WWW.HOTSTART.COM DV Coolant/Lube Oil Heating System APPLICATION FEATURES SPECIFICATIONS DIMENSIONS & WEIGHT Customer Service 509-536-8660 DS-DV-E 2012-10/rev0 Height (H) Width (W) Depth (D) Weight 53” 26.9” 14” 405 lbs. 1346mm 683mm 356mm 184 kg The DV was developed to pre-heat locomotive prime movers as well as diesel and gas engines for stationary land power, marine, large mining and construction equipment. The HOTSTART DV is a complete, packaged dual heating system with thermocouples, pump and all required controls. It heats and circulates coolant and lube oil throughout the entire engine and cooling system. The DV heats engines up to 300L displacement at 120°F over ambient temperature. The system features a text display which displays system diagnostics and allows operators to adjust and monitor water and oil temperature. • Heating Fluid: Coolant and Oil • Coolant Heat Power: 12, 18, 24, 30 and 36kW • Oil Heat Power: 6, 9, 12kW • Rated Voltage: 208, 240, 480, 575V (3Ø 60Hz) 220, 380, 400, 415V (3Ø 50Hz) • Tank Material: Steel • T-Stat, coolant: Adj. 60° - 160°F (16° - 71°C) • T-Stat, oil: Adj. 80° - 140°F (27° - 60°C) • Ingress Protection: IP54, NEMA 12 & 13 • Hi-Limit Cutout: 200°F (94°C) • Fluid Capacity, oil/coolant: 1.75 gl (6.6L) • Continuous flow monitoring • 24VDC ON/OFF remote control • CE compliant to LVD (optional) • Coolant Pump Power: 1HP (0.75kW) • Oil Pump Power: 1 or 2HP available (0.75 or 1.5kW) • Coolant Flow: 40GPM @ 40ft head (9m 3 /hr @ 1.2 bar) • Oil Flow: 10, 20GPM (2.3, 4.6 m 3 /hr) • Max Pressure: 125PSI (8.61 bar) • Pressure Loss: 5PSI (0.35 bar) • Pressure Relief, coolant: 90PSI (6.2 bar) • Pressure Relief, oil: 50PSI (3.5 bar) - internal • Inlet/Outlet, coolant: 1.25”NPT inlet, 1”NPT outlet • Inlet/Outlet, oil: 1”NPT (10GPM), 1.5”NPT (20GPM), inlet 1”NPT outlet

DV Coolant/Lube Oil Heating System - HOTSTART … · DV Coolant/Lube Oil Heating System ... The DV was developed to pre-heat locomotive prime movers as well as diesel ... It heats

  • Upload
    buidat

  • View
    218

  • Download
    1

Embed Size (px)

Citation preview

Page 1: DV Coolant/Lube Oil Heating System - HOTSTART … · DV Coolant/Lube Oil Heating System ... The DV was developed to pre-heat locomotive prime movers as well as diesel ... It heats

WWW.HOTSTART.COM

DV Coolant/Lube Oil Heating System

APPLICATION

FEATURES

SPECIFICATIONS

DIMENSIONS & WEIGHT

Customer Service 509-536-8660

DS-DV-E2012-10/rev0

Height (H) Width (W) Depth (D) Weight 53” 26.9” 14” 405 lbs. 1346mm 683mm 356mm 184 kg

The DV was developed to pre-heat locomotive prime movers as well as diesel and gas

engines for stationary land power, marine, large mining and construction equipment.

The HOTSTART DV is a complete, packaged dual heating system with thermocouples, pump and

all required controls. It heats and circulates coolant and lube oil throughout the entire engine

and cooling system. The DV heats engines up to 300L displacement at 120°F over ambient

temperature. The system features a text display which displays system diagnostics and allows

operators to adjust and monitor water and oil temperature.

• Heating Fluid: Coolant and Oil

• Coolant Heat Power: 12, 18, 24, 30 and 36kW

• Oil Heat Power: 6, 9, 12kW

• Rated Voltage: 208, 240, 480, 575V (3Ø 60Hz)

220, 380, 400, 415V (3Ø 50Hz)

• Tank Material: Steel

• T-Stat, coolant: Adj. 60° - 160°F (16° - 71°C)

• T-Stat, oil: Adj. 80° - 140°F (27° - 60°C)

• Ingress Protection: IP54, NEMA 12 & 13

• Hi-Limit Cutout: 200°F (94°C)

• Fluid Capacity, oil/coolant: 1.75 gl (6.6L)

• Continuous fl ow monitoring

• 24VDC ON/OFF remote control

• CE compliant to LVD (optional)

• Coolant Pump Power: 1HP (0.75kW)

• Oil Pump Power: 1 or 2HP available (0.75 or 1.5kW)

• Coolant Flow: 40GPM @ 40ft head (9m3/hr @ 1.2 bar)

• Oil Flow: 10, 20GPM (2.3, 4.6 m3/hr)

• Max Pressure: 125PSI (8.61 bar)

• Pressure Loss: 5PSI (0.35 bar)

• Pressure Relief, coolant: 90PSI (6.2 bar)

• Pressure Relief, oil: 50PSI (3.5 bar) - internal

• Inlet/Outlet, coolant: 1.25”NPT inlet, 1”NPT outlet

• Inlet/Outlet, oil: 1”NPT (10GPM), 1.5”NPT (20GPM), inlet

1”NPT outlet

Page 2: DV Coolant/Lube Oil Heating System - HOTSTART … · DV Coolant/Lube Oil Heating System ... The DV was developed to pre-heat locomotive prime movers as well as diesel ... It heats

WWW.HOTSTART.COM5723 E Alki, Spokane WA 99212

DS-DV-E2012-10/rev0

Engine Sizecubic inch, liter

Oil Volumegallons, liter

Part Number3 phase, 60 Hz

WaterkW

OilkW

VoltsTotalAmps

WaterHP/GPM

OilHP/GPM

4000 - 9000 cid65-150 l

100-180 gl380-680 l

DV3180-0602DV3180-0604DV3180-0605

181818

666

240480575

65.833.628.0

1 / 401 / 401 / 40

1 / 101 / 101 / 10

9000 - 12000 cid150-200 l

100-180 gl380-680 l

DV3240-0604DV3240-0605

2424

66

480575

40.832.9

1 / 401 / 40

1 / 101 / 10

12000 - 15000 cid200-250 l

180-265 gl680-1000 l

DV3300-0904DV3300-0905

3030

99

480575

53.244.1

1 / 401 / 40

2 / 202 / 20

15000 - 18000 cid250-300 l

265-360 gl1000-1350 l

DV3360-1204DV3360-1205

3636

1212

480575

62.753.0

1 / 401 / 40

2 / 202 / 20

DV Coolant/Lube Oil Heating System