12
Software Release Notes Software Versions: 3.2.41 Embedded Software 3.2.325 Portal Software P/N 260-668060-001 Rev 021 20 January 2006

Eclipse Software Release Notes 3.2.41

Embed Size (px)

Citation preview

Page 1: Eclipse Software Release Notes 3.2.41

Software Release Notes Software Versions: 3.2.41 Embedded Software

3.2.325 Portal Software

P/N 260-668060-001 Rev 021 20 January 2006

Page 2: Eclipse Software Release Notes 3.2.41

ii

Copyright © 2006 by Stratex Networks. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, magnetic, optical, chemical, manual or otherwise, without the prior written permission of Stratex Networks.

DISCLAIMER

Stratex Networks makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties or merchantability or fitness for any particular purpose. Further, Stratex Networks reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Stratex Networks to notify any person of such revision or changes. TECHNICAL SUPPORT If you require technical assistance or if you have discovered a product issue, please contact the Technical Help Desk nearest to you as soon as possible. Their contact details are shown below:

San Jose, CA Stratex Networks 120 Rose Orchard Way San Jose, California 95134 -1358 U.S.A. 1800 3629 283 (US Based) +1 408 944 3602 (English) +1 408 944 3564 (Spanish) [email protected]

United Kingdom Stratex Networks 4 Bell Drive Hamilton International Technology Park Blantyre, Scotland, G72 0FB UNITED KINGDOM +44 1698 717 230 [email protected]

Philippines Stratex Networks Bldg 10 Unit B, Philexcel Industrial Park Clark Special Economic Zone Clark Field Pampanga PHILIPPINES +63 45 599 5192 [email protected]

Clark, Philippines

Hamilton, Scotland

San Jose, USA

Page 3: Eclipse Software Release Notes 3.2.41

iii

Table of Contents

Scope and Purpose .......................................................................................................................................................1

Software Introduction .....................................................................................................................................................1

Supported Functionality .................................................................................................................................................2

Compatibility ..................................................................................................................................................................4 Eclipse Hardware Supported ..............................................................................................................................4

Operating Systems Supported............................................................................................................................6

Computer Hardware Supported ..........................................................................................................................6

Regional Settings Supported ..............................................................................................................................7

Closed Field Issues........................................................................................................................................................7

Closed Significant Issues ...............................................................................................................................................8

Portal and Embedded Compatibility History...................................................................................................................8

Important Notes .............................................................................................................................................................8

Page 4: Eclipse Software Release Notes 3.2.41

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

P/N 260-668060-001 Rev 021, 20 January 2006 Page 1

Scope and Purpose

This document provides software release information on supported functionality, compatibility, and known customer affecting issues, relating to the released software versions.

The intended users of this document are:

Stratex Networks (SN) Customers SN Value Added Resellers SN Value Added Service Providers SN Product Support staff SN Field Service staff

Software Introduction

This software has been made available for customer release. In addition to previously supported hardware and functionality it now provides additional support for:

• IDU 300 155o 1+1 • DAC 3xE3/DS3M • ODU 300 SP • Additional ODU 300 HP frequencies • Additional RAC 40, RAC 3X, IDU 300 ES +8xE1 capacities • DAC ES/GE priority mapping, transport channel and VLAN tagging • Customer naming of system functions • Software rollback and reset • Network time protocol • Event Log and Link History clear down • Improved Protection Diagnostics diagram • Alarm action severity thresholds • Default gateway support

The following table lists the software details for this release.

Product Part Number Version Number

Stratex Reference Number

Eclipse Embedded Software 275-250219-030241 3.2.41 1341-063

Eclipse Portal Software 280-200010-0302325 3.2.325 0184-069

This release is supported by ProVision Element Manager System software version 5.6.1 with the following exceptions:

• Some IDU300 155o 1+1 or DAC 3xE3/DS3M events will not be processed

• ODU 300 SP bulk software download is not supported and RF values are not displayed in the configuration viewer

Page 5: Eclipse Software Release Notes 3.2.41

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

P/N 260-668060-001 Rev 021, 20 January 2006 Page 2

Supported Functionality

The following headings list functionality that is currently supported by 3.2.41 embedded and 3.2.325 Portal software. New functionality is highlighted in bold italics.

Configuration

Populate information fields such as terminal name, site name, etc View expected plug-in layout Configure frequency, power, modulation and capacity Configure tributary interface parameters Configure DAC ES ports Configure circuits Configure IP routing Set radio date and time Manage software versions and download View active license and download license Configure ring protection Configure dynamic routing View equipment part numbers and serial numbers Configure custom T/R splits Configure trap destinations Configure XP4 compatibility mode Configure ring wrap and unwrap criteria Configure system function names

Performance and Monitoring

View RSL View G.826 15-minute and daily registers View history graphs and reports View Real time G.826 View event log and view event history View temperature values View forward power data View available supply voltages View DAC ES Ethernet performance statistics Estimated BER (G.821) performance monitor for link history reports

Diagnostics

Activate tributary/AUX line facing loop back Activate tributary/AUX radio facing loop back Activate digital loop back Activate IF loop back Activate circuit loopbacks Transmit AIS on individual tributaries Enable TX PA mute View system summary View problem and severity indicators Disable ATPC Enable DAC PRBS Configure safety timers View and control ring status PRBS tester reset control Perform software rollback and reset Clear event log

Page 6: Eclipse Software Release Notes 3.2.41

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

P/N 260-668060-001 Rev 021, 20 January 2006 Page 3

Protection Support Equipment protection supported Hitless path protection supported Unidirectional ring protection supported Optical tributary protection supported

Communications & Networking

Serial interface supported SNMPv2 interface supported Ethernet interface support NMS overhead channel supported Static routing supported OSPF routing supported RIP II routing supported Configure default gateway

Miscellaneous Features

Manufacturing details supported Watch dog supported ATPC supported Portal auto-version supported (upload Portal from radio) Soft reset without interrupting traffic As-built report supported Data file to send to Stratex Help Desk

Alarms

Alarm hierarchy supported User configurable alarm thresholds Alarm I/O supported

Logs

Event log operational Informational event log entries Event log notes

Security

Features controlled by license key Portal user security Auto-login support for ProVision

Software Loading

Software loading – internal users only Software loading – customer usable

Portal Help

Customer support details About Eclipse Portal Eclipse Help integration with alarm troubleshooting entries

Page 7: Eclipse Software Release Notes 3.2.41

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

P/N 260-668060-001 Rev 021, 20 January 2006 Page 4

Compatibility

Eclipse Hardware Supported

The following table details the hardware that is supported by this software and corresponding part numbers.

Hardware Type Part Number Description

IDC EXC-001, EXC-002 Indoor Chassis, 1RU

NCC EXN-001, EXN-002 Node Controller Card

FAN EXF-001, EXF-002 Fan Card

INU EXX-000-001, EXX-000-002 Intelligent Node Unit, 1RU

INUe EXX-000-201 Intelligent Node Unit, Extended

NPC EXS-001 Node Protection Card

IDU 100 8x EXB-081-001 Indoor Unit, 8xE1, QPSK

IDU 100 16x EXB-161-001 Indoor Unit, 16xE1, QPSK

IDU 100 20x EXB-201-001 Indoor Unit, 20xE1, Hot Standby

IDU 300 8x EXG-081-001 Indoor Unit, 8xE1/DS1

IDU 300 20x EXG-201-001 Indoor Unit, 20xE1/DS1, Hot Standby

IDU 300 ES EXG-211-001 Indoor Unit, Fast Ethernet + 8xE1/DS1

AUX EXA-001 Auxiliary and alarm I/O card

DAC 4x EXD-040-001 Data Access Card, 4xE1/DS1

DAC 16x EXD-160-001 Data Access Card, 16xE1/DS1

DAC 155o EXD-152-001 Data Access Card, 1xSTM-1/OC3, Optical

DAC 155oM EXD-153-001 Data Access Card, 1xSTM-1/OC3 Multiplexed to 63E1/84DS1, Optical

DAC ES EXD-171-001 Data Access Card, 10/100baseT Fast Ethernet

DAC GE EXD-180-001 Data Access Card, Gigabit Ethernet

DAC 2x155e EXD-254-001 Data Access Card, 2xSTM-1/OC3, Electrical

DAC 3xE3/DS3 EXD-330-001 Data Access Card, 3xE3/DS3, tributary protection

RAC 10 EXR-011-001 Radio Access Card, ODU 100

RAC 10 v2 EXR-011-002 Radio Access Card, ODU 100 version 2

RAC 30 EXR-999-001, EXR-999-002 Radio Access Card, ODU 300

RAC 40 EXR-966-001 Radio Access Card, ODU 300, 64xE1, 1xSTM-1/OC3, XPIC

RAC 3X EXR-900-001 Radio Access Card, ODU 300, 1xSTM1/OC3 and 2xSTM1/OC3

Page 8: Eclipse Software Release Notes 3.2.41

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

P/N 260-668060-001 Rev 021, 20 January 2006 Page 5

Hardware Type Part Number Description

ODU 100 ECS-07-0154-* ECS-07-0161-* ECS-07-0245-* ECS-08-0119-* ECS-08-0126-* ECS-08-0151-* ECS-08-0266-* ECS-08-0311-* ECS-08-0305-* ECS-11-0490-* ECS-11-0500-* ECS-11-0530-* ECS-13-0266-* ECS-15-0315-* ECS-15-0420-* ECS-15-0490-* ECS-15-0644-* ECS-15-0728-* ECS-18-0340-* ECS-18-1010-* ECS-18-1092-* ECS-23-0600-* ECS-23-1008-* ECS-23-1200-* ECS-23-1232-* ECS-26-1008-* ECS-31-0225-* ECS-31-0410-* ECS-31-0450-* ECS-31-0490-* ECS-31-1008-* ECS-31-1975-* ECS-32-0812-* ECS-38-1260-*

Frequency bands supported are:

7, 8, 11, 13, 15, 18, 23, 26, 31, 32, 38 GHz Note: the software supports these frequency bands/splits however the hardware option may not exist.

* All numbers supported

ODU 300 EP & SP

E**-05-0300-* E**-05-0312-* E**-06-0252-* E**-06-0160-* E**-06-0170-* E**-06-0340-* E**-07-0154-* E**-07-0161-* E**-07-0168-* E**-07-0196-* E**-07-0245-* E**-08-0119-* E**-08-0126-* E**-08-0151-* E**-08-0208-* E**-08-0266-* E**-08-0305-* E**-08-0310-* E**-08-0311-* E**-11-0490-* E**-11-0500-* E**-11-0530-* E**-13-0266-* E**-15-0315-* E**-15-0420-* E**-15-0475-* E**-15-0490-* E**-15-0644-* E**-15-0728-* E**-18-0340-* E**-18-1008-* E**-18-1010-* E**-18-1092-* E**-18-1120-* E**-18-1560-* E**-23-0600-* E**-23-1008-* E**-23-1200-* E**-23-1232-* E**-26-0800-* E**-26-0855-* E**-26-1008-* E**-28-0450-* E**-28-1008-* E**-31-0225-* E**-31-1975-* E**-32-0812-* E**-38-0700-* E**-38-1000-* E**-38-1260-*

Frequency bands supported are:

5, 6, 7, 8, 11, 13, 15, 18, 23, 26, 28, 31, 32, 38 GHz Note: the software supports these frequency bands/splits however the hardware option may not exist.

* All numbers & letters supported

ODU 300 HP EAH-06-0252-* EAH-06-0160-* EAH-06-0170-* EAH-06-0180-* EAH-06-0340-* EAH-07-0154-* EAH-07-0161-* EAH-07-0245-* EAH-08-0119-* EAH-08-0126-* EAH-08-0152-* EAH-08-0208-* EAH-08-0266-* EAH-08-0306-* EAH-08-0310-* EAH-08-0311-* EAH-11-0490-* EAH-11-0500-* EAH-11-0530-* EAH-15-0315-* EAH-15-0420-* EAH-15-0475-* EAH-15-0490-* EAH-15-0644-* EAH-15-0728-* EAH-18-0340-* EAH-18-1010-* EAH-18-1092-* EAH-18-1120-* EAH-18-1560-* EAH-23-0600-* EAH-23-1008-* EAH-23-1200-* EAH-23-1232-*

Frequency bands supported are:

6, 7, 8, 11, 15, 18, 23 GHz Note: the software supports these frequency bands/splits however the hardware option may not exist.

* All numbers supported

Page 9: Eclipse Software Release Notes 3.2.41

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

P/N 260-668060-001 Rev 021, 20 January 2006 Page 6

Operating Systems Supported

The following table details the supported Operating Systems.

Operating System Notes

Windows XP Pro (SP1) Refer to Eclipse User Manual for XP support information

Windows 2000 Pro (SP3) -

Windows NT 4.0 -

Windows 98 -

Computer Hardware Supported The following table details the minimum hardware specifications required to operate Portal.

Attributes Minimum Specifications

Processor P3, 500 MHz

RAM 256 MB

HD space (install and operate) 80 MB

Monitor adaptor SVGA

Monitor display resolution 800 x 600

Monitor colours 256

Mouse Yes Note: ATI video cards installed with a ‘Catalyst driver’ set earlier than 4.9 will cause the Portal performance page to stop working if the screen-saver activates. The workaround is to install the latest video drivers from the video card manufacturer.

Page 10: Eclipse Software Release Notes 3.2.41

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

P/N 260-668060-001 Rev 021, 20 January 2006 Page 7

Regional Settings Supported Portal supports the following locales and there are no known limitations: Albanian, Belorussian, Bulgarian, Catalan, Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hebrew, Hungarian, Icelandic, Italian, Japanese, Korean, Latvian, Lithuanian, Macedonian, Norwegian, Polish, Portuguese, Romanian, Russian, Serbian, Serbo-Croatian, Slovak, Slovenian, Spanish, Ukrainien. The following table details known regional settings limitations.

Locales Known Limitations

Arabic The calendar does not display the day of the week correctly

Chinese The date format is not consistent in event browser, the calendar does not display the day of the week correctly, and the alarms page is larger than 800 x 600 resolution

Hindi The alarms page is larger than 800 x 600 resolution

Swedish Commas are displayed instead of decimal points when entering the TR/RX spacing and TX/RX frequency. Portal will accept commas when the user enters TX/RX frequency, however it will not accept commas for the TX/RX spacing.

The workaround is to use decimal points.

Thai Alarms page is larger than 800 x 600 resolution

Turkish Some event log entries in the event browser and link history pages may not be displayed

Closed Field Issues

The following table lists field issues that have been fixed by this release.

Trouble Ticket # Issue Description

C-00093901 A RAC 40 would not reliably lock all demodulators following a power cycle or following a software download.

C-00092767 Programming a default route into the static routing did not appear to work correctly.

C-00090704 Portal allowed the user to change the TX Power outside of the actual ODU 100 power range.

C-00089917 Offline ODU 300 faults were not being displayed in Portal.

Page 11: Eclipse Software Release Notes 3.2.41

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

P/N 260-668060-001 Rev 021, 20 January 2006 Page 8

Closed Significant Issues

The following table lists significant issues that were discovered during development/testing and have been fixed by this release.

Software Type Issue Description

Embedded Portal was unable to detect hardware changes when a ODU300, ODU300 SP, or ODU 300 HP was interchanged between a single IDU or INU. The workaround was to refresh Portal.

Portal Portal notes fields in the event log displayed misleading text. An example was “Ring0 SECONDARY path wrapped because of TX path failure”, where the ‘Ring0’ displayed radio context information and not user defined information.

Portal and Embedded Compatibility History

Embedded Software Version Matching Portal Software Version

2.1.18 and later (Portal auto-version supported) 2.1.1, Build 2112 and later

2.0.44 2.0.1, Build 2018

1.0.29 1.0.1, Build 1923

0.10.31 0.10.1, Build 1660

0.10.20 0.10.1, Build 1660 or 1722

0.9.32 0.9.2, Build 1358

Important Notes

1. Traffic may be affected when upgrading software between two specific versions of software. Contact a Stratex Networks Technical Help desk for details, contact details are on page ii of these release notes.

2. Static routes should not be entered when using OSPF. 3. When upgrading from version 2.5.63 or earlier to version 3.0.73 or later, an interim version of

software must be loaded first. The interim versions that can be used are 2.6.58, 2.8.5, 2.8.6, 2.9.51, 2.9.66, or 2.9.69.

4. Portal Help integration requires Stratex Help revision 014 or higher. Stratex Help is a standalone help program that is installed separately to Portal, it can be found on the Eclipse Setup installation CD.

5. A license upgrade requires a power cycle if the backplane type changes.

Page 12: Eclipse Software Release Notes 3.2.41

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

P/N 260-668060-001 Rev 021, 20 January 2006 Page 9

6. A power cycle or a RAC reinsertion is required if a capacity change exceeds the license capacity size.

7. To reduce the traffic outage time during a software load of a IDU 100 1+1 protected radio the following steps should be observed:

a. Lock all units to TX/RX on the Primary and load only to the high band Secondary IDU/ODU pair

b. Keeping all units TX/RX locked on the Primary, load only to the low band Secondary IDU/ODU pair

c. Switch all units to TX/RX on the Secondary and lock them there. d. Keeping all units TX/RX locked on the Secondary, load only to the high band Primary IDU/ODU pair. e. Keeping all units TX/RX locked on the Secondary, load only to the low band Primary IDU/ODU pair f. Switch all units back to TX/RX auto

Stratex Networks encourages its customers to report problems so we can resolve them as quickly as possible.

If you encounter a technical issue please contact us using the information on page ii of these Release Notes