16
easy&cosy digital thermostat Installation guide EN

easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

easy&cosy digital thermostatInstallation guide EN

Page 2: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

2 VIIOI102

Table of content

Introduction 3

Button and display description 4

Installing and wiring the thermostat 5

Basic functionality - Select how to control your floorheatingsystem 6 -Recommendedsettings 7 -Settingtheclock 8 -Settingthemaximumfloortemperature8 -Readingthefloortemperature 9 -Frostprotectionmode 9

Timer functionality -ActivateTimerMode 10 -Programmingthetimer 10 Technical specifications 14

Home Heating Warranty 15

EN

Page 3: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

VIIOI102 3

ENIntroduction

Easy&cosydigitalcontrollerisanadvanceddigitaltimerthermostat,whichallowsyoutocontrolyourfloorheatingsystembyeitherthefloortemperature,theroomtemperatureorcombined.

Pleasefollowtheinstructionsinthismanualtoensuremanyyearsoftroublefreeusage.

CongratulationswithyournewHomeHeatingfloorheatingsystem.

!Please notice that the thermostat must be installed by an authorized electrician

Page 4: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

4 VIIOI102

Buttonanddisplaydescription

Currentroomtemperature

Heatingelementwarming

Weekday

Thermostaton

On/off

Down

Up

Clock

Mode

Currentfloortemperature

EN

Timermodeactivated

Frostprotectionmodeactivated

FT

Page 5: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

VIIOI102 5

Installingandwiringthethermostat

Tomountthethermostattothewallbox/wallsocket,firstopenthethermostatbygentlypushingthetabsinthebuttomofthethermo-stat.Tofixthethermostat,screwinproperlysizedscrewsintothewallsocket/wallbox.Whenproberlyfastendandcablesconnected(seediagrambelow),mountthefrontpaneltothebackpartagain.

Electricalwallbox/socket

Wiring diagram

Remotesensor

Mod

el:

easy

&co

sy

dig

ital

con

trol

ler

Mai

ns v

olta

ge:

85-

240V

~

raIP

tin

g:

IP30

S1

L Lo

adS2

LN

Lo

adN

13A

Max

. lo

ad:

Tem

pera

ture

:

0T30

85-240V~

Max13A

EN

Page 6: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

6 VIIOI102

Basic functionality

POWER ON/OFF Toturnthermostatonoroffpress“ ”

SELECT HOW TO CONTROL YOUR FLOOR HEATING SYSTEMYourHomeHeatingfloorheatingsystemcanbecontrolledeitherbythe:

• Floor temperature - program mode 2 Theheatingelementturnson/offaroundafloortemperaturesetpoint(thetemperatureshowninthedisplayistheactualfloortemperature)

• Room temperature - program modes 1 & 4 Theheatingelementturnson/offaroundaroomtemperaturesetpoint(thetemperatureshowninthedisplayistheactualroomtemperature)

• Combined floor and room temperature - program modes 3 & 5 Theheatingelementturnson/offaroundaroomtempera-turesetpointwitharequestedmax.floortemperature(floortemperatureisprioritizedoverroomtemperature)

Change between the above floor heating modes:Withthethermostatturnedoff.Press“ ”and“ ”for6secondsSelectmode1to5(seetableonnextpage)

Afterchoosingthedesiredmodedonotpressanyfurtherbuttonsandthethermostatwillgobacktonormalstandbymode.

EN

Page 7: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

VIIOI102 7

Basic functionality

RECOMMENDED SETTINGSHomeHeatingrecommendsthefollowingsettingsfordifferenttypeoffloorconstructions:

Topflooring

Programmode

Wooden

floor*

Tiled

floor**

1 (roomsensor)

Iftotaleffect:0W-1840Wx

2 (floorsensor)

Iftotaleffect:0W-2990W x x

3(combinedfloorandroomsensor)Iftotaleffect:1840W-2990W

x x4

(roomsensor)Iftotaleffect:1840W-2990W

x5

(combinedfloorandroomsensor)Iftotaleffect0W-1840W

x x

*Topflooringmadeof parquet, laminate,massivewood, carpet,linoliumorthelike.

**Topflooringoftiles,concrete,marbleorthelike.

EN

Page 8: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

8 VIIOI102

Basic functionality

SETTING THE CLOCKWiththethermostatturnedon.

Press“ ”once,hourwillbeflash.UsetheUp/Downkeytoselectthehours.Press“ ”again,minutewillbeflash.UsetheUp/Downkeytoselecttheminutes.Press“ ”buttonagain,tilltheweekdayflashes.UsetheUp/Downkeytoselectthedayoftheweek.

After settingweekdaydonotpressany furtherbuttonsand thethermostatwillgobacktonormaloperatingmodemode.

SETTING THE FLOOR TEMPERATURE MAX. LIMITThisfunctionisusedforwoodenfloorsmainlyandisonlyavailableinprogrammodesusingthefloorsensor(programmode3and5)Thetemperaturesettingshouldbemaximum35C,whichisalsothedefaultsetpointofthethermostat.Ifyouchoose to control thefloor temperaturesolelyby thefloorsensor(programmode2)themax.floortemperatureissetfor35Candcan‘tbechanged.

Change the floor temperature max. limit (program mode 3 and 5)Withthethermostatturnedoff.Holdthe“M”buttonfor10secondsuntilthedisplayshows“ ”.Nowletgoofthebutton“M”andthedisplaywillshow“SET”.Youarenowpromptedtoenterthemaximumfloortemperature(temperaturerange20°C-45°C)

EN

Page 9: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

VIIOI102 9

Basic functionality

READING THE FLOOR TEMPERATURE (only in program mode 3 and 5)

Withthethermostatturnedon.Press“M”once,the“FT ”willbeflashed,andthedisplaywillshowthefloortemperature.

Inprogrammode2(floorsensor)thedisplayalwaysshowsthecurrentfloortemperature.

Inprogrammode1and4(roomsensor)thedisplayalwaysshowsthecurrentroomtemperature.

FROST PROTECTION MODEToenablefrostprotectionmode.

Withthermostatturnedoff.Press“M”for3seconds.Select01(00=disabled)

Whenenabledandthermostathasbeenturnedoff,theheatingwillbeactivatediftheroom/floortemperatureislowerthan5°C;theheatingwillbestoppediftheroom/floortemperatureishigherthan7°C.

Whenfrostprotectionmodehasbeenenabledthedisplaywillshow“ ”.

EN

Page 10: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

10 VIIOI102

ACTIVATE TIMER MODE Whenusingthetimermode,youmustfirstactivatethetimermode:

Withthethermostatturnedon,holdthe“M”buttonfor3seconds.Youcanselectbelowsettings:

00=Override(disabletimerfunctionality)01=Programmable.Andthedisplaywillshow“ ”.

Leavethethermostatanditwillgobacktonormaldisplaying.

PROGRAMMING THE TIMER - Mode 01WhenprogrammingyouneedtoselectProgrammablefunctionandthedisplaymustshow“ ”(seeabove)

Youcannowsettheheatingprograms.Thethermostatmusthave4heatingperiodsfortheweekdaysand4heatingperiodsfortheweekend.

Pleasenotice that theprogrammingof thewhole calendarweekmust take place in one continuous process,soit isagoodideatohave theperiodswrittendown for referencewhenprogrammingthethermostat.

Note, for the weekend you will also need to program 2 periods. You can choose one of the periods to be very short or in extension of the other.

Timer functionalityEN

Page 11: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

VIIOI102 11

Example, weekdays:Period1startingat07.00-Temperaturesetting22CPeriod2startingat08.30-Temperaturesetting18CPeriod3staringat17.00-Temperaturesetting22CPeriod4startingat23.00-Temperaturesetting18C

Example, weekend:Period1staringat09.00-Temperaturesetting22CPeriod2staringat23.00-Temperaturesetting18CPeriod3staringat23.01-Temperaturesetting22CPeriod4staringat23.02-Temperaturesetting18C

My settings:

Week days:

Period1on °C

Period2on °C

Period3on °C

Period4on °C

Weekend:

Period1on °C

Period2on °C

Period3on °C

Period4on °C

Timer functionality EN

Page 12: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

12 VIIOI102

How to progamme the timer:Holdthe“ ”for3seconds,thenumber1and“MoTuWeThFr”aredisplayed.

Thisindicatesthatyoucanprogramthefirstswitchingtimefortheweek-day.

UseUp/Downkeytosettherequiredstarttime.Press“ ”toacceptthissetting.UsetheUp/Downkeytosettherequiredtemp.Press“ ”toacceptthissetting.Repeatforswitchingtimes2-4week-day.

Afteryouhaveprogrammedtimes1-4fortheweekday,youarenowabletosettheswitchingtimesforweekend“SaSu”willbedisplayed.

UseUp/Downkeytosettherequiredstarttime.Press“ ”toacceptthissetting.UsetheUp/Downkeytosettherequiredtemp.Repeatforswitchingtimes2-4fortheweekend.

Todisablethetimer,select“Override”(Mode01)

How to override settings in TIMER MODEAtanytimeyoucanchangethepresettimertemperaturesettingsbypressingtheUp/Downkey.Yourmanualoverridewillapplyuntilthestartofthenexttimercycle.Thereafterthethermostatwillresumeyourprogrammedsettings.

Timer functionalityEN

Page 13: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

VIIOI102 13

ENNotes

Page 14: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

14 VIIOI102

Technical specifications

Externalsensor: NTC10kOhmat25°C

Sensorvalues:15°C18°C20°C22°C

14,8kOhm13,1kOhm12,1kOhm11,2kOhm

Display: LCD

Powerconsumption: <2W

Set-pointrange: Room:5°C to 35°C

Floor:20°C to 35/45°C

Accuracy: ±1°C

Buttons: Touchpad

Switchcurrentrating: <13A(resistiveload)

Mainsvoltage: 85-240V~

Dimensions: 86x86x13mm(WxHxD)

Fixingscrewwidth: 60mm

Housing: ABS+PCFlameRetardent

Operatingrating: 0~30°C,5~95%RH(non-con-

densing)

EN

Page 15: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

VIIOI102 15

Home Heating warranty

Warranty certificate

Electrician/installer:

Thermostatname:

Installationdate:

Articlenumber:

Stamp:

Stamp:

Please notice!InordertoobtaintheHomeHeatingwarrantyanauthorizedelec-

trician/installermustfillinthebelowfields.

Name:

Telephone:

Address:

Zipcode/City:

EN

Page 16: easy&cosy digital thermostathh-homeheating.dk/media/1092/hh-digital-controller-en.pdf · which allows you to control your floorheating system by either the floor temperature, the

2015/06EN

Home HeatingUlvehavevej 617100 Vejle Denmark

E-mail: [email protected]