Citation preview
E-115 EP33,000 kW / 4,000 kW
www.enercon.de
6,000
8,000
9,000
7,000
10,000
12,000
13,000
14,000
15,000
16,000
17,000
18,000
19,000
11,000
20,000
MWh per year
Average wind speed at hub height (m/s)
6.7 6.9 7.1 7.3 7.5 7.7 7.9 8.1 8.3 8.5 8.7 8.9 9.1 9.3 9.5 9.7 9.9 10
E-115 EP3 / 4,000 kW
TECHNICAL DATA
E-115 EP3
The new EP3 range represents a radical cut in ENERCON’s wind energy converter design. Compact and efficient with consistently optimised processes from production, transport and logistics to installation – these are the key characteristics of this WEC generation and ENERCON’s response to new market requirements.
* dependent on hub height
GENERAL Nominal power 3,000 kW / 4,000 kWWind class (IEC) IEC IA IEC IIAWind zone (DIBt) - Turbine concept gearless, variable speed, full power converterDesign service life 25 yearsCut in wind speed 2.5 m/sCut out wind speed 34 m/sExtreme wind speedat hub height (3-second gust) 59.5 m/s (IEC IIA) 70 m/s (IEC IA)Rotational speed 4.4 - 12.8 rpm (3,000 kW) 4.4 - 13.2 rpm (4,000 kW) Ambient temperaturefor normal operation -10 °C to +40 °CExtreme temperature range -20 °C to +50 °CGrid feed /control system ENERCON inverterGrid frequency 50 Hz / 60 HzSound power level 87.6 - 106.0 dB(A)* Yield and noise-optimised operation. Further modes on request.
ROTORRotor diameter 115.7 mSwept area 10,516 m²Type upwind rotor with active pitch control
TOWERHub height IEC IA IEC IIA IEC IIIA 67 m 122 m 87 m 135 m 92 m 149 m
GENERATORType directly driven, separately excited annular generatorCooling system air/water cooling system
FEATURES STANDARD OPTIONALFACTS and transmission XENERCON SCADA XENERCON storm control XLow radar reflectivity rotor blades XIce detection system XPower curve method
Additional ice detection system X Blade heating system X Hot-Climate X Shadow shutdown X ENERCON SCADA bat protection X STATCOM X Inertia Emulation X Sector management for wind farms X Beacon management for wind farms X
ANNUAL ENERGY YIELD
NEW WEC GENERATION
E-126 EP33,000 kW / 3,500 kW / 4,000 kW
www.enercon.de
3,000
5,000
6,000
4,000
7,000
9,000
10,000
11,000
12,000
13,000
14,000
15,000
16,000
8,000
17,000
MWh per year
Average wind speed at hub height (m/s)
5.1 5.3 5.5 5.7 5.9 6.1 6.3 6.5 6.7 6.9 7.1 7.3 7.5 7.7 7.9 8.1 8.3 8.5
E-126 EP3 / 3,000 kW E-126 EP3 / 3,500 kW E-126 EP3 / 4,000 kW
TECHNICAL DATA
E-126 EP3
The new EP3 range represents a radical cut in ENERCON’s wind energy converter design. Compact and efficient with consistently optimised processes from production, transport and logistics to installation – these are the key characteristics of this WEC generation and ENERCON’s response to new market requirements.
* dependent on hub height
GENERAL Nominal power 3,000 kW / 3,500 kW / 4,000 kWWind class (IEC) IEC IIAWind zone (DIBt) WZ4 GK I + II WZ3 GK I + IITurbine concept gearless, variable speed, full power converterDesign service life 25 yearsCut in wind speed 2.5 m/sCut out wind speed 34 m/sExtreme wind speedat hub height (3-second gust) 59.5 m/sRotational speed 4.4 - 11.7 rpm (3,000 kW) 4.4 - 11.9 rpm (3,500 kW) 4.4 - 12.1 rpm (4,000 kW)Ambient temperaturefor normal operation -10 °C to +40 °CExtreme temperature range -20 °C to +50 °CGrid feed /control system ENERCON inverterGrid frequency 50 Hz / 60 HzSound power level 88.1 - 106.1 dB(A)* Yield and noise-optimised operation. Further modes on request.
ROTORRotor diameter 127 mSwept area 12,668 m²Type upwind rotor with active pitch control
TOWERHub height IEC IA IEC IIA IEC IIIA 86 m 99 m 116 m 135 m
GENERATORType directly driven, separately excited annular generatorCooling system air cooling system
FEATURES STANDARD OPTIONALFACTS and transmission XENERCON SCADA XENERCON storm control XLow radar reflectivity rotor blades XIce detection system XPower curve method
Additional ice detection system X Blade heating system X Hot-Climate X Shadow shutdown X ENERCON SCADA bat protection X STATCOM X Inertia Emulation X Sector management for wind farms X Beacon management for wind farms X
ANNUAL ENERGY YIELD
NEW WEC GENERATION
E-138 EP33,500 kW / 4,200 kW
www.enercon.de
3,000
5,000
6,000
4,000
7,000
9,000
10,000
11,000
12,000
13,000
14,000
15,000
16,000
8,000
17,000
MWh per year
Average wind speed at hub height (m/s)
5.1 5.3 5.5 5.7 5.9 6.1 6.3 6.5 6.7 6.9 7.1 7.3 7.5 7.7 7.9 8.1 8.3 8.5
E-138 EP3 / 3,500 kW E-138 EP3 / 4,200 kW
TECHNICAL DATA
E-138 EP3
The new EP3 range represents a radical cut in ENERCON’s wind energy converter design. Compact and efficient with consistently optimised processes from production, transport and logistics to installation – these are the key characteristics of this WEC generation and ENERCON’s response to new market requirements.
* dependent on hub height
GENERAL Nominal power 3,500 kW / 4,200 kW (E2)Wind class (IEC) IEC IIIAWind zone (DIBt) WZ2 GK II Turbine concept gearless, variable speed, full power converterDesign service life 25 yearsCut in wind speed 2.5 m/sCut out wind speed 34 m/sExtreme wind speedat hub height (3-second gust) 52.5 m/sRotational speed 4.4 / 5 * - 10.5 rpm (3,500 kW) 4.4 / 5 * - 10.8 rpm (4,200 kW) Ambient temperaturefor normal operation -10 °C to +40 °CExtreme temperature range -20 °C to +50 °CGrid feed /control system ENERCON inverterGrid frequency 50 Hz / 60 HzSound power level 93.4 - 106.0 dB(A)* Yield and noise-optimised operation. Further modes on request.
ROTORRotor diameter 138.6 mSwept area 15,085 m²Type upwind rotor with active pitch control
TOWERHub height IEC IA IEC IIA IEC IIIA 81 m 111 m 131 m 160 m
GENERATORType directly driven, separately excited annular generatorCooling system air cooling system
FEATURES STANDARD OPTIONALFACTS and transmission XENERCON SCADA XENERCON storm control XLow radar reflectivity rotor blades XIce detection system XPower curve method
Additional ice detection system X Blade heating system X Hot-Climate X Shadow shutdown X ENERCON SCADA bat protection X STATCOM X Inertia Emulation X Sector management for wind farms X Beacon management for wind farms X
ANNUAL ENERGY YIELD
NEW WEC GENERATION