E2 EDGELIGHT LED EXIT SIGN Note: This sign is configured for maintained operation only. Non-Maintained (switched active) operation is available by special order. Specifications: Catalogue Number Network Type Mounting Colour Decal Supply Voltage Input Power 684730 None (SPU) Recessed mounted White Running man* 230-240V a.c. 50Hz 2.7W (high rate charge) 2.3W (low rate charge) 684730/D DALI 684740 Axiom 684731 None (SPU) Surface mounted White Running man* 684731/D DALI 684741 Axiom 684732 None (SPU) Surface mounted White None (ordered seperately) 684742 Axiom 684733 None (SPU) Surface mounted Black Running man theatre (green on black) 684733/D DALI 684743 Axiom Surface-mounted Recessed 1 *4 decals are provided - Running Man, Running Man Left, Running Man Right, Opaque white

E2 EDGELIGHT LED EXIT SIGNdocuments.portalink.net/product/1774161/LE07219AAC E2 LED... · 2020. 7. 22. · E2 EDGELIGHT LED EXIT SIGN Note: This sign is configured for maintained

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: E2 EDGELIGHT LED EXIT SIGNdocuments.portalink.net/product/1774161/LE07219AAC E2 LED... · 2020. 7. 22. · E2 EDGELIGHT LED EXIT SIGN Note: This sign is configured for maintained

E2 EDGELIGHT LED EXIT SIGN

Note:

This sign is configured for maintained operation only.Non-Maintained (switched active) operation is available by special order.

Specifications:

Catalogue Number Network Type Mounting Colour Decal Supply Voltage Input Power

684730 None (SPU)

Recessed mounted White Running man*

230-240V a.c. 50Hz 2.7W (high rate charge)2.3W (low rate charge)

684730/D DALI

684740 Axiom

684731 None (SPU)

Surface mounted White Running man*684731/D DALI

684741 Axiom

684732 None (SPU)

Surface mounted White None(ordered seperately)

684742 Axiom

684733 None (SPU)

Surface mounted Black Running man theatre (green on black)

684733/D DALI

684743 Axiom

Surface-mounted Recessed

1

*4 decals are provided - Running Man, Running Man Left, Running Man Right, Opaque white

Page 2: E2 EDGELIGHT LED EXIT SIGNdocuments.portalink.net/product/1774161/LE07219AAC E2 LED... · 2020. 7. 22. · E2 EDGELIGHT LED EXIT SIGN Note: This sign is configured for maintained

Surface- and Recessed Mounted

NOTE: To make decal replacement easier, remove body from mounting plate.

Lift tab to release then slide plate from body.

Slide out

Once decal is changed, slide decal assembly over lens

How to replace decal/s before installing body to bracket

Step 1: Use 3mm slot screwdriver to detach original decal. Depress metal clips at each end to release the decal cover assembly.

Step 4: Decal assembly will lock into place.

Step 2: Clean the lens before inserting decal.

Press test switch for local test when installation is complete. Axiom version has 2 LED’s SPU and DALI versions have 1 LED LED colour- refer to separate page.Ensure correct orientation. Terminal Block will be at opposite end to LED & Test Switch.

CLICK

Step 3: Once decal is changed, slide decal assembly over lens to click into position.

E2 EDGELIGHT LED EXIT SIGN

A new concealed Antenna is fitted within the body of the Axiom versions. Any fitting orientation is allowed.

2

Page 3: E2 EDGELIGHT LED EXIT SIGNdocuments.portalink.net/product/1774161/LE07219AAC E2 LED... · 2020. 7. 22. · E2 EDGELIGHT LED EXIT SIGN Note: This sign is configured for maintained

Surface Mounted

Step 1: Fit the required decal/s as described on page 2.Step 2: Secure the mounting plate to the wall or ceiling.

Step 3c: Fit the protective cover to the cableway.

Step 3a: Terminate Unswitched Active, Neutral and Earth supply cables to terminal block.

Step 3b: Terminate DALI cables to terminal block (DALI models only)

Step 4b: Locate and slide cover horizontally towards the terminal block until it connects securely.

Ceiling mounted

SEE DETAIL A

SCALE 2.000DETAIL A

CLICK

! Switched Active and unswitched active must be on same phaseFor 24/7 ‘Maintained’ operation, link switched active with unswitched active

CLICK

SEE DETAIL A

SCALE 2.000DETAIL A

CLICK

! Switched Active and unswitched active must be on same phaseFor 24/7 ‘Maintained’ operation, link switched active with unswitched active

CLICK

SEE DETAIL A

SCALE 2.000DETAIL A

CLICK

! Switched Active and unswitched active must be on same phaseFor 24/7 ‘Maintained’ operation, link switched active with unswitched active

CLICK

Slide body this way

Step 5: Apply power to the sign and confirm that: • Indicator LED is flashing. • Running Man is illuminated.

To remove the body from mounting plate, push tab up and slide out the body as shown.

Slide body

Removal

Step 4a: Fit the body to the mounting plate by raising it to ceiling level.

E2 EDGELIGHT LED EXIT SIGN

3

Page 4: E2 EDGELIGHT LED EXIT SIGNdocuments.portalink.net/product/1774161/LE07219AAC E2 LED... · 2020. 7. 22. · E2 EDGELIGHT LED EXIT SIGN Note: This sign is configured for maintained

E2 EDGELIGHT LED EXIT SIGN

LE07

219A

AC

Customer ServiceFor all Customer Service and Technical Support enquires please call Monday to Friday during business hours.

HPM Legrand Australia 1300 369 777 www.legrand.com.au

Recessed Edgelight

Product Legacy Upgrade Options: Where possible, Legrand develops replacement sub-assemblies of latest generation light source and electronics for the upgrading of obsolete items from previous generations. 682026: A special adaptor plate has been designed enabling the new E2 Recessed Edgelight to be installed in place of the discontinued Optica Bladelight Recessed fluorescent exit sign.

Step 5: Terminate the Unswitched Active, Neutral and Earth supply cables to the terminal block on the plate provided or fit an Australian approved flex and 3-pin plug as required, enlarging the selected entry hole to suit a cable gland. Terminate DALI cables to the terminal block (DALI models only).

Step 6: Fit the protective cover to the cableway and secure the slide-on cover to the Exit body as described previously.

Replacement Parts:

Step 7: Note the orientation of the plate so that the LED and Test Switch will be most visible and accessible. Plug in the fixture before fixing the luminaire and recessing plate securely to the ceiling using the swing clamps provided.Don’t over-tighten the screws or damage to the ceiling tile may occur.

Step 1: Fit the required decal/s as described previously.

Step 2: Ensure Unswitched Active is available adjacent to where the sign will be installed.

Step 3: Determine a compliant location before cutting.

Step 4: Use the cut-out template provided to cut an exact opening.

HPM Legrand New Zealand 0800 476 009 www.legrand.co.nz

ABN: 31 000 102 661

686240 Battery Pack AA4LNICD 686218 Decal - Running Man Left

684736 E2 Recessing Plate Kit WE 686219 Decal - Running Man Right

684737 E2 Mounting Block Kit WE 686220 Decal - Running Man Theatre (Green on Black)

684738 E2 Recessing Plate Kit Black 686219 Decal - Running Man Right

684739 E2 Mounting Block Kit Black 686228 Decal - Opaque (no light transmitted)

685735 Lens Replacement Kit 686229 Decal - Black Opal (translucent)

686217 Decal - Running Man 686230 Decal - Custom Printing

682026 E2 conversion plates (2 pcs) to enable upgrade from discontinued Recessed Optica Bladelight Exit.

685735 684737 686240684736

4

07/2

016

HP

ML0

934

100mm

418mm