EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

1

EasyIO FS Series Modbus Slave User Guide

Page 2: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

2

Document Change Log

25th

Dec 2019

Document created for FS Series ONLY.

Page 3: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

3

Disclaimer Confidentiality Notice

The information contained in this document is confidential information of EasyIO Holdings Pte Ltd. Such information and the software described herein, is furnished under a license agreement and may be used only in accordance with that agreement. The information contained in this document is provided solely for use by EasyIO Holdings Pte Ltd employees, licensees, and system owners; and, except as permitted under the below copyright notice, is not to be released to, or reproduced for, anyone else. While every effort has been made to assure the accuracy of this document, EasyIO Holdings Pte Ltd is not responsible for damages of any kind, including without limitation consequential damages, arising from the application of the information contained herein. Information and specifications published here are current as of the date of this publication and are subject to change without notice. The latest product specifications can be found by contacting our corporate headquarters or support channel. Trademark Notice EasyIO logo are registered trademarks of EasyIO Holdings Pte Ltd. CPT Tool is by Online Tools Inc. BACnet and ASHRAE are registered trademarks of American Society of Heating, Refrigerating and Air- Conditioning Engineers. All other product names and services, mentioned in this publication, that are known to be trademarks, registered trademarks, or service marks are the property of their respective owners. Copyright and Patent Notice This document may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form without prior written consent from EasyIO Holdings Pte Ltd Copyright © 2019 EasyIO Holdings Pte Ltd. All rights reserved

Disclaimer

The material in this manual is for information purposes only. The contents and the product it describes are subject to change without notice. EasyIO Holdings Pte Ltd makes no representations or warranties with respect to this manual. In no event shall EasyIO Holdings Pte Ltd be liable for any damages, direct or incidental, arising out of or related to the use of this manual.

EasyIO Holdings Pte Ltd 101, Cecil Street #09-07 Tong Eng Building Singapore 069533 Worldwide and Asia Pacific Support : [email protected] Americas Support : [email protected] Europe Support : [email protected]

Page 4: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

4

Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15

of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a

residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not

installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does

cause harmful interference to radio or television reception, which can be determined by turning the equipment off

and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void

the user's authority to operate this equipment.

FCC Caution

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This

device may not cause harmful interference, and (2) this device must accept any interference received, including

interference that may cause undesired operation.

FCC Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This

equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

RF Exposure: A distance of 20 cm shall be maintained between the antenna and users, and the transmitter module

may not be co-located with any other transmitter or antenna.

Page 5: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

5

Table of Contents Introduction ................................................................................................................................................................... 6

Prerequisites .................................................................................................................................................................. 6

Device Software Configuration Limitations FG+ and FS ................................................................................................ 6

Configuring the Modbus Serial Network ....................................................................................................................... 7

Configuring the Modbus TCP Slave Network ............................................................................................................... 11

Technical Support ........................................................................................................................................................ 14

Page 6: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

6

Introduction EasyIO FG Series and FS Series supports Modbus device using the Modbus Slave driver. It is capable of handling the following Modbus slave protocols;

1. Modbus RTU Slave 2. Modbus TCP Slave

Prerequisites 1. CPT Tool dated 10th Oct 2018 or later. Latest CPT at the time of the document is 06th Dec 2019. 2. For FS Series running v3.0b51b or later firmware is the best.

Device Software Configuration Limitations FG+ and FS Modbus RTU Slave/ Modbus TCP Slave

Max Network allowed 1 (of both drivers)

Max Discrete Point allowed 200 register address (total)

Max Coil Output allowed 200 register address(total)

Max Input Register allowed 200 register address, depending to data type. Integer data type occupy 1 register address Float data type occupy 2 register address Long data type occupy 2 register address

Max Holding Register allowed 200 register address, depending to data type. Integer data type occupy 1 register address Float data type occupy 2 registers address Long data type occupy 2 registers address

The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register addressing limitations which need to be observed when both network drivers are used on the same device. For example, the coil address space in the FS series is shared by both the RTU and TCP networks. If a coil address is used in the RTU network the same address cannot be used in the TCP network. For example if an RTU network is created and uses the a coil address “0”, the TCP network cannot create a new coil address “0” however it can “share” the value from the RTU network coil address and vice versa. If a new individual coil address is required to be created the network (RTU or TCP) should employ the next available consecutive unused DEVICE coil address irrespective of network type.

Page 7: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

7

Configuring the Modbus Serial Network The architecture of the driver is deployed as shown below in Step 2. The network object can be dropped anywhere in the Sedona app tree. Our recommendation is to create a separate folder for each network, identified as you require. Network

Points **Note** In order to configure the Modbus driver, below kits needs to be installed (minimum requirement).

1. easyioFGMbSlave – 1.0.45.51.16 or higher 2. easyioFGDriver - 1.0.45.51.3 or higher 3. easyioFGSerial – 1.0.45.51.2 or higher

Step 1 Connect to the controller with CPT Tools.

Default login credentials are as below;

IP address : 192.168.10.12 Username : admin Password :<no password> Add the kits to the controller by navigating to manage kits and install easyioFGMbSlave and easyioFGDriver into

your controller.

Step 2 Double click the service folder. It will display the service folder objects. If the SerialService object is not present in the folder, drag and drop the service object in to the service folder from the easyioFGSerial kit library.

Page 8: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

8

Step 3 Choose easyioFGMbSlave from Sedona Palette Drag & drop the ModbusSlaveSerialNetwork into your App. The object can be dropped in the EasyIO folder or a new folder can be created for the Serial Network Object. In the example below, the object is dropped into a new folder named “Modbus”.

Step 4 Double click the object to access the property sheet. Configuration of the RTU network parameters such as baud rate, parity etc is carried out here. The device address on the serial networkis set in this property. When complete and all serial network and operational parameters are entered correctly and complete enable the network. Please ensure the “D2” terminal set is used for the serial network connection and observe the correct polarity.

Step 5 Drop any Modbus “serial” register type object under the Network Object. Note that the register object must be a child of (dropped below) the Network object. It is possible to create folders below the Network Object to allow logical management of the register objects.

Page 9: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

9

Step 6 Modbus registers supported is DECIMAL format register addresses. HEX or Modbus addressing formats are not allowed and will not operate. Step 7 By default all registers are set to the disabled mode Enable = false). You will need to enable each register object in the application in order for the register to be discovered by other systems i.e. the Modbus Master.

Step 8 A maximum of 200 Input Register and Holding Register are available. The FG Series Modbus Serial Slave Network supports 3 data types including the Integer, Float and Long data types. Integer and Signed Integer uses 16bit data and is represented with 1 register address. Float and Long occupy 32bit data and is represented with 2 register addresses. See below example of setting the address.

Input/ Holding Registers Data Type

Precision Remarks

Word 16 bit 16 bit Signed Integer Standard

Long 32 bit 32 Bit Signed Integer Standard

Float 32 bit 32 Bit Float Standard

Page 10: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

10

Address Name Register Type

------- -------------------- --------------

1000 Set Point (Float type) floating point (2 registers)

1002 Duration (Long type) 32-bit data (2 registers)

1004 Count (Integer) 16-bit data (1 register)

1005 Delay (Signed Integer) 16-bit data (1 register)

Step 9

The Modbus register by itself does not export any value. You will need to manually link a valid value to the Modbus register. Below an example of exporting a temp value as Modbus register.

Page 11: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

11

Configuring the Modbus TCP Slave Network The architecture of the driver is deployed as below. The network object can be located anywhere in the Sedona app tree. Our recommendation is to create a separate folder foreach network. Network

Points **Note** In order to configure the Modbus Slave driver, below kits needs to be installed (minimum requirement).

1. easyioFGMbSlave – 1.0.45.51.16 or higher 2. easyioFGDriver - 1.0.45.51.3 or higher 3. easyioFGSerial – 1.0.45.51.2 or higher

Step 1 Connect to the controller with CPT Tool.

Default login credentials are as below;

IP address : 192.168.10.12 Username : admin Password :<no password> Add the kits to the controller by navigating to manage kits and install easyioFGMbSlave and easyioFGDriver into

your controller.

Step 2 Choose easyioFGMbSlave from Sedona Palette Drag & drop the ModbusSlaveTCPNetwork into your App. The object can be anywhere in the EasyIO folder. The object can be placed in a new folder as well. In this case, the object is drop into a new folder named “Modbus”.

Page 12: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

12

Step 3 Double click the object to get into the property sheet. Enable the network.

Step 4 Drop any Modbus register type object under the Network Object. Register object must be a child of the Network object. However folders in the Network object is possible for better data management.

Input/ Holding Registers Data Type

Precision Remarks

Word 16 bit 16 bit Signed Integer Standard

Long 32 bit 32 Bit Signed Integer Standard

Float 32 bit 32 Bit Float Standard

Page 13: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

13

Step 5 Modbus registers supported is DECIMAL format register addresses. HEX or Modbus addressing formats are not allowed and will not operate. Step 6

By default all register are disable. You will need to enable it in order for the register to be discovered by other system.

Step 7 Input Register and Holding Register comes with max 200 address. It support 3 data types Integer, Float and also Long. Integer and Signed Integer uses 16bit data and is represented with 1 register address. Float and Long occupy 32bit data and is represented with 2 register addresses. See below example of setting the address. Address Name Register Type

------- -------------------- --------------

1000 Set Point (Float type) floating point (2 registers)

1002 Duration (Long type) 32-bit data (2 registers)

1004 Count (Integer) 16-bit data (1 register)

1005 Delay (Signed Integer) 16-bit data (1 register)

Step 8 The Modbus register by itself does not export any value. You will need to manually link a valid value to the Modbus register. Below an example of exporting a temp value as Modbus register.

Page 14: EasyIO FS Series Modbus Slave User Guide€¦ · The FS series is capable of employing both Modbus Slave RTU and Modbus Slave TCP networks on the same device. There is however register

FG Series Modbus Slave v1.0

14

Technical Support

For technical issue, please contact respective region support channel. Worldwide and Asia Pacific Support : [email protected] Americas Support : [email protected] Europe Support : [email protected]