1
Auto Hematology Analyzer BC-5800 5-part differentiation, 29 parameters, 2 histograms + 2 scattergrams Up to 90 samples per hour Laser scatter + Chemical dye + Flow cytometry technology Independent channel and optical method for Basophil measurement Powerful capability to flag abnormal cells Optional autoloader, barcode scanner Large TFT touch screen Large storage capacity: up to 40,000 samples Recommended or customizable decision rules to re-exam abnormal samples Support uni- or bi-directional LIS BC-5800 Auto Hematology Analyzer Before Digital Sheath Flow After Digital Sheath Flow The comparison on histogram 2 separate channels to differentiate WBC BC-5800 counts lymphocyte, monocyte, neutrophil and eosinophil in Diff channel, and basophil in a separated Baso channel. Optical method to test Basophil: more information about cell physiology, more reliable. Digital sheath flow Mindray patented technology can monitor every cell’s status while going through the aperture, this accurately measures the volume of cells, giving a standardized histogram shape. Laser light scatter BC-5800 hematology analyzer utilizes the semiconductor laser for the flow cytometry system. Through calculations of different angles via laser scatters, the instrument provides complete analysis including cell size, granularity and complexity. Chemical dye method by original reagents The basophils and eosinophils can be accurately differentiated by the unique chemical dye method. The Mindray original reagents, control and calibrator is a complete system to ensure high accuracy. Dual acceleration flow cell system Dual acceleration flow cell system reduces the velocity gap between sheath flow and blood cells, ensuring a more stable signal, which allow for accurate measurement via laser scatter. Diff complexity cell size complexity cell size Baso Lvm Mon Neu Eos Bas Other WBC STAT Provide STAT results quickly Minimal interruption to routine workflow Autoloader with 50 tube positions Save time with continuous loading Random access Pre-heater Heat the reagents to proper temperature Maintain all cells in the original physiological status Maximize reaction process 10.4 inch touch screen High resolution User-friendly software Semiconductor laser with heater Reliable, Durable Heater makes the laser more stable Sample Rotatory Valve (SRV) High precision Easy maintenance Blood sensor monitors aspiration volume Uni- or Bi-directional LIS Transmit test results and patient information in bi-directional mode. Support HL7 and 15ID communication protocol. Easily be integrated into your laboratory organization. Data Management Software (DMS) With DMS, data can be transmitted to PC. DMS is a standard configuration of BC-5800 to meet different laboratories’ demand, and offer more customization on report, data editing and net connection. Memory can hold up to 40,000 patient results Save previous results with graphic and numeric information. Re-exam Decision rules recommended by Mindray can help remind to re-exam abnormal samples, reduce post-analytical errors and review rate. Decision rules can also be customized with new input support to fit any standard laboratory practices. Various formats report & User-defined formats report Paper: A4, A5, Letter, Continuous Paper. Report formats: 4 Pre-defined formats & 4 User-defined formats. Quality control Mindray original control and calibrator. Provides 60 QC files, each file can save 310 QC results. Import QC information including lot No., level, exp. date, mean and range values through USB disk. BC-5800 Auto Hematology Analyzer Technical Specifications P/N: ENG-BC5800-21285x6-20100201 2010 DISTRIBUTOR: Principles Impedance method for RBC and PLT counting Cyanide free reagent for hemoglobin test Flow Cytometry (FCM) + Laser light scatter + Chemical dye method for WBC differential analysis and WBC counting Parameters 29 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC. 4 Research parameters include LIC%, LIC#, ALY%, ALY# 2 Histograms for RBC and PLT 2 Scatter grams: 4-differential scatter gram, Basophil scatter gram Reagent Diluent, LEO(I), LEO(II), LBA, LH, Cleanser All reagents configured liquid sensor Performance Parameter Linearity Range Precision Carryover WBC 0-200×109/L ≤2.5% (4-15×109/L) ≤0.5RBC 0-8.2×1012/L ≤1.5% (3.5-6.0×1012/L) ≤0.5HGB 0-260g/L ≤1.5% (110-180g/L) ≤1.0HCT 0-67% ≤1.5%30%-50%≤0.5PLT 0-2000×109/L ≤4.0% (150-500×109/L) ≤1.0Sample Volume Prediluted 40 μL Manual mode (Open vial) 120 μL Auto loader/Manual mode (Closed tube) 180 μL Throughput Up to 90 samples per hour Display 10.4 inch TFT Touch Screen Resolution: 800×600 Multi-language Chinese, Czech, English, French, German, Greek, Italian, Polish, Portuguese, Romanian, Russian, Spanish, Turkish Data Storage Capacity Up to 40,000 results including numeric and graphical information Communication LAN Port supports HL7 and 15ID protocol Interface USB, LAN, COM Support Uni- or bi-directional LIS Printout External Laser printer / Inkjet printer, various printout formats and User-defined formats Operating Environment Temperature: 15°C~30°C Humidity: 30%~85% Power requirement Main unit: 100-240V~50Hz Pneumatic unit: 110/115V~50/60Hz 220/230V~50/60Hz Dimension and Weight Main unit Pneumatic unit Sample loader (Optional) Width (mm) 664 305 516 Depth (mm) 613 475 237 Height (mm) 585 425 90 Weight (kg) ≤76 ≤25 ≤8 Mindray Building, Keji 12th Road South, High-tech Industrial Park, Nanshan, Shenzhen 518057, P.R. China Tel: +86 755 26582888 Fax: +86 755 26582680 E-mail: [email protected] Website: www.mindray.com Mindray is listed on the NYSE under the symbol”MR” Close structure Shield from interference: EMI, dust, etc. Internal barcode scanner Maximize reading capability Preventing errors and reducing misreads

新彩页模板Auto Hematology Analyzer BC-5800 5-part di˜erentiation, 29 parameters, 2 histograms + 2 scattergrams Up to 90 samples per hour Laser scatter + Chemical dye + Flow cytometry

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 新彩页模板Auto Hematology Analyzer BC-5800 5-part di˜erentiation, 29 parameters, 2 histograms + 2 scattergrams Up to 90 samples per hour Laser scatter + Chemical dye + Flow cytometry

Auto Hematology AnalyzerBC-5800

5-part di�erentiation, 29 parameters,

2 histograms + 2 scattergrams

Up to 90 samples per hour

Laser scatter + Chemical dye + Flow

cytometry technology

Independent channel and optical method

for Basophil measurement

Powerful capability to �ag abnormal cells

Optional autoloader, barcode scanner

Large TFT touch screen

Large storage capacity: up to 40,000 samples

Recommended or customizable decision

rules to re-exam abnormal samples

Support uni- or bi-directional LIS

BC-5800Auto Hematology Analyzer

Before Digital Sheath Flow After Digital Sheath Flow The comparison on histogram

2 separate channels to di�erentiate WBCBC-5800 counts lymphocyte, monocyte, neutrophil and eosinophil

in Di� channel, and basophil in a separated Baso channel.

Optical method to test Basophil: more information about cell

physiology, more reliable.

Digital sheath �owMindray patented technology can monitor every cell’s status while going through the aperture,

this accurately measures the volume of cells, giving a standardized histogram shape.

Laser light scatterBC-5800 hematology analyzer utilizes the semiconductor laser for the

�ow cytometry system. Through calculations of di�erent angles via

laser scatters, the instrument provides complete analysis including

cell size, granularity and complexity.

Chemical dye method by original reagentsThe basophils and eosinophils can be accurately di�erentiated by

the unique chemical dye method. The Mindray original reagents,

control and calibrator is a complete system to ensure high accuracy.

Dual acceleration �ow cell systemDual acceleration �ow cell system reduces the velocity gap between

sheath �ow and blood cells, ensuring a more stable signal, which

allow for accurate measurement via laser scatter.

Di�

complexity

cell size

complexity

cell size Baso

Lvm Mon Neu Eos

Bas Other WBC

STATProvide STAT results quicklyMinimal interruption to routine work�ow

Autoloader with 50 tube positionsSave time with continuous loadingRandom access

Pre-heaterHeat the reagents to proper temperatureMaintain all cells in the original physiological statusMaximize reaction process

10.4 inch touch screenHigh resolutionUser-friendly software

Semiconductor laser with heaterReliable, DurableHeater makes the laser more stable

Sample Rotatory Valve (SRV)High precisionEasy maintenanceBlood sensor monitors aspiration volume

Uni- or Bi-directional LISTransmit test results and patient information

in bi-directional mode.

Support HL7 and 15ID communication

protocol.

Easily be integrated into your laboratory

organization.

Data Management Software (DMS)With DMS, data can be transmitted to PC.

DMS is a standard con�guration of BC-5800 to meet di�erent

laboratories’ demand, and o�er more customization on

report, data editing and net connection.

Memory can hold up to 40,000 patient resultsSave previous results with graphic and numeric information.

Re-exam

Decision rules recommended by Mindray can help remind to re-exam

abnormal samples, reduce post-analytical errors and review rate.

Decision rules can also be customized with new input support to �t any

standard laboratory practices.

Various formats report & User-de�ned formats reportPaper: A4, A5, Letter, Continuous Paper.

Report formats: 4 Pre-de�ned formats & 4 User-de�ned formats.

Quality controlMindray original control and calibrator.

Provides 60 QC �les, each �le can save 310 QC results.

Import QC information including lot No., level, exp. date, mean

and range values through USB disk.

BC-5800Auto Hematology Analyzer

Technical Speci�cations

P/N: ENG-BC5800-21285x6-201002012010

DISTRIBUTOR:

PrinciplesImpedance method for RBC and PLT countingCyanide free reagent for hemoglobin testFlow Cytometry (FCM) + Laser light scatter + Chemical dye method for WBC di�erential analysis and WBC counting

Parameters29 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC. 4 Research parameters include LIC%, LIC#, ALY%, ALY#2 Histograms for RBC and PLT2 Scatter grams: 4-di�erential scatter gram, Basophil scatter gram

ReagentDiluent, LEO(I), LEO(II), LBA, LH, CleanserAll reagents con�gured liquid sensor

PerformanceParameter Linearity Range Precision Carryover WBC 0-200×109/L ≤2.5% (4-15×109/L) ≤0.5% RBC 0-8.2×1012/L ≤1.5% (3.5-6.0×1012/L) ≤0.5% HGB 0-260g/L ≤1.5% (110-180g/L) ≤1.0% HCT 0-67% ≤1.5%(30%-50%) ≤0.5% PLT 0-2000×109/L ≤4.0% (150-500×109/L) ≤1.0%

Sample VolumePrediluted 40 µLManual mode (Open vial) 120 µLAuto loader/Manual mode (Closed tube) 180 µL

ThroughputUp to 90 samples per hour

Display10.4 inch TFT Touch ScreenResolution: 800×600

Multi-language Chinese, Czech, English, French, German, Greek, Italian, Polish, Portuguese, Romanian, Russian, Spanish, Turkish

Data Storage CapacityUp to 40,000 results including numeric and graphical information

CommunicationLAN Port supports HL7 and 15ID protocol

InterfaceUSB, LAN, COMSupport Uni- or bi-directional LIS

PrintoutExternal Laser printer / Inkjet printer, various printout formats and User-de�ned formats Operating EnvironmentTemperature: 15°C~30°CHumidity: 30%~85% Power requirementMain unit: 100-240V~50HzPneumatic unit: 110/115V~50/60Hz 220/230V~50/60Hz

Dimension and Weight Main unit Pneumatic unit Sample loader (Optional)Width (mm) 664 305 516Depth (mm) 613 475 237Height (mm) 585 425 90Weight (kg) ≤76 ≤25 ≤8

Mindray Building, Keji 12th Road South, High-tech Industrial Park,Nanshan, Shenzhen 518057, P.R. China

Tel: +86 755 26582888 Fax: +86 755 26582680E-mail: [email protected] Website: www.mindray.com

Mindray is listed on the NYSE under the symbol”MR”

Close structureShield from interference: EMI, dust, etc.

Internal barcode scannerMaximize reading capabilityPreventing errors and reducing misreads