1
0 First Issue JP3-DI500 /E 04/07/14 Model Dimension :JP3 Projection NYC Dpt of Building Approved Drawing No. DD/MM/YY DESCRIPTION PER QUOTE DRAWING No. REV. Across the Line / 3 Phase Jockey Pump Controller Standard Internal Layout Dimension Enclosure Dimension Door Dimension Anchor Dimension* Maximum Motor Horsepower Main Disconnect Rating Label - All Dimensions are in Inches [Millimeters] - Use Watertight Conduit and Connector Only. - Protect Equipment Against Drilling Chips. Notes: Sensing Line Connection DS ON OFF DANGER D F C ó >@ ò >@ E G A B 3 8 "[9] x4 HAND AUTO - Door Swing Equal to Door Width ENCLOSED INDUSTRIAL CONTROL PANEL Laboratories Inc. No. AC-XXX LISTED Underwriters NYC - Standard NEMA: NEMA 2 PT1 OL1 C1 XTR1 FU1 3L2 1L1 5L3 2T1 4T2 6T3 DS - Standard Paint : Textured Red RAL 3002. 1 Dimension Table and Notes 17/10/14 Manufacturer reserves the right to modify this drawing without notice. Contact manufacturer for "As Built" drawing. -*Dimension may change depending on option required. Consult Factory for exact dimensions. - Drawing for information only. A X B X C ;;ò ;;ò TBD 10-ǫ"X12-ǫ" ò;ò TBD TBD D X E F X G 200-208V 3HP 5HP 10HP 20HP 220-240V 3HP 380-416V 7.5HP 10HP 20HP 40HP 440-480V 7.5HP 10HP 20HP 50HP 575-600V 10HP 15HP 25HP 50HP 25HP 50HP 60HP 60HP 5HP 10HP 20HP 30HP ;;ò 10-ǫ"X12-ǫ" ;;ò 10-ǫ"X12-ǫ" Built to the latest edition of the UL 508A & CSA C22.2 No.14 1/4 " M.NPT 2 IPD+ R221B 23/01/14 3 4 5 6 7 2 G H 0 1 8 B C D E F I A 3 4 5 6 7 2 0 1 8 G H I A B C D E F

Dwg JP Controller - For Fuel Handling System

Embed Size (px)

DESCRIPTION

RT

Citation preview

Page 1: Dwg JP Controller - For Fuel Handling System

0 First Issue

JP3-DI500 /E

04/07/14

Model

Dimension

:JP3

Projection

NYC

Dpt of Building

Approved

Drawing No.

DD/MM/YYDESCRIPTION

PER QUOTE DRAWING No.

REV.Across the Line / 3 Phase

Jockey Pump Controller

Standard Internal Layout

Dimension Enclosure Dimension Door Dimension Anchor

Dimension*

Maximum Motor Horsepower

Main Disconnect

Rating

Label

- All Dimensions are in Inches [Millimeters]

- Use Watertight Conduit and Connector Only.

- Protect Equipment Against Drilling Chips.

Notes:

Sensing Line

Connection

DS

ON

OF

F

DANGER

D

FC

2-¼" [58]

4-½" [115]

E

G

A

B

Ø

3

8 "[9] x4

HAND AUTO

G

Y

R

GG

- Door Swing Equal to Door Width

ENCLOSED INDUSTRIAL CONTROL PANEL

Laboratories Inc.

No. AC-XXX

LISTED

Underwriters

NYC

- Standard NEMA: NEMA 2

PT1

OL1

C1

XT

R1

FU1

3L21L1 5L3

2T1 4T2 6T3

DS

- Standard Paint : Textured Red RAL 3002.

1 Dimension Table and Notes 17/10/14

Manufacturer reserves the right to modify this drawing without notice.

Contact manufacturer for "As Built" drawing.

-*Dimension may change depending on option required. Consult Factory for exact

dimensions.

- Drawing for information only.

A X B X C

10"X12"X6-½"

16"X16"X7-½"

TBD

10-⅝"X12-⅝"

16-½"X16-½"

TBD

8"X12-¾"

14"X16-¾"

TBD

D X E F X G200-208V

3HP

5HP

10HP

20HP

220-240V

3HP

380-416V

7.5HP

10HP

20HP

40HP

440-480V

7.5HP

10HP

20HP

50HP

575-600V

10HP

15HP

25HP

50HP

25HP 50HP 60HP 60HP

5HP

10HP

20HP

30HP

10"X12"X6-½" 10-⅝"X12-⅝" 8"X12-¾"

10"X12"X6-½" 10-⅝"X12-⅝" 8"X12-¾"

Built to the latest edition of the UL 508A & CSA C22.2 No.14

1/4 " M.NPT

2 IPD+ R221B 23/01/14

3 4 5 6 72

G

H

0 1 8

B

C

D

E

F

I

A

3 4 5 6 720 1 8

G

H

I

A

B

C

D

E

F