GARAGE SLAB 18'-2 5/16" 14'- 3/4" 12'-8 1/4" 10'-6 1/4" 12'-3 13/16" 3'-11 15/16" 17'-7 5/16" 6'-2 9/16" 9'-0" 3'-8 5/8" 2'-6" 5'-8" 10'-0" 6'-4 1/16" 6'-4" 10'-1 1/2" 32'-4" 20'-8" 13'-2 3/8" 10'-8" 2'-0" 8'-4" 10'-0" 2'-6" 17'-4 3/4" 12'-8" 13'-2 3/8" 9'-8 15/16" 16" O.C. Spacing Start 2'-0" 15'-8 15/16" J7 J23 J5 J6 J4 J23 J7 J7 J5 J5 J23 J5 J6 J23 J4 J8 J6 J7 J8 J9 J8 J5 J23 J23 J5 J6 J4 J22 J6 J9 J11 J9 J8 J5 Continuous Strongback 2 X 6 Continuous Strongback 2 X 6 Continuous Strongback 2 X 6 Continuous Strongback 2 X 6 Continuous Strongback 2 X 6 Continuous Strongback 2 X 6 Continuous Strongback 2 X 6 Continuous Strongback 2 X 6 Continuous Strongback 2 X 6 G26 G24 G9 G5 G9 G24 G9 G2 G5 G17 G9 G6 G11 G11 G11 G27 G9 G5 G5 G11 G5 G27 G6 G5 G24 G17 G11 G3 G8 G9 G24 G5 G9 G5 G6 G9 G5 G3 G9 G8 G9 G25 G2 G25 G2 G5 G8 G6 G5 G5 G5 G24 G5 G2 G8 G2 G1 G16 G11 G24 G9 G5 G9 G9 G9 G5 G24 G3 G10 G11 G26 G9 G24 G27 G8 G24 G17 G24 G4 G24 G3 G28 G9 G11 G11 G3 G3 G25 G9 G11 G9 G24 G1 C28 TUL: 681.1 C82 TUL: 8354.6 C18 TUL: 7982 C17 TUL: 9154.3 C99 TUL: 0 C87 TUL: 3203.7 C61 TUL: 1436.3 C100 TUL: 3164.8 C54 TUL: 6733.6 C74 TUL: 0 C137 TUL: 5867.4 C19 TUL: 5001.1 C6 TUL: 6530.2 C101 TUL: 7915.4 C2 TUL: 673.1 C55 TUL: 1074.6 C49 TUL: 117.3 C13 TUL: 3833.8 C24 TUL: 9534.5 C44 TUL: 0 C20 TUL: 10981.8 C112 TUL: 1571.4 C94 TUL: 7277.2 C66 TUL: 3679.4 C63 TUL: 0 C34 TUL: 1011.9 C22 TUL: 2203.2 C15 TUL: 28.7 C90 TUL: 3834.4 C14 TUL: 2252.1 C26 TUL: 1521.9 C7 TUL: 3827 C71 TUL: 723.9 C84 TUL: 7396.1 C56 TUL: 791.4 C105 TUL: 432.2 C109 TUL: 0 C48 TUL: 626.9 C80 TUL: 5184.8 C10 TUL: 2189.9 C3 TUL: 3026.2 C79 TUL: 2948.4 C39 TUL: 4960.1 C47 TUL: 2377.7 C50 TUL: 4406.7 C65 TUL: 2231.3 C40 TUL: 4708 C46 TUL: 8038.1 C8 TUL: 0 C52 TUL: 0 C30 TUL: 4840.7 C16 TUL: 2349.8 C113 TUL: 3463 C111 TUL: 2167.1 C45 TUL: 71.9 C32 TUL: 4050.8 C21 TUL: 3155.2 C37 TUL: 0 C51 TUL: 346.7 C42 TUL: 1246.1 C35 TUL: 93.2 C9 TUL: 6044.3 C38 TUL: 0 C11 TUL: 0 C58 TUL: 4390.4 C25 TUL: 1531.6 C88 TUL: 461.3 C12 TUL: 70.7 C41 TUL: 3014.2 C93 TUL: 4126 C72 TUL: 4685.5 C5 TUL: 5218.5 C4 TUL: 12047.7 C33 TUL: 466.3 C29 TUL: 2011.1 C98 TUL: 3367.8 C83 TUL: 3193.3 C102 TUL: 2469.3 C36 TUL: 36.8 C27 TUL: 669 C97 TUL: 3237.9 C43 TUL: 0 C23 TUL: 982.8 C73 TUL: 0 C31 TUL: 1684.7 Start Joist Run USLR0029S_Rev2 See your local building code in effect for minimal bottom chord bracing. ENGINEERING Design Method ASD Floor Loads Live 40 PSF Dead 15 PSF Construction 0 PSF Floor Deflection LL Girder L/360 LL Joist L/480 DL Girder L/360 DL Joist L/360 TL Girder L/240 TL Joist L/240 Floor Deck and Vibration Deck: 3/4" SPF Plywood, Nailed & Glued Ceiling: None Strapping: no strapping PROJECT/JOB NUMBER USLR0029 CUSTOMER NAME US LUMBER CREATED DATE 9/3/2015 2:15:10 PM DRAWN BY EWP JOB NAME CILIBERTO RESIDENCE WARNING FOR A PROPER INSTALLATION(TOP AND BOTTOM) Please refer to the stamp on the joist to install them in the right position Reinforcement For reinforcement please refer to the calculation sheets HANGER SCHEDULE LVL/JOIST QTY DESCRIPTION G26 2 CUSTOM HUS212-2 G27 2 CUSTOM HUS212-2 G24 8 CUSTOM HUS212-2 G17 2 CUSTOM HUSR/L410 G8 1 CUSTOM HUSR/L414 G11 1 CUSTOM HUSR/L414 G1 1 CUSTOM HUSR/L414 G5 1 CUSTOM HUSR/L414 J8 3 CUSTOM SUR/L2.56/14 J22 1 CUSTOM SUR/L2.56/14 J23 9 CUSTOM SUR/L2.56/14 J7 1 CUSTOM SUR/L2.56/14 J9 2 CUSTOM SUR/L2.56/14 J5 5 CUSTOM SUR/L2.56/14 J6 4 CUSTOM SUR/L2.56/14 J4 1 CUSTOM SUR/L2.56/14 G6 3 Simpson HGUS414 14 G5 3 Simpson HGUS414 14 G10 1 Simpson HGUS414 14 G2 1 Simpson HGUS414 14 G3 4 Simpson HGUS414 14 G11 2 Simpson HGUS414 14 G4 2 Simpson HGUS414 14 J11 18 Simpson IUS2.56/14 14 J9 56 Simpson IUS2.56/14 14 J8 51 Simpson IUS2.56/14 14 J5 43 Simpson IUS2.56/14 14 J23 7 Simpson IUS2.56/14 14 J7 47 Simpson IUS2.56/14 14 J6 92 Simpson IUS2.56/14 14 J22 1 Simpson MIU2.56/14 14 J4 2 Simpson MIU2.56/14 14 J4 3 Simpson SUR/L2.56/14 14 Continuous Strongback DESCRIPTION TOT. LIN. FT. Continuous Strongback 2 X 6 204 JOIST SCHEDULE LABEL QTY DESCRIPTION PLIES R/LEN J22 1 NI-40X 14 1 4' J4 3 NI-40X 14 1 3' Total length: 13' J9 29 OJ-314 14 1 16' J23 8 OJ-314 14 1 6' J8 27 OJ-314 14 1 14' J6 48 OJ-314 14 1 10' J5 24 OJ-314 14 1 8' J7 24 OJ-314 14 1 12' Total length: 1850' J11 9 OJ-315 14 1 18' Total length: 162' LVL SCHEDULE LABEL QTY DESCRIPTION PLIES R/LEN G8 5 PW LVL-2.0E 1.75 X 14 2 9' G6 4 PW LVL-2.0E 1.75 X 14 2 3' G9 18 PW LVL-2.0E 1.75 X 14 2 7' G11 10 PW LVL-2.0E 1.75 X 14 2 8' G10 1 PW LVL-2.0E 1.75 X 14 2 2' G2 5 PW LVL-2.0E 1.75 X 14 2 10' G1 2 PW LVL-2.0E 1.75 X 14 2 5' G3 6 PW LVL-2.0E 1.75 X 14 2 11' G5 16 PW LVL-2.0E 1.75 X 14 2 6' G4 1 PW LVL-2.0E 1.75 X 14 2 13' Total length: 1000' NOTES 1. THIS JOIST PLACEMENT GUIDE IS FOR "TRIFORCE" PRODUCTS ONLY. 2. THIS JOIST PLACEMENT GUIDE SHOULD BE REVIEWED BY THE ARCHITECT, ENGINEER OF RECORD OR BUILDER TO ENSURE THAT NO ADDITIONAL ROOF LOADS WILL BE TRANSFERRED ONTO THE FLOOR SYSTEM AND THAT THE FOUNDATION DESIGN ACCOUNTS FOR ALL LOADS. 3. THIS JOIST PLACMENT GUIDE IS PROVIDED FOR THE SOLE PURPOSE OF MATERIAL REFERENCE ONLY. THE BUILDING DESIGNER AND/OR PROJECT COORDINATOR IS THE PROJECTS SOLE REPSONSIBLE PARTY AND ALL SPANS, LOCATIONS, LOADING FOR JOISTS, BEAMS, LENGTHS AND QUANTITIES SHOULD BE VERIFIED PRIOR TO ORDERING. 4. THIS JOIST PLACEMENT GUIDE MAY HAVE BEEN DESIGNED WITH OR WITHOUT FULL STRUCTURAL PLANS AND SHOULD BE REVIEWED BY THE ARCHITECT AND/OR THE ENGINEER OF RECORD TO ENSURE STRUCTURAL INTEGRITY. "TRIFORCE" CAN NOT BE REPSPONSIBLE FOR FIELD FRAMING AND BRACING LOCATIONS NOT SPECIFIED ON THE ORIGINAL PLANS. THE PROJECTS SOLE RESPONSIBLE PARTY IS TO TRANSFER ALL ROOF LOADS TO FOUNDATIONS. 5. ALL "TRIFORCE" PRODUCTS DETAILS APPLY TO ALL REVELANT OCCURENCES WHETHER OR NOT THEY ARE SPECIFICALLY INDICATED ON THE PLACEMENT GUIDE. 6. CONTRACTOR TO COORDINATE WITH MECHANICAL, ELECTRICAL, AND ARCHITECTURAL DRAWINGS FOR THE LOCATIONS AND SIZES OF FLOOR/ROOF OPENINGS, WHICH WILL AFFECT THE LOCATION OF JOISTS AND BEAMS. 7. CONTRACTOR TO ADVISE "MANUFACTURERS" OF ANY MODIFICATIONS AND/OR CHANGES TO THIS JOIST AND BEAM PLACEMENT GUIDE. 8. JOISTS SHALL BE ERECTED AND FASTENED IN A STRAIGHT AND PLUMB POSITION. 9. DO NOT CUT, DRILL, OR NOTCH THE TOP OR BOTTOM CHORD OF THE JOISTS. 10. DO NOT CUT, DRILL, OR NOTCH BEAMS. 11. FIELD BRACING IS NOT THE RESPONSIBILITY OF THE "TRIFORCE" FABRICATOR, SUPPLIER, OR DESIGNER. FIELD PERSONEL ERECTING JOISTS ARE CAUTIONED TO SEEK PROFFESIONAL ADVICE REGARDING TEMPORARY ERECTION BRACING WHICH IS "ALWAYS REQUIRED" TO PREVENT TOPPLING AND DOMINOING IN SPECIFIC APPLICATIONS. 12. WHERE NO DIRECT TOP CHORD SHEATHING IS DIRECTLY APPLIED, JOISTS MUST BE BRACED AT 2'-0" O.C. MAXIMUM. WHERE NO BOTTOM CHORD SHEATHING IS DIRECTLY APPLIED, JOISTS MUST BE BRACED AT 10'-0" O.C. MAXIMUM. 13. ALL JOISTS AND LVL BEAMS MUST BE USED IN A DRY ENVIROMENT AND PROTECTED FROM MOISTURE. 14. JOISTS MUST BE HANDLED WITH EXTREME CARE DURING ERECTION TO PREVENT DAMAGE OR PERSONAL INJURY. REFER TO JOIST ENGINEERING FOR CONNECTION AND BRACING REQUIRMENTS. THESE CALCULATIONS ARE SUPPLIED FOR THE ENGINEER OF RECORD TO ADEQUATELY PROVIDE FOR CONNECTION AND INTEGRATION OF THE ROOF ASSEMBLY TO THE SUPPORTING STRUCTURE. DESIGNERS OF SUPPORTING CONNECTIONS ARE "SOLEY" RESPONSIBLE FOR THE INTEGRITY OF THEIR PRODUCT(S). 15. ALL JOIST AND BEAMS MUST HAVE FULL BEARING CONTACT IN HANGERS. ALL JOIST AND LVL HANGERS TO BE FASTENED AS PER "SIMPSON STRONG TIE" SPECIFICATIONS FOR MAXIMUM RESISTANCE. 16. WHEN TILE IS INSTALLED AS AN OPTION ON SECOND STORY APPLICATIONS. A L/600 DEFLECTION CRITERIA OR 16" ON CENTER SPACING WILL BE NECESSARY TO MAINTAIN TILE WARRANTY. 17. WHERE BEAMS ARE NOT THE SAME DEPTH AS THE JOISTS, LOCATE THE BEAM AT THE SAME ELEVATION AS THE TOP OF THE JOISTS. BUILD UP WALL AT BEARING POINTS OR BUILD UP BEAM WITH A COMBINATION OF 2X'S AND PLYWOOD. 18. THE FOLLOWING PRODUCT EVALUATIONS, ISSUED FOR "TRIFORCE" ARE RECOGNIZED BY BOCA, IBC, IRC, SBC, AND UBC REPORT NO. ESR-2999 "TRIFORCE" IS A MEMBER OF THE WOOD TRUSS COUNCIL OF AMERICA THIRD PARTY CERTIFICATION: INTERTEK TESTING SERVICES, WHICH USES THE WARNOCK HERSEY CERTIFICATION MARK FOR ENGINEERED WOOD PRODUCTS IS THE INDEPENDENT EVALUATION/TESTING AGENCY FOR CERTIFICATION OF "TRIFORCE" MANUFACTURING PROCESS. 19. WHEN SPECIFIC GRAVITY (DENSITY) IN SEISMIC ZONES IS SPECIFIED .05, SPF 2400 MSR WILL NEED TO BE SPECIFIED FOR ALL LENGTHS. PLEASE VERIFY WITH ENGINEER OF RECORD AND/OR LOCAL MUNICIPALITY. 20. MINIMUM BEAM SPECIFICATIONS FOR SUBSTITUTION SHOULD BE AS FOLLOWS MOE-2.0E6 PSI, FB 2800 PSI, AND FV 285 PSI. VERIFY WITH ENGINEER OF RECORD FOR VARIANCE. 21. ALL INTERIOR WALLS ARE ASSUMED TO BE NON LOAD BEARING UNLESS NOTED OTHERWISE. ALL LOADS ARE ASSUMED TO BE TRANSFERRED TO WALLS OR COLUMNS THAT STACK ALL THE WAY DOWN TO THE FOUNDATION. IF THIS IS NOT THE CASE, ADDITIONAL MATERIAL WILL BE REQUIRED!!! 22. JOIST PLACEMENT GUIDES AND ENGINEERING MAY NOT BE REPRODUCED IN PART OR IN FULL UNDER ANY CIRCUMSTANCES. OPEN JOIST TRIFORCE® and OPEN JOIST 2000® are in accordance with ICC 2009 and NDS-2010. OPEN JOIST TRIFORCE® and OPEN JOIST 2000® have been evaluated by ICC (report # ESR-2999) & (report # ESR-1035) and are quality controlled by a qualified third party agency. Parts are joined together with phenol-resorcinol adhesives. Lumber used for diagonal and vertical web members is visually graded in-plant as per quality control manual. A sub-floor must be attached to the top chord member according to the building code. If specified, strong backs must be of dry lumber and attached to the joists, according to current practice. Required bearing length must be determined for each application based on specifications by the manufacturer and must never be less than 1.5 inches. OPEN JOIST 2000® must be used under dry conditions. Refer to the specifications by the manufacturer for details of installation FOR QUOTE ONLY! NOT FOR CONSTRUCTION! FLOOR/LEVEL NAME 1st Level QuickTools 5.4.1211.0 Reviewed For Code Compliance

E USLR0029 S Rev2 FOR QUOTE ONLY! NOT FOR CONSTRUCTION! · B 5/16" 3/4" 1/4" 1/4" 13/16" 15/16" 5/16" 9/16"-0" 5/8"-6"-8"-0" 1/16"-4" 1/2"-4"-8" 3/8"-8"-0" -4" -0"-6" 3/4"-8" 3/8"

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

  • GARAGE SLAB

    18'-2

    5/1

    6"14

    '- 3/

    4"12

    '-8 1

    /4"

    10'-6

    1/4

    "12

    '-3 1

    3/16

    "3'

    -11

    15/1

    6"

    17'-7 5/16"

    6'-2 9/16"

    9'-0

    "3'

    -8 5

    /8"

    2'-6

    "

    5'-8

    "10

    '-0"

    6'-4

    1/1

    6"6'

    -4"

    10'-1 1/2"

    32'-4"

    20'-8"

    13'-2 3/8"

    10'-8"

    2'-0" 8'-4" 10'-0"

    2'-6

    "

    17'-4 3/4"

    12'-8"

    13'-2

    3/8

    "9'

    -8 1

    5/16

    "

    16" O.C.SpacingStart

    2'-0" 15'-8 15/16"

    J7

    J23

    J5

    J6

    J4J2

    3

    J7

    J7J5

    J5

    J23

    J5

    J6

    J23J4

    J8

    J6

    J7

    J8

    J9J8

    J5J2

    3

    J23

    J5

    J6

    J4

    J22

    J6

    J9J11

    J9

    J8

    J5

    Continuous Strongback 2 X 6Continuous Strongback 2 X 6

    Con

    tinuo

    us S

    trong

    back

    2 X

    6

    Continuous Strongback 2 X 6

    Continuous Strongback 2 X 6

    Continuous Strongback 2 X 6

    Continuous Strongback 2 X 6

    Continuous Strongback 2 X 6 Continuous Strongback 2 X 6

    G26

    G24

    G9

    G5

    G9

    G24

    G9

    G2

    G5

    G17

    G9

    G6

    G11

    G11

    G11

    G27

    G9

    G5

    G5

    G11

    G5

    G27

    G6

    G5

    G24

    G17

    G11

    G3

    G8

    G9

    G24

    G5

    G9

    G5

    G6

    G9

    G5

    G3

    G9

    G8

    G9

    G25

    G2

    G25

    G2

    G5

    G8

    G6

    G5

    G5

    G5

    G24

    G5

    G2

    G8

    G2

    G1

    G16

    G11

    G24

    G9

    G5

    G9

    G9

    G9

    G5

    G24

    G3

    G10

    G11

    G26

    G9

    G24

    G27

    G8

    G24

    G17

    G24

    G4

    G24

    G3

    G28

    G9

    G11

    G11

    G3

    G3

    G25

    G9

    G11

    G9

    G24

    G1

    C28TUL: 681.1

    C82TUL: 8354.6

    C18TUL: 7982

    C17TUL: 9154.3

    C99TUL: 0

    C87TUL: 3203.7

    C61TUL: 1436.3

    C100TUL: 3164.8

    C54TUL: 6733.6

    C74TUL: 0

    C137TUL: 5867.4

    C19TUL: 5001.1

    C6TUL: 6530.2

    C101TUL: 7915.4

    C2TUL: 673.1

    C55TUL: 1074.6

    C49TUL: 117.3

    C13TUL: 3833.8

    C24TUL: 9534.5

    C44TUL: 0

    C20TUL: 10981.8

    C112TUL: 1571.4

    C94TUL: 7277.2

    C66TUL: 3679.4

    C63TUL: 0

    C34TUL: 1011.9

    C22TUL: 2203.2

    C15TUL: 28.7

    C90TUL: 3834.4

    C14TUL: 2252.1

    C26TUL: 1521.9

    C7TUL: 3827

    C71TUL: 723.9

    C84TUL: 7396.1

    C56TUL: 791.4

    C105TUL: 432.2

    C109TUL: 0

    C48TUL: 626.9

    C80TUL: 5184.8

    C10TUL: 2189.9

    C3TUL: 3026.2

    C79TUL: 2948.4

    C39TUL: 4960.1

    C47TUL: 2377.7

    C50TUL: 4406.7

    C65TUL: 2231.3

    C40TUL: 4708

    C46TUL: 8038.1

    C8TUL: 0

    C52TUL: 0

    C30TUL: 4840.7

    C16TUL: 2349.8

    C113TUL: 3463

    C111TUL: 2167.1

    C45TUL: 71.9C32

    TUL: 4050.8

    C21TUL: 3155.2

    C37TUL: 0

    C51TUL: 346.7

    C42TUL: 1246.1

    C35TUL: 93.2

    C9TUL: 6044.3

    C38TUL: 0

    C11TUL: 0

    C58TUL: 4390.4

    C25TUL: 1531.6

    C88TUL: 461.3

    C12TUL: 70.7

    C41TUL: 3014.2

    C93TUL: 4126

    C72TUL: 4685.5

    C5TUL: 5218.5

    C4TUL: 12047.7

    C33TUL: 466.3

    C29TUL: 2011.1

    C98TUL: 3367.8

    C83TUL: 3193.3

    C102TUL: 2469.3

    C36TUL: 36.8

    C27TUL: 669

    C97TUL: 3237.9

    C43TUL: 0

    C23TUL: 982.8

    C73TUL: 0

    C31TUL: 1684.7Start Joist Run

    LAYOUT/MODEL NAME

    USLR0029S_Rev2

    See your local building code in effect forminimal bottom chord bracing.

    ENGINEERINGDesign Method ASD

    Floor LoadsLive 40 PSFDead 15 PSFConstruction 0 PSF

    Floor DeflectionLL Girder L/360LL Joist L/480DL Girder L/360DL Joist L/360TL Girder L/240TL Joist L/240

    Floor Deck and VibrationDeck: 3/4" SPF Plywood, Nailed & GluedCeiling: NoneStrapping: no strapping

    PROJECT/JOB NUMBERUSLR0029CUSTOMER NAMEUS LUMBERCREATED DATE9/3/2015 2:15:10 PM

    DRAWN BYEWP

    JOB NAMECILIBERTO RESIDENCE

    WARNING FOR A PROPER INSTALLATION(TOP AND

    BOTTOM)Please refer to the stamp on the joist to

    install them in the right position

    ReinforcementFor reinforcement please refer to the

    calculation sheets

    HANGER SCHEDULELVL/JOIST QTY DESCRIPTIONG26 2 CUSTOM HUS212-2G27 2 CUSTOM HUS212-2G24 8 CUSTOM HUS212-2G17 2 CUSTOM HUSR/L410G8 1 CUSTOM HUSR/L414G11 1 CUSTOM HUSR/L414G1 1 CUSTOM HUSR/L414G5 1 CUSTOM HUSR/L414J8 3 CUSTOM SUR/L2.56/14J22 1 CUSTOM SUR/L2.56/14J23 9 CUSTOM SUR/L2.56/14J7 1 CUSTOM SUR/L2.56/14J9 2 CUSTOM SUR/L2.56/14J5 5 CUSTOM SUR/L2.56/14J6 4 CUSTOM SUR/L2.56/14J4 1 CUSTOM SUR/L2.56/14G6 3 Simpson HGUS414 14G5 3 Simpson HGUS414 14G10 1 Simpson HGUS414 14G2 1 Simpson HGUS414 14G3 4 Simpson HGUS414 14G11 2 Simpson HGUS414 14G4 2 Simpson HGUS414 14J11 18 Simpson IUS2.56/14 14J9 56 Simpson IUS2.56/14 14J8 51 Simpson IUS2.56/14 14J5 43 Simpson IUS2.56/14 14J23 7 Simpson IUS2.56/14 14J7 47 Simpson IUS2.56/14 14J6 92 Simpson IUS2.56/14 14J22 1 Simpson MIU2.56/14 14J4 2 Simpson MIU2.56/14 14J4 3 Simpson SUR/L2.56/14 14

    Continuous StrongbackDESCRIPTION TOT. LIN. FT.Continuous Strongback 2 X 6 204

    JOIST SCHEDULELABEL QTY DESCRIPTION PLIES R/LENJ22 1 NI-40X 14 1 4'J4 3 NI-40X 14 1 3'

    Total length: 13'J9 29 OJ-314 14 1 16'J23 8 OJ-314 14 1 6'J8 27 OJ-314 14 1 14'J6 48 OJ-314 14 1 10'J5 24 OJ-314 14 1 8'J7 24 OJ-314 14 1 12'

    Total length: 1850'J11 9 OJ-315 14 1 18'

    Total length: 162'LVL SCHEDULE

    LABEL QTY DESCRIPTION PLIES R/LENG8 5 PW LVL-2.0E 1.75 X 14 2 9'G6 4 PW LVL-2.0E 1.75 X 14 2 3'G9 18 PW LVL-2.0E 1.75 X 14 2 7'G11 10 PW LVL-2.0E 1.75 X 14 2 8'G10 1 PW LVL-2.0E 1.75 X 14 2 2'G2 5 PW LVL-2.0E 1.75 X 14 2 10'G1 2 PW LVL-2.0E 1.75 X 14 2 5'G3 6 PW LVL-2.0E 1.75 X 14 2 11'G5 16 PW LVL-2.0E 1.75 X 14 2 6'G4 1 PW LVL-2.0E 1.75 X 14 2 13'

    Total length: 1000'

    NOTES1. THIS JOIST PLACEMENT GUIDE IS FOR "TRIFORCE" PRODUCTS ONLY.2. THIS JOIST PLACEMENT GUIDE SHOULD BE REVIEWED BY THE ARCHITECT, ENGINEER OF RECORD OR BUILDER TO

    ENSURE THAT NO ADDITIONAL ROOF LOADS WILL BE TRANSFERRED ONTO THE FLOOR SYSTEM AND THAT THEFOUNDATION DESIGN ACCOUNTS FOR ALL LOADS.

    3. THIS JOIST PLACMENT GUIDE IS PROVIDED FOR THE SOLE PURPOSE OF MATERIAL REFERENCE ONLY. THE BUILDINGDESIGNER AND/OR PROJECT COORDINATOR IS THE PROJECTS SOLE REPSONSIBLE PARTY AND ALL SPANS,LOCATIONS, LOADING FOR JOISTS, BEAMS, LENGTHS AND QUANTITIES SHOULD BE VERIFIED PRIOR TO ORDERING.

    4. THIS JOIST PLACEMENT GUIDE MAY HAVE BEEN DESIGNED WITH OR WITHOUT FULL STRUCTURAL PLANS ANDSHOULD BE REVIEWED BY THE ARCHITECT AND/OR THE ENGINEER OF RECORD TO ENSURE STRUCTURAL INTEGRITY."TRIFORCE" CAN NOT BE REPSPONSIBLE FOR FIELD FRAMING AND BRACING LOCATIONS NOT SPECIFIED ON THEORIGINAL PLANS. THE PROJECTS SOLE RESPONSIBLE PARTY IS TO TRANSFER ALL ROOF LOADS TO FOUNDATIONS.

    5. ALL "TRIFORCE" PRODUCTS DETAILS APPLY TO ALL REVELANT OCCURENCES WHETHER OR NOT THEY ARESPECIFICALLY INDICATED ON THE PLACEMENT GUIDE.

    6. CONTRACTOR TO COORDINATE WITH MECHANICAL, ELECTRICAL, AND ARCHITECTURAL DRAWINGS FOR THELOCATIONS AND SIZES OF FLOOR/ROOF OPENINGS, WHICH WILL AFFECT THE LOCATION OF JOISTS AND BEAMS.

    7. CONTRACTOR TO ADVISE "MANUFACTURERS" OF ANY MODIFICATIONS AND/OR CHANGES TO THIS JOIST AND BEAMPLACEMENT GUIDE.

    8. JOISTS SHALL BE ERECTED AND FASTENED IN A STRAIGHT AND PLUMB POSITION.9. DO NOT CUT, DRILL, OR NOTCH THE TOP OR BOTTOM CHORD OF THE JOISTS.

    10. DO NOT CUT, DRILL, OR NOTCH BEAMS.11. FIELD BRACING IS NOT THE RESPONSIBILITY OF THE "TRIFORCE" FABRICATOR, SUPPLIER, OR DESIGNER. FIELD

    PERSONEL ERECTING JOISTS ARE CAUTIONED TO SEEK PROFFESIONAL ADVICE REGARDING TEMPORARY ERECTIONBRACING WHICH IS "ALWAYS REQUIRED" TO PREVENT TOPPLING AND DOMINOING IN SPECIFIC APPLICATIONS.

    12. WHERE NO DIRECT TOP CHORD SHEATHING IS DIRECTLY APPLIED, JOISTS MUST BE BRACED AT 2'-0" O.C. MAXIMUM.WHERE NO BOTTOM CHORD SHEATHING IS DIRECTLY APPLIED, JOISTS MUST BE BRACED AT 10'-0" O.C. MAXIMUM.

    13. ALL JOISTS AND LVL BEAMS MUST BE USED IN A DRY ENVIROMENT AND PROTECTED FROM MOISTURE.14. JOISTS MUST BE HANDLED WITH EXTREME CARE DURING ERECTION TO PREVENT DAMAGE OR PERSONAL INJURY.

    REFER TO JOIST ENGINEERING FOR CONNECTION AND BRACING REQUIRMENTS. THESE CALCULATIONS ARESUPPLIED FOR THE ENGINEER OF RECORD TO ADEQUATELY PROVIDE FOR CONNECTION AND INTEGRATION OF THEROOF ASSEMBLY TO THE SUPPORTING STRUCTURE. DESIGNERS OF SUPPORTING CONNECTIONS ARE "SOLEY"RESPONSIBLE FOR THE INTEGRITY OF THEIR PRODUCT(S).

    15. ALL JOIST AND BEAMS MUST HAVE FULL BEARING CONTACT IN HANGERS. ALL JOIST AND LVL HANGERS TO BEFASTENED AS PER "SIMPSON STRONG TIE" SPECIFICATIONS FOR MAXIMUM RESISTANCE.

    16. WHEN TILE IS INSTALLED AS AN OPTION ON SECOND STORY APPLICATIONS. A L/600 DEFLECTION CRITERIA OR 16" ONCENTER SPACING WILL BE NECESSARY TO MAINTAIN TILE WARRANTY.

    17. WHERE BEAMS ARE NOT THE SAME DEPTH AS THE JOISTS, LOCATE THE BEAM AT THE SAME ELEVATION AS THE TOPOF THE JOISTS. BUILD UP WALL AT BEARING POINTS OR BUILD UP BEAM WITH A COMBINATION OF 2X'S ANDPLYWOOD.

    18. THE FOLLOWING PRODUCT EVALUATIONS, ISSUED FOR "TRIFORCE" ARERECOGNIZED BY BOCA, IBC, IRC, SBC, AND UBCREPORT NO. ESR-2999"TRIFORCE" IS A MEMBER OF THE WOOD TRUSS COUNCIL OF AMERICATHIRD PARTY CERTIFICATION: INTERTEK TESTING SERVICES, WHICH USES THE WARNOCK HERSEY CERTIFICATIONMARK FOR ENGINEERED WOOD PRODUCTS IS THE INDEPENDENT EVALUATION/TESTING AGENCY FOR CERTIFICATIONOF "TRIFORCE" MANUFACTURING PROCESS.

    19. WHEN SPECIFIC GRAVITY (DENSITY) IN SEISMIC ZONES IS SPECIFIED .05, SPF 2400 MSR WILL NEED TO BE SPECIFIEDFOR ALL LENGTHS. PLEASE VERIFY WITH ENGINEER OF RECORD AND/OR LOCAL MUNICIPALITY.

    20. MINIMUM BEAM SPECIFICATIONS FOR SUBSTITUTION SHOULD BE AS FOLLOWS MOE-2.0E6 PSI, FB 2800 PSI, AND FV285 PSI. VERIFY WITH ENGINEER OF RECORD FOR VARIANCE.

    21. ALL INTERIOR WALLS ARE ASSUMED TO BE NON LOAD BEARING UNLESS NOTED OTHERWISE. ALL LOADS AREASSUMED TO BE TRANSFERRED TO WALLS OR COLUMNS THAT STACK ALL THE WAY DOWN TO THE FOUNDATION. IFTHIS IS NOT THE CASE, ADDITIONAL MATERIAL WILL BE REQUIRED!!!

    22. JOIST PLACEMENT GUIDES AND ENGINEERING MAY NOT BE REPRODUCED IN PART OR IN FULL UNDER ANYCIRCUMSTANCES.

    OPEN JOIST TRIFORCE® and OPEN JOIST 2000® are in accordance with ICC 2009 and NDS-2010. OPEN JOIST TRIFORCE® and OPEN JOIST 2000® have been evaluated by ICC (report # ESR-2999) & (report # ESR-1035) and are quality controlled by a qualified third

    party agency. Parts are joined together with phenol-resorcinol adhesives. Lumber used for diagonal and vertical web members is visually graded in-plant as per quality control manual. A sub-floor must be attached to the top chord member according to the building code. If

    specified, strong backs must be of dry lumber and attached to the joists, according to current practice. Required bearing length must be determined for each application based on specifications by the manufacturer and must never be less than 1.5 inches. OPEN JOIST 2000®

    must be used under dry conditions. Refer to the specifications by the manufacturer for details of installation

    FOR QUOTE ONLY! NOT FOR CONSTRUCTION!

    FLOOR/LEVEL NAME1st Level

    Qui

    ckTo

    ols

    5.4.

    1211

    .0

    Reviewed For Code Compliance

  • ALL INTERIOR WALLS ARE ASSUMED NON-LOAD BEARING UNLESS OTHERWISE NOTED.

    FULL DEPTH BLOCKING

    FULL DEPTH BLOCKING

    FULL DEPTH BLOCKING

    FULL

    DEP

    TH

    BLO

    CKIN

    G

    FULL DEPTH BLOCKING

    6

    N2P

    2

    N2P

    6

    6

    N2P

    6

    6

    16" O.C.SpacingStart

    9'-0

    "

    10'-8"

    10'-0"

    J12

    J15

    4'-0

    "

    2'-6"

    12'-8

    "

    20'-8"

    22'-2 1/4"

    J19

    J17

    J1

    J15

    J16

    J12J17

    J10J12J

    14

    20'-0"

    5'-10"12'-8"

    2'-6

    "

    4'-7 1

    /4"

    1'-8

    "

    30'-8

    "

    18'-8

    "

    10'-0

    "

    8'-4"

    32'-0"

    6'-4

    "10

    '-2"

    5'-6

    "

    32'-4"

    2'-6

    "

    6'-4

    "

    19'-6 1/16"

    2'-0"

    5'-8

    "

    J13

    J14

    J13

    J1

    J1

    J16

    J12

    J15

    J10

    J15

    J1

    J21

    J14J14

    J2

    J13

    J1

    J15

    J16

    J14

    J10

    J12

    J1J1

    5

    Rim

    boar

    d

    Rim

    boar

    d

    Rimboard

    Rimboard

    Rimb

    oard

    Rim

    boar

    d

    RimboardRimboard

    Rimboard

    Rimboard

    Rim

    boar

    d

    Rim

    boar

    d

    Rim

    boar

    d

    Rim

    boar

    d

    Rimboard

    Rimboard

    Rim

    boar

    d

    Rim

    boar

    d

    Rimboard

    Rimboard

    Rimboard

    Rim

    boar

    d

    Rim

    boar

    d

    Rimbo

    ard

    Rimboard

    Rimboard

    Rim

    boar

    d

    Rimboard

    Rimboard

    Rim

    boar

    d

    H1

    TUL: 2890TUL: 2890

    H1

    TUL: 2890TUL: 2890

    G15

    G12

    G14

    G27

    G20

    G21

    G34

    G19

    G7

    G18

    G7

    G22

    G13

    G20

    Continuous Strongback 2 X 10

    Continuous Strongback 2 X 10

    Continuous Strongback 2 X 10

    Continuous Strongback 2 X 10

    Continuous Strongback 2 X 10

    Continuous Strongback 2 X 10

    Continuous Strongback 2 X 10

    C85TUL: 335.2

    C67TUL: 0

    TUL: 4556

    TUL: 954

    C69TUL: 0

    C136TUL: 0

    C68TUL: 1850.7

    TUL: 4505.8

    C81TUL: 0

    C70TUL: 0

    C62TUL: 0 C135

    TUL: 0

    C134TUL: 0

    TUL: 6339.2

    TUL: 1419.5

    TUL: 7282.2

    TUL: 4222.5 C132TUL: 0

    C124TUL: 1521.9

    TUL: 2281.8

    TUL: 422.7

    C128TUL: 0

    C64TUL: 941.6

    C139TUL: 0

    TUL: 7558.4

    TUL: 990.2

    Start Joist Run

    ENGINEERINGDesign Method ASD

    Floor LoadsLive 40 PSFDead 15 PSFConstruction 0 PSF

    Floor DeflectionLL Girder L/360LL Joist L/480DL Girder L/360DL Joist L/360TL Girder L/240TL Joist L/240

    Floor Deck and VibrationDeck: 3/4" SPF Plywood, Nailed & GluedCeiling: NoneStrapping: no strapping

    NOTES1. THIS JOIST PLACEMENT GUIDE IS FOR "TRIFORCE" PRODUCTS ONLY.2. THIS JOIST PLACEMENT GUIDE SHOULD BE REVIEWED BY THE ARCHITECT, ENGINEER OF RECORD OR BUILDER TO

    ENSURE THAT NO ADDITIONAL ROOF LOADS WILL BE TRANSFERRED ONTO THE FLOOR SYSTEM AND THAT THEFOUNDATION DESIGN ACCOUNTS FOR ALL LOADS.

    3. THIS JOIST PLACMENT GUIDE IS PROVIDED FOR THE SOLE PURPOSE OF MATERIAL REFERENCE ONLY. THE BUILDINGDESIGNER AND/OR PROJECT COORDINATOR IS THE PROJECTS SOLE REPSONSIBLE PARTY AND ALL SPANS,LOCATIONS, LOADING FOR JOISTS, BEAMS, LENGTHS AND QUANTITIES SHOULD BE VERIFIED PRIOR TO ORDERING.

    4. THIS JOIST PLACEMENT GUIDE MAY HAVE BEEN DESIGNED WITH OR WITHOUT FULL STRUCTURAL PLANS ANDSHOULD BE REVIEWED BY THE ARCHITECT AND/OR THE ENGINEER OF RECORD TO ENSURE STRUCTURAL INTEGRITY."TRIFORCE" CAN NOT BE REPSPONSIBLE FOR FIELD FRAMING AND BRACING LOCATIONS NOT SPECIFIED ON THEORIGINAL PLANS. THE PROJECTS SOLE RESPONSIBLE PARTY IS TO TRANSFER ALL ROOF LOADS TO FOUNDATIONS.

    5. ALL "TRIFORCE" PRODUCTS DETAILS APPLY TO ALL REVELANT OCCURENCES WHETHER OR NOT THEY ARESPECIFICALLY INDICATED ON THE PLACEMENT GUIDE.

    6. CONTRACTOR TO COORDINATE WITH MECHANICAL, ELECTRICAL, AND ARCHITECTURAL DRAWINGS FOR THELOCATIONS AND SIZES OF FLOOR/ROOF OPENINGS, WHICH WILL AFFECT THE LOCATION OF JOISTS AND BEAMS.

    7. CONTRACTOR TO ADVISE "MANUFACTURERS" OF ANY MODIFICATIONS AND/OR CHANGES TO THIS JOIST AND BEAMPLACEMENT GUIDE.

    8. JOISTS SHALL BE ERECTED AND FASTENED IN A STRAIGHT AND PLUMB POSITION.9. DO NOT CUT, DRILL, OR NOTCH THE TOP OR BOTTOM CHORD OF THE JOISTS.

    10. DO NOT CUT, DRILL, OR NOTCH BEAMS.11. FIELD BRACING IS NOT THE RESPONSIBILITY OF THE "TRIFORCE" FABRICATOR, SUPPLIER, OR DESIGNER. FIELD

    PERSONEL ERECTING JOISTS ARE CAUTIONED TO SEEK PROFFESIONAL ADVICE REGARDING TEMPORARY ERECTIONBRACING WHICH IS "ALWAYS REQUIRED" TO PREVENT TOPPLING AND DOMINOING IN SPECIFIC APPLICATIONS.

    12. WHERE NO DIRECT TOP CHORD SHEATHING IS DIRECTLY APPLIED, JOISTS MUST BE BRACED AT 2'-0" O.C. MAXIMUM.WHERE NO BOTTOM CHORD SHEATHING IS DIRECTLY APPLIED, JOISTS MUST BE BRACED AT 10'-0" O.C. MAXIMUM.

    13. ALL JOISTS AND LVL BEAMS MUST BE USED IN A DRY ENVIROMENT AND PROTECTED FROM MOISTURE.14. JOISTS MUST BE HANDLED WITH EXTREME CARE DURING ERECTION TO PREVENT DAMAGE OR PERSONAL INJURY.

    REFER TO JOIST ENGINEERING FOR CONNECTION AND BRACING REQUIRMENTS. THESE CALCULATIONS ARESUPPLIED FOR THE ENGINEER OF RECORD TO ADEQUATELY PROVIDE FOR CONNECTION AND INTEGRATION OF THEROOF ASSEMBLY TO THE SUPPORTING STRUCTURE. DESIGNERS OF SUPPORTING CONNECTIONS ARE "SOLEY"RESPONSIBLE FOR THE INTEGRITY OF THEIR PRODUCT(S).

    15. ALL JOIST AND BEAMS MUST HAVE FULL BEARING CONTACT IN HANGERS. ALL JOIST AND LVL HANGERS TO BEFASTENED AS PER "SIMPSON STRONG TIE" SPECIFICATIONS FOR MAXIMUM RESISTANCE.

    16. WHEN TILE IS INSTALLED AS AN OPTION ON SECOND STORY APPLICATIONS. A L/600 DEFLECTION CRITERIA OR 16" ONCENTER SPACING WILL BE NECESSARY TO MAINTAIN TILE WARRANTY.

    17. WHERE BEAMS ARE NOT THE SAME DEPTH AS THE JOISTS, LOCATE THE BEAM AT THE SAME ELEVATION AS THE TOPOF THE JOISTS. BUILD UP WALL AT BEARING POINTS OR BUILD UP BEAM WITH A COMBINATION OF 2X'S ANDPLYWOOD.

    18. THE FOLLOWING PRODUCT EVALUATIONS, ISSUED FOR "TRIFORCE" ARERECOGNIZED BY BOCA, IBC, IRC, SBC, AND UBCREPORT NO. ESR-2999"TRIFORCE" IS A MEMBER OF THE WOOD TRUSS COUNCIL OF AMERICATHIRD PARTY CERTIFICATION: INTERTEK TESTING SERVICES, WHICH USES THE WARNOCK HERSEY CERTIFICATIONMARK FOR ENGINEERED WOOD PRODUCTS IS THE INDEPENDENT EVALUATION/TESTING AGENCY FOR CERTIFICATIONOF "TRIFORCE" MANUFACTURING PROCESS.

    19. WHEN SPECIFIC GRAVITY (DENSITY) IN SEISMIC ZONES IS SPECIFIED .05, SPF 2400 MSR WILL NEED TO BE SPECIFIEDFOR ALL LENGTHS. PLEASE VERIFY WITH ENGINEER OF RECORD AND/OR LOCAL MUNICIPALITY.

    20. MINIMUM BEAM SPECIFICATIONS FOR SUBSTITUTION SHOULD BE AS FOLLOWS MOE-2.0E6 PSI, FB 2800 PSI, AND FV285 PSI. VERIFY WITH ENGINEER OF RECORD FOR VARIANCE.

    21. ALL INTERIOR WALLS ARE ASSUMED TO BE NON LOAD BEARING UNLESS NOTED OTHERWISE. ALL LOADS AREASSUMED TO BE TRANSFERRED TO WALLS OR COLUMNS THAT STACK ALL THE WAY DOWN TO THE FOUNDATION. IFTHIS IS NOT THE CASE, ADDITIONAL MATERIAL WILL BE REQUIRED!!!

    22. JOIST PLACEMENT GUIDES AND ENGINEERING MAY NOT BE REPRODUCED IN PART OR IN FULL UNDER ANYCIRCUMSTANCES.

    OPEN JOIST TRIFORCE® and OPEN JOIST 2000® are in accordance with ICC 2009 and NDS-2010. OPEN JOIST TRIFORCE® and OPEN JOIST 2000® have been evaluated by ICC (report # ESR-2999) & (report # ESR-1035) and are quality controlled by a qualified third

    party agency. Parts are joined together with phenol-resorcinol adhesives. Lumber used for diagonal and vertical web members is visually graded in-plant as per quality control manual. A sub-floor must be attached to the top chord member according to the building code. If

    specified, strong backs must be of dry lumber and attached to the joists, according to current practice. Required bearing length must be determined for each application based on specifications by the manufacturer and must never be less than 1.5 inches. OPEN JOIST 2000®

    must be used under dry conditions. Refer to the specifications by the manufacturer for details of installation

    PROJECT/JOB NUMBERUSLR0029CUSTOMER NAMEUS LUMBERCREATED DATE9/3/2015 2:15:10 PM

    DRAWN BYEWP

    JOB NAMECILIBERTO RESIDENCE

    FLOOR/LEVEL NAME2nd Level

    FOR QUOTE ONLY! NOT FOR CONSTRUCTION!JOIST SCHEDULE

    LABEL QTY DESCRIPTION PLIES R/LENJ2 1 NI-60 16 1 4'J13 3 NI-60 16 1 3'

    Total length: 13'J16 9 OJ-314 16 1 8'J14 29 OJ-314 16 1 14'J15 8 OJ-314 16 1 10'J1 7 OJ-314 16 1 6'J10 26 OJ-314 16 1 12'J12 35 OJ-314 16 1 16'

    Total length: 1472'J19 1 OJ-315 16 2 20'J19 19 OJ-315 16 1 20'J17 9 OJ-315 16 1 18'

    Total length: 582'J21 24 OJ-418 16 1 24'

    Total length: 576'RIM BOARD SCHEDULE

    QTY DESCRIPTION R/LEN22x16' board(s) APA Rimboard 16 / 1.125 352

    LAYOUT/MODEL NAME

    USLR0029S1_Rev2

    See your local building code in effect forminimal bottom chord bracing.

    WARNING FOR A PROPER INSTALLATION(TOP AND

    BOTTOM)Please refer to the stamp on the joist to

    install them in the right position

    LVL SCHEDULELABEL QTY DESCRIPTION PLIES R/LENH1 2 PW LVL-2.0E 1.75 X 11.875 2 10'

    Total length: 40'G18 1 PW LVL-2.0E 1.75 X 16 2 7'G22 1 PW LVL-2.0E 1.75 X 16 2 13'G7 2 PW LVL-2.0E 1.75 X 16 2 5'G15 1 PW LVL-2.0E 1.75 X 16 3 20'G12 1 PW LVL-2.0E 1.75 X 16 2 6'G13 1 PW LVL-2.0E 1.75 X 16 2 14'G14 1 PW LVL-2.0E 1.75 X 16 2 18'

    Total length: 196'

    ReinforcementFor reinforcement please refer to the

    calculation sheets

    HANGER SCHEDULELVL/JOIST QTY DESCRIPTIONG34 1 CUSTOM HUS212-2G20 1 CUSTOM HUSR/L410J12 2 CUSTOM SUR/L2.56/16J15 1 CUSTOM SUR/L2.56/16J17 1 CUSTOM SUR/L2.56/16J14 1 CUSTOM SUR/L2.56/16J16 1 CUSTOM SUR/L2.56/16J1 1 CUSTOM SUR/L2.56/16J10 2 CUSTOM SUR/L2.56/16J19 1 CUSTOM SUR/L2.56/16G22 1 Simpson HGUS414 16G12 1 Simpson HGUS414 16J19 2 Simpson IUS2.56/16 16J17 1 Simpson IUS2.56/16 16J16 8 Simpson IUS2.56/16 16J15 3 Simpson IUS2.56/16 16J10 19 Simpson IUS2.56/16 16J1 4 Simpson IUS2.56/16 16J12 10 Simpson IUS2.56/16 16J14 29 Simpson IUS2.56/16 16J13 1 Simpson MIU2.56/16 16J2 1 Simpson MIU2.56/16 16

    BLOCKING SCHEDULEDESCRIPTION TOT. LIN. FT.NI-60 2.5 X 16 64

    Continuous StrongbackDESCRIPTION TOT. LIN. FT.Continuous Strongback 2 X 10 254

    Qui

    ckTo

    ols

    5.4.

    1211

    .0

    Reviewed For Code Compliance

  • F19

    F19

    F19

    SCALE: 1/4" = 1'

    CEILING FRAMING

    ALL 2X DIMENSIONAL LUMBER

    PROVIDED BY OTHERS

    ALL CEILING JOIST

    TO BE A MINIMUM

    2X8 SPF #2 @ 16"

    O/C (U.N.O)

    ( 4 ) J3 @ 6' J3

    2 X J6

    ( 7 ) J8 @ 16'

    3 X J8

    J7

    2 X J6

    J5

    2 X J2

    J1

    ( 14 ) J8 @ 16'

    ( 9 ) J7 @ 14'( 7 ) J7 @ 14'3 X J7

    ( 9 ) J4 @ 8'

    ( 8 ) J7 @ 14'

    3 X

    J4

    3 X

    J5

    ( 5 )

    J5 @

    10'

    2 X

    J5

    J5

    FB10 ( 2 ply )

    FB

    9 (

    2 p

    ly )

    FB

    9 (

    2 p

    ly )

    FB

    9 (

    2 p

    ly )

    FB8

    ( 2 p

    ly )

    FB8

    ( 2 p

    ly )

    FB

    8 (

    2 p

    ly )

    FB7 ( 2 ply )

    FB7 ( 2 ply )

    FB6 ( 2 ply )

    FB

    6 (

    2 p

    ly )

    FB

    5 (

    2 p

    ly )

    FB14 ( 2 ply )

    FB

    3 (

    2 p

    ly )

    DB

    1 (

    2 p

    ly )

    FB

    16 (

    3 p

    ly )

    FB

    16 (

    3 p

    ly )

    FB

    15 (

    3 p

    ly )

    FB

    15 (

    3 p

    ly )

    FB12 ( 3 ply )

    FB

    12 (

    3 p

    ly )

    FB2

    ( 2 p

    ly )

    FB1 ( 2 ply )

    FB13 ( 2 ply )

    FB

    11 (

    3 p

    ly )

    FB17

    ( 3

    ply

    )

    FB

    17 (

    3 p

    ly )

    PS

    PS

    PS

    H1

    H1

    H1

    H1

    H1

    H1

    H1H

    1H

    1

    H1

    Ceiling Framing

    LVL (Flush)

    Label Description Width Depth Qty Plies Pcs Length

    FB3 GP Lam 2.0E LVL 1.75 9.25 1 2 2 18-0-0

    FB14 GP Lam 2.0E LVL 1.75 11.875 1 2 2 16-0-0

    Lumber (Flush)

    Label Description Width Depth Qty Plies Pcs Length

    J1 S-P-F #2 1.5 7.25 1 2-0-0

    J2 S-P-F #2 1.5 7.25 2 4-0-0

    J3 S-P-F #2 1.5 7.25 5 6-0-0

    J4 S-P-F #2 1.5 7.25 12 8-0-0

    J5 S-P-F #2 1.5 7.25 12 10-0-0

    J6 S-P-F #2 1.5 7.25 4 12-0-0

    J7 S-P-F #2 1.5 7.25 28 14-0-0

    J8 S-P-F #2 1.5 7.25 24 16-0-0

    FB1 S-P-F #2 1.5 7.25 2 10-0-0

    FB2 S-P-F #2 1.5 7.25 2 12-0-0

    FB5 SYP #2 1.5 9.25 2 6-0-0

    FB6 SYP #2 1.5 9.25 4 10-0-0

    FB7 SYP #2 1.5 9.25 4 12-0-0

    FB8 SYP #2 1.5 9.25 6 14-0-0

    FB9 SYP #2 1.5 9.25 6 16-0-0

    FB10 SYP #2 1.5 9.25 2 20-0-0

    FB12 SYP #2 1.5 9.25 6 12-0-0

    FB15 SYP #2 1.5 9.25 6 14-0-0

    FB16 SYP #2 1.5 9.25 6 16-0-0

    FB11 SYP #2 1.5 11.25 3 24-0-0

    FB13 SYP #2 1.5 11.25 2 12-0-0

    FB17 SYP #2 1.5 11.25 6 16-0-0

    Lumber (Dropped)

    Label Description Width Depth Qty Plies Pcs Length

    DB1 SYP #2 1.5 9.25 2 12-0-0

    LegendPS

    Point Load Support

    Load from Above

    4" EXT

    4" NON

    4" INT

    3.5" EXT

    GP Lam 2.0E LVL 1.75 X 9.25

    GP Lam 2.0E LVL 1.75 X 11.875

    S-P-F #2 1.5 X 7.25

    SYP #2 1.5 X 9.25

    SYP #2 1.5 X 9.25 (Dropped)

    SYP #2 1.5 X 11.25

    Ceiling Framing Design Method ASD

    Building Code IBC/IRC

    FloorLoads

    Live 20

    Dead 10

    Deflection Joist

    LL Span L/ 480

    TL Span L/ 240

    LL Cant L/ 180

    TL Cant L/ 180

    Deflection Girder

    LL Span L/ 360

    TL Span L/ 240

    LL Cant L/ 180

    TL Cant L/ 180

    Decking

    Deck SPF Plywood

    Fastener Nailed & Glued

    Thickness 23/32"

    FastPlan Notes:

    GP Lam LVL, GPI, WI, GP GluLam, and FiberStrong Rim Board are registered trademarks of Georgia-Pacific Wood Products LLC.

    Specified products are sized for gravity loads only. Prior to installation, review these layouts with the project designer or engineer of record.

    For additional Georgia-Pacific installation details and information please refer to our Installation Guide.

    Do not notch or cut holes in Georgia-Pacific engineered wood products outside the guidelines of the Installation Guide.

    These products were designed for “dry use” conditions only and must be protected from long term exposure to high moisture.

    WARNING: DO NOT ALLOW WORKERS ON I-JOISTS UNTIL PROPERLY BRACED.

    See Georgia Pacific Installation Guide for additional information.

    General Installation Notes:

    I Joists require 1 ¾” minimum bearing and should be nailed to bearing plate with one 10d box/sinker nail each side.

    I-joist rim and FiberStrong Rim Board should be nailed to the bearing plate with 8d nails @ 6” O.C.

    Side loaded, double I-Joists shall be packed solid and connected with 2 rows of 10d nails @ 12” O.C.

    Plumbing Conflicts: Every third joist may be shifted up to 3” to avoid plumbing.

    Deck attachment: Exterior decks may be attached to 1 1/8” FiberStrong Rim Board with ½” diameter lagscrews or thru bolts. (capacity = 350 lbs per fastener )

    Minimum multiple LVL fastening:14” depth or less 2 rows 16 d nails @ 12” O.C.16” depth and greater 3 rows 16d nails @ 12” O.C.

    ClientGuy C Lee-Shallotte

    Client Address315 Brick Landing Road SW

    Shallotte, NC

    28459

    Project201601-5410

    CreatedJanuary 11, 2016

    Layout NameCiliberto Res REV

    Description

    DesignerKeven Keenan

    RevisedJune 14, 2016

    3312 North Berkeley Lake Rd

    Duluth, GA 30096

    888-613-5078

    Powered by iStruct 15.8.104 This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them

    Reviewed For Code Compliance

  • 1

    ROOF FRAMINGSCALE: 1/4" = 1'

    ALL 2X DIMENSIONAL LUMBER

    PROVIDED BY OTHERS

    JOIST LABELS

    HIDEN

    FOR CLARITY

    POST PO

    ST

    POST

    POSTPOST POST

    POST

    POST

    POST

    POST

    PO

    ST

    POST

    POST

    PO

    ST

    POST

    POST

    POST

    POST

    POST

    POST

    POST

    POST

    POST

    POST

    POST

    POST

    POST

    ALL RAFTERS TO

    BE A MINIMUM

    2X8 SPF #2@ 16"

    O/C (U.N.O)

    BR

    AC

    E S

    TR

    ON

    G B

    AC

    KS

    RB16 ( 2 ply )

    RB15

    ( 2 p

    ly )

    RB14

    ( 2 p

    ly )

    RB13

    ( 2 p

    ly )

    RB13 ( 2 ply )RB12 ( 2 ply )

    RB

    12 (

    2 pl

    y )

    RB11

    ( 2 p

    ly )

    RB11 ( 2 ply )

    RB11 ( 2 ply )

    RB

    11 (

    2 p

    ly )

    RB11 ( 2 ply )

    RB10

    ( 2 p

    ly )

    RB10 ( 2 ply )

    RB10

    ( 2 p

    ly )

    RB10 ( 2 ply )

    RB9 ( 2 ply )

    RB9 ( 2 ply )

    RB

    9 ( 2

    ply

    )

    RB9 (

    2 pl

    y )

    RB9 ( 2 ply )

    RB

    9 (

    2 pl

    y )

    RB9 ( 2 ply )

    RB8 ( 2 ply )

    RB8 (

    2 pl

    y )

    RB8 (

    2 pl

    y )

    RB8 ( 2 ply )

    RB8 ( 2 ply )

    RB8 ( 2 ply )

    RB8 (

    2 pl

    y )

    RB8 ( 2 ply )RB7 ( 2 ply )

    RB7 ( 2 ply )

    RB7 ( 2 ply )

    RB

    7 (

    2 p

    ly )

    RB7 ( 2 ply )RB

    7 ( 2

    ply )

    RB7 (

    2 pl

    y )

    RB7 ( 2 ply )

    RB6 (

    2 pl

    y )

    RB

    6 (

    2 p

    ly )

    RB6 ( 2 ply )

    RB6 (

    2 pl

    y )RB6 ( 2 ply )

    RB5 ( 2 ply )

    RB4 ( 2 ply )

    RB

    4 (

    2 p

    ly )

    RB

    3 (

    1 pl

    y )

    RB17 ( 1 ply )

    RB17

    ( 1 p

    ly )

    RB2 (

    1 pl

    y )RB2 ( 1 ply )

    RB2 (

    1 pl

    y )

    RB2 ( 1 ply )

    RB1 ( 1 ply )

    Roof Framing

    Lumber (Flush)

    Label Description Width Depth Qty Plies Pcs Length

    RB1 SYP #2 1.5 9.25 1 8-0-0

    RB2 SYP #2 1.5 9.25 4 10-0-0

    RB3 SYP #2 1.5 9.25 1 18-0-0

    RB17 SYP #2 1.5 9.25 2 12-0-0

    Lumber (Dropped)

    Label Description Width Depth Qty Plies Pcs Length

    RJ1 S-P-F #2 1.5 7.25 4 2-0-0

    RJ2 S-P-F #2 1.5 7.25 53 4-0-0

    RJ3 S-P-F #2 1.5 7.25 83 6-0-0

    RJ4 S-P-F #2 1.5 7.25 71 8-0-0

    RJ5 S-P-F #2 1.5 7.25 57 10-0-0

    RJ6 S-P-F #2 1.5 7.25 71 12-0-0

    RJ7 S-P-F #2 1.5 7.25 35 14-0-0

    RJ8 S-P-F #2 1.5 7.25 7 22-0-0

    RJ9 S-P-F #2 1.5 7.25 21 16-0-0

    RJ10 S-P-F #2 1.5 7.25 38 18-0-0

    RJ11 S-P-F #2 1.5 7.25 10 20-0-0

    RJ12 S-P-F #2 1.5 7.25 7 24-0-0

    RB4 SYP #2 1.5 9.25 4 4-0-0

    RB5 SYP #2 1.5 9.25 2 6-0-0

    RB6 SYP #2 1.5 9.25 10 8-0-0

    RB7 SYP #2 1.5 9.25 16 10-0-0

    RB8 SYP #2 1.5 9.25 16 12-0-0

    RB9 SYP #2 1.5 9.25 14 14-0-0

    RB10 SYP #2 1.5 9.25 8 16-0-0

    RB11 SYP #2 1.5 9.25 10 18-0-0

    RB12 SYP #2 1.5 9.25 4 22-0-0

    RB13 SYP #2 1.5 9.25 4 24-0-0

    RB14 SYP #2 1.5 9.25 2 26-0-0

    RB15 SYP #2 1.5 9.25 2 28-0-0

    L1 SYP #2 1.5 11.25 1 14-0-0

    RB16 SYP #2 1.5 11.25 2 32-0-0

    LegendPS

    Point Load Support

    Load from Above

    4" EXT

    4" NON

    4" INT

    3.5" EXT

    S-P-F #2 1.5 X 7.25

    SYP #2 1.5 X 9.25 (Dropped)

    SYP #2 1.5 X 9.25

    SYP #2 1.5 X 11.25 (Dropped)

    SYP #2 1.5 X 11.25

    Roof FramingDesign Method ASD

    Building Code IBC/IRC

    RoofLoads

    Live 0

    Dead 10

    Construction 16

    Deflection Joist

    LL Span L/ 480

    TL Span L/ 240

    LL Cant L/ 180

    TL Cant L/ 180

    Deflection Girder

    LL Span L/ 360

    TL Span L/ 240

    LL Cant L/ 180

    TL Cant L/ 180

    Decking

    Deck SPF Plywood

    Fastener Nailed & Glued

    Thickness 5/8"

    FastPlan Notes:

    GP Lam LVL, GPI, WI, GP GluLam, and FiberStrong Rim Board are registered trademarks of Georgia-Pacific Wood Products LLC.

    Specified products are sized for gravity loads only. Prior to installation, review these layouts with the project designer or engineer of record.

    For additional Georgia-Pacific installation details and information please refer to our Installation Guide.

    Do not notch or cut holes in Georgia-Pacific engineered wood products outside the guidelines of the Installation Guide.

    These products were designed for “dry use” conditions only and must be protected from long term exposure to high moisture.

    WARNING: DO NOT ALLOW WORKERS ON I-JOISTS UNTIL PROPERLY BRACED.

    See Georgia Pacific Installation Guide for additional information.

    General Installation Notes:

    I Joists require 1 ¾” minimum bearing and should be nailed to bearing plate with one 10d box/sinker nail each side.

    I-joist rim and FiberStrong Rim Board should be nailed to the bearing plate with 8d nails @ 6” O.C.

    Side loaded, double I-Joists shall be packed solid and connected with 2 rows of 10d nails @ 12” O.C.

    Plumbing Conflicts: Every third joist may be shifted up to 3” to avoid plumbing.

    Deck attachment: Exterior decks may be attached to 1 1/8” FiberStrong Rim Board with ½” diameter lagscrews or thru bolts. (capacity = 350 lbs per fastener )

    Minimum multiple LVL fastening:14” depth or less 2 rows 16 d nails @ 12” O.C.16” depth and greater 3 rows 16d nails @ 12” O.C.

    ClientGuy C Lee-Shallotte

    Client Address315 Brick Landing Road SW

    Shallotte, NC

    28459

    Project201601-5410

    CreatedJanuary 11, 2016

    Layout NameCiliberto Res REV

    Description

    DesignerKeven Keenan

    RevisedJune 14, 2016

    3312 North Berkeley Lake Rd

    Duluth, GA 30096

    888-613-5078

    Powered by iStruct 15.8.104 This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them

    Reviewed For Code Compliance

    Ciliberto Structural Plans 1st and 2nd Floor 9-3-15Ciliberto Structural Plans 6-23-16