Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Lorem ipsum dolor sit ametLorem ipsum dolor sit ametIntegrated SCADA Solutions to Optimize Utility PV Plant Performance
Eaton SCADA solutions for the solar industry
• Real-time data acquisition and supervisory control
• HMI visualization
• Local and remote alarm management
• User-configurable security model
• Historical data collection and analysis
• Remote user access via web or smartphone
• Comprehensive system diagnostics to simplify troubleshooting
• Open communications interface using industry standard protocol
Proven SCADA Technology. Proven SCADA Solutions.
Providing:
For over 25 years, Wonderware has provided innovative market leading SCADA solutions for the oil and gas, water/wastewater and electric power generation industries. Today, Eaton can provide a comprehensive off-the shelf monitoring and SCADA application built on the field-proven Wonderware System Platform that is specifically designed for utility-scale photovoltaic solar facilities.
This Solar Industry Application is tightly integrated with all of the key components and subsystems typical of any grid-tied solar PV generating plant. It monitors real-time data from inverters, transformers, switchgears, power meters, combiner boxes and weather stations in order to provide key performance indicators that improve operational efficiency and plant reliability.
32 EATON Eaton SCADA solutions for the solar industry EATON Eaton SCADA solutions for the solar industry
54 EATON Eaton SCADA solutions for the solar industry EATON Eaton SCADA solutions for the solar industry
• Preconfiguredsolarapplicationdatabase andgraphicsreduceapplicationengineering
deploymentandtestingeffort
• Intuitive“drill-through”interfacerequires minimaltrainingtobeginusingthesystem
• Keyperformanceindicators(KPIs)help improveOperationsandMaintenance(O&M)
efficiency,whichreducethecostofplantownership
• Predictivesystemanalysismonitorsand comparesDCcurrentsfrominvertersand/orcombinerboxesaswellaspredictedversus actualpowerproductiontowarnofpotential arrayissuesandmaintenanceneeds
• Systemacceptsindustryleadingandstandardcommunicationsinterface(ModbusTCP,DNP3,etc.)
• High-resolutionhistoricaldatastoragefacilitatesdiagnosticanalysisandtroubleshooting
• Powerfulclienttoolsfortrending,data analysisandreporting
• Remotewebaccesstothesystemviathe intranetorVPNconnectionfromanyPC,
Smartphoneortabletdevice
• Remotealarmnotificationandacknowledge- mentviacellorSmartphoneusingemailor
textmessaging
• Built-inredundancyensuresmaximum systemavailability
• Comprehensivesecuritymodelallows personalizedaccessbasedonuserlogin
• Modularandscalabletosupporteasyexpansionwithminimalengineeringeffort
• Supervisorycontroltosupportautomaticpowerfactor,voltageregulationandtrackercontrol
• Standarddaily/weeklyreportsforweatherandpowergenerationallowsearlydetection
anddiagnosisofanypotentialissues
Historical DataCollection and Analysis
Performance KPIsand Reports
Access Controland Security
Field I/O
Alarm and EventManagement
SCADA functions for solar PV systemsCloud Server with
Remote Web Access
Remote Alarm Accessfrom Cell or Smartphone
via Email or Text
Combiner Boxes
Real-Time Graphics
Transformers - Inverters Switchgear Power Meter Weather Stations
Features and benefits of the solar industry application
Standard Graphic DisplaysPlant Overview Graphic Display
Providesahigh-leveloverviewofthesystemwithkeyplantperformanceindicatorsincludingdailypowergeneration,instantaneousgeneration,irradianceandplanarirradiance.Keyinverterinformationisalsodisplayedinordertoaidinmaintenanceandtroubleshootingactivities.Operationscaneasilycompareinverterperformanceandcaneasilyidentifyinverterfaultsataglance.
Inverter Detail Display
Selectingoneoftheinvertersfromtheplantoverviewdisplaycallsupamoredetailedviewoftheinverterdata,allowinguserstomonitorperformanceandoutput,includingfeedandoutputvoltageandcurrents.Faultsspecifictotheinverteraredisplayedinthealarmbanneratthebottomoftheinverterdetaildisplay.
Combiner Box Detail Display
Whenstringlevelmonitoringisimplemented,thecombinerdetailallowsforstringlevelinstantaneousandhistoricaloutputperformanceanalysis.Agraphicalcomparativeanalysisandindividualstringalarmsmakeiteasytoidentifylowstringperformanceordegradationissues.Apull-downmenumakesiteasyfortheusertonavigatetootherinvertersandcombinerboxes.
Trending and Analysis Display
Real-timeandhistoricaldatacanbeanalyzedforanysystemcomponentfromthetrenddisplay.Theusercantrendasmanypointsasdesiredanduseahairlinecursorwithpanandzoomfunctionstofurtheranalyzethedataoveranyuser-definedtimeperiod.
Alarm Historical Summary Display
Thisalarmdisplaysummarizesallhistoricalalarmsandallowstheusertoacknowledgealarmsastheyoccurinreal-time.Theusercanquicklyviewthealarmsoverthelasthour,day,weekormonth.Alarmscanbeacknowledgedfromthisscreenorfromaremotesmartphonesothatfaultscanbeidentifiediftheplantisunattendedbyanoperator.
Power Meter Monitoring Display
Providesaviewofkeypowermetrics,includingenergygenerated,apparentpower,powerfactor,historicalpowergeneration(year-to-date,month-to-date,yesterday).Additionally,allpowerattributescanbetrendedforlong-termanalysis.
76 EATON Eaton SCADA solutions for the solar industry EATON Eaton SCADA solutions for the solar industry
WhileEatonoffersproductsandsolutionstomeetyourmostcriticalelectricalpowermanagementchallenges,wealsohaveoneofthelargestandmostexperiencedteamofpowersystemengineersintheindustry.Eaton’s Electrical Engineering Services and Systems focusesonunderstandingyourbusinessrequirementsandoptimizingyourpowersystem.Wenotonly offerstart-up,acceptancetestingandcommissioningservices,butourengineersandconsultantscanhelpdiagnoseproblems,identifywaystoimproveperformanceortransformconceptsintoflexible,practicalsolutionsthatcanimproveproductivityanduseofcapital.Wecanhelpkeepyoursolarpowersystemsafe,efficient,reliableandup-to-date. EatonprovidesturnkeySCADA solutionsusing wirelesscommunicationstomonitorKPIsfor optimizingsolarpowerperformance.
Eaton is a registered trademark.
All other trademarks are property of their respective owners.
Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.com
© 2014 EatonAll Rights ReservedPrinted in USAPublication No. BR180002EN / ETN-DGOctober 2014