606 Singapore: +65 6779 9091 [email protected] USA: +1 330 486 0001 [email protected] Germany: +49 621 776-4411 [email protected] Pepperl+Fuchs Group www.pepperl-fuchs.com Subject to modifications without notice Copyright Pepperl+Fuchs Photoelectric Sensors Photoelectric MHP Series Miniature MHP-DR33L MHP-D33L MHP-D2AL MHP-DR33Q MHP-D33Q MHP-D2AQ Sensitivity adjustment Detection range 0 ... 150 mm adjustable 0 ... 450 mm adjustable Light source IRED LED Light type modulated infrared light modulated visible red light Function display LED red and LED green Controls rotary switch for light/dark, sensitivity adjuster Operating voltage 10 ... 30 V DC 20 - 260 V AC, 50 - 60 Hz No-load supply current 1.5 mA 35 mA Operating current 250 mA max. NPN ; 150 mA max. PNP 5 ... 500 mA, up to 50 °C, derated to 300 mA at 70 °C Product standard EN 60947-5-2:2007 IEC 60947-5-2:2007 Signal output Thyristor 1 NPN and 1 PNP Voltage drop 1 V DC (NPN). 2 V DC (PNP). 6.7 V Off-state current 10 A 1.8 mA Switching frequency 500 Hz 60 Hz Response time 1 ms 8 ms Ambient temperature -30 ... 70 °C (-22 ... 158 °F) Protection degree IP69K Connection 2 m fixed cable , PVC 3 m fixed cable , PVC connector M12 x 1, 4-pin Micro AC connector, 1/2" ; 3-pin Housing Polysulphone Optical face Polycarbonate Mass approx. 130 g approx. 159 g approx. 43 g UL approval cULus CCC approval Products with a maximum operating voltage of 36 V do not bear a CCC marking because they do not require approval. MHP Series Miniature Sensors Rugged IP69K housing withstands harsh environments and high-pressure washdown areas • Adjustable sensing range DC model / AC model Visible red light source / Infrared light source Connector or cable connection Technical Specifications Diffuse Mode Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

e MHP Series Miniatur - Steven Engineering · 2011. 6. 21. · MHP Series Miniatur e Wiring Diagrams DC AC DC AC Note: Wiring diagrams show quick disconnect pin numbers. Cable Connection

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

  • 606 Singapore: +65 6779 [email protected]: +1 330 486 [email protected] Germany: +49 621 [email protected]+Fuchs Groupwww.pepperl-fuchs.comSubject to modifications without notice Copyright Pepperl+Fuchs

    Photoelectric Sensors

    Phot

    oele

    ctric

    MH

    P Se

    ries

    Min

    iatu

    re

    • Rugged IP69K housing withstands harsh environments and high-pressure washdown areas• Adjustable sensing range• DC model / AC model• Visible red light source / Infrared light source• Connector or cable connection

    MH

    P-D

    R33

    L

    MH

    P-D

    33L

    MH

    P-D

    2AL

    MH

    P-D

    R33

    Q

    MH

    P-D

    33Q

    MH

    P-D

    2AQ

    Sensitivity adjustment ● ● ● ● ● ●Detection range 0 ... 150 mm adjustable ● ●

    0 ... 450 mm adjustable ● ● ● ●Light source IRED ● ● ● ●

    LED ● ●Light type modulated infrared light ● ● ● ●

    modulated visible red light ● ●Function display LED red and LED green ● ● ● ● ● ●Controls rotary switch for light/dark, sensitivity adjuster ● ● ● ● ● ●Operating voltage 10 ... 30 V DC ● ● ● ●

    20 - 260 V AC, 50 - 60 Hz ● ●No-load supply current 1.5 mA ● ●

    35 mA ● ● ● ●Operating current 250 mA max. NPN ; 150 mA max. PNP ● ● ● ●

    5 ... 500 mA, up to 50 °C, derated to 300 mA at 70 °C ● ●Product standard EN 60947-5-2:2007

    IEC 60947-5-2:2007 ● ● ● ● ● ●

    Signal output Thyristor ● ●1 NPN and 1 PNP ● ● ● ●

    Voltage drop 1 V DC (NPN). 2 V DC (PNP). ● ● ● ● 6.7 V ● ●

    Off-state current 10 A ● ● ● ●1.8 mA ● ●

    Switching frequency 500 Hz ● ● ● ●60 Hz ● ●

    Response time 1 ms ● ● ● ● 8 ms ● ●

    Ambient temperature -30 ... 70 °C (-22 ... 158 °F) ● ● ● ● ● ●Protection degree IP69K ● ● ● ● ● ●Connection 2 m fixed cable , PVC ● ●

    3 m fixed cable , PVC ●connector M12 x 1, 4-pin ● ●Micro AC connector, 1/2" ; 3-pin ●

    Housing Polysulphone ● ● ● ● ● ●Optical face Polycarbonate ● ● ● ● ● ●Mass approx. 130 g ● ●

    approx. 159 g ●approx. 43 g ● ● ●

    UL approval cULus ● ● ● ● ● ●CCC approval Products with a maximum operating voltage of 36 V do not bear a

    CCC marking because they do not require approval. ● ● ● ●

    Photographs

    Diagrams

    Distance X [mm]

    Offset Y [mm]

    Characteristic response curve

    -10-20-30-40

    010203040

    0 100 200 300 400 500X

    Y Distance X [mm]

    Stability controlRelative received light strength

    X

    0 150 300 450 600 7501

    8

    16

    24

    32

    4044

    • Rugged IP69K housing withstands harsh environments and high-pressure washdown areas• Adjustable sensing range• DC model / AC model• Visible red light source / Infrared light source• Connector or cable connection

    MH

    P-D

    R33

    L

    MH

    P-D

    33L

    MH

    P-D

    2AL

    MH

    P-D

    R33

    Q

    MH

    P-D

    33Q

    MH

    P-D

    2AQ

    Sensitivity adjustment ● ● ● ● ● ●Detection range 0 ... 150 mm adjustable ● ●

    0 ... 450 mm adjustable ● ● ● ●Light source IRED ● ● ● ●

    LED ● ●Light type modulated infrared light ● ● ● ●

    modulated visible red light ● ●Function display LED red and LED green ● ● ● ● ● ●Controls rotary switch for light/dark, sensitivity adjuster ● ● ● ● ● ●Operating voltage 10 ... 30 V DC ● ● ● ●

    20 - 260 V AC, 50 - 60 Hz ● ●No-load supply current 1.5 mA ● ●

    35 mA ● ● ● ●Operating current 250 mA max. NPN ; 150 mA max. PNP ● ● ● ●

    5 ... 500 mA, up to 50 °C, derated to 300 mA at 70 °C ● ●Product standard EN 60947-5-2:2007

    IEC 60947-5-2:2007 ● ● ● ● ● ●

    Signal output Thyristor ● ●1 NPN and 1 PNP ● ● ● ●

    Voltage drop 1 V DC (NPN). 2 V DC (PNP). ● ● ● ● 6.7 V ● ●

    Off-state current 10 A ● ● ● ●1.8 mA ● ●

    Switching frequency 500 Hz ● ● ● ●60 Hz ● ●

    Response time 1 ms ● ● ● ● 8 ms ● ●

    Ambient temperature -30 ... 70 °C (-22 ... 158 °F) ● ● ● ● ● ●Protection degree IP69K ● ● ● ● ● ●Connection 2 m fixed cable , PVC ● ●

    3 m fixed cable , PVC ●connector M12 x 1, 4-pin ● ●Micro AC connector, 1/2" ; 3-pin ●

    Housing Polysulphone ● ● ● ● ● ●Optical face Polycarbonate ● ● ● ● ● ●Mass approx. 130 g ● ●

    approx. 159 g ●approx. 43 g ● ● ●

    UL approval cULus ● ● ● ● ● ●CCC approval Products with a maximum operating voltage of 36 V do not bear a

    CCC marking because they do not require approval. ● ● ● ●

    Photographs

    Diagrams

    Distance X [mm]

    Offset Y [mm]

    Characteristic response curve

    -10-20-30-40

    010203040

    0 100 200 300 400 500X

    Y Distance X [mm]

    Stability controlRelative received light strength

    X

    0 150 300 450 600 7501

    8

    16

    24

    32

    4044

    • Rugged IP69K housing withstands harsh environments and high-pressure washdown areas• Adjustable sensing range• DC model / AC model• Visible red light source / Infrared light source• Connector or cable connection

    MH

    P-D

    R33

    L

    MH

    P-D

    33L

    MH

    P-D

    2AL

    MH

    P-D

    R33

    Q

    MH

    P-D

    33Q

    MH

    P-D

    2AQ

    Sensitivity adjustment ● ● ● ● ● ●Detection range 0 ... 150 mm adjustable ● ●

    0 ... 450 mm adjustable ● ● ● ●Light source IRED ● ● ● ●

    LED ● ●Light type modulated infrared light ● ● ● ●

    modulated visible red light ● ●Function display LED red and LED green ● ● ● ● ● ●Controls rotary switch for light/dark, sensitivity adjuster ● ● ● ● ● ●Operating voltage 10 ... 30 V DC ● ● ● ●

    20 - 260 V AC, 50 - 60 Hz ● ●No-load supply current 1.5 mA ● ●

    35 mA ● ● ● ●Operating current 250 mA max. NPN ; 150 mA max. PNP ● ● ● ●

    5 ... 500 mA, up to 50 °C, derated to 300 mA at 70 °C ● ●Product standard EN 60947-5-2:2007

    IEC 60947-5-2:2007 ● ● ● ● ● ●

    Signal output Thyristor ● ●1 NPN and 1 PNP ● ● ● ●

    Voltage drop 1 V DC (NPN). 2 V DC (PNP). ● ● ● ● 6.7 V ● ●

    Off-state current 10 A ● ● ● ●1.8 mA ● ●

    Switching frequency 500 Hz ● ● ● ●60 Hz ● ●

    Response time 1 ms ● ● ● ● 8 ms ● ●

    Ambient temperature -30 ... 70 °C (-22 ... 158 °F) ● ● ● ● ● ●Protection degree IP69K ● ● ● ● ● ●Connection 2 m fixed cable , PVC ● ●

    3 m fixed cable , PVC ●connector M12 x 1, 4-pin ● ●Micro AC connector, 1/2" ; 3-pin ●

    Housing Polysulphone ● ● ● ● ● ●Optical face Polycarbonate ● ● ● ● ● ●Mass approx. 130 g ● ●

    approx. 159 g ●approx. 43 g ● ● ●

    UL approval cULus ● ● ● ● ● ●CCC approval Products with a maximum operating voltage of 36 V do not bear a

    CCC marking because they do not require approval. ● ● ● ●

    Photographs

    Diagrams

    Distance X [mm]

    Offset Y [mm]

    Characteristic response curve

    -10-20-30-40

    010203040

    0 100 200 300 400 500X

    Y Distance X [mm]

    Stability controlRelative received light strength

    X

    0 150 300 450 600 7501

    8

    16

    24

    32

    4044

    MHP Series Miniature Sensors

    • Rugged IP69K housing withstands harsh environments and high-pressure washdown areas

    • Adjustable sensing range• DC model / AC model• Visible red light source / Infrared light

    source• Connector or cable connection

    Technical Specifications

    Diffuse Mode

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 607Singapore: +65 6779 [email protected]: +1 330 486 [email protected] Germany: +49 621 [email protected]+Fuchs Groupwww.pepperl-fuchs.comSubject to modifications without notice Copyright Pepperl+Fuchs

    Photoelectric Sensors

    Photoelectric MH

    P Series Miniature

    Wiring Diagrams

    DC DCAC AC

    Note: Wiring diagrams show quick disconnect pin numbers.

    Quick DisconnectCable Connection

    • Rugged IP69K housing withstands harsh environments and high-pressure washdown areas• Adjustable sensing range• DC model / AC model• Visible red light source / Infrared light source• Connector or cable connection

    MH

    P-D

    R33

    L

    MH

    P-D

    33L

    MH

    P-D

    2AL

    MH

    P-D

    R33

    Q

    MH

    P-D

    33Q

    MH

    P-D

    2AQ

    Sensitivity adjustment ● ● ● ● ● ●Detection range 0 ... 150 mm adjustable ● ●

    0 ... 450 mm adjustable ● ● ● ●Light source IRED ● ● ● ●

    LED ● ●Light type modulated infrared light ● ● ● ●

    modulated visible red light ● ●Function display LED red and LED green ● ● ● ● ● ●Controls rotary switch for light/dark, sensitivity adjuster ● ● ● ● ● ●Operating voltage 10 ... 30 V DC ● ● ● ●

    20 - 260 V AC, 50 - 60 Hz ● ●No-load supply current 1.5 mA ● ●

    35 mA ● ● ● ●Operating current 250 mA max. NPN ; 150 mA max. PNP ● ● ● ●

    5 ... 500 mA, up to 50 °C, derated to 300 mA at 70 °C ● ●Product standard EN 60947-5-2:2007

    IEC 60947-5-2:2007 ● ● ● ● ● ●

    Signal output Thyristor ● ●1 NPN and 1 PNP ● ● ● ●

    Voltage drop 1 V DC (NPN). 2 V DC (PNP). ● ● ● ● 6.7 V ● ●

    Off-state current 10 A ● ● ● ●1.8 mA ● ●

    Switching frequency 500 Hz ● ● ● ●60 Hz ● ●

    Response time 1 ms ● ● ● ● 8 ms ● ●

    Ambient temperature -30 ... 70 °C (-22 ... 158 °F) ● ● ● ● ● ●Protection degree IP69K ● ● ● ● ● ●Connection 2 m fixed cable , PVC ● ●

    3 m fixed cable , PVC ●connector M12 x 1, 4-pin ● ●Micro AC connector, 1/2" ; 3-pin ●

    Housing Polysulphone ● ● ● ● ● ●Optical face Polycarbonate ● ● ● ● ● ●Mass approx. 130 g ● ●

    approx. 159 g ●approx. 43 g ● ● ●

    UL approval cULus ● ● ● ● ● ●CCC approval Products with a maximum operating voltage of 36 V do not bear a

    CCC marking because they do not require approval. ● ● ● ●

    Photographs

    Diagrams

    Distance X [mm]

    Offset Y [mm]

    Characteristic response curve

    -10-20-30-40

    010203040

    0 100 200 300 400 500X

    Y Distance X [mm]

    Stability controlRelative received light strength

    X

    0 150 300 450 600 7501

    8

    16

    24

    32

    4044

    Dimensions Drawings

    Electrical Connection

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    64.8

    45.7

    49.515.315.8

    1-20 UNEF-2A

    30

    19.1

    Ø 3

    24.4

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    15.8

    30

    1-20 UNEF-2A

    Ø 3

    DC: M12 x 1AC: 1/2" - 20

    64.8

    45.7

    49.5 6.415.3

    19.1

    24.4

    MHP-DR33LMHP-D2ALMHP-D33L

    MHP-DR33QMHP-D2AQMHP-D33Q

    2

    1

    3

    4

    +UB

    Q

    0 V

    Q

    3

    1

    2

    n. c.

    L2

    L1

    WH

    BN

    BU

    BK

    +UB

    Q

    0 V

    Q

    BU

    BN L1

    L2

    MHP-DR33QMHP-D33Q

    MHP-D2AQMHP-DR33LMHP-D33L

    MHP-D2AL

    1

    2 3

    1

    3

    42

    Dimensions Drawings

    Electrical Connection

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    64.8

    45.7

    49.515.315.8

    1-20 UNEF-2A

    30

    19.1

    Ø 3

    24.4

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    15.8

    30

    1-20 UNEF-2A

    Ø 3

    DC: M12 x 1AC: 1/2" - 20

    64.8

    45.7

    49.5 6.415.3

    19.1

    24.4

    MHP-DR33LMHP-D2ALMHP-D33L

    MHP-DR33QMHP-D2AQMHP-D33Q

    2

    1

    3

    4

    +UB

    Q

    0 V

    Q

    3

    1

    2

    n. c.

    L2

    L1

    WH

    BN

    BU

    BK

    +UB

    Q

    0 V

    Q

    BU

    BN L1

    L2

    MHP-DR33QMHP-D33Q

    MHP-D2AQMHP-DR33LMHP-D33L

    MHP-D2AL

    1

    2 3

    1

    3

    42

    Sensing Characteristics

    Dimensions (mm)

    Dimensions Drawings

    Electrical Connection

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    64.8

    45.7

    49.515.315.8

    1-20 UNEF-2A

    30

    19.1

    Ø 3

    24.4

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    15.8

    301-20 UNEF-2A

    Ø 3

    DC: M12 x 1AC: 1/2" - 20

    64.8

    45.7

    49.5 6.415.3

    19.1

    24.4

    MHP-DR33LMHP-D2ALMHP-D33L

    MHP-DR33QMHP-D2AQMHP-D33Q

    2

    1

    3

    4

    +UB

    Q

    0 V

    Q

    3

    1

    2

    n. c.

    L2

    L1

    WH

    BN

    BU

    BK

    +UB

    Q

    0 V

    Q

    BU

    BN L1

    L2

    MHP-DR33QMHP-D33Q

    MHP-D2AQMHP-DR33LMHP-D33L

    MHP-D2AL

    1

    2 3

    1

    3

    42

    Dimensions Drawings

    Electrical Connection

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    64.8

    45.7

    49.515.315.8

    1-20 UNEF-2A

    30

    19.1

    Ø 3

    24.4

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    15.8

    30

    1-20 UNEF-2A

    Ø 3

    DC: M12 x 1AC: 1/2" - 20

    64.8

    45.7

    49.5 6.415.3

    19.1

    24.4

    MHP-DR33LMHP-D2ALMHP-D33L

    MHP-DR33QMHP-D2AQMHP-D33Q

    2

    1

    3

    4

    +UB

    Q

    0 V

    Q

    3

    1

    2

    n. c.

    L2

    L1

    WH

    BN

    BU

    BK

    +UB

    Q

    0 V

    Q

    BU

    BN L1

    L2

    MHP-DR33QMHP-D33Q

    MHP-D2AQMHP-DR33LMHP-D33L

    MHP-D2AL

    1

    2 3

    1

    3

    42

    Dimensions Drawings

    Electrical Connection

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    64.8

    45.7

    49.515.315.8

    1-20 UNEF-2A

    30

    19.1

    Ø 3

    24.4

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    15.8

    30

    1-20 UNEF-2A

    Ø 3

    DC: M12 x 1AC: 1/2" - 20

    64.8

    45.7

    49.5 6.415.3

    19.1

    24.4

    MHP-DR33LMHP-D2ALMHP-D33L

    MHP-DR33QMHP-D2AQMHP-D33Q

    2

    1

    3

    4

    +UB

    Q

    0 V

    Q

    3

    1

    2

    n. c.

    L2

    L1

    WH

    BN

    BU

    BK

    +UB

    Q

    0 V

    Q

    BU

    BN L1

    L2

    MHP-DR33QMHP-D33Q

    MHP-D2AQMHP-DR33LMHP-D33L

    MHP-D2AL

    1

    2 3

    1

    3

    42

    Dimensions Drawings

    Electrical Connection

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    64.8

    45.7

    49.515.315.8

    1-20 UNEF-2A

    30

    19.1

    Ø 3

    24.4

    Light on/dark on (if applicable)Sensitivity adjustment (if applicable)

    LEDs (if applicable)Red: output statusGreen: signal strengthAmber: Power (transmitter only)

    15.8

    30

    1-20 UNEF-2A

    Ø 3

    DC: M12 x 1AC: 1/2" - 20

    64.8

    45.7

    49.5 6.415.3

    19.1

    24.4

    MHP-DR33LMHP-D2ALMHP-D33L

    MHP-DR33QMHP-D2AQMHP-D33Q

    2

    1

    3

    4

    +UB

    Q

    0 V

    Q

    3

    1

    2

    n. c.

    L2

    L1

    WH

    BN

    BU

    BK

    +UB

    Q

    0 V

    Q

    BU

    BN L1

    L2

    MHP-DR33QMHP-D33Q

    MHP-D2AQMHP-DR33LMHP-D33L

    MHP-D2AL

    1

    2 3

    1

    3

    42

    V1 Type V12 Type

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 610 Singapore: +65 6779 [email protected]: +1 330 486 [email protected] Germany: +49 621 [email protected]+Fuchs Groupwww.pepperl-fuchs.comSubject to modifications without notice Copyright Pepperl+Fuchs

    Photoelectric Sensors

    Phot

    oele

    ctric

    MH

    P Se

    ries

    Min

    iatu

    re

    (Dimensions in mm)

    See pages 1009-1076for cordsets

    See pages 895-912 for reflectors

    See pages 1105-1128 for accessories

    Accessories

    Panel Mount Bracket Model MHPTB

    25.4

    38.125.4

    44.5 R

    12.7

    20°

    20°

    20°

    20°

    25.4

    12.7

    Mounting Kit Model MHPHDW

    (included with all non-fiber MHP Series sensors)

    Kit includes (1) locknut, (1) O-ring, (2) 1.25” length screws, (2) nuts,

    and (2) washers.

    Side Mount Bracket Model MHPSB