SYMBOLS LIST WIRING DEVICES POWER F X F F S FFT FACP FARA WALL MOUNTED DATA OUTLET WALL MOUNTED CRESTRON PANEL WALL MOUNTED VOIP OUTLET FLOOR MOUNTED DATA OUTLET CEILING MOUNTED DATA OUTLET AV CONNECTION, PROVIDE PASS-THROUGH MUD RINGS AT HIGH & LOW LEVEL. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION WIRELESS ACCESS POINT FIRE ALARM PULL STATION FIRE ALARM HORN FIRE ALARM BELL COMBINATION FIRE ALARM BELL COMBINED WITH STROBE WALL MOUNTED FIRE ALARM STROBE LIGHT CEILING MTD FIRE ALARM STROBE LIGHT COMBINATION FIRE ALARM AND PUBLIC ADDRESS SPEAKER SMOKE DETECTOR (L = LASER, P = PHOTOCELL) RATE-OF-RISE HEAT DETECTOR FIXED TEMPERATURE HEAT DETECTOR COMBINATION HEAT DETECTOR, RATE-OF-RISE & FIXED TEMPERATURE FIRE FIGHTER TELEPHONE FIRE ALARM CONTROL PANEL FIRE ALARM REMOTE ANNUNCIATOR DGP DATA GATHERING PANEL AV R R WALL MOUNTED DUPLEX RECEPTACLE NEMA 5-15R (120V, 15A) WALL MOUNTED QUADRUPLEX RECEPTACLE NEMA 5-15R (120V, 15A) WALL MOUNTED DUPLEX RECEPTACLE NEMA 5-20R (120V, 20A) WALL MOUNTED SIMPLEX RECEPTACLE (SPECIFICATIONS ON POWER PLAN) SPECIALTY RECEPTACLE (SPECIFICATIONS ON POWER PLAN) CEILING MOUNTED QUADRUPLEX RECEPTACLE NEMA 5-15R (120V,15A) FLOOR MOUNTED DUPLEX RECEPTACLE NEMA 5-15R (120V, 15A) FLOOR MOUNTED QUADRUPLEX RECEPTACLE NEMA 5-15R (120V, 15A) DIRECT POWER CONNECTION (SPECIFICATIONS ON POWER PLAN) R WALL MOUNTED QUADRUPLEX RECEPTACLE NEMA 5-20R (125V, 20A, 2P, 3W) ( GROUNDED) FURNITURE MOUNTED DUPLEX RECEPTACLE (SUPPLIED AND WIRED BY DIVISION 26) CEILING MOUNTED DUPLEX RECEPTACLE NEMA 5-15R (120V, 15A) FLOOR MOUNTED FURNITURE SYSTEM POWER FEED SUPPLIED BY FURNITURE MANUFACTURER. ELECTRICAL CONNECTION BY CONTRACTOR. WALL MOUNTED FURNITURE SYSTEM POWER FEED SUPPLIED BY FURNITURE MANUFACTURER. ELECTRICAL CONNECTION BY CONTRACTOR. COMBINATION FLOOR MONUMENT WITH OULETS SHOWN. F B FAN SWITCH MOTORIZED BLINDS SWITCH COMMUNICATIONS SYSTEM FIRE ALARM SYSTEM LIGHTING & LIGHTING CONTROL A LV OS A D PC TC LIGHTING FIXTURE (REFER TO LIGHTING FIXTURE SCHEDULE FOR TYPE) 'A' - DENOTES SWITCH DESIGNATION '1' - DENOTES PANEL DESIGNATION & CIRCUIT NUMBER HALF SHADED FIXTURE DENOTES EMERGENCY LIGHTING WALL MOUNTED OUTLET BOX AND LIGHT FIXTURE (REFER TO LIGHTING FIXTURE SCHEDULE FOR TYPE) CEILING/WALL MTD EXIT LIGHT AND OUTLET BOX. PROVIDE DIRECTIONAL ARROWS AS INDICATED SHADED AREA DENOTES FACE(S) UPON WHICH 'EXIT' APPEARS CEILING MTD OCCUPANCY SENSOR C/W APPROPRIATE SWITCH PACK. 'A' - DENOTES SWITCH DESIGNATION LV' - DENOTES PANEL DESIGNATION & CIRCUIT NUMBER 0-10V DIMMER SWITCH, TO BE USED WITH OCCUPANCY SENSOR. A - DENOTES SWITCH DESIGNATION A 1 A 1 A 1 A VS DECORATOR 0-10V DIMMING MANUAL 'ON'/AUTO 'OFF' SWITCH SENSOR. ARCHITECT TO SELECT COLOR A - DENOTES SWITCH DESIGNATION A LV OS PHOTOSENSOR/DAYLIGHT SENSOR C/W APPROPRIATE SWITCH PACK. 'A' - DENOTES SWITCH DESIGNATION LV' - DENOTES PANEL DESIGNATION & CIRCUIT NUMBER PHOTOCELL REAL TIME CLOCK WALL MOUNTED EMERGENCY REMOTE HEADS CEILING MOUNTED EMERGENCY REMOTE HEADS NOTES: 1. SYMBOLS LIST IS FOR REFERENCE ONLY. NOT ALL SYMBOLS SHOWN ARE USED IN PROJECT. GND ES DC CR REX DR ML DH LB DO C CCTV ACP PS CARD READER DOOR CHIME DOOR CONTACT MAGNETIC DOOR HOLDER AUTOMATIC DOOR OPENER DOOR RELEASE HARDWARE ELECTRIC STRIKE LOCK BUTTON ELECTROMAGNETICLOCK REQUEST TO EXIT DEVICE PUSH BUTTON PAN, TILT, ZOOM CLOSED CIRCUIT SECURITY CAMERA, REQUIRES PoE INJECTOR AND C/W ONE (1) DATA DROP ACCESS CONTROL PANEL POWER SUPPLY PTZ CCTV CLOSED CIRCUIT SECURITY CAMERA C/W DATA DROP A B A A 1 A / B P TV SS E.S. MD ECH EHC EUH FCU FSD VFD FUSED DISCONNECT SWITCH 'A' - DENOTES SWITCH SIZE 'B' - DENOTES FUSE SIZE UN-FUSED DISCONNECT SWITCH 'A' - DENOTES SWITCH SIZE COMBINATION STARTER/DISCONNECT SWITCH 'A' - DENOTES SWITCH SIZE '1' - DENOTES NEMA SWITCH SIZE CIRCUIT BREAKER IN NEMA 1 ENCLOSURE 'A' - DENOTES FRAME SIZE 'B' - DENOTES TRIP SETTING TRANSIENT VOLTAGE SUPPRESSOR MOMENTARY CONTACT PUSHBUTTON SWITCH 'P' - DENOTES PILOT LIGHT MAINTAINED CONTACT EMERGENCY STOP & RESET PUSHBUTTON STATION MOTORIZED DAMPER C/W DISCONNECT SWITCH ELECTRIC CABINET HEATER ELECTRIC HEATING COIL ELECTRIC UNIT HEATER FAN COIL UNIT COMBINATION DAMPER, SMOKE AND FIRE VARIABLE FREQUENCY DRIVE SURFACE TYPE PANELBOARD FLUSH (RECESSED) TYPE PANELBOARD DISTRIBUTION PANEL LIGHTING PANELBOARD BRANCH CIRCUIT: 600/347V POWER PANELBOARD BRANCH CIRCUIT: 600/347V OU/OR 208/120V LP PP RECEPTACLE PANELBOARD BRANCH CIRCUIT: 208/120V RP LVRC LOW VOLTAGE RELAY CABINET JB PB JUNCTION BOX (SCHEMATIC) PULL BOX (SCHEMATIC) CONDUIT RUN CONCEALED IN CEILING SPACE AND/OR IN WALLS EMBEDDED/BURIED CONDUIT LOW-PROFILE SURFACE MTD 2-CHANNEL RACEWAY, WITH OUTLETS SHOWN LOW-PROFILE SURFACE MTD 3-CHANNEL RACEWAY, WITH OUTLETS SHOWN WALL MOUNTED GROUND BUS BAR CONDUIT & RACEWAY SYSTEMS SECURITY & DOOR HARDWARE PANELBOARDS & CABINETS ABBREVIATIONS GENERAL AFF ABOVE FINISHED FLOOR BFG BELOW FINISHED GRADE C/W COMPLETE WITH IN INCHES EC EXISTING ITEM TO REMAIN & BE RECIRCUITED BOM BILL OF MATERIALS MM MILLIMETERS MTD MOUNTED EX EXISTING ITEM TO REMAIN ER EXISTING ITEM TO BE RELOCATED EM EMERGENCY DWG DRAWING ATS AUTOMATIC TRANSFER SWITCH MCC MOTOR CONTROL CENTRE NIC NOT IN CONTRACT NTS NOT TO SCALE RL RELOCATED ITEM STD STANDARD SIM SIMILAR TYP TYPICAL BAS BUILDING AUTOMATION SYSTEM BMS BUILDING MANAGEMENT SYSTEM GND GROUND CB CIRCUIT BREAKER LCP LIGHTING CONTROL PANEL LVR LOW VOLTAGE RELAY MSP MOTOR STARTER PANEL RCSP REMOTE CONTROL/SIGNAL PANEL SB SWITCHBOARD SG SWITCHGEAR SS SUBSTATION UPS UNINTERRUPTIBLE POWER SUPPLY AWG AMERICAN WIRE GAUGE WP WEATHERPROOF BND BOND C CONDUIT TEM / EMT ELECTRICAL METALLIC TUBING GFI GROUND FAULT INTERRUPTOR P POLE PH PHASE TL TWIST-LOCK W WIRE AC AIR CONDITIONING ACCU AIR COOLED CONDENSING UNIT AHU AIR HANDLING UNIT BB BYPASS BOX CP CONDENSATE PUMP CU CONDENSING UNIT EF EXHAUST FAN FPB FAN POWERED BOX RTU ROOFTOP UNIT VAV VARIABLE AIR VOLUME BOX ER ELECTRIC RADIATOR AV AUDIO VISUAL FA FIRE ALARM CM COFFEE MACHINE COMM COMMUNICATIONS DW DISHWASHER REF REFRIGERATOR CRAC COMPUTER ROOM AIR CONDITIONER SBO SUPPLIED BY OTHERS, INSTALLED BY DIV. 26 ELECTRICAL WIRING MECHANICAL EQUIPMENT MISCELLANEOUS NOTES: 1. ABBREVIATIONS LIST IS FOR REFERENCE ONLY. NOT ALL ABBREVIATIONS SHOWN ARE USED IN PROJECT. 1. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT MOUNTING HEIGHTS, FINISHES, DIMENSIONS AND LOCATIONS OF DEVICES INCLUDING LIGHT FIXTURES, PRIOR TO COMMENCEMENT OF WORK. ANY DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS AND/OR EXISTING CONDITIONS ARE TO BE PROMPTLY REFERRED TO ENGINEER FOR INSTRUCTIONS BEFORE ANY WORK COMMENCES. 2. INSTALLATION OF ELECTRICAL EQUIPMENT SHALL BE COMPLETED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 3. PROVIDE SEPARATE PRICES FOR SCOPE OF WORK, AS SHOWN. WHERE A SEPARATE PRICE IS INDICATED, THE ENTIRE SCOPE OF WORK, INCLUDING PROVIDING ALL MATERIAL, AS WELL AS THE MEANS AND METHODS TO EXECUTE THE WORK AS GOVERNED BY THE GENERAL AND SPECIFIC CONDITIONS OF THE CONTRACT, IS TO BE INCLUDED IN THE SEPARATE PRICE BID SCOPE, INCLUDING ANY NECESSARY DEMOLITION AND RE-WORK, AS APPLICABLE. 4. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT. 5. THE EXISTING SYSTEMS SHALL BE LEFT IN PERFECT WORKING ORDER UPON COMPLETION OF ALL NEW WORK. 6. CONTRACTOR SHALL PROVIDE AND CONNECT ALL RACEWAYS AND WIRING FROM EQUIPMENT, DEVICES AND LIGHTING FIXTURES TO ITS SOURCE OF POWER AND CONTROLS. 7. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS OF FINISHED CONSTRUCTION PRIOR TO FABRICATION AND INSTALLATION OF FIXTURES AND EQUIPMENT. 8. ELECTRICAL CONTRACTOR SHALL VERIFY SWITCHES, RECEPTACLES AND PLATE FINISHES WITH THE ARCHITECT BEFORE PERFORMING HIS INSTALLATION. ALL COVERPLATES SHALL BE AS SPECIFIED BY ARCHITECT. 9. EXISTING ELECTRICAL EQUIPMENT AND PANELBOARDS SHALL BE MODIFIED AS REQUIRED TO ACCOMMODATE THE WORK OF THIS CONTRACT. REPLACE EXISTING CIRCUIT BREAKERS IN PANELS WITH IDENTICAL NEW BREAKERS AS REQUIRED AND PROVIDE UPDATED TYPEWRITTEN DIRECTORIES. 10. COORDINATE LOCATION OF OUTLETS AND SWITCHES WITH FURNITURE AND EQUIPMENT LAYOUTS AND WITH OWNER'S REPRESENTATIVE. 11. ANY EXISTING WORK DAMAGED AS A RESULT OF PERFORMING THE WORK OF THIS CONTRACT SHALL BE REPAIRED OR REPLACED AS REQUIRED. MATERIAL AND FINISH TO MATCH EXISTING TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE. 12. ALL ELECTRICAL WORK IN ADJOINING AREAS WHICH IS REQUIRED TO FUNCTION BUT IS AFFECTED BY THIS WORK SHALL BE RECONNECTED AND RESTORED TO ITS PRESENT FUNCTION AS PART OF THE ELECTRICAL SYSTEM OF THE BUILDING(S). 13. ALL BRANCH CIRCUIT WIRING SHALL BE RUN CONCEALED IN WALLS AND/OR ABOVE HUNG CEILING UNLESS OTHERWISE NOTED. 14. WIRING IN AIR PLENUM HUNG CEILINGS INSTALLED WITHOUT CONDUIT OR EMT SHALL BE TEFLON JACKETED AND FT-6 RATED. 15. NO LOW VOLTAGE WIRING SHALL BE PERMITTED IN THE SAME RACEWAY AS POWER WIRING. 16. CONTRACTOR TO DE-RATE CONDUCTORS IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE WHEN INSTALLING MORE THAN THREE (3) CIRCUITS IN A 3 4 "C HOMERUN. 17. FOR WIRING IN EXISTING PARTITIONS WHERE EMT INSTALLATION IS IMPRACTICAL, FLEXIBLE GALVANIZED STEEL CONDUIT SHALL BE ACCEPTED. COORDINATE EXACT SIZE WITH SPECIFIED CABLING REQUIREMENTS. MINIMUM SIZE USED SHALL BE 3 4 ". 18. PROVIDE NYLON PULL CORDS IN ALL EMPTY RACEWAYS. 19. ALL CONDUITS FOR BRANCH CIRCUITING AND/OR COMMUNICATIONS CABLING, INCLUDING THOSE RUN IN CEILING OF FLOOR BELOW SHALL BE IDENTIFIED AT EVERY 50 FEET OF LENGTH AND AT EACH OUTLET AND PULL BOX WITH PANEL AND CIRCUIT NUMBER OR SYSTEM NAME. 20. CONTRACTOR SHALL PROVIDE AN EMPTY CONDUIT SYSTEM WITH NYLON PULL CORDS AND OUTLET BOXES FOR INSTALLATION OF LOW TENSION WIRING SYSTEM. VERIFY EXACT REQUIREMENTS WITH SYSTEM VENDOR. 21. THE MINIMUM RATING OF DISCONNECT SWITCHES SHALL BE EQUAL TO OR GREATER THAN THE RATING OF THE PROTECTION DEVICE ON THE SUPPLY SIDE OF THE DISCONNECT SWITCH. MINIMUM DISCONNECT SWITCH SIZE SHALL BE 30 AMPERES. 1. NOTES AND GRAPHIC REPRESENTATIONS SHALL NOT LIMIT THE EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT THE SITE, CAREFULLY EXAMINE EXISTING CONDITIONS AND SHALL PERFORM ALL DEMOLITION REQUIRED TO ACHIEVE THE FINAL DESIGN INTENT AS REQUIRED BY THE CONTRACT DOCUMENTS. EXTENT OF ALL DEMOLITION WORK SHALL BE COORDINATED WITH THE ARCHITECT. 2. EQUIPMENT INDICATED TO BE REMOVED SHALL BE TAKEN FROM THE SITE AND DISPOSED OF IN ACCORDANCE WITH APPLICABLE LAWS AND ENVIRONMENTAL REGULATIONS. LANDLORD SHALL HAVE THE OPTION TO RECEIVE ANY ITEMS CALLED TO BE REMOVED PRIOR TO REMOVAL FROM SITE. EQUIPMENT REQUIRED TO BE TURNED OVER TO THE OWNER SHALL BE PLACED IN A MUTUALLY ACCEPTABLE LOCATION. 3. THE WORK SHALL INCLUDE THE REMOVAL OF MATERIALS AS DIRECTED. PRIOR TO REMOVING EQUIPMENT AND MATERIALS FROM THE PROJECT SITE, THE BUILDING MANAGER SHALL INSPECT AND ADVISE WHICH ITEMS WILL BE RESTORED. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL FROM THE PREMISES ALL DEBRIS RESULTING FROM REMOVAL OF WORK. 5. CONTRACTOR SHALL REMOVE BACK TO SOURCE ALL REMAINING SERVICES, AT ALL POINTS OF DISCONNECTION, UNLESS OTHERWISE INDICATED OR IMPRACTICAL DUE TO CONNECTION WITH EXISTING-TO-REMAIN SERVICES. 6. DEMOLITION AND OTHER WORK WHICH CREATES DISTURBING NOISE, MUST BE PERFORMED AFTER NORMAL WORKING HOURS OR ON WEEKENDS. THE DELIVERY, HANDLING, AND INSTALLING OF MATERIALS, EQUIPMENT AND DEBRIS MUST BE ARRANGED TO AVOID ANY INCONVENIENCE AND ANNOYANCE TO OTHER TENANTS. CLEANING MUST BE CONTROLLED TO PREVENT DIRT AND DUST FROM INFILTRATING INTO ADJACENT TENANT OR ELECTRICAL AREAS. WELDING OR BUR. 7. CUT, PATCH, AND PAINT CEILINGS AND SLAB AS REQUIRED TO MATCH EXISTING CONDITIONS. 8. ALL POWER CONDUCTORS, CONTROL WIRING AND CONDUIT ASSOCIATED WITH MECHANICAL EQUIPMENT SUCH AS FANS, AIR CONDITIONING UNITS, PUMPS, ETC. DESIGNATED FOR REMOVAL ON THE HVAC AND PLUMBING DEMOLITION DRAWINGS SHALL BE REMOVED BACK TO THE SOURCE OF POWER AND DISCONNECTED. ALL MOTOR STARTERS, DISCONNECT SWITCHES, CONTROL DEVICES, ETC. SHALL BE REMOVED. REFER TO HVAC AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 9. EXISTING ELECTRICAL EQUIPMENT AND PANELBOARDS SHALL BE MODIFIED AS REQUIRED TO ACCOMMODATE THE WORK OF THIS CONTRACT. REPLACE EXISTING CIRCUIT BREAKERS IN PANELS WITH IDENTICAL NEW BREAKERS AS REQUIRED AND PROVIDE UPDATED TYPEWRITTEN DIRECTORIES. 10. THIS CONTRACTOR SHALL MAINTAIN CONTINUITY OF SERVICE TO EXISTING BUILDING FIRE ALARM SYSTEM. COORDINATE WITH BUILDING MANAGER.THE REMOVAL OF ALL FIRE ALARM, COMMUNICATIONS, DATA AND SECURITY EQUIPMENT AND ASSOCIATED CABLING SHALL BE COORDINATED WITH BUILDING OPERATING PERSONNEL. EXISTING BASE BUILDING FIRE ALARM SYSTEM SHALL REMAIN IN OPERATION DURING BOTH DEMOLITION AND CONSTRUCTION STAGES OF THIS PROJECT. 11. WHERE REMOVAL OF EXISTING ELECTRICAL EQUIPMENT WILL RESULT IN OUTAGES IN AREAS NOT TO BE DEMOLISHED, THE CONTRACTOR SHALL COORDINATE IN ADVANCE AND OBTAIN THE APPROVAL OF THE BUILDING MANAGER. PROVIDE MINIMUM SEVEN (7) DAY ADVANCE NOTICE. 12. WHERE PORTIONS OF AN EXISTING BRANCH CIRCUIT ARE REMOVED, WIRING TO REMAIN DEVICES ON THE CIRCUIT SHALL BE RECONNECTED OR MODIFIED IN AN APPROVED MANNER AS REQUIRED TO MAINTAIN CONTINUITY OF THE AFFECTED BRANCH CIRCUIT AND OPERATION OF THE REMAINING DEVICES. 13. FEEDERS AND BRANCH CIRCUITS TO BE REMOVED - CONDUIT AND SUPPORTS SHALL BE REMOVED TO THE PANEL OF ORIGIN OR THE BOUNDARY OF THE PROJECT AREA. WIRING SHALL BE REMOVED TO THE PANEL OF ORIGIN. WHERE EMPTY CONDUITS REMAIN, INSTALL A PULL STRING AND IDENTIFY AT BOTH ENDS. FEEDERS AND BRANCH CIRCUITS TO BE RE-USED - REMOVE CONDUIT AND WIRING TO LOCATIONS WHICH AVOID CONFLICTS WITH NEW WORK. INSTALL JUNCTION BOXES, TAPE OFF CONDUCTORS AND IDENTIFY WITH PANEL AND CIRCUIT NUMBER. 1. THE CONTRACTOR SHALL VISIT THE PREMISES AND COMPARE SAME WITH A FULL SET OF BID DOCUMENTS BEFORE PROCEEDING WITH ANY WORK IN OCCUPIED AREAS, THE CONTRACTOR SHALL APPLY TO LANDLORD FOR PERMISSIONS TO ENTER SUCH AREAS. THE CONTRACTOR IS OBLIGATED TO PERFORM WORK ONLY AT TIMES DESIGNATED BY THE LANDLORD AND/OR TENANT. THERE WILL BE NO ADDITIONAL COMPENSATION FOR THE WORK PERFORMED PREMIUM TIME WITHOUT PRIOR WRITTEN APPROVAL. 2. CONTRACTOR SHALL COORDINATE THE WORK WITH ALL TRADES AND EXISTING CONDITIONS. 3. CONTRACTOR SHALL COORDINATE AND REVIEW SLAB PENETRATIONS WITH BUILDING STRUCTURAL ENGINEERS. 1. GENERAL 1.1. CONTRACTOR SHALL FURNISH ALL REQUIRED CONDUITS, WIRING, AND JUNCTION BOXES TO ENERGIZE EQUIPMENT INDICATED. 1.2. CONTRACTOR SHALL COORDINATE ON SITE AND WITH THE ARCHITECT FOR THE EXACT LOCATION OF ALL FLOOR AND WALL MOUNTED DEVICES PRIOR TO THE START OF ANY SUCH WORK. 1.3. CONTRACTOR SHALL MAINTAIN CONTINUITY TO ALL EXISTING CIRCUITRY TO REMAIN WHICH ARE AFFECTED BY THE SCOPE OF WORK. CONTRACTOR TO FURNISH AND INSTALL ALL NECESSARY WIRES, CONDUIT AND JUNCTION BOXES REQUIRED TO KEEP CONTINUITY. 1.4. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EQUIPMENT TO BE SUPPLIED BY OTHER TRADES AND INSTALLED AND/OR WIRED UNDER THIS SECTION. 2. POWER 2.1. ALL BRANCH WIRING SHALL BE CONCEALED IN WALLS AND ABOVE HUNG CEILING. 2.2. WHEN PULLING BACK WIRING AND/OR DEMOLISHING WALLS FOR INSTALLED EQUIPMENT, COORDINATE WITH EXISTING MECHANICAL EQUIPMENT AND SERVICES AND TEMPORARILY RELOCATE EQUIPMENT AS NECESSARY. 2.3. ALL EXISTING ELECTRICAL EQUIPMENT AND DEVICES TO REMAIN IN ALL AREAS INDICATED AS OUTSIDE OF THE PROJECT. 2.4. PROVIDE SEPARATE NEUTRAL WIRE FOR EACH DEDICATED CIRCUIT. 2.5. VERIFY EXACT POWER REQUIREMENTS OF MECHANICAL EQUIPMENT BEFORE ROUGHING. REFER TO MECHANICAL SHOP DRAWINGS FOR MANUFACTURERS ELECTRICAL DATA AND INSTALLATION REQUIREMENTS. ADVISE CONSULTANT OF ANY DISCREPANCIES. 2.6. IDENTIFY AND LABEL ALL NEW OR RELOCATED POWER RECEPTACLES. 2.7. WHERE WIRING DEVICES ARE INDICATED TO BE REMOVED AND RELOCATED, PROVIDE NEW WIRING DEVICE BUT RELOCATE EXISTING CIRCUIT AND JUNCTION BOX AS REQUIRED. 2.8. ELECTRICAL CONTRACTOR RESPONSIBLE FOR PROVIDING NEW CONDUIT AND INFRASTRUCTURE AS REQUIRED FOR COMMUNICATIONS SYSTEMS IN ADDITION TO WORK SHOWN ON THIS DRAWING. ELECTRICAL CONTRACTOR IS TO REVIEW, COORDINATE AND CARRY THE SCOPE OF WORK AS SHOWN ON THE COMMUNICATIONS DRAWINGS. 2.9. CONTRACTOR MUST PRACTICE PROPER LOCK OUT AND TAG OUT PROCEDURES. 2.10. BEAM CLAMPS ARE NOT PERMITTED TO HANG OR SUPPORT ELECTRICAL SERVICES. 2.11. CIRCUITS SHOWN ARE FOR GROUPING PURPOSES ONLY. CONTRACTOR TO VERIFY EXACT CIRCUIT NUMBERS IN FIELD AND REUSE CIRCUITS FROM THE DEMOLITION PHASE TO FEED NEW/RELOCATED EQUIPMENT. CONFIRM AVAILABILITY OF CIRCUITS PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR TO CARRY COST FOR QUANTITY OF BREAKERS EQUAL TO NEW CIRCUITS ON LAYOUT AS PART OF BID. PROVIDE 15A.1P CIRCUIT BREAKERS FOR NEW CIRCUITS U.O.N. EXTEND WIRING AND CONDUIT TO SUIT FOR EXISTING-TO-REMAIN AND RELOCATED LOADS AS REQUIRED. A MAXIMUM OF FOUR (4) DUPLEX RECEPTACLES ALLOWED PER PANEL CIRCUIT. UPDATE ALL PANEL SCHEDULES UTILIZED FOR CIRCUITING AS PART OF THIS PROJECT. 2.12. ALL WORK REQUIRING ELECTRICAL SHUTDOWN WHICH WILL AFFECT OTHER FLOORS OF THE BUILDING OR EVEN AFFECT THE NORMAL CONTINUATION OF CONSTRUCTION WORK ON THESE FLOORS, SHALL BE DONE ON OVERTIME HOURS, AND SHALL NOT DISTURB CONTINUITY OF ELECTRICAL SERVICE TO EXISTING TENANTS ON THE AFFECTED FLOORS. COORDINATE SHUTDOWN REQUIREMENTS WITH BUILDING MANAGEMENT PROVIDING A MINIMUM OF ONE WEEK ADVANCE NOTICE. 2.13. WHERE MULTIPLE SWITCHES AND RECEPTACLES ARE INDICATED AT THE SAME LOCATION, THEY SHALL BE MOUNTED BEHIND A COMMON FACEPLATE. 2.14. INCREASE THE SIZE OF BRANCH CIRCUIT CONDUCTORS AND HOME RUNS AS REQUIRED SO THAT THE TOTAL VOLTAGE DROP, FROM PANELBOARDS TO LOADS, DOES NOT EXCEED 3% UNDER LOAD. 2.15. CONTRACTOR SHALL VERIFY THE EXACT CIRCUIT NUMBER IN THE FIELD, WHEN BRANCH CIRCUITS ARE INDICATED TO BE CONNECTED TO EXISTING PANELBOARDS. REFER TO PANELBOARD DESIGNATION LEGEND ON THIS DRAWING FOR PANELBOARD ABBREVIATIONS AND CORRESPONDING PANELBOARD NAMES. 2.16. UNDERFLOOR CONDUIT ROUTING SHOWN FOR DIAGRAMMATIC PURPOSES ONLY. CONTRACTOR SHALL COORDINATE EXACT CONDUIT ROUTING IN THE FIELD AND WITH OTHER TRADES. PRIOR TO INSTALLATION, APPROVAL FOR ALL CONDUIT ROUTING IN THE SLAB OF THE FLOOR SHALL BE OBTAINED FROM THE BASE BUILDING STRUCTURAL ENGINEER AND BUILDING MANAGEMENT. ELECTRICAL PROJECT NOTES GENERAL COORDINATION DEMOLITION POWER & SYSTEMS REMOVAL WORK 14. ALL WORK SHALL BE PROPERLY IDENTIFIED AFTER DEMOLITION. UPDATE ALL PANEL SCHEDULES TO REFLECT EQUIPMENT AND CIRCUIT REMOVALS. 15. WHERE EXISTING FLOOR MOUNTED DEVICE IS TO BE REMOVED, CONTRACTOR SHALL FILL EXISTING SLAB PENETRATIONS WITH cUL LISTED AND APPROVED NON-SHRINKABLE WATERPROOF AND FIRESTOPPING MATERIALS FLUSH TO FLOOR SLAB AND CAPPED. DEMOLITION CONTINUED 1. GENERAL 1.1. FOR EXACT LOCATION AND MOUNTING HEIGHTS OF ALL LIGHTING FIXTURES, SWITCHES AND JUNCTION BOXES SEE ARCHITECTURAL DRAWINGS. 1.2. CONTRACTOR SHALL VISIT THE SITE TO DETERMINE THE EXTENT OF THE ALL EXISTING CONDITIONS PRIOR TO SUBMITTING ANY QUOTATION. 1.3. ANY DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS AND/OR EXISTING CONDITIONS ARE TO BE PROMPTLY REFERRED TO ENGINEER FOR INSTRUCTIONS BEFORE ANY WORK COMMENCES. 1.4. CONTRACTOR SHALL FURNISH ALL REQUIRED CONDUIT, WIRE AND BOXES AS WELL AS CEILING OUTLETS AND WHIPS TO ENERGIZE LIGHTING FIXTURES AS INDICATED. 1.5. CONTRACTOR SHALL MAINTAIN CONTINUITY IN ALL EXISTING CIRCUITRY TO REMAIN WHICH IS AFFECTED BY THE SCOPE OF WORK. CONTRACTOR TO FURNISH ALL NECESSARY WIRES, CONDUIT AND JUNCTION BOXES REQUIRED TO KEEP CONTINUITY. 2. LIGHTING 2.1. REVISE EXISTING LIGHTING WIRING TO ACCOMMODATE NEW LIGHTING LAYOUT. BALANCE THE LOADS. 2.2. ALL LUMINAIRES SHALL BE INSTALLED ACCURATELY IN LINE & LEVEL. 2.2. ANY RELOCATION OF LIGHTING LUMINAIRES REQUIRED DUE THE SITE CONDITIONS SHALL BE APPROVED BY THE ENGINEER PRIOR TO PROCEEDING WITH WORK. 2.3. ALL EXISTING LUMINAIRES WHICH ARE REMAINING OR TO BE RELOCATED, SHALL BE CLEANED, RE-LAMPED & CHECKED FOR PROPER OPERATION, AS NECESSARY. ENSURE THEY ARE FULLY FUNCTIONAL BEFORE PLACING BACK INTO SERVICE. 2.4. ALL NEW OR RELOCATEDLUMINAIRES ARE TO BE CHAINED TO THE ABOVE CEILING FLOOR PAN. 2.5. REFER TO ARCHITECTURE DRAWINGS FOR EXACT LUMINAIRE LENGTHS. 3. LIFE SAFETY SYSTEM 3.1. REUSE EXISTING FIRE ALARM DEVICES. RELOCATE DEVICES AS INDICATED ON DRAWING. RE-VERIFY ALL DEVICES IN THE SPACE. 3.2. AFTER COMPLETION OF WORK THE FIRE ALARM SYSTEM MUST BE TESTED AND VERIFIED AS PER STANDARD ULC S537 3.3. EMERGENCY FIXTURE LOCATIONS ARE SHOWN AT DESIRED LOCATIONS. CONTRACTOR TO CONNECT TO THE NEAREST EXISTING EMERGENCY LIGHTING CIRCUIT IN THE AREA. CONTRACTOR TO CONFIRM IF EXISTING CIRCUIT HAS ADEQUATE CAPACITY TO ACCOMMODATE NEW LIGHT FIXTURES. 3.4. ALL NEW FIRE ALARM DEVICES ARE TO BE LISTED FOR USE WITH EXISTING FIRE ALARM SYSTEM. 3.5. COORDINATE TIE-IN OF NEW FIRE ALARM COMPONENTS AND DEVICES WITH BASE BUILDING FIRE ALARM VENDOR. 3.6. EXIT SIGNS ARE TO BE ILLUMINATED FOR A MINIMUM OF 30 MINUTES UPON LOSE OF POWER UNLESS POWERED FROM A DESIGNATED EMERGENCY POWER SOURCE. LIGHTING SYSTEMS ELECTRICAL DRAWING LIST SHEET NUMBER SHEET TITLE ISSUED FOR ISSUE DATE E-001 ELECTRICAL COVER PAGE ISSUED FOR TENDER 2020-02-03 E-101 ELECTRICAL SPECIFICATIONS SHEET 1 ISSUED FOR TENDER 2020-02-03 E-102 ELECTRICAL SPECIFICATIONS SHEET 2 ISSUED FOR TENDER 2020-02-03 E-311 POWER AND SYSTEMS NEW WORK PLAN ISSUED FOR TENDER 2020-02-03 E-401 LIGHTING DEMOLITION PLAN ISSUED FOR TENDER 2020-02-03 E-411 LIGHTING NEW WORK PLAN ISSUED FOR TENDER 2020-02-03 E-601 PANEL SCHEDULES ISSUED FOR TENDER 2020-02-03 LC LIGHTING CONTROL HUB www.loringengineers.com LORING CONSULTING ENGINEERS, INC. TEL. (647) 352-9999 TORONTO, ON M4V 2Y7 55 ST. CLAIR AVE. W, SUITE 201 NEW YORK, NY ● WASHINGTON, DC ● PRINCETON, NJ ● DURHAM, NC ● TORONTO, ON Checked: DRAWINGS ARE NOT TO BE SCALED. CONSTRUCTION MUST CONFIRM TO ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION. CONTRACTOR MUST VERIFY AND ACCEPT RESPONSIBILITY FOR ALL DIMENSIONS AND CONDITIONS ON SITE AND SHALL NOTIFY THE APPROPRIATE CONSULTANT OF DISCREPANCIES WITH OR VARIATIONS FROM THE INFORMATION PROVIDED BEFORE PROCEEDING WITH THE WORK. THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNLESS SPECIFICALLY ISSUED "FOR CONSTRUCTION" OR OTHERWISE CONFORMING TO THE DRAWINGS THAT FORM THE BASIS FOR WHICH A BUILDING PERMIT FOR THE PROJECT HAS BEEN ISSUED. ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS IN PART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECT'S WRITTEN PERMISSION. N O T E S 11407 Entered: Plot: HIGHLAND HALL SHELL SPACE INTERIOR RETROFIT (UTSC PROJECT 2019-11) UNIVERSITY OF TORONTO SCARBOROUGH 1265 MILITARY TRAIL, TORONTO ON, M1C 1A4 Project North 2019-09-12 Project No: REF DATE DESCRIPTION A 2019/09/13 ISSUED FOR 100%DD B 2019/12/02 ISSUED FOR COORDINATION C 2019/12/03 ISSUED FOR 99% REVIEW D 2019/12/11 ISSUED FOR PERMIT E 2020/02/03 ISSUED FOR TENDER ELECTRICAL COVER PAGE JF RAS E-001

E-601 PANEL SCHEDULES · ceiling mtd occupancy sensor c/w appropriate switch pack. 'a' - denotes switch designation ... electric heating coil electric unit heater fan coil unit combination

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: E-601 PANEL SCHEDULES · ceiling mtd occupancy sensor c/w appropriate switch pack. 'a' - denotes switch designation ... electric heating coil electric unit heater fan coil unit combination

SYMBOLS LISTWIRING DEVICES POWER

F

X

F

F

S

FFT

FACP

FARA

WALL MOUNTED DATA OUTLET

WALL MOUNTED CRESTRON PANEL

WALL MOUNTED VOIP OUTLET

FLOOR MOUNTED DATA OUTLET

CEILING MOUNTED DATA OUTLET

AV CONNECTION, PROVIDE PASS-THROUGH MUD RINGS AT HIGH & LOWLEVEL. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION

WIRELESS ACCESS POINT

FIRE ALARM PULL STATION

FIRE ALARM HORN

FIRE ALARM BELL

COMBINATION FIRE ALARM BELL COMBINED WITH STROBE

WALL MOUNTED FIRE ALARM STROBE LIGHT

CEILING MTD FIRE ALARM STROBE LIGHT

COMBINATION FIRE ALARM AND PUBLIC ADDRESS SPEAKER

SMOKE DETECTOR (L = LASER, P = PHOTOCELL)

RATE-OF-RISE HEAT DETECTOR

FIXED TEMPERATURE HEAT DETECTOR

COMBINATION HEAT DETECTOR, RATE-OF-RISE & FIXED TEMPERATURE

FIRE FIGHTER TELEPHONE

FIRE ALARM CONTROL PANEL

FIRE ALARM REMOTE ANNUNCIATOR

DGP DATA GATHERING PANEL

AV

RR

WALL MOUNTED DUPLEX RECEPTACLENEMA 5-15R (120V, 15A)

WALL MOUNTED QUADRUPLEX RECEPTACLENEMA 5-15R (120V, 15A)

WALL MOUNTED DUPLEX RECEPTACLENEMA 5-20R (120V, 20A)

WALL MOUNTED SIMPLEX RECEPTACLE(SPECIFICATIONS ON POWER PLAN)

SPECIALTY RECEPTACLE(SPECIFICATIONS ON POWER PLAN)

CEILING MOUNTED QUADRUPLEX RECEPTACLENEMA 5-15R (120V,15A)

FLOOR MOUNTED DUPLEX RECEPTACLENEMA 5-15R (120V, 15A)

FLOOR MOUNTED QUADRUPLEX RECEPTACLENEMA 5-15R (120V, 15A)

DIRECT POWER CONNECTION(SPECIFICATIONS ON POWER PLAN)

R

.

WALL MOUNTED QUADRUPLEX RECEPTACLENEMA 5-20R (125V, 20A, 2P, 3W) ( GROUNDED)

FURNITURE MOUNTED DUPLEX RECEPTACLE(SUPPLIED AND WIRED BY DIVISION 26)

CEILING MOUNTED DUPLEX RECEPTACLENEMA 5-15R (120V, 15A)

FLOOR MOUNTED FURNITURE SYSTEM POWER FEED SUPPLIED BYFURNITURE MANUFACTURER. ELECTRICAL CONNECTION BY CONTRACTOR.

WALL MOUNTED FURNITURE SYSTEM POWER FEED SUPPLIED BYFURNITURE MANUFACTURER. ELECTRICAL CONNECTION BY CONTRACTOR.

COMBINATION FLOOR MONUMENT WITH OULETS SHOWN.

F

B

FAN SWITCH

MOTORIZED BLINDS SWITCH

COMMUNICATIONS SYSTEM

FIRE ALARM SYSTEM

LIGHTING & LIGHTING CONTROL

A

LVOS

AD

PC

TC

LIGHTING FIXTURE(REFER TO LIGHTING FIXTURE SCHEDULE FOR TYPE)'A' - DENOTES SWITCH DESIGNATION'1' - DENOTES PANEL DESIGNATION & CIRCUIT NUMBERHALF SHADED FIXTURE DENOTES EMERGENCY LIGHTING

WALL MOUNTED OUTLET BOX AND LIGHT FIXTURE(REFER TO LIGHTING FIXTURE SCHEDULE FOR TYPE)

CEILING/WALL MTD EXIT LIGHT AND OUTLET BOX.PROVIDE DIRECTIONAL ARROWS AS INDICATEDSHADED AREA DENOTES FACE(S) UPON WHICH 'EXIT' APPEARS

CEILING MTD OCCUPANCY SENSOR C/W APPROPRIATE SWITCH PACK.'A' - DENOTES SWITCH DESIGNATIONLV' - DENOTES PANEL DESIGNATION & CIRCUIT NUMBER

0-10V DIMMER SWITCH, TO BE USED WITH OCCUPANCY SENSOR.A - DENOTES SWITCH DESIGNATION

A1

A1

A1

AVS

DECORATOR 0-10V DIMMING MANUAL 'ON'/AUTO 'OFF' SWITCH SENSOR.ARCHITECT TO SELECT COLORA - DENOTES SWITCH DESIGNATION

A

LVOS

PHOTOSENSOR/DAYLIGHT SENSOR C/W APPROPRIATE SWITCH PACK.'A' - DENOTES SWITCH DESIGNATIONLV' - DENOTES PANEL DESIGNATION & CIRCUIT NUMBER

PHOTOCELL

REAL TIME CLOCK

WALL MOUNTED EMERGENCY REMOTE HEADS

CEILING MOUNTED EMERGENCY REMOTE HEADSNOTES:

1. SYMBOLS LIST IS FOR REFERENCE ONLY. NOT ALL SYMBOLS SHOWN ARE USED IN PROJECT.

GND

ES

DC

CR

REX

DR

ML

DH

LB

DO

C

CCTV

ACP

PS

CARD READER

DOOR CHIME

DOOR CONTACT

MAGNETIC DOOR HOLDER

AUTOMATIC DOOR OPENER

DOOR RELEASE HARDWARE

ELECTRIC STRIKE

LOCK BUTTON

ELECTROMAGNETICLOCK

REQUEST TO EXIT DEVICE

PUSH BUTTON

PAN, TILT, ZOOM CLOSED CIRCUIT SECURITY CAMERA, REQUIRES PoEINJECTOR AND C/W ONE (1) DATA DROP

ACCESS CONTROL PANEL

POWER SUPPLY

PTZCCTV

CLOSED CIRCUIT SECURITY CAMERA C/W DATA DROP

AB

A

A1

A / B

P

TVSS

E.S.

MD

ECH

EHC

EUH

FCU

FSD

VFD

FUSED DISCONNECT SWITCH'A' - DENOTES SWITCH SIZE'B' - DENOTES FUSE SIZE

UN-FUSED DISCONNECT SWITCH'A' - DENOTES SWITCH SIZE

COMBINATION STARTER/DISCONNECT SWITCH'A' - DENOTES SWITCH SIZE'1' - DENOTES NEMA SWITCH SIZE

CIRCUIT BREAKER IN NEMA 1 ENCLOSURE'A' - DENOTES FRAME SIZE'B' - DENOTES TRIP SETTING

TRANSIENT VOLTAGE SUPPRESSOR

MOMENTARY CONTACT PUSHBUTTON SWITCH'P' - DENOTES PILOT LIGHT

MAINTAINED CONTACT EMERGENCY STOP & RESET PUSHBUTTON STATION

MOTORIZED DAMPER C/W DISCONNECT SWITCH

ELECTRIC CABINET HEATER

ELECTRIC HEATING COIL

ELECTRIC UNIT HEATER

FAN COIL UNIT

COMBINATION DAMPER, SMOKE AND FIRE

VARIABLE FREQUENCY DRIVE

SURFACE TYPE PANELBOARD

FLUSH (RECESSED) TYPE PANELBOARD

DISTRIBUTION PANEL

LIGHTING PANELBOARDBRANCH CIRCUIT: 600/347V

POWER PANELBOARDBRANCH CIRCUIT: 600/347V OU/OR 208/120V

LP

PP

RECEPTACLE PANELBOARDBRANCH CIRCUIT: 208/120VRP

LVRC LOW VOLTAGE RELAY CABINET

JB

PB

JUNCTION BOX (SCHEMATIC)

PULL BOX (SCHEMATIC)

CONDUIT RUN CONCEALED IN CEILING SPACE AND/OR IN WALLS

EMBEDDED/BURIED CONDUIT

LOW-PROFILE SURFACE MTD 2-CHANNEL RACEWAY, WITH OUTLETS SHOWN

LOW-PROFILE SURFACE MTD 3-CHANNEL RACEWAY, WITH OUTLETS SHOWN

WALL MOUNTED GROUND BUS BAR

CONDUIT & RACEWAY SYSTEMS

SECURITY & DOOR HARDWARE

PANELBOARDS & CABINETS

ABBREVIATIONSGENERAL

AFF ABOVE FINISHED FLOOR

BFG BELOW FINISHED GRADE

C/W COMPLETE WITH

IN INCHES

EC EXISTING ITEM TO REMAIN & BE RECIRCUITED

BOM BILL OF MATERIALS

MM MILLIMETERS

MTD MOUNTED

EX EXISTING ITEM TO REMAIN

ER EXISTING ITEM TO BE RELOCATED

EM EMERGENCY

DWG DRAWING

ATS AUTOMATIC TRANSFER SWITCH

MCC MOTOR CONTROL CENTRE

NIC NOT IN CONTRACT

NTS NOT TO SCALE

RL RELOCATED ITEM

STD STANDARD

SIM SIMILAR

TYP TYPICAL

BAS BUILDING AUTOMATION SYSTEM

BMS BUILDING MANAGEMENT SYSTEM

GND GROUND

CB CIRCUIT BREAKER

LCP LIGHTING CONTROL PANEL

LVR LOW VOLTAGE RELAY

MSP MOTOR STARTER PANEL

RCSP REMOTE CONTROL/SIGNAL PANEL

SB SWITCHBOARD

SG SWITCHGEAR

SS SUBSTATION

UPS UNINTERRUPTIBLE POWER SUPPLY

AWG AMERICAN WIRE GAUGE

WP WEATHERPROOF

BND BOND

C CONDUIT

TEM / EMT ELECTRICAL METALLIC TUBING

GFI GROUND FAULT INTERRUPTOR

P POLE

PH PHASE

TL TWIST-LOCK

W WIRE

AC AIR CONDITIONING

ACCU AIR COOLED CONDENSING UNIT

AHU AIR HANDLING UNIT

BB BYPASS BOX

CP CONDENSATE PUMP

CU CONDENSING UNIT

EF EXHAUST FAN

FPB FAN POWERED BOX

RTU ROOFTOP UNIT

VAV VARIABLE AIR VOLUME BOX

ER ELECTRIC RADIATOR

AV AUDIO VISUAL

FA FIRE ALARM

CM COFFEE MACHINE

COMM COMMUNICATIONS

DW DISHWASHER

REF REFRIGERATOR

CRAC COMPUTER ROOM AIR CONDITIONER

SBO SUPPLIED BY OTHERS, INSTALLED BY DIV. 26

ELECTRICAL

WIRING

MECHANICAL EQUIPMENT

MISCELLANEOUS

NOTES:

1. ABBREVIATIONS LIST IS FOR REFERENCE ONLY. NOT ALLABBREVIATIONS SHOWN ARE USED IN PROJECT.

1. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT MOUNTING HEIGHTS, FINISHES, DIMENSIONS ANDLOCATIONS OF DEVICES INCLUDING LIGHT FIXTURES, PRIOR TO COMMENCEMENT OF WORK. ANYDISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS AND/OR EXISTING CONDITIONS ARE TO BEPROMPTLY REFERRED TO ENGINEER FOR INSTRUCTIONS BEFORE ANY WORK COMMENCES.

2. INSTALLATION OF ELECTRICAL EQUIPMENT SHALL BE COMPLETED IN STRICT ACCORDANCE WITH THEMANUFACTURER'S RECOMMENDATIONS.

3. PROVIDE SEPARATE PRICES FOR SCOPE OF WORK, AS SHOWN. WHERE A SEPARATE PRICE IS INDICATED, THEENTIRE SCOPE OF WORK, INCLUDING PROVIDING ALL MATERIAL, AS WELL AS THE MEANS AND METHODS TOEXECUTE THE WORK AS GOVERNED BY THE GENERAL AND SPECIFIC CONDITIONS OF THE CONTRACT, IS TO BEINCLUDED IN THE SEPARATE PRICE BID SCOPE, INCLUDING ANY NECESSARY DEMOLITION AND RE-WORK, ASAPPLICABLE.

4. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT.

5. THE EXISTING SYSTEMS SHALL BE LEFT IN PERFECT WORKING ORDER UPON COMPLETION OF ALL NEW WORK.

6. CONTRACTOR SHALL PROVIDE AND CONNECT ALL RACEWAYS AND WIRING FROM EQUIPMENT, DEVICES ANDLIGHTING FIXTURES TO ITS SOURCE OF POWER AND CONTROLS.

7. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS OF FINISHED CONSTRUCTION PRIOR TO FABRICATION ANDINSTALLATION OF FIXTURES AND EQUIPMENT.

8. ELECTRICAL CONTRACTOR SHALL VERIFY SWITCHES, RECEPTACLES AND PLATE FINISHES WITH THE ARCHITECTBEFORE PERFORMING HIS INSTALLATION. ALL COVERPLATES SHALL BE AS SPECIFIED BY ARCHITECT.

9. EXISTING ELECTRICAL EQUIPMENT AND PANELBOARDS SHALL BE MODIFIED AS REQUIRED TO ACCOMMODATETHE WORK OF THIS CONTRACT. REPLACE EXISTING CIRCUIT BREAKERS IN PANELS WITH IDENTICAL NEWBREAKERS AS REQUIRED AND PROVIDE UPDATED TYPEWRITTEN DIRECTORIES.

10. COORDINATE LOCATION OF OUTLETS AND SWITCHES WITH FURNITURE AND EQUIPMENT LAYOUTS AND WITHOWNER'S REPRESENTATIVE.

11. ANY EXISTING WORK DAMAGED AS A RESULT OF PERFORMING THE WORK OF THIS CONTRACT SHALL BEREPAIRED OR REPLACED AS REQUIRED. MATERIAL AND FINISH TO MATCH EXISTING TO THE SATISFACTION OFTHE OWNER'S REPRESENTATIVE.

12. ALL ELECTRICAL WORK IN ADJOINING AREAS WHICH IS REQUIRED TO FUNCTION BUT IS AFFECTED BY THISWORK SHALL BE RECONNECTED AND RESTORED TO ITS PRESENT FUNCTION AS PART OF THE ELECTRICALSYSTEM OF THE BUILDING(S).

13. ALL BRANCH CIRCUIT WIRING SHALL BE RUN CONCEALED IN WALLS AND/OR ABOVE HUNG CEILING UNLESSOTHERWISE NOTED.

14. WIRING IN AIR PLENUM HUNG CEILINGS INSTALLED WITHOUT CONDUIT OR EMT SHALL BE TEFLON JACKETEDAND FT-6 RATED.

15. NO LOW VOLTAGE WIRING SHALL BE PERMITTED IN THE SAME RACEWAY AS POWER WIRING.

16. CONTRACTOR TO DE-RATE CONDUCTORS IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE WHENINSTALLING MORE THAN THREE (3) CIRCUITS IN A 3 4"C HOMERUN.

17. FOR WIRING IN EXISTING PARTITIONS WHERE EMT INSTALLATION IS IMPRACTICAL, FLEXIBLE GALVANIZED STEELCONDUIT SHALL BE ACCEPTED. COORDINATE EXACT SIZE WITH SPECIFIED CABLING REQUIREMENTS. MINIMUMSIZE USED SHALL BE 3 4".

18. PROVIDE NYLON PULL CORDS IN ALL EMPTY RACEWAYS.

19. ALL CONDUITS FOR BRANCH CIRCUITING AND/OR COMMUNICATIONS CABLING, INCLUDING THOSE RUN INCEILING OF FLOOR BELOW SHALL BE IDENTIFIED AT EVERY 50 FEET OF LENGTH AND AT EACH OUTLET AND PULLBOX WITH PANEL AND CIRCUIT NUMBER OR SYSTEM NAME.

20. CONTRACTOR SHALL PROVIDE AN EMPTY CONDUIT SYSTEM WITH NYLON PULL CORDS AND OUTLET BOXES FORINSTALLATION OF LOW TENSION WIRING SYSTEM. VERIFY EXACT REQUIREMENTS WITH SYSTEM VENDOR.

21. THE MINIMUM RATING OF DISCONNECT SWITCHES SHALL BE EQUAL TO OR GREATER THAN THE RATING OF THEPROTECTION DEVICE ON THE SUPPLY SIDE OF THE DISCONNECT SWITCH. MINIMUM DISCONNECT SWITCH SIZESHALL BE 30 AMPERES.

1. NOTES AND GRAPHIC REPRESENTATIONS SHALL NOT LIMIT THE EXTENT OF DEMOLITION REQUIRED.CONTRACTOR SHALL VISIT THE SITE, CAREFULLY EXAMINE EXISTING CONDITIONS AND SHALL PERFORM ALLDEMOLITION REQUIRED TO ACHIEVE THE FINAL DESIGN INTENT AS REQUIRED BY THE CONTRACT DOCUMENTS.EXTENT OF ALL DEMOLITION WORK SHALL BE COORDINATED WITH THE ARCHITECT.

2. EQUIPMENT INDICATED TO BE REMOVED SHALL BE TAKEN FROM THE SITE AND DISPOSED OF IN ACCORDANCEWITH APPLICABLE LAWS AND ENVIRONMENTAL REGULATIONS. LANDLORD SHALL HAVE THE OPTION TO RECEIVEANY ITEMS CALLED TO BE REMOVED PRIOR TO REMOVAL FROM SITE. EQUIPMENT REQUIRED TO BE TURNEDOVER TO THE OWNER SHALL BE PLACED IN A MUTUALLY ACCEPTABLE LOCATION.

3. THE WORK SHALL INCLUDE THE REMOVAL OF MATERIALS AS DIRECTED. PRIOR TO REMOVING EQUIPMENT ANDMATERIALS FROM THE PROJECT SITE, THE BUILDING MANAGER SHALL INSPECT AND ADVISE WHICH ITEMS WILLBE RESTORED.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL FROM THE PREMISES ALL DEBRIS RESULTING FROMREMOVAL OF WORK.

5. CONTRACTOR SHALL REMOVE BACK TO SOURCE ALL REMAINING SERVICES, AT ALL POINTS OFDISCONNECTION, UNLESS OTHERWISE INDICATED OR IMPRACTICAL DUE TO CONNECTION WITHEXISTING-TO-REMAIN SERVICES.

6. DEMOLITION AND OTHER WORK WHICH CREATES DISTURBING NOISE, MUST BE PERFORMED AFTER NORMALWORKING HOURS OR ON WEEKENDS. THE DELIVERY, HANDLING, AND INSTALLING OF MATERIALS, EQUIPMENTAND DEBRIS MUST BE ARRANGED TO AVOID ANY INCONVENIENCE AND ANNOYANCE TO OTHER TENANTS.CLEANING MUST BE CONTROLLED TO PREVENT DIRT AND DUST FROM INFILTRATING INTO ADJACENT TENANTOR ELECTRICAL AREAS. WELDING OR BUR.

7. CUT, PATCH, AND PAINT CEILINGS AND SLAB AS REQUIRED TO MATCH EXISTING CONDITIONS.

8. ALL POWER CONDUCTORS, CONTROL WIRING AND CONDUIT ASSOCIATED WITH MECHANICAL EQUIPMENT SUCHAS FANS, AIR CONDITIONING UNITS, PUMPS, ETC. DESIGNATED FOR REMOVAL ON THE HVAC AND PLUMBINGDEMOLITION DRAWINGS SHALL BE REMOVED BACK TO THE SOURCE OF POWER AND DISCONNECTED. ALLMOTOR STARTERS, DISCONNECT SWITCHES, CONTROL DEVICES, ETC. SHALL BE REMOVED. REFER TO HVACAND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.

9. EXISTING ELECTRICAL EQUIPMENT AND PANELBOARDS SHALL BE MODIFIED AS REQUIRED TO ACCOMMODATETHE WORK OF THIS CONTRACT. REPLACE EXISTING CIRCUIT BREAKERS IN PANELS WITH IDENTICAL NEWBREAKERS AS REQUIRED AND PROVIDE UPDATED TYPEWRITTEN DIRECTORIES.

10. THIS CONTRACTOR SHALL MAINTAIN CONTINUITY OF SERVICE TO EXISTING BUILDING FIRE ALARM SYSTEM.COORDINATE WITH BUILDING MANAGER.THE REMOVAL OF ALL FIRE ALARM, COMMUNICATIONS, DATA ANDSECURITY EQUIPMENT AND ASSOCIATED CABLING SHALL BE COORDINATED WITH BUILDING OPERATINGPERSONNEL. EXISTING BASE BUILDING FIRE ALARM SYSTEM SHALL REMAIN IN OPERATION DURING BOTHDEMOLITION AND CONSTRUCTION STAGES OF THIS PROJECT.

11. WHERE REMOVAL OF EXISTING ELECTRICAL EQUIPMENT WILL RESULT IN OUTAGES IN AREAS NOT TO BEDEMOLISHED, THE CONTRACTOR SHALL COORDINATE IN ADVANCE AND OBTAIN THE APPROVAL OF THEBUILDING MANAGER. PROVIDE MINIMUM SEVEN (7) DAY ADVANCE NOTICE.

12. WHERE PORTIONS OF AN EXISTING BRANCH CIRCUIT ARE REMOVED, WIRING TO REMAIN DEVICES ON THECIRCUIT SHALL BE RECONNECTED OR MODIFIED IN AN APPROVED MANNER AS REQUIRED TO MAINTAINCONTINUITY OF THE AFFECTED BRANCH CIRCUIT AND OPERATION OF THE REMAINING DEVICES.

13. FEEDERS AND BRANCH CIRCUITS TO BE REMOVED - CONDUIT AND SUPPORTS SHALL BE REMOVED TO THEPANEL OF ORIGIN OR THE BOUNDARY OF THE PROJECT AREA. WIRING SHALL BE REMOVED TO THE PANEL OFORIGIN. WHERE EMPTY CONDUITS REMAIN, INSTALL A PULL STRING AND IDENTIFY AT BOTH ENDS. FEEDERSAND BRANCH CIRCUITS TO BE RE-USED - REMOVE CONDUIT AND WIRING TO LOCATIONS WHICH AVOIDCONFLICTS WITH NEW WORK. INSTALL JUNCTION BOXES, TAPE OFF CONDUCTORS AND IDENTIFY WITH PANELAND CIRCUIT NUMBER.

1. THE CONTRACTOR SHALL VISIT THE PREMISES AND COMPARE SAME WITH A FULL SET OF BID DOCUMENTSBEFORE PROCEEDING WITH ANY WORK IN OCCUPIED AREAS, THE CONTRACTOR SHALL APPLY TO LANDLORDFOR PERMISSIONS TO ENTER SUCH AREAS. THE CONTRACTOR IS OBLIGATED TO PERFORM WORK ONLY ATTIMES DESIGNATED BY THE LANDLORD AND/OR TENANT. THERE WILL BE NO ADDITIONAL COMPENSATION FORTHE WORK PERFORMED PREMIUM TIME WITHOUT PRIOR WRITTEN APPROVAL.

2. CONTRACTOR SHALL COORDINATE THE WORK WITH ALL TRADES AND EXISTING CONDITIONS.

3. CONTRACTOR SHALL COORDINATE AND REVIEW SLAB PENETRATIONS WITH BUILDING STRUCTURALENGINEERS.

1. GENERAL1.1. CONTRACTOR SHALL FURNISH ALL REQUIRED CONDUITS, WIRING, AND JUNCTION BOXES TO ENERGIZE

EQUIPMENT INDICATED.1.2. CONTRACTOR SHALL COORDINATE ON SITE AND WITH THE ARCHITECT FOR THE EXACT LOCATION OF ALL

FLOOR AND WALL MOUNTED DEVICES PRIOR TO THE START OF ANY SUCH WORK.1.3. CONTRACTOR SHALL MAINTAIN CONTINUITY TO ALL EXISTING CIRCUITRY TO REMAIN WHICH ARE

AFFECTED BY THE SCOPE OF WORK. CONTRACTOR TO FURNISH AND INSTALL ALL NECESSARY WIRES,CONDUIT AND JUNCTION BOXES REQUIRED TO KEEP CONTINUITY.

1.4. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EQUIPMENT TO BE SUPPLIED BY OTHER TRADESAND INSTALLED AND/OR WIRED UNDER THIS SECTION.

2. POWER2.1. ALL BRANCH WIRING SHALL BE CONCEALED IN WALLS AND ABOVE HUNG CEILING.2.2. WHEN PULLING BACK WIRING AND/OR DEMOLISHING WALLS FOR INSTALLED EQUIPMENT, COORDINATE

WITH EXISTING MECHANICAL EQUIPMENT AND SERVICES AND TEMPORARILY RELOCATE EQUIPMENT ASNECESSARY.

2.3. ALL EXISTING ELECTRICAL EQUIPMENT AND DEVICES TO REMAIN IN ALL AREAS INDICATED AS OUTSIDE OFTHE PROJECT.

2.4. PROVIDE SEPARATE NEUTRAL WIRE FOR EACH DEDICATED CIRCUIT.2.5. VERIFY EXACT POWER REQUIREMENTS OF MECHANICAL EQUIPMENT BEFORE ROUGHING. REFER TO

MECHANICAL SHOP DRAWINGS FOR MANUFACTURERS ELECTRICAL DATA AND INSTALLATIONREQUIREMENTS. ADVISE CONSULTANT OF ANY DISCREPANCIES.

2.6. IDENTIFY AND LABEL ALL NEW OR RELOCATED POWER RECEPTACLES.2.7. WHERE WIRING DEVICES ARE INDICATED TO BE REMOVED AND RELOCATED, PROVIDE NEW WIRING DEVICE

BUT RELOCATE EXISTING CIRCUIT AND JUNCTION BOX AS REQUIRED.2.8. ELECTRICAL CONTRACTOR RESPONSIBLE FOR PROVIDING NEW CONDUIT AND INFRASTRUCTURE AS

REQUIRED FOR COMMUNICATIONS SYSTEMS IN ADDITION TO WORK SHOWN ON THIS DRAWING.ELECTRICAL CONTRACTOR IS TO REVIEW, COORDINATE AND CARRY THE SCOPE OF WORK AS SHOWN ONTHE COMMUNICATIONS DRAWINGS.

2.9. CONTRACTOR MUST PRACTICE PROPER LOCK OUT AND TAG OUT PROCEDURES.2.10. BEAM CLAMPS ARE NOT PERMITTED TO HANG OR SUPPORT ELECTRICAL SERVICES.2.11. CIRCUITS SHOWN ARE FOR GROUPING PURPOSES ONLY. CONTRACTOR TO VERIFY EXACT CIRCUIT

NUMBERS IN FIELD AND REUSE CIRCUITS FROM THE DEMOLITION PHASE TO FEED NEW/RELOCATEDEQUIPMENT. CONFIRM AVAILABILITY OF CIRCUITS PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR TOCARRY COST FOR QUANTITY OF BREAKERS EQUAL TO NEW CIRCUITS ON LAYOUT AS PART OF BID.PROVIDE 15A.1P CIRCUIT BREAKERS FOR NEW CIRCUITS U.O.N. EXTEND WIRING AND CONDUIT TO SUITFOR EXISTING-TO-REMAIN AND RELOCATED LOADS AS REQUIRED. A MAXIMUM OF FOUR (4) DUPLEXRECEPTACLES ALLOWED PER PANEL CIRCUIT. UPDATE ALL PANEL SCHEDULES UTILIZED FOR CIRCUITINGAS PART OF THIS PROJECT.

2.12. ALL WORK REQUIRING ELECTRICAL SHUTDOWN WHICH WILL AFFECT OTHER FLOORS OF THE BUILDING OREVEN AFFECT THE NORMAL CONTINUATION OF CONSTRUCTION WORK ON THESE FLOORS, SHALL BE DONEON OVERTIME HOURS, AND SHALL NOT DISTURB CONTINUITY OF ELECTRICAL SERVICE TO EXISTINGTENANTS ON THE AFFECTED FLOORS. COORDINATE SHUTDOWN REQUIREMENTS WITH BUILDINGMANAGEMENT PROVIDING A MINIMUM OF ONE WEEK ADVANCE NOTICE.

2.13. WHERE MULTIPLE SWITCHES AND RECEPTACLES ARE INDICATED AT THE SAME LOCATION, THEY SHALL BEMOUNTED BEHIND A COMMON FACEPLATE.

2.14. INCREASE THE SIZE OF BRANCH CIRCUIT CONDUCTORS AND HOME RUNS AS REQUIRED SO THAT THETOTAL VOLTAGE DROP, FROM PANELBOARDS TO LOADS, DOES NOT EXCEED 3% UNDER LOAD.

2.15. CONTRACTOR SHALL VERIFY THE EXACT CIRCUIT NUMBER IN THE FIELD, WHEN BRANCH CIRCUITS AREINDICATED TO BE CONNECTED TO EXISTING PANELBOARDS. REFER TO PANELBOARD DESIGNATIONLEGEND ON THIS DRAWING FOR PANELBOARD ABBREVIATIONS AND CORRESPONDING PANELBOARDNAMES.

2.16. UNDERFLOOR CONDUIT ROUTING SHOWN FOR DIAGRAMMATIC PURPOSES ONLY. CONTRACTOR SHALLCOORDINATE EXACT CONDUIT ROUTING IN THE FIELD AND WITH OTHER TRADES. PRIOR TO INSTALLATION,APPROVAL FOR ALL CONDUIT ROUTING IN THE SLAB OF THE FLOOR SHALL BE OBTAINED FROM THE BASEBUILDING STRUCTURAL ENGINEER AND BUILDING MANAGEMENT.

ELECTRICAL PROJECT NOTESGENERAL

COORDINATION

DEMOLITION

POWER & SYSTEMS

REMOVAL WORK

14. ALL WORK SHALL BE PROPERLY IDENTIFIED AFTER DEMOLITION. UPDATE ALL PANEL SCHEDULES TO REFLECTEQUIPMENT AND CIRCUIT REMOVALS.

15. WHERE EXISTING FLOOR MOUNTED DEVICE IS TO BE REMOVED, CONTRACTOR SHALL FILL EXISTING SLABPENETRATIONS WITH cUL LISTED AND APPROVED NON-SHRINKABLE WATERPROOF AND FIRESTOPPINGMATERIALS FLUSH TO FLOOR SLAB AND CAPPED.

DEMOLITION CONTINUED

1. GENERAL1.1. FOR EXACT LOCATION AND MOUNTING HEIGHTS OF ALL LIGHTING FIXTURES, SWITCHES AND JUNCTION

BOXES SEE ARCHITECTURAL DRAWINGS.1.2. CONTRACTOR SHALL VISIT THE SITE TO DETERMINE THE EXTENT OF THE ALL EXISTING CONDITIONS

PRIOR TO SUBMITTING ANY QUOTATION.1.3. ANY DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS AND/OR EXISTING CONDITIONS ARE TO

BE PROMPTLY REFERRED TO ENGINEER FOR INSTRUCTIONS BEFORE ANY WORK COMMENCES.1.4. CONTRACTOR SHALL FURNISH ALL REQUIRED CONDUIT, WIRE AND BOXES AS WELL AS CEILING OUTLETS

AND WHIPS TO ENERGIZE LIGHTING FIXTURES AS INDICATED.1.5. CONTRACTOR SHALL MAINTAIN CONTINUITY IN ALL EXISTING CIRCUITRY TO REMAIN WHICH IS AFFECTED

BY THE SCOPE OF WORK. CONTRACTOR TO FURNISH ALL NECESSARY WIRES, CONDUIT AND JUNCTIONBOXES REQUIRED TO KEEP CONTINUITY.

2. LIGHTING2.1. REVISE EXISTING LIGHTING WIRING TO ACCOMMODATE NEW LIGHTING LAYOUT. BALANCE THE LOADS.2.2. ALL LUMINAIRES SHALL BE INSTALLED ACCURATELY IN LINE & LEVEL.2.2. ANY RELOCATION OF LIGHTING LUMINAIRES REQUIRED DUE THE SITE CONDITIONS SHALL BE APPROVED

BY THE ENGINEER PRIOR TO PROCEEDING WITH WORK.2.3. ALL EXISTING LUMINAIRES WHICH ARE REMAINING OR TO BE RELOCATED, SHALL BE CLEANED,

RE-LAMPED & CHECKED FOR PROPER OPERATION, AS NECESSARY. ENSURE THEY ARE FULLYFUNCTIONAL BEFORE PLACING BACK INTO SERVICE.

2.4. ALL NEW OR RELOCATEDLUMINAIRES ARE TO BE CHAINED TO THE ABOVE CEILING FLOOR PAN.2.5. REFER TO ARCHITECTURE DRAWINGS FOR EXACT LUMINAIRE LENGTHS.

3. LIFE SAFETY SYSTEM3.1. REUSE EXISTING FIRE ALARM DEVICES. RELOCATE DEVICES AS INDICATED ON DRAWING. RE-VERIFY ALL

DEVICES IN THE SPACE.3.2. AFTER COMPLETION OF WORK THE FIRE ALARM SYSTEM MUST BE TESTED AND VERIFIED AS PER

STANDARD ULC S5373.3. EMERGENCY FIXTURE LOCATIONS ARE SHOWN AT DESIRED LOCATIONS. CONTRACTOR TO CONNECT TO

THE NEAREST EXISTING EMERGENCY LIGHTING CIRCUIT IN THE AREA. CONTRACTOR TO CONFIRM IFEXISTING CIRCUIT HAS ADEQUATE CAPACITY TO ACCOMMODATE NEW LIGHT FIXTURES.

3.4. ALL NEW FIRE ALARM DEVICES ARE TO BE LISTED FOR USE WITH EXISTING FIRE ALARM SYSTEM.3.5. COORDINATE TIE-IN OF NEW FIRE ALARM COMPONENTS AND DEVICES WITH BASE BUILDING FIRE ALARM

VENDOR.3.6. EXIT SIGNS ARE TO BE ILLUMINATED FOR A MINIMUM OF 30 MINUTES UPON LOSE OF POWER UNLESS

POWERED FROM A DESIGNATED EMERGENCY POWER SOURCE.

LIGHTING SYSTEMS

ELECTRICAL DRAWING LISTSHEET NUMBER SHEET TITLE ISSUED FOR ISSUE DATE

E-001 ELECTRICAL COVER PAGE ISSUED FOR TENDER 2020-02-03

E-101 ELECTRICAL SPECIFICATIONS SHEET 1 ISSUED FOR TENDER 2020-02-03

E-102 ELECTRICAL SPECIFICATIONS SHEET 2 ISSUED FOR TENDER 2020-02-03

E-311 POWER AND SYSTEMS NEW WORK PLAN ISSUED FOR TENDER 2020-02-03

E-401 LIGHTING DEMOLITION PLAN ISSUED FOR TENDER 2020-02-03

E-411 LIGHTING NEW WORK PLAN ISSUED FOR TENDER 2020-02-03

E-601 PANEL SCHEDULES ISSUED FOR TENDER 2020-02-03LC LIGHTING CONTROL HUB

www.loringengineers.com

LORING CONSULTING ENGINEERS, INC.

TEL. (647) 352-9999TORONTO, ON M4V 2Y7

55 ST. CLAIR AVE. W, SUITE 201

NEW YORK, NY ● WASHINGTON, DC ● PRINCETON, NJ ● DURHAM, NC ● TORONTO, ON

Checked:

DRAWINGS ARE NOT TO BE SCALED.

CONSTRUCTION MUST CONFIRM TO ALL APPLICABLE CODESAND REQUIREMENTS OF THE AUTHORITIES HAVINGJURISDICTION.

CONTRACTOR MUST VERIFY AND ACCEPT RESPONSIBILITYFOR ALL DIMENSIONS AND CONDITIONS ON SITE AND SHALLNOTIFY THE APPROPRIATE CONSULTANT OF DISCREPANCIESWITH OR VARIATIONS FROM THE INFORMATION PROVIDEDBEFORE PROCEEDING WITH THE WORK.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTIONUNLESS SPECIFICALLY ISSUED "FOR CONSTRUCTION" OROTHERWISE CONFORMING TO THE DRAWINGS THAT FORM THEBASIS FOR WHICH A BUILDING PERMIT FOR THE PROJECT HASBEEN ISSUED.

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTSARE THE COPYRIGHT PROPERTY OF THE ARCHITECT ANDMUST BE RETURNED UPON REQUEST. REPRODUCTION OFDRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS INPART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECT'SWRITTEN PERMISSION.

N O T E S

11407

Entered:

Plot:

HIGHLAND HALLSHELL SPACE INTERIOR RETROFIT(UTSC PROJECT 2019-11)

UNIVERSITY OF TORONTO SCARBOROUGH1265 MILITARY TRAIL, TORONTO ON, M1C 1A4

ProjectNorth

2019-09-12Project No:

REF DATE DESCRIPTION

A 2019/09/13 ISSUED FOR 100%DD

B 2019/12/02 ISSUED FOR COORDINATION

C 2019/12/03 ISSUED FOR 99% REVIEW

D 2019/12/11 ISSUED FOR PERMIT

E 2020/02/03 ISSUED FOR TENDER

ELECTRICALCOVER PAGE

JFRAS

E-001

Page 2: E-601 PANEL SCHEDULES · ceiling mtd occupancy sensor c/w appropriate switch pack. 'a' - denotes switch designation ... electric heating coil electric unit heater fan coil unit combination

ELECTRICAL SPECIFICATIONS

1. CODES AND STANDARDS

1.1. DESIGN AND PERFORMANCE OF COMPONENTS AND METHODS SPECIFIED HEREIN SHALL COMPLY WITH THEAPPLICABLE PROVISIONS OF THE CODES, STANDARDS, AND MANUFACTURER'S RECOMMENDATIONS OF THEENTITIES LISTED BELOW:

OBC ONTARIO BUILDING CODE

OESC ONTARIO ELECTRICAL SAFETY CODE

CSA CANADIAN STANDARDS ASSOCIATION

ULC UNDERWRITER'S LABORATORIES OF CANADA

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION,

AND ALL AGENCIES HAVING JURISDICTION.

1.2. COMPLY WITH ELECTRICAL AND BUILDING CODE BULLETINS IN FORCE AT TIME OF BID SUBMISSION.

1.3. ALL ELECTRICAL WORK SHALL BE PERFORMED IN COMPLIANCE WITH BASE BUILDING STANDARDS ANDLANDLORD'S REQUIREMENTS.

2. SCOPE OF WORK

2.1. THE SCOPE OF WORK SHALL CONSIST OF THE FOLLOWING:

2.1.1. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED FOR COMPLETE INSTALLATION OFALL WORK INDICATED ON THE DRAWINGS OR SPECIFIED HEREIN.

2.1.2. SUPPLYING, INSTALLING AND CONNECTING ALL PANELBOARDS, FEEDERS, POWER OUTLETS, LIGHT FIXTURES,SWITCHES, CONTROLS, CONDUITS, AND WIRING.

2.1.3. SUPPLYING AND INSTALLING NEW TELEPHONE/COMMUNICATION OUTLETS AND RACEWAY.

2.1.4. SUPPLYING AND INSTALLING NEW CIRCUIT BREAKERS.

2.1.5. OTHER WORK SHOWN ON DRAWING AND INDICATED IN SPECIFICATIONS.

2.1.6. ELECTRICAL CONNECTIONS TO EQUIPMENT, MOTORS, ETC. FURNISHED BY THE OWNER AND/OR OTHERTRADES.

2.1.7. CONTRACTOR SHALL MAINTAIN CONTINUITY TO ALL EXISTING CIRCUITRY TO REMAIN WHICH ARE AFFECTED BYTHE SCOPE OF WORK. CONTRACTOR TO FURNISH AND INSTALL ALL NECESSARY WIRES, CONDUIT ANDJUNCTION BOXES REQUIRED TO MAINTAIN CONTINUITY.

2.2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND APPROVALS AND SHALL PAY ALLASSOCIATED COSTS AND FEES.

2.3. SUBMIT TO THE LOCAL ELECTRICAL INSPECTION DEPARTMENT, THE NECESSARY NUMBER OF DOCUMENTS FOREXAMINATION, SPECIAL INSPECTION AND APPROVAL, PRIOR TO THE COMMENCEMENT OF THE WORK, AND PAY ALLCOSTS AND ASSOCIATED FEES.

2.4. PROVIDE CERTIFICATE(S) OF ACCEPTANCE FOR THE AUTHORITIES INSPECTION DEPARTMENT, UPON COMPLETIONOF WORK.

2.5. VERIFY EXISTING CONDITIONS IN FIELD AND INCLUDE IN THE BID PRICE ALL WORK REQUIRED TO ACCOMMODATETHE EXISTING INSTALLATION.

2.6. PROVIDE AND MAINTAIN INSURANCE TO PROTECT THE OWNERS AND TRADES FROM ALL POSSIBLE CLAIMS.SUBMIT WITH BID FOR AN AMOUNT ACCEPTABLE TO OWNER AND GENERAL CONTRACTOR.

2.7. PROVIDE TEMPORARY LIGHT AND POWER SYSTEM (AS PART OF THE CONTRACT) ADEQUATE FOR THEREQUIREMENTS OF ALL TRADES DURING CONSTRUCTION. TEMPORARY SYSTEM SHALL BE DISCONNECTED ANDREMOVED WHEN PERMANENT SERVICE IS IN OPERATION.

3. NOTICE TO BIDDERS

3.1. THE SPECIFICATIONS AND DRAWINGS ARE INTENDED TO SERVE JOINTLY AS A BASIS UPON WHICH THE CONTRACTORSHALL SUBMIT A CONTRACT PRICE FOR THE MATERIAL AND LABOUR PROVISIONS.

3.2. WHEN CONFLICTS OCCUR IN THE SPECIFICATIONS OR ON THE DRAWINGS, OR BETWEEN EITHER, THE ITEMSGREATER QUANTITY OR HIGHER COST SHALL BE PROVIDED.

3.3. THE CONTRACTOR SHALL PROVIDE ALL ITEMS OF LABOUR OR MATERIALS SPECIFICALLY INDICATED, OR REQUIREDTO COMPLETE THE INTENDED INSTALLATIONS.

3.4. THE CONTRACTOR SHALL COORDINATE THE WORK SUCH THAT CONFLICTS IN SPACE LOCATIONS DO NOT OCCUR.

3.5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE WORK WITH ITS COMPLETION AND FINAL ACCEPTANCE, ANDSHALL REPLACE ANY OF SAME WHICH MAY BE DAMAGED, LOST OR STOLEN, WITHOUT ADDITIONAL COSTS TO THEOWNER.

3.6. ALL WORK IN OCCUPIED AREAS SHALL BE PERFORMED OUTSIDE NORMAL WORKING HOURS OR SCHEDULED ASDIRECTED BY THE BUILDING MANAGEMENT.

3.7. THE CONTRACTOR SHALL PRICE THE WORK BASED ON ANY NECESSARY MODIFICATIONS OF THE EXISTINGSYSTEMS. CONTRACTOR SHALL INCLUDE ALL NECESSARY OVERTIME WORK.

3.8. THE CONTRACTOR WILL BE HELD TO HAVE VISITED THE SITE AND EXAMINED THE DRAWINGS AND SPECIFICATIONSOF OTHER TRADES AND OF GENERAL CONSTRUCTION TRADES TO SATISFY ALL CONDITIONS INVOLVED. THECONTRACTOR SHALL VERIFY ALL MEASUREMENTS GIVEN ON THE DRAWINGS AND THOROUGHLY BE ACQUAINTEDWITH ALL EXISTING CONDITIONS AFFECTING THE PROPER INSTALLATION OF THE WORK.

4. SUBMITTALS AND COORDINATION

4.1. ALL SUBMITTALS SHALL BE EMAILED TO [email protected].

4.2. CONTRACTOR TO PROVIDE SHOP DRAWING SCHEDULE TO ARCHITECT AND ENGINEER AT AWARD OF CONTRACT.

4.2.1. SUBMIT THE FOLLOWING INFORMATION AS APPLICABLE AND AS REQUIRED FOR ALL WORK SPECIFIED UNDERTHIS DIVISION:

4.2.2. MANUFACTURERS' PRODUCT DATA SHEETS AND SAMPLES WHERE REQUIRED.

4.2.3. SUBMIT TWO (2) COPIES OF SHOP DRAWINGS OF ALL SPECIFIED EQUIPMENT INCLUDING DIMENSIONEDEQUIPMENT LAYOUTS FOR REVIEW AND RECORDS PRIOR TO COMMENCEMENT OF WORK. EACH SHOPDRAWING SHALL BE CHECKED AND STAMPED BY THE ELECTRICAL AND GENERAL CONTRACTOR PRIOR TOSUBMISSION TO THE ENGINEER FOR REVIEW.

4.2.4. POINT-TO-POINT WIRING DIAGRAMS AND SEQUENCES OF OPERATION.

4.2.5. REPRODUCIBLE DRAWINGS, PDF, OR AUTOCAD FILES.

4.2.6. OPERATION AND MAINTENANCE MANUALS.

4.2.7. CERTIFIED FACTORY AND FIELD TEST REPORTS.

4.2.8. MANUFACTURERS' CERTIFICATIONS, WARRANTIES AND SPARE PARTS.

4.3. SUBSTITUTIONS TO SPECIFIED ITEMS MUST COMPLY WITH ALL SPECIFICATION REQUIREMENTS AND WILL ONLY BEPERMITTED WHERE SUBMITTED AND APPROVED IN WRITING.

4.4. PROJECT CLOSEOUT

4.4.1. AFTER COMPLETION OF PROJECT AND PRIOR TO REQUESTING FINAL PAYMENT, THE CONTRACTOR SHALLGIVEN WRITTEN NOTICE THAT THE FOLLOWING ITEMS HAVE BEEN COMPLETED:

4.4.1.1. REQUIRED AGENCY APPROVALS.

4.4.2. COPY OF FINAL HYDRO INSPECTION CERTIFICATE. FIRE ALARM VERIFICATION CERTIFICATE (AS PER STANDARD

ULC 537) MUST BE PROVIDED WHEN THE FIRE ALARM SYSTEM WAS MODIFIED UNDER THE CONTRACT.

4.4.3. FINAL CLEANING AND ADJUSTMENT OF LIGHTING FIXTURES AND EQUIPMENT.

4.4.4. RESOLUTION OF OUTSTANDING SUBMITTALS AND PUNCH LIST ITEMS.

4.4.5. AS-BUILT DRAWINGS.

4.4.6. TURNOVER OF SPARE LAMPS, KEYS, AND ANY REQUIRED SPARE PARTS OR TOOLS.

4.4.7. SYSTEM STARTUP, TESTING AND ADJUSTMENT.

4.4.8. MANUFACTURER'S CERTIFICATIONS, WARRANTIES AND O&M MANUALS.

4.4.9. DEMONSTRATIONS AND OWNER INSTRUCTION.

5. AS-BUILT DRAWINGS AND MAINTENANCE MANUALS

5.1. CONTRACTOR SHALL KEEP RECORD OF ALL CHANGES, FIELD CONDITIONS, AND SHALL PREPARE AND PROVIDEAS-BUILT DRAWINGS INDICATING ANY DEVIATION FROM THE ORIGINAL ELECTRICAL DESIGN. THE REVISED DRAWINGSHALL BE STAMPED "AS-BUILT" WITH THE DATE AND CONTRACTOR'S SIGNATURE. ONE (1) SET OF PRINTS AND ACOMPACT DISK CONTAINING AUTOCAD FILES SHALL BE DELIVERED TO THE ENGINEER BEFORE FINAL PAYMENT ISMADE. AFTER REVIEW AND APPROVAL OF AS-BUILT CONTRACTOR SHALL DELIVER COMPACT DISK TO THE OWNER.CONTRACTOR SHALL PROVIDE TWO (2) PRINTS AND A COMPACT DISK OF AS-BUILT DRAWINGS TO THE BUILDINGMANAGER UPON COMPLETION OF WORK.

5.2. PROVIDE TO THE ARCHITECT THREE (3) BOUND AND INDEXED COPIES OF OPERATIONS AND MAINTENANCE DATAMANUALS FOR THE INSTALLATION. THE MANUAL SHALL PROVIDE COMPREHENSIVE DETAILED INFORMATION ONTHE APPROVED INSTALLATION, OPERATION AND USE, MAINTENANCE AND PARTS LIST. INCLUDE THE FOLLOWINGINFORMATION:

5.2.1. NAMES AND ADDRESS OF LOCAL SUPPLIERS FOR THE ITEMS INCLUDED; TECHNICAL DATA, PRODUCT DATA,SUPPLEMENTED BY BULLETINS, COMPONENT ILLUSTRATIONS, EXPLODED VIEW, TECHNICAL DESCRIPTIONS OFITEMS AND PARTS LISTS. ADVERTISING OR SALES LITERATURE IS NOT ACCEPTABLE.

5.2.2. THE CONSULTANT REVIEWED SHOP DRAWINGS

5.2.3. CERTIFICATE(S) OF ACCEPTANCE FROM THE AUTHORITIES INSPECTION DEPARTMENT.

5.2.4. VERIFICATION REPORTS AND CERTIFICATE(S) FOR ANY NEW FIRE ALARM COMPONENTS OR TIE-INS AND ANYBASE BUILDING TIE-INS FOR MISCELLANEOUS SYSTEMS (I.E. SECURITY, LIGHTING, CONTROL, DIGITALMETERING).

5.2.5. LOAD BALANCE REPORT WRITTEN GUARANTEE

5.3. REVIEW INFORMATION PROVIDED IN THE MAINTENANCE INSTRUCTIONS AND MANUALS WITH THE TENANT'SOPERATING PERSONNEL AND LANDLORD'S OPERATING PERSONNEL WHERE BASE BUILDING SYSTEMS AREREVISED TO ENSURE A COMPLETE UNDERSTANDING OF THE ELECTRICAL EQUIPMENT AND SYSTEMS AND THEIROPERATION.

6. QUALITY ASSURANCE

6.1. MATERIALS, EQUIPMENT AND INSTALLATION SHALL CONFORM TO THE LATEST EDITION OF ALL APPLICABLE CODESAND THE REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION. ALL WORK SHALL BE PERFORMED IN STRICTACCORDANCE WITH THE BUILDING STANDARDS AND THE REQUIREMENTS OF THE LOCAL UTILITY COMPANY.

6.2. MATERIALS, EQUIPMENT AND INSTALLATION SHALL CONFORM TO THE LATEST EDITION OF THE APPLICABLEREFERENCE STANDARDS AS PER SPECIFICATION SECTION 1.

6.3. THE CONTRACTOR SHALL HAVE COMPLETED AT LEAST TWO PROJECTS OF SIZE AND COMPLEXITY SIMILAR TOTHOSE REQUIRED UNDER THIS CONTRACT. ALL WORKMEN SHALL BE SKILLED IN THEIR RESPECTIVE TRADE.

6.4. ALL WORK SHALL BE WARRANTED IN WRITING TO BE FREE FROM DEFECTS IN MATERIALS AND/OR WORKMANSHIPFOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER. WARRANTY SHALL INCLUDEALL COSTS OF PARTS, LABOR, TRAVEL AND LIVING EXPENSES REQUIRED TO REPAIR OR REPLACE DEFECTIVEITEMS.

6.5. INSPECTION:

6.5.1. ALL STAGES OF THE INSTALLATION WILL BE INSPECTED BY THE OWNER AND/OR OWNERS REPRESENTATIVEFOR COMPLIANCE WITH THE REQUIREMENTS OF THE CONTRACT DRAWINGS AND SPECIFICATIONS. ANYPORTION OF THE CONSTRUCTION NOT MEETING THOSE REQUIREMENTS TO THE SATISFACTION OF THEENGINEER SHALL BE REPLACED AT NO ADDITIONAL COST TO THE OWNER.

6.5.2. PROVIDE PROPER EQUIPMENT AND REASONABLE ASSISTANCE AS THE OWNER AND/OR OWNERSREPRESENTATIVE MAY REQUIRE TO FACILITATE ACCESS AND INSPECTION AT THE CONSTRUCTION SITE.

7. REMOVALS

7.1. NOTES AND GRAPHIC REPRESENTATIONS ON THE DRAWINGS SHALL NOT LIMIT THE EXTENT OF REMOVALSREQUIRED. THE CONTRACTOR SHALL VISIT THE SITE AND CAREFULLY EXAMINE EXISTING CONDITIONS AND SHALLPERFORM ALL WORK REQUIRED TO ACHIEVE THE FINAL DESIGN INTENT AS REQUIRED BY THE CONTRACTDOCUMENTS. THE EXTENT OF ALL REMOVAL WORK SHALL BE COORDINATED WITH THE ARCHITECT.

7.2. WHERE PORTIONS OF AN EXISTING BRANCH CIRCUIT ARE REMOVED, WIRING TO REMAIN DEVICES ON THE CIRCUITSHALL BE RECONNECTED OR MODIFIED IN AN APPROVED MANNER AS REQUIRED TO MAINTAIN CONTINUITY OF THEAFFECTED BRANCH CIRCUIT AND OPERATION OF THE REMAINING DEVICES.

7.3. ALL WORK REQUIRED TO REMAIN IN SERVICE BUT INTERFERING WITH THE ALTERATION SHALL BE RELOCATED ANDRECONNECTED USING MATERIALS AND STANDARDS OF THIS CONTRACT.

7.4. THE REMOVAL OF ALL TELEPHONE AND DATA DEVICES AND ASSOCIATED CABLE SHALL BE COORDINATED WITHTHE APPROPRIATE BUILDING OPERATING PERSONNEL.

7.5. IN THE PROCESS OF REMOVING WIRING DEVICES, LIGHTING FIXTURES AND OTHER ELECTRICAL EQUIPMENT ANDMATERIALS, THIS CONTRACTOR SHALL EXERCISE EXTREME CAUTION TO PREVENT DAMAGE TO ARCHITECTURALSURFACES AND MATERIALS WHICH ARE TO REMAIN, INCLUDING WALLS, FLOORS, CEILINGS, WINDOWS, DOORS,MOLDINGS, STRUCTURAL MEMBERS, ETC. THE COST TO REPAIR OR REPLACE ANY MATERIAL DEEMED BY THEARCHITECT TO HAVE BEEN UNDULY DAMAGED BY THIS CONTRACTOR DURING DEMOLITION OR CONSTRUCTIONSHALL BE PAID BY THIS CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.

8. VALUATION OF CHANGES

8.1. PROVIDE A COMPLETE BREAKDOWN OF MATERIAL, LABOUR, OVERHEAD, PROFIT, ETC. WHEN SUBMITTINGQUOTATIONS FOR CHANGE NOTICES ON THIS PROJECT.

8.2. THE HOURLY LABOUR RATE SHALL BE INCLUSIVE OF ALL CHARGES FOR SUPERVISION, VARIABLE LABOURFACTORS, HAND TOOLS, PAYROLL BURDENS, HEIGHT FACTORS, WARRANTIES, STORAGE, RENTALS, ADDITIONALBONDING, PARKING, CLEAN-UP, AS-BUILT DRAWINGS, HOISTING, FREIGHT AND DELIVERY, BUT EXCLUSIVE OFOVERHEAD AND PROFIT.

9. BASIC MATERIAL AND METHODS

9.1. COORDINATE ALL WORK WITH THE WORK OF OTHER TRADES PRIOR TO INSTALLATION. ASSIST IN THE PREPARATIONOF COORDINATION DRAWINGS AS REQUIRED BY THE GENERAL CONDITIONS.

9.2. ALL SHUTDOWN OF BUILDING POWER, FIRE ALARM AND SIGNAL SYSTEMS SHALL BE COORDINATED WITH BUILDINGOPERATING PERSONNEL. WORK TO ACCOMMODATE OFF-HOUR SHUTDOWNS SHALL BE PERFORMED AT NOADDITIONAL COST TO THE OWNER.

9.3. CUT AND PATCH NONSTRUCTURAL SURFACES AS REQUIRED. REPAIRS SHALL MATCH ORIGINAL FINISH;PENETRATIONS OF FIRE RATED PARTITIONS SHALL BE SEALED WITH APPROVED MATERIAL TO PROVIDE THE SAMERATING AS THE PARTITION. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIRE RATED PARTITIONS.

9.4. PROVIDE EXPANSION FITTINGS WHERE RACEWAYS CROSS BUILDING EXPANSION JOINTS.

9.5. EQUIPMENT, DEVICES AND ENCLOSURES SHALL BE RATED NEMA 1 FOR INTERIOR LOCATIONS, NEMA 3R FOR DAMPLOCATIONS AND NEMA 4 FOR WET LOCATIONS.

9.6. PROVIDE 4" HIGH SEALED CONCRETE HOUSEKEEPING PADS BELOW ALL FLOOR MOUNTED EQUIPMENT ANDAROUND ALL CONDUITS PENETRATING FLOORS OF MECHANICAL EQUIPMENT ROOMS.

10. DELIVERY, STORAGE AND HANDLING

10.1. ALL EQUIPMENT SHALL BE DELIVERED IN MANUFACTURER'S ORIGINAL PROTECTIVE PACKAGING AND STORED IN A

CLEAN, DRY PLACE PROTECTED FROM WEATHER, FUMES, WATER, DUST AND PHYSICAL DAMAGE. TOUCH UPDAMAGED FINISHES TO MATCH THE ORIGINAL FINISH.

11. RACEWAYS

11.1. RIGID GALVANIZED STEEL (RGS) CONDUIT SHALL CONFORM TO CSA C22.2 NO 45. FITTINGS SHALL BE THREADED.

11.2. ELECTRICAL METALLIC TUBING (EMT) SHALL CONFORM TO CSA C22.2 NO.83. FITTINGS SHALL BE STEEL GLAND ANDRING COMPRESSION TYPE.

11.3. FLEXIBLE METALLIC CONDUIT SHALL CONFORM TO CSA C22.2 NO.56. LIQUID TIGHT FLEXIBLE METAL CONDUITSHALL CONFORM TO CSA C22.2 NO.56. FITTINGS SHALL BE STEEL.

11.4. PVC TELECOMMUNICATION AND TV CABLE DUCTS SHALL BE MANUFACTURED TO CSA B196.3.

11.5. ALL CONDUIT FITTINGS AND CONNECTORS SHALL BE STEEL WITH INSULATED THROATS TO CAN/CSA C22.2 NO.18.DIE-FORMED ZINC FITTINGS ARE NOT ACCEPTABLE. BUSHINGS SHALL BE PROVIDED AT ALL CONDUITTERMINATIONS. BUSHINGS LARGER THAN 1" (27MM) SHALL BE GROUNDING TYPE. PVC BUSHINGS MAY BE UTILIZEDONLY FOR 3/4" (21MM) BRANCH CIRCUIT CONDUITS TERMINATING AT PANELBOARDS.

11.6. MINIMUM RACEWAY SIZE SHALL BE 3/4" (21MM). RACEWAYS SHALL BE RUN PARALLEL TO BUILDING STRUCTURALLINES. RACEWAYS SHALL NOT BE RUN HORIZONTALLY BELOW 8'-0" AFF IN PARTITIONS. ALL EMPTY RACEWAYSSHALL BE FURNISHED WITH A 200LB TEST NYLON DRAG LINE.

11.7. ALL WIRING BETWEEN JUNCTION BOXES AND FOR CIRCUIT HOMERUNS BETWEEN FIRST OUTLET SERVED BY THEBRANCH CIRCUIT AND THE PANELBOARD SHALL BE RUN IN EMT OR RGS AS REQUIRED.

11.8. RACEWAY UTILIZATION SHALL BE AS FOLLOWS:

11.8.1.RIGID GALVANIZED STEEL (RGS) - IN CONCRETE SLABS; EXPOSED IN ALL MECHANICAL EQUIPMENT ROOMS;FIRE ALARM SYSTEMS.

11.8.2.ELECTRICAL METALLIC TUBING (EMT) - INTERIOR CONCEALED AND EXPOSED LOCATIONS; EXPOSED INMECHANICAL ROOMS ABOVE 8'-0" AFF; INTERIOR COMMUNICATIONS WIRING.

11.8.3.FLEXIBLE METALLIC CONDUIT - FINAL CONNECTIONS TO TRANSFORMERS (MAXIMUM LENGTH 3'-0") ANDLIGHTING FIXTURES IN INTERIOR LOCATIONS (MIN. LENGTH 18", MAXIMUM LENGTH 6'-0"); WHERE APPROVED BYTHE ENGINEER.

11.8.4.LIQUID TIGHT FLEXIBLE CONDUIT - FINAL CONNECTIONS TO MOTORS AND MECHANICAL EQUIPMENT.

11.8.5.MC CABLE - FINAL CONNECTIONS ONLY FROM JUNCTION BOXES ABOVE CEILINGS TO RECEPTACLES AND LIGHTFIXTURES (MAXIMUM LENGTH 10'-0" (3.048M). NOT TO BE USED FOR HOMERUNS OR FEEDERS TO MECHANICALEQUIPMENT INSTALL CONDUIT TO CSA C22.1.

11.9. INSTALL CONDUIT TO CSA C22.1.

11.10. ALL CONDUIT AND TUBING SHALL BE CUT SQUARE AND REAMED AT THE ENDS.

11.11. CONDUIT AND TUBING RUNS SHALL BE MECHANICALLY AND ELECTRICALLY CONTINUOUS FROM SERVICESTARTING TO ALL OUTLETS AND EQUIPMENT. CONDUIT SHALL ENTER AND BE SECURELY CONNECTED TO ACABINET, JUNCTION BOX, PILLBOX OR OUTLET BOX BY MEANS OF LOCKNUTS ON THE OUTSIDE AND INSIDE AND ANINSULATED BUSHING ON THE INSIDE. IN TUBING OR FLEXIBLE METAL CONDUIT THE ONE COMPRESSION LOCKNUTSHALL BE MADE WRENCH-TIGHT. ALL LOCKNUTS SHALL BE THE BONDING TYPE WITH SHARP EDGES FOR DIGGINGINTO THE METAL WALL OF AN ENCLOSURE AND SHALL BE INSTALLED IN A MANNER THAT WILL ASSURE A LOCKINGAND ELECTRICALLY CONTINUOUS INSTALLATION. LOCKNUTS AND BUSHINGS ARE NOT REQUIRED WHERECONDUITS ARE SCREWED INTO TAPPED CONNECTIONS. FOR ECCENTRIC AND CONCENTRIC KNOCKOUTS, PROVIDEGROUND RINGS.

11.12. ALL VERTICAL RUNS OF CONDUIT OR TUBING TERMINATING IN THE BOTTOMS OF WALL BOXES OR CABINETS, ORSIMILAR LOCATIONS, SHALL BE PROTECTED FROM THE ENTRANCE OF FOREIGN MATERIAL PRIOR TO THEINSTALLATION OF CONDUCTORS.

11.13. UNLESS OTHERWISE SPECIFIED, ALL CONDUIT AND TUBING SHALL BE INSTALLED CONCEALED. IN GENERAL, ALLCONDUIT AND TUBING SHALL BE RUN IN HUNG CEILINGS AND FURRED SPACES WHERE THEY EXIST. WHERECONDUIT IS RUN EXPOSED IT SHALL BE SECURELY SUPPORTED WITH ZINC COATED MALLEABLE IRON PIPE STRAPSOR OTHER APPROVED MEANS. ALL CONDUITS SHALL BE SUPPORTED FROM STRUCTURAL MEMBERS.

11.14. EVERY CONDUIT SYSTEM SHALL BE INSTALLED COMPLETE BEFORE ANY CONDUCTORS ARE DRAWN IN. WIREPULLING LUBRICANTS, WHEN UTILIZED, SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF UNDERWRITERS'LABORATORIES, INC., APPLICABLE TO THE SPECIFIC CONDUCTOR OR CABLE INSULATION AND RACEWAY MATERIAL.

11.15. SIZE ALL CONDUITS FOR A MAX. 40% FILL. TO INCLUDE DEDICATED INSULATED GROUND WIRE.

11.16. RUN CONDUITS IN WEBBED PORTION OF STRUCTURAL STEEL.

11.17. WHERE REQUIRED BY THE ENGINEER, EXTRA DEEP OR EXTRA SHALLOW OUTLET BOXES SHALL BE USED TOFACILITATE THE INSTALLATION OF THE CONDUIT SYSTEM.

12. BOXES

12.1. OUTLET, PULL AND JUNCTION BOXES SHALL BE FABRICATED FROM WELDED STEEL AND CONFORM TO CSA-C22.2 NO.18 AND NEMA OS1. BOXES FOR INTERIOR LOCATIONS SHALL BE CODE GAUGE, GALVANIZED SHEET STEEL. BOXESFOR MECHANICAL ROOMS SHALL BE CAST STEEL WITH GASKETED COVERS.

12.2. BOXES SHALL CONTAIN SUITABLE KNOCKOUTS. BARRIERS SHALL BE FURNISHED AS REQUIRED BY CODE AND TOSEPARATE SWITCHES FOR 347-VOLT CIRCUITS ON DIFFERENT PHASES.

12.3. BOXES SHALL BE SIZED AS REQUIRED BY CODE FOR NUMBER AND GAUGE OF CONDUCTORS THEREIN, EXCEPTWHERE NOTED TO BE LARGER, THE MINIMUM BOX SHALL BE 4" SQUARE BY 1-1/2" DEEP. COVERS GREATER THAN50LB SHALL BE DIVIDED INTO MULTIPLE SECTIONS.

12.4. WIREWAYS AND AUXILIARY GUTTERS SHALL BE TWO-PIECE STEEL CONSTRUCTION WITH ANSI 61 GRAY ENAMELFINISH. COVERS SHALL BE COMBINATION HINGED AND SCREW-ON TYPE. HOUSINGS SHALL HAVE REGULARLYSPACED KNOCKOUTS FOR CONDUIT ENTRY. WIREWAYS SHALL BE MANUFACTURED BY SQUARE D OR APPROVEDEQUAL. PROVIDE ALL END PIECES, CONNECTORS AND REQUIRED ACCESSORIES.

13. FASTENERS

13.1. PROVIDE INSERTS, EXPANSION SHIELD LUGS, ANCHORS, BOLTS WITH NUTS AND WASHERS, SHIMS OR ANY OTHERTYPE OF FASTENING DEVICES REQUIRED TO FASTEN PANELS OR OTHER EQUIPMENT TO FLOORS, WALLS ORCEILINGS. UNLESS OTHERWISE SPECIFIED HEREIN OR SHOWN ON THE CONTRACT DRAWINGS, ALL FASTENERSSHALL BE HOT-DIPPED GALVANIZED, OF SIZES AND TYPES RECOMMENDED BY THE EQUIPMENT MANUFACTURER ANDAS APPROVED BY THE ENGINEER.

14. WIRES, CABLES, SPLICES AND TERMINATIONS

14.1. POWER AND CONTROL WIRING SHALL BE COPPER, MINIMUM 98% CONDUCTIVITY, WITH TYPE RW90 INSULATIONRATED 600 VOLTS. MINIMUM WIRE SIZE SHALL BE #12 AWG. CONDUCTORS SHALL BE SOLID FOR WIRE SIZED #10 AWGAND SMALLER AND STRANDED FOR WIRE SIZES #8 AWG AND LARGER.

14.2. ALL HOME RUNS TO BE IN EMT CONDUIT.

14.3. MC CABLE SHALL BE 90°C RATED CODE TYPE MC90. JACKET SHALL BE ALUMINUM INTERLOCKING ARMOR. MCCABLE #12 MAY BE USED IN CEILING SPACE FROM CEILING DISTRIBUTION BOX DOWN TO RECEPTACLES INPARTITIONS. MC RUNS IN CEILING SPACE NOT TO EXCEED 3048MM (10'-0") IN LENGTH.

14.4. CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS:

208/120V PHASE 600/347V

RED A ORANGE

BLACK B BROWN

BLUE C YELLOW

WHITE NEUTRAL GRAY OR WHITE WITH TRACER

GREEN GROUND GREEN

WHITE WITH TRACER NEUTRAL FOR GFI CIRCUIT

14.5. CONDUCTORS #6AWG AND SMALLER SHALL HAVE COLOR CODED INSULATION. CONDUCTORS #4AWG AND LARGERSHALL BE IDENTIFIED WITH COLOR INSULATION OR PHASING TAPE.

14.6. CONDUCTOR SIZES SHALL BE INCREASED WHERE REQUIRED BY CODE AND/OR THE ENGINEER TO COMPENSATEFOR 2% VOLTAGE DROP AND HIGH AMBIENT TEMPERATURE.

14.7. COMMUNICATIONS CABLING RUN EXPOSED IN AIR HANDLING PLENUMS SHALL BE TYPE CMP PLENUM RATED.

14.8. SPLICES FOR WIRE SIZES #10 AWG AND SMALLER SHALL BE MADE WITH SPRING CONNECTORS AND TAPE.SPLICES FOR WIRE SIZES #8 AWG AND LARGER SHALL BE HYDRAULIC COMPRESSION TYPE WITH PRE-MOLDEDCOVER AND TAPE.

15. WIRING DEVICES

15.1. WIRING DEVICES SHALL BE SPECIFICATION-GRADE DECORA STYLE WITH NEMA CONFIGURATIONS AS INDICATED ONTHE DRAWINGS. COLOR OF DEVICES SHALL BE AS SELECTED BY THE ARCHITECT. WIRING DEVICES SHALL BEMANUFACTURED BY EATON, HUBBELL, LEVITON, LEGRAND OR APPROVED EQUAL.

15.2. PILOT LIGHT SWITCHES SHALL BE FURNISHED WITH LIGHTED HANDLE OR SEPARATE GLASS JEWEL INDICATINGLIGHT WIRED TO BE ILLUMINATED WHEN THE SWITCH IS ON.

15.3. FACEPLATES SHALL BE NON-MAGNETIC STAINLESS STEEL WITH BRUSHED FINISH UNLESS SPECIFIED BY THEARCHITECT. FACEPLATES SHALL BE FURNISHED FOR ALL OUTLETS AND SHALL BE CONFIGURED TO SUIT THESYSTEM SUPPLIERS' REQUIREMENTS.

15.4. DEVICES MOUNTED ADJACENT TO EACH OTHER SHALL BE FURNISHED WITH A COMMON FACEPLATE AND BEGANGED IN ONE BOX.

15.5. SWITCHES FEATURES: 20A, 120V, GENERAL PURPOSE AC TYPE, HIGHER RATINGS WHERE INDICATED, CSA LISTED,FULLY RATED FOR TUNGSTEN FILAMENT AND FLUORESCENT LAMPS, AND FOR INDUCTIVE LOADS, COMMERCIALGRADE, SILENT OPERATION, SUITABLE FOR BACK AND SIDE WIRING WITH TERMINALS RATED FOR NO. 10 AWGWIRE, SILVER ALLOY CONTACTS. PROVIDE SINGLE POLE, DOUBLE POLE, THREE-WAY, FOUR WAY SWITCHES ASINDICATED. COORDINATE COLOURS WITH ARCHITECT. STANDARD OF ACCEPTANCE ARE LUTRON, LEGRAND,ACUITY, HUBBEL, BRYANT ELECTRIC, COOPER-EATON, LEVITON.

15.6. WALL MOUNTED DIMMER SWITCHES SHALL BE DECORA-TYPE LUTRON OR LEGRAND WATT STOPPER, ANDSUITABLE FOR USE ON A 0-10V DIMMING CONTROL SYSTEM. COORDINATE SWITCH WITH LUMINAIRE DRIVER.MULTIPLE SWITCHES SHALL BE ALIGNED AND BUTTED TOGETHER WITH MULTI-GANG OUTLET BOX.

15.7. VACANCY SENSORS SHALL BE DUAL-TECHNOLOGY WITH PASSIVE INFRARED AND ULTRASONIC SENSINGMECHANISM. SENSOR TIMEOUT SHOULD BE PROGRAMMABLE BETWEEN 1 MINUTE AND 60 MINUTES. ALL VACANCYSENSORS SHALL BE PROVIDED WITH A MANUAL OVERRIDE SWITCH. LOCATION OF OVERRIDE SWITCH TO BECOORDINATED WITH CONSULTANT AND OWNER PRIOR TO INSTALLATION.

15.8. OCCUPANCY SENSORS SHALL BE LUTRON OR LEGRAND WATT STOPPER, DUAL-TECHNOLOGY WITH PASSIVEINFRARED AND ULTRASONIC SENSING MECHANISM. OCCUPANCY SENSORS SHALL BE CEILING-MOUNTED. SENSORTIMEOUT SHOULD BE PROGRAMMABLE BETWEEN 1 MINUTE AND 60 MINUTES. ALL OCCUPANCY SENSORS SHALL BEPROVIDED WITH A MANUAL OVERRIDE SWITCH. LOCATION OF OVERRIDE SWITCH TO BE COORDINATED WITHCONSULTANT AND OWNER PRIOR TO INSTALLATION.

15.9. COMBINATION DIMMING AND OCCUPANCY SWITCH IS TO BE WALL-MOUNTED IN DECORA-STYLE FACEPLATE IN ASINGLE-GANG ARRANGEMENT. OCCUPANCY SENSOR IS TO BE DUAL-TECHNOLOGY (PIR AND ULTRASONIC).DIMMING SWITCH IS TO BE SUITABLE FOR USE ON A 0-10V DIMMING CONTROL SYSTEM. MANUFACTURERSTANDARD OF ACCEPTANCE IS LEGRAND WATT STOPPER DW-311, OR APPROVED EQUIVALENT.

15.10. RECEPTACLES ARE TO BE DECORA STYLE, COLOUR TO BE COORDINATED WITH ARCHITECT. FEATURES: EIGHTBACK WIRED ENTRANCES, FOUR SIDE WIRING SCREWS, SUITABLE FOR NO. 10 AWG FOR BACK AND SIDE WIRING,BREAK-OFF LINKS FOR USE AS SPLIT RECEPTACLES, TRIPLE WIPE CONTACTS, RIVETED OR INTEGRAL GROUNDCONTACTS. MANUFACTURER STANDARD OF ACCEPTANCE IS PASS & SEYMOUR (LEGRAND), HUBBELL, BRYANTELECTRIC, COOPER-EATON, LEVITON.

15.11. GROUND FAULT CIRCUIT INTERRUPTERS (GFCI'S) FEATURES: CSA APPROVED TYPE A, COMPLETE WITH SUITABLEOUTLET BOX, 15A GROUNDED DUPLEX DECORA RECEPTACLE TYPE 5-15R, 15/20A GROUNDED DUPLEX DECORARECEPTACLE TYPE 5-20R WHERE INDICATED, SELF-TEST, MANUAL TEST, AND RESET SWITCH FEATURES, INCLUDECURRENT TRANSFORMER AND SENSING MECHANISM, UNIT TO TRIP AT 6MA, NO POWER AT DEVICE FACE IFREVERSE WIRED. COLOUR TO BE DETERMINED WITH ARCHITECT.

15.12. LABEL RECEPTACLES WITH CIRCUIT IDENTIFICATION USING A LAMACOID LABEL WITH COLOUR CODING FORNORMAL, EMERGENCY AND UPS SOURCE WITH LABEL ATTACHED TO RECEPTACLE.

15.13. CONTRACTOR SHALL UTILIZE THE FLOOR CELL WHEREVER POSSIBLE. PROVIDE SOURCE 1 FITTINGCONFIGURATION TO MATCH FLOOR PLAN. WHEN FLOOR CELL CANNOT BE UTILIZED CONTRACTOR SHALL PROVIDEAND INSTALL POKE-THRU FITTING WIREMOLD

15.14. CONTRACTOR SHALL PROVIDE AND INSTALL FLOOR BOXES, TO DELIVER POWER AND TELECOMMUNICATIONS/AVSERVICES AS INDICATED. COORDINATE TRENCHING AND/ OR CORING OF THE SLAB WITH STRUCTURAL ENGINEER,ARCHITECT, AND BUILDING MANAGEMENT. COORDINATE COVER FINISH WITH ARCHITECTS OR INTERIORDESIGNERS.

15.15. WALL MOUNTED DIGITAL PROGRAMMABLE TIMER SWITCH FOR AUTOMATIC CONTROL OF LIGHTING WITH MANUALOVERRIDE PROVISIONS SHALL BE BY PASS & SEYMOUR MODEL RT24 OR APPROVED EQUAL.

15.16. ALL DEVICES SHALL BE MOUNTED AT LOCATIONS AND HEIGHTS AS INDICATED ON ARCHITECTURAL DRAWINGS.

15.17. ALTER LOCATION OF OUTLETS/SWITCHES AT NO COST OR CREDIT, PROVIDING DISTANCE DOES NOT EXCEED 3M(10'-0") AND INFORMATION IS GIVEN BEFORE ROUGH-IN.

15.18. WHERE NEW, EXISTING OR NEW AND EXISTING SWITCHES ARE MOUNTED AT SAME LOCATION, MOUNT SWITCHESBEHIND COMMON FACEPLATE.

15.19. DOOR CHIME SHALL BE HARD-WIRED, 'NUTONE' MODEL LA14WH OR APPROVED EQUAL. PUSHBUTTON SHALL BEHARD-WIRED, 'NUTONE' MODEL PB67AB OR APPROVED EQUAL.

16. BRANCH CIRCUIT PANELBOARDS

16.1. BRANCH CIRCUIT PANELBOARDS SHALL BE 600/347V AND/OR 208/120V, 3Ø, 4-WIRE CONFIGURATION WITH COPPERBUS BARS, NEUTRAL BUS AND SEPARATE GROUND BUS BONDED TO PANEL ENCLOSURE. PROVIDE 200% NEUTRALAND ISOLATED GROUND BUS WHERE INDICATED ON DRAWINGS. CABLE LUGS SHALL BE MECHANICAL TYPE.PANELBOARDS SHALL BE MANUFACTURED BY SCHNEIDER ELECTRIC/SQUARE D, GENERAL ELECTRIC, SIEMENS, OREATON.

16.2. CIRCUIT BREAKERS SHALL BE MOLDED CASE, BOLT-IN-PLACE WITH THERMAL-MAGNETIC TRIP ELEMENT. MINIMUMINTERRUPTING RATINGS SHALL BE 22,000 AIC FOR 208/120V AND 65,000 AIC FOR 600/347V UNLESS NOTEDOTHERWISE ON DRAWINGS. CIRCUIT BREAKERS FOR UNSWITCHED LIGHTING CIRCUITS SHALL BE RATED FORSWITCHING DUTY. MAIN CIRCUIT BREAKERS SHALL BE MOUNTED SEPARATELY FROM BRANCH BREAKERS AT TOPOR BOTTOM. MOLDED CASE CIRCUIT BREAKERS TO BE AS PER CSA C22.2 NO.5.

16.3. PANELBOARD ENCLOSURES SHALL BE GALVANIZED CODE GAUGE STEEL WITHOUT PRE-PUNCHED KNOCKOUTS.TRIMS SHALL BE SURFACE TYPE IN UNFINISHED SPACES AND FLUSH TYPE IN FINISHED SPACES, WITH ANSI 61GRAY ENAMEL FINISH. DOORS SHALL BE DOOR IN DOOR TYPE CONSTRUCTION AND SHALL BE LOCKABLE AND ALLLOCKS SHALL BE KEYED ALIKE. FURNISH TWO KEYS FOR EACH PANEL.

16.4. PANELS SHALL HAVE A MINIMUM OF 4" GUTTER SPACE ON BOTH SIDES.

16.5. FURNISH AND INSTALL TYPEWRITTEN DIRECTORIES FOR EACH PANELBOARD, NEW AND EXISTING, INDICATINGDEVICES SERVED.

16.6. PANELS NOT MOUNTED ON STRUCTURAL WALLS SHALL BE SUPPORTED FROM THE FLOOR INDEPENDENTLY OFWALL CONSTRUCTION BUT LATERALLY SECURED TO WALL. FLUSH MOUNTED PANELBOARDS SHALL BE PROVIDEDWITH (3) 1" EMPTY CONDUITS TERMINATED ABOVE THE FINISHED CEILING.

16.7. PANELS MOUNTED ON MASONRY WALLS SHALL BE SHIMMED WITH WASHERS TO PROVIDE A 1/2" SPACE BETWEENPANELBOARD AND WALL.

17. LIGHTING FIXTURES AND EQUIPMENT

17.1. LIGHTING FIXTURES SHALL BE SPECIFICATION GRADE AND FURNISHED COMPLETE WITH ALL REQUIRED MOUNTINGHARDWARE. FIXTURES SPECIFIED IN THE LIGHTING FIXTURE SCHEDULE ESTABLISH THE PERFORMANCEREQUIREMENTS. SUBSTITUTIONS MUST MEET OR EXCEED THE PERFORMANCE OF THE SPECIFIED FIXTURE AND TOBE CSA APPROVED.

17.2. SUBMIT SCALED LAYOUT DRAWINGS FOR CONTINUOUS FIXTURES. SUBMIT SAMPLES WHEN REQUIRED BY THELIGHTING FIXTURE SCHEDULE OR WHEN REQUESTED FOR SUBSTITUTIONS.

17.3. LAMPS SHALL BE OF THE TYPES SPECIFIED IN THE LIGHTING FIXTURE SCHEDULE. ALL LAMPS OF ANY ONE TYPE

www.loringengineers.com

LORING CONSULTING ENGINEERS, INC.

TEL. (647) 352-9999TORONTO, ON M4V 2Y7

55 ST. CLAIR AVE. W, SUITE 201

NEW YORK, NY ● WASHINGTON, DC ● PRINCETON, NJ ● DURHAM, NC ● TORONTO, ON

Checked:

DRAWINGS ARE NOT TO BE SCALED.

CONSTRUCTION MUST CONFIRM TO ALL APPLICABLE CODESAND REQUIREMENTS OF THE AUTHORITIES HAVINGJURISDICTION.

CONTRACTOR MUST VERIFY AND ACCEPT RESPONSIBILITYFOR ALL DIMENSIONS AND CONDITIONS ON SITE AND SHALLNOTIFY THE APPROPRIATE CONSULTANT OF DISCREPANCIESWITH OR VARIATIONS FROM THE INFORMATION PROVIDEDBEFORE PROCEEDING WITH THE WORK.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTIONUNLESS SPECIFICALLY ISSUED "FOR CONSTRUCTION" OROTHERWISE CONFORMING TO THE DRAWINGS THAT FORM THEBASIS FOR WHICH A BUILDING PERMIT FOR THE PROJECT HASBEEN ISSUED.

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTSARE THE COPYRIGHT PROPERTY OF THE ARCHITECT ANDMUST BE RETURNED UPON REQUEST. REPRODUCTION OFDRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS INPART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECT'SWRITTEN PERMISSION.

N O T E S

11407

Entered:

Plot:

HIGHLAND HALLSHELL SPACE INTERIOR RETROFIT(UTSC PROJECT 2019-11)

UNIVERSITY OF TORONTO SCARBOROUGH1265 MILITARY TRAIL, TORONTO ON, M1C 1A4

ProjectNorth

2019-09-12Project No:

REF DATE DESCRIPTION

A 2019/09/13 ISSUED FOR 100%DD

B 2019/12/02 ISSUED FOR COORDINATION

C 2019/12/03 ISSUED FOR 99% REVIEW

D 2019/12/11 ISSUED FOR PERMIT

E 2020/02/03 ISSUED FOR TENDER

ELECTRICALSPECIFICATIONSSHEET 1

JFRAS

E-101

Page 3: E-601 PANEL SCHEDULES · ceiling mtd occupancy sensor c/w appropriate switch pack. 'a' - denotes switch designation ... electric heating coil electric unit heater fan coil unit combination

SHALL BE THE PRODUCT OF ONE MANUFACTURER. FURNISH 10% SPARE LAMPS OF EACH TYPE SPECIFIED.

17.4. CONTRACTOR SHALL ENSURE COMPATIBILITY BETWEEN FIXTURE TRIMS AND CEILING SYSTEMS. FIXTURESRECESSED IN ACCESSIBLE CEILINGS SHALL BE FURNISHED WITH SEISMIC RESTRAINTS. FIXTURES RECESSED INNON-ACCESSIBLE CEILINGS SHALL BE DESIGNED FOR BALLAST OR TRANSFORMER ACCESS THROUGH THEFIXTURE OPENING.

18. INSTALLATION OF OFFICE FURNITURE SYSTEM

18.1. THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY REGARDING ELECTRICAL POWER ANDCOMMUNICATIONS (DATA AND TELEPHONE) FOR COMPLETE FURNITURE SYSTEMS. THIS WORK SHALL INCLUDE, BUTNOT LIMITED TO THE FOLLOWING:

18.1.1.INSTALL ALL BASE SECTIONS ON TO THE MAIN FURNITURE PANEL WHERE POWER AND COMMUNICATIONS AREREQUIRED.

18.1.2.INSTALL ALL POWER AND COMMUNICATIONS WHIPS, CONNECTORS, RECEPTACLES, TASK LIGHT, ETC.

18.1.3.FURNISH AND INSTALL BRANCH CIRCUIT WIRING FROM ELECTRICAL PANELS VIA JUNCTION BOXES AT FLOOR,WALL, OR CEILING AS INDICATED ON DRAWINGS.

18.1.4.FURNISH AND INSTALL EMPTY CONDUIT WITH JUNCTION BOXES AND DRAG WIRES FOR TELEPHONE AND DATACABLES.

19. SPLICES AND TERMINATIONS

19.1. NO SPLICES OR JOINTS WILL BE PERMITTED IN EITHER FEEDER OR BRANCHES EXCEPT AT OUTLETS OR ACCESSIBLETERMINAL, SPLICE OR JUNCTION BOXES.

19.2. ALL MATERIALS REQUIRED FOR MAKING SPLICES AND/OR TERMINATIONS SHALL BE SUPPLIED IN COMPLETE KITSNOT OLDER THAN 6 MONTHS. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ENSURING THAT ALLMATERIALS FURNISHED WILL NOT ADVERSELY AFFECT THE PHYSICAL OR ELECTRICAL PROPERTIES OF OTHERMATERIALS FURNISHED OR OF THE WIRE OR CABLE ITSELF.

19.3. WHERE THE CONTRACTOR MAKES CONNECTIONS TO EXISTING WIRES, HE SHALL OPEN AND DISCONNECT THEEXISTING SPLICES FROM SUCH WIRES AND INSTALL NEW SPLICES TO INCLUDE THE EXISTING WIRES AS REQUIRED.

19.4. ALL SPLICES FOR WIRE SIZES #10 AWG AND SMALLER SHALL BE MADE WITH INSULATED SPRING CONNECTORAPPLIED TO TWISTED CONDUCTORS. TWO HALF LAPPED LAYERS OF VINYL TAPE EXTENDING A DISTANCE OF NOTLESS THAN ONE INCH FROM THE CONNECTOR SHALL BE APPLIED. SPLICES OTHER THAN THE AFOREMENTIONEDWILL BE PERMITTED AT THE DISCRETION OF THE ENGINEER.

19.5. ALL SPLICES FOR WIRE SIZES #8 AWG AND LARGER SHALL BE MADE WITH HYDRAULIC COMPRESSION TYPECONNECTORS WITH PRE-MOLDED COVER OVER WHICH TWO HALF LAPPED LAYERS OF VINYL TAPE EXTENDING ADISTANCE OF NOT LESS THAN ONE (1) INCH FROM THE CONNECTOR SHALL BE APPLIED.

20. IDENTIFICATION OF WORK

20.1. ALL PANELBOARDS, EQUIPMENT AND CABINETS SPECIFIED HEREIN SHALL BE CLEARLY IDENTIFIED WITH THEEQUIPMENT DESIGNATION, VOLTAGE AND AMPERE RATING, FUSE RATING, EQUIPMENT SERVED AND ORIGIN OF THEINCOMING FEED. IDENTIFICATION SHALL BE WHITE ON BLACK LAMACOID NAMEPLATE WITH 1/2" MINIMUM LETTERINGMECHANICALLY ATTACHED TO EQUIPMENT.

20.2. FACEPLATES OF SWITCHES FOR EQUIPMENT SUCH AS REMOTE FANS AND MOTORIZED SCREENS SHALL BEIDENTIFIED WITH THE NAME OF THE DEVICE CONTROLLED. IDENTIFICATION SHALL BE BY INDELIBLE MARKER INCONCEALED LOCATIONS AND ADHESIVE LABELS IN EXPOSED LOCATIONS. EMERGENCY DEVICES SHALL BEIDENTIFIED IN RED.

20.3. EMPTY CONDUITS SHALL BE IDENTIFIED WITH TAGS AT BOTH ENDS INDICATING THE LOCATION OF TERMINATIONAT THE OPPOSITE END.

20.4. BALLAST COMPARTMENTS FOR FIXTURES OPERATING AT GREATER THAN 120 VOLTS SHALL BE IDENTIFIED WITH ABRIGHT ORANGE ADHESIVE WARNING LABEL INDICATING VOLTAGE.

20.5. ALL WIRES SHALL BE IDENTIFIED BY PANEL AND CIRCUIT NUMBER AT ALL TERMINATION AND SPLICE POINTS BYTHE USE OF BRADY B-500 VINYL CLOTH TAPE OR EQUIVALENT METHOD.

20.6. ALL JUNCTION BOXES SHALL BE IDENTIFIED WITH PANEL AND CIRCUIT NUMBERS OF ALL CIRCUITS OR NAME OFCOMMUNICATIONS SYSTEM CABLING CONTAINED WITHIN. JUNCTION BOXES IN EXPOSED LOCATIONS SHALL BECLEARLY MARKED WITH IDENTIFYING LABELS. JUNCTION BOXES IN CONCEALED LOCATIONS SHALL BE MARKEDWITH A BOLD, INDELIBLE MARKING PEN. LETTERING SHALL BE NEATLY AND LEGIBLY PRINTED, JUNCTION BOXESON EMERGENCY SERVICE SHALL BE PAINTED RED AND LABELED AS EMERGENCY.

20.7. CONDUIT RUNS FOR BRANCH CIRCUITING AND/OR COMMUNICATIONS CABLING SHALL BE IDENTIFIED AT EVERY 50FEET OF LENGTH, AND AT EACH OUTLET AND PULL BOX WITH CIRCUIT NUMBER OR SYSTEM NAME.

21. INSTALLATION OF LIGHTING FIXTURES

21.1. LOCATIONS OF LIGHTING FIXTURES INDICATED ON THE DRAWINGS ARE APPROXIMATE. CONTRACTOR SHALL REFERTO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS, MODELS, AND TRIM TYPES OF ALL LIGHTINGFIXTURES PRIOR TO INSTALLATION.

21.2. RECESSED FIXTURES SHALL BE FURNISHED COMPLETE WITH MOUNTING DEVICES AND ACCESSORIES.

21.3. FIXTURES SHALL BE ATTACHED TO CEILING SUPPORTING MEMBERS, AND SHALL NOT DEPEND UPON LATHING ORPLASTER FOR ALIGNMENT OR SUPPORT. FIXTURES IN SUSPENDED CEILINGS SHALL BE SUPPORTED BY SADDLEHANGERS OR TIE-BARS ATTACHED TO RUNNERS OR BETWEEN CROSSBARS OF CEILING SYSTEMS. MOUNTINGSPLINES OR OTHER POSITIVE MEANS OF MAINTAINING ALIGNMENT AND RIGIDITY SHALL BE PROVIDED.SUPPORTING MEMBERS SHALL BE SURFACE PASSIVATED AND SHALL BE PRIMED OR PAINT DIPPED TO RESISTCORROSION. FASTENING DEVICES SHALL BE OF A POSITIVE, LOCKING TYPE, AND SHALL NOT REQUIRE THE USEOF SPECIAL TOOLS TO REMOVE. TIE WIRES SHALL NOT BE USED IN PLACE OF FASTENING DEVICES.

21.4. SPLICES SHALL NOT BE PERMITTED IN ANY RUN OF LIGHTING FIXTURE HOOKUP WIRE.

21.5. SEPARATELY MOUNTED OUTLET BOXES AND FLEXIBLE CONDUIT PIGTAIL CONNECTIONS (MAXIMUM LENGTH OF6'-0") SHALL BE PROVIDED FOR LIGHTING FIXTURES RECESSED IN HUNG CEILINGS WITH ACCESSIBLE TILES. ONE(1) OUTLET BOX MAY SERVE UP TO A MAXIMUM OF FOUR (4) RECESSED LIGHTING FIXTURES.

22. CUTTING AND PATCHING

22.1. ALL CUTTING AND PATCHING REQUIRED FOR EQUIPMENT INCLUDED IN THESE SPECIFICATIONS SHALL BE DONE BYTHIS CONTRACTOR.

22.2. CONTRACTOR SHALL NOT DO ANY CUTTING THAT MAY IMPAIR THE STRENGTH OF BUILDING CONSTRUCTION. NOHOLES ARE TO BE DRILLED INTO ANY STRUCTURAL MEMBERS. CLAMPS OR OTHER APPROVED HOLDING DEVICESARE TO BE USED.

22.3. ALL CUTTING OF EXISTING FLOORS, CEILINGS AND WALLS SHALL BE PERFORMED IN A MANNER SO AS TO MINIMIZEDAMAGE TO ADJACENT MATERIALS. PATCHING OF ALL SURFACES SHALL BE PERFORMED IN A MANNER APPROVEDBY THE ARCHITECT TO INSURE COMPLETE MATCHING WITH ADJACENT FINISHES AFTER FINAL TREATMENT OFSURFACES.

23. CORE DRILLING

23.1. CORED HOLES SHALL BE REVIEWED BY A STRUCTURAL ENGINEER PRIOR TO STARTING.

23.2. CORE DRILLING IS PERMITTED DURING OVERTIME HOURS ONLY. COORDINATE ALL DRILLING WITH BUILDINGMANAGEMENT PRIOR TO BEGINNING AND DRILLING.

23.3. FOR REMOVED OR ABANDONED OUTLETS, THE EXISTING CORED HOLE IN THE CONCRETE SLAB SHALL BE FILLEDWITH NON-SHRINK GROUT. THE FILLED HOLE SHALL BE ADJUSTED TO GRADE LEVEL.

23.4. BEFORE CORE DRILLING FLOOR SLAB OR STRUCTURAL WALLS, X-RAY SLAB OR WALLS AND HAVE THE LOCATIONSACCEPTED BY THE GENERAL CONTRACTOR IN WRITING.

23.5. CONTRACTOR SHALL USE A BAR LOCATOR TO DETERMINE IF REBARS INTERFERE WITH PROPOSED HOLE. IF THEREIS INTERFERENCE, THE CORE HOLE SHALL BE SHIFTED TO A NEW LOCATION ACCEPTABLE TO THE TENANT,STRUCTURAL ENGINEER AND ARCHITECT.

23.6. WHEN AN EXISTING HOLE IS TO BE REACTIVATED, INSPECT TO SEE IF REBARS HAVE BEEN CUT. IF REBARS HAVEBEEN CUT, INFORM THE GENERAL CONTRACTOR TO PROCEED TO REPAIR REBARS. PROCEED WITH A NEW COREHOLE AS DESCRIBED ABOVE.

24. SEALING OF PENETRATIONS

24.1. ALL PENETRATIONS OF WALLS, FLOORS OR CEILINGS MUST BE SEALED IN AN APPROVED MANNER USING AN OUTERCIRCUMFERENTIAL SLEEVE FILLED INSIDE AND OUT.

24.2. ALL PENETRATIONS OF FIRE RATED WALLS, FLOORS OR CEILINGS SHALL BE SEALED WITH FIRESTOPPINGMATERIAL LISTED WITH, AND BEAR LABEL OF CSA AND ULC, AND MAINTAIN SAME FIRE RATING AS FLOOR, WALL ORCEILING ASSEMBLY. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIRE RATED PARTITIONS.

25. HANGERS AND SUPPORTS

25.1. THREADED RODS SHALL BE FULLY GALVANIZED, MINIMUM 3/8" DIAMETER. MODULAR CHANNEL SUPPORTS SHALL BEGALVANIZED STEEL. SUPPORT CLIPS AND FASTENERS SHALL BE LISTED AND APPROVED FOR THE APPLICATION.STRAPS AND CLAMPS SHALL BE MALLEABLE IRON.

25.2. HANGERS MUST NOT BE WELDED TO STRUCTURAL STEEL MEMBERS AND BURNING OF HOLES IN STRUCTURALSTEEL IS PROHIBITED.

25.3. DO NOT USE ANY BASE BUILDING SUPPORTS OR EQUIPMENT, INCLUDING CEILING SUPPORT SYSTEM. SUPPORTFROM STRUCTURAL MEMBERS.

25.4. SUPPORTS SHALL BE SIZED TO ACCOMMODATE THE LOAD REQUIRED. ALL WORK SHALL BE SUPPORTEDINDEPENDENTLY OF THE WORK OF OTHER TRADES, INCLUDING CEILING SYSTEM SUPPORTS.

25.5. PANELS AND EQUIPMENT LOCATED ON OTHER THAN MASONRY WALLS SHALL BE MOUNTED WITH MODULARCHANNEL SUPPORTS SECURED TO THE BUILDING STRUCTURE.

25.6. APPROVED SEISMIC RESTRAINTS RATED TO RESIST 1/2G OF FORCE SHALL BE FURNISHED FOR ALL ELECTRICALWORK WHERE REQUIRED BY LOCAL BUILDING CODES AND THE AUTHORITIES HAVING JURISDICTION.

26. POWER INTERRUPTION NOTE

26.1. ELECTRICAL POWER MUST BE SHUT OFF PRIOR TO THE CONTRACTOR PERFORMING ANY WORK IN RACEWAYS WITHLIVE ELECTRICAL CIRCUITS OR ANY OTHER LIVE ELECTRICAL CIRCUITS OR EQUIPMENT. ANY POWER INTERRUPTIONSHALL BE COORDINATED WITH THE OWNER AND BUILDING OPERATING PERSONNEL, PROVIDING A MINIMUM OFSEVEN (7) DAYS ADVANCE NOTICE.

26.2. TAPS INTO LIVE RISERS ARE NOT PERMITTED.

27. FINAL CLEANUP AND FIELD TESTS

27.1. AFTER COMPLETION OF THE ENTIRE ELECTRICAL INSTALLATION:

27.1.1.THE CONTRACTOR, PRIOR TO FINAL ACCEPTANCE, SHALL CLEAN ALL PANELS, SWITCHES, CABINETS, DEVICESPLATES, FIXTURES AND OTHER ITEMS FURNISHED UNDER THIS CONTRACT AND SHALL ENSURE THAT ALLPANELBOARD DIRECTORIES ARE IN PLACE AND COMPLETED OR REVISED AS REQUIRED BY THE WORK, ANDTHAT ALL IDENTIFICATION AND MARKING OF EQUIPMENT, CABLES, ALL JUNCTION BOXES AND OTHER ITEMS ISCOMPLETED.

27.1.2.THE CONTRACTOR SHALL REPAIR OR REPLACE, AS DIRECTED BY THE ENGINEER, ANY ITEM DAMAGED DUE TOINSTALLATION OR RELOCATION OF EQUIPMENT OR DEVICES AT NO ADDITIONAL COST TO THE OWNER.

27.2. IN ADDITION TO OTHER TESTS WHICH MAY BE REQUIRED BY OTHER DIVISIONS, PERFORM FIELD TESTS IN THEPRESENCE OF THE ENGINEER, TO DEMONSTRATE THE PROPER FUNCTIONING OF THE ELECTRICAL INSTALLATION.THE ENGINEER SHALL BE GIVEN A MINIMUM OF 48 HOURS ADVANCE NOTICE OF ALL TESTS. REQUIRED FIELDTESTS SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING:

27.2.1.OPERATION OF ALL ELECTRICAL EQUIPMENT FOR A PERIOD FOR A PERIOD OF 24 HOURS WITHOUTINTERRUPTION.

27.2.2.1,000-VOLT MEGOHMMETER TEST FOR ALL WIRES AND CABLES FURNISHED. CONTRACTOR SHALL FURNISH ATEST REPORT TO THE ENGINEER INDICATING TEST METHOD USED AND RESULTS. IF GROUND RESISTANCE ONANY CIRCUIT IS LESS THAN THAT REQUIRED BY CSA, SUCH CIRCUITS ARE TO BE CONSIDERED DEFECTIVE ANDMUST BE REPLACED.

27.2.3.MEASURE PHASE CURRENT TO PANELBOARDS WITH NORMAL LOADS OPERATING AT TIME OF ACCEPTANCE.ADJUST BRANCH CIRCUIT CONNECTION AS REQUIRED TO OBTAIN THE BEST BALANCE OF CURRENT BETWEENPHASES AND SUBMIT A REPORT FOR INSERTION INTO MANUALS.

27.3. ALL DEFECTIVE FIXTURES CABLES OR OTHER EQUIPMENT ENCOUNTERED DURING THE COURSE OF TESTINGSHALL BE PROMPTLY REPLACED AND RETESTED TO THE SATISFACTION OF THE ENGINEER.

27.4. ELECTRIC WIRING TO CLASS "E" SYSTEMS FOR INSTALLATION AND RELOCATION OF FIRE ALARM DEVICES SHALL BEAPPROVED BY THE FIRE DEPARTMENT. CONTRACTOR MUST FILE FORM A-433 (APPLICATION FOR ELECTRICALINSPECTION) WITH THE FIRE DEPARTMENT. A WRITE-OFF MUST BE GIVEN TO THE BUILDING MANAGER AT THECOMPLETION OF JOB. SEE PAGE 31 OF RUDIN MANAGEMENTS PROCEDURES FOR ALTERATIONS INVOLVING CLASS"E" FIRE ALARM AND/OR COMMUNICATION SYSTEMS.

www.loringengineers.com

LORING CONSULTING ENGINEERS, INC.

TEL. (647) 352-9999TORONTO, ON M4V 2Y7

55 ST. CLAIR AVE. W, SUITE 201

NEW YORK, NY ● WASHINGTON, DC ● PRINCETON, NJ ● DURHAM, NC ● TORONTO, ON

Checked:

DRAWINGS ARE NOT TO BE SCALED.

CONSTRUCTION MUST CONFIRM TO ALL APPLICABLE CODESAND REQUIREMENTS OF THE AUTHORITIES HAVINGJURISDICTION.

CONTRACTOR MUST VERIFY AND ACCEPT RESPONSIBILITYFOR ALL DIMENSIONS AND CONDITIONS ON SITE AND SHALLNOTIFY THE APPROPRIATE CONSULTANT OF DISCREPANCIESWITH OR VARIATIONS FROM THE INFORMATION PROVIDEDBEFORE PROCEEDING WITH THE WORK.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTIONUNLESS SPECIFICALLY ISSUED "FOR CONSTRUCTION" OROTHERWISE CONFORMING TO THE DRAWINGS THAT FORM THEBASIS FOR WHICH A BUILDING PERMIT FOR THE PROJECT HASBEEN ISSUED.

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTSARE THE COPYRIGHT PROPERTY OF THE ARCHITECT ANDMUST BE RETURNED UPON REQUEST. REPRODUCTION OFDRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS INPART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECT'SWRITTEN PERMISSION.

N O T E S

11407

Entered:

Plot:

HIGHLAND HALLSHELL SPACE INTERIOR RETROFIT(UTSC PROJECT 2019-11)

UNIVERSITY OF TORONTO SCARBOROUGH1265 MILITARY TRAIL, TORONTO ON, M1C 1A4

ProjectNorth

2019-09-12Project No:

REF DATE DESCRIPTION

A 2019/09/13 ISSUED FOR 100%DD

B 2019/12/02 ISSUED FOR COORDINATION

C 2019/12/03 ISSUED FOR 99% REVIEW

D 2019/12/11 ISSUED FOR PERMIT

E 2020/02/03 ISSUED FOR TENDER

ELECTRICALSPECIFICATIONSSHEET 2

JFRAS

E-102

Page 4: E-601 PANEL SCHEDULES · ceiling mtd occupancy sensor c/w appropriate switch pack. 'a' - denotes switch designation ... electric heating coil electric unit heater fan coil unit combination

POWER AND SYSTEMS LEGEND:

PROJECT SPECIFIC NOTES:1 WAP'S TO BE INSTALLED ON UNDERSIDE OF CABLE TRAY. COORDINATE WITH UTSC IT FOR INSTILLATION.

CONNECT NEW 4"X18" CABLE TRAY TO EXISTING 4"X18" CABLE TRAY. REFER TO DRAWING NOTE 3.

RELOCATE EXISTING SECURITY DOOR CONTROLLER TO OTHER SIDE OF EXISTING 4"X4" JUNCTION BOX "SEC". DISCONNECT, EXTEND AND RETERMINATECARD ACCESS WIRING TO SUIT NEW LOCATION.

PROVIDE ITEMIZED PRICE FOR: SUPPLY AND INSTALL OF DOOR OPERATOR, ELECTRIC STRIKE, AND PUSH BUTTONS AS SHOWN.

GENERAL NOTES THAT APPLY TO ALL DRAWINGS ON THIS SHEET:

1. THIS DRAWING'S "EXISTING" PART IS ISSUED FOR REFERENCE PURPOSES, IT REPRESENTS AN INVENTORY OF THE MAIN EXISTING INSTALLATIONS, GENERALLYVERIFIED IN CONNECTION WITH THE MODIFICATIONS SHOWN ON THIS DRAWING'S "MODIFIED" PART, AND OF WHICH THE GENUINE CONDITIONS MUST BEOBSERVED ON THE SITE BY THE CONTRACTOR.

2. REFER TO APPENDIX A FOR UTSC ELECTRICAL AND I.T. SPECFICATIONS.

3. SECURITY HARDWARE AND DEVICES ARE TO BE SUPPLIED BY THE OWNER'S SECURITY VENDOR (HONEYWELL). ELECTRICAL CONTRACTOR TO PROVIDE 1"CONDUIT FROM ALL DOOR LOCATIONS REQUIRING ACCESS CONTROL DEVICES TO NEAREST IT RACK FOR CONNECTION TO PCSC FAULT TOLERANT NETWORKCONTROLLERS (EXISTING). ALL WIRING FOR SECURITY DEVICES IS TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR IN COORDINATION WITH THE SECURITYVENDOR REQUIREMENTS.

4. PROVIDE 3/4"CONDUIT TERMINATING TO NEAREST IT RACK FOR ALL DATA OUTLETS. REFER TO UTSC I.T. SPECIFICATIONS IN APPENDIX A FOR STANDARDS ONCABLING, COLOUR, LABEL, NAMING, ETC.

HATCH INDICATES AREAS NOT IN SCOPE

2

3

4

UP

UP

UP

-3750

Fre

B125

STUDENTCOMMONSLEVEL 00

B127

TENANTFIT-UP

B126

CARETAKINGSTORAGE

B129

MECHPUMPROOM

B124CSTORAGE

B172SSTAIR D

B173SSTAIR E

B124KCORRIDOR

B129ACOMMUNICATIONS

B112W

B124A

SPRINKLERROOM

281S-ASTAIR H-LL

B124BCOMM

FINANCIAL SERVICESSTORAGE

CORRIDOR

F B F BF B

F BF B

F B

F B

F B

F B

F BF B F B

F BF B

F B

F B

F B

F B

F BF B

F B

F B

F B F B

F B

F B

F B

F BF B

F B

F B

F B

F B

F B

F B

F B

F B

F BF B

F B

F BF B

F B

F B F B

F B

F B

F B

F BF B

F BF BF B

F B F BF B

F B

F B

F B

F B

F B

F B

F B

F B

F B

F B

F B

F B

F B

F B

F B

F B

F BF B

F B

F B

F B

F B

FB FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB FB

FB FB

FB FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FBFB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB FB FB

FB

FB

FB

FB

FB

FBFB FB

FB

FB

FB FB

FB

FBFB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FBFB

FBFB

FB

FB FB

FB FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FBFB

FB

FB

FB

FB

FB

FB

FB

FBFB

FBFB

FB

FB

FB

FB

FB

FBFB

FB

FB

FB

FB

FB

FB

FB

FB

FB FB

FB

FB

FBFB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB FB

FBFB

FB

FB

FBFB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB FB

FB

FB FB

FB

FBFB

FB FB

FB

FB FB

FB

FB

FB

FB

FB

FBFBFB

FBFBFB

FB

FB

FB

FBFB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB FBFB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB FB

FB

FB

FB

FB

FB

FB

FB

FB

FBFB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB FB

FB

FB

FB

FB

FB

FB

FB FB

FB

FB

FB

FB

FB

FB

FB

FBFB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

B124E

LIBRARYSTORAGE

B124D

PB PB

B124K

B124FPANEL`RP-BA-4RA'

CR

CR

5E-311

ES

ES

PANEL`MP-BA-1MA'

RP-BA-4RA-3

EX

EX

EX

EX

EX

EX

EX

RP-B

A-4R

A-5

RP-BA-4RA-3

RP-B

A-4R

A-5

RP-B

A-4R

A-5

RP-BA-4RA-5

RP-BA-4RA-3

RP-BA-4RA-5

MP-BA-1MA-15MP-BA-1MA-15

MP-BA-1MA-15

MP-BA-1MA-15

MP-BA-1MA-17

MP-BA-1MA-17

MP-BA-1MA-17

MP-BA-1MA-17

RP-B

A-4R

A-7(

SC)

DOOR OPERATOR `DO-1'RP-BA-4RA-9

EX

2D 2D

2D

2D1

1

11

RP-BA-4RA-32" X 12" CABLE TRAY

2" X 12" CABLE TRAY

ES4

DOOR OPERATOR 'DO-2'RP-BA-4RA-9

VAV-N6

VAV-N7

VAV-N5VAV-105

VAV-N1

VAV-N2

VAV-107

VAV-N4 2

4" X 18" CABLE TRAY

E

J3

230

ELECTRICALROOM

EMERGENCY LIGHTINGPANEL `ELP-BA-1A'

EMERGENCY LIGHTINGPANEL `LP-BA-1A'

EX

EX

16

17a

18a

19a

17

18

19

LJ7J6J4J3J2J1 J5

exCO

exCO

exCO ex

CO

DN

UP

UP

UP

UP

UP

DN

UP

UP

UP

UP

F ex

F exex

F ex

Fre

F ex

ex

ex

ex

ex

T

PS

PB PB

4E-311

PROJECT AREA5

E-311

17

H1

B129ACOMMUNICATIONS

EXISTINGIT RACK

www.loringengineers.com

LORING CONSULTING ENGINEERS, INC.

TEL. (647) 352-9999TORONTO, ON M4V 2Y7

55 ST. CLAIR AVE. W, SUITE 201

NEW YORK, NY ● WASHINGTON, DC ● PRINCETON, NJ ● DURHAM, NC ● TORONTO, ON

Checked:

DRAWINGS ARE NOT TO BE SCALED.

CONSTRUCTION MUST CONFIRM TO ALL APPLICABLE CODESAND REQUIREMENTS OF THE AUTHORITIES HAVINGJURISDICTION.

CONTRACTOR MUST VERIFY AND ACCEPT RESPONSIBILITYFOR ALL DIMENSIONS AND CONDITIONS ON SITE AND SHALLNOTIFY THE APPROPRIATE CONSULTANT OF DISCREPANCIESWITH OR VARIATIONS FROM THE INFORMATION PROVIDEDBEFORE PROCEEDING WITH THE WORK.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTIONUNLESS SPECIFICALLY ISSUED "FOR CONSTRUCTION" OROTHERWISE CONFORMING TO THE DRAWINGS THAT FORM THEBASIS FOR WHICH A BUILDING PERMIT FOR THE PROJECT HASBEEN ISSUED.

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTSARE THE COPYRIGHT PROPERTY OF THE ARCHITECT ANDMUST BE RETURNED UPON REQUEST. REPRODUCTION OFDRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS INPART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECT'SWRITTEN PERMISSION.

N O T E S

11407

Entered:

Plot:

HIGHLAND HALLSHELL SPACE INTERIOR RETROFIT(UTSC PROJECT 2019-11)

UNIVERSITY OF TORONTO SCARBOROUGH1265 MILITARY TRAIL, TORONTO ON, M1C 1A4

ProjectNorth

2019-09-12Project No:

REF DATE DESCRIPTION

A 2019/09/13 ISSUED FOR 100%DD

B 2019/12/02 ISSUED FOR COORDINATION

C 2019/12/03 ISSUED FOR 99% REVIEW

D 2019/12/11 ISSUED FOR PERMIT

E 2020/02/03 ISSUED FOR TENDER

1E-311

GROUND FLOOR - PLAN1:100

4E-311

PART PLAN - ELECTRICAL ROOM1:75

0 5 10 20 50 METERS

POWER AND SYSTEMSNEW WORK PLAN

JFRAS

E-311

5E-311

PART PLAN - IT ROOM1:50

6E-311

KEY PLAN1:400

SECURITY JUNCTION BOX ON SECURE SIDE OF DOOR(BY ELECTRICAL)

PROXIMITY CARD READER

DOUBLE GANG BACK BOX W/ SINGLE GANG TRIM PLATE(BY ELECTRICAL)

RECESSED DOOR POSITION SWITCH (DOOR CONTACT)

ELECTRIC STRIKE

REQUEST TO EXIT MOTION DETECTOR

AUTO DOOR OPERATOR EQUIPMENT(BY DOOR HARDWARE)

DUST BOX /MORTAR SHIELD IN FRAME AS REQUIRED(BY DOOR HARDWARE)

AUTOMATIC DOOR OPERATOR PUSHBUTTON(BY DOOR HARDWARE)

1

2

2A

3

4

5

6

7

8

DOOR LEGEND & MATERIALS

SECURE SIDEPUBLIC SIDEFINISHED FLOOR

TO SECURITY PANELSLAB CEILING

DOOR OPERATOR POWER SUPPLY(BY ELECTRICAL)

1 1

3 6

4

7 5FINISHED CEILING (AS APPLICABLE)

8 8

2A

2

40" (

1000

mm)

3/4"C (21mmC)

2E-311

SINGLE DOOR W/ READER IN, BARRIER FREE, ELECTRIC STRIKEN.T.S.

3E-311

SINGLE DOOR W/ READER IN, ELECTRIC STRIKEN.T.S.

LINE TYPES LEGEND

CABLE INSIDE DOOR FRAMES/DOORS

CONDUIT INSTALLED IN WALL SPACE

CONDUIT INSTALLED IN CEILING SPACE

PUBLIC SIDE SECURE SIDEFINISHED FLOOR

SLAB CEILINGTO SECURITY PANEL

1 1

5

3

4

FINISHED CEILING (AS APPLICABLE)

2A

2

7

1"C (27mmC)

3/4"C (21mmC)

40" (

1000

mm)

SECURITY JUNCTION BOX ON SECURE SIDE OF DOOR(BY ELECTRICAL)

PROXIMITY CARD READER

DOUBLE GANG BACK BOX W/ SINGLE GANG TRIM PLATE(BY ELECTRICAL)

RECESSED DOOR POSITION SWITCH

ELECTRIC STRIKE

REQUEST TO EXIT MOTION DETECTOR

AUTO DOOR OPERATOR EQUIPMENT(BY DOOR HARDWARE)

DUST BOX /MORTAR SHIELD IN FRAME AS REQUIRED(BY DOOR HARDWARE)

AUTOMATIC DOOR OPERATOR PUSHBUTTON(BY DOOR HARDWARE)

1

2

2A

3

4

5

6

7

8

DOOR LEGEND & MATERIALS

NOTES:1. UNLESS OTHERWISE NOTED HEREIN OR WITHIN THE PROJECT

SPECIFICATION, ALL CONDUIT AND BOXES ARE TO BE PROVIDED BYELECTRICAL CONTRACTOR, ALL HARDWARE IS PROVIDED BY SECURITYCONTRACTOR. COMMISSIONING OF SYSTEM IS BY SECURITY VENDORIN COORDINATION WITH OTHER TRADES AND THE PROJECT OWNER.

2. PROVIDE EACH SECURITY DEVICE WITH ONE (1) DATA DROP TO BETERMINATED IN COMMUNICATIONS ROOM. COORDINATE INSTALLATIONWITH SECURITY VENDOR.

1"C (27mmC)

LINE TYPES LEGEND

CABLE INSIDE DOOR FRAMES/DOORS

CONDUIT INSTALLED IN WALL SPACE

CONDUIT INSTALLED IN CEILING SPACE

NOTES:1. UNLESS OTHERWISE NOTED HEREIN OR WITHIN THE PROJECT

SPECIFICATION, ALL CONDUIT AND BOXES ARE TO BE PROVIDED BYELECTRICAL CONTRACTOR, ALL HARDWARE IS PROVIDED BY SECURITYCONTRACTOR. COMMISSIONING OF SYSTEM IS BY SECURITY VENDORIN COORDINATION WITH OTHER TRADES AND THE PROJECT OWNER.

2. PROVIDE EACH SECURITY DEVICE WITH ONE (1) DATA DROP TO BETERMINATED IN COMMUNICATIONS ROOM. COORDINATE INSTALLATIONWITH SECURITY VENDOR.

P1E-311

EXISTING COMMUNICATIONS ROOM (B124B)N.T.S.

P1E-311

3

REMOVE AND REINSTALLSECURITY DOOR CONTROLLER TORIGHT SIDE OF 'SEC' JUNCTIONBOX TO CLEAR SPACE FOREXTENSION OF CABLE TRAY.

Page 5: E-601 PANEL SCHEDULES · ceiling mtd occupancy sensor c/w appropriate switch pack. 'a' - denotes switch designation ... electric heating coil electric unit heater fan coil unit combination

UP

UP

UP

UP

16

17a

18a

19a

LJ7J6J5J4J3J2J1H1G1

17

18

19

15

B125

STUDENTCOMMONSLEVEL 00

B127

TENANTFIT-UP

B126

CARETAKINGSTORAGE

B129

MECHPUMPROOM

B124CSTORAGE

B172SSTAIR D

B173SSTAIR E

B124KCORRIDOR

B129ACOMMUNICATIONS B124A

SPRINKLERROOM

281S-ASTAIR H-LL

B124BCOMM

B124SHELL SPACE

EX

EX EX EX

EX

ER EX EX

ER EX EX

ER EX EX

ER

EX

EX

EX

EX

MEX

MER

EXM

EX

M

OSEX

OS EX

OSEX

OS EX

S

EX

LC ER

LC EX

LC EX

EX S EX S S EX S EX

SEX S EX S SEX S EX

SEX

S EX S S EX S EX

SEX

SEX

S SEX

SEX

S EX

S EX

SEX

ER

ER

ER

ER

LC ER

ER

F EX

F EX

FEX

FEX

F EX

F

F

F EX

LC ER

LIGHTING LEGEND:

GENERAL NOTES THAT APPLY TO ALL DRAWINGS ON THIS SHEET:

1. THIS DRAWING'S "EXISTING" PART IS ISSUED FOR REFERENCE PURPOSES, IT REPRESENTS AN INVENTORY OF THE MAIN EXISTING INSTALLATIONS,GENERALLY VERIFIED IN CONNECTION WITH THE MODIFICATIONS SHOWN ON THIS DRAWING'S "MODIFIED" PART, AND OF WHICH THE GENUINE CONDITIONSMUST BE OBSERVED ON THE SITE BY THE CONTRACTOR.

2. CONTRACTOR TO PUT ASIDE REMOVED DEVICES AND TURN OVER TO OWNER FOR RE-USE FOLLOWING DEMOLITION.

HATCH INDICATES AREAS NOT IN SCOPE

www.loringengineers.com

LORING CONSULTING ENGINEERS, INC.

TEL. (647) 352-9999TORONTO, ON M4V 2Y7

55 ST. CLAIR AVE. W, SUITE 201

NEW YORK, NY ● WASHINGTON, DC ● PRINCETON, NJ ● DURHAM, NC ● TORONTO, ON

Checked:

DRAWINGS ARE NOT TO BE SCALED.

CONSTRUCTION MUST CONFIRM TO ALL APPLICABLE CODESAND REQUIREMENTS OF THE AUTHORITIES HAVINGJURISDICTION.

CONTRACTOR MUST VERIFY AND ACCEPT RESPONSIBILITYFOR ALL DIMENSIONS AND CONDITIONS ON SITE AND SHALLNOTIFY THE APPROPRIATE CONSULTANT OF DISCREPANCIESWITH OR VARIATIONS FROM THE INFORMATION PROVIDEDBEFORE PROCEEDING WITH THE WORK.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTIONUNLESS SPECIFICALLY ISSUED "FOR CONSTRUCTION" OROTHERWISE CONFORMING TO THE DRAWINGS THAT FORM THEBASIS FOR WHICH A BUILDING PERMIT FOR THE PROJECT HASBEEN ISSUED.

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTSARE THE COPYRIGHT PROPERTY OF THE ARCHITECT ANDMUST BE RETURNED UPON REQUEST. REPRODUCTION OFDRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS INPART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECT'SWRITTEN PERMISSION.

N O T E S

11407

Entered:

Plot:

HIGHLAND HALLSHELL SPACE INTERIOR RETROFIT(UTSC PROJECT 2019-11)

UNIVERSITY OF TORONTO SCARBOROUGH1265 MILITARY TRAIL, TORONTO ON, M1C 1A4

ProjectNorth

2019-09-12Project No:

REF DATE DESCRIPTION

A 2019/09/13 ISSUED FOR 100%DD

B 2019/12/02 ISSUED FOR COORDINATION

C 2019/12/03 ISSUED FOR 99% REVIEW

D 2019/12/11 ISSUED FOR PERMIT

E 2020/02/03 ISSUED FOR TENDER

1E-401

GROUND FLOOR - PLAN1:100

0 5 10 20 50 METERS

LIGHTINGDEMOLITION PLAN

JFRAS

E-401

Page 6: E-601 PANEL SCHEDULES · ceiling mtd occupancy sensor c/w appropriate switch pack. 'a' - denotes switch designation ... electric heating coil electric unit heater fan coil unit combination

1

DRAWING NOTES:

REVISE LOCAL LIGHTING CONTROLS FOR EXISTING-TO-REMAIN LIGHTING IN AREA INDICATED. SWITCHES AND OCCUPANCY SENSORS TO CONTROL LOCALZONE LIGHTING ONLY.

POWER AND SYSTEMS LEGEND:

GENERAL NOTES THAT APPLY TO ALL DRAWINGS ON THIS SHEET:

1. THIS DRAWING'S "EXISTING" PART IS ISSUED FOR REFERENCE PURPOSES, IT REPRESENTS AN INVENTORY OF THE MAIN EXISTING INSTALLATIONS,GENERALLY VERIFIED IN CONNECTION WITH THE MODIFICATIONS SHOWN ON THIS DRAWING'S "MODIFIED" PART, AND OF WHICH THE GENUINE CONDITIONSMUST BE OBSERVED ON THE SITE BY THE CONTRACTOR.

2. CONTRACTOR TO ALLOW FOR REMOVAL AND REINSTALLATION OF ALL FIRE ALARM SPEAKERS WITHIN THE PROJECT AREA IN COORDINATION WITH OTHERTRADES, AS REQUIRED. CONTRACTOR RESPONSIBLE FOR RE-VERIFYING ALL FIRE ALARM EQUIPMENT IMPACTED BY THE WORK.

3. ALL LIGHTING CONTROLS ARE TO BE COMPATIBLE WITH EXISTING LUTRON LIGHTING CONTROL SYSTEM CONTROL SYSTEM. INCLUDE FOR COMMISSIONINGAND PROGRAMMING OF LIGHTING CONTROL SYSTEM.

4. ALL FIRE ALARM DEVICES TO BE COMPATIBLE WITH EXISTING SIEMENS FIRE ALARM SYSTEM. COORDINATE WITH BASE BUILDING FIRE ALARM VENDOR(SIEMENS).

5. NEW EMERGENCY LIGHTING IS TO BE TIED INTO EXISTING CIRCUIT WIRING IDENTIFIED AND LOCATED WITHIN THE PROJECT AREA. CONFIRM CIRCUITLOADING DOES NOT EXCEED 80% OF BREAKER RATING. ALLOW FOR INSTALLATION TO ALTERNATE EXISTING 20A.1P SPARE BREAKER FOR EXISTINGLIGHTING CIRCUITS. REFER TO DRAWING E-311 FOR EMERGENCY LIGHTING PANEL LOCATION.

5. NEW LIGHTING IS TO BE TIED INTO EXISTING CIRCUIT WIRING IDENTIFIED AND LOCATED WITHIN THE PROJECT AREA. CONFIRM CIRCUIT LOADING DOES NOTEXCEED 80% OF BREAKER RATING. ALLOW FOR INSTALLATION TO ALTERNATE EXISTING 20A.1P SPARE BREAKER FOR EXISTING LIGHTING CIRCUITS. REFERTO DRAWING E-311 FOR LIGHTING PANEL LOCATION.

6. ALL EXISTING EMERGENCY LIGHTING SHOWN IS TO REMAIN, UNLESS OTHERWISE NOTED.

7. COORDINATE LIGHTING FIXTURE INSTALLATION WITH MECHANICAL EQUIPMENT INCLUDING DUCTWORK.

8. NEW EXIT SIGNS TO MATCH EXISTING WITHIN SPACE.

HATCH INDICATES AREAS NOT IN SCOPE

UP

UP

UP

UP

16

17a

18a

19a

LJ7J6J4J3J2J1H1G1

17

18

19

15

CL

CL CL

CL

CLCLCL

CL

CLCL

CL CL

Fre

B125

STUDENTCOMMONSLEVEL 00

B127

TENANTFIT-UP

B126

CARETAKINGSTORAGE

B129

MECHPUMPROOM

B124CSTORAGE

B172SSTAIR D

B173SSTAIR E

B124KCORRIDOR

B129ACOMMUNICATIONS

B112W

B124A

SPRINKLERROOM

281S-ASTAIR H-LL

B124BCOMM

J5

FINANCIAL SERVICESSTORAGE

CORRIDOR

PS

B124E

LIBRARYSTORAGE

B124D

PB PB

B124K

B124F

LC RL

LC RL

F F OSOS

OS OS

OS

F F

RL

RL

RL

RL

EX

EX EX EX

EX

EX EX

EX EX

EX EX

EX

EX

EX

EX

MEX

EXM

EX

M

OSEX

OS EX

OSEX

OS EX

S

EX

LC EX

LC EX

EX S EX S EX S EX

SEX S EX SEX S EX

SEX

S EX S EX S EX

SEX

SEX

SEX

SEX

S EX

S EX

SEX

F EX

F EX

FEX

FEX

F EX

F EX

RL

RL

RL

RL

MRL

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1

A1

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

A1ELP-BA-1A-2

OS

A1

A1

a

LIGHTING CONTROL ZONE `a'

b b

LIGHTING CONTROL ZONE `b'

LIGHTING CONTROL ZONE `c'

1

1

LP-BA-1A-2

LP-BA-1A-4

LP-BA-1A-4

LIGHTING CONTROL ZONE `d'

LP-BA-1A-4

c c

d

A1ELP-BA-1A-2

LC

A1 A1A1 A1 A1 A1 A1 A1 A1 A1

A1A1

A1 A1 A1 A1 A1 A1 A1 A1 A1

A1 A1 A1 A1 A1 A1 A1 A1 A1 A1

A1 A1 A1

A1 A1 A1 A1 A1 A1 A1 A1 A1

A1 A1 A1 A1 A1 A1 A1 A1 A1 A1

www.loringengineers.com

LORING CONSULTING ENGINEERS, INC.

TEL. (647) 352-9999TORONTO, ON M4V 2Y7

55 ST. CLAIR AVE. W, SUITE 201

NEW YORK, NY ● WASHINGTON, DC ● PRINCETON, NJ ● DURHAM, NC ● TORONTO, ON

Checked:

DRAWINGS ARE NOT TO BE SCALED.

CONSTRUCTION MUST CONFIRM TO ALL APPLICABLE CODESAND REQUIREMENTS OF THE AUTHORITIES HAVINGJURISDICTION.

CONTRACTOR MUST VERIFY AND ACCEPT RESPONSIBILITYFOR ALL DIMENSIONS AND CONDITIONS ON SITE AND SHALLNOTIFY THE APPROPRIATE CONSULTANT OF DISCREPANCIESWITH OR VARIATIONS FROM THE INFORMATION PROVIDEDBEFORE PROCEEDING WITH THE WORK.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTIONUNLESS SPECIFICALLY ISSUED "FOR CONSTRUCTION" OROTHERWISE CONFORMING TO THE DRAWINGS THAT FORM THEBASIS FOR WHICH A BUILDING PERMIT FOR THE PROJECT HASBEEN ISSUED.

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTSARE THE COPYRIGHT PROPERTY OF THE ARCHITECT ANDMUST BE RETURNED UPON REQUEST. REPRODUCTION OFDRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS INPART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECT'SWRITTEN PERMISSION.

N O T E S

11407

Entered:

Plot:

HIGHLAND HALLSHELL SPACE INTERIOR RETROFIT(UTSC PROJECT 2019-11)

UNIVERSITY OF TORONTO SCARBOROUGH1265 MILITARY TRAIL, TORONTO ON, M1C 1A4

ProjectNorth

2019-09-12Project No:

REF DATE DESCRIPTION

A 2019/09/13 ISSUED FOR 100%DD

B 2019/12/02 ISSUED FOR COORDINATION

C 2019/12/03 ISSUED FOR 99% REVIEW

D 2019/12/11 ISSUED FOR PERMIT

E 2020/02/03 ISSUED FOR TENDER

1E-411

GROUND FLOOR - PLAN1:100

0 5 10 20 50 METERS

LIGHTINGNEW WORK PLAN

JFRAS

E-411

LUMINAIRE SCHEDULE

TYPE DESCRIPTION MANUFACTURER/SERIES MODEL LAMP

FITURE INPUTTRIM REMARKSVOLT

(V)LOAD

(W)

A1

4' SUSPENDED LINEARDIRECT/INDIRECT LED LIGHT FIXTURE

C/W 3500K, 90CRI, 500 LUMEN/FT DIRECTOUTPUT, 500 LUMEN/FT INDIRECTOUPUT, 0-10V DIMMING DRIVER,

AIRCRAFT CABLING MOUNTING AND120V INPUT.

LUMENWERX/VIA3

VIA3PDI-HLO-FH-WIO-LED-90-500-500-35-X-UNV-D1-1-53WAC36-X LED 120-277 39.5 -

CONFIRM SUSPENSION HEIGHT, FINISH, ANDCANOPY FINISH WITH ARCHITECT. REFER TO

LIGHTING LAYOUT FOR TOTAL CONTINUOUS RUNLENGTHS.

LIGHT FIXTURES FED FROM AN EMERGENCYPOWER SOURCE SHALL OVERRIDE ALL LIGHTINGCONTROL AND GO TO FULL BRIGHTNESS, UPON

LOSS OF POWER.

ALTERNATE STANDARD OF ACCEPTANCE:PEERLESS SQUARE LED

Page 7: E-601 PANEL SCHEDULES · ceiling mtd occupancy sensor c/w appropriate switch pack. 'a' - denotes switch designation ... electric heating coil electric unit heater fan coil unit combination

www.loringengineers.com

LORING CONSULTING ENGINEERS, INC.

TEL. (647) 352-9999TORONTO, ON M4V 2Y7

55 ST. CLAIR AVE. W, SUITE 201

NEW YORK, NY ● WASHINGTON, DC ● PRINCETON, NJ ● DURHAM, NC ● TORONTO, ON

Checked:

DRAWINGS ARE NOT TO BE SCALED.

CONSTRUCTION MUST CONFIRM TO ALL APPLICABLE CODESAND REQUIREMENTS OF THE AUTHORITIES HAVINGJURISDICTION.

CONTRACTOR MUST VERIFY AND ACCEPT RESPONSIBILITYFOR ALL DIMENSIONS AND CONDITIONS ON SITE AND SHALLNOTIFY THE APPROPRIATE CONSULTANT OF DISCREPANCIESWITH OR VARIATIONS FROM THE INFORMATION PROVIDEDBEFORE PROCEEDING WITH THE WORK.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTIONUNLESS SPECIFICALLY ISSUED "FOR CONSTRUCTION" OROTHERWISE CONFORMING TO THE DRAWINGS THAT FORM THEBASIS FOR WHICH A BUILDING PERMIT FOR THE PROJECT HASBEEN ISSUED.

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTSARE THE COPYRIGHT PROPERTY OF THE ARCHITECT ANDMUST BE RETURNED UPON REQUEST. REPRODUCTION OFDRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS INPART OR IN WHOLE IS FORBIDDEN WITHOUT THE ARCHITECT'SWRITTEN PERMISSION.

N O T E S

11407

Entered:

Plot:

HIGHLAND HALLSHELL SPACE INTERIOR RETROFIT(UTSC PROJECT 2019-11)

UNIVERSITY OF TORONTO SCARBOROUGH1265 MILITARY TRAIL, TORONTO ON, M1C 1A4

ProjectNorth

2019-09-12Project No:

REF DATE DESCRIPTION

A 2019/09/13 ISSUED FOR 100%DD

B 2019/12/02 ISSUED FOR COORDINATION

C 2019/12/03 ISSUED FOR 99% REVIEW

D 2019/12/11 ISSUED FOR PERMIT

E 2020/02/03 ISSUED FOR TENDER

PANEL SCHEDULES

ABCA

E-601