Chillgard L Series
The refrigerant The refrigerant monitoring industry monitoring industry leaderleader
Home of proven, reliableHome of proven, reliablePhotoacoustic Infrared Photoacoustic Infrared TechnologyTechnology
Chillgard L Series
Photoacoustic sensor is stable and sensitive
Improved PIR sensingImproved PIR sensing Sample system minimizes moving
parts, no solenoid valves or mechanical flow switch
RS-485 & Digital Signal Processing New advances in New advances in
micro-machined technologymicro-machined technology Water and Corrosion resistant plastic
enclosure
Chillgard L Series
Features a new optical bench Micro-machined optics
Significant technological advancement
Used on all Chillgard LS and LE Gas Monitors
Improved reliability 2-year warranty
Backwards-compatible with existing units
Chillgard L Series - Flexibility
Flexibility to meet: Refrigerant Monitoring needs Remote Signaling and Control Power Requirements Budget
Chillgard L Series
Chillgard LS Refrigerant Monitor Economical low level monitoring
of refrigerant gases Sensor unit with analog and digital output
Chillgard LC Control Module Controls up to 8 Chillgard LS Sensors Multiple outputs and relays
Chillgard LE Refrigerant Monitor Combined features of Chillgard LS and LC
Gas Monitors within one enclosure
Combined multi-point sensing and controlling
Chillgard LS Monitor
Photoacoustic IR sensorPhotoacoustic IR sensor
Standard gases – R123, Standard gases – R123, R134a, R11, R12, R22R134a, R11, R12, R22
Minimum detection level - Minimum detection level - 20ppm20ppm
Single-point diffusion or 4-Single-point diffusion or 4-point pumped modelspoint pumped models
Chillgard LS
Compliant with ANSI/ASHRAE 15Compliant with ANSI/ASHRAE 15 UL approvalUL approval Water- and corrosion-resistant plastic enclosureWater- and corrosion-resistant plastic enclosure Easy operation, installation and maintenanceEasy operation, installation and maintenance 2-year warranty2-year warranty
Chillgard LS
24 VAC/DC or 110/220 VAC power24 VAC/DC or 110/220 VAC power 5 LEDs indicate power, fault and 3 levels of 5 LEDs indicate power, fault and 3 levels of
alarmalarm 4-20 mA and RS-485 outputs (to Chillgard LC 4-20 mA and RS-485 outputs (to Chillgard LC
Controller)Controller)
Chillgard LS Optional Gases
R400 and R500 series of refrigerantsR400 and R500 series of refrigerants Blends of multiple refrigerants to obtain good Blends of multiple refrigerants to obtain good
thermodynamic properties in the chiller, with thermodynamic properties in the chiller, with reduced corrosion and ozone depletion reduced corrosion and ozone depletion potential.potential.
Includes R404a, R410a, R407c, R507 Includes R404a, R410a, R407c, R507 Order with custom calibrationOrder with custom calibration Other refrigerants possibleOther refrigerants possible
Chillgard LS Accessories
AccessoriesAccessories Unit-mounted strobeUnit-mounted strobe Calibration boxCalibration box Remote light towersRemote light towers Calibration kitsCalibration kits Chillgard LC ControllerChillgard LC Controller
Maintenance and Repair
• No moving parts in diffusion-modeNo moving parts in diffusion-modeChillgard LS MonitorChillgard LS Monitor
• Optical bench is field-replaceable for convenient Optical bench is field-replaceable for convenient repair and for detection of a different refrigerantrepair and for detection of a different refrigerant
Chillgard LS Summary
Low cost refrigerant sensor Improved PIR technology Easy to install, operate and maintain Can be stand-alone or used with
Chillgard LC Controller
Chillgard LC Control Module
Capable of controlling up to 8 Chillgard LS Capable of controlling up to 8 Chillgard LS SensorsSensors
Easy-to-use digital display with 4-button keypadEasy-to-use digital display with 4-button keypad Provides gas reading, alarm status, calibration and Provides gas reading, alarm status, calibration and
fault diagnosticsfault diagnostics
Water- and corrosion-resistant enclosureWater- and corrosion-resistant enclosure
Chillgard LC Features
4-20mA and RS-232 output4-20mA and RS-232 output 0-10 V point identifier output0-10 V point identifier output 4 relays - 3 levels of alarm + fault4 relays - 3 levels of alarm + fault 85 dB horn, 100 dB horn option85 dB horn, 100 dB horn option
Chillgard LS & LC
• Twisted pair RS-485, 18 GA wire up to 1000 ftTwisted pair RS-485, 18 GA wire up to 1000 ft• Modbus protocolModbus protocol• LC can communicate with up to 8 single-point LC can communicate with up to 8 single-point
LS monitors, two 4-point LS monitors, or any LS monitors, two 4-point LS monitors, or any combinationcombination
Powering the Chillgard LS
Power locally via 24 VAC or DC Power locally via 110/220 VAC optional supply Power via Chillgard LC Control Module
Powering the Chillgard LC
24 VAC or DC 110/220 VAC optional supply
Can be used to power one Chillgard LS Monitor
Powering the Chillgard LC
Transformer version Powers Chillgard LC Monitor
and up to 5 Chillgard LS Sensors
Powering Chillgard L Series
24 VAC/DC available24 VAC/DC available
24 VAC/DC 24 VAC/DC 24 VAC/DC24 VAC/DC
RS 485RS 485
Chillgard L Series Power Options
110/220 VAC Available110/220 VAC Available
110/220 V 110/220 V inputinput
110/220 V 110/220 V inputinput
With internal 110/220 VAC With internal 110/220 VAC power supplypower supply
With internal 110/220 With internal 110/220 VAC power supplyVAC power supply
RS 485RS 485
Chillgard L Series Power Options
110/220 VAC Available110/220 VAC Available
110/220 V 110/220 V inputinput
4-conductor cable4-conductor cable
24 VDC from 24 VDC from LCLC
With internal 110/220 With internal 110/220 VAC power supplyVAC power supply
For 1 sensor module, up to 100’ using 18 AWG wireFor 1 sensor module, up to 100’ using 18 AWG wire
Chillgard L Series Power Options
110/220 VAC AVAILABLE110/220 VAC AVAILABLE
LC transformer versionLC transformer version
110/220 V 110/220 V InputInput
RS 485RS 48524 VAC24 VAC
RS 485RS 48524 VAC24 VAC
24 VAC24 VACRS 485RS 485
w/internal transformerw/internal transformer
Transformer version powers up to 5 diffusion Chillgard LS Monitors Transformer version powers up to 5 diffusion Chillgard LS Monitors or two 4-point pumped Chillgard LS Monitorsor two 4-point pumped Chillgard LS Monitors
Chillgard LC
AccessoriesAccessories Unit mounted strobeUnit mounted strobe Remote light towersRemote light towers Calibration kitsCalibration kits
Chillgard LC Summary
Low cost controller Controls up to 8 Chillgard LS sensors Multiple outputs Configurable to meet your needs Easy to install, operate and maintain
Chillgard LE Features
Combined features of Chillgard LS and LCCombined features of Chillgard LS and LC products in one enclosure products in one enclosure
Combined multi-point sensing and controllingCombined multi-point sensing and controlling
Chillgard LE Features
Photoacoustic IR sensorPhotoacoustic IR sensor
Standard gases – R123, R134a, Standard gases – R123, R134a, R11, R12, R22R11, R12, R22
Minimum detection level - Minimum detection level - 20ppm20ppm
Single-point diffusion, single-Single-point diffusion, single-point pumped or 4-point pumped point pumped or 4-point pumped modelsmodels
Chillgard LE Features
Complies with Complies with ANSI/ASHRAE 15ANSI/ASHRAE 15
UL approvalUL approval Water- and corrosion-Water- and corrosion-
resistant plastic enclosureresistant plastic enclosure Easy to operate, install and Easy to operate, install and
maintainmaintain 2-year warranty2-year warranty
Chillgard LE Features
24 VAC/DC or 110/220 VAC power24 VAC/DC or 110/220 VAC power Easy-to-use digital display with 4-button keypadEasy-to-use digital display with 4-button keypad
Provides gas reading, alarm status, Provides gas reading, alarm status, calibration and fault diagnostics calibration and fault diagnostics
Water- and corrosion-resistant enclosureWater- and corrosion-resistant enclosure
Chillgard LE Features
4-20mA and RS-232 output4-20mA and RS-232 output 0-10 V point identifier output0-10 V point identifier output 4 relays - 3 levels of alarm + fault4 relays - 3 levels of alarm + fault 85 dB horn, 100 dB horn option85 dB horn, 100 dB horn option
Chillgard LE Gases
R400 and R500 series of refrigerantsR400 and R500 series of refrigerants Blends of multiple refrigerants to obtain Blends of multiple refrigerants to obtain
good thermodynamic properties in the good thermodynamic properties in the chiller, with reduced corrosion and chiller, with reduced corrosion and ozone depletion potential.ozone depletion potential.
Includes R404a, R410a, R407c, R507 Includes R404a, R410a, R407c, R507 Order with custom calibrationOrder with custom calibration Other refrigerants possibleOther refrigerants possible
Chillgard LE Summary
Low cost refrigerant sensor Improved PIR technology Multiple outputs Configurable to meet your needs Easy to install, operate and
maintain
Chillgard L Series Summary
EffectiveEffective: Meets ASHRAE standards for : Meets ASHRAE standards for refrigerant monitoring refrigerant monitoring
FlexibleFlexible: Configurable to meet application needs: Configurable to meet application needs AdvancedAdvanced: Photoacoustic infrared bench design: Photoacoustic infrared bench design EfficientEfficient: Detects low levels of refrigerant gas : Detects low levels of refrigerant gas
with low cost of ownership with low cost of ownership