www. cobon.co.kr ISO9001 : 2008 ISO14001 : 2004 TUV compliant RoHs EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE Cobontech Co., Ltd.

EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

www.cobon.co.krISO9001 : 2008

ISO14001 : 2004TUV compliant

RoHs

EARTH LEAKAGE DETECTION MODULECURRENT SENSOR MODULE

Cobontech Co., Ltd.

Page 2: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

The Cobontech Co., Ltd. is specialized in the fields of earth leakage detection module and current sensor module since its establishment. We use our skill to develop customized solutions and products. We stand for superior quality and reliable technology in Korean market and lead the market for earth leakage detection module selling more than 10 million modules per a year. Our products can be used mainly in earth leakage circuit breaker, electronic toilet seat (Bidet), electric vehicle charging system, solar energy, electric water heater and various electric devices. We can deal with every conceivable application area to prevent electric shock and fire thanks to our high technical skills and know-how. Our products are modular type and provide benefits lowering development time and costs for customers. The modules developed in slim and small size can used in limited space of customer’s product. Our researchers at laboratory always engage in close and partnership based interaction with our customers in order to realize customer demands and requirements in the best possible manner.

COBONTECH is a company specialized in earth-leakage detection modules.

Always grappling to develop more integrated and sensitive, much smaller, broader functioned solutions.

CUSTOMERS

02 l Cobontech Co., Ltd.

APPLICATION

Earth leakage circuit breaker (ELCB, RCD)

Electronic cleansing toilet seat

Electric Induction EV charging station High-speed railway

Solar Energy Panel

Electric water heater

Page 3: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

www.cobon.co.kr l 03

EARTH LEAKAGE DETECTION MODULECURRENT SENSOR MODULE

Page 4: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

04 l Cobontech Co., Ltd.

●●● B or B+ Current Sensor Module

B or B+ Current Sensor Module of RCCB, RCBO, ELCB

•Nominal current measurement: from ± 0.01A DC, AC •Excellent linearity: 15 ppm •High resolution •Very low offset drift •Overall accuracy at IPN @ +25°C: ≤±0.1 % •Wide frequency bandwidth up to 100 kHz (- 3 dB) •RoHS Compliant

Main characteristics

•DC, AC pulse currents' measurements with galvanic isolation •Nano Crystal Fluxgate technology •Electrostatic shield between primary and secondary circuit •Bipolar Power supply ±15 Volt •Operating temperature range from -20 to +85°C •Wire Connector Type•Current output

Feature

Rated residual current (IΔn) 30, 100, 300, 500 mA

Operating time (ms) Instantaneous, Short time delayed, Selective

Peak withstand current Surge Current Proof 3KA (8/20 µs)

Standard IEC / EN 61009-1, IEC / EN 62423

Technical Data

SELF Exiter & Fluxgate Detector

FluxgateController

Saturation Detector

B-TYPE RCCB Module(CF0.1AD(05~35))

Page 5: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

●●● Earth Leakage Detection Module

A-COB detects AC and Half-wave, ±6mA DC leakage current.

DETECTING CURRENT WAVEFORM

AC

Pulse

DC + AC

•A type Earth leakage circuit breaker •Electric Vehicle Charging Station•Phase control industrial equipment

APPLICATIONCHARACTERISTICS SYMBOL

VALUEUNIT

MIN TYP MAX

Supply Voltage Vs 12 16 20 V

Operating Current IΔn 18 22 28 mA

Operating Time Ot 30 mS

Supply Current Is 0.3 mA

Power Dissipation Pd 1 3 6 mW

Operating Junction Temperature Tj -30 ~ +85 ℃

Storage Temperature Tstg -45 ~ +90 ℃

APPLICATION

MODEL Working Voltage

Trip OperatingApplication

CircuitTrip Current [mA] Time [mS]SPEC MIN TYP MAX

A-COB 15 100~240 Vac

30 18 22 28 30 FIG1

RATINGS & MODELS

DETECTING CURRENT

A-TYPE RCCB Module (A-COB)

Over-current Detector Module for RCCB (I-COB)

INSTANTANEOUS OPERATION CURRENT TABLE

OPERATING TIME

RATED CURRENTB-TYPE C-TYPE D-TYPE

250% ~ 500% 500% ~ 100% 1000% ~ 2000%

16AF 40 ~ 80 A 80~ 160 A 160 ~ 320 A

20AF 50 ~ 100 A 100 ~ 200 A 200 ~ 400 A

32AF 80 ~ 160 A 160 ~ 320 A 320 ~ 640 A

TYPE ≤ 250% ≤ 500% ≤ 1000% ≤ 2000%

B ≥ 0.1 ≤ 0.1 ≤ 0.1 ≤ 0.1

C ≥ 0.1 ≥ 0.1 ≤ 0.1 ≤ 0.1

D ≥ 0.1 ≥ 0.1 ≥ 0.1 ≤ 0.1

Instantaneous COB is operated instantaneously by an amount(%) of overload of circuit breaker.

www.cobon.co.kr l 05

Page 6: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

06 l Cobontech Co., Ltd.

CHARACTERISTICS SYMBOLVALUE

UNITMIN TYP MAX

Supply Voltage Ve 14.7 25 Vac

Operating Time To 100 mS

Supply Current Is 2 mA

Power Dissipation Pd 150 250 350 mW

Operating Junction Temperature Tj -35 ~ +80 ℃

Storage Temperature Tstg -45 ~ +90 ℃

ABSOLUTE RATINGS / RELIABILITY ITEMS

Open-Phase Detector COB (PO-COB)

The open-phase detector COB (PO-COB) is a product to be operated if it is open-phasing does not work and to verify the safe connection of the power supply.

•Low Power Consumption (Pd=5mW, 220V)•Input High Frequency Noise Filter•Internal Blanking Circuit•High Gain Differential Amplifier•Minimum 100㎂ Output Current to Trigger SCR•Extremely Minimized External Part Counts•Built-in thyristor (MCR100-8)•High noise immunity, Large surge margin•5P HIC package by FR4

●●● Earth Leakage Detection Module

CHARACTERISTICS SYMBOLVALUE

UNITMIN TYP MAX

Supply Voltage Ve 12 20 Vac

Trip Voltage Vt 12 13.5 15 mV

Operating Time To 30 mS

Supply Current Is 2 mA

Power Dissipation Pd 150 250 350 mW

Operating Junction Temperature Tj -35 ~ +80 ℃

Storage Temperature Tstg -45 ~ +90 ℃

ABSOLUTE RATINGS / RELIABILITY ITEMS

MODEL Working Voltage

Trip OperatingApplication

CircuitTrip Current [mA] Time [mS]SPEC MIN TYP MAX

Ior-COB 220VacIor 30 22 25

28 30Ioc 90 70 75

RATINGS & MODELS

C Earth Leakage Detector COB (Ior-COB)

C earth leakage detector COB (Ior-COB) prevents an earth leakage breaking module from operating through the capacitive leakage current (Ioc).

•Low Power Consumption (Pd=5mW, 220V)•Input High Frequency Noise Filter•Internal Blanking Circuit•High Gain Differential Amplifier•Minimum 100㎂ Output Current to Trigger SCR•Extremely Minimized External Part Counts•Built-in thyristor (MCR100-8)•High noise immunity, Large surge margin•5P HIC package by FR4

Resistive leakage current [Ior] : Leakage current that flows because of an earth faultCapacitive leakage current [Ioc] : Leakage current that flows at all times through self-capacity without an earth faultCombined leakage current [Io] : Ior+ Ioc combined currentAs the existing earth leakage breaker is operated by the (Io) value of a composite leakage current, the breaker is often automatically cut off because of the Ioc that flows through the LED lamp, computer power, inverter, etc.There is no automatic trip in an C earth leakage detector COB (Ior-COB) as it has been designed to not operate in less than three times the Ioc current.Operating current of C earth leakage detector COB (Ior-COB) : Ior = 25mA  /  Ioc = 3 X Ior = 75mA

Page 7: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

www.cobon.co.kr l 07

●●● Earth Leakage Detection Module

CHARACTERISTICS SYMBOLVALUE

UNITMIN TYP MAX

Supply Voltage Ve 12 20 Vac

Trip Voltage Vt 12 13.5 15 mV

Operating Time To 30 mS

Supply Current Is 2 mA

Power Dissipation Pd 150 250 350 mW

Operating Junction Temperature Tj -35 ~ +80 ℃

Storage Temperature Tstg -45 ~ +90 ℃

ABSOLUTE RATINGS / RELIABILITY ITEMS

MODEL Working Voltage

Trip OperatingApplication

CircuitTrip Current [mA] Time [mS]SPEC MIN TYP MAX

NS-COB15220Vac

15 9 11 1330 FIG1

NS-COB30 30 20 23 26

RATINGS & MODELS

Single Phase COB (NS-COB)

Single-phase COB (NS-COB) is a product specialized for a single-phase earth leakage breaker (residential).

•Low Power Consumption (Pd=5mW, 220V)•Input High Frequency Noise Filter•Internal Blanking Circuit•High Gain Differential Amplifier•Minimum 100㎂ Output Current to Trigger SCR•Extremely Minimized External Part Counts•Built-in thyristor (MCR100-8)•High noise immunity, Large surge margin•5P HIC package by CEM-1

CHARACTERISTICS SYMBOLVALUE

UNITMIN TYP MAX

Supply Voltage Ve 12 20 Vac

Trip Voltage Vt 12 13.5 15 mV

Operating Time To 30 mS

Supply Current Is 2 mA

Power Dissipation Pd 150 250 350 mW

Operating Junction Temperature Tj -35 ~ +80 ℃

Storage Temperature Tstg -45 ~ +90 ℃

ABSOLUTE RATINGS / RELIABILITY ITEMS

MODEL Working Voltage

Trip OperatingApplication

CircuitTrip Current [mA] Time [mS]SPEC MIN TYP MAX

MFS-COB 30220 ~

460Vac

30 20 23 2630 FIG1MFS-COB 100 100 60 75 90

MFS-COB 300 300 180 225 270

RATINGS & MODELS

Three-Phase COB (MFS-COB)

Three-Phase COB (MFS-COB) is a product specialized for three-phase earth leakage breaker (industrial).

•Low Power Consumption (Pd=5mW, 220V)•Input High Frequency Noise Filter•Internal Blanking Circuit•High Gain Differential Amplifier•Minimum 100㎂ Output Current to Trigger SCR•Extremely Minimized External Part Counts•Built-in thyristor (MCR100-8)•High noise immunity, Large surge margin•5P HIC package by CEM-1

Page 8: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

08 l Cobontech Co., Ltd.

●●● Earth Leakage Detection Module

CHARACTERISTICS SYMBOLVALUE

UNITMIN TYP MAX

Supply Voltage Ve 12 20 Vac

Trip Voltage Vt 12 13.5 15 mV

Operating Time To 100 mS

Supply Current Is 2 mA

Power Dissipation Pd 150 250 350 mW

Operating Junction Temperature Tj -35 ~ +80 ℃

Storage Temperature Tstg -45 ~ +90 ℃

ABSOLUTE RATINGS / RELIABILITY ITEMS

MODEL Working Voltage

Trip OperatingApplication

CircuitTrip Current [mA] Time [mS]SPEC MIN TYP MAX

Overvoltage 220V 300 280 300 320 > 1 FIG1

RATINGS & MODELS

Overvoltage Breaking COB (OV-COB)

The overvoltage breaking COB (OV-COB) is a product to automatically cut off the power supply in case the applied voltage is more than 300V.

•Low Power Consumption (Pd=5mW, 220V)•Internal Blanking Circuit•Minimum 100㎂ Output Current to Trigger SCR•Extremely Minimized External Part Counts•Built-in thyristor (MCR100-8)•High noise immunity, Large surge margin•5P HIC package by FR4

Classification Delaying time Remarks

The maximum breaking time 1.0 sec Variable

The minimum off time 0.03 sec Variable

CHARACTERISTICS SYMBOLVALUE

UNITMIN TYP MAX

Supply Voltage Ve 12 20 Vac

Trip Voltage Vt 12 13.5 15 mV

Operating Time To 2 mS

Supply Current Is 150 250 350 mA

Power Dissipation Pd 150 250 350 mW

Operating Junction Temperature Tj -35 ~ +80 ℃

Storage Temperature Tstg -45 ~ +90 ℃

ABSOLUTE RATINGS / RELIABILITY ITEMS

RATINGS & MODELS

Delay COB

Delay COB is used to protect a system when installing a quick breaker and an SPD.

•Low Power Consumption (Pd=5mW, 220V)•Input High Frequency Noise Filter•Internal Blanking Circuit•High Gain Differential Amplifier•Minimum 100㎂ Output Current to Trigger SCR•Extremely Minimized External Part Counts•Built-in thyristor (MCR100-8)•High noise immunity, Large surge margin•5P HIC package by FR4

Page 9: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

www.cobon.co.kr l 09

●●● Earth Leakage Detection Module

RING-COB (RC6PN)

Integrated earth leakage breaking module (integration of HIC, ZCT, and manual component)Patent registration : integrated earth leakage breaking device and its manufacturing method (Patent No. 10-0549396)

•Low Power Consumption•Input EMC improved Noise Filter•Input Rectifier Circuit•Internal Blanking Circuit•High Gain Differential Amplifier•Minimum 100㎂ Output Current to Trigger SCR•Extremely Minimized External Part Counts•High noise immunity, Large surge margin

A bidet module is a sensor-integrated earth leakage detection module to block moisture with urethane molding by converging the core component for earth leakage detection and the coil sensor part. This guarantees safety by being mainly applied to bidets. It is recommended to be applied to streetlights, coastal areas with high salinity, etc.

CASE MOLDING

Flame Retardant – Polypropylene POLYURETHANE EPOXY A/B NABAKEM

CHARACTERISTICS SYMBOLVALUE

UNITMIN TYP MAX

Supply Voltage Vac -90% AC INPUT 110% Vac

Trip Voltage IΔn 7.5 11.5 15 mV

Operating Time Ot 30 mS

Supply Current Is 2 mA

Power Dissipation Pd 800 mW

Operating Junction Temperature Tj -35 ~ +80 ℃

Storage Temperature Tstg -45 ~ +90 ℃

ABSOLUTE RATINGS / RELIABILITY ITEMS

CASE & MOLDING

12±0.2

3.9±0.2

7.1±0.2

18±

0.2

11.4±0.2 8±2

8±2Ø6±0.2R9±0.2

1.5±0.5

1.5±

0.5

0.8±

0.1

1.9±

0.2

5.6±

0.2

3±0.

2

Page 10: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

10 l Cobontech Co., Ltd.

RCCB TESTER (COBON-1701)

Output current

Classification Specification

Voltage AC110V, AC220V, AC380V, AC460V, AC480V

Range 80%, 85%, 100%, 110%

Output voltage

Classification Specification

DISPLAY type FND type

DISPLAY TIME, R-LOAD current, C-LOAD current

DISPLAY

RCCB TESTER (COBON-1901)

Classification Specification

System Constant-current system

Type R-LOAD current, C-LOAD current, R-LOAD + C-LOAD current

Phase angle 0°, 180°

Range0.5A 0.002A ~ 0.5A

5A 0.02A ~ 5A

Frequency 50Hz, 60Hz

Classification Specification

System Constant-current system

Type R-LOAD current,C-LOAD current,R-LOAD + C-LOAD current

Phase angle 0°, 180°

Range0.1A 0.002A ~ 0.1A

1A 0.02A ~ 1A

Frequency 50Hz, 60Hz

Output current

Classification Specification

Voltage AC110V, AC220V, AC380V, AC460V, AC480V

Range 80%, 85%, 100%, 110%

Output voltage

Classification Specification

DISPLAY type FND type

DISPLAY TIME, R-LOAD current, C-LOAD current

DISPLAY

Power supply input : AC220V/60Hz

Power supply input : AC220V/60Hz

Page 11: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

www.cobon.co.kr l 11

CF01AD (05~35)

Nominal primary current (IPN) 1.0A A r.m.s.

Measuring range @ ±15V (±5%) 2.0A A peak

Max. measuring resistance @ IP max & ±15V (±5%) 4450 Ω

Min. measuring resistance @ IPN & ±15V (±5%) 1000 Ω

Turn number 500 Turn

Secondary current at IPN 1/500 A

Accuracy at IPN @ +25°C ≤±0.1 %

Offset current @ +25°C ≤±100 uA

Linearity ≤±0.05 %

Bandwidth @ -3dB ≤100 kHz

Max. no-load consumption current @ ±15V (±5%) ≤20 mA

Secondary resistance @ +85°C ≤30 Ω

Dielectric strength Primary/Secondary @ 50Hz, 1min 3 kV

Supply voltage @ ±20% ±15V V dc

Mass 0.019 kg

Operating temperature -20 ~ +85 °C

Storage temperature -25 ~ +125 °C

●●● Current Sensor Module

•Nominal current measurement: from 0.1A DC, AC •Excellent linearity: 15 ppm •High resolution •Very low offset drift •Overall accuracy at IPN @ +25°C: ≤±0.1 % •Wide frequency bandwidth up to 100 kHz (- 3 dB) •RoHS Compliant

Main characteristics

•DC, AC pulse currents' measurements with galvanic isolation •Nano Crystal Fluxgate technology •Electrostatic shield between primary and secondary circuit •Bipolar Power supply ±15 Volt •Operating temperature range from -20 to +85°C •Wire Connector Type•Current output •Really quick response time (<100 ns)

Features

•�Typical applications: ELCB, RCB, ACB, Photovoltaics, Electric Vehicle, Rapid Transit Railway•�Feedback element in precision current regulated devices (power supplies…)•�Precise and high stability inverters•�Medical equipment•�Energy measurement•�Power analyzers

Standard compliance

•Current overload capability •Additional output indicating the transducer state

Remarks

Page 12: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

12 l Cobontech Co., Ltd.

CF10AD (05~35)

Nominal primary current (IPN) 10A A r.m.s.

Measuring range @ ±15V (±5%) 20A A peak

Max. measuring resistance @ IP max & ±15V (±5%) 445 Ω

Min. measuring resistance @ IPN & ±15V (±5%) 10 Ω

Turn number 1000 Turn

Secondary current at IPN 1/1000 A

Accuracy at IPN @ +25°C ≤±0.1 %

Offset current @ +25°C ≤±100 uA

Linearity ≤±0.05 %

Bandwidth @ -3dB ≤100 kHz

Max. no-load consumption current @ ±15V (±5%) ≤20 mA

Secondary resistance @ +85°C ≤150 Ω

Dielectric strength Primary/Secondary @ 50Hz, 1min 3 kV

Supply voltage @ ±20% ±15V V dc

Voltage drop ≤3 V

Mass 0.019 kg

Operating temperature -20 ~ +85 °C

Storage temperature -25 ~ +125 °C

●●● Current Sensor Module

•Nominal current measurement: from 1.0A DC, AC •Excellent linearity: 15 ppm •High resolution •Very low offset drift •Overall accuracy at IPN @ +25°C: ≤±0.1 % •Wide frequency bandwidth up to 100 kHz (- 3 dB) •RoHS Compliant

Main characteristics

•DC, AC pulse currents' measurements with galvanic isolation •Nano Crystal Fluxgate technology •Electrostatic shield between primary and secondary circuit •Bipolar Power supply ±15 Volt •Operating temperature range from -20 to +85°C •Wire Connector Type•Current output •Really quick response time (<100 ns)

Features

•�Typical applications: ELCB, RCB, ACB, Photovoltaics, Electric Vehicle, Rapid Transit Railway•Feedback element in precision current regulated devices (power supplies…)•Precise and high stability inverters•Medical equipment•Energy measurement•Power analyzers

Standard compliance

•Current overload capability •Additional output indicating the transducer state

Remarks

Page 13: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

www.cobon.co.kr l 13

CF100AD (05~35)

Nominal primary current (IPN) 100A A r.m.s.

Measuring range @ ±5V (±5%) ±120 A peak

Max. measuring resistance @ IP max & ±5V (±5%) 20 Ω

Min. measuring resistance @ IPN & ±5V (±5%) 1 Ω

Turn number 1500 Turn

Secondary current at IPN 100/1500 A

Accuracy at IPN @ +25°C ≤±0.1 %

Accuracy at IPN @ -5 ~ +85°C ≤±0.2 %

Accuracy at IPN @ -20 ~ +85°C ≤±0.5 %

Offset current @ +25°C ≤±100 uA

Linearity ≤±0.05 %

Bandwidth @ -3dB ≤300 kHz

Max. no-load consumption current @ ±5V (±5%) ≤20 mA

Secondary resistance @ +85°C ≤100 Ω

Dielectric strength Primary/Secondary @ 50Hz, 1min 3 kV

Supply voltage @ ±5% ±15V V dc

Voltage drop ≤3 V

Mass 0.039 kg

Operating temperature -20 ~ +85 °C

Storage temperature -25 ~ +125 °C

●●● Current Sensor Module

•Nominal current measurement: from 1.0A DC, AC •Excellent linearity: 15 ppm •High resolution •Very low offset drift •Overall accuracy at IPN @ +25°C: ≤±0.1 % •Wide frequency bandwidth up to 100 kHz (- 3 dB) •RoHS Compliant

Main characteristics

•DC, AC pulse currents' measurements with galvanic isolation •Nano Crystal Fluxgate technology •Electrostatic shield between primary and secondary circuit •Bipolar Power supply ±15 Volt •Operating temperature range from -20 to +85°C •Wire Connector Type•Current output •Really quick response time (<100 ns)

Features

•�Typical applications: ELCB, RCB, ACB, Photovoltaics, Electric Vehicle, Rapid Transit Railway•Feedback element in precision current regulated devices (power supplies…)•Precise and high stability inverters•Medical equipment•Energy measurement•Power analyzers

Standard compliance

•Current overload capability •Additional output indicating the transducer state

Remarks

Page 14: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

14 l Cobontech Co., Ltd.

Arc Current Sensor Module

ARC10A

RCCBELB

9.996A

0.004A

L1 L2 L1 L2

ZCT

CT2CT1

CT2CT1

5V

50A

5V

100mA

5V

50A

5V

100mA

No arc signal

AC wave

Arc signal

5V

50A

5V

100mA

CT current detection

ZCT Signal of Earth leakage

Signal Amp

Signal Amp

Full Wave Rectification

Full Wave Rectification

Waveform shaping (DC)

Waveform shaping (DC)

OUTPUT (0~5V)

Wave OutAC detection

OUTPUT (0~5V)

CIRCUIT DIAGRAM

CHARACTERISTICS Arc Sensor Module

Normal primary current(IPN) Ar.m.s(A eff.) 50A

Output Voltage Vdc 0 ~ 5V

Wide frequency bandwidth (- 3 dB) 200 kHz

Bipolar Power supply ±12 Volt

Operating temperature range -45 to +85°C

CHARACTERISTICS

Page 15: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

www.cobon.co.kr l 15

Lighting Surge Sensor Module

CIRCUIT DIAGRAM

SPD

100KA

t 100KA

5V

5V

50A

5V

100mA

No arc signal

50A

5V

CT Surge Detect Signal Amp Peak Hold Waveform

shaping(DC)OUTPUT(0~5V)

CT CurrentDetect Signal Amp Full Wave

RectificationWaveform

shaping (DC)OUTPUT (0~5V)

CHARACTERISTICS

CHARACTERISTICS Surge Sensor Module Current Sensor Module

Normal primary current(IPN) Ar.m.s(A eff.) 0.1 ~ 100KA 0.01 ~ 100mA

Output Voltage Vdc 0 ~ 5V 0 ~ 5V

Wide frequency bandwidth (- 3 dB) 200 kHz 200 kHz

Pulse Time 1 ~ 1000uSec 1 ~ 10mSec

Bipolar Power supply ±15 Volt ±12 Volt

Operating temperature range -45 to +85°C -45 to +85°C

Page 16: EARTH LEAKAGE DETECTION MODULE CURRENT SENSOR MODULE · •Built-in thyristor (MCR100-8) •High noise immunity, Large surge margin •5P HIC package by FR4 Resistive leakage current

28578, 501, Techno S Tower, 530, Jikji-daero, Heungdeok-gu, Cheongju-si, Chungcheongbuk-do, KoreaTel. 82-43-838-9747 / Fax. 82-31-629-5572e-mail. [email protected] / www.cobon.co.kr

ISO9001 : 2008ISO14001 : 2004

TUV compliant

RoHs

Printed in May 2019