eCADFEM - Installation Setup Christian Meyer

Stefan Halbritter

06/2016

eCADFEM - Installation Setup (29-09-2016) 1

Page 2: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Content

eCADFEM - Installation Setup (29-09-2016) 2

Section 1 - Technical Information

Section 2 - Installation

Section 3 - Usage

About this document • Please read the document completely

• Navigate: follow the Links to go to the specific theme

• Navigate: return to the last viewed page by pressing Alt + Arrow towards left

Page 3: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Part 1 – Technical Information

eCADFEM - Installation Setup (29-09-2016) 3

Prerequisites

• Capability and Access

• Software, Network Connection (Ports)

• Usage Recommendations

• Dial-In Method: User Authentication

• Dial-In Method: IP

Page 4: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 1 – Technical Information – Capability and Access

eCADFEM - Installation Setup (29-09-2016) 4

Capability

• eCADFEM provides CAE licenses on demand, and based on a permanent internet

connection. The usage is charged against a prepaid contingent.

Access

• eCADFEM requires one of the following dial-in methods to communicate with the

eCADFEM Server:

• Permanent Public Firewall-IP (provided by the customer)

• Or a User Authentication (12 digit authentication, generated by the eCADFEM-Team)

• The 12-digit user authentication will be generated by the eCADFEM-Team in the event you

may not be able to provide a permanent, public firewall IP for your dial-in.

Page 5: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 1 – Technical Information – Software and Network Connection (Ports)

eCADFEM - Installation Setup (29-09-2016) 5

Software

• ANSYS Version 12 …. 17.2

• And/or: optiSLang (DYNARDO), Rocky DEM (ESSS)

Network Connection (Ports)

• Internet Connection

• Open the Ports 1056 and 2325 (ANSYS and Maxwell)

TCP

Outgoing only

• Open the Port 2020 (DYNARO optiSLang 5) or 1056 (ANSYS optiSLang 5.1.1)

TCP

Outgoing only

• Open the Port 1516 (Rocky DEM (ESSS))

TCP

Outgoing only

Page 6: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 1 – Technical Information – Usage Recommendations (1)

eCADFEM - Installation Setup (29-09-2016) 6

Regular Monitoring: Examine the usage by monitoring the inrements regularly. • Logging in on the password protected customer area on our eCADFEM Portal www.ecadfem.com

provides you the usage history as well as the very licenses that are currently checked out (Aktuelle Nutzung BETA, also to be monitored with the Viewer-Login). Please keep in mind that the sessions listed in the menue „Aktuelle Nutzung“ will be traceable after the licenses will have been used for several times. This is due to an automated rule compilation.

• Sessions: The day‘s session history is automatically cumulated at midnight and is listed in the customer area the next morning.

• Aktuelle Nutzung: The current usage is displayed with an offset of 5 minutes.

Unattended APDL-Jobs: „ANSYS Batch" Jobs recommeded • Please find this option in the Mechanical APDL Product Launcher at "Simulation Environment".

The allocation is limited to the duration of the calcuation procedure. This helps to avoid unattended license usage (e.g. by interactive ANSYS Mechanical sessions).

Permanent Connection: The permanent connection to the eCADFEM License Server is mandatory throughout the entire license usage. • Also, please make sure that your router settings for TCP-Aging are set to greater than 7200

seconds. Minor standard settings of e.g. 300 seconds may lead to overlapping responses.

Using the License Allocation of the ANSYS Prep/Post & Solver Licenses (effective since Sept. 01, 2016)

Page 7: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 1 – Technical Information – User Authentication

eCADFEM - Installation Setup (29-09-2016) 7

User Authentication

• This 12-digit user authentication is necessary, in the event no permanent, public IP-address

can be assigned by your Internet-Service-Provider.

• The authentication will be generated by the eCADFEM-Team and is included in the email

confirming your eCADFEM activation.

• To use eCADFEM with this authentication, your IT has to create a new (!) user-account with

according permissions (local or domain account) by naming it this very 12-digit

authentication.

• Using eCADFEM will only be able by signing in on the computer(s) with this 12-digit

authentication, but not with the regular user login. The authentication can be used for one or

even for multiple computers.

eCADFEM Server Client

Internet

Page 8: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 1 – Technical Information – IP Dial-In (1)

eCADFEM - Installation Setup (29-09-2016) 8

IP Dial-In

• The IP that will be registered for your account has to be permanent and public. Dynamic IP

addresses as well as private IP addresses cannot be routed and can therefore not be used for

eCADFEM.

• If you use Load-Balancing, all of the permanent, public IP addresses have to be registered.

• You have to operate an ANSYS License Server locally.

• Previous ANSYS Releases: The use of the most recent License Manager is recommended

even when using previous ANSYS releases.

Important: If you operate local ANSYS licenses too, the license key has to be examined prior to the

update to insure compatibility. License keys that are not in current maintenance, may not be able to be

utilized with the updated license manager.

If you have any considerations, you are welcome to contact our eCADFEM-Team at [email protected]

or our CADFEM Support-Teams

Client Ansysli (+ FlexLM) eCADFEM Server

Internet LAN

Page 9: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 1 – Technical Information – IP Dial-In (2)

eCADFEM - Installation Setup (29-09-2016) 9

Environments with IP Dial-In

• eCADFEM only

Use: only eCADFEM licenses are used

Operational: only an ansysli-Server is operated, but no FlexLM

• eCADFEM in combination with local ANSYS Licenses

Use: eCADFEM licenses are used in combination with licenses from a local license server

Operational: a complete license server (Ansysli- and FlexLM Server) is operated

Client Ansysli (+ FlexLM) eCADFEM Server

Internet LAN

Page 10: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 2 – Installation

eCADFEM - Installation Setup (29-09-2016) 10

Installation

• User Authentication

• IP Dial-In: eCADFEM only

• IP Dial-In: eCADFEM + local licenses in combination

• Using optiSLang/optiSLang inside Workbench

• Proxy Server

Page 11: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 2 - Installation – User Authentication

eCADFEM - Installation Setup (29-09-2016) 11

Prerequisites

• ANSYS Client Installation – 17.2 (or earlier)

• New (!) user (lokal or domain account)

• Check open ports for this user: (TCP) 1056 and 2325 and respectively 2020, 2021, 1516

• Insert entries in file %ANSYSLIC_DIR% \ ansyslmd.ini

%ANSLIC_DIR% = C:\Programms\Ansys Inc\Shared Files\Licensing

1056

2325

ansyslmd.ini:

Internet

eCADFEM Server

portal.ecadfem.com Client

User Account: EcadUserXY12

principal setup

[email protected] [email protected]

Page 12: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 2 - Installation – IP Dial-In – eCADFEM only (1)

eCADFEM - Installation Setup (29-09-2016) 12

Prerequisites

• ANSYS Client Installation – 17.2 (or earlier)

• Local ANSYS License Server, with ANSYSLI_SERVER only

• Check open ports : (TCP) 1056 and 2325 and respectively 2021, 1516

• Insert entries in file %ANSYSLIC_DIR%\ ansyslmd.ini

%ANSLIC_DIR% = C:\Programms\Ansys Inc\Shared Files\Licensing

• Definition of an environment variable

Client Local Server:

Ansysli

LAN

1056

2325

Internet

eCADFEM Server

portal.ecadfem.com

Public IP Adress: ###.###.###.###

1056

2325

Next page

principal setup

Page 13: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 2 - Installation – IP Dial-In – eCADFEM only (2)

eCADFEM - Installation Setup (29-09-2016) 13

Entries in file %ANSYSLIC_DIR%\ansyslmd.ini (usually) %ANSLIC_DIR% = C:\Programms\Ansys Inc\Shared Files\Licensing

Definition of an environment variable environment variable (SYSTEM): FNP_IP_ENV=1

Definition of the global environment variable (SYSTEM):

FNP_IP_ENV=1 + ansyslmd.ini:

ANSYSLI_IP_OVERRIDE ANSYSLI_NOFLEX=1 ANSYSLI_SERVERS=2325@IhrServerHostname [email protected] [email protected]

Server:

ansyslmd.ini:

ANSYSLI_SERVERS=2325@IhrServerHostname [email protected] [email protected]

Client:

Page 14: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 2 - Installation – IP Dial-In – eCADFEM + local licenses (1)

eCADFEM - Installation Setup (29-09-2016) 14

Prerequisites

• ANSYS Client Installation – 17.2 (or earlier)

• Local ANSYS License Server (Ansysli + FlexLM)

• Check open ports : (TCP) 1056 and 2325 and respectively 2020, 2021, 1516

• Insert entries in file %ANSYSLIC_DIR%\ ansyslmd.ini

(usually) %ANSLIC_DIR% = C:\Programms\Ansys Inc\Shared Files\Licensing

• Definition of an environment variable

Client Local Server:

Ansysli + FlexLM

LAN

1056

2325

Internet

eCADFEM Server

portal.ecadfem.com

Public IP Adress: ###.###.###.###

1056

2325

Next page

principal setup

Page 15: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 2 - Installation – IP Dial-In – eCADFEM + local licenses (2)

eCADFEM - Installation Setup (29-09-2016) 15

Entries in file %ANSYSLIC_DIR%\ansyslmd.ini (usually) %ANSLIC_DIR% = C:\Programms\Ansys Inc\Shared Files\Licensing

Definition of a global environment variable Environment variable (SYSTEM): FNP_IP_ENV=1

Definition of the global environment variable (SYSTEM):

FNP_IP_ENV=1 +

ansyslmd.ini:

ANSYSLI_IP_OVERRIDE SERVER=1055@lokalerLicServerHostname ANSYSLI_SERVERS=2325@lokalerLicServerHostname [email protected] [email protected]

Server:

ansyslmd.ini:

SERVER=1055@lokalerLicServerHostname ANSYSLI_SERVERS=2325@IhrServerHostname [email protected] [email protected]

Client:

Page 16: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 2 – Installation – Using optiSLang / ANSYS optiSLang

eCADFEM - Installation Setup (29-09-2016) 16

ANSYS OptiSlang (starting with 5.1.1)

• Open the TCP Port 1056, outgoing only

OptiSLang 5 or before

• Open the TCP Port 2020, outgoing only

• Settings within the application OptiSLang

Specifying the license server by *.lic-file.

Create the file during installation on C:\ (C:\Programms\optislang_x.y.z\flowguide\license)

example for filename: license.lic

Content (example):

# License for OptiSLang

# Customer:

# Comment: ecadfem-Portal License

SERVER portal.ecadfem.com 00d0b7901800 2020

USE_SERVER

VENDOR sc_ag

Page 17: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 2 – Installation - Proxy-Server (TCP only)

eCADFEM - Installation Setup (29-09-2016) 17

ANSYS licensing does not support proxy-server for the time being

• Therefore, the ANSYS application via proxy server can only be done by a transparent port

forwarding.

• The incoming ANSYS client requests from the proxy server are directly forwarded to the

hostname of the eCADFEM-Portal (portal.ecadfem.com). The forwarding is done through

the TCP-Protocol (1056/2325).

• HTTP-Proxy forwarding is not possible.

• The response returns to higher ports, which are already opened for standard

communication. (Backroute has to be possible)

Page 18: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – Usage

eCADFEM - Installation Setup (29-09-2016) 18

Test

How to use the PrepPost – Solver License Allocation

• Workbench Settings

• RSM Settings

• Mechanical Editor Settings

• Project Schematic Settings

• Start Solution

How to avoid unattended usage

Prioritize eCADFEM towards local licenses

Diagnosis

Potential sources of error/malfunction

Page 19: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – Usage - Test

eCADFEM - Installation Setup (29-09-2016) 19

Functional Test

• Start Mechanical APDL

• Start a Workbench-Project, i.e. Mechanical Editor has to be open

The checked-out license is listed in the headline in sqare brackets

Prioritizing a local license can not be guaranteed in general

• Work-Arounds for selective license addressing

The order in which the licenses are addressed depends on

• The accessibility to the server respectively the response time of the local server compared

to the eCADFEM Server.

• And the hierarchy in the License Preferences (License Presettings)

Page 20: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – How to use the PrepPost – Solver License Allocation

eCADFEM - Installation Setup (29-09-2016) 20

ANSYS Mechanical license change as of Sept. 1, 2016

• ANSYS Mechanical Enterprise (ansys)

was splitted into:

ANSYS Mechanical Enterprise PrepPost (preppost) +

+ ANSYS Mechanical Enterprise Solver (meba)

ANSYS Workbench: Modified procedure on the client

• Mandatory settings

in ANSYS Workbench

in RSM (Remote Solve Manager)

in ANSYS Mechanical Editor– Solve Process Settings

• Solve

Out of the Mechanical Editor

Out of the Project Site

Page 21: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – PrepPost – Solver Licenses: Workbench Settings (1)

eCADFEM - Installation Setup (29-09-2016) 21

The following setting releases the PrepPost License promptly after

completion (cost optimization)

• Extras Options Mechanical: Release License for Pending Jobs = Always

Page 22: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – PrepPost – Solver Licenses: Workbench Settings (2)

eCADFEM - Installation Setup (29-09-2016) 22

License Preferences

• PrepPost Tab: ANSYS Mechanical Enterprise PrepPost prioritize as topmost

• Solver Tab: ANSYS Mechanical Enterprise PrepPost prioritize as topmost as well

• Solver Tab: ANSYS Mechanical Enterprise Solver right beneath

Also depending, if either a local or an eCADFEM license is requested, the according license has to be prioritized as topmost. In this regard, the Mechanical Editor uses the settings from the Solver Tab

Page 23: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – PrepPost – Solver Licenses: RSM Settings (1)

eCADFEM - Installation Setup (29-09-2016) 23

Solve Manager (RSM) Properties

• Open the RSM Admin Window:

START All Programs ANSYS 17.2 Remote Solve Manager RSM 17.2

• Right Mouse Button on My Computer

My Computer Set Password

• Enter Password (password for the suggested user)

• Remain until the Set Password window fades

My Computer Properties: Project Directory

• Create a directory on a local data partition

• Enter this new directory as Project Directory

Page 24: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – PrepPost – Solver Licenses: RSM Settings (2)

eCADFEM - Installation Setup (29-09-2016) 24

Compute Server Properties

• Right Mouse Button on Compute-Server localhost Properties

Working Directory Location: User Specified

Working Directory Path: enter the path

used for the Project Directory

Enlarge the window by clicking on more if needed

Set Maximum Number of Jobs on 1

Page 25: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – PrepPost – Solver Licenses: Mechanical Editor Settings (1)

eCADFEM - Installation Setup (29-09-2016) 25

Solve Process Settings in the Mechanical Editor

• Tools Sole Process Settings… My Computer (Background):

License: ANSYS Mechanical Enterprise Solver

Page 26: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – PrepPost – Solver Licenses: Mechanical Editor Settings (2)

eCADFEM - Installation Setup (29-09-2016) 26

Advanced Solver Properties (optional)

• Tools Solve Process Settings…

My Computer (Background): Advanced Properties…

Select Distribute Solution (if possible)

(= distributed (DMP))

Max. number of utilized cores: n (= Number of all CPU-Cores for Solution)

• ANSYS Mechanical Enterprise Solver occupies 2 cores (Standard)

• ANSYS HPC-Packs:

n < = 8 requires 1 HPC-Pack

n > 8 < = 32 require 2 HPC-Packs

n > 33 < = 128 require 3 HPC-Packs

License Queuing: Wait for Available License: selection not

mandatory for eCADFEM

Page 27: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – PrepPost – Solver Licenses: Project Settings

eCADFEM - Installation Setup (29-09-2016) 27

Analysis System Settings: Update Option: Submit to Remote Solve Manager

Solve Process Setting: My Computer, Background

Page 28: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – PrepPost – Solver Licenses: Start Solution

eCADFEM - Installation Setup (29-09-2016) 28

Start the Solution out of the Mechanical Editor

• PrepPost License remains occupied during the Solution

• Especially suitable for short-term solutions

• Start the Solution: Solve My Computer (Background)

Start the Solution out of the Project

• PrepPost License is only occupied for a short time

• Start the Solution

Unique Analysis

• Right Mouse Button on Solution Update

Combined Analysis

• Update

All combined analysis get updated

Page 29: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – How to avoid unattended usage

eCADFEM - Installation Setup (29-09-2016) 29

Unattended license usage may occur if

• Mechanical maintained active after the usage

• Batch Solve

• Or if processes have not been finished correctly

Monitoring of active licenses

• The Task Manager shows active ANSYS / CFX processes

ANSYS.exe

AnsMeshingServer.exe

AnsysWBU.exe

AnsysFWW.exe

• Important: unfinished processes can block returning the license correctly

• Python Scripts out of the project: please check the processes after completing the ANSYS

Workbench

PreEngine.exe

PreGui.ogl.exe

Cfx5pre.exe*32

SolverManager.exe

Cfx5solve.exe*32

PostEngine.exe

PostGui.ogl.exe

Cfx5post.exe*32

Page 30: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – Prioritize eCADFEM towards local licenses

eCADFEM - Installation Setup (29-09-2016) 30

The sole usage of eCADFEM licenses can be executed with specific Start Scripts

• Using those Start Scripts opresses the licenses from the local license server

• If a local ANSYSLI_SERVER is operated (IP Dial-In), the local hostname of the ANSYSLI_SERVERS has to be prioritzied i.e. to be listed first. E.g.: set ANSYSLI_SERVERS=2325@lokaleransysliserver;[email protected]

Start script for Windows

• ANSYS 17.1 APDL: @echo off set [email protected] set [email protected] set ANS_FLEXLM_DISABLE_DEFLICPATH=1 "%AWP_ROOT171%\CommonFiles\TCL\bin\%ANSYS_SYSDIR%\wish.exe" "%AWP_ROOT171%\CommonFiles\Launcher\launchermain.itcl“

• ANSYS Workbench 17.1: @echo off

set [email protected]

set [email protected]

set ANS_FLEXLM_DISABLE_DEFLICPATH=1

"%AWP_ROOT171%\Framework\bin\win64\runwb2.exe"

Page 31: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – Diagnosis

eCADFEM - Installation Setup (29-09-2016) 31

Verify the file entries in %ANSYSLIC_DIR%\ansyslmd.ini

Verify the outgoing ports

• in cmd-Shell:

telnet portal.ecadfem.com 1056

telnet portal.ecadfem.com 2325

• Output:

If you receive an error, the port may be blocked

This test does not verify any further restrictions within the Firewall communication.

Further blockings can be verified by deactivating the Firewall temporarily (if possible)

Processes in the Windows Task Manager

• ansysli_server.exe

• ansysli_monitor.exe

Any further questions please contact us at [email protected]

• Please include the following information in your email:

Diagnosis of the ANSLIC_ADMIN Utility as a file

ANSYS License Management Center > Diagnostics > Gather Diagnostic Information > Save To File

Page 32: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – Potential sources of error/malfunction (1)

eCADFEM - Installation Setup (29-09-2016) 32

Please verify wether all prerequisites are fulfilled

Most local obstacles are:

• IP Dial-In

The registered IP address is not transmitted or your dial-in is executed with a different IP

Please have your IT check the permanent, public IP of your Firewall

Verify the setting of the Environment Variable FNP_IP_ENV=1

Verify the entry of the local Ansysli Servers in the ansyslmd.ini

• Blocking of the local ANSYS license components by a local Security Software (

[Windows] Firewall / Enpoint Protection, etc.)

Solution: allow communication for blocked programs

• Blocking of mandatory Ports by local Security Software (Windows Firewall !)

Solution: activate blocked Ports

• portal.ecadfem.com nor properly resolved in DNS

Solution: apply correct DNS settings respectively by static host-file entry

• License Preferences are set incorrectly

Solution: move one of the activated eCADFEM products to the topmost in the License Preferences,

and restart the application

Page 33: eCADFEM - Hinweise zum Setup · ANSYS Mechanical Enterprise PrepPost (preppost) + + ANSYS Mechanical Enterprise Solver (meba) ANSYS Workbench: Modified procedure on the client

© CADFEM 2016

Section 3 – Potential sources of error/malfunction (2)

eCADFEM - Installation Setup (29-09-2016) 33

Setting the Timeout of the ANSYSLI

• In the event, eCADFEM does start only after a Reread of the local ANSYSLI-Server,

please check the %ANSYSLIC_DIR%\ansysli_server.log for the following entry:

Unable to connect to FLEXlm path [email protected]; adding to "Unavailable

FLEXlm Servers" cache.

• This message describes, that the Licensing Interconnect temporarily has not achieved a

connection to the eCADFEM Server during the standard interval. And has therefore

deleted it from the license path. Restarting the ANSYSLI-Server will make eCADFEM

availlable again

• To avoid this error, please increase the Timeout with the following, additioal argument in

the file "ansyslmd.ini„:

ANSYSLI_TIMEOUT_FLEXLM=15

The timeout will then be changed from 5 seconds to 15 seconds.