008)
G-CA
BI-K
IT01
0CA
B UN
IT D
2287
BUL
KHEA
D TO
FRID
GE S
PACE
1000 900
1,000
600
30° EAST30° WEST
N
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FOR ALLBUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
CHARGED DOWNPIPE DIRECTED TO TANK STANDARD DOWNPIPE DIRECTED TO STORMWATER DISCHARGE
CDP
SDP
ALL GROUND FLOOR BULKHEAD ANDSQUARE SET OPENING FRAMES TO BE 2155ABOVE FFL UNLESS NOTED OTHERWISE
REFER TO WINDOW & DOOR SCHEDULESFOR FULL DETAILS OF ALL WINDOWS ANDDOORS
FINAL WINDOW AND EXTERIOR DOORLOCATIONS MAY BE ADJUSTED ON SITE TOSUIT BRICKWORK GAUGE
UNLESS NOTED OTHERWISEALL ROOMS ARE REFERENCEDAS FOLLOWS:
ABD
C
TOTAL FLOOR AREASLIVINGPORCH
144.195.51
149.70 m²
ALL DIMENSIONS ARE FRAME DIMENSIONSGAS
GAS BAYONET
AJ BRICK ARTICULATION JOINT
3D DENOTES DRAWER SIDE
L.B.W LOAD BEARING WALL
THIS DOOR OPENS FIRST
SMOKE ALARM
LIFT OFF HINGE#
FLOOR PLAN LEGEND
MECHANICAL VENTILATIONSWITCHED TO LIGHT
WATER POINT
HOB SPOUT / WALL SPOUTHS / WS
WP FRIDGE WATER POINT
FACE BRICK / COMMON BRICK
BAG & PAINT / RENDER
SOUND INSULATION
REFER 'BRICK COURSING AND WINDOWFLASHING DETAIL' FOR BRICK COURSING &WINDOW FLASHING DETAILS
W12, W13, D03 COMPLIANT WITH PART 12.4.4(A1) SUNLIGHT AND OVERSHADOWING
"SMALL" 470 x 380mm"MEDIUM" 800 x 380mm"LARGE" 1500 x 380mm
WIDTH548mm878mm1578mm
STRUCTURAL DIMENSIONSHEIGHT446mm446mm446mm
SHAMPOO RECESS SIZE
REFER WILSON HOMES' DETAIL G-WETA-TILE01 FORFURTHER DETAIL PRIOR TO INSTALLATION.
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
GROUND FLOOR PLANSCALES:
1:100SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:25 A
MTe
mplat
e Ver
sion:
21.02
0
5 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
23°
RL 20.850 - GROUND FLOOR
RL 23.295 - TOP OF WALL
3,000
5,500
W01 W02 D01 W03 W04
LINE OF NGL
1:2 CUT BATTER BUILD
ING ENVELOPE
BUILDING ENVELOPE
ARTICULATED FACEBRICKWORK
470 x 710mm BRICK PIER WITHFACE BRICK FINISH AND 90 x
90mm GAL. SHS TO CORE
470 x 710mm BRICK PIER WITHFACE BRICK FINISH AND 90 x90mm GAL. SHS TO CORE
ENTRY DOOR WITHGLASS SIDELIGHT
COLORBOND CORRUGATED /CUSTOM ORB METALROOFING + SARKING
RL 20.850 - GROUND FLOOR
RL 23.295 - TOP OF WALL
3,000
5,500
278
279
W11W09
LINE OF NGL
BUILDING ENVELO
PE
BUILDING ENVELOPE
1:2 FILL BATTER
ARTICULATED FACEBRICKWORK
COLORBOND CORRUGATED /CUSTOM ORB METALROOFING + SARKING
HOT WATER SERVICE
WINDOW TYPE LEGEND
AWNING DOUBLEHUNG FIXED LOUVRE SLIDINGCLEAR OBSCURE ACOUSTIC LOW-E TONED
GLASS TYPE LEGEND
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FORALL BUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
SH = SNAP HEADER SILL
WEST ELEVATIONScale: 1:100
EAST ELEVATIONScale: 1:100
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
ELEVATIONSSCALES:
1:100SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:26 A
MTe
mplat
e Ver
sion:
21.02
0
6 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
RL 20.850 - GROUND FLOOR
RL 23.295 - TOP OF WALL
8,500
903
279
1:2 CUT BATTER
W10 D03
W12 W13
LOCALLY GRADE TO MAX.190mm BELOW FFL
720h SPLASHBACK WINDOW TO BECONSTRUCTED IN ACCORDANCEWITH G-WIND-KIT001LINE OF NGL
BUILDING ENVELOPE
BUI
LDIN
G EN
VELO
PE
1:2 FILL BATTER
470 x 710mm BRICKPIER WITH FACE BRICKFINISH AND 90 x 90mmGAL. SHS TO CORE
COLORBOND CORRUGATED /CUSTOM ORB METALROOFING + SARKING
ARTICULATED FACEBRICKWORK
ALUMINIUM SLIDING DOOR
23°
RL 20.850 - GROUND FLOOR
RL 23.295 - TOP OF WALL
8,500
1,250
280
W05 W06 D02 W07 W08
1:2 CUT BATTER
LOCALLY GRADE TO MAX.190mm BELOW FFL
LINE OF NGL
BUILDING ENVELOPE
BUI
LDIN
G EN
VELO
PE
1:2 FILL BATTER
470 x 710mm BRICK PIER WITHFACE BRICK FINISH AND 90 x
90mm GAL. SHS TO CORE
COLORBOND CORRUGATED /CUSTOM ORB METALROOFING + SARKING
ARTICULATED FACEBRICKWORK
ALUMINIUM SLIDING DOOR
ALUMINIUM AWNING WINDOW(OBSCURE GLASS)
SINGLE PHASE METER BOX
HOT WATER SERVICE
WINDOW TYPE LEGEND
AWNING DOUBLEHUNG FIXED LOUVRE SLIDINGCLEAR OBSCURE ACOUSTIC LOW-E TONED
GLASS TYPE LEGEND
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FORALL BUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
SH = SNAP HEADER SILL
NORTH ELEVATIONScale: 1:100
SOUTH ELEVATIONScale: 1:100
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
ELEVATIONSSCALES:
1:100SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:26 A
MTe
mplat
e Ver
sion:
21.02
0
7 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
WINDOW TYPE LEGEND
AWNING DOUBLEHUNG FIXED LOUVRE SLIDINGCLEAR OBSCURE ACOUSTIC LOW-E TONED
GLASS TYPE LEGEND
23°
RL 20.850 - GROUND FLOOR
RL 23.295 - TOP OF WALL
600
450
370
2,445
1,849
4,664
REFER ENGINEERING FORFLOOR AND FOOTING DETAILS
MANUFACTURED TIMBER TRUSSES
PLASTERBOARDCEILING LININGS
PLASTERBOARDWALL LININGS
EXISTING GROUND LEVEL
1:2 CUT BATTER
COLORBOND CORRUGATED / CUSTOMORB METAL ROOFING + SARKING
OVERALL HEIGHT
KITCHENDININGBED 2
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FORALL BUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
SH = SNAP HEADER SILL
SECTION A-AScale: 1:100
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
SECTIONSCALES:
1:100SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:26 A
MTe
mplat
e Ver
sion:
21.02
0
8 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
QTY111411116
CODE1000 SS1200 SS2 x 820 CSD2 x 820 SMARTROBE620720770770820
TYPESQUARE SET OPENINGSQUARE SET OPENINGCAVITY SLIDINGSMARTROBE SLIDINGSWINGINGSWINGINGSWINGINGSWINGINGSWINGING
HEIGHT2,1552,1552,0402,0402,0402,0402,0402,0402,040
WIDTH1,0001,2001,6401,660620720770770820
GLAZINGN/AN/AN/AN/AN/AN/AN/AN/AN/A
ADDITIONAL INFORMATION
SELECT
LIFT-OFF HINGESLIFT-OFF HINGES
ID
D01D02D03
CODEº
2097x920SF2158x1470FS2124
ROOM
ENTRYLDRYFAMILY
HEIGHT
2,0972,1582,158
WIDTH
1,3761,4702,410
AREA(m²)2.893.175.20
11.26 m²
FRAMETYPEALUMINIUMALUMINIUMALUMINIUM
SILL TYPE
SNAP HEADERSNAP HEADERSNAP HEADER
ORIENT.
WSN
GLAZING TYPE
CLEAR, DOUBLE GLAZEDCLEAR, DOUBLE GLAZED, TOUGHENEDCLEAR, DOUBLE GLAZED, TOUGHENED
DOOR TYPE
SWINGINGSLIDINGSLIDING
ADDITIONAL INFORMATION¹
1 x FIXED SIDELIGHT
0, 3 ASSUME LOOKING FROM OUTSIDE 1, 2 ASSUME LOOKING FROM INSIDE
0, 1 ASSUME LOOKING FROM OUTSIDE
QTY TYPE HEIGHT WIDTH AREA (m²)
ID
W01W02W03W04W05W06W07W08W09W10W11W12W13
CODEº
A/F1809A/F1809A/F1809A/F1809A0906AF1516A0906AF1516AF1516AF1516A1506F720x2170AFA720x2170
ROOM
LIVINGLIVINGMASTER SUITEMASTER SUITEENSBED 2WCBATHBED 3BED 4KITCHENKITCHENLIVING
HEIGHT
1,8001,8001,8001,800
8601,460
8601,4601,4601,4601,460
720720
WIDTH
850850850850610
1,570610
1,5701,5701,570
6102,1702,170
PERIMETER
5,3005,3005,3005,3002,9406,0602,9406,0606,0606,0604,1405,7805,780
AREA(m²)1.531.531.531.530.522.290.522.292.292.290.891.561.56
20.33
FRAMETYPEALUMINIUMALUMINIUMALUMINIUMALUMINIUMALUMINIUMALUMINIUMALUMINIUMALUMINIUMALUMINIUMALUMINIUMALUMINIUMALUMINIUMALUMINIUM
SILL TYPE
ANGLEDANGLEDANGLEDANGLEDANGLEDANGLEDANGLEDANGLEDANGLEDANGLEDANGLEDANGLEDANGLED
ORIENT.
WWWWSSSSENENN
GLAZINGAREA (m²)
1.191.191.191.190.351.870.351.871.871.870.641.361.13
16.07
GLAZING TYPE
CLEAR, DOUBLE GLAZEDCLEAR, DOUBLE GLAZEDCLEAR, DOUBLE GLAZEDCLEAR, DOUBLE GLAZEDOBSCURE, DOUBLE GLAZED, TOUGHENEDCLEAR, DOUBLE GLAZEDOBSCURE, DOUBLE GLAZED, TOUGHENEDOBSCURE, DOUBLE GLAZED, TOUGHENEDCLEAR, DOUBLE GLAZEDCLEAR, DOUBLE GLAZEDCLEAR, DOUBLE GLAZEDCLEAR, DOUBLE GLAZED, TOUGHENEDCLEAR, DOUBLE GLAZED
ADDITIONAL INFORMATION¹
BP 600BP 600BP 600BP 600
MP 785
MP 785MP 785MP 785
MP 723-723
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FOR ALLBUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
Manufacturer - Clark WindowsWindow Type Glazing U-Value SHGCAwning Single 6.5 0.67
Double 4.1 0.57Fixed Single 5.8 0.75
Double 3.2 0.67Sliding Single 6.4 0.76
Double 4.2 0.59Fixed Pane Single 5.8 0.75
Double 3.2 0.67Fixed Glass Panel Hinged Door Single 6.0 0.62
Double 4.3 0.55Sliding Door Single 6.1 0.74
Double 3.6 0.66
135 deg. Awning Bay Window Single 6.5 0.67Double 4.1 0.57
135 deg. Sliding Bay Window Single 6.5 0.76Double 4.2 0.59
90 deg. Awning Bay Window Single 6.5 0.67Double 4.1 0.57
90 deg. Sliding Bay Window Single 6.5 0.76Double 4.2 0.59
Bifold Doors Single 6.1 0.61Double 4.4 0.53
NOTE:Windows supplied MUST HAVE Uw better and or equal to stated figures and SHGCwithin +/- 5% of stated figures. Restricted windows to have their openability restrictedas per N.C.C 3.9.2.5.
Stacking Door Single 6.3 0.74Double 3.8 0.66
INTERIOR DOOR SCHEDULE
EXTERIOR DOOR SCHEDULE
WINDOW SCHEDULE
PICTURE / TV RECESS & SQUARE SET WINDOW SCHEDULE
MERBAU
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
WINDOW & DOOR SCHEDULESSCALES:SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:26 A
MTe
mplat
e Ver
sion:
21.02
0
9 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
BUILDING INFORMATIONGROUND FLOOR TOP OF WALL HEIGHT(S): 2445mm(CEILING HEIGHT 45mm LOWER THAN TOP OF WALL)ROOF PITCH (U.N.O.): 23.0°ELECTRICITY SUPPLY: SINGLE PHASEGAS SUPPLY: NONE
ROOF MATERIAL: SHEET METALROOF COLOUR: DARKROOF INSULATION: R4.1 BATTS SARKING
WALL MATERIAL: BRICK VENEERWALL INSULATION: R2.0 BATTS WALL WRAP TO ENTIRE HOUSE
FLOOR INSULATION: BIAX X-POD (215MM)
SITE & ENGINEERING INFORMATIONWIND CLASSIFICATION: N3CLIMATE ZONE: ZONE 7 - COOL TEMPERATEWIND REGION: ATERRAIN CATEGORY: TC2SHIELDING FACTOR: NS - NO SHIELDINGTOPOGRAPHIC CLASSIFICATION: T2DESIGN WIND SPEED: 50 m/sec
SITE CLASSIFICATION: ASLAB CLASSIFICATION: TBC
SLAB TO BE 85mm THICK (U.N.O.) WITH REINFORCEMENT TO ENGINEERSSPECIFICATIONS & DETAILS OVER A 200µm WATERPROOF MEMBRANE ON ABED OF FREE DRAINING COARSE SAND (WHERE SPECIFIED)
PROVIDE BRICK CONTROL JOINTS IN ACCORDANCE WITH N.C.C. & AS 3700
ALL TIMBER FRAMING TO BE DESIGNED TO AS1684-2010
INSULATION SCHEDULEAREAROOF
WALLS (EXT)
WALLS(INTERNAL)
FLOORS
+1 LAYER SISALATION. SISALATION ONLY TO GARAGE
(OR EQUIVALENT) EXCLUDING GARAGE
R2.0 BULK INSULATION (OR EQUIVALENT) TOINTERNAL WALLS ADJACENT TO GARAGE
CLEARANCE IS REQUIRED FOR UNCOMPRESSED INSTALLATION OF BULK INSULATION &TIMBERS SHOULD BE SIZED ACCORDINGLY210mm FOR R4.1 BULK INSULATION210mm FOR R5.0 BULK INSULATION260mm FOR R6.0 BULK INSULATIONTHESE DIMENSIONS ARE NOMINAL AND MAY VARY DEPENDING ON THE TYPE OF INSULATIONTO BE INSTALLED
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
CALCULATIONS & SCHEDULESSCALES:SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:26 A
MTe
mplat
e Ver
sion:
21.02
0
10 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
5
110
110 40 90
90
1920
20
EAVE AS PER PLANS
AS P
ER C
ONST
RUCT
ION
PLAN
S
240
38
2018
FLASHING (ALCOR OR SIMILAR) TO SILL ONLY
WEEP HOLE
FACTORY FITTED TIMBER REVEAL ASPER WINDOW MANUFACTURER'S DETAIL
RAKED SILL
BRICKWORK IN DISTANCE
QUAD STORM MOULD (ALLCORNERS MUST BE MITRED)
EAVE FRAMING AS REQUIRED
TIMBER DROPPERS FROM TRUSSTOP CHORDS AS REQUIRED
SELECTED ROOFING ON BATTENS AS REQUIRED
PLASTERBOARD CEILING
CORNICE AS SELECTED
ARCHITRAVE
ARCHITRAVE
WATER COMPENSATING APRON BY GLAZINGMANUFACTURER
TIMBER FOR SUPPORT ABOVE 1200mmBY BUILDER
PLASTERBOARD LINING
WALL INSULATION AS PERCONSTRUCTION PLANS
WINDOW AS PER CONSTRUCTION PLANSAND TO GLAZING MANUFACTURER'S DETAIL
PACKING AS REQUIRED
TIMBER WINDOW REVEAL
FIXINGS AS REQUIRED
20mm PACKING AS REQUIRED
FIXINGS AS REQUIRED
20mm PACKING AS REQUIRED
WINDOW SILL
HEAD TRIMMER
DROP OFF
SILL TRIMMER
PITC
HING
POIN
T
PITCHINGPOINT
TRUSS BOTTOM CHORD
TRUSS TOP CHORD
INSIDEOUTSIDE
NO. OFBRICKS LENGTH OPENING HEIGHT NO. OF
BRICKS LENGTH OPENING HEIGHT
1 230 250 86 26 6230 6250 2229
1 1 2 350 370 261 2 6350 6370
2 470 490 172 27 6470 6490 2314
21 2 590 610 271 2 6590 6610
3 710 730 257 28 6710 6730 2400
31 2 830 850 281 2 6830 6850
4 950 970 343 29 6950 6970 2486
41 2 1070 1090 291 2 7070 7090
5 1190 1210 429 30 7190 7210 2572
51 2 1310 1330 301 2 7310 7330
6 1430 1450 514 31 7430 7450 2657
61 2 1550 1570 31 1 2 7550 7570
7 1670 1690 600 32 7670 7690 2743
71 2 1790 1810 321 2 7790 7810
8 1910 1930 686 33 7910 7930 2829
81 2 2030 2050 331 2 8030 8050
9 2150 2170 772 34 8150 8170 2914
91 2 2270 2290 341 2 8270 8290
10 2390 2410 857 35 8390 8400 3000
10 1 2 2510 2530 35
1 2
8510
NO
T O
FTEN
REQ
UIR
ED. I
F N
EED
ED A
DD
20
TO L
ENG
TH.
11 2630 2650 943 36 8630 3086
11 1 2 2750 2770 361 2 8750
12 2870 2890 1029 37 8870 3172
12 1 2 2990 3010 371 2 8990
13 3110 3130 1114 38 9110 3257
13 1 2 3230 3250 381 2 9230
14 3350 3370 1200 39 9350 3343
14 1 2 3470 3490 391 2 9470
15 3590 3610 1286 40 9590 3429
15 1 2 3710 3730 401 2 9710
16 3830 3850 1372 41 9830 3514
16 1 2 3950 3970 41 1 2 9950
17 4070 4090 1457 42 10070 3600
17 1 2 4190 4210 421 2 10190
18 4310 4330 1543 43 10310 3686
18 1 2 4430 4450 431 2 10430
19 4550 4570 1629 44 10550 3772
19 1 2 4670 4690 441 2 10670
20 4790 4810 1714 45 10790 3857
201 2 4910 4930 451 2 10910
21 5030 5050 1800 46 11030 3943
21 1 2 5150 5170 461 2 11150
22 5270 5290 1886 47 11270 4029
221 2 5390 5410 471 2 11390
23 5510 5530 1972 48 11510 4114
231 2 5630 5650 481 2 11630
24 5750 5770 2057 49 11750 4200
241 2 5870 5890 491 2 11870
25 5990 6010 2143 50 11990 4286
251 2 6110 6130 100 23990 8572
STANDARD BRICKBRICKWORK DIMENSIONS Bricks per m 2 in wall = 48.5 approx. all dimensions in mm
FORMAT SIZE:240x120x86mm
MANUFACTURING SIZE:230x110x76mm
VERTICAL GAUGE:7 Courses to 600mm
110
240
18 20
SELECTED ALUMINIUM WINDOWFRAME
110mm TIMBER REVEAL AS PERBRADNAMS
SILL
BRICKWORK AS SELECTED
FINE BEAD OF SEALANT
20mm PACKING AS REQUIRED PLASTERBOARD WALLLINING
ARCHITRAVE
INSIDE
OUTSIDE
TYPICAL JAMBDETAIL
90mm TIMBER EXTERNALWALL FRAMING
110
4090
SCREW FIX REVEAL BYCARPENTER AT 600mm CENTRES
NO. OFBRICKS LENGTH OPENING HEIGHT NO. OF
BRICKS LENGTH OPENING HEIGHT
STANDARD BRICKBRICKWORK DIMENSIONS Bricks per m 2 in wall = 48.5 approx. all dimensions in mm
FORMAT SIZE:240x120x86mm
MANUFACTURING SIZE:230x110x76mm
VERTICAL GAUGE:7 Courses to 600mm
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
THIS DWELLING IS BEING CONSTRUCTED IN A BAL N/A AREA(RESTRICTIONS FOR CONSTRUCTION METHODS/ MATERIALS MAY APPLY. REFER TO NOTES)
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
WINDOW FLASHING DETAILS (BRICKWORK)SCALES:SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:26 A
MTe
mplat
e Ver
sion:
21.02
0
11 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
PAD RL 20.480
WCWM
WC
CDP CDP
CDP
CDPCDP
23,608
TAP
APPROX. 2% FALLS
350x350 GRATED PVC PITCONNECTED TO STORMWATER
HEAT PUMP OVERFLOWCONNECTED TO SW
50mm UPVC VENT TO OUTSIDE THROUGHROOF, CONNECTED TO SEWER
450x450 GRATED PVCPIT CONNECTED TOSTORMWATERRETENTION SYSTEM
DUAL-PURPOSE SEPTIC TANK TOENGINEER'S DESIGN (BY WILSON HOMES)
HWS OVERFLOWCONNECTED TO SW
O.R.G. WITH TAP OVER. O.R.G. TO BE MIN150MM BELOW LOWEST SANITARY FIXTURE.
50mm UPVC VENT TOOUTSIDE THROUGH ROOF,CONNECTED TO SEWER
350x350 GRATED PVC PITCONNECTED TO STORMWATER
PROPOSEDRESIDENCEFFL 20.850
55.21
38.50
55.63
6.00
13.49
11.28
20.24
19.88
19.85
19.72
CPRL Peg=19.64RL Ground=19.57
hinge
d join
t fenc
e 30y
rs±
19.80
20.00
20.2020.40
20.40
20.20
20.60
20.80
CPRL
Peg
=20.3
2RL
Gro
und=
20.24
IO
IOIO
IO IO
APPROX. S&P EXPOSED AGG D'WAYBY BUILDER66m² TOTAL
(66m² TO BDY)
SUBSURFACE IRRIGATION AREA TOENGINEER'S DESIGN (BY WILSON HOMES)
100% RESERVE AREA
POLY WATER TANK (BYWILSON HOMES)
100 UPVC PIPE CONNECTED TOSEPTIC SYSTEM. MIN 1% FALLS.
100 UPVC PIPE CONNECTED TORAINWATER TANK. MIN 1% FALLS.
100 UPVC PIPE CONNECTEDTO STORMWATER RETENTIONSYSTEM. MIN 1% FALLS.
RAINWATER OVERFLOW CONNECTEDTO STORMWATER RETENTION TRENCHVIA 100 UPVC PIPE. MIN 1% FALLS.
STORMWATER RETENTIONTRENCH SYSTEM TO ENGINEER'SDESIGN (BY WILSON HOMES)
30° EAST30° WEST
N
WHERE AG DRAIN IS <1.5m FROM FOOTING, THEFOLLOWING ENGINEERING PRINCIPLES AREREQUIRED:
1. AG DRAIN TO BE CAPPED WITH300mm OF CLAY TO PREVENT INGRESS OFSURFACE RUN-OFF UNLESS IT IS UNDER A PAVINGSLAB ETC (AG DRAINS ARE DESIGNED FORREMOVAL OF GROUND WATER, SURFACE WATERSHOULD BE DEALT WITH SEPARATELY). 2. AG DRAIN TO HAVE A MINIMUM 1%TO A GRATED PIT WHICH DRAINS TO THESTORMWATER SYSTEM. 3. INSTALL A GEOTEXTILE FILTERSOCK TO THE SLOTTED DRAIN, AND ENCLOSE THEWHOLE DRAIN IN GEOFABRIC (TO THE UNDERSIDEOF CLAY CAPPING) 4. PROVIDE ADDITIONAL GRATEDPITS/ OR INSPECTION OPENINGS ALONG THELENGTH OF THE AG DRAIN AND AT THE HIGHPOINT TO MAKE THE EFFECT OF A BLOCKAGEVISIBLE AND ENABLE A BLOCKAGE TO BECLEARED.
EMBANKMENT
AG DRAIN @ MIN 1%GRADIENT
CRUSHED ROCK
300mm CLAY CAPPING
GEOTEXTILE FILTER
AG DRAIN DETAIL N.T.S.
IO
DRAINAGE LEGEND
INSPECTION OPENING
SURFACE PIT
STORMWATER LINE100 UPVC FALL @ 1%
SEWERAGE LINE 100 UPVC FALL @ 1%
AG DRAIN
MAINS YARD TAP + ORG
SEPTIC LINE 100 UPVC FALL @ 1%
MAINS YARD TAP
CHARGED STORMWATERLINE 100 UPVC FALL @ 1%
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FOR ALLBUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
CHARGED DOWNPIPE DIRECTED TO TANK STANDARD DOWNPIPE DIRECTED TO STORMWATER DISCHARGE
CDP
SDP
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
DRAINAGE PLANSCALES:
1:200SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:26 A
MTe
mplat
e Ver
sion:
21.02
0
12 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
30° EAST30° WEST
N
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
Downpipe roof calculations (as per AS/NZA3500.3:2015)
Area of roof (including 115mm Slotted Quad Gutter) (m2)
Ac
Ah
221.46
6300
99
3.4
5
Ae
DRI
RequiredDownpipes
Ah x Slope factor (Table 3.4.3.2 from AS/NZS 3500.3:2015)(1.21 for 23° pitch) (m2)
Cross sectional area of 57 x 115 Slotted Quad Gutter (mm2)
Design Rainfall Intensity (determined from Figure E8 fromAS/NZS 3500.3:2015)
Ac / Acdp
64Acdp Catchment area per Downpipe (determined from Figure 3.5(A)from AS/NZS 3500.3:2015) (m2)
DownpipesProvided
183.03
CDP CDP
CDP
CDPCDP
CDP
FALLFALL
CDP
CDP
CDPCDP
FALL
FALL
FALL FALL
FALL
FALL
FALL
FALLFALL
CATCHMENT AREA35.24 m2
CATCHMENT AREA39.41 m2
CATCHMENT AREA35.54 m2
CATCHMENT AREA35.02 m2
CATCHMENT AREA37.82 m2
WHERE DOWNPIPES ARE FURTHERTHAN 1.2m AWAY FROM VALLEYREFER TO N.C.C.3.5.2.5(b)
POSITION AND QUALITY OF DOWNPIPESARE NOT TO BE ALTERED WITHOUTCONSULTATION WITH DESIGNER.
AREA'S SHOWN ARE SURFACE AREAS/CATCHMENT AREAS, NOT PLAN AREAS
THIS DWELLING IS BEING CONSTRUCTED IN A BAL N/A AREA(RESTRICTIONS FOR CONSTRUCTION METHODS/ MATERIALS MAY APPLY REFER NOTES)
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
ROOF DRAINAGE PLANSCALES:
1:100SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:26 A
MTe
mplat
e Ver
sion:
21.02
0
13 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
IC RATED LED DOWNLIGHT (9W)
STANDARD CEILING LIGHT (30W)
WALL LIGHT (30W)
ELECTRICAL LEGEND
2 x FLUORESCENT LIGHT POINT (72W)
2 x SLIM FLUORESCENT LIGHT POINT (28W)
DOUBLE POWERPOINT
SINGLE POWERPOINT
WATERPROOF SINGLE POWERPOINT
WATERPROOF DOUBLE POWERPOINT
FLOODLIGHTF
FAN/HEAT/LIGHT (10W)
MECHANICAL VENTILATION SWITCHED TO LIGHT
TV POINT
NATIONAL BROADBAND NETWORKB
P PAY TV POINT
PHONE POINT
FS
SENSOR
FLUORESCENT LIGHT POINT (36W)
SMOKE ALARM (INTERCONNECTEDWHERE MORE THAN 1)
S
FLOOD LIGHT WITH SENSOR
CEILING FAN
CAT 5 OR 6 DATA SOCKET6
OUTDOOR LED DOWNLIGHT
PRE-WIRE ONLY
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
CDP CDP
CDP
CDPCDP
1,490
OUTDOOR HEATPUMP UNIT
INDO
OR H
EAT
PUMP
UNI
T
MB
1800
DWS
REF
HWS
WMS
CL
MWS
1050
DGPO INSIDEVANITY
1050
1050
1050
B
RH +OVEN
FS
FS
P PENDANT FITTING
SOFFIT VENT
STANDARD OUTDOOR LIGHT
ALL GPOs 300mm OFF FFL UNLESS OTHERWISE NOTEDPROVIDE SINGLE GPOs FOR MW,DW,REF,WMS.
INSTALL ISOLATION SWITCH WITHIN 2m OF COOKTOP
ALL EXHAUSTS (RANGEHOOD, BATHROOM, TASTICS, OR SIMILARMECHANICAL VENTILATION) TO BE VENTILATED TO OUTSIDE AIR VIA THE
EAVES IN ACCORDANCE WITH NCC VOL 2, PART 3.8.7.3.
LED DOWNLIGHTS ARE IC RATED, WITH 90mm DIA CUTOUTS.REFER TO LIGHTING SPECIFICATIONS FOR SELECTION DETAILS.
THIS DWELLING IS BEING CONSTRUCTED IN A BAL N/A AREA(RESTRICTIONS FOR CONSTRUCTION METHODS/ MATERIALS MAY APPLY REFER NOTES)
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
ELECTRICAL PLANSCALES:SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:26 A
MTe
mplat
e Ver
sion:
21.02
0
14 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
SALT & PEPPER EXPOSEDAGGREGATE TO PORCH
KITCHEN
MASTERSUITE
WIR
ENS
BED 2
ROBE
LDRY
BED 3
ROBE
BED 4
ROBE
DINING FAMILY
PANT
RY
LIVING
ENTRY
LINEN
PORCH(PB)
BATH
REF
COVERINGS LEGEND
COVER GRADE CONCRETE UNLESS OTHERWISE NOTED
CARPET
LAMINATE TIMBER
TILE (STANDARD WET AREAS)
NO COVERING
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FORALL BUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
FLOOR TILES SHOWN ON PLAN DO NOTINDICATE THE SIZE OR JOINT LOCATIONSOF THE ACTUAL FLOOR TILES.TIMBER FLOORING SHOWN ON PLAN DOESNOT INDICATE THE BOARD SIZE ORDIRECTION OF THE ACTUAL FLOORING.
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
FLOOR COVERINGSSCALES:
1:100SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:26 A
MTe
mplat
e Ver
sion:
21.02
0
15 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
MWSFCDWS
BREAKFAST BAR
FCFC
FS2124
D03
A150
6
W1162
0
OFF FFL903SILL
ALUMF720x2170
W12
3D (1 CUT+ 2 POT)
3D (1 CUT+ 2 POT)
450
650 850 2,130 90
260
901,0
2090
1,270
9010
0
AB
CD
LOCALLY GRADE TO MAX.190mm BELOW FFL
720h SPLASHBACK WINDOW TO BECONSTRUCTED IN ACCORDANCEWITH G-WIND-KIT001
WATERPOINTTO REF
KITCHENPANT
RY
LIVINGREF
WCWC
FRAMED BULKHEAD TO KITCHENCUPBOARDS 2287 OFF FFL AND 630FROM WALL (D-FRAM-BULK008)
G-CA
BI-K
IT01
0
CAB
UNIT
D
2287
BUL
KHEA
D TO
FRID
GE S
PACE
1000 900
1,000
600
905
MWS DWS
1,826
1,020
REF SPACE
WATERPOINT TO REF,LOCATION TBC ON SITE
905
720
652
720h SPLASHBACK WINDOW TO BECONSTRUCTED IN ACCORDANCEWITH G-WIND-KIT001
BULKHEAD
UBO
CANOPY
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FORALL BUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
DETAILS DEPICTED ON THIS SHEET ARE AREPRESENTATION ONLY. JOINER MAYADJUST CABINETRY AS REQUIRED.
KITCHEN PLANScale: 1:50
ELEVATION CScale: 1:50 ELEVATION D
Scale: 1:50
ELEVATION BScale: 1:50
ELEVATION AScale: 1:50
ALL DIMENSIONS ARE FRAME DIMENSIONS © 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
KITCHEN DETAILSSCALES:
1:50SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:27 A
MTe
mplat
e Ver
sion:
21.02
0
16 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
BULKHEAD
1,100
1,075
MIRROR
MIX
1,000
350
550
150 300
600
1675
WS
#720
820
668
900
900
2155 BULKHEADOVER
AB
CD
BATH
TOWEL RAIL - SINGLE
LEGEND
TR-S
TL
TRH
RSHR
ROSE
ELBW
MIX
HT
CT
HS
WS
TOWEL LADDER
TOILET ROLL HOLDER
RAIL SHOWER
SHOWER ROSESHOWER ELBOWCONNECTIONMIXER TAP
HOT TAP
COLD TAP
HOB SPOUT
WALL SPOUT
SC STOP COCK
SHELF
ROBE HOOK
SHLF
RH
TOWEL RINGRNG
SHAMPOO RECESSSR
TR-D TOWEL RAIL - DOUBLE
TH TOWEL HOLDER
TR TOWEL RACK
TMB TUMBLER HOLDER
SOAP HOLDERSOAP
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FORALL BUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
DETAILS DEPICTED ON THIS SHEET ARE AREPRESENTATION ONLY
ELEVATION CScale: 1:50
ELEVATION DScale: 1:50
ELEVATION BScale: 1:50
ELEVATION AScale: 1:50
BATHROOM PLANScale: 1:50
ALL DIMENSIONS ARE FRAME DIMENSIONS © 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
BATHROOM DETAILSSCALES:
1:50SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:27 A
MTe
mplat
e Ver
sion:
21.02
0
17 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
700
700
BULKHEAD
MIRROR
1,000
350
550
150 300
600
173
1,100
#770
970
900
900
2155BULKHEAD
OVER
AB
CDENS
TOWEL RAIL - SINGLE
LEGEND
TR-S
TL
TRH
RSHR
ROSE
ELBW
MIX
HT
CT
HS
WS
TOWEL LADDER
TOILET ROLL HOLDER
RAIL SHOWER
SHOWER ROSESHOWER ELBOWCONNECTIONMIXER TAP
HOT TAP
COLD TAP
HOB SPOUT
WALL SPOUT
SC STOP COCK
SHELF
ROBE HOOK
SHLF
RH
TOWEL RINGRNG
SHAMPOO RECESSSR
TR-D TOWEL RAIL - DOUBLE
TH TOWEL HOLDER
TR TOWEL RACK
TMB TUMBLER HOLDER
SOAP HOLDERSOAP
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FORALL BUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
DETAILS DEPICTED ON THIS SHEET ARE AREPRESENTATION ONLY
ELEVATION CScale: 1:50
ELEVATION DScale: 1:50
ELEVATION BScale: 1:50ELEVATION A
Scale: 1:50
ENSUITE PLANScale: 1:50
ALL DIMENSIONS ARE FRAME DIMENSIONS © 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
ENSUITE DETAILSSCALES:
1:50SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:27 A
MTe
mplat
e Ver
sion:
21.02
0
18 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
WMS
WMS
D02
820
WM
AB
CD
LDRY
TOWEL RAIL - SINGLE
LEGEND
TR-S
TL
TRH
RSHR
ROSE
ELBW
MIX
HT
CT
HS
WS
TOWEL LADDER
TOILET ROLL HOLDER
RAIL SHOWER
SHOWER ROSESHOWER ELBOWCONNECTIONMIXER TAP
HOT TAP
COLD TAP
HOB SPOUT
WALL SPOUT
SC STOP COCK
SHELF
ROBE HOOK
SHLF
RH
TOWEL RINGRNG
SHAMPOO RECESSSR
TR-D TOWEL RAIL - DOUBLE
TH TOWEL HOLDER
TR TOWEL RACK
TMB TUMBLER HOLDER
SOAP HOLDERSOAP
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
REFER TO SHEET 1 (COVER SHEET) FORALL BUILDING INFORMATION REGARDING:- SUSTAINABILITY REQUIREMENTS- SITE CLASSIFICATION- GENERAL BUILDING INFORMATION
DETAILS DEPICTED ON THIS SHEET ARE AREPRESENTATION ONLY
ELEVATION CScale: 1:50
ELEVATION DScale: 1:50
ELEVATION BScale: 1:50
ELEVATION AScale: 1:50
LAUNDRY PLANScale: 1:50
ALL DIMENSIONS ARE FRAME DIMENSIONS © 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
LAUNDRY DETAILSSCALES:
1:50SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:27 A
MTe
mplat
e Ver
sion:
21.02
0
19 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
ELECTRICAL- EXHAUST FAN TO COMPLY WITH CURRENT N.C.C. PART 3.8.5.2
SECTION C
- EXHAUST FANS TO BE SEALED AND DUCTED TO OUTSIDE OFDWELLING IN ACCORDANCE WITH NCC VOL 2, PART 3.8.7.3 AND3.8.7.4
- IF VENTING OCCURS DIRECTLY THROUGH WALLS/ROOFADJACENT TO FAN, THEN UNIT REQUIRES SELF CLOSINGBAFFLES TO BE CLASSIFIED AS A SEALED UNIT
- ELECTRICIAN IS TO ENSURE THAT ALL GPO'S IN WET AREASMEET ALL STANDARD AND CODE REQUIREMENTS - ALL GPO'STO BE 300mm FROM FFL UNLESS NOTED OTHERWISE
GENERAL- BUILDER TO VERIFY ALL DIMENSIONS AND LEVELS ON SITE
PRIOR TO COMMENCEMENT OF WORK
- ALL WORK TO BE CARRIED OUT IN ACCORDANCE WITH THENATIONAL CONSTRUCTION CODE (N.C.C.)
- INTERNAL DIMENSIONS ARE TO WALL FRAMING ONLY AND DONOT INCLUDE WALL LININGS
SITE WORKS- CUT AND FILL BATTERS ARE INDICATIVE ONLY. BATTER TO
COMPLY WITH THE N.C.C. TABLE 3.1.1.1
- ALL CUTS AND FFL'S SHOWN (DA DRAWINGS) ARE SUBJECT TOENGINEERING ADVICE ONCE A SATISFACTORY SOIL TEST HASBEEN RECEIVED AND REVIEWED
- ALL EMBANKMENTS THAT ARE LEFT EXPOSED MUST BESTABILISED WITH VEGETATION OR SIMILAR TO PREVENTEROSION
- EMBANKMENTS CANNOT EXCEED 2.0m IN HEIGHT WITHOUTTHE AID OF RETAINING WALLS OR OTHER APPROVED TYPESOF SOIL RETAINING METHODS
- ALL UNPROTECTED EMBANKMENTS MUST COMPLY WITH THESLOPE RATIOS FOR SOIL TYPE IN TABLE 3.1.1.1 OF THE N.C.C.
MASONRY- ALL MASONRY TO BE CONSTRUCTED IN ACCORDANCE WITH
AS3700
- EXTERNAL WALLS TO BE 110mm BRICKWORK UNLESS NOTEDOTHERWISE
- MORTAR MIXED @ 1:1:6 CEMENT:LIME:SAND UNLESS STATEDOTHERWISE BY ENGINEER
- DAMP-PROOF COURSE IN ALL PERIMETER WALLS CUT INTOEXTERNAL WALLS BELOW FLOOR LEVEL WITH WEEP HOLES @1200 CTRS IN ACCORDANCE WITH AS2904
- VERTICAL ARTICULATION JOINTS TO BE PROVIDED @ 6m MAX.CTRS FOR UNREINFORCED MASONARY WALLS EXCEPTWHERE BUILT ON CLASS A OR S SOIL AND SPACED AS PERAS3700 SECTION 12.6.4. WILSON HOMES REQUEST THAT @ 5MCTRS.
- WHERE NECESSARY, STEEL LINTELS ARE TO BE PROVIDED INACCORDANCE WITH AS4100 AND AS3700a
SOIL TYPE /CLASSIFICATION
EMBANKMENT OF SLOPE
COMPACTED FILL CUT
STABLE ROCK (A)
SAND (A)
SILT (P)
FIRM CLAY
SOFT CLAY
SOFT SOILS (P)
2 : 3 8 : 1
1 : 2 1 : 2
1 : 4 1 : 4
1 : 2 1 : 1
NOT SUITABLE 2 : 3
NOT SUITABLE NOT SUITABLE
WET AREAS- WALLS TO WET AREAS TO BE FINISHED WITH WET AREA
PLASTERBOARD
- COMPLIANCE WITH N.C.C. TABLE 3.8.1.1 AND AS3740
- ALL UNENCLOSED SHOWERS ABOVE BATHS TO HAVE MINIMUM900mm SHOWER SCREEN OR FLOORWASTE WITHIN 1500mm OFSHOWER CONNECTION AS PER AS3740
TIMBER FRAMING- ALL WORK TO BE CARRIED OUT IN ACCORDANCE WITH THE
CURRENT N.C.C.
- ALL TIMBER FRAMING TO BE CARRIED OUT IN ACCORDANCEWITH AS1684
- MGP10 PINE FRAMING OR F17 SOLID AND FINGER JOINEDFRAMING TO ALL STRUCTURAL COMPONENTS. 90 x 35mmFRAMING TO INTERNAL AND EXTERNAL WALLS. TIMBERCOMPOSITE ENGINEERED ROOF TRUSSES WITH HARDWOODAND MGP COMPONENTS
- GALVANISED WALL TIES TO MASONRY @ 450 CTRSHORIZONTALLY AND 600 CTRS VERTICALLY, WITH SPACINGREDUCED BY 50% AROUND OPENINGS
BRACING / LINTELS- WALL BRACING AS PER AS1684-2 2010 AND AS1170 WIND
LOADS
- WALL BRACING AS SHOWN ON PLAN IS A MINIMUM ONLY.BUILDER TO PROVIDE ADDITIONAL BRACING TO SUIT THECONSTRUCTION OF WALL FRAMES IN ACCORDANCE WITHGOOD BUILDING PRACTICE.
- PLYWOOD BRACING IN ACCORDANCE WITH AS1684
- 65 x 19mm HW DIAGONAL TIMBER BRACING CHECKED INTOSTUDS AND FIXED IN ACCORDANCE WITH AS1684
TIMBER LINTELS FOR SINGLE (OR UPPER STORY) TO BE F17HARDWOOD AS FOLLOWS:0 - 1500 120 x 351500 - 2400 140 x 352400 - 2700 190 x 35
TIEDOWN AND FIXING CONNECTIONS TO COMPLY WITH AS1684
STEEL LINTELS FOR SINGLE (OR UPPER STOREY) TO BE ASFOLLOWS:0 - 2700 90 x 90 x 6 EA2700 - 3200 100 x 100 x 8 EA3200 - 4000 150 x 90 x 8 EA
*LINTELS REQUIRE 150mm BEARING EITHER SIDE OF OPENING
ALL LINTEL SIZES SHOWN ARE SUBJECT TO ENGINEERS DETAILS
CONCRETE- CONCRETE FOOTING AND SLABS TO BE IN ACCORDANCE WITH
AS2870
- CONCRETE TO BE MANUFACTURED TO COMPLY WITH AS3600AND:- HAVE A STRENGTH @ 28 DAYS OF NOT LESS THAN
25MpA (N25 GRADE)- HAVE A 20mm NOMINAL AGGREGATE SIZE- HAVE A NOMINAL 80mm SLUMP
- CONCRETE SLAB TO BE LAID OVER 0.2mm POLYTHENEMEMBRANE, 50mm WELL BEDDED SAND AND MINIMUMCOMPACTED FCR (20mm)
- SLAB THICKNESS AND REINFORCEMENT TO BE AS PERENGINEERS DESIGN
WINDOWS- WINDOWS TO BE ALUMINIUM FRAMED SLIDING UNLESS NOTED
OTHERWISE
- ALL WINDOWS TO BE FABRICATED AND INSTALLED INACCORDANCE WITH AS1288 AND AS2047 TO SPECIFIC WINDSPEED AS PER ENGINEERS REPORT
- ALL OPENING WINDOWS TO COMPLY WITH N.C.C. 3.6REQUIREMENTS
- AS PER N.C.C. 3.9.2.5 ALL BEDROOM WINDOWS WHERE THELOWEST OPENABLE PORTION OF THE WINDOW IS WITHIN 1.7mOF FFL AND THE FFL IS 2m OR MORE ABOVE NGL, REQUIRE APERMANANTLY FIXED DEVICE RESTRICTING ANY OPENINGSOF THE WINDOW OR SCREEN SO THAT A 125mm SPHERECANNOT PASS THROUGH; AND RESISTING OUTWARDSHORIZONTAL ACTION OF 250N AGAINST THE WINDOW. WHERETHE DEVICE OR SCREEN CAN BE REMOVED, UNLOCKED OROVER-RIDDEN, THE DEVICE OR SCREEN MUST HAVE A CHILDRESISTANT RELEASE MECHANISM INSTALLED AND BARRIERBELOW THE WINDOW THAT IS 865mm HIGH ABOVE FFL ANDRESTRICTS ANY OPENING WITHIN THE BARRIER SO THAT A125mm SPHERE CANNOT PASS THROUGH, AND HAS NOHORIZONTAL OR NEAR HORIZONTAL ELEMENTS BETWEEN150mm AND 760mm FROM FFL.
- GLAZING INSTALLED IN AREAS WITH HIGH POTENTIAL FORHUMAN IMPACT TO COMPLY WITH N.C.C. PART 3.6.4
DRAINAGE / WATER- DRAINAGE TO BE DESIGNED AND CONSTRUCTED IN
ACCORDANCE WITH AS3500 AND LOCAL AUTHORITY
- STORMWATER PIPES TO BE UPVC CLASS HD
- SEWER PIPES TO BE UPVC CLASS SH
- PROVIDE Ø20mm K2 POLYETHYLENE WATER RETICULATION
- TYPE B STOP VALVE TO BE LOCATED ADJACENT TO ENTRY
- BACKFILL ALL TRENCHES BENEATH VEHICLE PAVEMENT ANDSLABS ON GRADE TO FULL DEPTH WITH 20 FCR
- PROVIDE OVERFLOW RELIEF GULLY WITH TAP OVER. INVERTLEVEL TO BE 150 MIN. BELOW LOWEST SANITARY DRAINAGEPOINT.
- CUT AND BATTER ARE INDICATIVE. BATTER TO COMPLY WITHCURRENT N.C.C. TABLE 3.1.1.1
- AG DRAIN REQUIRED AROUND PERIMETER OF DWELLING FORALL CLASS M, H, E SITES. LOCATE AG DRAIN NOT CLOSERTHAN 1.5m FROM FOOTINGS IN ACCORDANCE WITH AS2870SECTION 5.6
- PROVIDE SURFACE DRAINAGE IN ACCORDANCE WITH AS2870SECTION 5.6.3
- PROVIDE FLEXIBLE JOINTS IN ALL DRAINAGE EMERGING FROMUNDERNEATH OR ATTACHED TO BUILDING IN ACCORDANCEWITH AS2870 SECTION 5.6.4 FOR ALL CLASS H AND E SITES.REFER TO GEOTECH FOR FURTHER INFORMATION
- DOWNPIPES AND GUTTERS DESIGNED IN ACCORDANCE WITHAS/NZS 3500.3
STAIRCASES / BALUSTRADES / HANDRAILSSTAIR TREADS 240mm MIN. - 355mm MAX.STAIR RISERS 115mm MIN. - 190mm MAX.
- HANDRAIL REQUIRED WHERE CHANGE OF LEVEL BETWEENFLOOR / LANDINGS > 1m AS PER CURRENT N.C.C. 3.9.2.4
- NO GAPS IN STAIRCASES OR BALUSTRADE TO BE GREATERTHAN 125mm
- BALUSTRADE REQUIRED WHERE LEVEL OF LANDING OR DECKIS GREATER THAN 1000mm ABOVE ADJACENT GROUND LEVEL
- BALUSTRADE TO BE MINIMUM 1000mm ABOVE FFL (INCLUDINGANY FLOOR COVERINGS)
- DOORS OPENING OUTWARDS EXTERNALLY MUST OPEN TO ALANDING (MIN. 750mm WIDE) WHERE THE DIFFERENCE INLEVELS IS GREATER THAN 570mm
- NON-SLIP TREADS TO ALL TREADS AND TO COMPLY WITHN.C.C. 3.9.1.4
- WHERE LANDINGS ARE NOT NOMINATED TO EXTERNALDOORS, OPERATING DOOR LEAFS ARE TO BE SCREWED FIXEDSHUT, OR PROVIDED WITH A FORMED FCR LANDINGNOMINALLY 180mm BELOW FLOOR LEVEL.
FIRE SAFETY- SMOKE ALARMS TO BE MAINS POWERED AND INSTALLED AS
PER AS3786. LOCATIONS AS PER N.C.C. 3.7.2.
- SMOKE ALARMS TO BE INTERCONNECTED WHERE THERE ISMORE THAN ONE ALARM
- INSTALLATION OF WOOD HEATERS TO COMPLY WITH AS2918.PROVIDE LOCAL AUTHORITIES WITH INSULATION ANDCOMPLIANCE CERTIFICATES
ROOFING- ROOF TO BE COLORBOND 'CUSTOM ORB' METALDECK UNLESS
NOTED OTHERWISE. PROVIDED AND INSTALLED INACCORDANCE WITH AS1562.1 (IF TILED REFER TO AS2050)
- PREFABRICATED ROOF TRUSSES TO BE SUPPLIED ANDINSTALLED TO MANUFACTURERS SPECIFICATIONS. TRUSSMANUFACTURER TO CONFIRM LINTEL SIZES.
WOOD HEATERS- ALL WOOD HEATERS ARE TO COMPLY WITH MANUFACTURERS
SPECIFICATION AND N.C.C. PART 3.7.3
CONDENSATION- WHERE RAKED CEILINGS EXIST, IT IS HIGHLY RECCOMENDED
THAT SUITABLE SPACING BETWEEN SARKING AND BULKINSULATION EXISTS. (NO CONTACT BETWEEN PRODUCTS).THE BUILDER IS TO ENSURE ADEQUATE SIZED TIMBER IS USEDTO ENSURE THIS SEPARATION IS PROVIDED.
- IN STANDARD ROOF SPACES, IT IS HIGHLY RECOMMENDED TOPROVIDE SEPARATION BETWEEN SARKING AND CEILINGINSULATION AROUND THE BUILDING PERIMETER, TO ENSUREAIRFLOW FROM EAVE VENTS IS MAINTAINED
- IT IS HIGHLY RECOMMENDED THAT ALL LIGHTWEIGHTCLADDING IS BATTENED OUT FROM STUDS (METAL / FC SHEET/ TIMBER)
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
THIS DWELLING IS BEING CONSTRUCTED IN A BAL N/A AREA(RESTRICTIONS FOR CONSTRUCTION METHODS/ MATERIALS MAY APPLY REFER NOTES)
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
GENERAL NOTESSCALES:SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:27 A
MTe
mplat
e Ver
sion:
21.02
0
20 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
VESSELS OR AREA WHERETHE FIXTURE IS INSTALLED
FLOORS ANDHORIZONTAL SURFACES WALLS PENETRATIONS
WATERPROOF ENTIRE ENCLOSEDSHOWER AREA INCLUDING HOB.
WATERPROOF ALLPENETRATIONS.
WATERPROOF ENTIRE ENCLOSEDSHOWER AREA, INCLUDINGWATERSTOP.
WATERPROOF ALLPENETRATIONS.
WATERPROOF ENTIRE ENCLOSEDSHOWER AREA INCLUDING THESTEPDOWN.
WATERPROOF ALLPENETRATIONS.
N/A WATERPROOF ALLPENETRATIONS.
UNENCLOSED SHOWERS WATERPROOF ENTIRE UNCLOSEDSHOWER AREA.
WATERPROOF ALLPENETRATIONS.
N/A N/A
WATERPROOF ENTIRE FLOOR. N/A N/A
ENCLOSED SHOWER WITH PRE-FORMEDSHOWER BASE
ENCLOSED SHOWER WITH STEPDOWN
WALL JUNCTIONS AND JOINTS
ENCLOSED SHOWER WITH HOB
ENCLOSED SHOWER WITHOUT HOB
WATER RESISTANT TO ENTIRE FLOOR.
WATER RESISTANT TO ENTIRE FLOOR.
WATERPROOF ENTIRE FLOOR.
INSERTED BATHS N/A FOR WALL UNDER BATH.
N/A
LAUNDRIES AND WCS N/A
WATERPROOF TO NOT LESS THAN 150mm ABOVE THESHOWER FLOOR SUBSTRATE OR NOT LESS THAN 25mmABOVE THE MAXIMUM RETAINED WATER LEVEL WHICHEVER IS THE GREATER WITH THE REMAINDER BEINGWATER RESISTANT TO A HEIGHT OF NOT LESS THAN1800mm ABOVE THE FINISHED FLOOR LEVEL.
WATERPROOF TO NOT LESS THAN 150mm ABOVE THESHOWER FLOOR SUBSTRATE OR NOT LESS THAN 25mmABOVE THE MAXIMUM RETAINED WATER LEVELWHICHEVER IS THE GREATER WITH THE REMAINDERBEING WATER RESISTANT TO A HEIGHT OF NOT LESSTHAN 1800mm ABOVE THE FINISHED FLOOR LEVEL.
WATER RESISTANT TO A HEIGHT OF NOT LESS THAN150mm ABOVE THE VESSEL AND EXPOSED SURFACESBELOW THE VESSEL LIP TO FLOOR LEVEL.
WATERPROOF EDGES OF THE VESSEL ANDJUNCTION OF BATH ENCLOSURE WITH FLOOR.WHERE THE LIP OF THE BATH IS SUPPORTEDBY A HORIZONTAL SURFACE, THIS MUST BEWATERPROOF FOR SHOWERS OVER BATH ANDWATER RESISTANT FOR ALL OTHER CASES.
WATERPROOF ALL TAP ANDSPOUT PENETRATIONSWHERE THEY OCCUR IN AHORIZONTAL SURFACE.
AREAS ADJACENT TO BATHS AND SPAS FORCONCRETE AND COMPRESSED FIBRECEMENT SHEET FLOORING.
AREAS ADJACENT TO BATHS AND SPAS (SEENOTE 1) FOR TIMBER FLOORS INCLUDINGPARTICLEBOARD, PLYWOOD AND OTHERTIMBER BASED FLOORING MATERIALS.
WATER RESISTANT TO A HEIGHT OF NOT LESS THAN150mm ABOVE THE VESSEL AND EXPOSED SURFACESBELOW THE VESSEL LIP TO FLOOR LEVEL.
WATERPROOF EDGES OF THE VESSEL ANDJUNCTION OF BATH ENCLOSURE WITH FLOOR.WHERE THE LIP OF THE BATH IS SUPPORTEDBY A HORIZONTAL SURFACE, THIS MUST BEWATERPROOF FOR SHOWERS OVER BATH ANDWATER RESISTANT FOR ALL OTHER CASES.
WATERPROOF ALL TAP ANDSPOUT PENETRATIONSWHERE THEY OCCUR IN AHORIZONTAL SURFACE.
WATERPROOF INTERNAL AND EXTERNALCORNERS AND HORIZONTAL JOINTS WITHIN AHEIGHT OF 1800mm ABOVE THE FLOOR LEVELWITH NOT LESS THAN 40mm WIDTH EITHERSIDE OF THE JUNCTION.
WATERPROOF INTERNAL AND EXTERNALCORNERS AND HORIZONTAL JOINTS WITHIN AHEIGHT OF 1800mm ABOVE THE FLOOR LEVELWITH NOT LESS THAN 40mm WIDTH EITHERSIDE OF THE JUNCTION.
WATERPROOF TO NOT LESS THAN 150mm ABOVE THESHOWER FLOOR SUBSTRATE WITH THE REMAINDERBEING WATER RESISTANT TO A HEIGHT OF NOT LESSTHAN 1800mm ABOVE THE FINISHED FLOOR LEVEL.
WATERPROOF INTERNAL AND EXTERNALCORNERS AND HORIZONTAL JOINTS WITHIN AHEIGHT OF 1800mm ABOVE THE FLOOR LEVELWITH NOT LESS THAN 40mm WIDTH EITHERSIDE OF THE JUNCTION.
WATERPROOF INTERNAL AND EXTERNALCORNERS AND HORIZONTAL JOINTS WITHIN AHEIGHT OF 1800mm ABOVE THE FLOOR LEVELWITH NOT LESS THAN 40mm WIDTH EITHERSIDE OF THE JUNCTION.
WATERPROOF INTERNAL AND EXTERNALCORNERS AND HORIZONTAL JOINTS WITHIN AHEIGHT OF 1800mm ABOVE THE FLOOR LEVELWITH NOT LESS THAN 40mm WIDTH EITHERSIDE OF THE JUNCTION.
WATER RESISTANT TO A HEIGHT OF NOT LESS THAN1800mm ABOVE FINISHED FLOOR LEVEL.
WATERPROOF TO NOT LESS THAN 150mm ABOVE THESHOWER FLOOR SUBSTRATE OR NOT LESS THAN 25mmABOVE THE MAXIMUM RETAINED WATER LEVEL WHICHEVER IS THE GREATER WITH THE REMAINDER BEINGWATER RESISTANT TO A HEIGHT OF NOT LESS THAN1800mm ABOVE THE FINISHED FLOOR LEVEL.
WATERPROOF ALL WALL/FLOOR JUNCTIONS.WHERE A FLASHING IS USED THE HORIZONTALLEG MUST BE NOT LESS THAN 40mm.
WATERPROOF ALL WALL/FLOOR JUNCTIONS.WHERE A FLASHING IS USED THE HORIZONTALLEG MUST BE NOT LESS THAN 40mm.
N/A FOR FLOOR UNDER BATH.WATERPROOF ENTIRE SHELF AREA,INCORPORATING WATERSTOP UNDERTHE BATH LIP AND PROJECT NOT LESSTHAN 5mm ABOVE THE TILE SURFACE.
N/A FOR WALL UNDER BATH. WATERPROOF TO NOTLESS THAN 150mm ABOVE THE LIP OF THE BATH.
WATERPROOF ALL TAP ANDSPOUT PENETRATIONSWHERE THEY OCCUR IN AHORIZONTAL SURFACE.
WALLS ADJOINING OTHER VESSELS (EG.SINKS, LAUNDRY TUBS AND BASINS)
WATER RESISTANT TO A HEIGHT OF NOT LESS THAN150mm ABOVE THE VESSEL IF THE VESSEL IS WITHIN75mm OF THE WALL.
WHERE THE VESSEL IS FIXED TO A WALL,WATERPROOF EDGES FOR EXTENT OF VESSEL.
WATERPROOF ALL TAP ANDSPOUT PENETRATIONSWHERE THEY OCCUR IN AHORIZONTAL SURFACE.
AREAS OUTSIDE THE SHOWER AREA FORTIMBER FLOORS INCLUDINGPARTICLEBOARD, PLYWOOD AND OTHERTIMBER BASED FLOORING MATERIALS
AREAS OUTSIDE THE SHOWER AREA FORCONCRETE AND COMPRESSED FIBRECEMENT SHEET FLOORING
WATER RESISTANT TO ENTIRE FLOOR. WATERPROOF ALL WALL/FLOOR JUNCTIONS TO NOTLESS THAN 25mm ABOVE THE FINISHED FLOOR LEVEL,SEALED TO FLOOR.
WATERPROOF ALL WALL/FLOOR JUNCTIONS.WHERE A FLASHING IS USED THE HORIZONTALLEG MUST BE NOT LESS THAN 40mm.
ENERGY EFFICIENCY - GENERALSTATED R VALUES ARE FOR ADDITIONAL INSULATION REQUIRED AND ARENOT RT VALUES (TOTAL SYSTEM VALUE)
INSULATION TO BE INSTALLED TO MANUFACTURERS SPECIFICATIONS ANDANY RELEVANT STANDARDS
BULK INSULATION IS NOT TO BE COMPRESSED AS THIS REDUCES THEEFFECTIVE R RATING
N.C.C 3.12.0 (A)PERFORMANCE REQUIREMENT P2.6.1 FOR THE THERMAL PERFORMANCE OFTHE BUILDING IS SATISFIED BY COMPLYING WITH:
3.12.0.1 - FOR REDUCING THE HEATING AND COOLING LOADSTO REDUCE HEATING AND COOLING LOADS MUST ACHIEVE AN ENERGYRATING USING HOUSING ENERGY RATING SOFTWARE OF NOT LESS THAN 6STARS.
3.12.1.1 - FOR BUILDING FABRIC THERMAL INSULATIONBUILDER TO ENSURE THAT ALL INSULATION COMPLIES WITH AS/NZS 4859.1AND BE INSTALLED TO N.C.C 3.12.1.1.
3.12.1.2(e) - FOR COMPENSATING FOR A LOSS OF CEILING INSULATIONREFER TO ATTACHED THERMAL PERFORMANCE CERTIFICATE(i) IF ALLOWANCE HAS BEEN MADE FOR CEILING PENERATIONS IN
NATHERS (FIRST RATE 5) CERTIFICATION PROCESS THEN NO FURTHERACTION REQUIRED.
(ii) IF NO ALLOWANCE HAS BEEN MADE FOR CEILING PENETRATIONS INNATHERS (FIRST RATE 5) CERTIFICATION PROCESS THEN CEILINGPENETRATION AREA MUST BE CALCULATED AND THE NECESSARYADJUSTMENT MADE TO THE SPECIFIED INSULATION AS PER TABLE3.12.1.1B OF N.C.C.
3.12.1.5(c) AND 3.12.1.5(d) - FOR FLOOR EDGE INSULATIONFOR CONCRETE SLAB ON GROUNG WITH IN SLAB HEATING OR COOLING.
3.12.3 - FOR BUILDING SEALING3.12.3.1 - CHIMNEYS AND FLUESTHE CHIMNEY OR FLUE OF AN OPEN SOLID FUEL BURNING APPLIANCE MUSTBE PROVIDED WITH A DAMPER OR FLAP THAT CAN BE CLOSED TO SEAL THECHIMNEY OR FLUE.
3.12.3.2 - ROOF LIGHTS(a) A ROOF LIGHT MUST BE SEALED, OR CAPABLE OF BEING SEALED WHEN
SERVING: (i) A CONDITIONED SPACE; OR (ii) A HABITABLE ROOM IN CLIMATE ZONES 4, 5, 6, 7 OR 8(b) A ROOF LIGHT REQUIRED BY (a) TO BE SEALED, OR CAPABLE OF BEING
SEALED MUST BE CONSTRUCTED WITH: (i) AN IMPERFORATE CEILING DIFFUSER OR THE LIKE INSTALLED AT A
CEILING OR INTERNAL LINING LEVEL; OR (ii) A WATERPROOF SEAL; OR (iii) A SHUTTER SYSTEM READILY OPERATED MANUALLY,
MECHANICALLY OR ELECTRONICALLY BY THE OCCUPANT.
3.12.0.1 - EXTERNAL WINDOWS AND DOORS(a) A SEAL TO RESTRIC AIR INFILTRATION MUST BE FITTED TO EACH OF AN
EXTERNAL DOOR, OPENABLE WINDOW AND OTHER SUCH OPENING: (I) WHEN SERVING A CONDITIONED SPACE; OR (II) IN CLIMATE ZONES 4, 5, 6, 7 OR 8, WHEN SERVING A HABITABLE
ROOM.(b) A WINDOW COMPLYING WITH THE MAXIMUM AIR INFILTRATION RATES
SPECIFIED IN AS2047 NEED NOT COMPLY WITH (a).(c) A SEAL REQUIRED BY (a) (i) FOR THE BOTTOM EDGE OF AN INTERNAL SWING DOOR, MUST BE A
DRAFT PROTECTION DEVICE; AND (ii) FOR THE OTHER EDGES OF AN EXTERNAL SWING DOOR OR THE
EDGES OF AN OPENABLE WINDOW OR OTHER SUCH OPENING, MAYBE A FOAM OR RUBBER COMPRESSIBLE STRIP, FIBROUS SEAL ORTHE LIKE.
3.12.3.4 - EXHAUST FANSAN EXHAUST FAN MUST BE FITTED WITH A SEALING DEVICE SUCH AS A SELFCLOSE DAMPER, FILTER OR THE LIKE WHEN SERVING:(a) A CONDITIONED SPACE; OR(b) A HABITABLE ROOM IN THE CLIMATE ZONES 4, 5, 6, 7 OR 8.
3.12.3.5 - CONSTRUCTION OF ROOF, WALLS AND FLOORS(a) ROOFS, EXTERNAL WALLS, EXTERNAL FLOORS AND AN OPENING SUCH
AS A WINDOW FRAME, DOOR FRAME, ROOF LIGHT FRAME OR THE LIKEMUST BE CONSTRUCTED TO MINIMISE AIR LEAKAGE IN ACCORDANCEWITH (b) WHEN FORMING PART OF THE EXTERNAL FABRIC OF:
(i) A CONDITIONED SPACE; OR (ii) A HABITABLE ROOM IN CLIMATE ZONE 4, 5, 6, 7 OR 8.(b) CONSTRUCTION REQUIRED BY (a) MUST BE: (i) ENCLOSED BY AN INTERNAL LINING SYSTEM THAT ARE CLOSE
FITTING AT CEILING, WALL AND FLOOR JUNCTIONS; OR (ii) SEALED BY CAULKING, SKIRTING, ARCHITRAVES, CORNICES OR THE
LIKE.
3.12.3.6 - EVAPORATIVE COOLERSAN EVAPORATIVE COOLER MUST BE FITTED WITH A SELF CLOSING DAMPEROR THE LIKE WHEN SERVING:(a) A HEATED SPACE; OR(b) A HABITABLE ROOM IN CLIMATE ZONES 4, 5, 6, 7 OR 8.
3.12.5.5 - ARTIFICIAL LIGHTING(a) LAMP POWER DENSITY OR ILLUMINATION POWER DENSITY OF AN
ARTIFICIAL LIGHT, EXCLUDING HEATING THAT EMITS LIGHT, MUST NOTEXCEED THE ALLOWANCE OF:
(i) 5W/m² IN A CLASS 1 BUILDING (ii) 4W/m² ON A VERANDAH, BALCONY OR THE LIKE ATTACHED TO A
CLASS 1 BUILDING (NOT EXCLUDING EAVE PERIMETER LIGHTS); (iii) 3W/m² IN A CLASS 10A BUILDING ASSOCIATED WITH A CLASS 1
BUILDING.(b) THE ILLUMINATION POWER DENSITY ALLOWANCE IN (a) MAY BE
INCREASED BY DIVIDING IT BY THE ILLUMINATION POWER DENSITYADJUSTMENT FACTOR FOR A CONTROL DEVICE AS PER N.C.C TABLE3.12.5.3.
WET AREA NOTES
THE ABOVE INFORMATION IS FOR GENERAL GUIDANCE AND IS INDICATIVE ONLY. WATERPROOFING INSTALLERS TO COMPLY WITH ALL CURRENT CODES OF LEGISLATION WHICH TAKE PRECEDENCE OVER THIS SPECIFICATION.
WET AREA WAERPROOFING BY LICENSED AND ACCREDITED INSTALLER. CERTIFICATION TO BE PROVIDED TO BUILDING SURVEYOR. CONTRACTOR OR BUILDER TO DETERMINE THE APPROPRIATE WATERPROOFING INACCORDANCE WITH AS3740 PART 3.8.1 AND TABLE 3.8.1.1 OF N.C.C AND TO NOTIFY THE BUILDING SURVEYOR FOR INSPECTION ARRANGEMENTS DURING INSTALLATION.
THIS PLAN ACCEPTED BY:
PLEASE NOTE: NO VARIATIONS WILL BEACCEPTED ON THIS PLAN AFTER SIGNING
SIGNATURE:
DATE:
THIS DWELLING IS BEING CONSTRUCTED IN A BAL N/A AREA(RESTRICTIONS FOR CONSTRUCTION METHODS/ MATERIALS MAY APPLY REFER NOTES)
© 2021 WILSON HOMES PTY LTD (ABN 96 126 636 897). THIS DRAWING IS AN ORIGINAL ARTISTIC WORK WITHIN THE MEANING OF THE COPYRIGHT ACT 1968 (CTH). WILSON HOMES PTY LTD IS THE OWNER OF COPYRIGHT IN THIS DRAWING. YOU HEREBY AGREE AND UNDERTAKE THAT YOUWILL NOT IN ANY WAY REPRODUCE, COPY, MODIFY, USE OR TAKE ADVANTAGE OF THE DRAWING TO BUILD A HOUSE BASED ON THIS PLAN (WHETHER IN WHOLE OR IN PART) WITHOUT THE PRIOR WRITTEN CONSENT OF WILSON HOMES PTY LTD.
REVISION DRAWN
7 BA PLAN SET - DRAINAGE PLAN UPDATE RMF 2021.07.28
6 BA PLAN SET - COUNCIL RFI CPO 2021.07.26
5 BA PLAN - SWMP UPDATE MSP 2021.07.15
4 BA - RESITE & SW TRENCH TO GES DESIGN RLW 2021.07.12
3 BA PLAN SET - INITIAL ISSUE- COLOURS, PCV, RFI RLW 2021.04.19
CLIENT:
MR FRANCISCO NAVIDADADDRESS:
10 PARDALOTE CLOSE, OPOSSUM BAY TAS 7023LOT / SECTION / CT:
15 / - / 177924COUNCIL:
CLARENCE COUNCIL
HOUSE DESIGN:
AMALFI ONE (MODIFIED)HOUSE CODE:
H-WDNAMF10SAFACADE DESIGN:
RYDEFACADE CODE:
F-WDNAMF10RYDEASHEET TITLE:
WET AREA & ENERGY EFFICIENCY NOTESSCALES:SHEET No.: 712845
DO NOT SCALE DRAWINGS, USEFIGURED DIMENSIONS ONLY. CHECK
AND VERIFY DIMENSIONS ANDLEVELS PRIOR TO THE
COMMENCEMENT OF ANY WORK. ALLDISCREPANCIES TO BE REPORTED
TO THE DRAFTING OFFICE.
File L
ocati
on: P
:\8. D
raftin
g\Job
File
s\712
800\7
1284
5 - N
avida
d - A
21\P
lans\7
1284
5 - N
avida
d - B
A - 2
021.0
7.28.p
lnLa
st Pu
blish
ed: W
edne
sday
, 28 J
uly 20
21 10
:27 A
MTe
mplat
e Ver
sion:
21.02
0
21 / 21Version: 1, Version Date: 30/07/2021Document Set ID: 4625343
Geo-Environmental Solutions. 29 Kirksway Place Battery Point. Ph 6223 1839
3/5/2021
To: Wilson Homes
RE: Stormwater retention and management – 10 Pardalote Close, Opossum Bay (712845)
In response to your inquiry regarding stormwater retention, I can advise the following:
Soil conditions
The soils on site are developing on Quaternary sediments with an estimated permeability of
5m/day.
Stormwater calculations
Stormwater runoff from impervious surfaces on site (new roof area) is calculated according to the
rational method taken from Australian Rainfall and Runoff (ARR).
Where the flowrate Q = 0.000278CIA
C = Runoff coefficient (taken as 0.90 for roof and 0.75 for gravel)
I = Intensity of rainfall
A = Catchment area
All 1:20yr scenarios (5 minutes to 72 hours) have been calculated in the attached spread sheet.
The Intensity Frequency Duration (IFD) data generated for the site is shown in the attached charts
and table.
For proposed total new roof area of approximately 160m2
The required stormwater trench area from the stormwater worksheet attached is 7m2. This can be
installed as one 5m long by 1.5m wide by 0.6m deep absorption trench to accommodate the
calculated stormwater overflow from the roof area.
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions. 29 Kirksway Place Battery Point. Ph 6223 1839
Summary
One absorption trench is proposed to retain stormwater overflow onsite. Overflow from the new
roof area will require one absorption trench 5m x 1.5m x 0.6m.
The resultant stormwater retention area/volume should therefore be sufficient to handle all ARI
1:20 events and complies with the development standards outlined in E7.7.1 P1.
Please contact me if you have any further questions.
Dr John Paul Cumming PhD CPSS
Director
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions. 29 Kirksway Place Battery Point. Ph 6223 1839
Stormwater calculations – dwelling roof area – 160m2
CATCHMENT AREA (m2) 160 Ksat (m/d) 5 Absorption length (m) 5 Absorption area (m2) 7.5
Catchement Type Roof AEP 5% Absorption width (m) 1.5 Absorption perimeter (m) 13
Moderation Factor 1 Depth (m) 0.6 Absorption depth (m) 0.6
5% AEP Infiltration (L/m2) Storm Volume (L) Trench infitration in L (volume -area shown)
Storm Duration Intensity mm/hr Flow rate (L/s) (L/m2) 160 m2 catchment500L - 2.1 m2 730L - 3.125 m2 1000L - 4.2 m2 1500L - 6.25 m2 2000L - 8.35 m2 2500L - 10.45 m2 3000L - 12.5 m2
1 min 138 5.52 3.47 331.46 7.23 10.49 14.47 21.70 28.94 36.17 43.40
2 min 108 4.32 6.94 518.81 14.47 20.98 28.94 43.40 57.87 72.34 86.81
3 min 98.1 3.93 10.42 706.89 21.70 31.47 43.40 65.10 86.81 108.51 130.21
4 min 90.7 3.63 13.89 871.42 28.94 41.96 57.87 86.81 115.74 144.68 173.61
5 min 84.7 3.39 17.36 1017.21 36.17 52.45 72.34 108.51 144.68 180.84 217.01
10 min 64 2.56 34.72 1537.23 72.34 104.89 144.68 217.01 289.35 361.69 434.03
15 min 51.9 2.08 52.08 1869.89 108.51 157.34 217.01 325.52 434.03 542.53 651.04
20 min 44.1 1.77 69.44 2118.49 144.68 209.78 289.35 434.03 578.70 723.38 868.06
25 min 38.7 1.55 86.81 2323.86 180.84 262.23 361.69 542.53 723.38 904.22 1085.07
30 min 34.6 1.39 104.17 2493.19 217.01 314.67 434.03 651.04 868.06 1085.07 1302.08
45 min 27 1.08 156.25 2918.33 325.52 472.01 651.04 976.56 1302.08 1627.60 1953.13
1 hour 22.6 0.90 208.33 3257.00 434.03 629.34 868.06 1302.08 1736.11 2170.14 2604.17
1.5 hour 17.8 0.71 312.50 3847.88 651.04 944.01 1302.08 1953.13 2604.17 3255.21 3906.25
2 hour 15.2 0.61 416.67 4381.10 868.06 1258.68 1736.11 2604.17 3472.22 4340.28 5208.33
3 hour 12.3 0.49 625.00 5317.85 1302.08 1888.02 2604.17 3906.25 5208.33 6510.42 7812.50
4.5 hour 10 0.40 937.50 6485.18 1953.13 2832.03 3906.25 5859.38 7812.50 9765.63 11718.75
6 hour 8.78 0.35 1250.00 7591.99 2604.17 3776.04 5208.33 7812.50 10416.67 13020.83 15625.00
9 hour 7.26 0.29 1875.00 9416.49 3906.25 5664.06 7812.50 11718.75 15625.00 19531.25 23437.50
12 hour 6.33 0.25 2500.00 10946.99 5208.33 7552.08 10416.67 15625.00 20833.33 26041.67 31250.00
18 hour 5.13 0.21 3750.00 13307.60 7812.50 11328.13 15625.00 23437.50 31250.00 39062.50 46875.00
24 hour 4.36 0.17 5000.00 15080.21 10416.67 15104.17 20833.33 31250.00 41666.67 52083.33 62500.00
30 hour 3.79 0.15 6250.00 16385.90 13020.83 18880.21 26041.67 39062.50 52083.33 65104.17 78125.00
36 hour 3.35 0.13 7500.00 17380.29 15625.00 22656.25 31250.00 46875.00 62500.00 78125.00 93750.00
48 hour 2.71 0.11 10000.00 18746.51 20833.33 30208.33 41666.67 62500.00 83333.33 104166.67 125000.00
72 hour 1.93 0.08 15000.00 20026.25 31250.00 45312.50 62500.00 93750.00 125000.00 156250.00 187500.00
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions. 29 Kirksway Place Battery Point. Ph 6223 1839
Catchment Area = 160 m2 Infiltration Area = 7.5 m2
Runoff Coefficient = 0.9 Perimeter = 13 m
Soil Kh = 208.333 mm/hr Emptying time = 1.01 hr
Moderating factor = 1
Width Infiltration = 1.5 m
Length = 5 m
Depth = 0.6 m Volume 4.5 m3
Porosity = 0.35 Volume Storage Provided 1.575 m3
5% AEP
Storm Duration Intensity Inflow Volume Outflow Volume Required Emptying time
(mm/hr) (m3) (m3) (m3) (hr)
1 min 138 0.33 0.04 0.29 0.19
2 min 108 0.52 0.08 0.44 0.28
3 min 98.1 0.71 0.12 0.59 0.38
4 min 90.7 0.87 0.16 0.71 0.46
5 min 84.7 1.02 0.20 0.82 0.52
10 min 64 1.54 0.40 1.14 0.73
15 min 51.9 1.87 0.59 1.27 0.82
20 min 44.1 2.12 0.79 1.33 0.85
25 min 38.7 2.32 0.99 1.33 0.85
30 min 34.6 2.49 1.19 1.30 0.83
45 min 27 2.92 1.78 1.13 0.73
1 hour 22.6 3.25 2.38 0.88 0.56
1.5 hour 17.8 3.84 3.56 0.28 0.18
2 hour 15.2 4.38 4.75 - -
3 hour 12.3 5.31 7.13 - -
4.5 hour 10 6.48 10.69 - -
6 hour 8.78 7.59 14.25 - -
9 hour 7.26 9.41 21.38 - -
12 hour 6.33 10.94 28.50 - -
18 hour 5.13 13.30 42.75 - -
24 hour 4.36 15.07 57.00 - -
30 hour 3.79 16.37 71.25 - -
36 hour 3.35 17.37 85.50 - -
48 hour 2.71 18.73 114.00 - -
72 hour 1.93 20.01 171.00 - -
Full volume 1.58 0.85
Notes:
Inflow volume calculated using Equation 10.1 (WSUD Guidelines: Chapter 10)
Outflow volume calculated using Equation 10.2 (WSUD Guidelines: Chapter 10)
Required storage and emptying time is left blank when outflow volume exceeds inflow volume
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions. 29 Kirksway Place Battery Point. Ph 6223 1839
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions. 29 Kirksway Place Battery Point. Ph 6223 1839
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Director of Building Control - date approved: 2 August 2017 Building Act 2016 - Approved Form No 35
CERTIFICATE OF THE RESPONSIBLE DESIGNER Section 94Section 106Section 129Section 155
To: Wilson Homes Owner name
250 Murray Street Address
Hobart 7000 Suburb/postcode
Designer details:Name:
John-Paul CummingCategory: Bld. Srvcs. Dsgnr. -
Hydraulic
Business name: Geo-Environmental Solutions Phone No: 03 6223 1839
Business address: 29 Kirksway Place
Battery Point 7004 Fax No: N/A
Licence No: CC774A Email address: [email protected]
Details of the proposed work:
Owner/Applicant Wilson Homes Designer’s projectreference No. J2746
Address: Lot 15, 10 Pardalote Close Lot No: 177924/15Opossum Bay 7023
Type of work: Building work Plumbing work X (X all applicable)
Description of work:On-site wastewater management system - design (new building / alteration /
addition / repair / removal / re-erection water / sewerage / stormwater / on-site wastewater management system / backflow prevention / other)
Description of the Design Work (Scope, limitations or exclusions): (X all applicable certificates)
Certificate Type: Certificate Responsible Practitioner Building design Architect or Building Designer
Structural design Engineer or Civil Designer
Fire Safety design Fire Engineer
Civil design Civil Engineer or Civil Designer
Hydraulic design Building Services Designer
Fire service design Building Services Designer
Electrical design Building Services Designer
Mechanical design Building Service Designer
Plumbing design Plumber-Certifier; Architect, Building Designer or Engineer
Other (specify)
Deemed-to-Satisfy: Performance Solution: (X the appropriate box)
Other details:
Dual-purpose septic tank and onsite absorption. Onsite stormwater retention
Design documents provided:
Form 35
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Director of Building Control - date approved: 2 August 2017 Building Act 2016 - Approved Form No 35
The following documents are provided with this Certificate –Document description:Drawing numbers: Prepared by: Geo-Environmental Solutions Date: May-21
Schedules: Prepared by: Date:
Specifications: Prepared by: Geo-Environmental Solutions Date: May-21
Computations: Prepared by: Date:
Performance solution proposals:Onsite stormwater retention
Prepared by: Geo-Environmental Solutions Date: May-21
Test reports: Prepared by: Geo-Environmental Solutions Date: May-21
Standards, codes or guidelines relied on in design process:AS1547-2012 On-site domestic wastewater management.
AS3500 (Parts 0-5)-2013 Plumbing and drainage set.
Any other relevant documentation:
Geo-Environmental Assessment - Lot 15, 10 Pardalote Close, Opossum Bay 712845 - May-21Stormwater Assessment - Lot 15, 10 Pardalote Close, Opossum Bay 712845 - May-21
Form 55 for onsite stormwater retention
Attribution as designer:I John-Paul Cumming, am responsible for the design of that part of the work as described in this certificate;
The documentation relating to the design includes sufficient information for the assessment of the work in accordance with the Building Act 2016 and sufficient detail for the builder or plumber to carry out the work in accordance with the documents and the Act;
This certificate confirms compliance and is evidence of suitability of this design with the requirements of the National Construction Code.
Name: (print) Signed Date
Designer: John-Paul Cumming 03/05/2021
Licence No: CC774A
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Director of Building Control - date approved: 2 August 2017 Building Act 2016 - Approved Form No 35
Assessment of Certifiable Works: (TasWater)
Note: single residential dwellings and outbuildings on a lot with an existing sewer connection are not considered to increase demand and are not certifiable.If you cannot check ALL of these boxes, LEAVE THIS SECTION BLANK. TasWater must then be contacted to determine if the proposed works are Certifiable Works.
I confirm that the proposed works are not Certifiable Works, in accordance with the Guidelines for TasWater CCW Assessments, by virtue that all of the following are satisfied:
x The works will not increase the demand for water supplied by TasWater
x The works will not increase or decrease the amount of sewage or toxins that is to be removed by, or discharged into, TasWater’s sewerage infrastructure
x The works will not require a new connection, or a modification to an existing connection, to be made to TasWater’s infrastructure
x The works will not damage or interfere with TasWater’s works
x The works will not adversely affect TasWater’s operations
x The work are not within 2m of TasWater’s infrastructure and are outside any TasWater easement
x I have checked the LISTMap to confirm the location of TasWater infrastructure
x If the property is connected to TasWater’s water system, a water meter is in place, or has been applied for to TasWater.
Certification:
I .......... John-Paul Cumming........................ being responsible for the proposed work, am satisfied that the works described above are not Certifiable Works, as defined within the Water and Sewerage Industry Act 2008, that I have answered the above questions with all due diligence and have read and understood the Guidelines for TasWater CCW Assessments.Note: the Guidelines for TasWater Certification of Certifiable Works Assessments are available at: www.taswater.com.au
Name: (print) Signed Date
Designer: John-Paul Cumming 03/05/2021
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
ABSORPTION TRENCH1 x 15m x 2m x 0.6m
DUAL-PURPOSE SEPTIC TANK(MIN 3000L)
100% RESERVE AREA
Wastewater system:
Dual-purpose septic tank (min 3000L)
Absorption Trench1 x 15m x 2m x 0.6m
Min 3m from upslope buildingsMin 6m from downslope buildingsMin 1.5m from upslope or level boundariesMin 2m from downslope boundary Min 100m from downslope surface water
Refer to GES report
29 Kirksway Place Battery PointT| 62231839 E| [email protected]
4/12/2020
2m min
1.5mmin
STORMWATER ABSORPTION1 x 5m x 1.5m x 0.6m
Stormwater system:
All roof and tank overflow to be retainedonsite
Absorption Trench1 x 5m x 1.5m x 0.6m
Min 1.5m from buildings or boundaries
Refer to GES report
29 Kirksway Place Battery PointT| 62231839 E| [email protected]
3/5/2021
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions P/L 29 Kirksway Place Battery Point 7004. Ph 6223 1839 Fax 6223 4539
GEO-ENVIRONMENTAL ASSESSMENT
Lot 15, 10 Pardalote Close
Opossum Bay
November 2020
Wilson Homes Job No: 712845
Disclaimer: The author does not warrant the information contained in this document is free from errors or
omissions. The author shall not in any way be liable for any loss, damage or injury suffered by the User
consequent upon, or incidental to, the existence of errors in the information.
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions Pty Ltd – Site Assessment Lot 15, 10 Pardalote Close
2
Introduction
Client: Wilson Homes
Date of inspection: 30/11/20
Location: Lot 15, 10 Pardalote Close, Opossum Bay
Land description: Approx. 1758m2 residential lot
Building type: Proposed dwelling
Investigation: 70mm hand auger
Inspected by: J Cumming
Background Information
Map: Mineral Resources Tasmania: South Arm Sheet 1:25 000
Rock type: Quaternary sediments
Soil depth: 2.0m+
Planning overlays: None identified
Local meteorology: Annual rainfall approx. 550 mm
Local services: Tank water with onsite wastewater
Site Conditions
Slope and aspect: Approx. 1% slope to the east
Site drainage: Well drained
Vegetation: Weed sp
Weather conditions: Cloudy, approx. 5mm rainfall received in preceding 7 days.
Ground surface: Dry surface conditions
Investigation
A number of excavations were completed to identify the distribution of, and variation in soil
materials on the site. Representative excavations were taken at the approximate locations
indicated on the site plan and were chosen for testing and classification according to
AS2870-2011 and AS1547-2012 (see profile summary).
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions Pty Ltd – Site Assessment Lot 15, 10 Pardalote Close
3
Profile Summary
Holes 1 & 2
Depth (m)
Horizon Description
0.00 – 0.20 A1 Greyish Brown SAND (SW), single grain, dry loose
consistency, gradual boundary to
0.20 – 0.40 A2 Pale Brown SAND (SW), single grain, dry loose
consistency, gradual boundary to
0.40 – 2.0+ AC
Light Yellowish Brown SAND (SW), trace of clay, single
grain, slightly moist medium dense consistency, lower
boundary undefined.
Soil Profile Notes
The soils on site features deep sand horizons formed from Quaternary sediments. The sandy
soils are non-reactive.
Site Classification
According to AS2870-2011 for construction the natural soil is classified as Class A, which is
a non-reactive site. Due to the poor bearing capacity in the upper profile, it is recommended
footings are placed below 0.9m depth. Design and construction must adhere to this
classification.
Wind Classification
The AS 4055-2012 Wind load for housing classification of the site is:
Region: A
Terrain category: TC2
Shielding Classification: NS
Topographic Classification: T2
Wind Classification: N3
Design Wind Gust Speed ( V h,u ) 50 m/sec
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions Pty Ltd – Site Assessment Lot 15, 10 Pardalote Close
4
Wastewater Classification & Recommendations
According to AS1547-2012 (on-site waste-water management) the natural soil is classified
as SAND (category 1) with a Design Loading Rate (DLR) of 25L/m2/day. The assigned
DLR is based upon professional assessment of the structure, composition, and drainage
characteristics of the soil on the site by an experienced soil scientist. The assigned DLR is
within the allowable range for the soil category, the effluent type, and the system design as
prescribed in AS/NZS1547.
The proposed four-bedroom equivalent dwelling has a calculated maximum wastewater
loading of 720L/day. This is based on tank water supply and a maximum occupancy of 6
people (120L/day/person).
Using the DLR of 25L/m2/day, an absorption area of 30m2 will be required. This can be
accommodated by one 15m x 2m x 0.6m absorption trench connected to a dual-purpose
septic tank (min 3000L) with outlet filter. Due to the highly permeable soils, a cut-off
diversion drain will not be required. The wastewater area must be excluded from traffic or
any future building works and a 100% reserve area must be set aside for future wastewater
requirements. For further detail please refer to the attached plan and Trench summary
reports.
The following setback distances are required to comply with the Building Act 2016:
Upslope or level buildings: 3m
Downslope buildings: 6m
Upslope or level boundaries: 1.5m
Downslope boundaries: 2m
Downslope surface water: 100m
Compliance with Building Act 2016 Guidelines for On-site Wastewater Management
Systems is outlined in the attached table.
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions Pty Ltd – Site Assessment Lot 15, 10 Pardalote Close
5
Construction Recommendations
According to AS2870-2011 for construction the natural soil is classified as Class A which is
a non-reactive site. Care must be taken to ensure founding in subsoils with adequate bearing
capacity (below approximately 0.9m depth). All site Earthworks must comply with AS3798-
2012. Consideration should be given to drainage and sediment control on site during and
after construction to minimise loss of the sandy materials on site.
During construction GES will need to be notified of any variation to the soil conditions or
wastewater loading as outlined in this report.
Dr John Paul Cumming B.Agr.Sc (hons) PhD CPSS GAICD
Environmental and Engineering Soil Scientist
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions Pty Ltd – Site Assessment Lot 15, 10 Pardalote Close
6
Dynamic Cone Penetration (DCP) Conversion to Californian Bearing Ratio
(ref: Australian Standard AS 1289.6.3.2 - 1997)
Date 30/11/2020
Location 10 Pardalote Close, Opossum Bay
Bedrock Depth (mm) not encountered
Water Table Location not encountered
DCP Commencement Depth 0
DCP Measure 100
Slope and Aspect 1% E
Depth (mm) DCP DCP DCP Resistance Bearing Capacity CBR
(Blows/100mm) (mm/Blow) (mPa) (kPa)
0-100 1 100.0 0.4 42 2
100-200 2 50.0 0.7 84 4
200-300 1 100.0 0.4 42 2
300-400 1 100.0 0.4 42 2
400-500 2 50.0 0.7 84 4
500-600 1 100.0 0.4 42 2
600-700 1 100.0 0.4 42 2
700-800 1 100.0 0.4 42 2
800-900 2 50.0 0.7 84 4
900-1000 2 50.0 0.7 84 4
1000-1100 2 50.0 0.7 84 4
1100-1200 3 33.3 1.1 126 6
1200-1300 5 20.0 1.8 210 10
1300-1400 6 16.7 2.1 252 13
1400-1500 7 14.3 2.5 294 15
1500-1600 7 14.3 2.5 294 15
1600-1700 7 14.3 2.5 294 15
1700-1800 8 12.5 2.9 336 17
1800-1900 8 12.5 2.9 336 17
1900-2000 9 11.1 3.2 378 20
2000-2100 11 9.1 3.9 462 25
2100-2200 10 10.0 3.6 420 22
2200-2300 11 9.1 3.9 462 25
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions Pty Ltd – Site Assessment Lot 15, 10 Pardalote Close
7
GES P/L
Land suitability and system sizing for on-site wastewater management
Assessment ReportSite assessment for on-site waste water disposal
Assessment for Wilson Homes Assess. Date
Ref. No.
Assessed site(s) 10 Pardalote Close Opossum Bay Site(s) inspected
Local authority Clarence Assessed by
B.Agr.Sc(hons) PhD
Wastewater CharacteristicsWastewater volume (L/day) used for this assessment = (using the 'No. of bedrooms in a dwelling' method)
Septic tank wastewater volume (L/day) = Sullage volume (L/day) =
Total nitrogen (kg/year) generated by wastewater = Total phosphorus (kg/year) generated by wastewater =
Climatic assumptions for site (Evapotranspiration calculated using the crop factor method)
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Mean rainfall (mm) 44 39 44 45 40 43 46 46 43 52 48 54Adopted rainfall (R, mm) 44 39 44 45 40 43 46 46 43 52 48 54
Retained rain (Rr, mm) 40 35 40 41 36 39 41 41 39 47 43 49Max. daily temp. (deg. C)
Evapotrans (ET, mm) 130 110 91 63 42 29 32 42 63 84 105 126Evapotr. less rain (mm) 91 75 51 23 6 -9 -10 1 24 37 62 77
Annual evapotranspiration less retained rain (mm) = 427
Soil characterisitics
Texture = Category = 1 Thick. (m) = 2
Adopted permeability (m/day) = Adopted LTAR (L/sq m/day) = 25 Min depth (m) to water = 5
Proposed disposal and treatment methods
Proportion of wastewater to be retained on site: All wastewater will be disposed of on the siteThe preferred method of on-site primary treatment: In dual purpose septic tank(s)
The preferred method of on-site secondary treatment: In-groundThe preferred type of in-ground secondary treatment: Trench(es)
The preferred type of above-ground secondary treatment: NoneSite modifications or specific designs: Not needed
Suggested dimensions for on-site secondary treatment system
Total length (m) = Width (m) = 2Depth (m) = 0.6
Total disposal area (sq m) required = comprising a Primary Area (sq m) of:
and a Secondary (backup) Area (sq m) of: Sufficient area is available on site
30-Nov-20
John Paul Cumming
1.8
3
Sand
240
2929
14
480
720
2.2
4-Dec-20
This report summarises wastewater volumes, climatic inputs for the site, soil characteristics and sustem sizing and design issues. SiteCapability and Environmental sensitivity issues are reported separately, where 'Alert' columns flag factors w ith high (A) or very high (AA)
limitations w hich probably require special consideration for system design(s). Blank spaces on this page indicate data have not been enteredinto TRENCH.
To enter comments, click on the line below 'Comments'. (This yellow-shaded box and the buttons on this page will not be printed.)
Comments
The calculated DLR for the Category 1 soil present is 25L/sq m/day with a required absorption area of 30sq m for the
proposed development. Therefore the system will have the capacity to cope with predicted climatic and loading events.
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions Pty Ltd – Site Assessment Lot 15, 10 Pardalote Close
8
GES P/L
Land suitability and system sizing for on-site wastewater management
Site Capability ReportSite assessment for on-site waste water disposal
Assessment for Wilson Homes Assess. Date
Ref. No.
Assessed site(s) 10 Pardalote Close Opossum Bay Site(s) inspected
Local authority Clarence Assessed by
B.Agr.Sc(hons) PhD
Expected design area sq m V. high Moderate No change
Density of disposal systems /sq km Mod. Moderate
Slope angle degrees High Very low
Slope form Straight simple High Low
Surface drainage Good High Very low
Flood potential Site floods <1:100 yrs High Very low
Heavy rain events Infrequent High Moderate
Aspect (Southern hemi.) Faces E or W V. high Moderate
Frequency of strong winds Common High Low
Wastewater volume L/day High Moderate No change
SAR of septic tank effluent High Low
SAR of sullage High Moderate
Soil thickness m V. high Very low
Depth to bedrock m V. high Very low
Surface rock outcrop % V. high Very low
Cobbles in soil % V. high Very low
Soil pH High Low
Soil bulk density gm/cub. cm High Very low
Soil dispersion Emerson No. V. high Very low
Adopted permeability m/day Mod. Very high Moderate
Long Term Accept. Rate L/day/sq m High Moderate No change
4-Dec-20
30-Nov-20
0
1.4
1.7
2.0
8
5.5
25
3 Other factors lessen impact
720
2.6
0
3.0
20
Limitation
1,000
1
John Paul Cumming
To enter comments, click on the line below 'Comments' . (This yellow-shaded box and the buttons on this page will not be printed.)
This report summarises data relating to the physical capability of the assessed site(s) to accept wastewater. Environmental sensitivity andsystem design issues are reported separately. The 'Alert' column flags factors w ith high (A) or very high (AA) site limitations w hich probably
require special consideration in site acceptability or for systemdesign(s). Blank spaces indicate data have not been entered into TRENCH.
Comments
The site has the capability to accept onsite wastewater.
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Geo-Environmental Solutions Pty Ltd – Site Assessment Lot 15, 10 Pardalote Close
9
GES P/L
Land suitability and system sizing for on-site wastewater management
Environmental Sensitivity ReportSite assessment for on-site waste water disposal
Assessment for Wilson Homes Assess. Date
Ref. No.
Assessed site(s) 10 Pardalote Close Opossum Bay Site(s) inspected
Local authority Clarence Assessed by
B.Agr.Sc(hons) PhD
AA Cation exchange capacity mmol/100g High Very high
A Phos. adsorp. capacity kg/cub m High High
Annual rainfall excess mm High Very low
Min. depth to water table m High Very low
Annual nutrient load kg High Very low
A G'water environ. value Recreational V. high High
Min. separation dist. required m High Very low
Risk to adjacent bores Very low V. high Very low
A Surf. water env. value Recreational V. high High
Dist. to nearest surface water m V. high Moderate
Dist. to nearest other feature m V. high Moderate No change
Risk of slope instability Very low V. high Very low
Distance to landslip m V. high Low
John Paul Cumming
5
3.9
2
Limitation
20
0.2
-427
30-Nov-20
200
250
50
4-Dec-20
To enter comments, click on the line below 'Comments'. (This yellow-shaded box and the buttons on this page will not be printed.)
This report summarises data relating to the environmental sensitivity of the assessed site(s) in relation to applied w astewater. Physicalcapability and system design issues are reported separately. The 'Alert' column flags factors with high (A) or very high (AA) limitations w hich
probably require special consideration in site acceptability or for system design(s). Blank spaces indicate data have not been entered intoTRENCH.
Comments
The soil on site has a sandy texture and a low CEC, therefore the soil system has a low capacity to cope with the applied
nutrient load from the system. The planting of deep rooted grasses is recommended to encourage nutrient uptake. Thewastewater system complies with the required setbacks to downslope surface water.
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Demonstration of wastewater system compliance to Building Act 2016 Guidelines for On-site Wastewater Disposal
Acceptable Solutions Performance Criteria Compliance
A1
Horizontal separation distance from a building to a
land application area must comply with one of the
following:
a) be no less than 6m; or
b) be no less than:
(i) 3m from an upslope building or level
building;
(ii) If primary treated effluent to be no less than 4m plus 1m for every degree of average
gradient from a downslope building;
(iii) If secondary treated effluent and subsurface application, no less than 2m plus 0.25m for every degree of average gradient from a
downslope building.
P1
a) The land application area is located so that
(i) the risk of wastewater reducing the
bearing capacity of a building’s
foundations is acceptably low.; and
(ii) is setback a sufficient distance from a
downslope excavation around or
under a building to prevent
inadequately treated wastewater
seeping out of that excavation
Complies with A1 (b) (i) Land application area will be located with a minimum separation distance of 3m from an upslope or level building.
A2 P2 Complies with A2 (a) Land application area located > 100m from downslope surface water
Horizontal separation distance from downslope Horizontal separation distance from downslope surface water to a land application area must comply surface water to a land application area must with (a) or (b) comply with all of the following:
(a) be no less than 100m; or a) Setbacks must be consistent with AS/NZS
(b) be no less than the following: 1547 Appendix R;
(i) if primary treated effluent 15m plus 7m for
every degree of average gradient to
downslope surface water; or
b) A risk assessment in accordance with
Appendix A of AS/NZS 1547 has been
completed that demonstrates that the risk is
acceptable. (ii) if secondary treated effluent and subsurface
application, 15m plus 2m for every degree of average gradient to down slope surface water.
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
A3 P3 Complies with A3 (b) (i) Land application area will be located with a minimum separation distance of 1.5m from an upslope or level property boundary
Complies with A3 (b) (ii) Land application area will be located with a minimum separation distance of 2m of downslope property boundary.
Horizontal separation distance from a property Horizontal separation distance from a property boundary to a land application area must comply with boundary to a land application area must comply either of the following: with all of the following:
(a) be no less than 40m from a property boundary; (a) Setback must be consistent with AS/NZS or 1547 Appendix R; and
(b) be no less than: (b) A risk assessment in accordance with
(i) 1 .5m from an upslope or level property
boundary; and
(ii) If primary treated effluent 2m for every
degree of average gradient from a
downslope property boundary; or
(iii) If secondary treated effluent and subsurface application, 1.5m plus 1m for every degree of average gradient from a downslope property boundary.
Appendix A of AS/NZS 1547 has been
completed that demonstrates that the risk is
acceptable.
A4
Horizontal separation distance from a downslope
bore, well or similar water supply to a land
application area must be no less than 50m and not be
within the zone of influence of the bore whether up or
down gradient.
P4
Horizontal separation distance from a downslope
bore, well or similar water supply to a land
application area must comply with all of the
following:
(a) Setback must be consistent with AS/NZS
1547 Appendix R; and
(b) A risk assessment completed in accordance
with Appendix A of AS/NZS 1547
demonstrates that the risk is acceptable
Complies with A4 No bore or well identified within 50m
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
A5
Vertical separation distance between groundwater
and a land application area must be no less than:
(a) 1.5m if primary treated effluent; or
(b) 0.6m if secondary treated effluent
P5
Vertical separation distance between
groundwater and a land application area must
comply with the following:
(a) Setback must be consistent with AS/NZS
1547 Appendix R; and
(b) A risk assessment completed in accordance
with Appendix A of AS/NZS 1547 that
demonstrates that the risk is acceptable
Complies with A5 (a) No groundwater encountered
A6
Vertical separation distance between a limiting layer
and a land application area must be no less than:
(a) 1.5m if primary treated effluent; or
(b) 0.5m if secondary treated effluent
P6
Vertical setback must be consistent with
AS/NZS1547 Appendix R.
Complies with A6 (a) No limiting layer identified
A7 P7
nil A wastewater treatment unit must be located a
sufficient distance from buildings or neighbouring
properties so that emissions (odour, noise or
aerosols) from the unit do not create an
environmental nuisance to the residents of those
properties
Complies
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
AS1547:2012 – Loading Certificate – Septic System Design
This loading certificate sets out the design criteria and the limitations associated with use of the
system.
Site Address: Lot 15, 10 Pardalote Close, Opossum Bay
System Capacity: 6 people @ 120L/person/day
Summary of Design Criteria
DLR: 25L/m2/day.
Absorption area: 30m2
Reserve area location /use: assigned – more than 100% available
Water saving features fitted: Standard fixtures
Allowable variation from design flows: 1 event @ 200% daily loading per quarter
Typical loading change consequences: Expected to be minimal due to capacity of system and site
area (provided loading changes within 25% of design)
Overloading consequences: Continued overloading may cause hydraulic failure of the absorption
area and require upgrading/extension of the area. Risk considered acceptable due to visible signs of
overloading and owner monitoring.
Underloading consequences: Lower than expected flows will have minimal consequences on
system operation unless the house has long periods of non occupation. Under such circumstances
additional maintenance of the system may be required. Risk considered acceptable.
Lack of maintenance / monitoring consequences: Issues of underloading/overloading and
condition of the absorption area require monitoring and maintenance, if not completed system failure
may result in unacceptable health and environmental risks. Septic tank de-sludging must also be
monitored to prevent excessive sludge and scum accumulation. Monitoring and regulation by the
property owner required to ensure compliance.
Other operational considerations: Owners/occupiers must be aware of the operational
requirements and limitations of the system, including the following; the absorption area must not be
subject to traffic by vehicles or heavy stock and should be fenced if required. The absorption area
must be kept with adequate grass cover to assist in evapotranspiration of treated effluent in the
absorption trenches. The septic tank must be desludged at least every 3 years, and any other
infrastructure such as septic tank outlet filters must also be cleaned regularly (approx. every 6
months depending upon usage). Foreign materials such as rubbish and solid waste must be kept out
of the system.
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Director of Building Control – Date Approved 1 July 2017 Building Act 2016 - Approved Form No. 55
CERTIFICATE OF QUALIFIED PERSON – ASSESSABLE ITEM Section 321
To: Wilson Homes Owner /Agent
250 Murray Street Address
Hobart 7000 Suburb/postcode
Qualified person details:Qualified person: John-Paul CummingAddress: 29 Kirksway Place Phone No: 03 6223 1839
Battery Point 7004 Fax No:
Licence No: AO999 Email address: [email protected]
Qualifications andInsurance details:
Certified Professional Soil Scientist (CPSS stage 2)
(description from Column 3 of the Director's Determination - Certificates by Qualified Persons for Assessable Items
Speciality area of expertise:
AS2870-2011 Foundation Classification
(description from Column 4 of the Director's Determination - Certificates by Qualified Persons for Assessable Items)
Details of work:Address: Lot 15, 10 Pardalote Close Lot No:
Opossum Bay 7023 Certificate of title No: 177924/15
The assessable item related to this certificate:
Classification of foundation Conditions according to AS2870-2011
(description of the assessable item being certified) Assessable item includes – - a material;- a design- a form of construction- a document- testing of a component, building
system or plumbing system- an inspection, or assessment,
performed
Certificate details:Certificate type: Foundation Classification (description from Column 1 of
Schedule 1 of the Director's Determination - Certificates by Qualified Persons for Assessable Items n)
This certificate is in relation to the above assessable item, at any stage, as part of - (tick one)
building work, plumbing work or plumbing installation or demolition work ☒or
a building, temporary structure or plumbing installation: ☐
Form 55
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Director of Building Control – Date Approved 1 July 2017 Building Act 2016 - Approved Form No. 55
In issuing this certificate the following matters are relevant –
Documents: The attached soil report for the address detailed above in 'details of Work'
Relevantcalculations: Reference the above report.
References: AS2870-2011 residential slabs and footingsAS1726-2017 Geotechnical site investigationsCSIRO Building technology file – 18.
Substance of Certificate: (what it is that is being certified)
Site Classification consistent with AS2870-2011.
Scope and/or LimitationsThe classification applies to the site as inspected and does not account for future alteration to foundation conditions as a result of earth works, drainage condition changesor variations in site maintenance.
I, John-Paul Cumming certify the matters described in this certificate.Signed: Certificate No: Date:
Qualified person: J2746 04/12/2020
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Director of Building Control - date approved: 2 August 2017 Building Act 2016 - Approved Form No 35
CERTIFICATE OF THE RESPONSIBLE DESIGNER Section 94Section 106Section 129Section 155
To: Wilson Homes Owner name
250 Murray Street Address
Hobart 7000 Suburb/postcode
Designer details:Name:
John-Paul CummingCategory: Bld. Srvcs. Dsgnr. -
Hydraulic
Business name: Geo-Environmental Solutions Phone No: 03 6223 1839
Business address: 29 Kirksway Place
Battery Point 7004 Fax No: N/A
Licence No: CC774A Email address: [email protected]
Details of the proposed work:
Owner/Applicant Wilson Homes Designer’s projectreference No. J2746
Address: Lot 15, 10 Pardalote Close Lot No: 177924/15Opossum Bay 7023
Type of work: Building work Plumbing work X (X all applicable)
Description of work:On-site wastewater management system - design (new building / alteration /
addition / repair / removal / re-erection water / sewerage / stormwater / on-site wastewater management system / backflow prevention / other)
Description of the Design Work (Scope, limitations or exclusions): (X all applicable certificates)
Certificate Type: Certificate Responsible Practitioner Building design Architect or Building Designer
Structural design Engineer or Civil Designer
Fire Safety design Fire Engineer
Civil design Civil Engineer or Civil Designer
Hydraulic design Building Services Designer
Fire service design Building Services Designer
Electrical design Building Services Designer
Mechanical design Building Service Designer
Plumbing design Plumber-Certifier; Architect, Building Designer or Engineer
Other (specify)
Deemed-to-Satisfy: Performance Solution: (X the appropriate box)
Other details:
Dual-purpose septic tank and onsite absorption
Design documents provided:
Form 35
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Director of Building Control - date approved: 2 August 2017 Building Act 2016 - Approved Form No 35
The following documents are provided with this Certificate –Document description:Drawing numbers: Prepared by: Geo-Environmental Solutions Date: Dec-20
Schedules: Prepared by: Date:
Specifications: Prepared by: Geo-Environmental Solutions Date: Dec-20
Computations: Prepared by: Date:
Performance solution proposals: Prepared by: Date:
Test reports: Prepared by: Geo-Environmental Solutions Date: Dec-20
Standards, codes or guidelines relied on in design process:AS1547-2012 On-site domestic wastewater management.
AS3500 (Parts 0-5)-2013 Plumbing and drainage set.
Any other relevant documentation:
Geo-Environmental Assessment - Lot 15, 10 Pardalote Close, Opossum Bay 712845 - Dec-20 - Lot 15, 10 Pardalote Close, Opossum Bay 712845 - Dec-20
Attribution as designer:I John-Paul Cumming, am responsible for the design of that part of the work as described in this certificate;
The documentation relating to the design includes sufficient information for the assessment of the work in accordance with the Building Act 2016 and sufficient detail for the builder or plumber to carry out the work in accordance with the documents and the Act;
This certificate confirms compliance and is evidence of suitability of this design with the requirements of the National Construction Code.
Name: (print) Signed Date
Designer: John-Paul Cumming 04/12/2020
Licence No: CC774A
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
Director of Building Control - date approved: 2 August 2017 Building Act 2016 - Approved Form No 35
Assessment of Certifiable Works: (TasWater)
Note: single residential dwellings and outbuildings on a lot with an existing sewer connection are not considered to increase demand and are not certifiable.If you cannot check ALL of these boxes, LEAVE THIS SECTION BLANK. TasWater must then be contacted to determine if the proposed works are Certifiable Works.
I confirm that the proposed works are not Certifiable Works, in accordance with the Guidelines for TasWater CCW Assessments, by virtue that all of the following are satisfied:
x The works will not increase the demand for water supplied by TasWater
x The works will not increase or decrease the amount of sewage or toxins that is to be removed by, or discharged into, TasWater’s sewerage infrastructure
x The works will not require a new connection, or a modification to an existing connection, to be made to TasWater’s infrastructure
x The works will not damage or interfere with TasWater’s works
x The works will not adversely affect TasWater’s operations
x The work are not within 2m of TasWater’s infrastructure and are outside any TasWater easement
x I have checked the LISTMap to confirm the location of TasWater infrastructure
x If the property is connected to TasWater’s water system, a water meter is in place, or has been applied for to TasWater.
Certification:
I .......... John-Paul Cumming........................ being responsible for the proposed work, am satisfied that the works described above are not Certifiable Works, as defined within the Water and Sewerage Industry Act 2008, that I have answered the above questions with all due diligence and have read and understood the Guidelines for TasWater CCW Assessments.Note: the Guidelines for TasWater Certification of Certifiable Works Assessments are available at: www.taswater.com.au
Name: (print) Signed Date
Designer: John-Paul Cumming 04/12/2020
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
ABSORPTION TRENCH1 x 20m x 1.5m x 0.6m
DUAL-PURPOSE SEPTIC TANK(MIN 3000L)
100% RESERVE AREA
Wastewater system:
Dual-purpose septic tank (min 3000L)
Absorption Trench1 x 15m x 2m x 0.6m
Min 3m from upslope buildingsMin 6m from downslope buildingsMin 1.5m from upslope or level boundariesMin 2m from downslope boundary Min 100m from downslope surface water
Refer to GES report
29 Kirksway Place Battery PointT| 62231839 E| [email protected]
4/12/2020
2m min
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
86 Queen Street, Sandy BayT| 62231839 E| [email protected]
Do not scale from these drawings.Dimensions to take precedenceover scale.
0.60
m
1.20 m
0.05 m0.15 m
90 - 100 mm DIA SLOTTED PIPEWITH GEOTEXTILE COVERING
20 mm AGGREGATE(400 mm DEEP)
FINISHED SURFACE OF SANDY LOAM50 mm MIN ABOVE NATURAL UPSLOPE AND150 mm MIN ABOVE AGGREGATE
NATURAL SOIL SURFACE
GEOTEXTILE GEOTEXTILE GEOTEXTILE GEOTEXTILE GEOTEXTILE OR FILTERCLOTH COVERING
Design notes:
1. Absorption trench dimensions of up to 20m long by 0.6m deep by 2m wide.2. Base of trenches to be excavated level and smearing and compaction avoided.3. Lower 400mm of bed to be filled with 20mm drainage aggregate and slotted 100mm distribution pipes packed into upper 100mm of aggregate4. Final finished surface with sandy loam from on site to be 100 mm above natural surface to allow for settlement.5. Construction on slopes up to 20% to allow trench depth range 650mm upslope edge to 450mm on down slope edge.6. On slopes over 5% the sandy loam cover should be 75-100mm above natural with a toes no less than 500mm in length to avoid surface wateraccumulation (up slope ag drain also recommended to divert surface water flows).7.The distribution pipe grid must be absolutely level to allow even distribution of effluent around the absorption area – it is recommended that thelevel be verified by running water into the system before backfilling and commissioning the trench 8.The slotted 90-100mm PVC distribution pipes must be slotted at “8 and 4 o’clock” when looking at the pipe section end-on, with the slots runninglevel along the horizontal length of the pipe – please see figure 2 – or commercially available pre-slotted PVC pipe utilised9.All works on site to comply with AS3500 and Tasmanian Plumbing code.
Absorption Trench Design- Slotted Pipe
2.00 m
INSPECTION OPENING
Inlet from septic tank
29 Kirksway Place, Battery PointT| 62231839 E| [email protected]
0.45
m
1.00 m
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682
86 Queen Street, Sandy BayT| 62231839 E| [email protected]
Do not scale from these drawings.Dimensions to take precedenceover scale.
Design notes:
1. Absorption trench dimensions of up to 20m long by 0.55m deep by 1.2m wide.2. Base of trenches to be excavated level and smearing and compaction avoided.3. Lower 400mm of bed to be filled with 20mm drainage aggregate and slotted 100mm distribution pipes packed into upper 100mm of aggregate4. Final finished surface with sandy loam from on site to be 100 mm above natural surface to allow for settlement.5. Construction on slopes up to 20% to allow trench depth range 650mm upslope edge to 450mm on down slope edge.6. On slopes over 5% the sandy loam cover should be 75-100mm above natural with a toes no less than 500mm in length to avoid surface wateraccumulation (up slope ag drain also recommended to divert surface water flows).7.The distribution pipe grid must be absolutely level to allow even distribution of effluent around the absorption area – it is recommended that thelevel be verified by running water into the system before backfilling and commissioning the trench 8.The slotted 90-100mm PVC distribution pipes must be slotted at “8 and 4 o’clock” when looking at the pipe section end-on, with the slots runninglevel along the horizontal length of the pipe – please see figure 2 – or commercially available pre-slotted PVC pipe utilised9.All works on site to comply with AS3500 and Tasmanian Plumbing code.
Absorption Trench Design- Slotted Pipe
Cross section:
Slotted 90-100mm distributionpipe-slots at "8 and 4 O'clock "
Top view of Trench:Inlet from septictank
Slotted 90-100mm pvc pipe @ 1m spacing- connected with 90degree corner joins- 500mm spacing from ends of trench
200 mm
100
mm
50 mm
Side View of Pipe:
Slots min 50mm in lengthPipe diameter90-100mm
29 Kirksway Place, Battery PointT| 62231839 E| [email protected]
Version: 1, Version Date: 20/07/2021Document Set ID: 4618682