SS-DTH3 www.daikinac.com 1/18 Supersedes 12/17 3 - 5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF Cooling Capacity: 35,000 - 60,000 BTU/h Heang Capacity: 32,800 - 55,500 BTU/h DTH Commercial Contents Nomenclature ............................... 2 Product Specificaons .................. 4 Expanded Cooling Data ................. 6 Airflow Data ................................ 18 Expanded Heang Data ............. 21 Crankcase Heater ........................ 23 Heat Kit Electrical Data .............. 24 Electrical Data ............................ 25 Dimensions.................................. 26 Wiring Diagram .......................... 30 – for Models with DDC Controls ...... 32 Accessories ................................. 37 * Complete warranty details available from your local dealer or at www.daikincomfort.com. Standard Features High-efficiency scroll compressor Copper tube / aluminum fin coils High- and low-pressure switches Refrigerant accumulator Contactor with lugs High-capacity, steel-cased filter drier Heater kits with single-point entry 24-volt terminal strip Converble airflow orientaon Easy to service Built-in filter rack with standard 2” filters Boom ulity entry AHRI Cerfied; ETL Listed 3-phase unit meets the performance specified as of 1/1/2015 in Table 6.8.1-2 of ASHRAE Standard 90.1-2013 Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish • Full Perimeter Rail • Sloped drain pan

DTH Commercial

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DTH Commercial

SS-DTH3 www.daikinac.com 1/18Supersedes 12/17

3 - 5 Tons Heat Pumps15 SEER Up to 13.0 EER / 8.2 HSPF

Cooling Capacity: 35,000 - 60,000 BTU/h

Heating Capacity: 32,800 - 55,500 BTU/h

DTH Commercial

■ ContentsNomenclature ...............................2Product Specifications ..................4Expanded Cooling Data .................6Airflow Data ................................18Expanded Heating Data .............21Crankcase Heater ........................23Heat Kit Electrical Data ..............24 Electrical Data ............................25Dimensions ..................................26Wiring Diagram ..........................30 – for Models with DDC Controls ......32Accessories .................................37

* Complete warranty details available from your local dealer or at www.daikincomfort.com.

■ Standard Features• High-efficiency scroll compressor• Copper tube / aluminum fin coils• High- and low-pressure switches• Refrigerant accumulator• Contactor with lugs• High-capacity, steel-cased filter drier• Heater kits with single-point entry• 24-volt terminal strip• Convertible airflow orientation• Easy to service• Built-in filter rack with standard 2” filters• Bottom utility entry• AHRI Certified; ETL Listed• 3-phase unit meets the performance

specified as of 1/1/2015 in Table 6.8.1-2 of ASHRAE Standard 90.1-2013

■ Cabinet Features• Heavy-gauge, galvanized-steel cabinet

with UV-resistant powder-paint finish• Full Perimeter Rail• Sloped drain pan

Page 2: DTH Commercial

2 www.daikinac.com SS-DTH3

Nomenclature

D T H 060 090 3 V * * * A *1 2 3 4,5,6 7,8,9 10 11 12 13 14 15 16

Revision LevelsMajor & Minor

Brand Factory-Installed OptionsD Daikin X No Options

A Non-powered convenience outletConfiguration B Powered convenience outletC Standard Efficiency (6 - 25 Tons) C Low-ambient kitS Standard Efficiency (3 - 5 Tons) D Return air smoke detectorT High Efficiency (3 - 5 Tons) E Supply air smoke detector

F Non-powered convenience outlet; Application Low-ambient kitC Cooling1 G Non-powered convenience outlet; G Gas Heat Return air smoke detectorH Heat Pump1 H Non-powered convenience outlet;

Supply air smoke detectorNominal Cooling Capacity J Non-powered convenience outlet;036 3 Tons 102 8½ Tons 300 25 Tons Return & Supply air smoke detectors048 4 Tons 120 10 Tons K Non-powered convenience outlet;060 5 Tons 150 12½ tons Low-ambient kit; Supply air smoke detector072 6 Tons 180 15 Tons L Non-powered convenience outlet; 090 7½ Tons 240 20 Tons Low-ambient kit

Return & Supply air smoke detectorsNominal Heating Capacity M Powered convenience outlet;

Gas/Electric A/C H/P Factory-Installed Electric Heat Low-ambient kit045 45,000 BTU/h XXX No Heat N Powered convenience outlet;090 90,000 BTU/h 010 10 kW 030 30 kW Return air smoke detector115 115,000 BTU/h 015 15 kW 031 30 kW O Powered convenience outlet;140 140,000 BTU/h 016 15 kW 045 45 kW Return & Supply air smoke detectors210 210,000 BTU/h 018 18 kW 046 45 kW P Powered convenience outlet;350 350,000 BTU/h 020 20 kW 060 60 kW Supply air smoke detector400 400,000 BTU/h 025 25 kW Q Powered convenience outlet; Low-ambient

See product specifications for heat size(s) available for each capacity. kit; Return air smoke detectorR Powered convenience outlet; Low-ambient

Voltage kit; Supply air smoke detector1 208-230/1/60 (DS* & DT* 3-5 Tons models only) 4 460/3/60 T Powered convenience outlet; Low-ambient3 208-230/3/60 7 575/3/60 kit; Return & Supply air smoke detectors

U Non-powered convenience outlet;Supply Fan/Drive Type/Motor Low-ambient kit; Return air smoke detectorB Belt Drive (3-5 Tons single speed models only) V Two-Speed Belt Drive V Low-ambient kit; Return air smoke detectorD Direct Drive (3-5 Tons single speed models only) (6-25 Tons only) W Low-ambient kit; Supply air smoke detectorH High Static (3-5 Tons single-speed Belt W High Static (6-25 Tons Y Low-ambient kit; Return & Supply

Drive models only) two-speed Belt Drive air smoke detectorsmodels only) Z Return & Supply air smoke detectors

Factory-Installed OptionsA Ultra Low-Leak Downflow Economizer R Ultra Low-Leak Downflow Economizer;B DDC-BACnet protocol DDC-BACnet protocol; F Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) Factory-Installed Options

DDC-BACnet protocol V Low-Leak Downflow Economizer X Standard Aluminized Heat ExchangerH Disconnect Switch (non-fused) W Low-Leak Downflow Economizer S Stainless-Steel Heat ExchangerJ Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) D Hinged Panels

Disconnect Switch (non-fused) X No Options K Stainless-Steel Heat Exchanger; M Disconnect Switch (non-fused); DDC-BACnet protocol Hinged Panels

B Phase MonitorNote: Not all options available for all products. J Stainless Steel Heat Exchanger; Phase Monitor

1 X= No Options in character 13th M Hinged Panel; Phase MonitorL Stainless-Steel Heat Exchanger;

Hinged Panels; Phase Monitor

Page 3: DTH Commercial

SS-DTH3 www.daikinac.com 3

Nomenclature

Factory-Installed Options• Stainless-Steel Heat Exchanger (Gas units only): A tubular heat exchanger made of 409-type stainless steel is installed in the unit.• Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the 3- to 6-ton units, cooling operation is extended

from 60°F ambient temperature to 35°F outside air temperature. On 7½ -20 ton units, cooling operation is extended from 35°F ambient temperature to 0°F outside air temperature. For 25 ton units, cooling operation is extended from 24°F ambient temperature to 0°F outside air temperature.

• Economizers (Downflow): Based on air conditions, can provide outside air to cool the space.• Electric Heat Kits (AC and heat pump units only): Available in all voltage options.• Non-powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs

power to the outlet.• Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit. When a factory-installed powered

convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.2A/6.5Afor 208/230V units, increase by 3.3A for 460V units, and by 2.6A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly.

• Disconnect Switch (non-fused; 3-phase units only): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning (DSC units) and heat pump models (DSH units), the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position.

• Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit.• Hinged Access Panels: Allows access to unit’s major components. Combined with latches for easy access to control box, compressor,

filters and blower motor. Available on all units.• Two-speed indoor fan blower models are available on 6, 7½, 8½, 10, 12½, 15, 20 & 25 ton units. Section 6.4.3.10.b of ASHRAE Standard

90.1-2010 and Section 6.5.3.2.1.a of ASHRAE Standard 90.1-2013 require a minimum of two fan speeds. Section 140.4(m)1 of California Energy Commission Title 24 2013 contains a similar provision. When the units with the two-speed indoor fan blowers operate on a call for the first stage of cooling, the fan operates at low speed, which is 66% of full speed. When the units operate on a call for the second stage of cooling, the fan operates at full speed. In heating operation, the fan operates at full speed. During ventilation operation, the fan operates at low speed.

• Phase Monitor: Phase monitor (3 phase only), available for 3 - 25 ton DS, DC and DT series models. Phase monitor shall provide protection for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator.

• DDC Controller: DDC communicating controller, available for 3 - 25 ton DS, DC and DT series models with on-board BACnet® communication interface.

Page 4: DTH Commercial

4 www.daikinac.com SS-DTH3

Product Specifications

DTH036***1D***A*

DTH048***1D***A*

DTH060***1D***A*

Cooling CapacityTotal BTU/h 35,400 46,500 59,500Sensible BTU/h 28,000 36,000 44,000SEER / EER 15.0 / 12.5 15.0 / 12.0 15.0 / 12.0Decibels 78 78 78ARI Reference #s 8101150 8101152 8101154

Heating CapacityBTU/h / COP (47° F) 34,800/ 4.0 44,500 / 3.8 55,500 / 3.8BTU/h / COP (17° F) 18,000/ 2.4 24,000 / 2.4 31,200 / 2.4HSPF 8.0 8.0 8.0Evaporator Motor / CoilMotor Type Direct Drive Direct Drive Direct DriveIndoor Nominal CFM 1,200 1,600 2,000Motor Speed Tap (Cooling) T3 T3 T3Horsepower - RPM ½ - 750 1 - 750 1 - 950Piston Size (Cooling) 0.068 0.076 0.086Filter Size (Qty) (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 16" x 20" x 2"Drain Size (NPT) ¾" ¾" ¾"R-410A Refrigerant Charge Cir #1 (oz.) 170 158 240Evaporator Coil Face Area (ft²) 7.8 7.8 8.9Rows Deep/ Fins per Inch 4/16 4 / 16 4 / 16Tube Diameter - Material 5/16 - Copper 5/16 - Copper 3/8 - CopperEvaporator Fan# of Wheels (D x W) 1 (10" x 9") (11" X 10") 1 (11" X 10") 1Motor Sheave --- --- ---Blower Sheave / Belt --- --- ---Condenser Fan / CoilQuantity of Condenser Fan Motors 1 1 1Horsepower - RPM ¼ / 1,090 ¼ / 1,090 ⅓ / 1,090Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4Outdoor Nominal CFM 3,800 3,800 4,200Face Area (ft²) 17.0 17 19Rows Deep / Fins per Inch 2 / 18 2 / 18 2 / 20Piston Size (Heating) 0.055 0.059 0.065Tube Diameter - Material 5/16 - Copper 5/16 - Copper 3/8 - CopperCompressorQuantity / Type/ Stage 1 / Scroll/ 1 1 / Scroll/ 1 1 / Scroll/ 1Compressor RLA / LRA 14.1 / 77.0 19.9 / 109 25.0/134.0Electrical DataVoltage - Phase - Frequency 208/230-1-60 208/230-1-60 208/230-1-60Indoor Blower HP / FLA ½ / 3.9 1.0 / 6.9 1.0 / 6.9Max External Static 0.5" 0.6" 0.9Outdoor Fan HP / FLA ¼ / 1.4 ¼ / 1.4 ⅓ / 2.0Total Unit Amps 19.4 28.2 33.9Min. Circuit Ampacity¹ 22.9 / 22.9 33.1 / 33.1 40.2 / 40.2Max. Overcurrent Protection (amps)² 35 / 35 50 / 50 60 / 60Power Supply Conduit Hole 1.125 1.125 1.125Low Voltage Conduit Hole ½" ½" ½"Operating Weight (lbs) 520 549 583Ship Weight (lbs) 548 577 612

¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.

Page 5: DTH Commercial

SS-DTH3 www.daikinac.com 5

Product Specifications

DTH036***3D***A*

DTH048***3D***A*

DTH060***3D***A*

Cooling CapacityTotal BTU/h 35,000 47,000 60,000Sensible BTU/h 25,000 33,600 42,900SEER / EER 15.0/ 13.0 15.0/ 12.5 15.0/ 12.5Decibels 78 78 78ARI Reference #s 8965282 8965283 8965284Heating CapacityBTU/h / COP (47° F) 32,800 / 3.6 44,000 / 3.8 55,000 / 3.6BTU/h / COP (17° F) 18,000 / 2.3 23,600 / 2.4 30,800 / 2.4HSPF 8.0 8.0 8.2Evaporator Motor / CoilMotor Type Direct Drive Direct Drive Direct DriveIndoor Nominal CFM 1,200 1,600 2,000Motor Speed Tap (Cooling) T3 T3 T3Horsepower ½ 1 1Piston Size (Cooling) 0.068 0.076 0.086Filter Size (Qty) (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 16" x 20" x 2"Drain Size (NPT) ¾" ¾" ¾"R-410A Refrigerant Charge Cir #1 (oz.) 170 168 254Evaporator Coil Face Area (ft²) 7.8 7.8 8.9Rows Deep/ Fins per Inch 4/16 4 / 16 4 / 16Tube Diameter - Material 5/16 - Copper 5/16 - Copper 3/8 - CopperEvaporator Fan# of Wheels (D x W) 1 (10" x 9") (11" X 10") 1 (11" X 10") 1Motor Sheave --- --- ---Blower Sheave / Belt --- --- ---Condenser Fan / CoilQuantity of Condenser Fan Motors 1 1 1Horsepower - RPM ¼ / 1,090 ¼ / 1,090 ⅓ / 1,090Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4Outdoor Nominal CFM 3,800 3,800 4,200Face Area (ft²) 17.0 17.0 19.0Rows Deep / Fins per Inch 2 / 18 2 / 18 2 / 20Piston Size (Heating) 0.049 0.059 0.062Tube Diameter - Material 5/16 - Copper 5/16 - Copper 3/8 - CopperCompressorQuantity / Type/ Stage 1 / Scroll/ 1 1 / Scroll/ 1 1 / Scroll/ 1Compressor RLA / LRA 9.0/71 13.1/83.1 15.9/110Electrical DataVoltage - Phase - Frequency 208/230-3-60 208/230-3-60 208/230-3-60Indoor Blower HP / FLA 1/2 / 3.9 1 / 6.9 1 / 6.9Max External Static 0.5" 0.6" 0.9Outdoor Fan HP / FLA ¼ / 1.4 ¼ / 1.4 1/3 / 2.3Total Unit Amps 14.3 21.4 25.1Min. Circuit Ampacity¹ 16.5 / 16.5 24.7 / 24.7 29.1 / 29.1Max. Overcurrent Protection (amps)² 25 / 25 35 / 35 45 / 45Power Supply Conduit Hole 1.125 1.125 1.125Low Voltage Conduit Hole ½" ½" ½"Operating Weight (lbs) 520 549 583Ship Weight (lbs) 548 577 612

¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Note: Always check the S&R plate for electrical data on the unit being installed.

Page 6: DTH Commercial

6 www.daikinac.com SS-DTH3

Expanded Cooling Data — 3 Tons (1-Phase Models)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

1350

MBh

34.7

36.0

39.4

-33

.935

.138

.5-

33.1

34.3

37.6

-32

.333

.436

.6-

30.7

31.8

34.8

-28

.429

.432

.2-

S/T

0.75

0.63

0.44

-0.

780.

650.

45-

0.80

0.67

0.46

-0.

830.

690.

48-

0.86

0.72

0.50

-0.

860.

720.

50-

∆T18

1512

-18

1612

-18

1612

-18

1612

-18

1512

-17

1411

-

kW2.

272.

312.

37-

2.42

2.47

2.54

-2.

552.

602.

68-

2.67

2.73

2.81

-2.

782.

832.

92-

2.86

2.92

3.01

-

HI P

R22

524

225

5-

252

271

287

-28

730

932

6-

327

352

371

-36

739

541

8-

406

437

461

-LO

PR

111

118

129

-11

712

513

6-

122

129

141

-12

813

614

8-

134

143

156

-13

914

716

1-

1200

MBh

33.7

34.9

38.2

-32

.934

.137

.4-

32.1

33.3

36.5

-31

.332

.535

.6-

29.8

30.8

33.8

-27

.628

.631

.3-

S/T

0.72

0.60

0.42

-0.

740.

620.

43-

0.76

0.64

0.44

-0.

790.

660.

46-

0.82

0.68

0.47

-0.

820.

690.

48-

∆T19

1612

-19

1612

-19

1612

-19

1612

-19

1612

-17

1511

-

kW2.

252.

292.

36-

2.40

2.45

2.52

-2.

542.

592.

66-

2.65

2.71

2.79

-2.

752.

812.

89-

2.84

2.90

2.99

-

HI P

R22

223

925

3-

250

269

284

-28

430

632

3-

323

348

368

-36

439

241

3-

402

433

457

-LO

PR

110

117

127

-11

612

313

5-

120

128

140

-12

713

514

7-

133

141

154

-13

714

615

9-

1050

MBh

31.1

32.2

35.3

-30

.431

.534

.5-

29.6

30.7

33.7

-28

.930

.032

.8-

27.5

28.5

31.2

-25

.426

.428

.9-

S/T

0.69

0.58

0.40

-0.

720.

600.

42-

0.74

0.61

0.43

-0.

760.

630.

44-

0.79

0.66

0.46

-0.

800.

660.

46-

∆T19

1612

-19

1713

-19

1713

-19

1713

-19

1612

-18

1512

-

kW2.

202.

242.

30-

2.35

2.39

2.46

-2.

482.

532.

60-

2.60

2.65

2.72

-2.

692.

752.

83-

2.78

2.83

2.92

-

HI P

R21

623

224

5-

242

261

275

-27

529

631

3-

314

338

356

-35

338

040

1-

390

420

443

-LO

PR

106

113

124

-11

212

013

1-

117

124

136

-12

313

114

3-

129

137

149

-13

314

215

5-

75

1350

MBh

35.3

36.3

39.3

42.2

34.5

35.5

38.4

41.2

33.6

34.6

37.5

40.2

32.8

33.8

36.6

39.3

31.2

32.1

34.7

37.3

28.9

29.7

32.2

34.5

S/T

0.86

0.77

0.58

0.37

0.89

0.79

0.60

0.39

0.91

0.81

0.62

0.40

0.94

0.84

0.64

0.41

0.97

0.87

0.66

0.42

0.98

0.88

0.67

0.43

∆T21

1916

1121

1916

1121

1916

1121

1916

1121

1916

1119

1815

10

kW2.

282.

322.

392.

462.

442.

482.

552.

632.

572.

622.

702.

782.

692.

752.

832.

922.

802.

852.

943.

032.

892.

943.

033.

13

HI P

R22

724

425

826

925

527

428

930

229

031

232

934

333

035

537

539

137

139

942

244

041

044

146

648

6LO

PR

112

119

130

138

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

1200

MBh

34.2

35.3

38.2

41.0

33.5

34.4

37.3

40.0

32.7

33.6

36.4

39.1

31.9

32.8

35.5

38.1

30.3

31.2

33.7

36.2

28.0

28.9

31.2

33.5

S/T

0.82

0.73

0.55

0.36

0.85

0.76

0.57

0.37

0.87

0.78

0.59

0.38

0.90

0.80

0.61

0.39

0.93

0.83

0.63

0.40

0.94

0.84

0.63

0.41

∆T21

2016

1122

2016

1122

2016

1122

2016

1122

2016

1120

1915

10

kW2.

272.

312.

372.

442.

422.

472.

542.

612.

552.

602.

682.

762.

672.

732.

812.

892.

782.

832.

923.

012.

862.

923.

013.

10

HI P

R22

524

225

526

625

227

128

729

928

730

932

634

032

735

237

138

736

839

641

843

640

643

746

148

1LO

PR

111

118

129

137

117

125

136

145

122

129

141

151

128

136

149

158

134

143

156

166

139

147

161

171

1050

MBh

31.6

32.5

35.2

37.8

30.9

31.8

34.4

36.9

30.1

31.0

33.6

36.1

29.4

30.3

32.8

35.2

27.9

28.8

31.1

33.4

25.9

26.6

28.8

31.0

S/T

0.79

0.70

0.53

0.34

0.82

0.73

0.55

0.36

0.84

0.75

0.57

0.36

0.86

0.77

0.58

0.38

0.90

0.80

0.61

0.39

0.90

0.81

0.61

0.39

∆T22

2016

1122

2017

1122

2017

1222

2017

1222

2017

1120

1915

11

kW2.

222.

262.

322.

392.

372.

412.

482.

552.

502.

552.

622.

702.

612.

672.

742.

832.

712.

772.

852.

942.

802.

852.

943.

03

HI P

R21

823

524

825

824

526

327

829

027

829

931

633

031

734

136

037

635

738

440

542

339

442

444

846

7LO

PR

108

114

125

133

114

121

132

141

118

126

137

146

124

132

144

153

130

138

151

161

134

143

156

166

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Desig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

1350

MBh

35.9

36.7

39.2

41.9

35.1

35.8

38.3

40.9

34.2

35.0

37.4

40.0

33.4

34.1

36.5

39.0

31.7

32.4

34.6

37.0

29.4

30.0

32.1

34.3

S/T

0.94

0.88

0.72

0.5

1.00

0.91

0.74

0.6

1.00

0.94

0.76

0.6

1.00

0.97

0.79

0.6

1.00

1.00

0.82

0.6

1.00

1.00

0.82

0.6

∆T23

2219

1524

2219

1523

2219

1523

2220

1622

2219

1520

2018

14.4

kW2.

302.

342.

412.

52.

452.

502.

572.

62.

592.

642.

722.

82.

712.

772.

852.

92.

822.

882.

963.

12.

912.

973.

063.

2

HI P

R22

924

726

127

225

727

729

230

529

331

533

334

733

335

937

939

537

540

442

644

441

444

647

149

1LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

1200

MBh

34.9

35.6

38.1

40.7

34.0

34.8

37.2

39.7

33.2

34.0

36.3

38.8

32.4

33.1

35.4

37.8

30.8

31.5

33.6

36.0

28.5

29.2

31.2

33.3

S/T

0.90

0.84

0.68

0.5

0.93

0.87

0.71

0.5

0.95

0.89

0.73

0.5

0.98

0.92

0.75

0.6

1.00

0.96

0.78

0.6

1.00

0.96

0.78

0.6

∆T24

2320

1624

2320

1624

2320

1624

2320

1624

2320

1622

2219

15.0

kW2.

282.

322.

392.

52.

442.

482.

552.

62.

572.

622.

702.

82.

692.

752.

832.

92.

802.

852.

943.

02.

892.

943.

033.

1

HI P

R22

724

425

826

925

527

429

030

229

031

232

934

333

035

537

539

137

140

042

244

041

044

146

648

6LO

PR

112

119

130

139

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

1050

MBh

32.2

32.9

35.1

37.5

31.4

32.1

34.3

36.7

30.7

31.3

33.5

35.8

29.9

30.6

32.7

34.9

28.4

29.1

31.0

33.2

26.3

26.9

28.8

30.7

S/T

0.86

0.81

0.66

0.5

0.90

0.84

0.68

0.5

0.92

0.86

0.70

0.5

0.95

0.89

0.72

0.5

0.98

0.92

0.75

0.6

0.99

0.93

0.76

0.6

∆T24

2320

1625

2421

1625

2421

1625

2421

1724

2320

1623

2219

15.2

kW2.

232.

272.

342.

42.

382.

432.

502.

62.

522.

572.

642.

72.

632.

692.

772.

82.

732.

792.

873.

02.

822.

882.

963.

1

HI P

R22

023

725

026

124

726

628

129

328

130

231

933

332

034

436

437

936

038

840

942

739

842

845

247

2LO

PR

109

116

126

134

115

122

133

142

119

127

139

148

125

133

146

155

131

140

152

162

136

144

158

168

85

1350

MBh

36.5

37.2

39.0

41.6

35.7

36.4

38.1

40.6

34.8

35.5

37.2

39.7

34.0

34.6

36.3

38.7

32.3

32.9

34.5

36.8

29.9

30.5

31.9

34.1

S/T

0.98

0.95

0.86

0.7

1.00

0.98

0.89

0.7

1.00

1.00

0.91

0.7

1.00

1.00

0.94

0.8

1.00

1.00

0.98

0.8

1.00

1.00

0.98

0.8

∆T24

2423

2024

2423

2024

2423

2023

2423

2022

2223

2020

2121

18.5

kW2.

312.

362.

422.

52.

472.

522.

592.

72.

612.

662.

742.

82.

742.

792.

873.

02.

842.

902.

993.

12.

932.

993.

083.

2

HI P

R23

224

926

327

526

028

029

530

829

631

833

635

033

736

238

339

937

940

843

044

941

845

047

549

6LO

PR

114

122

133

141

121

128

140

149

125

133

146

155

132

140

153

163

138

147

160

171

143

152

166

177

1200

MBh

35.5

36.2

37.9

40.4

34.6

35.3

37.0

39.5

33.8

34.5

36.1

38.5

33.0

33.6

35.2

37.6

31.3

31.9

33.5

35.7

29.0

29.6

31.0

33.1

S/T

0.94

0.91

0.82

0.7

0.97

0.94

0.85

0.7

1.00

0.96

0.87

0.7

1.00

0.99

0.90

0.7

1.00

1.00

0.93

0.8

1.00

1.00

0.94

0.8

∆T26

2524

2126

2524

2126

2524

2125

2624

2124

2424

2122

2322

19.3

kW2.

302.

342.

412.

52.

452.

502.

572.

62.

592.

642.

722.

82.

712.

772.

852.

92.

822.

882.

963.

12.

912.

973.

063.

2

HI P

R22

924

726

127

225

727

729

230

529

331

533

334

733

335

937

939

537

540

442

644

441

444

647

149

1LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

1050

MBh

32.7

33.4

34.9

37.3

32.0

32.6

34.1

36.4

31.2

31.8

33.3

35.6

30.5

31.0

32.5

34.7

28.9

29.5

30.9

33.0

26.8

27.3

28.6

30.5

S/T

0.91

0.87

0.79

0.6

0.94

0.91

0.82

0.7

0.96

0.93

0.84

0.7

0.99

0.96

0.86

0.7

1.00

0.99

0.90

0.7

1.00

1.00

0.91

0.7

∆T26

2624

2126

2624

2126

2624

2126

2625

2125

2624

2123

2423

19.6

kW2.

252.

292.

352.

42.

402.

452.

522.

62.

542.

582.

662.

72.

652.

712.

792.

92.

752.

812.

893.

02.

842.

902.

993.

1

HI P

R22

223

925

326

425

026

928

429

628

430

532

333

632

334

836

738

336

439

141

343

140

243

245

747

6LO

PR

110

117

127

136

116

123

135

143

120

128

140

149

127

135

147

157

133

141

154

164

137

146

159

170

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 7: DTH Commercial

SS-DTH3 www.daikinac.com 7

Expanded Cooling Data — 3 Tons (1-Phase Models) (cont.)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

1350

MBh

34.7

36.0

39.4

-33

.935

.138

.5-

33.1

34.3

37.6

-32

.333

.436

.6-

30.7

31.8

34.8

-28

.429

.432

.2-

S/T

0.75

0.63

0.44

-0.

780.

650.

45-

0.80

0.67

0.46

-0.

830.

690.

48-

0.86

0.72

0.50

-0.

860.

720.

50-

∆T18

1512

-18

1612

-18

1612

-18

1612

-18

1512

-17

1411

-

kW2.

272.

312.

37-

2.42

2.47

2.54

-2.

552.

602.

68-

2.67

2.73

2.81

-2.

782.

832.

92-

2.86

2.92

3.01

-

HI P

R22

524

225

5-

252

271

287

-28

730

932

6-

327

352

371

-36

739

541

8-

406

437

461

-LO

PR

111

118

129

-11

712

513

6-

122

129

141

-12

813

614

8-

134

143

156

-13

914

716

1-

1200

MBh

33.7

34.9

38.2

-32

.934

.137

.4-

32.1

33.3

36.5

-31

.332

.535

.6-

29.8

30.8

33.8

-27

.628

.631

.3-

S/T

0.72

0.60

0.42

-0.

740.

620.

43-

0.76

0.64

0.44

-0.

790.

660.

46-

0.82

0.68

0.47

-0.

820.

690.

48-

∆T19

1612

-19

1612

-19

1612

-19

1612

-19

1612

-17

1511

-

kW2.

252.

292.

36-

2.40

2.45

2.52

-2.

542.

592.

66-

2.65

2.71

2.79

-2.

752.

812.

89-

2.84

2.90

2.99

-

HI P

R22

223

925

3-

250

269

284

-28

430

632

3-

323

348

368

-36

439

241

3-

402

433

457

-LO

PR

110

117

127

-11

612

313

5-

120

128

140

-12

713

514

7-

133

141

154

-13

714

615

9-

1050

MBh

31.1

32.2

35.3

-30

.431

.534

.5-

29.6

30.7

33.7

-28

.930

.032

.8-

27.5

28.5

31.2

-25

.426

.428

.9-

S/T

0.69

0.58

0.40

-0.

720.

600.

42-

0.74

0.61

0.43

-0.

760.

630.

44-

0.79

0.66

0.46

-0.

800.

660.

46-

∆T19

1612

-19

1713

-19

1713

-19

1713

-19

1612

-18

1512

-

kW2.

202.

242.

30-

2.35

2.39

2.46

-2.

482.

532.

60-

2.60

2.65

2.72

-2.

692.

752.

83-

2.78

2.83

2.92

-

HI P

R21

623

224

5-

242

261

275

-27

529

631

3-

314

338

356

-35

338

040

1-

390

420

443

-LO

PR

106

113

124

-11

212

013

1-

117

124

136

-12

313

114

3-

129

137

149

-13

314

215

5-

75

1350

MBh

35.3

36.3

39.3

42.2

34.5

35.5

38.4

41.2

33.6

34.6

37.5

40.2

32.8

33.8

36.6

39.3

31.2

32.1

34.7

37.3

28.9

29.7

32.2

34.5

S/T

0.86

0.77

0.58

0.37

0.89

0.79

0.60

0.39

0.91

0.81

0.62

0.40

0.94

0.84

0.64

0.41

0.97

0.87

0.66

0.42

0.98

0.88

0.67

0.43

∆T21

1916

1121

1916

1121

1916

1121

1916

1121

1916

1119

1815

10

kW2.

282.

322.

392.

462.

442.

482.

552.

632.

572.

622.

702.

782.

692.

752.

832.

922.

802.

852.

943.

032.

892.

943.

033.

13

HI P

R22

724

425

826

925

527

428

930

229

031

232

934

333

035

537

539

137

139

942

244

041

044

146

648

6LO

PR

112

119

130

138

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

1200

MBh

34.2

35.3

38.2

41.0

33.5

34.4

37.3

40.0

32.7

33.6

36.4

39.1

31.9

32.8

35.5

38.1

30.3

31.2

33.7

36.2

28.0

28.9

31.2

33.5

S/T

0.82

0.73

0.55

0.36

0.85

0.76

0.57

0.37

0.87

0.78

0.59

0.38

0.90

0.80

0.61

0.39

0.93

0.83

0.63

0.40

0.94

0.84

0.63

0.41

∆T21

2016

1122

2016

1122

2016

1122

2016

1122

2016

1120

1915

10

kW2.

272.

312.

372.

442.

422.

472.

542.

612.

552.

602.

682.

762.

672.

732.

812.

892.

782.

832.

923.

012.

862.

923.

013.

10

HI P

R22

524

225

526

625

227

128

729

928

730

932

634

032

735

237

138

736

839

641

843

640

643

746

148

1LO

PR

111

118

129

137

117

125

136

145

122

129

141

151

128

136

149

158

134

143

156

166

139

147

161

171

1050

MBh

31.6

32.5

35.2

37.8

30.9

31.8

34.4

36.9

30.1

31.0

33.6

36.1

29.4

30.3

32.8

35.2

27.9

28.8

31.1

33.4

25.9

26.6

28.8

31.0

S/T

0.79

0.70

0.53

0.34

0.82

0.73

0.55

0.36

0.84

0.75

0.57

0.36

0.86

0.77

0.58

0.38

0.90

0.80

0.61

0.39

0.90

0.81

0.61

0.39

∆T22

2016

1122

2017

1122

2017

1222

2017

1222

2017

1120

1915

11

kW2.

222.

262.

322.

392.

372.

412.

482.

552.

502.

552.

622.

702.

612.

672.

742.

832.

712.

772.

852.

942.

802.

852.

943.

03

HI P

R21

823

524

825

824

526

327

829

027

829

931

633

031

734

136

037

635

738

440

542

339

442

444

846

7LO

PR

108

114

125

133

114

121

132

141

118

126

137

146

124

132

144

153

130

138

151

161

134

143

156

166

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Desig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

1350

MBh

35.9

36.7

39.2

41.9

35.1

35.8

38.3

40.9

34.2

35.0

37.4

40.0

33.4

34.1

36.5

39.0

31.7

32.4

34.6

37.0

29.4

30.0

32.1

34.3

S/T

0.94

0.88

0.72

0.5

1.00

0.91

0.74

0.6

1.00

0.94

0.76

0.6

1.00

0.97

0.79

0.6

1.00

1.00

0.82

0.6

1.00

1.00

0.82

0.6

∆T23

2219

1524

2219

1523

2219

1523

2220

1622

2219

1520

2018

14.4

kW2.

302.

342.

412.

52.

452.

502.

572.

62.

592.

642.

722.

82.

712.

772.

852.

92.

822.

882.

963.

12.

912.

973.

063.

2

HI P

R22

924

726

127

225

727

729

230

529

331

533

334

733

335

937

939

537

540

442

644

441

444

647

149

1LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

1200

MBh

34.9

35.6

38.1

40.7

34.0

34.8

37.2

39.7

33.2

34.0

36.3

38.8

32.4

33.1

35.4

37.8

30.8

31.5

33.6

36.0

28.5

29.2

31.2

33.3

S/T

0.90

0.84

0.68

0.5

0.93

0.87

0.71

0.5

0.95

0.89

0.73

0.5

0.98

0.92

0.75

0.6

1.00

0.96

0.78

0.6

1.00

0.96

0.78

0.6

∆T24

2320

1624

2320

1624

2320

1624

2320

1624

2320

1622

2219

15.0

kW2.

282.

322.

392.

52.

442.

482.

552.

62.

572.

622.

702.

82.

692.

752.

832.

92.

802.

852.

943.

02.

892.

943.

033.

1

HI P

R22

724

425

826

925

527

429

030

229

031

232

934

333

035

537

539

137

140

042

244

041

044

146

648

6LO

PR

112

119

130

139

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

1050

MBh

32.2

32.9

35.1

37.5

31.4

32.1

34.3

36.7

30.7

31.3

33.5

35.8

29.9

30.6

32.7

34.9

28.4

29.1

31.0

33.2

26.3

26.9

28.8

30.7

S/T

0.86

0.81

0.66

0.5

0.90

0.84

0.68

0.5

0.92

0.86

0.70

0.5

0.95

0.89

0.72

0.5

0.98

0.92

0.75

0.6

0.99

0.93

0.76

0.6

∆T24

2320

1625

2421

1625

2421

1625

2421

1724

2320

1623

2219

15.2

kW2.

232.

272.

342.

42.

382.

432.

502.

62.

522.

572.

642.

72.

632.

692.

772.

82.

732.

792.

873.

02.

822.

882.

963.

1

HI P

R22

023

725

026

124

726

628

129

328

130

231

933

332

034

436

437

936

038

840

942

739

842

845

247

2LO

PR

109

116

126

134

115

122

133

142

119

127

139

148

125

133

146

155

131

140

152

162

136

144

158

168

85

1350

MBh

36.5

37.2

39.0

41.6

35.7

36.4

38.1

40.6

34.8

35.5

37.2

39.7

34.0

34.6

36.3

38.7

32.3

32.9

34.5

36.8

29.9

30.5

31.9

34.1

S/T

0.98

0.95

0.86

0.7

1.00

0.98

0.89

0.7

1.00

1.00

0.91

0.7

1.00

1.00

0.94

0.8

1.00

1.00

0.98

0.8

1.00

1.00

0.98

0.8

∆T24

2423

2024

2423

2024

2423

2023

2423

2022

2223

2020

2121

18.5

kW2.

312.

362.

422.

52.

472.

522.

592.

72.

612.

662.

742.

82.

742.

792.

873.

02.

842.

902.

993.

12.

932.

993.

083.

2

HI P

R23

224

926

327

526

028

029

530

829

631

833

635

033

736

238

339

937

940

843

044

941

845

047

549

6LO

PR

114

122

133

141

121

128

140

149

125

133

146

155

132

140

153

163

138

147

160

171

143

152

166

177

1200

MBh

35.5

36.2

37.9

40.4

34.6

35.3

37.0

39.5

33.8

34.5

36.1

38.5

33.0

33.6

35.2

37.6

31.3

31.9

33.5

35.7

29.0

29.6

31.0

33.1

S/T

0.94

0.91

0.82

0.7

0.97

0.94

0.85

0.7

1.00

0.96

0.87

0.7

1.00

0.99

0.90

0.7

1.00

1.00

0.93

0.8

1.00

1.00

0.94

0.8

∆T26

2524

2126

2524

2126

2524

2125

2624

2124

2424

2122

2322

19.3

kW2.

302.

342.

412.

52.

452.

502.

572.

62.

592.

642.

722.

82.

712.

772.

852.

92.

822.

882.

963.

12.

912.

973.

063.

2

HI P

R22

924

726

127

225

727

729

230

529

331

533

334

733

335

937

939

537

540

442

644

441

444

647

149

1LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

1050

MBh

32.7

33.4

34.9

37.3

32.0

32.6

34.1

36.4

31.2

31.8

33.3

35.6

30.5

31.0

32.5

34.7

28.9

29.5

30.9

33.0

26.8

27.3

28.6

30.5

S/T

0.91

0.87

0.79

0.6

0.94

0.91

0.82

0.7

0.96

0.93

0.84

0.7

0.99

0.96

0.86

0.7

1.00

0.99

0.90

0.7

1.00

1.00

0.91

0.7

∆T26

2624

2126

2624

2126

2624

2126

2625

2125

2624

2123

2423

19.6

kW2.

252.

292.

352.

42.

402.

452.

522.

62.

542.

582.

662.

72.

652.

712.

792.

92.

752.

812.

893.

02.

842.

902.

993.

1

HI P

R22

223

925

326

425

026

928

429

628

430

532

333

632

334

836

738

336

439

141

343

140

243

245

747

6LO

PR

110

117

127

136

116

123

135

143

120

128

140

149

127

135

147

157

133

141

154

164

137

146

159

170

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 8: DTH Commercial

8 www.daikinac.com SS-DTH3

Expanded Cooling Data — 4 Tons (1-Phase Models)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

1800

MBh

45.6

47.2

51.7

-44

.546

.150

.5-

43.4

45.0

49.3

-42

.443

.948

.1-

40.3

41.7

45.7

-37

.338

.742

.4-

S/T

0.75

0.63

0.44

-0.

780.

650.

45-

0.80

0.67

0.46

-0.

830.

690.

48-

0.86

0.72

0.50

-0.

860.

720.

50-

∆T18

1512

-18

1512

-18

1512

-18

1512

-18

1512

-16

1411

-

kW3.

063.

123.

21-

3.28

3.35

3.45

-3.

483.

553.

66-

3.65

3.73

3.84

-3.

803.

884.

00-

3.92

4.01

4.14

-

HI P

R23

425

226

6-

262

282

298

-29

832

133

9-

340

366

386

-38

241

143

4-

422

454

480

-LO

PR

111

118

129

-11

712

513

6-

122

129

141

-12

813

614

8-

134

143

156

-13

914

716

1-

1600

MBh

44.2

45.9

50.2

-43

.244

.849

.1-

42.2

43.7

47.9

-41

.242

.746

.7-

39.1

40.5

44.4

-36

.237

.541

.1-

S/T

0.72

0.60

0.42

-0.

740.

620.

43-

0.76

0.64

0.44

-0.

790.

660.

46-

0.82

0.68

0.47

-0.

820.

690.

48-

∆T18

1612

-18

1612

-19

1612

-19

1612

-18

1612

-17

1511

-

kW3.

033.

093.

19-

3.25

3.32

3.42

-3.

453.

523.

63-

3.62

3.70

3.81

-3.

773.

853.

97-

3.89

3.98

4.10

-

HI P

R23

124

926

3-

260

279

295

-29

531

833

6-

336

362

382

-37

840

743

0-

418

450

475

-LO

PR

110

117

127

-11

612

313

5-

120

128

140

-12

713

514

7-

133

141

154

-13

714

615

9-

1400

MBh

40.8

42.3

46.4

-39

.941

.345

.3-

38.9

40.4

44.2

-38

.039

.443

.1-

36.1

37.4

41.0

-33

.434

.638

.0-

S/T

0.69

0.58

0.40

-0.

720.

600.

42-

0.74

0.61

0.43

-0.

760.

630.

44-

0.79

0.66

0.46

-0.

800.

660.

46-

∆T19

1612

-19

1612

-19

1612

-19

1612

-19

1612

-17

1511

-

kW2.

963.

023.

11-

3.18

3.24

3.34

-3.

373.

443.

54-

3.53

3.61

3.72

-3.

683.

753.

87-

3.80

3.88

4.00

-

HI P

R22

424

225

5-

252

271

286

-28

630

832

6-

326

351

371

-36

739

541

7-

406

436

461

-LO

PR

106

113

124

-11

212

013

1-

117

124

136

-12

313

114

3-

129

137

149

-13

314

215

5-

75

1800

MBh

46.3

47.7

51.6

55.4

45.3

46.6

50.4

54.1

44.2

45.5

49.2

52.8

43.1

44.4

48.0

51.6

41.0

42.2

45.6

49.0

37.9

39.1

42.3

45.4

S/T

0.86

0.77

0.58

0.37

0.89

0.79

0.60

0.39

0.91

0.81

0.62

0.40

0.94

0.84

0.64

0.41

0.97

0.87

0.66

0.42

0.98

0.88

0.67

0.43

∆T20

1915

1121

1915

1121

1915

1121

1916

1120

1915

1119

1814

10

kW3.

083.

143.

243.

333.

303.

373.

483.

583.

503.

583.

693.

803.

683.

763.

874.

003.

833.

914.

034.

163.

964.

044.

174.

31

HI P

R23

625

426

828

026

528

530

131

430

132

434

235

734

336

939

040

738

641

543

945

842

745

948

550

6LO

PR

112

119

130

138

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

1600

MBh

45.0

46.3

50.1

53.8

43.9

45.2

49.0

52.6

42.9

44.2

47.8

51.3

41.9

43.1

46.6

50.1

39.8

40.9

44.3

47.6

36.8

37.9

41.0

44.0

S/T

0.82

0.73

0.55

0.36

0.85

0.76

0.57

0.37

0.87

0.78

0.59

0.38

0.90

0.80

0.61

0.39

0.93

0.83

0.63

0.40

0.94

0.84

0.63

0.41

∆T21

1916

1121

2016

1121

2016

1122

2016

1121

2016

1120

1815

10

kW3.

063.

123.

213.

313.

283.

353.

453.

563.

483.

553.

663.

773.

653.

733.

843.

973.

803.

884.

004.

133.

924.

014.

144.

27

HI P

R23

425

226

627

726

228

229

831

129

832

133

935

434

036

638

640

338

241

143

445

342

245

448

050

1LO

PR

111

118

129

137

117

125

136

145

122

129

141

151

128

136

149

158

134

143

156

166

139

147

161

171

1400

MBh

41.5

42.8

46.3

49.7

40.6

41.8

45.2

48.5

39.6

40.8

44.1

47.4

38.6

39.8

43.0

46.2

36.7

37.8

40.9

43.9

34.0

35.0

37.9

40.7

S/T

0.79

0.70

0.53

0.34

0.82

0.73

0.55

0.36

0.84

0.75

0.57

0.36

0.86

0.77

0.58

0.38

0.90

0.80

0.61

0.39

0.90

0.81

0.61

0.39

∆T21

2016

1122

2016

1122

2016

1122

2017

1122

2016

1120

1915

11

kW2.

993.

053.

143.

233.

203.

273.

373.

473.

393.

463.

573.

683.

563.

643.

753.

873.

713.

783.

904.

033.

833.

914.

044.

17

HI P

R22

724

425

826

925

427

428

930

228

931

132

934

333

035

537

539

137

139

942

143

941

044

146

648

6LO

PR

108

114

125

133

114

121

132

141

118

126

137

146

124

132

144

153

130

138

151

161

134

143

156

166

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Desig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

1800

MBh

47.2

48.2

51.5

55.0

46.1

47.1

50.3

53.8

45.0

46.0

49.1

52.5

43.9

44.8

47.9

51.2

41.7

42.6

45.5

48.6

38.6

39.5

42.1

45.1

S/T

0.94

0.88

0.72

0.5

1.00

0.91

0.74

0.6

1.00

0.94

0.76

0.6

1.00

0.97

0.79

0.6

1.00

1.00

0.82

0.6

1.00

1.00

0.82

0.6

∆T23

2219

1524

2219

1523

2219

1522

2219

1521

2219

1520

2018

14.2

kW3.

103.

173.

263.

43.

333.

403.

503.

63.

533.

603.

723.

83.

713.

793.

914.

03.

863.

944.

074.

23.

994.

074.

214.

3

HI P

R23

825

727

128

326

828

830

431

730

432

834

636

134

737

339

441

139

042

044

346

243

146

449

051

1LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

1600

MBh

45.8

46.8

50.0

53.4

44.7

45.7

48.8

52.2

43.7

44.6

47.7

51.0

42.6

43.5

46.5

49.7

40.5

41.3

44.2

47.2

37.5

38.3

40.9

43.7

S/T

0.90

0.84

0.68

0.5

0.93

0.87

0.71

0.5

0.95

0.89

0.73

0.5

0.98

0.92

0.75

0.6

1.00

0.96

0.78

0.6

1.00

0.96

0.78

0.6

∆T24

2320

1624

2320

1624

2320

1624

2320

1623

2320

1622

2118

14.7

kW3.

083.

143.

243.

33.

303.

373.

483.

63.

503.

583.

693.

83.

683.

763.

884.

03.

833.

914.

034.

23.

964.

044.

174.

3

HI P

R23

625

426

828

026

528

530

131

430

132

434

235

734

336

939

040

738

641

543

945

842

745

948

550

6LO

PR

112

119

130

139

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

1400

MBh

42.3

43.2

46.1

49.3

41.3

42.2

45.1

48.2

40.3

41.2

44.0

47.0

39.3

40.2

42.9

45.9

37.3

38.2

40.8

43.6

34.6

35.4

37.8

40.4

S/T

0.86

0.81

0.66

0.5

0.90

0.84

0.68

0.5

0.92

0.86

0.70

0.5

0.95

0.89

0.72

0.5

0.98

0.92

0.75

0.6

0.99

0.93

0.76

0.6

∆T24

2320

1624

2320

1624

2320

1624

2320

1624

2320

1623

2219

15.0

kW3.

013.

073.

163.

33.

233.

293.

393.

53.

423.

493.

603.

73.

593.

673.

783.

93.

743.

813.

944.

13.

863.

944.

074.

2

HI P

R22

924

626

027

125

727

729

230

529

231

533

234

633

335

837

839

537

540

342

644

441

444

547

049

0LO

PR

109

116

126

134

115

122

133

142

119

127

139

148

125

133

146

155

131

140

152

162

136

144

158

168

85

1800

MBh

48.0

48.9

51.2

54.7

46.9

47.8

50.0

53.4

45.8

46.6

48.8

52.1

44.6

45.5

47.7

50.8

42.4

43.2

45.3

48.3

39.3

40.0

41.9

44.7

S/T

0.98

0.95

0.86

0.7

1.00

0.98

0.89

0.7

1.00

1.00

0.91

0.7

1.00

1.00

0.94

0.8

1.00

1.00

0.98

0.8

1.00

1.00

0.98

0.8

∆T24

2422

1924

2423

2023

2423

2023

2323

2022

2223

2020

2021

18.2

kW3.

133.

193.

293.

43.

363.

423.

533.

63.

563.

633.

753.

93.

743.

823.

944.

13.

893.

974.

104.

24.

024.

114.

244.

4

HI P

R24

125

927

428

527

029

130

732

030

733

134

936

435

037

739

841

539

442

444

846

743

546

849

551

6LO

PR

114

122

133

141

121

128

140

149

125

133

146

155

132

140

153

163

138

147

160

171

143

152

166

177

1600

MBh

46.6

47.5

49.7

53.1

45.5

46.4

48.6

51.8

44.4

45.3

47.4

50.6

43.3

44.2

46.3

49.4

41.2

42.0

44.0

46.9

38.1

38.9

40.7

43.4

S/T

0.94

0.91

0.82

0.7

0.97

0.94

0.85

0.7

1.00

0.96

0.87

0.7

1.00

0.99

0.90

0.7

1.00

1.00

0.93

0.8

1.00

1.00

0.94

0.8

∆T25

2523

2025

2524

2025

2524

2025

2524

2124

2424

2022

2222

19.0

kW3.

103.

173.

263.

43.

333.

403.

503.

63.

533.

603.

723.

83.

713.

793.

914.

03.

863.

944.

074.

23.

994.

074.

214.

3

HI P

R23

825

727

128

326

828

830

431

730

432

834

636

134

737

339

441

139

042

044

346

243

146

449

051

1LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

1400

MBh

43.0

43.8

45.9

49.0

42.0

42.8

44.8

47.8

41.0

41.8

43.8

46.7

40.0

40.8

42.7

45.6

38.0

38.7

40.6

43.3

35.2

35.9

37.6

40.1

S/T

0.91

0.87

0.79

0.6

0.94

0.91

0.82

0.7

0.96

0.93

0.84

0.7

0.99

0.96

0.86

0.7

1.00

0.99

0.90

0.7

1.00

1.00

0.91

0.7

∆T26

2524

2126

2524

2126

2524

2126

2624

2125

2524

2123

2422

19.3

kW3.

033.

093.

193.

33.

253.

323.

423.

53.

453.

523.

633.

73.

623.

703.

813.

93.

773.

853.

974.

13.

893.

974.

104.

2

HI P

R23

124

926

327

426

027

929

530

829

531

833

535

033

636

238

239

937

840

743

044

841

845

047

549

5LO

PR

110

117

127

136

116

123

135

143

120

128

140

149

127

135

147

157

133

141

154

164

137

146

159

170

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Desig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 9: DTH Commercial

SS-DTH3 www.daikinac.com 9

Expanded Cooling Data — 4 Tons (1-Phase Models) (cont.)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

1800

MBh

45.6

47.2

51.7

-44

.546

.150

.5-

43.4

45.0

49.3

-42

.443

.948

.1-

40.3

41.7

45.7

-37

.338

.742

.4-

S/T

0.75

0.63

0.44

-0.

780.

650.

45-

0.80

0.67

0.46

-0.

830.

690.

48-

0.86

0.72

0.50

-0.

860.

720.

50-

∆T18

1512

-18

1512

-18

1512

-18

1512

-18

1512

-16

1411

-

kW3.

063.

123.

21-

3.28

3.35

3.45

-3.

483.

553.

66-

3.65

3.73

3.84

-3.

803.

884.

00-

3.92

4.01

4.14

-

HI P

R23

425

226

6-

262

282

298

-29

832

133

9-

340

366

386

-38

241

143

4-

422

454

480

-LO

PR

111

118

129

-11

712

513

6-

122

129

141

-12

813

614

8-

134

143

156

-13

914

716

1-

1600

MBh

44.2

45.9

50.2

-43

.244

.849

.1-

42.2

43.7

47.9

-41

.242

.746

.7-

39.1

40.5

44.4

-36

.237

.541

.1-

S/T

0.72

0.60

0.42

-0.

740.

620.

43-

0.76

0.64

0.44

-0.

790.

660.

46-

0.82

0.68

0.47

-0.

820.

690.

48-

∆T18

1612

-18

1612

-19

1612

-19

1612

-18

1612

-17

1511

-

kW3.

033.

093.

19-

3.25

3.32

3.42

-3.

453.

523.

63-

3.62

3.70

3.81

-3.

773.

853.

97-

3.89

3.98

4.10

-

HI P

R23

124

926

3-

260

279

295

-29

531

833

6-

336

362

382

-37

840

743

0-

418

450

475

-LO

PR

110

117

127

-11

612

313

5-

120

128

140

-12

713

514

7-

133

141

154

-13

714

615

9-

1400

MBh

40.8

42.3

46.4

-39

.941

.345

.3-

38.9

40.4

44.2

-38

.039

.443

.1-

36.1

37.4

41.0

-33

.434

.638

.0-

S/T

0.69

0.58

0.40

-0.

720.

600.

42-

0.74

0.61

0.43

-0.

760.

630.

44-

0.79

0.66

0.46

-0.

800.

660.

46-

∆T19

1612

-19

1612

-19

1612

-19

1612

-19

1612

-17

1511

-

kW2.

963.

023.

11-

3.18

3.24

3.34

-3.

373.

443.

54-

3.53

3.61

3.72

-3.

683.

753.

87-

3.80

3.88

4.00

-

HI P

R22

424

225

5-

252

271

286

-28

630

832

6-

326

351

371

-36

739

541

7-

406

436

461

-LO

PR

106

113

124

-11

212

013

1-

117

124

136

-12

313

114

3-

129

137

149

-13

314

215

5-

75

1800

MBh

46.3

47.7

51.6

55.4

45.3

46.6

50.4

54.1

44.2

45.5

49.2

52.8

43.1

44.4

48.0

51.6

41.0

42.2

45.6

49.0

37.9

39.1

42.3

45.4

S/T

0.86

0.77

0.58

0.37

0.89

0.79

0.60

0.39

0.91

0.81

0.62

0.40

0.94

0.84

0.64

0.41

0.97

0.87

0.66

0.42

0.98

0.88

0.67

0.43

∆T20

1915

1121

1915

1121

1915

1121

1916

1120

1915

1119

1814

10

kW3.

083.

143.

243.

333.

303.

373.

483.

583.

503.

583.

693.

803.

683.

763.

874.

003.

833.

914.

034.

163.

964.

044.

174.

31

HI P

R23

625

426

828

026

528

530

131

430

132

434

235

734

336

939

040

738

641

543

945

842

745

948

550

6LO

PR

112

119

130

138

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

1600

MBh

45.0

46.3

50.1

53.8

43.9

45.2

49.0

52.6

42.9

44.2

47.8

51.3

41.9

43.1

46.6

50.1

39.8

40.9

44.3

47.6

36.8

37.9

41.0

44.0

S/T

0.82

0.73

0.55

0.36

0.85

0.76

0.57

0.37

0.87

0.78

0.59

0.38

0.90

0.80

0.61

0.39

0.93

0.83

0.63

0.40

0.94

0.84

0.63

0.41

∆T21

1916

1121

2016

1121

2016

1122

2016

1121

2016

1120

1815

10

kW3.

063.

123.

213.

313.

283.

353.

453.

563.

483.

553.

663.

773.

653.

733.

843.

973.

803.

884.

004.

133.

924.

014.

144.

27

HI P

R23

425

226

627

726

228

229

831

129

832

133

935

434

036

638

640

338

241

143

445

342

245

448

050

1LO

PR

111

118

129

137

117

125

136

145

122

129

141

151

128

136

149

158

134

143

156

166

139

147

161

171

1400

MBh

41.5

42.8

46.3

49.7

40.6

41.8

45.2

48.5

39.6

40.8

44.1

47.4

38.6

39.8

43.0

46.2

36.7

37.8

40.9

43.9

34.0

35.0

37.9

40.7

S/T

0.79

0.70

0.53

0.34

0.82

0.73

0.55

0.36

0.84

0.75

0.57

0.36

0.86

0.77

0.58

0.38

0.90

0.80

0.61

0.39

0.90

0.81

0.61

0.39

∆T21

2016

1122

2016

1122

2016

1122

2017

1122

2016

1120

1915

11

kW2.

993.

053.

143.

233.

203.

273.

373.

473.

393.

463.

573.

683.

563.

643.

753.

873.

713.

783.

904.

033.

833.

914.

044.

17

HI P

R22

724

425

826

925

427

428

930

228

931

132

934

333

035

537

539

137

139

942

143

941

044

146

648

6LO

PR

108

114

125

133

114

121

132

141

118

126

137

146

124

132

144

153

130

138

151

161

134

143

156

166

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Desig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

1800

MBh

47.2

48.2

51.5

55.0

46.1

47.1

50.3

53.8

45.0

46.0

49.1

52.5

43.9

44.8

47.9

51.2

41.7

42.6

45.5

48.6

38.6

39.5

42.1

45.1

S/T

0.94

0.88

0.72

0.5

1.00

0.91

0.74

0.6

1.00

0.94

0.76

0.6

1.00

0.97

0.79

0.6

1.00

1.00

0.82

0.6

1.00

1.00

0.82

0.6

∆T23

2219

1524

2219

1523

2219

1522

2219

1521

2219

1520

2018

14.2

kW3.

103.

173.

263.

43.

333.

403.

503.

63.

533.

603.

723.

83.

713.

793.

914.

03.

863.

944.

074.

23.

994.

074.

214.

3

HI P

R23

825

727

128

326

828

830

431

730

432

834

636

134

737

339

441

139

042

044

346

243

146

449

051

1LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

1600

MBh

45.8

46.8

50.0

53.4

44.7

45.7

48.8

52.2

43.7

44.6

47.7

51.0

42.6

43.5

46.5

49.7

40.5

41.3

44.2

47.2

37.5

38.3

40.9

43.7

S/T

0.90

0.84

0.68

0.5

0.93

0.87

0.71

0.5

0.95

0.89

0.73

0.5

0.98

0.92

0.75

0.6

1.00

0.96

0.78

0.6

1.00

0.96

0.78

0.6

∆T24

2320

1624

2320

1624

2320

1624

2320

1623

2320

1622

2118

14.7

kW3.

083.

143.

243.

33.

303.

373.

483.

63.

503.

583.

693.

83.

683.

763.

884.

03.

833.

914.

034.

23.

964.

044.

174.

3

HI P

R23

625

426

828

026

528

530

131

430

132

434

235

734

336

939

040

738

641

543

945

842

745

948

550

6LO

PR

112

119

130

139

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

1400

MBh

42.3

43.2

46.1

49.3

41.3

42.2

45.1

48.2

40.3

41.2

44.0

47.0

39.3

40.2

42.9

45.9

37.3

38.2

40.8

43.6

34.6

35.4

37.8

40.4

S/T

0.86

0.81

0.66

0.5

0.90

0.84

0.68

0.5

0.92

0.86

0.70

0.5

0.95

0.89

0.72

0.5

0.98

0.92

0.75

0.6

0.99

0.93

0.76

0.6

∆T24

2320

1624

2320

1624

2320

1624

2320

1624

2320

1623

2219

15.0

kW3.

013.

073.

163.

33.

233.

293.

393.

53.

423.

493.

603.

73.

593.

673.

783.

93.

743.

813.

944.

13.

863.

944.

074.

2

HI P

R22

924

626

027

125

727

729

230

529

231

533

234

633

335

837

839

537

540

342

644

441

444

547

049

0LO

PR

109

116

126

134

115

122

133

142

119

127

139

148

125

133

146

155

131

140

152

162

136

144

158

168

85

1800

MBh

48.0

48.9

51.2

54.7

46.9

47.8

50.0

53.4

45.8

46.6

48.8

52.1

44.6

45.5

47.7

50.8

42.4

43.2

45.3

48.3

39.3

40.0

41.9

44.7

S/T

0.98

0.95

0.86

0.7

1.00

0.98

0.89

0.7

1.00

1.00

0.91

0.7

1.00

1.00

0.94

0.8

1.00

1.00

0.98

0.8

1.00

1.00

0.98

0.8

∆T24

2422

1924

2423

2023

2423

2023

2323

2022

2223

2020

2021

18.2

kW3.

133.

193.

293.

43.

363.

423.

533.

63.

563.

633.

753.

93.

743.

823.

944.

13.

893.

974.

104.

24.

024.

114.

244.

4

HI P

R24

125

927

428

527

029

130

732

030

733

134

936

435

037

739

841

539

442

444

846

743

546

849

551

6LO

PR

114

122

133

141

121

128

140

149

125

133

146

155

132

140

153

163

138

147

160

171

143

152

166

177

1600

MBh

46.6

47.5

49.7

53.1

45.5

46.4

48.6

51.8

44.4

45.3

47.4

50.6

43.3

44.2

46.3

49.4

41.2

42.0

44.0

46.9

38.1

38.9

40.7

43.4

S/T

0.94

0.91

0.82

0.7

0.97

0.94

0.85

0.7

1.00

0.96

0.87

0.7

1.00

0.99

0.90

0.7

1.00

1.00

0.93

0.8

1.00

1.00

0.94

0.8

∆T25

2523

2025

2524

2025

2524

2025

2524

2124

2424

2022

2222

19.0

kW3.

103.

173.

263.

43.

333.

403.

503.

63.

533.

603.

723.

83.

713.

793.

914.

03.

863.

944.

074.

23.

994.

074.

214.

3

HI P

R23

825

727

128

326

828

830

431

730

432

834

636

134

737

339

441

139

042

044

346

243

146

449

051

1LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

1400

MBh

43.0

43.8

45.9

49.0

42.0

42.8

44.8

47.8

41.0

41.8

43.8

46.7

40.0

40.8

42.7

45.6

38.0

38.7

40.6

43.3

35.2

35.9

37.6

40.1

S/T

0.91

0.87

0.79

0.6

0.94

0.91

0.82

0.7

0.96

0.93

0.84

0.7

0.99

0.96

0.86

0.7

1.00

0.99

0.90

0.7

1.00

1.00

0.91

0.7

∆T26

2524

2126

2524

2126

2524

2126

2624

2125

2524

2123

2422

19.3

kW3.

033.

093.

193.

33.

253.

323.

423.

53.

453.

523.

633.

73.

623.

703.

813.

93.

773.

853.

974.

13.

893.

974.

104.

2

HI P

R23

124

926

327

426

027

929

530

829

531

833

535

033

636

238

239

937

840

743

044

841

845

047

549

5LO

PR

110

117

127

136

116

123

135

143

120

128

140

149

127

135

147

157

133

141

154

164

137

146

159

170

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Desig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 10: DTH Commercial

10 www.daikinac.com SS-DTH3

Expanded Cooling Data — 5 Tons (1-Phase Models)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

2300

MBh

58.3

60.4

66.2

-56

.959

.064

.7-

55.6

57.6

63.1

-54

.256

.261

.6-

51.5

53.4

58.5

-47

.749

.554

.2-

S/T

0.65

0.55

0.38

-0.

680.

570.

39-

0.69

0.58

0.40

-0.

720.

600.

41-

0.74

0.62

0.43

-0.

750.

630.

43-

∆T15

1310

-15

1310

-15

1310

-16

1310

-15

1310

-14

129

-

kW3.

944.

014.

13-

4.21

4.30

4.43

-4.

464.

554.

69-

4.68

4.77

4.92

-4.

864.

965.

12-

5.02

5.13

5.29

-

HI P

R24

626

427

9-

276

297

313

-31

433

735

6-

357

384

406

-40

243

245

7-

444

478

504

-LO

PR

111

118

129

-11

712

513

6-

122

129

141

-12

813

614

8-

134

143

156

-13

914

716

1-

2000

MBh

56.6

58.7

64.3

-55

.357

.362

.8-

54.0

55.9

61.3

-52

.754

.659

.8-

50.0

51.8

56.8

-46

.348

.052

.6-

S/T

0.62

0.52

0.36

-0.

650.

540.

37-

0.66

0.55

0.38

-0.

680.

570.

40-

0.71

0.59

0.41

-0.

710.

600.

41-

∆T16

1411

-16

1411

-16

1411

-17

1411

-16

1411

-15

1310

-

kW3.

913.

984.

10-

4.18

4.27

4.39

-4.

434.

524.

65-

4.64

4.74

4.88

-4.

824.

925.

08-

4.98

5.09

5.25

-

HI P

R24

326

227

6-

273

294

310

-31

033

435

3-

354

381

402

-39

842

845

2-

440

473

499

-LO

PR

110

117

127

-11

612

313

5-

120

128

140

-12

713

514

7-

133

141

154

-13

714

615

9-

1700

MBh

52.2

54.2

59.3

-51

.052

.958

.0-

49.8

51.6

56.6

-48

.650

.455

.2-

46.2

47.9

52.4

-42

.844

.348

.6-

S/T

0.60

0.50

0.35

-0.

620.

520.

36-

0.64

0.53

0.37

-0.

660.

550.

38-

0.68

0.57

0.40

-0.

690.

580.

40-

∆T17

1511

-17

1511

-17

1511

-17

1511

-17

1511

-16

1410

-

kW3.

823.

904.

01-

4.09

4.17

4.29

-4.

334.

414.

54-

4.53

4.63

4.77

-4.

714.

814.

96-

4.86

4.97

5.12

-

HI P

R23

625

426

8-

265

285

301

-30

132

434

2-

343

369

390

-38

641

543

8-

426

459

484

-LO

PR

106

113

124

-11

212

013

1-

117

124

136

-12

313

114

3-

129

137

149

-13

314

215

5-

75

2300

MBh

59.3

61.0

66.1

70.9

57.9

59.6

64.5

69.3

56.5

58.2

63.0

67.6

55.2

56.8

61.5

66.0

52.4

53.9

58.4

62.7

48.5

50.0

54.1

58.1

S/T

0.74

0.66

0.50

0.32

0.77

0.69

0.52

0.33

0.79

0.71

0.53

0.34

0.81

0.73

0.55

0.35

0.84

0.76

0.57

0.37

0.85

0.76

0.58

0.37

∆T18

1613

918

1613

918

1613

918

1714

918

1613

917

1512

9

kW3.

964.

044.

164.

284.

254.

334.

464.

604.

494.

594.

734.

874.

714.

814.

965.

124.

905.

005.

165.

325.

065.

175.

335.

50

HI P

R24

826

728

229

427

930

031

633

031

734

136

037

536

138

841

042

840

643

746

148

144

848

351

053

1LO

PR

112

119

130

138

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

2000

MBh

57.6

59.3

64.2

68.9

56.2

57.9

62.7

67.3

54.9

56.5

61.2

65.7

53.6

55.1

59.7

64.1

50.9

52.4

56.7

60.8

47.1

48.5

52.5

56.4

S/T

0.71

0.63

0.48

0.31

0.73

0.66

0.50

0.32

0.75

0.67

0.51

0.33

0.78

0.69

0.53

0.34

0.81

0.72

0.55

0.35

0.81

0.73

0.55

0.35

∆T19

1714

1019

1714

1019

1714

1019

1814

1019

1714

1018

1613

9

kW3.

944.

014.

134.

254.

214.

304.

434.

564.

464.

554.

694.

834.

684.

774.

925.

084.

864.

965.

125.

285.

025.

135.

295.

46

HI P

R24

626

427

929

127

629

731

332

731

433

735

637

235

738

440

642

340

243

245

747

644

447

850

552

6LO

PR

111

118

129

137

117

125

136

145

122

129

141

151

128

136

149

158

134

143

156

166

139

147

161

171

1700

MBh

53.1

54.7

59.2

63.6

51.9

53.4

57.8

62.1

50.7

52.2

56.5

60.6

49.4

50.9

55.1

59.1

47.0

48.3

52.3

56.2

43.5

44.8

48.5

52.0

S/T

0.68

0.61

0.46

0.30

0.71

0.63

0.48

0.31

0.73

0.65

0.49

0.32

0.75

0.67

0.51

0.33

0.78

0.69

0.53

0.34

0.78

0.70

0.53

0.34

∆T20

1815

1020

1815

1020

1815

1020

1815

1020

1815

1018

1714

10

kW3.

853.

924.

044.

164.

124.

204.

334.

464.

364.

454.

584.

724.

574.

664.

814.

954.

754.

855.

005.

154.

905.

015.

165.

32

HI P

R23

825

727

128

326

728

830

431

730

432

734

636

134

637

339

441

139

041

944

346

243

146

348

951

0LO

PR

108

114

125

133

114

121

132

141

118

126

137

146

124

132

144

153

130

138

151

161

134

143

156

166

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Out

door

Am

bien

t Tem

pera

ture

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Airfl

ow59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

2300

MBh

60.3

61.7

65.9

70.4

58.9

60.2

64.3

68.8

57.5

58.8

62.8

67.2

56.1

57.4

61.3

65.5

53.3

54.5

58.2

62.2

49.4

50.5

53.9

57.7

S/T

0.81

0.76

0.62

0.5

0.84

0.79

0.64

0.5

0.86

0.81

0.66

0.5

0.89

0.84

0.68

0.5

0.93

0.87

0.71

0.5

0.93

0.88

0.71

0.5

∆T20

1916

1320

1917

1320

1917

1320

1917

1320

1916

1318

1815

12.3

kW3.

994.

074.

194.

34.

284.

364.

494.

64.

534.

624.

764.

94.

754.

855.

005.

24.

945.

045.

205.

45.

105.

215.

375.

5

HI P

R25

127

028

529

728

130

332

033

332

034

436

437

936

439

241

443

241

044

146

648

645

348

751

553

7LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

2000

MBh

58.6

59.9

64.0

68.4

57.2

58.5

62.5

66.8

55.9

57.1

61.0

65.2

54.5

55.7

59.5

63.6

51.8

52.9

56.5

60.4

48.0

49.0

52.4

56.0

S/T

0.78

0.73

0.59

0.4

0.80

0.75

0.61

0.5

0.82

0.77

0.63

0.5

0.85

0.80

0.65

0.5

0.88

0.83

0.67

0.5

0.89

0.84

0.68

0.5

∆T21

2017

1421

2018

1421

2018

1421

2018

1421

2018

1420

1916

13.1

kW3.

974.

044.

164.

34.

254.

334.

464.

64.

504.

594.

734.

94.

714.

814.

965.

14.

905.

005.

165.

35.

065.

175.

335.

5

HI P

R24

826

728

229

427

930

031

733

031

734

136

037

536

138

841

042

840

643

746

148

144

848

351

053

2LO

PR

112

119

130

139

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

1700

MBh

54.1

55.3

59.0

63.1

52.8

54.0

57.7

61.6

51.6

52.7

56.3

60.2

50.3

51.4

54.9

58.7

47.8

48.8

52.2

55.8

44.3

45.2

48.3

51.7

S/T

0.75

0.70

0.57

0.4

0.78

0.73

0.59

0.4

0.80

0.75

0.61

0.5

0.82

0.77

0.63

0.5

0.85

0.80

0.65

0.5

0.86

0.81

0.66

0.5

∆T22

2118

1522

2118

1522

2118

1522

2119

1522

2118

1521

2017

13.7

kW3.

883.

954.

074.

24.

154.

234.

364.

54.

394.

484.

624.

84.

604.

704.

845.

04.

794.

885.

045.

24.

945.

045.

205.

4

HI P

R24

125

927

428

527

029

130

732

030

733

134

936

435

037

739

841

539

442

444

746

743

546

849

451

6LO

PR

109

116

126

134

115

122

133

142

119

127

139

148

125

133

146

155

131

140

152

162

136

144

158

168

85

2300

MBh

61.4

62.6

65.6

69.9

60.0

61.1

64.0

68.3

58.5

59.7

62.5

66.7

57.1

58.2

61.0

65.1

54.3

55.3

57.9

61.8

50.3

51.2

53.7

57.2

S/T

0.85

0.82

0.74

0.6

0.88

0.85

0.77

0.6

0.91

0.88

0.79

0.6

0.94

0.90

0.82

0.7

0.97

0.94

0.85

0.7

0.98

0.95

0.85

0.7

∆T21

2119

1721

2120

1721

2120

1721

2120

1721

2120

1720

1918

15.8

kW4.

024.

104.

224.

34.

314.

404.

534.

74.

564.

664.

804.

94.

794.

895.

045.

24.

985.

085.

245.

45.

145.

255.

425.

6

HI P

R25

327

228

830

028

430

632

333

732

334

836

738

336

839

641

843

641

444

647

149

145

749

252

054

2LO

PR

114

122

133

141

121

128

140

149

125

133

146

155

132

140

153

163

138

147

160

171

143

152

166

177

2000

MBh

59.6

60.8

63.6

67.9

58.2

59.4

62.2

66.3

56.8

57.9

60.7

64.7

55.5

56.5

59.2

63.2

52.7

53.7

56.2

60.0

48.8

49.7

52.1

55.6

S/T

0.81

0.79

0.71

0.6

0.84

0.81

0.73

0.6

0.86

0.83

0.75

0.6

0.89

0.86

0.78

0.6

0.93

0.89

0.81

0.7

0.93

0.90

0.81

0.7

∆T22

2221

1823

2221

1823

2221

1823

2221

1822

2221

1821

2119

16.9

kW3.

994.

074.

194.

34.

284.

364.

494.

64.

534.

624.

764.

94.

754.

855.

005.

24.

945.

045.

205.

45.

105.

215.

375.

5

HI P

R25

127

028

529

728

130

332

033

332

034

436

437

936

439

241

443

241

044

146

648

645

348

751

553

7LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

1700

MBh

55.0

56.1

58.7

62.7

53.7

54.8

57.4

61.2

52.5

53.5

56.0

59.8

51.2

52.2

54.6

58.3

48.6

49.6

51.9

55.4

45.0

45.9

48.1

51.3

S/T

0.78

0.76

0.68

0.6

0.81

0.78

0.71

0.6

0.83

0.80

0.73

0.6

0.86

0.83

0.75

0.6

0.89

0.86

0.78

0.6

0.90

0.87

0.78

0.6

∆T23

2322

1924

2322

1924

2322

1924

2322

1923

2322

1922

2220

17.7

kW3.

913.

984.

104.

24.

184.

274.

394.

54.

434.

524.

654.

84.

644.

744.

885.

04.

824.

925.

085.

24.

985.

085.

245.

4

HI P

R24

326

227

628

827

329

431

032

331

033

435

336

835

338

040

241

939

842

845

247

143

947

349

952

1LO

PR

110

117

127

136

116

123

135

143

120

128

140

149

127

135

147

157

133

141

154

164

137

146

159

170

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 11: DTH Commercial

SS-DTH3 www.daikinac.com 11

Expanded Cooling Data — 5 Tons (1-Phase Models) (cont.)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

2300

MBh

58.3

60.4

66.2

-56

.959

.064

.7-

55.6

57.6

63.1

-54

.256

.261

.6-

51.5

53.4

58.5

-47

.749

.554

.2-

S/T

0.65

0.55

0.38

-0.

680.

570.

39-

0.69

0.58

0.40

-0.

720.

600.

41-

0.74

0.62

0.43

-0.

750.

630.

43-

∆T15

1310

-15

1310

-15

1310

-16

1310

-15

1310

-14

129

-

kW3.

944.

014.

13-

4.21

4.30

4.43

-4.

464.

554.

69-

4.68

4.77

4.92

-4.

864.

965.

12-

5.02

5.13

5.29

-

HI P

R24

626

427

9-

276

297

313

-31

433

735

6-

357

384

406

-40

243

245

7-

444

478

504

-LO

PR

111

118

129

-11

712

513

6-

122

129

141

-12

813

614

8-

134

143

156

-13

914

716

1-

2000

MBh

56.6

58.7

64.3

-55

.357

.362

.8-

54.0

55.9

61.3

-52

.754

.659

.8-

50.0

51.8

56.8

-46

.348

.052

.6-

S/T

0.62

0.52

0.36

-0.

650.

540.

37-

0.66

0.55

0.38

-0.

680.

570.

40-

0.71

0.59

0.41

-0.

710.

600.

41-

∆T16

1411

-16

1411

-16

1411

-17

1411

-16

1411

-15

1310

-

kW3.

913.

984.

10-

4.18

4.27

4.39

-4.

434.

524.

65-

4.64

4.74

4.88

-4.

824.

925.

08-

4.98

5.09

5.25

-

HI P

R24

326

227

6-

273

294

310

-31

033

435

3-

354

381

402

-39

842

845

2-

440

473

499

-LO

PR

110

117

127

-11

612

313

5-

120

128

140

-12

713

514

7-

133

141

154

-13

714

615

9-

1700

MBh

52.2

54.2

59.3

-51

.052

.958

.0-

49.8

51.6

56.6

-48

.650

.455

.2-

46.2

47.9

52.4

-42

.844

.348

.6-

S/T

0.60

0.50

0.35

-0.

620.

520.

36-

0.64

0.53

0.37

-0.

660.

550.

38-

0.68

0.57

0.40

-0.

690.

580.

40-

∆T17

1511

-17

1511

-17

1511

-17

1511

-17

1511

-16

1410

-

kW3.

823.

904.

01-

4.09

4.17

4.29

-4.

334.

414.

54-

4.53

4.63

4.77

-4.

714.

814.

96-

4.86

4.97

5.12

-

HI P

R23

625

426

8-

265

285

301

-30

132

434

2-

343

369

390

-38

641

543

8-

426

459

484

-LO

PR

106

113

124

-11

212

013

1-

117

124

136

-12

313

114

3-

129

137

149

-13

314

215

5-

75

2300

MBh

59.3

61.0

66.1

70.9

57.9

59.6

64.5

69.3

56.5

58.2

63.0

67.6

55.2

56.8

61.5

66.0

52.4

53.9

58.4

62.7

48.5

50.0

54.1

58.1

S/T

0.74

0.66

0.50

0.32

0.77

0.69

0.52

0.33

0.79

0.71

0.53

0.34

0.81

0.73

0.55

0.35

0.84

0.76

0.57

0.37

0.85

0.76

0.58

0.37

∆T18

1613

918

1613

918

1613

918

1714

918

1613

917

1512

9

kW3.

964.

044.

164.

284.

254.

334.

464.

604.

494.

594.

734.

874.

714.

814.

965.

124.

905.

005.

165.

325.

065.

175.

335.

50

HI P

R24

826

728

229

427

930

031

633

031

734

136

037

536

138

841

042

840

643

746

148

144

848

351

053

1LO

PR

112

119

130

138

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

2000

MBh

57.6

59.3

64.2

68.9

56.2

57.9

62.7

67.3

54.9

56.5

61.2

65.7

53.6

55.1

59.7

64.1

50.9

52.4

56.7

60.8

47.1

48.5

52.5

56.4

S/T

0.71

0.63

0.48

0.31

0.73

0.66

0.50

0.32

0.75

0.67

0.51

0.33

0.78

0.69

0.53

0.34

0.81

0.72

0.55

0.35

0.81

0.73

0.55

0.35

∆T19

1714

1019

1714

1019

1714

1019

1814

1019

1714

1018

1613

9

kW3.

944.

014.

134.

254.

214.

304.

434.

564.

464.

554.

694.

834.

684.

774.

925.

084.

864.

965.

125.

285.

025.

135.

295.

46

HI P

R24

626

427

929

127

629

731

332

731

433

735

637

235

738

440

642

340

243

245

747

644

447

850

552

6LO

PR

111

118

129

137

117

125

136

145

122

129

141

151

128

136

149

158

134

143

156

166

139

147

161

171

1700

MBh

53.1

54.7

59.2

63.6

51.9

53.4

57.8

62.1

50.7

52.2

56.5

60.6

49.4

50.9

55.1

59.1

47.0

48.3

52.3

56.2

43.5

44.8

48.5

52.0

S/T

0.68

0.61

0.46

0.30

0.71

0.63

0.48

0.31

0.73

0.65

0.49

0.32

0.75

0.67

0.51

0.33

0.78

0.69

0.53

0.34

0.78

0.70

0.53

0.34

∆T20

1815

1020

1815

1020

1815

1020

1815

1020

1815

1018

1714

10

kW3.

853.

924.

044.

164.

124.

204.

334.

464.

364.

454.

584.

724.

574.

664.

814.

954.

754.

855.

005.

154.

905.

015.

165.

32

HI P

R23

825

727

128

326

728

830

431

730

432

734

636

134

637

339

441

139

041

944

346

243

146

348

951

0LO

PR

108

114

125

133

114

121

132

141

118

126

137

146

124

132

144

153

130

138

151

161

134

143

156

166

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Out

door

Am

bien

t Tem

pera

ture

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Airfl

ow59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

2300

MBh

60.3

61.7

65.9

70.4

58.9

60.2

64.3

68.8

57.5

58.8

62.8

67.2

56.1

57.4

61.3

65.5

53.3

54.5

58.2

62.2

49.4

50.5

53.9

57.7

S/T

0.81

0.76

0.62

0.5

0.84

0.79

0.64

0.5

0.86

0.81

0.66

0.5

0.89

0.84

0.68

0.5

0.93

0.87

0.71

0.5

0.93

0.88

0.71

0.5

∆T20

1916

1320

1917

1320

1917

1320

1917

1320

1916

1318

1815

12.3

kW3.

994.

074.

194.

34.

284.

364.

494.

64.

534.

624.

764.

94.

754.

855.

005.

24.

945.

045.

205.

45.

105.

215.

375.

5

HI P

R25

127

028

529

728

130

332

033

332

034

436

437

936

439

241

443

241

044

146

648

645

348

751

553

7LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

2000

MBh

58.6

59.9

64.0

68.4

57.2

58.5

62.5

66.8

55.9

57.1

61.0

65.2

54.5

55.7

59.5

63.6

51.8

52.9

56.5

60.4

48.0

49.0

52.4

56.0

S/T

0.78

0.73

0.59

0.4

0.80

0.75

0.61

0.5

0.82

0.77

0.63

0.5

0.85

0.80

0.65

0.5

0.88

0.83

0.67

0.5

0.89

0.84

0.68

0.5

∆T21

2017

1421

2018

1421

2018

1421

2018

1421

2018

1420

1916

13.1

kW3.

974.

044.

164.

34.

254.

334.

464.

64.

504.

594.

734.

94.

714.

814.

965.

14.

905.

005.

165.

35.

065.

175.

335.

5

HI P

R24

826

728

229

427

930

031

733

031

734

136

037

536

138

841

042

840

643

746

148

144

848

351

053

2LO

PR

112

119

130

139

118

126

137

146

123

131

143

152

129

137

150

160

135

144

157

167

140

149

163

173

1700

MBh

54.1

55.3

59.0

63.1

52.8

54.0

57.7

61.6

51.6

52.7

56.3

60.2

50.3

51.4

54.9

58.7

47.8

48.8

52.2

55.8

44.3

45.2

48.3

51.7

S/T

0.75

0.70

0.57

0.4

0.78

0.73

0.59

0.4

0.80

0.75

0.61

0.5

0.82

0.77

0.63

0.5

0.85

0.80

0.65

0.5

0.86

0.81

0.66

0.5

∆T22

2118

1522

2118

1522

2118

1522

2119

1522

2118

1521

2017

13.7

kW3.

883.

954.

074.

24.

154.

234.

364.

54.

394.

484.

624.

84.

604.

704.

845.

04.

794.

885.

045.

24.

945.

045.

205.

4

HI P

R24

125

927

428

527

029

130

732

030

733

134

936

435

037

739

841

539

442

444

746

743

546

849

451

6LO

PR

109

116

126

134

115

122

133

142

119

127

139

148

125

133

146

155

131

140

152

162

136

144

158

168

85

2300

MBh

61.4

62.6

65.6

69.9

60.0

61.1

64.0

68.3

58.5

59.7

62.5

66.7

57.1

58.2

61.0

65.1

54.3

55.3

57.9

61.8

50.3

51.2

53.7

57.2

S/T

0.85

0.82

0.74

0.6

0.88

0.85

0.77

0.6

0.91

0.88

0.79

0.6

0.94

0.90

0.82

0.7

0.97

0.94

0.85

0.7

0.98

0.95

0.85

0.7

∆T21

2119

1721

2120

1721

2120

1721

2120

1721

2120

1720

1918

15.8

kW4.

024.

104.

224.

34.

314.

404.

534.

74.

564.

664.

804.

94.

794.

895.

045.

24.

985.

085.

245.

45.

145.

255.

425.

6

HI P

R25

327

228

830

028

430

632

333

732

334

836

738

336

839

641

843

641

444

647

149

145

749

252

054

2LO

PR

114

122

133

141

121

128

140

149

125

133

146

155

132

140

153

163

138

147

160

171

143

152

166

177

2000

MBh

59.6

60.8

63.6

67.9

58.2

59.4

62.2

66.3

56.8

57.9

60.7

64.7

55.5

56.5

59.2

63.2

52.7

53.7

56.2

60.0

48.8

49.7

52.1

55.6

S/T

0.81

0.79

0.71

0.6

0.84

0.81

0.73

0.6

0.86

0.83

0.75

0.6

0.89

0.86

0.78

0.6

0.93

0.89

0.81

0.7

0.93

0.90

0.81

0.7

∆T22

2221

1823

2221

1823

2221

1823

2221

1822

2221

1821

2119

16.9

kW3.

994.

074.

194.

34.

284.

364.

494.

64.

534.

624.

764.

94.

754.

855.

005.

24.

945.

045.

205.

45.

105.

215.

375.

5

HI P

R25

127

028

529

728

130

332

033

332

034

436

437

936

439

241

443

241

044

146

648

645

348

751

553

7LO

PR

113

120

131

140

119

127

139

148

124

132

144

154

130

139

152

161

137

145

159

169

141

150

164

175

1700

MBh

55.0

56.1

58.7

62.7

53.7

54.8

57.4

61.2

52.5

53.5

56.0

59.8

51.2

52.2

54.6

58.3

48.6

49.6

51.9

55.4

45.0

45.9

48.1

51.3

S/T

0.78

0.76

0.68

0.6

0.81

0.78

0.71

0.6

0.83

0.80

0.73

0.6

0.86

0.83

0.75

0.6

0.89

0.86

0.78

0.6

0.90

0.87

0.78

0.6

∆T23

2322

1924

2322

1924

2322

1924

2322

1923

2322

1922

2220

17.7

kW3.

913.

984.

104.

24.

184.

274.

394.

54.

434.

524.

654.

84.

644.

744.

885.

04.

824.

925.

085.

24.

985.

085.

245.

4

HI P

R24

326

227

628

827

329

431

032

331

033

435

336

835

338

040

241

939

842

845

247

143

947

349

952

1LO

PR

110

117

127

136

116

123

135

143

120

128

140

149

127

135

147

157

133

141

154

164

137

146

159

170

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 12: DTH Commercial

12 www.daikinac.com SS-DTH3

Expanded Cooling Data — 3 Tons (3-Phase Models)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

1347

MBh

34.3

35.6

39.0

-33

.534

.738

.0-

32.7

33.9

37.1

-31

.933

.136

.2-

30.3

31.4

34.4

-28

.129

.131

.9-

S/T

0.81

0.67

0.47

-0.

830.

700.

48-

0.86

0.71

0.50

-0.

880.

740.

51-

0.92

0.77

0.53

-0.

920.

770.

53-

Del

ta T

1916

12-

1917

13-

1917

13-

1917

13-

1916

12-

1815

12-

KW2.

092.

132.

19-

2.24

2.29

2.36

-2.

382.

432.

50-

2.49

2.55

2.63

-2.

602.

652.

74-

2.68

2.74

2.83

-AM

PS7.

67.

77.

9-

8.1

8.2

8.4

-8.

68.

89.

0-

9.1

9.3

9.5

-9.

69.

810

.0-

10.0

10.2

10.5

-H

I PR

219

235

249

-24

526

427

9-

279

300

317

-31

834

236

1-

358

385

406

-39

542

544

9-

LO P

R11

712

413

6-

123

131

143

-12

813

614

9-

135

143

156

-14

115

016

4-

146

155

170

-

1200

MBh

33.3

34.5

37.8

-32

.533

.736

.9-

31.8

32.9

36.1

-31

.032

.135

.2-

29.4

30.5

33.4

-27

.328

.331

.0-

S/T

0.77

0.64

0.44

-0.

800.

660.

46-

0.82

0.68

0.47

-0.

840.

700.

49-

0.87

0.73

0.51

-0.

880.

740.

51-

Del

ta T

2017

13-

2017

13-

2017

13-

2017

13-

2017

13-

1816

12-

KW2.

072.

112.

18-

2.22

2.27

2.34

-2.

362.

412.

48-

2.48

2.53

2.61

-2.

582.

632.

71-

2.66

2.72

2.81

-AM

PS7.

57.

77.

9-

8.0

8.2

8.4

-8.

58.

78.

9-

9.0

9.2

9.5

-9.

59.

710

.0-

10.0

10.2

10.5

-H

I PR

217

233

246

-24

326

227

6-

276

297

314

-31

533

935

8-

354

381

402

-39

142

144

5-

LO P

R11

612

313

4-

122

130

142

-12

713

514

7-

133

142

155

-14

014

916

2-

145

154

168

-

1062

MBh

31.6

32.8

35.9

-30

.932

.035

.1-

30.2

31.3

34.3

-29

.430

.533

.4-

28.0

29.0

31.7

-25

.926

.829

.4-

S/T

0.74

0.61

0.43

-0.

760.

640.

44-

0.78

0.65

0.45

-0.

810.

670.

47-

0.84

0.70

0.48

-0.

840.

710.

49-

Del

ta T

2017

13-

2018

13-

2018

13-

2118

14-

2018

13-

1916

12-

KW2.

042.

082.

14-

2.19

2.23

2.30

-2.

322.

372.

44-

2.44

2.49

2.57

-2.

532.

592.

67-

2.62

2.67

2.76

-AM

PS7.

47.

67.

7-

7.9

8.0

8.2

-8.

48.

68.

8-

8.9

9.1

9.3

-9.

39.

59.

8-

9.8

10.0

10.3

-H

I PR

212

228

241

-23

825

627

1-

271

291

308

-30

833

235

1-

347

373

394

-38

341

343

6-

LO P

R11

312

113

2-

120

127

139

-12

413

214

4-

131

139

152

-13

714

615

9-

142

151

164

-

75

1347

MBh

34.9

35.9

38.9

41.7

34.1

35.1

38.0

40.8

33.3

34.2

37.1

39.8

32.4

33.4

36.2

38.8

30.8

31.7

34.4

36.9

28.6

29.4

31.8

34.2

S/T

0.92

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.97

0.87

0.66

0.42

1.00

0.90

0.68

0.44

1.00

0.93

0.71

0.45

1.00

0.94

0.71

0.46

Del

ta T

2220

1611

2220

1711

2220

1712

2220

1712

2120

1711

1919

1511

KW2.

102.

152.

212.

282.

262.

312.

382.

452.

402.

452.

522.

602.

522.

572.

652.

742.

622.

672.

762.

852.

712.

762.

852.

95AM

PS7.

67.

88.

08.

28.

18.

38.

58.

78.

78.

89.

19.

49.

29.

39.

69.

99.

69.

810

.110

.410

.110

.310

.611

.0H

I PR

221

238

251

262

248

267

282

294

282

303

320

334

321

346

365

381

361

389

411

428

399

430

454

473

LO P

R11

812

513

714

612

513

314

515

412

913

815

016

013

614

515

816

814

315

216

617

614

715

717

118

2

1200

MBh

33.9

34.9

37.7

40.5

33.1

34.1

36.9

39.6

32.3

33.2

36.0

38.6

31.5

32.4

35.1

37.7

29.9

30.8

33.4

35.8

27.7

28.5

30.9

33.2

S/T

0.87

0.78

0.59

0.38

0.90

0.81

0.61

0.39

0.93

0.83

0.63

0.40

0.96

0.86

0.65

0.42

0.99

0.89

0.67

0.43

1.00

0.90

0.68

0.44

Del

ta T

2321

1712

2321

1712

2321

1712

2321

1712

2321

1712

2120

1611

KW2.

092.

132.

192.

262.

242.

292.

362.

432.

382.

432.

502.

582.

502.

552.

632.

712.

602.

652.

742.

832.

682.

742.

832.

92AM

PS7.

67.

77.

98.

28.

18.

28.

48.

78.

68.

89.

09.

39.

19.

39.

59.

89.

69.

810

.010

.410

.010

.210

.510

.9H

I PR

219

235

249

259

245

264

279

291

279

300

317

331

318

342

361

377

358

385

407

424

395

425

449

468

LO P

R11

712

413

614

412

313

114

315

312

813

614

915

913

514

315

616

714

115

016

417

514

615

517

018

1

1062

MBh

32.2

33.1

35.9

38.5

31.4

32.4

35.0

37.6

30.7

31.6

34.2

36.7

29.9

30.8

33.4

35.8

28.4

29.3

31.7

34.0

26.3

27.1

29.4

31.5

S/T

0.84

0.75

0.57

0.36

0.87

0.78

0.59

0.38

0.89

0.79

0.60

0.39

0.92

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.96

0.86

0.65

0.42

Del

ta T

2321

1812

2422

1812

2422

1812

2422

1812

2322

1812

2220

1711

KW2.

062.

102.

162.

232.

212.

252.

322.

392.

342.

392.

462.

542.

462.

512.

592.

672.

552.

612.

692.

782.

642.

702.

782.

87AM

PS7.

57.

67.

88.

07.

98.

18.

38.

68.

58.

68.

99.

29.

09.

19.

49.

79.

49.

69.

910

.29.

910

.110

.410

.7H

I PR

214

231

244

254

241

259

273

285

274

294

311

324

312

335

354

369

351

377

398

416

387

417

440

459

LO P

R11

412

213

314

212

112

914

015

012

613

414

615

513

214

015

316

313

814

716

117

114

315

216

617

7ID

B =

Ente

ring

Indo

or D

ry B

ulb

Tem

pera

ture

Shad

ed a

rea

refle

cts

ACCA

(TVA

) con

ditio

nskW

= T

otal

sys

tem

pow

erH

igh

& lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d &

suc

tion

serv

ice

port

s.Am

ps: U

nit a

mps

(com

p.+

evap

orat

or +

con

dens

er fa

n m

otor

s)D

esig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

±3 °F

@ th

e co

mpr

esso

r suc

tion

acce

ss fi

tting

con

necti

on.

Out

door

Am

bien

t Tem

pera

ture

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Airfl

ow59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

1347

MBh

35.5

36.3

38.8

41.4

34.7

35.4

37.9

40.5

33.9

34.6

37.0

39.5

33.0

33.7

36.1

38.5

31.4

32.1

34.3

36.6

29.1

29.7

31.7

33.9

S/T

1.00

0.94

0.77

0.57

1.00

1.00

0.79

0.59

1.00

1.00

0.81

0.61

1.00

1.00

0.84

0.63

1.00

1.00

0.87

0.65

1.00

1.00

0.88

0.66

Del

ta T

2423

2016

2424

2116

2324

2116

2323

2117

2122

2016

2020

1915

KW2.

122.

162.

232.

302.

282.

322.

402.

472.

412.

462.

542.

622.

542.

592.

672.

762.

642.

702.

782.

872.

732.

792.

882.

97AM

PS7.

77.

88.

08.

38.

28.

38.

68.

88.

78.

99.

29.

49.

29.

49.

710

.09.

79.

910

.210

.510

.210

.410

.711

.1H

I PR

223

240

254

265

250

270

285

297

285

307

324

338

324

349

369

385

365

393

415

433

403

434

458

478

LO P

R11

912

713

814

712

613

414

615

613

113

915

216

213

714

616

017

014

415

316

717

814

915

817

318

4

1200

MBh

34.5

35.2

37.6

40.2

33.7

34.4

36.8

39.3

32.9

33.6

35.9

38.4

32.1

32.8

35.0

37.4

30.5

31.1

33.3

35.5

28.2

28.8

30.8

32.9

S/T

0.96

0.90

0.73

0.55

0.99

0.93

0.76

0.57

1.00

0.95

0.78

0.58

1.00

0.98

0.80

0.60

1.00

1.00

0.83

0.62

1.00

1.00

0.84

0.63

Del

ta T

2524

2117

2625

2117

2525

2117

2525

2217

2324

2117

2222

2016

KW2.

102.

152.

212.

282.

262.

312.

382.

452.

402.

452.

522.

602.

522.

572.

652.

742.

622.

672.

762.

852.

712.

762.

852.

95AM

PS7.

67.

88.

08.

28.

18.

38.

58.

78.

78.

89.

19.

49.

29.

39.

69.

99.

69.

810

.110

.410

.110

.310

.611

.0H

I PR

221

238

251

262

248

267

282

294

282

303

320

334

321

346

365

381

361

389

411

428

399

430

454

473

LO P

R11

812

513

714

612

513

314

515

413

013

815

016

013

614

515

816

814

315

216

617

614

715

717

118

2

1062

MBh

32.7

33.5

35.7

38.2

32.0

32.7

34.9

37.3

31.2

31.9

34.1

36.4

30.5

31.1

33.3

35.5

28.9

29.6

31.6

33.8

26.8

27.4

29.3

31.3

S/T

0.92

0.86

0.70

0.52

0.95

0.89

0.73

0.54

0.97

0.91

0.74

0.56

1.01

0.94

0.77

0.57

1.04

0.98

0.80

0.60

1.00

0.99

0.80

0.60

Del

ta T

2625

2217

2625

2218

2625

2218

2725

2218

2625

2217

2323

2016

KW2.

072.

112.

182.

242.

222.

272.

342.

412.

362.

412.

482.

562.

482.

532.

612.

692.

582.

632.

712.

802.

662.

722.

812.

90AM

PS7.

57.

77.

98.

18.

08.

28.

48.

68.

58.

78.

99.

29.

09.

29.

59.

79.

59.

710

.010

.310

.010

.210

.510

.8H

I PR

217

233

246

257

243

262

276

288

276

297

314

328

315

339

358

373

354

381

402

420

391

421

445

464

LO P

R11

612

313

414

312

213

014

215

112

713

514

715

713

314

215

516

514

014

916

217

314

515

416

817

9

85

1347

MBh

36.1

36.8

38.6

41.1

35.3

36.0

37.7

40.2

34.4

35.1

36.8

39.2

33.6

34.3

35.9

38.3

31.9

32.5

34.1

36.4

29.6

30.1

31.6

33.7

S/T

1.00

1.00

0.92

0.74

1.00

1.00

0.95

0.77

1.00

1.00

0.97

0.79

1.00

1.00

1.00

0.82

1.00

1.00

1.00

0.85

1.00

1.00

1.00

0.85

Del

ta T

2525

2421

2425

2421

2424

2421

2323

2421

2222

2321

2021

2220

KW2.

142.

182.

252.

322.

292.

342.

412.

492.

432.

482.

562.

642.

562.

612.

692.

782.

662.

722.

802.

902.

752.

812.

903.

00AM

PS7.

77.

98.

18.

38.

28.

48.

68.

98.

89.

09.

29.

59.

39.

59.

710

.19.

810

.010

.310

.610

.310

.510

.811

.1H

I PR

225

243

256

267

253

272

287

300

288

310

327

341

328

353

372

388

369

397

419

437

407

438

463

483

LO P

R12

012

814

014

912

713

514

815

713

214

115

316

313

914

816

117

214

515

516

918

015

016

017

518

6

1200

MBh

35.1

35.8

37.4

39.9

34.3

34.9

36.6

39.0

33.4

34.1

35.7

38.1

32.6

33.3

34.8

37.2

31.0

31.6

33.1

35.3

28.7

29.3

30.7

32.7

S/T

1.00

0.97

0.87

0.71

1.00

1.00

0.91

0.73

1.00

1.00

0.93

0.75

1.00

1.00

0.96

0.78

1.00

1.00

1.00

0.81

1.00

1.00

1.00

0.81

Del

ta T

2727

2522

2627

2522

2626

2522

2525

2622

2424

2522

2222

2320

KW2.

122.

162.

232.

302.

282.

322.

402.

472.

412.

462.

542.

622.

542.

592.

672.

762.

642.

702.

782.

872.

732.

792.

882.

97AM

PS7.

77.

88.

08.

38.

28.

38.

68.

88.

78.

99.

29.

49.

29.

49.

710

.09.

79.

910

.210

.510

.210

.410

.711

.1H

I PR

223

240

254

265

250

270

285

297

285

307

324

338

324

349

369

385

365

393

415

433

403

434

458

478

LO P

R11

912

713

814

712

613

414

615

613

113

915

216

213

714

616

017

014

415

316

717

814

915

817

318

4

1062

MBh

33.3

34.0

35.6

37.9

32.5

33.2

34.7

37.1

31.8

32.4

33.9

36.2

31.0

31.6

33.1

35.3

29.4

30.0

31.4

33.5

27.3

27.8

29.1

31.1

S/T

0.96

0.93

0.84

0.68

1.00

0.96

0.87

0.70

1.00

0.99

0.89

0.72

1.00

1.00

0.92

0.75

1.00

1.00

0.95

0.77

1.00

1.00

0.96

0.78

Del

ta T

2827

2622

2828

2623

2828

2623

2727

2623

2526

2622

2424

2421

KW2.

092.

132.

192.

262.

242.

292.

362.

432.

382.

432.

502.

582.

492.

552.

632.

712.

602.

652.

742.

832.

682.

742.

832.

92AM

PS7.

67.

77.

98.

18.

18.

28.

48.

78.

68.

89.

09.

39.

19.

39.

59.

89.

69.

810

.010

.410

.010

.210

.510

.9H

I PR

219

235

249

259

245

264

279

291

279

300

317

331

318

342

361

377

358

385

406

424

395

425

449

468

LO P

R11

712

413

614

412

313

114

315

312

813

614

915

913

514

315

616

714

115

016

417

514

615

517

018

1

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 13: DTH Commercial

SS-DTH3 www.daikinac.com 13

Expanded Cooling Data — 3 Tons (3-Phase Models) (cont.)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

1347

MBh

34.3

35.6

39.0

-33

.534

.738

.0-

32.7

33.9

37.1

-31

.933

.136

.2-

30.3

31.4

34.4

-28

.129

.131

.9-

S/T

0.81

0.67

0.47

-0.

830.

700.

48-

0.86

0.71

0.50

-0.

880.

740.

51-

0.92

0.77

0.53

-0.

920.

770.

53-

Del

ta T

1916

12-

1917

13-

1917

13-

1917

13-

1916

12-

1815

12-

KW2.

092.

132.

19-

2.24

2.29

2.36

-2.

382.

432.

50-

2.49

2.55

2.63

-2.

602.

652.

74-

2.68

2.74

2.83

-AM

PS7.

67.

77.

9-

8.1

8.2

8.4

-8.

68.

89.

0-

9.1

9.3

9.5

-9.

69.

810

.0-

10.0

10.2

10.5

-H

I PR

219

235

249

-24

526

427

9-

279

300

317

-31

834

236

1-

358

385

406

-39

542

544

9-

LO P

R11

712

413

6-

123

131

143

-12

813

614

9-

135

143

156

-14

115

016

4-

146

155

170

-

1200

MBh

33.3

34.5

37.8

-32

.533

.736

.9-

31.8

32.9

36.1

-31

.032

.135

.2-

29.4

30.5

33.4

-27

.328

.331

.0-

S/T

0.77

0.64

0.44

-0.

800.

660.

46-

0.82

0.68

0.47

-0.

840.

700.

49-

0.87

0.73

0.51

-0.

880.

740.

51-

Del

ta T

2017

13-

2017

13-

2017

13-

2017

13-

2017

13-

1816

12-

KW2.

072.

112.

18-

2.22

2.27

2.34

-2.

362.

412.

48-

2.48

2.53

2.61

-2.

582.

632.

71-

2.66

2.72

2.81

-AM

PS7.

57.

77.

9-

8.0

8.2

8.4

-8.

58.

78.

9-

9.0

9.2

9.5

-9.

59.

710

.0-

10.0

10.2

10.5

-H

I PR

217

233

246

-24

326

227

6-

276

297

314

-31

533

935

8-

354

381

402

-39

142

144

5-

LO P

R11

612

313

4-

122

130

142

-12

713

514

7-

133

142

155

-14

014

916

2-

145

154

168

-

1062

MBh

31.6

32.8

35.9

-30

.932

.035

.1-

30.2

31.3

34.3

-29

.430

.533

.4-

28.0

29.0

31.7

-25

.926

.829

.4-

S/T

0.74

0.61

0.43

-0.

760.

640.

44-

0.78

0.65

0.45

-0.

810.

670.

47-

0.84

0.70

0.48

-0.

840.

710.

49-

Del

ta T

2017

13-

2018

13-

2018

13-

2118

14-

2018

13-

1916

12-

KW2.

042.

082.

14-

2.19

2.23

2.30

-2.

322.

372.

44-

2.44

2.49

2.57

-2.

532.

592.

67-

2.62

2.67

2.76

-AM

PS7.

47.

67.

7-

7.9

8.0

8.2

-8.

48.

68.

8-

8.9

9.1

9.3

-9.

39.

59.

8-

9.8

10.0

10.3

-H

I PR

212

228

241

-23

825

627

1-

271

291

308

-30

833

235

1-

347

373

394

-38

341

343

6-

LO P

R11

312

113

2-

120

127

139

-12

413

214

4-

131

139

152

-13

714

615

9-

142

151

164

-

75

1347

MBh

34.9

35.9

38.9

41.7

34.1

35.1

38.0

40.8

33.3

34.2

37.1

39.8

32.4

33.4

36.2

38.8

30.8

31.7

34.4

36.9

28.6

29.4

31.8

34.2

S/T

0.92

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.97

0.87

0.66

0.42

1.00

0.90

0.68

0.44

1.00

0.93

0.71

0.45

1.00

0.94

0.71

0.46

Del

ta T

2220

1611

2220

1711

2220

1712

2220

1712

2120

1711

1919

1511

KW2.

102.

152.

212.

282.

262.

312.

382.

452.

402.

452.

522.

602.

522.

572.

652.

742.

622.

672.

762.

852.

712.

762.

852.

95AM

PS7.

67.

88.

08.

28.

18.

38.

58.

78.

78.

89.

19.

49.

29.

39.

69.

99.

69.

810

.110

.410

.110

.310

.611

.0H

I PR

221

238

251

262

248

267

282

294

282

303

320

334

321

346

365

381

361

389

411

428

399

430

454

473

LO P

R11

812

513

714

612

513

314

515

412

913

815

016

013

614

515

816

814

315

216

617

614

715

717

118

2

1200

MBh

33.9

34.9

37.7

40.5

33.1

34.1

36.9

39.6

32.3

33.2

36.0

38.6

31.5

32.4

35.1

37.7

29.9

30.8

33.4

35.8

27.7

28.5

30.9

33.2

S/T

0.87

0.78

0.59

0.38

0.90

0.81

0.61

0.39

0.93

0.83

0.63

0.40

0.96

0.86

0.65

0.42

0.99

0.89

0.67

0.43

1.00

0.90

0.68

0.44

Del

ta T

2321

1712

2321

1712

2321

1712

2321

1712

2321

1712

2120

1611

KW2.

092.

132.

192.

262.

242.

292.

362.

432.

382.

432.

502.

582.

502.

552.

632.

712.

602.

652.

742.

832.

682.

742.

832.

92AM

PS7.

67.

77.

98.

28.

18.

28.

48.

78.

68.

89.

09.

39.

19.

39.

59.

89.

69.

810

.010

.410

.010

.210

.510

.9H

I PR

219

235

249

259

245

264

279

291

279

300

317

331

318

342

361

377

358

385

407

424

395

425

449

468

LO P

R11

712

413

614

412

313

114

315

312

813

614

915

913

514

315

616

714

115

016

417

514

615

517

018

1

1062

MBh

32.2

33.1

35.9

38.5

31.4

32.4

35.0

37.6

30.7

31.6

34.2

36.7

29.9

30.8

33.4

35.8

28.4

29.3

31.7

34.0

26.3

27.1

29.4

31.5

S/T

0.84

0.75

0.57

0.36

0.87

0.78

0.59

0.38

0.89

0.79

0.60

0.39

0.92

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.96

0.86

0.65

0.42

Del

ta T

2321

1812

2422

1812

2422

1812

2422

1812

2322

1812

2220

1711

KW2.

062.

102.

162.

232.

212.

252.

322.

392.

342.

392.

462.

542.

462.

512.

592.

672.

552.

612.

692.

782.

642.

702.

782.

87AM

PS7.

57.

67.

88.

07.

98.

18.

38.

68.

58.

68.

99.

29.

09.

19.

49.

79.

49.

69.

910

.29.

910

.110

.410

.7H

I PR

214

231

244

254

241

259

273

285

274

294

311

324

312

335

354

369

351

377

398

416

387

417

440

459

LO P

R11

412

213

314

212

112

914

015

012

613

414

615

513

214

015

316

313

814

716

117

114

315

216

617

7ID

B =

Ente

ring

Indo

or D

ry B

ulb

Tem

pera

ture

Shad

ed a

rea

refle

cts

ACCA

(TVA

) con

ditio

nskW

= T

otal

sys

tem

pow

erH

igh

& lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d &

suc

tion

serv

ice

port

s.Am

ps: U

nit a

mps

(com

p.+

evap

orat

or +

con

dens

er fa

n m

otor

s)D

esig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

±3 °F

@ th

e co

mpr

esso

r suc

tion

acce

ss fi

tting

con

necti

on.

Out

door

Am

bien

t Tem

pera

ture

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Airfl

ow59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

1347

MBh

35.5

36.3

38.8

41.4

34.7

35.4

37.9

40.5

33.9

34.6

37.0

39.5

33.0

33.7

36.1

38.5

31.4

32.1

34.3

36.6

29.1

29.7

31.7

33.9

S/T

1.00

0.94

0.77

0.57

1.00

1.00

0.79

0.59

1.00

1.00

0.81

0.61

1.00

1.00

0.84

0.63

1.00

1.00

0.87

0.65

1.00

1.00

0.88

0.66

Del

ta T

2423

2016

2424

2116

2324

2116

2323

2117

2122

2016

2020

1915

KW2.

122.

162.

232.

302.

282.

322.

402.

472.

412.

462.

542.

622.

542.

592.

672.

762.

642.

702.

782.

872.

732.

792.

882.

97AM

PS7.

77.

88.

08.

38.

28.

38.

68.

88.

78.

99.

29.

49.

29.

49.

710

.09.

79.

910

.210

.510

.210

.410

.711

.1H

I PR

223

240

254

265

250

270

285

297

285

307

324

338

324

349

369

385

365

393

415

433

403

434

458

478

LO P

R11

912

713

814

712

613

414

615

613

113

915

216

213

714

616

017

014

415

316

717

814

915

817

318

4

1200

MBh

34.5

35.2

37.6

40.2

33.7

34.4

36.8

39.3

32.9

33.6

35.9

38.4

32.1

32.8

35.0

37.4

30.5

31.1

33.3

35.5

28.2

28.8

30.8

32.9

S/T

0.96

0.90

0.73

0.55

0.99

0.93

0.76

0.57

1.00

0.95

0.78

0.58

1.00

0.98

0.80

0.60

1.00

1.00

0.83

0.62

1.00

1.00

0.84

0.63

Del

ta T

2524

2117

2625

2117

2525

2117

2525

2217

2324

2117

2222

2016

KW2.

102.

152.

212.

282.

262.

312.

382.

452.

402.

452.

522.

602.

522.

572.

652.

742.

622.

672.

762.

852.

712.

762.

852.

95AM

PS7.

67.

88.

08.

28.

18.

38.

58.

78.

78.

89.

19.

49.

29.

39.

69.

99.

69.

810

.110

.410

.110

.310

.611

.0H

I PR

221

238

251

262

248

267

282

294

282

303

320

334

321

346

365

381

361

389

411

428

399

430

454

473

LO P

R11

812

513

714

612

513

314

515

413

013

815

016

013

614

515

816

814

315

216

617

614

715

717

118

2

1062

MBh

32.7

33.5

35.7

38.2

32.0

32.7

34.9

37.3

31.2

31.9

34.1

36.4

30.5

31.1

33.3

35.5

28.9

29.6

31.6

33.8

26.8

27.4

29.3

31.3

S/T

0.92

0.86

0.70

0.52

0.95

0.89

0.73

0.54

0.97

0.91

0.74

0.56

1.01

0.94

0.77

0.57

1.04

0.98

0.80

0.60

1.00

0.99

0.80

0.60

Del

ta T

2625

2217

2625

2218

2625

2218

2725

2218

2625

2217

2323

2016

KW2.

072.

112.

182.

242.

222.

272.

342.

412.

362.

412.

482.

562.

482.

532.

612.

692.

582.

632.

712.

802.

662.

722.

812.

90AM

PS7.

57.

77.

98.

18.

08.

28.

48.

68.

58.

78.

99.

29.

09.

29.

59.

79.

59.

710

.010

.310

.010

.210

.510

.8H

I PR

217

233

246

257

243

262

276

288

276

297

314

328

315

339

358

373

354

381

402

420

391

421

445

464

LO P

R11

612

313

414

312

213

014

215

112

713

514

715

713

314

215

516

514

014

916

217

314

515

416

817

9

85

1347

MBh

36.1

36.8

38.6

41.1

35.3

36.0

37.7

40.2

34.4

35.1

36.8

39.2

33.6

34.3

35.9

38.3

31.9

32.5

34.1

36.4

29.6

30.1

31.6

33.7

S/T

1.00

1.00

0.92

0.74

1.00

1.00

0.95

0.77

1.00

1.00

0.97

0.79

1.00

1.00

1.00

0.82

1.00

1.00

1.00

0.85

1.00

1.00

1.00

0.85

Del

ta T

2525

2421

2425

2421

2424

2421

2323

2421

2222

2321

2021

2220

KW2.

142.

182.

252.

322.

292.

342.

412.

492.

432.

482.

562.

642.

562.

612.

692.

782.

662.

722.

802.

902.

752.

812.

903.

00AM

PS7.

77.

98.

18.

38.

28.

48.

68.

98.

89.

09.

29.

59.

39.

59.

710

.19.

810

.010

.310

.610

.310

.510

.811

.1H

I PR

225

243

256

267

253

272

287

300

288

310

327

341

328

353

372

388

369

397

419

437

407

438

463

483

LO P

R12

012

814

014

912

713

514

815

713

214

115

316

313

914

816

117

214

515

516

918

015

016

017

518

6

1200

MBh

35.1

35.8

37.4

39.9

34.3

34.9

36.6

39.0

33.4

34.1

35.7

38.1

32.6

33.3

34.8

37.2

31.0

31.6

33.1

35.3

28.7

29.3

30.7

32.7

S/T

1.00

0.97

0.87

0.71

1.00

1.00

0.91

0.73

1.00

1.00

0.93

0.75

1.00

1.00

0.96

0.78

1.00

1.00

1.00

0.81

1.00

1.00

1.00

0.81

Del

ta T

2727

2522

2627

2522

2626

2522

2525

2622

2424

2522

2222

2320

KW2.

122.

162.

232.

302.

282.

322.

402.

472.

412.

462.

542.

622.

542.

592.

672.

762.

642.

702.

782.

872.

732.

792.

882.

97AM

PS7.

77.

88.

08.

38.

28.

38.

68.

88.

78.

99.

29.

49.

29.

49.

710

.09.

79.

910

.210

.510

.210

.410

.711

.1H

I PR

223

240

254

265

250

270

285

297

285

307

324

338

324

349

369

385

365

393

415

433

403

434

458

478

LO P

R11

912

713

814

712

613

414

615

613

113

915

216

213

714

616

017

014

415

316

717

814

915

817

318

4

1062

MBh

33.3

34.0

35.6

37.9

32.5

33.2

34.7

37.1

31.8

32.4

33.9

36.2

31.0

31.6

33.1

35.3

29.4

30.0

31.4

33.5

27.3

27.8

29.1

31.1

S/T

0.96

0.93

0.84

0.68

1.00

0.96

0.87

0.70

1.00

0.99

0.89

0.72

1.00

1.00

0.92

0.75

1.00

1.00

0.95

0.77

1.00

1.00

0.96

0.78

Del

ta T

2827

2622

2828

2623

2828

2623

2727

2623

2526

2622

2424

2421

KW2.

092.

132.

192.

262.

242.

292.

362.

432.

382.

432.

502.

582.

492.

552.

632.

712.

602.

652.

742.

832.

682.

742.

832.

92AM

PS7.

67.

77.

98.

18.

18.

28.

48.

78.

68.

89.

09.

39.

19.

39.

59.

89.

69.

810

.010

.410

.010

.210

.510

.9H

I PR

219

235

249

259

245

264

279

291

279

300

317

331

318

342

361

377

358

385

406

424

395

425

449

468

LO P

R11

712

413

614

412

313

114

315

312

813

614

915

913

514

315

616

714

115

016

417

514

615

517

018

1

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 14: DTH Commercial

14 www.daikinac.com SS-DTH3

Expanded Cooling Data — 4 Tons (3-Phase Models)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

1796

MBh

46.8

48.6

53.2

-45

.847

.452

.0-

44.7

46.3

50.7

-43

.645

.249

.5-

41.4

42.9

47.0

-38

.339

.743

.5-

S/T

0.76

0.64

0.44

-0.

790.

660.

46-

0.81

0.68

0.47

-0.

840.

700.

48-

0.87

0.73

0.50

-0.

880.

730.

51-

Del

ta T

1816

12-

1916

12-

1916

12-

1916

12-

1816

12-

1715

11-

KW2.

943.

003.

09-

3.16

3.23

3.33

-3.

363.

433.

54-

3.53

3.61

3.73

-3.

683.

763.

89-

3.81

3.89

4.02

-AM

PS9.

39.

49.

7-

9.8

10.0

10.3

-10

.510

.711

.0-

11.1

11.4

11.7

-11

.712

.012

.3-

12.3

12.6

12.9

-H

I PR

238

256

270

-26

728

730

3-

304

327

345

-34

637

239

3-

389

419

442

-43

046

348

8-

LO P

R11

211

913

0-

119

126

138

-12

313

114

3-

130

138

150

-13

614

415

8-

140

149

163

-

1600

MBh

45.5

47.1

51.6

-44

.446

.050

.4-

43.4

44.9

49.2

-42

.343

.948

.0-

40.2

41.7

45.6

-37

.238

.642

.3-

S/T

0.73

0.61

0.42

-0.

750.

630.

44-

0.77

0.65

0.45

-0.

800.

670.

46-

0.83

0.69

0.48

-0.

840.

700.

48-

Del

ta T

1916

13-

1917

13-

1917

13-

1917

13-

1917

13-

1815

12-

KW2.

922.

983.

07-

3.14

3.20

3.31

-3.

333.

413.

51-

3.51

3.58

3.70

-3.

653.

733.

85-

3.78

3.86

3.99

-AM

PS9.

29.

49.

6-

9.8

10.0

10.2

-10

.510

.711

.0-

11.0

11.3

11.6

-11

.611

.912

.2-

12.2

12.5

12.8

-H

I PR

236

253

268

-26

428

430

0-

301

323

342

-34

236

838

9-

385

414

438

-42

645

848

4-

LO P

R11

111

812

9-

117

125

136

-12

213

014

2-

128

136

149

-13

414

315

6-

139

148

161

-

1416

MBh

43.2

44.8

49.1

-42

.243

.747

.9-

41.2

42.7

46.8

-40

.241

.745

.6-

38.2

39.6

43.4

-35

.436

.740

.2-

S/T

0.70

0.58

0.40

-0.

720.

600.

42-

0.74

0.62

0.43

-0.

770.

640.

44-

0.79

0.66

0.46

-0.

800.

670.

46-

Del

ta T

2017

13-

2017

13-

2017

13-

2017

13-

2017

13-

1816

12-

KW2.

872.

933.

02-

3.09

3.15

3.25

-3.

283.

353.

46-

3.45

3.52

3.64

-3.

593.

673.

79-

3.72

3.80

3.92

-AM

PS9.

19.

29.

5-

9.6

9.8

10.1

-10

.310

.510

.8-

10.9

11.1

11.4

-11

.511

.712

.0-

12.0

12.3

12.6

-H

I PR

231

248

262

-25

927

929

4-

295

317

335

-33

636

138

1-

377

406

429

-41

744

947

4-

LO P

R10

911

612

7-

115

122

134

-12

012

713

9-

126

134

146

-13

214

015

3-

136

145

158

-

75

1796

MBh

47.6

49.1

53.1

57.0

46.5

47.9

51.9

55.7

45.4

46.8

50.6

54.3

44.3

45.6

49.4

53.0

42.1

43.3

46.9

50.4

39.0

40.2

43.5

46.6

S/T

0.87

0.78

0.59

0.38

0.90

0.80

0.61

0.39

0.92

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.99

0.88

0.67

0.43

1.00

0.89

0.67

0.43

Del

ta T

2119

1611

2120

1611

2120

1611

2220

1611

2120

1611

2018

1510

KW2.

963.

033.

123.

223.

193.

263.

363.

473.

393.

463.

573.

693.

563.

643.

763.

893.

713.

803.

924.

053.

843.

934.

064.

19AM

PS9.

39.

59.

710

.09.

910

.110

.410

.710

.610

.811

.111

.511

.211

.411

.812

.111

.812

.112

.412

.812

.412

.713

.013

.5H

I PR

240

259

273

285

270

290

306

320

307

330

349

364

349

376

397

414

393

423

447

466

434

467

493

515

LO P

R11

312

113

214

012

012

813

914

812

513

314

515

413

113

915

216

213

714

615

917

014

215

116

517

5

1600

MBh

46.3

47.6

51.5

55.3

45.2

46.5

50.3

54.0

44.1

45.4

49.1

52.8

43.0

44.3

48.0

51.5

40.9

42.1

45.6

48.9

37.9

39.0

42.2

45.3

S/T

0.83

0.74

0.56

0.36

0.86

0.77

0.58

0.37

0.88

0.79

0.60

0.38

0.91

0.81

0.61

0.40

0.94

0.84

0.64

0.41

0.95

0.85

0.64

0.41

Del

ta T

2220

1711

2221

1712

2221

1712

2221

1712

2220

1712

2119

1611

KW2.

943.

003.

103.

193.

163.

233.

333.

443.

363.

433.

543.

663.

533.

613.

733.

853.

683.

763.

894.

023.

813.

894.

024.

16AM

PS9.

39.

49.

710

.09.

910

.010

.310

.610

.510

.811

.011

.411

.111

.411

.712

.011

.712

.012

.312

.712

.312

.612

.913

.4H

I PR

238

256

270

282

267

287

303

316

304

327

345

360

346

372

393

410

389

419

442

461

430

463

489

510

LO P

R11

212

013

013

911

912

613

814

712

313

114

315

313

013

815

016

013

614

415

816

814

014

916

317

4

1416

MBh

43.9

45.2

49.0

52.6

42.9

44.2

47.8

51.3

41.9

43.1

46.7

50.1

40.9

42.1

45.6

48.9

38.8

40.0

43.3

46.4

36.0

37.0

40.1

43.0

S/T

0.79

0.71

0.54

0.35

0.82

0.73

0.56

0.36

0.84

0.75

0.57

0.37

0.87

0.78

0.59

0.38

0.90

0.81

0.61

0.39

0.91

0.81

0.62

0.40

Del

ta T

2321

1712

2321

1712

2321

1712

2321

1712

2321

1712

2120

1611

KW2.

892.

953.

053.

143.

113.

183.

283.

393.

313.

383.

493.

603.

483.

553.

673.

793.

623.

703.

823.

953.

753.

833.

964.

09AM

PS9.

19.

39.

59.

89.

79.

910

.210

.510

.410

.610

.911

.211

.011

.211

.511

.911

.511

.812

.112

.512

.112

.412

.713

.1H

I PR

233

251

265

276

262

282

297

310

298

320

338

353

339

365

385

402

381

410

433

452

421

453

479

499

LO P

R11

011

712

813

611

612

413

514

412

112

914

015

012

713

514

715

713

314

215

516

513

814

616

017

0ID

B =

Ente

ring

Indo

or D

ry B

ulb

Tem

pera

ture

Shad

ed a

rea

refle

cts

ACCA

(TVA

) con

ditio

nskW

= T

otal

sys

tem

pow

erH

igh

& lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d &

suc

tion

serv

ice

port

s.Am

ps: U

nit a

mps

(com

p.+

evap

orat

or +

con

dens

er fa

n m

otor

s)D

esig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

±3 °F

@ th

e co

mpr

esso

r suc

tion

acce

ss fi

tting

con

necti

on.

Out

door

Am

bien

t Tem

pera

ture

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Airfl

ow59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

1796

MBh

48.5

49.5

52.9

56.6

47.4

48.4

51.7

55.3

46.2

47.2

50.5

54.0

45.1

46.1

49.2

52.6

42.8

43.8

46.8

50.0

39.7

40.6

43.3

46.3

S/T

0.95

0.89

0.73

0.54

1.00

0.93

0.75

0.56

1.00

0.95

0.77

0.58

1.00

1.00

0.80

0.60

1.00

1.00

0.83

0.62

1.00

1.00

0.83

0.62

Del

ta T

2423

2016

2423

2016

2423

2016

2324

2016

2222

2016

2021

1915

KW2.

993.

053.

153.

253.

213.

283.

393.

503.

423.

493.

603.

723.

593.

673.

793.

923.

743.

833.

954.

093.

873.

964.

094.

23AM

PS9.

49.

69.

810

.110

.010

.210

.510

.810

.710

.911

.211

.611

.311

.511

.912

.211

.912

.212

.512

.912

.512

.813

.113

.6H

I PR

243

261

276

288

272

293

310

323

310

333

352

367

353

380

401

418

397

427

451

470

439

472

498

520

LO P

R11

512

213

314

212

112

914

115

012

613

414

615

613

214

115

416

313

914

716

117

114

315

216

617

7

1600

MBh

47.1

48.1

51.4

54.9

46.0

47.0

50.2

53.7

44.9

45.9

49.0

52.4

43.8

44.7

47.8

51.1

41.6

42.5

45.4

48.6

38.5

39.4

42.1

45.0

S/T

0.91

0.85

0.69

0.52

0.94

0.88

0.72

0.54

0.96

0.90

0.74

0.55

1.00

0.93

0.76

0.57

1.00

0.97

0.79

0.59

1.00

0.98

0.80

0.59

Del

ta T

2524

2016

2524

2117

2524

2117

2524

2117

2424

2116

2222

1915

KW2.

963.

033.

123.

223.

193.

263.

363.

473.

393.

463.

573.

693.

563.

643.

763.

893.

713.

803.

924.

053.

843.

934.

064.

19AM

PS9.

39.

59.

810

.09.

910

.110

.410

.710

.610

.811

.111

.511

.211

.511

.812

.111

.812

.112

.412

.812

.412

.713

.013

.5H

I PR

240

259

273

285

270

290

306

320

307

330

349

364

349

376

397

414

393

423

447

466

434

467

493

515

LO P

R11

312

113

214

012

012

813

914

812

513

314

515

413

113

915

216

213

714

615

917

014

215

116

517

5

1416

MBh

44.7

45.7

48.8

52.2

43.7

44.6

47.7

51.0

42.6

43.6

46.6

49.8

41.6

42.5

45.4

48.6

39.5

40.4

43.1

46.1

36.6

37.4

40.0

42.7

S/T

0.87

0.82

0.66

0.50

0.90

0.85

0.69

0.51

0.92

0.87

0.71

0.53

0.95

0.89

0.73

0.54

0.99

0.93

0.76

0.56

1.00

0.94

0.76

0.57

Del

ta T

2524

2117

2624

2117

2625

2117

2625

2117

2524

2117

2423

2016

KW2.

922.

983.

073.

173.

143.

203.

313.

413.

333.

413.

513.

633.

513.

583.

703.

823.

653.

733.

853.

983.

783.

863.

994.

12AM

PS9.

29.

49.

69.

99.

810

.010

.210

.510

.510

.711

.011

.311

.011

.311

.612

.011

.611

.912

.212

.612

.212

.512

.813

.3H

I PR

236

253

268

279

264

284

300

313

301

323

342

356

342

368

389

406

385

414

438

457

426

458

484

504

LO P

R11

111

812

913

811

712

513

614

512

213

014

215

112

813

614

915

913

414

315

616

613

914

816

117

2

85

1796

MBh

49.3

50.3

52.7

56.2

48.2

49.1

51.4

54.9

47.0

48.0

50.2

53.6

45.9

46.8

49.0

52.3

43.6

44.4

46.5

49.7

40.4

41.2

43.1

46.0

S/T

1.00

0.96

0.87

0.70

1.00

1.00

0.90

0.73

1.00

1.00

0.92

0.75

1.00

1.00

0.95

0.77

1.00

1.00

0.99

0.80

1.00

1.00

1.00

0.81

Del

ta T

2525

2320

2525

2421

2425

2421

2324

2421

2223

2420

2121

2219

KW3.

013.

073.

173.

273.

243.

313.

423.

533.

443.

523.

633.

753.

623.

703.

823.

953.

783.

863.

994.

123.

913.

994.

134.

27AM

PS9.

59.

69.

910

.210

.110

.310

.510

.910

.811

.011

.311

.711

.411

.612

.012

.312

.012

.312

.613

.012

.612

.913

.213

.7H

I PR

245

264

279

291

275

296

313

326

313

337

356

371

356

384

405

422

401

431

456

475

443

477

503

525

LO P

R11

612

313

414

312

213

014

215

112

713

514

815

713

414

215

516

514

014

916

217

314

515

416

817

9

1600

MBh

47.9

48.8

51.1

54.6

46.8

47.7

49.9

53.3

45.7

46.6

48.8

52.0

44.6

45.4

47.6

50.7

42.3

43.1

45.2

48.2

39.2

40.0

41.9

44.7

S/T

0.95

0.92

0.83

0.67

0.99

0.95

0.86

0.70

1.00

0.98

0.88

0.71

1.00

1.00

0.91

0.74

1.00

1.00

0.94

0.77

1.00

1.00

0.95

0.77

Del

ta T

2626

2421

2726

2521

2626

2521

2626

2522

2425

2421

2323

2320

KW2.

993.

053.

153.

253.

213.

283.

393.

503.

423.

493.

603.

723.

593.

673.

793.

923.

743.

833.

954.

093.

873.

964.

094.

23AM

PS9.

49.

69.

810

.110

.010

.210

.510

.810

.710

.911

.211

.611

.311

.511

.912

.211

.912

.212

.512

.912

.512

.813

.113

.6H

I PR

243

261

276

288

272

293

310

323

310

333

352

367

353

380

401

418

397

427

451

470

439

472

498

520

LO P

R11

512

213

314

212

112

914

115

012

613

414

615

613

214

115

416

313

914

716

117

114

315

216

617

7

1416

MBh

45.5

46.4

48.6

51.8

44.4

45.3

47.4

50.6

43.4

44.2

46.3

49.4

42.3

43.1

45.2

48.2

40.2

41.0

42.9

45.8

37.2

38.0

39.8

42.4

S/T

0.91

0.88

0.79

0.64

0.94

0.91

0.82

0.67

0.97

0.93

0.84

0.68

1.00

0.96

0.87

0.71

1.00

1.00

0.90

0.73

1.00

1.00

0.91

0.74

Del

ta T

2726

2522

2727

2522

2727

2522

2727

2622

2627

2522

2425

2420

KW2.

943.

003.

093.

193.

163.

233.

333.

443.

363.

433.

543.

663.

533.

613.

733.

853.

683.

763.

894.

023.

813.

894.

024.

16AM

PS9.

39.

49.

710

.09.

810

.010

.310

.610

.510

.711

.011

.411

.111

.411

.712

.011

.712

.012

.312

.712

.312

.612

.913

.4H

I PR

238

256

270

282

267

287

303

316

304

327

345

360

346

372

393

410

389

419

442

461

430

463

488

509

LO P

R11

211

913

013

911

912

613

814

712

313

114

315

313

013

815

016

013

614

415

816

814

014

916

317

4

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 15: DTH Commercial

SS-DTH3 www.daikinac.com 15

Expanded Cooling Data — 4 Tons (3-Phase Models) (cont.)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

1796

MBh

46.8

48.6

53.2

-45

.847

.452

.0-

44.7

46.3

50.7

-43

.645

.249

.5-

41.4

42.9

47.0

-38

.339

.743

.5-

S/T

0.76

0.64

0.44

-0.

790.

660.

46-

0.81

0.68

0.47

-0.

840.

700.

48-

0.87

0.73

0.50

-0.

880.

730.

51-

Del

ta T

1816

12-

1916

12-

1916

12-

1916

12-

1816

12-

1715

11-

KW2.

943.

003.

09-

3.16

3.23

3.33

-3.

363.

433.

54-

3.53

3.61

3.73

-3.

683.

763.

89-

3.81

3.89

4.02

-AM

PS9.

39.

49.

7-

9.8

10.0

10.3

-10

.510

.711

.0-

11.1

11.4

11.7

-11

.712

.012

.3-

12.3

12.6

12.9

-H

I PR

238

256

270

-26

728

730

3-

304

327

345

-34

637

239

3-

389

419

442

-43

046

348

8-

LO P

R11

211

913

0-

119

126

138

-12

313

114

3-

130

138

150

-13

614

415

8-

140

149

163

-

1600

MBh

45.5

47.1

51.6

-44

.446

.050

.4-

43.4

44.9

49.2

-42

.343

.948

.0-

40.2

41.7

45.6

-37

.238

.642

.3-

S/T

0.73

0.61

0.42

-0.

750.

630.

44-

0.77

0.65

0.45

-0.

800.

670.

46-

0.83

0.69

0.48

-0.

840.

700.

48-

Del

ta T

1916

13-

1917

13-

1917

13-

1917

13-

1917

13-

1815

12-

KW2.

922.

983.

07-

3.14

3.20

3.31

-3.

333.

413.

51-

3.51

3.58

3.70

-3.

653.

733.

85-

3.78

3.86

3.99

-AM

PS9.

29.

49.

6-

9.8

10.0

10.2

-10

.510

.711

.0-

11.0

11.3

11.6

-11

.611

.912

.2-

12.2

12.5

12.8

-H

I PR

236

253

268

-26

428

430

0-

301

323

342

-34

236

838

9-

385

414

438

-42

645

848

4-

LO P

R11

111

812

9-

117

125

136

-12

213

014

2-

128

136

149

-13

414

315

6-

139

148

161

-

1416

MBh

43.2

44.8

49.1

-42

.243

.747

.9-

41.2

42.7

46.8

-40

.241

.745

.6-

38.2

39.6

43.4

-35

.436

.740

.2-

S/T

0.70

0.58

0.40

-0.

720.

600.

42-

0.74

0.62

0.43

-0.

770.

640.

44-

0.79

0.66

0.46

-0.

800.

670.

46-

Del

ta T

2017

13-

2017

13-

2017

13-

2017

13-

2017

13-

1816

12-

KW2.

872.

933.

02-

3.09

3.15

3.25

-3.

283.

353.

46-

3.45

3.52

3.64

-3.

593.

673.

79-

3.72

3.80

3.92

-AM

PS9.

19.

29.

5-

9.6

9.8

10.1

-10

.310

.510

.8-

10.9

11.1

11.4

-11

.511

.712

.0-

12.0

12.3

12.6

-H

I PR

231

248

262

-25

927

929

4-

295

317

335

-33

636

138

1-

377

406

429

-41

744

947

4-

LO P

R10

911

612

7-

115

122

134

-12

012

713

9-

126

134

146

-13

214

015

3-

136

145

158

-

75

1796

MBh

47.6

49.1

53.1

57.0

46.5

47.9

51.9

55.7

45.4

46.8

50.6

54.3

44.3

45.6

49.4

53.0

42.1

43.3

46.9

50.4

39.0

40.2

43.5

46.6

S/T

0.87

0.78

0.59

0.38

0.90

0.80

0.61

0.39

0.92

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.99

0.88

0.67

0.43

1.00

0.89

0.67

0.43

Del

ta T

2119

1611

2120

1611

2120

1611

2220

1611

2120

1611

2018

1510

KW2.

963.

033.

123.

223.

193.

263.

363.

473.

393.

463.

573.

693.

563.

643.

763.

893.

713.

803.

924.

053.

843.

934.

064.

19AM

PS9.

39.

59.

710

.09.

910

.110

.410

.710

.610

.811

.111

.511

.211

.411

.812

.111

.812

.112

.412

.812

.412

.713

.013

.5H

I PR

240

259

273

285

270

290

306

320

307

330

349

364

349

376

397

414

393

423

447

466

434

467

493

515

LO P

R11

312

113

214

012

012

813

914

812

513

314

515

413

113

915

216

213

714

615

917

014

215

116

517

5

1600

MBh

46.3

47.6

51.5

55.3

45.2

46.5

50.3

54.0

44.1

45.4

49.1

52.8

43.0

44.3

48.0

51.5

40.9

42.1

45.6

48.9

37.9

39.0

42.2

45.3

S/T

0.83

0.74

0.56

0.36

0.86

0.77

0.58

0.37

0.88

0.79

0.60

0.38

0.91

0.81

0.61

0.40

0.94

0.84

0.64

0.41

0.95

0.85

0.64

0.41

Del

ta T

2220

1711

2221

1712

2221

1712

2221

1712

2220

1712

2119

1611

KW2.

943.

003.

103.

193.

163.

233.

333.

443.

363.

433.

543.

663.

533.

613.

733.

853.

683.

763.

894.

023.

813.

894.

024.

16AM

PS9.

39.

49.

710

.09.

910

.010

.310

.610

.510

.811

.011

.411

.111

.411

.712

.011

.712

.012

.312

.712

.312

.612

.913

.4H

I PR

238

256

270

282

267

287

303

316

304

327

345

360

346

372

393

410

389

419

442

461

430

463

489

510

LO P

R11

212

013

013

911

912

613

814

712

313

114

315

313

013

815

016

013

614

415

816

814

014

916

317

4

1416

MBh

43.9

45.2

49.0

52.6

42.9

44.2

47.8

51.3

41.9

43.1

46.7

50.1

40.9

42.1

45.6

48.9

38.8

40.0

43.3

46.4

36.0

37.0

40.1

43.0

S/T

0.79

0.71

0.54

0.35

0.82

0.73

0.56

0.36

0.84

0.75

0.57

0.37

0.87

0.78

0.59

0.38

0.90

0.81

0.61

0.39

0.91

0.81

0.62

0.40

Del

ta T

2321

1712

2321

1712

2321

1712

2321

1712

2321

1712

2120

1611

KW2.

892.

953.

053.

143.

113.

183.

283.

393.

313.

383.

493.

603.

483.

553.

673.

793.

623.

703.

823.

953.

753.

833.

964.

09AM

PS9.

19.

39.

59.

89.

79.

910

.210

.510

.410

.610

.911

.211

.011

.211

.511

.911

.511

.812

.112

.512

.112

.412

.713

.1H

I PR

233

251

265

276

262

282

297

310

298

320

338

353

339

365

385

402

381

410

433

452

421

453

479

499

LO P

R11

011

712

813

611

612

413

514

412

112

914

015

012

713

514

715

713

314

215

516

513

814

616

017

0ID

B =

Ente

ring

Indo

or D

ry B

ulb

Tem

pera

ture

Shad

ed a

rea

refle

cts

ACCA

(TVA

) con

ditio

nskW

= T

otal

sys

tem

pow

erH

igh

& lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d &

suc

tion

serv

ice

port

s.Am

ps: U

nit a

mps

(com

p.+

evap

orat

or +

con

dens

er fa

n m

otor

s)D

esig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

±3 °F

@ th

e co

mpr

esso

r suc

tion

acce

ss fi

tting

con

necti

on.

Out

door

Am

bien

t Tem

pera

ture

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Airfl

ow59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

1796

MBh

48.5

49.5

52.9

56.6

47.4

48.4

51.7

55.3

46.2

47.2

50.5

54.0

45.1

46.1

49.2

52.6

42.8

43.8

46.8

50.0

39.7

40.6

43.3

46.3

S/T

0.95

0.89

0.73

0.54

1.00

0.93

0.75

0.56

1.00

0.95

0.77

0.58

1.00

1.00

0.80

0.60

1.00

1.00

0.83

0.62

1.00

1.00

0.83

0.62

Del

ta T

2423

2016

2423

2016

2423

2016

2324

2016

2222

2016

2021

1915

KW2.

993.

053.

153.

253.

213.

283.

393.

503.

423.

493.

603.

723.

593.

673.

793.

923.

743.

833.

954.

093.

873.

964.

094.

23AM

PS9.

49.

69.

810

.110

.010

.210

.510

.810

.710

.911

.211

.611

.311

.511

.912

.211

.912

.212

.512

.912

.512

.813

.113

.6H

I PR

243

261

276

288

272

293

310

323

310

333

352

367

353

380

401

418

397

427

451

470

439

472

498

520

LO P

R11

512

213

314

212

112

914

115

012

613

414

615

613

214

115

416

313

914

716

117

114

315

216

617

7

1600

MBh

47.1

48.1

51.4

54.9

46.0

47.0

50.2

53.7

44.9

45.9

49.0

52.4

43.8

44.7

47.8

51.1

41.6

42.5

45.4

48.6

38.5

39.4

42.1

45.0

S/T

0.91

0.85

0.69

0.52

0.94

0.88

0.72

0.54

0.96

0.90

0.74

0.55

1.00

0.93

0.76

0.57

1.00

0.97

0.79

0.59

1.00

0.98

0.80

0.59

Del

ta T

2524

2016

2524

2117

2524

2117

2524

2117

2424

2116

2222

1915

KW2.

963.

033.

123.

223.

193.

263.

363.

473.

393.

463.

573.

693.

563.

643.

763.

893.

713.

803.

924.

053.

843.

934.

064.

19AM

PS9.

39.

59.

810

.09.

910

.110

.410

.710

.610

.811

.111

.511

.211

.511

.812

.111

.812

.112

.412

.812

.412

.713

.013

.5H

I PR

240

259

273

285

270

290

306

320

307

330

349

364

349

376

397

414

393

423

447

466

434

467

493

515

LO P

R11

312

113

214

012

012

813

914

812

513

314

515

413

113

915

216

213

714

615

917

014

215

116

517

5

1416

MBh

44.7

45.7

48.8

52.2

43.7

44.6

47.7

51.0

42.6

43.6

46.6

49.8

41.6

42.5

45.4

48.6

39.5

40.4

43.1

46.1

36.6

37.4

40.0

42.7

S/T

0.87

0.82

0.66

0.50

0.90

0.85

0.69

0.51

0.92

0.87

0.71

0.53

0.95

0.89

0.73

0.54

0.99

0.93

0.76

0.56

1.00

0.94

0.76

0.57

Del

ta T

2524

2117

2624

2117

2625

2117

2625

2117

2524

2117

2423

2016

KW2.

922.

983.

073.

173.

143.

203.

313.

413.

333.

413.

513.

633.

513.

583.

703.

823.

653.

733.

853.

983.

783.

863.

994.

12AM

PS9.

29.

49.

69.

99.

810

.010

.210

.510

.510

.711

.011

.311

.011

.311

.612

.011

.611

.912

.212

.612

.212

.512

.813

.3H

I PR

236

253

268

279

264

284

300

313

301

323

342

356

342

368

389

406

385

414

438

457

426

458

484

504

LO P

R11

111

812

913

811

712

513

614

512

213

014

215

112

813

614

915

913

414

315

616

613

914

816

117

2

85

1796

MBh

49.3

50.3

52.7

56.2

48.2

49.1

51.4

54.9

47.0

48.0

50.2

53.6

45.9

46.8

49.0

52.3

43.6

44.4

46.5

49.7

40.4

41.2

43.1

46.0

S/T

1.00

0.96

0.87

0.70

1.00

1.00

0.90

0.73

1.00

1.00

0.92

0.75

1.00

1.00

0.95

0.77

1.00

1.00

0.99

0.80

1.00

1.00

1.00

0.81

Del

ta T

2525

2320

2525

2421

2425

2421

2324

2421

2223

2420

2121

2219

KW3.

013.

073.

173.

273.

243.

313.

423.

533.

443.

523.

633.

753.

623.

703.

823.

953.

783.

863.

994.

123.

913.

994.

134.

27AM

PS9.

59.

69.

910

.210

.110

.310

.510

.910

.811

.011

.311

.711

.411

.612

.012

.312

.012

.312

.613

.012

.612

.913

.213

.7H

I PR

245

264

279

291

275

296

313

326

313

337

356

371

356

384

405

422

401

431

456

475

443

477

503

525

LO P

R11

612

313

414

312

213

014

215

112

713

514

815

713

414

215

516

514

014

916

217

314

515

416

817

9

1600

MBh

47.9

48.8

51.1

54.6

46.8

47.7

49.9

53.3

45.7

46.6

48.8

52.0

44.6

45.4

47.6

50.7

42.3

43.1

45.2

48.2

39.2

40.0

41.9

44.7

S/T

0.95

0.92

0.83

0.67

0.99

0.95

0.86

0.70

1.00

0.98

0.88

0.71

1.00

1.00

0.91

0.74

1.00

1.00

0.94

0.77

1.00

1.00

0.95

0.77

Del

ta T

2626

2421

2726

2521

2626

2521

2626

2522

2425

2421

2323

2320

KW2.

993.

053.

153.

253.

213.

283.

393.

503.

423.

493.

603.

723.

593.

673.

793.

923.

743.

833.

954.

093.

873.

964.

094.

23AM

PS9.

49.

69.

810

.110

.010

.210

.510

.810

.710

.911

.211

.611

.311

.511

.912

.211

.912

.212

.512

.912

.512

.813

.113

.6H

I PR

243

261

276

288

272

293

310

323

310

333

352

367

353

380

401

418

397

427

451

470

439

472

498

520

LO P

R11

512

213

314

212

112

914

115

012

613

414

615

613

214

115

416

313

914

716

117

114

315

216

617

7

1416

MBh

45.5

46.4

48.6

51.8

44.4

45.3

47.4

50.6

43.4

44.2

46.3

49.4

42.3

43.1

45.2

48.2

40.2

41.0

42.9

45.8

37.2

38.0

39.8

42.4

S/T

0.91

0.88

0.79

0.64

0.94

0.91

0.82

0.67

0.97

0.93

0.84

0.68

1.00

0.96

0.87

0.71

1.00

1.00

0.90

0.73

1.00

1.00

0.91

0.74

Del

ta T

2726

2522

2727

2522

2727

2522

2727

2622

2627

2522

2425

2420

KW2.

943.

003.

093.

193.

163.

233.

333.

443.

363.

433.

543.

663.

533.

613.

733.

853.

683.

763.

894.

023.

813.

894.

024.

16AM

PS9.

39.

49.

710

.09.

810

.010

.310

.610

.510

.711

.011

.411

.111

.411

.712

.011

.712

.012

.312

.712

.312

.612

.913

.4H

I PR

238

256

270

282

267

287

303

316

304

327

345

360

346

372

393

410

389

419

442

461

430

463

488

509

LO P

R11

211

913

013

911

912

613

814

712

313

114

315

313

013

815

016

013

614

415

816

814

014

916

317

4

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 16: DTH Commercial

16 www.daikinac.com SS-DTH3

Expanded Cooling Data — 5 Tons (3-Phase Models)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

2244

MBh

58.8

60.9

66.8

-57

.459

.565

.2-

56.1

58.1

63.7

-54

.756

.762

.1-

52.0

53.9

59.0

-48

.149

.954

.7-

S/T

0.75

0.63

0.44

-0.

780.

650.

45-

0.80

0.67

0.46

-0.

830.

690.

48-

0.86

0.72

0.50

-0.

860.

720.

50-

Del

ta T

1816

12-

1816

12-

1816

12-

1916

12-

1816

12-

1715

11-

KW3.

753.

833.

94-

4.03

4.11

4.24

-4.

274.

364.

50-

4.49

4.58

4.73

-4.

674.

774.

92-

4.83

4.93

5.09

-AM

PS12

.012

.212

.5-

12.8

13.0

13.3

-13

.613

.914

.3-

14.4

14.7

15.1

-15

.115

.415

.8-

15.9

16.2

16.6

-H

I PR

231

249

263

-26

027

929

5-

295

318

335

-33

636

238

2-

378

407

430

-41

845

047

5-

LO P

R11

211

913

0-

119

126

138

-12

313

114

3-

130

138

150

-13

614

415

8-

140

149

163

-

1961

MBh

57.1

59.2

64.8

-55

.857

.863

.3-

54.4

56.4

61.8

-53

.155

.060

.3-

50.4

52.3

57.3

-46

.748

.453

.1-

S/T

0.72

0.60

0.42

-0.

740.

620.

43-

0.76

0.64

0.44

-0.

790.

660.

46-

0.82

0.68

0.47

-0.

820.

690.

48-

Del

ta T

1917

13-

1917

13-

1917

13-

2017

13-

1917

13-

1816

12-

KW3.

723.

803.

91-

4.00

4.08

4.20

-4.

244.

334.

46-

4.45

4.54

4.69

-4.

634.

734.

88-

4.79

4.89

5.05

-AM

PS11

.912

.112

.5-

12.7

12.9

13.2

-13

.513

.814

.2-

14.3

14.5

14.9

-15

.015

.315

.7-

15.7

16.1

16.5

-H

I PR

229

246

260

-25

727

729

2-

292

315

332

-33

335

837

8-

374

403

426

-41

444

547

0-

LO P

R11

111

812

9-

117

125

136

-12

213

014

2-

128

136

149

-13

414

315

6-

139

148

161

-

1770

MBh

56.2

58.3

63.9

-54

.956

.962

.4-

53.6

55.6

60.9

-52

.354

.259

.4-

49.7

51.5

56.4

-46

.047

.752

.3-

S/T

0.69

0.58

0.40

-0.

720.

600.

42-

0.74

0.61

0.43

-0.

760.

630.

44-

0.79

0.66

0.46

-0.

800.

660.

46-

Del

ta T

2018

13-

2018

13-

2118

13-

2118

14-

2018

13-

1916

12-

KW3.

683.

753.

86-

3.94

4.02

4.15

-4.

184.

274.

40-

4.39

4.48

4.62

-4.

574.

664.

81-

4.72

4.82

4.98

-AM

PS11

.812

.012

.3-

12.5

12.8

13.1

-13

.413

.614

.0-

14.1

14.4

14.7

-14

.815

.115

.5-

15.5

15.8

16.3

-H

I PR

225

242

256

-25

327

228

7-

287

309

326

-32

735

237

2-

368

396

418

-40

743

846

2-

LO P

R10

911

612

7-

115

123

134

-12

012

813

9-

126

134

146

-13

214

115

3-

137

145

159

-

75

2244

MBh

59.8

61.6

66.6

71.5

58.4

60.1

65.1

69.9

57.0

58.7

63.5

68.2

55.6

57.3

62.0

66.5

52.8

54.4

58.9

63.2

48.9

50.4

54.5

58.5

S/T

0.86

0.77

0.58

0.37

0.89

0.79

0.60

0.39

0.91

0.81

0.62

0.40

0.94

0.84

0.64

0.41

0.97

0.87

0.66

0.42

0.98

0.88

0.67

0.43

Del

ta T

2119

1611

2120

1611

2120

1611

2120

1611

2119

1611

2018

1510

KW3.

783.

863.

974.

104.

064.

144.

274.

414.

304.

404.

534.

684.

524.

624.

764.

924.

714.

814.

965.

124.

864.

975.

135.

30AM

PS12

.112

.312

.613

.012

.913

.113

.413

.813

.714

.014

.414

.814

.514

.815

.215

.615

.215

.516

.016

.516

.016

.316

.817

.3H

I PR

234

251

266

277

262

282

298

311

298

321

339

353

340

366

386

403

382

411

434

453

422

454

480

500

LO P

R11

312

113

214

012

012

813

914

812

513

314

515

413

113

915

216

213

714

615

917

014

215

116

517

5

1961

MBh

58.1

59.8

64.7

69.4

56.7

58.4

63.2

67.8

55.4

57.0

61.7

66.2

54.0

55.6

60.2

64.6

51.3

52.8

57.2

61.4

47.5

48.9

53.0

56.8

S/T

0.82

0.73

0.55

0.36

0.85

0.76

0.57

0.37

0.87

0.78

0.59

0.38

0.90

0.80

0.61

0.39

0.93

0.83

0.63

0.40

0.94

0.84

0.63

0.41

Del

ta T

2220

1712

2221

1712

2321

1712

2321

1712

2221

1712

2119

1611

KW3.

753.

833.

944.

064.

034.

114.

244.

374.

274.

364.

504.

644.

494.

584.

734.

884.

674.

774.

925.

084.

834.

935.

095.

26AM

PS12

.012

.212

.512

.912

.813

.013

.313

.713

.613

.914

.314

.714

.414

.715

.115

.515

.115

.415

.916

.315

.916

.216

.617

.2H

I PR

231

249

263

274

260

279

295

308

295

318

336

350

336

362

382

399

378

407

430

448

418

450

475

495

LO P

R11

212

013

013

911

912

613

814

712

313

114

315

313

013

815

016

013

614

415

816

814

014

916

317

4

1770

MBh

57.2

58.9

63.7

68.4

55.8

57.5

62.2

66.8

54.5

56.1

60.8

65.2

53.2

54.8

59.3

63.6

50.5

52.0

56.3

60.4

46.8

48.2

52.2

56.0

S/T

0.79

0.70

0.53

0.34

0.82

0.73

0.55

0.36

0.84

0.75

0.57

0.36

0.86

0.77

0.58

0.38

0.90

0.80

0.61

0.39

0.90

0.81

0.61

0.39

Del

ta T

2322

1812

2422

1812

2422

1812

2422

1812

2422

1812

2220

1711

KW3.

703.

783.

894.

013.

974.

064.

184.

314.

214.

304.

444.

584.

424.

524.

664.

814.

604.

704.

855.

014.

764.

865.

025.

18AM

PS11

.912

.112

.412

.712

.612

.813

.213

.613

.513

.714

.114

.514

.214

.514

.915

.314

.915

.215

.616

.115

.716

.016

.416

.9H

I PR

227

245

258

270

255

275

290

302

290

312

330

344

331

356

376

392

372

400

423

441

411

442

467

487

LO P

R11

011

712

813

711

712

413

514

412

112

914

115

012

713

514

815

813

314

215

516

513

814

716

017

1ID

B =

Ente

ring

Indo

or D

ry B

ulb

Tem

pera

ture

Shad

ed a

rea

refle

cts

ACCA

(TVA

) con

ditio

nskW

= T

otal

sys

tem

pow

erH

igh

& lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d &

suc

tion

serv

ice

port

s.Am

ps: U

nit a

mps

(com

p.+

evap

orat

or +

con

dens

er fa

n m

otor

s)D

esig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

±3 °F

@ th

e co

mpr

esso

r suc

tion

acce

ss fi

tting

con

necti

on.

Out

door

Am

bien

t Tem

pera

ture

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Airfl

ow59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

2244

MBh

60.9

62.2

66.4

71.0

59.4

60.7

64.9

69.4

58.0

59.3

63.3

67.7

56.6

57.8

61.8

66.1

53.8

55.0

58.7

62.8

49.8

50.9

54.4

58.1

S/T

0.94

0.88

0.72

0.54

1.00

0.91

0.74

0.56

1.00

0.94

0.76

0.57

1.00

0.97

0.79

0.59

1.00

1.00

0.82

0.61

1.00

1.00

0.82

0.62

Del

ta T

2322

2016

2423

2016

2423

2016

2323

2016

2223

2016

2021

1815

KW3.

813.

894.

004.

134.

094.

184.

304.

444.

344.

434.

574.

724.

564.

664.

804.

964.

744.

855.

005.

174.

905.

015.

175.

34AM

PS12

.212

.412

.713

.112

.913

.213

.513

.913

.814

.114

.514

.914

.614

.915

.315

.815

.415

.716

.116

.616

.116

.416

.917

.4H

I PR

236

254

268

280

265

285

301

314

301

324

342

357

343

369

390

407

386

415

439

457

426

459

485

505

LO P

R11

512

213

314

212

112

914

115

012

613

414

615

613

214

115

416

313

914

716

117

114

315

216

617

7

1961

MBh

59.1

60.4

64.5

69.0

57.7

59.0

63.0

67.3

56.3

57.6

61.5

65.7

55.0

56.2

60.0

64.1

52.2

53.4

57.0

60.9

48.4

49.4

52.8

56.4

S/T

0.90

0.84

0.68

0.51

0.93

0.87

0.71

0.53

0.95

0.89

0.73

0.54

0.98

0.92

0.75

0.56

1.00

0.96

0.78

0.58

1.00

0.96

0.78

0.59

Del

ta T

2524

2117

2524

2117

2524

2117

2524

2117

2424

2117

2322

1916

KW3.

783.

863.

974.

104.

064.

144.

274.

414.

304.

404.

534.

684.

524.

624.

774.

924.

714.

814.

965.

124.

874.

975.

135.

30AM

PS12

.112

.312

.613

.012

.913

.113

.413

.813

.714

.014

.414

.814

.514

.815

.215

.615

.215

.516

.016

.516

.016

.316

.817

.3H

I PR

234

251

266

277

262

282

298

311

298

321

339

353

340

366

386

403

382

411

434

453

422

454

480

500

LO P

R11

312

113

214

012

012

813

914

812

513

314

515

413

113

915

216

213

714

615

917

014

215

116

517

5

1770

MBh

58.2

59.5

63.5

67.9

56.8

58.1

62.1

66.3

55.5

56.7

60.6

64.8

54.1

55.3

59.1

63.2

51.4

52.6

56.1

60.0

47.6

48.7

52.0

55.6

S/T

0.86

0.81

0.66

0.49

0.90

0.84

0.68

0.51

0.92

0.86

0.70

0.52

0.95

0.89

0.72

0.54

0.98

0.92

0.75

0.56

0.99

0.93

0.76

0.57

Del

ta T

2625

2217

2625

2218

2625

2218

2726

2218

2625

2217

2524

2016

KW3.

733.

813.

924.

044.

014.

094.

214.

354.

254.

344.

474.

614.

464.

564.

704.

854.

644.

744.

895.

054.

804.

905.

065.

23AM

PS12

.012

.212

.512

.812

.712

.913

.313

.713

.613

.814

.214

.614

.314

.615

.015

.415

.015

.315

.816

.315

.816

.116

.517

.1H

I PR

230

247

261

272

258

277

293

306

293

315

333

347

334

359

379

396

376

404

427

445

415

447

472

492

LO P

R11

211

913

013

811

812

513

714

612

213

014

215

112

913

714

915

913

514

315

716

713

914

816

217

2

85

2244

MBh

61.9

63.1

66.1

70.5

60.5

61.6

64.6

68.9

59.0

60.2

63.0

67.2

57.6

58.7

61.5

65.6

54.7

55.8

58.4

62.3

50.7

51.7

54.1

57.7

S/T

0.98

0.95

0.86

0.70

1.00

0.98

0.89

0.72

1.00

1.00

0.91

0.74

1.00

1.00

0.94

0.76

1.00

1.00

0.98

0.79

1.00

1.00

0.98

0.80

Del

ta T

2525

2320

2525

2420

2425

2420

2424

2421

2223

2320

2121

2219

KW3.

843.

924.

044.

164.

124.

214.

344.

484.

374.

474.

614.

754.

594.

694.

845.

004.

784.

895.

045.

214.

945.

055.

225.

39AM

PS12

.312

.512

.813

.213

.013

.313

.614

.013

.914

.214

.615

.014

.715

.015

.415

.915

.515

.816

.216

.716

.216

.617

.017

.6H

I PR

238

257

271

283

268

288

304

317

304

327

346

361

347

373

394

411

390

420

443

462

431

464

489

510

LO P

R11

612

313

414

312

213

014

215

112

713

514

815

713

414

215

516

514

014

916

217

314

515

416

817

9

1961

MBh

60.1

61.3

64.2

68.5

58.7

59.9

62.7

66.9

57.3

58.4

61.2

65.3

55.9

57.0

59.7

63.7

53.1

54.2

56.7

60.5

49.2

50.2

52.5

56.0

S/T

0.94

0.91

0.82

0.66

0.97

0.94

0.85

0.69

1.00

0.96

0.87

0.71

1.00

0.99

0.90

0.73

1.00

1.00

0.93

0.76

1.00

1.00

0.94

0.76

Del

ta T

2626

2521

2726

2522

2726

2522

2627

2522

2525

2521

2324

2320

KW3.

813.

894.

004.

134.

094.

184.

304.

444.

344.

434.

574.

724.

564.

664.

804.

964.

744.

855.

005.

174.

905.

015.

175.

34AM

PS12

.212

.412

.713

.112

.913

.213

.513

.913

.814

.114

.514

.914

.614

.915

.315

.815

.415

.716

.116

.616

.116

.416

.917

.4H

I PR

236

254

268

280

265

285

301

314

301

324

342

357

343

369

390

407

386

415

439

457

426

459

485

505

LO P

R11

512

213

314

212

112

914

115

012

613

414

615

613

214

115

416

313

914

716

117

114

315

216

617

7

1770

MBh

59.2

60.4

63.2

67.4

57.8

59.0

61.7

65.9

56.5

57.6

60.3

64.3

55.1

56.1

58.8

62.7

52.3

53.3

55.9

59.6

48.5

49.4

51.7

55.2

S/T

0.91

0.87

0.79

0.64

0.94

0.91

0.82

0.66

0.96

0.93

0.84

0.68

0.99

0.96

0.87

0.70

1.00

0.99

0.90

0.73

1.00

1.00

0.91

0.73

Del

ta T

2827

2622

2828

2623

2828

2623

2828

2623

2728

2623

2526

2421

KW3.

763.

843.

954.

074.

044.

124.

254.

384.

284.

374.

514.

654.

504.

594.

744.

894.

684.

784.

935.

094.

844.

945.

105.

27AM

PS12

.012

.312

.612

.912

.813

.013

.413

.813

.713

.914

.314

.714

.414

.715

.115

.615

.215

.515

.916

.415

.916

.216

.717

.2H

I PR

232

250

264

275

260

280

296

309

296

319

336

351

337

363

383

400

379

408

431

450

419

451

476

497

LO P

R11

312

013

113

911

912

713

814

712

413

214

415

313

013

815

116

113

614

515

816

814

115

016

417

4

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 17: DTH Commercial

SS-DTH3 www.daikinac.com 17

Expanded Cooling Data — 5 Tons (3-Phase Models) (cont.)

Out

door

Am

bien

t Te

mpe

ratu

re65

7585

9510

511

5En

teri

ng In

door

Wet

Bul

b Te

mpe

ratu

reID

BAi

rflo

w59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

2244

MBh

58.8

60.9

66.8

-57

.459

.565

.2-

56.1

58.1

63.7

-54

.756

.762

.1-

52.0

53.9

59.0

-48

.149

.954

.7-

S/T

0.75

0.63

0.44

-0.

780.

650.

45-

0.80

0.67

0.46

-0.

830.

690.

48-

0.86

0.72

0.50

-0.

860.

720.

50-

Del

ta T

1816

12-

1816

12-

1816

12-

1916

12-

1816

12-

1715

11-

KW3.

753.

833.

94-

4.03

4.11

4.24

-4.

274.

364.

50-

4.49

4.58

4.73

-4.

674.

774.

92-

4.83

4.93

5.09

-AM

PS12

.012

.212

.5-

12.8

13.0

13.3

-13

.613

.914

.3-

14.4

14.7

15.1

-15

.115

.415

.8-

15.9

16.2

16.6

-H

I PR

231

249

263

-26

027

929

5-

295

318

335

-33

636

238

2-

378

407

430

-41

845

047

5-

LO P

R11

211

913

0-

119

126

138

-12

313

114

3-

130

138

150

-13

614

415

8-

140

149

163

-

1961

MBh

57.1

59.2

64.8

-55

.857

.863

.3-

54.4

56.4

61.8

-53

.155

.060

.3-

50.4

52.3

57.3

-46

.748

.453

.1-

S/T

0.72

0.60

0.42

-0.

740.

620.

43-

0.76

0.64

0.44

-0.

790.

660.

46-

0.82

0.68

0.47

-0.

820.

690.

48-

Del

ta T

1917

13-

1917

13-

1917

13-

2017

13-

1917

13-

1816

12-

KW3.

723.

803.

91-

4.00

4.08

4.20

-4.

244.

334.

46-

4.45

4.54

4.69

-4.

634.

734.

88-

4.79

4.89

5.05

-AM

PS11

.912

.112

.5-

12.7

12.9

13.2

-13

.513

.814

.2-

14.3

14.5

14.9

-15

.015

.315

.7-

15.7

16.1

16.5

-H

I PR

229

246

260

-25

727

729

2-

292

315

332

-33

335

837

8-

374

403

426

-41

444

547

0-

LO P

R11

111

812

9-

117

125

136

-12

213

014

2-

128

136

149

-13

414

315

6-

139

148

161

-

1770

MBh

56.2

58.3

63.9

-54

.956

.962

.4-

53.6

55.6

60.9

-52

.354

.259

.4-

49.7

51.5

56.4

-46

.047

.752

.3-

S/T

0.69

0.58

0.40

-0.

720.

600.

42-

0.74

0.61

0.43

-0.

760.

630.

44-

0.79

0.66

0.46

-0.

800.

660.

46-

Del

ta T

2018

13-

2018

13-

2118

13-

2118

14-

2018

13-

1916

12-

KW3.

683.

753.

86-

3.94

4.02

4.15

-4.

184.

274.

40-

4.39

4.48

4.62

-4.

574.

664.

81-

4.72

4.82

4.98

-AM

PS11

.812

.012

.3-

12.5

12.8

13.1

-13

.413

.614

.0-

14.1

14.4

14.7

-14

.815

.115

.5-

15.5

15.8

16.3

-H

I PR

225

242

256

-25

327

228

7-

287

309

326

-32

735

237

2-

368

396

418

-40

743

846

2-

LO P

R10

911

612

7-

115

123

134

-12

012

813

9-

126

134

146

-13

214

115

3-

137

145

159

-

75

2244

MBh

59.8

61.6

66.6

71.5

58.4

60.1

65.1

69.9

57.0

58.7

63.5

68.2

55.6

57.3

62.0

66.5

52.8

54.4

58.9

63.2

48.9

50.4

54.5

58.5

S/T

0.86

0.77

0.58

0.37

0.89

0.79

0.60

0.39

0.91

0.81

0.62

0.40

0.94

0.84

0.64

0.41

0.97

0.87

0.66

0.42

0.98

0.88

0.67

0.43

Del

ta T

2119

1611

2120

1611

2120

1611

2120

1611

2119

1611

2018

1510

KW3.

783.

863.

974.

104.

064.

144.

274.

414.

304.

404.

534.

684.

524.

624.

764.

924.

714.

814.

965.

124.

864.

975.

135.

30AM

PS12

.112

.312

.613

.012

.913

.113

.413

.813

.714

.014

.414

.814

.514

.815

.215

.615

.215

.516

.016

.516

.016

.316

.817

.3H

I PR

234

251

266

277

262

282

298

311

298

321

339

353

340

366

386

403

382

411

434

453

422

454

480

500

LO P

R11

312

113

214

012

012

813

914

812

513

314

515

413

113

915

216

213

714

615

917

014

215

116

517

5

1961

MBh

58.1

59.8

64.7

69.4

56.7

58.4

63.2

67.8

55.4

57.0

61.7

66.2

54.0

55.6

60.2

64.6

51.3

52.8

57.2

61.4

47.5

48.9

53.0

56.8

S/T

0.82

0.73

0.55

0.36

0.85

0.76

0.57

0.37

0.87

0.78

0.59

0.38

0.90

0.80

0.61

0.39

0.93

0.83

0.63

0.40

0.94

0.84

0.63

0.41

Del

ta T

2220

1712

2221

1712

2321

1712

2321

1712

2221

1712

2119

1611

KW3.

753.

833.

944.

064.

034.

114.

244.

374.

274.

364.

504.

644.

494.

584.

734.

884.

674.

774.

925.

084.

834.

935.

095.

26AM

PS12

.012

.212

.512

.912

.813

.013

.313

.713

.613

.914

.314

.714

.414

.715

.115

.515

.115

.415

.916

.315

.916

.216

.617

.2H

I PR

231

249

263

274

260

279

295

308

295

318

336

350

336

362

382

399

378

407

430

448

418

450

475

495

LO P

R11

212

013

013

911

912

613

814

712

313

114

315

313

013

815

016

013

614

415

816

814

014

916

317

4

1770

MBh

57.2

58.9

63.7

68.4

55.8

57.5

62.2

66.8

54.5

56.1

60.8

65.2

53.2

54.8

59.3

63.6

50.5

52.0

56.3

60.4

46.8

48.2

52.2

56.0

S/T

0.79

0.70

0.53

0.34

0.82

0.73

0.55

0.36

0.84

0.75

0.57

0.36

0.86

0.77

0.58

0.38

0.90

0.80

0.61

0.39

0.90

0.81

0.61

0.39

Del

ta T

2322

1812

2422

1812

2422

1812

2422

1812

2422

1812

2220

1711

KW3.

703.

783.

894.

013.

974.

064.

184.

314.

214.

304.

444.

584.

424.

524.

664.

814.

604.

704.

855.

014.

764.

865.

025.

18AM

PS11

.912

.112

.412

.712

.612

.813

.213

.613

.513

.714

.114

.514

.214

.514

.915

.314

.915

.215

.616

.115

.716

.016

.416

.9H

I PR

227

245

258

270

255

275

290

302

290

312

330

344

331

356

376

392

372

400

423

441

411

442

467

487

LO P

R11

011

712

813

711

712

413

514

412

112

914

115

012

713

514

815

813

314

215

516

513

814

716

017

1ID

B =

Ente

ring

Indo

or D

ry B

ulb

Tem

pera

ture

Shad

ed a

rea

refle

cts

ACCA

(TVA

) con

ditio

nskW

= T

otal

sys

tem

pow

erH

igh

& lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d &

suc

tion

serv

ice

port

s.Am

ps: U

nit a

mps

(com

p.+

evap

orat

or +

con

dens

er fa

n m

otor

s)D

esig

n Su

bcoo

ling,

12±

3 °F

@ th

e liq

uid

acce

ss fi

tting

con

necti

on A

HRI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

±3 °F

@ th

e co

mpr

esso

r suc

tion

acce

ss fi

tting

con

necti

on.

Out

door

Am

bien

t Tem

pera

ture

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Airfl

ow59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

2244

MBh

60.9

62.2

66.4

71.0

59.4

60.7

64.9

69.4

58.0

59.3

63.3

67.7

56.6

57.8

61.8

66.1

53.8

55.0

58.7

62.8

49.8

50.9

54.4

58.1

S/T

0.94

0.88

0.72

0.54

1.00

0.91

0.74

0.56

1.00

0.94

0.76

0.57

1.00

0.97

0.79

0.59

1.00

1.00

0.82

0.61

1.00

1.00

0.82

0.62

Del

ta T

2322

2016

2423

2016

2423

2016

2323

2016

2223

2016

2021

1815

KW3.

813.

894.

004.

134.

094.

184.

304.

444.

344.

434.

574.

724.

564.

664.

804.

964.

744.

855.

005.

174.

905.

015.

175.

34AM

PS12

.212

.412

.713

.112

.913

.213

.513

.913

.814

.114

.514

.914

.614

.915

.315

.815

.415

.716

.116

.616

.116

.416

.917

.4H

I PR

236

254

268

280

265

285

301

314

301

324

342

357

343

369

390

407

386

415

439

457

426

459

485

505

LO P

R11

512

213

314

212

112

914

115

012

613

414

615

613

214

115

416

313

914

716

117

114

315

216

617

7

1961

MBh

59.1

60.4

64.5

69.0

57.7

59.0

63.0

67.3

56.3

57.6

61.5

65.7

55.0

56.2

60.0

64.1

52.2

53.4

57.0

60.9

48.4

49.4

52.8

56.4

S/T

0.90

0.84

0.68

0.51

0.93

0.87

0.71

0.53

0.95

0.89

0.73

0.54

0.98

0.92

0.75

0.56

1.00

0.96

0.78

0.58

1.00

0.96

0.78

0.59

Del

ta T

2524

2117

2524

2117

2524

2117

2524

2117

2424

2117

2322

1916

KW3.

783.

863.

974.

104.

064.

144.

274.

414.

304.

404.

534.

684.

524.

624.

774.

924.

714.

814.

965.

124.

874.

975.

135.

30AM

PS12

.112

.312

.613

.012

.913

.113

.413

.813

.714

.014

.414

.814

.514

.815

.215

.615

.215

.516

.016

.516

.016

.316

.817

.3H

I PR

234

251

266

277

262

282

298

311

298

321

339

353

340

366

386

403

382

411

434

453

422

454

480

500

LO P

R11

312

113

214

012

012

813

914

812

513

314

515

413

113

915

216

213

714

615

917

014

215

116

517

5

1770

MBh

58.2

59.5

63.5

67.9

56.8

58.1

62.1

66.3

55.5

56.7

60.6

64.8

54.1

55.3

59.1

63.2

51.4

52.6

56.1

60.0

47.6

48.7

52.0

55.6

S/T

0.86

0.81

0.66

0.49

0.90

0.84

0.68

0.51

0.92

0.86

0.70

0.52

0.95

0.89

0.72

0.54

0.98

0.92

0.75

0.56

0.99

0.93

0.76

0.57

Del

ta T

2625

2217

2625

2218

2625

2218

2726

2218

2625

2217

2524

2016

KW3.

733.

813.

924.

044.

014.

094.

214.

354.

254.

344.

474.

614.

464.

564.

704.

854.

644.

744.

895.

054.

804.

905.

065.

23AM

PS12

.012

.212

.512

.812

.712

.913

.313

.713

.613

.814

.214

.614

.314

.615

.015

.415

.015

.315

.816

.315

.816

.116

.517

.1H

I PR

230

247

261

272

258

277

293

306

293

315

333

347

334

359

379

396

376

404

427

445

415

447

472

492

LO P

R11

211

913

013

811

812

513

714

612

213

014

215

112

913

714

915

913

514

315

716

713

914

816

217

2

85

2244

MBh

61.9

63.1

66.1

70.5

60.5

61.6

64.6

68.9

59.0

60.2

63.0

67.2

57.6

58.7

61.5

65.6

54.7

55.8

58.4

62.3

50.7

51.7

54.1

57.7

S/T

0.98

0.95

0.86

0.70

1.00

0.98

0.89

0.72

1.00

1.00

0.91

0.74

1.00

1.00

0.94

0.76

1.00

1.00

0.98

0.79

1.00

1.00

0.98

0.80

Del

ta T

2525

2320

2525

2420

2425

2420

2424

2421

2223

2320

2121

2219

KW3.

843.

924.

044.

164.

124.

214.

344.

484.

374.

474.

614.

754.

594.

694.

845.

004.

784.

895.

045.

214.

945.

055.

225.

39AM

PS12

.312

.512

.813

.213

.013

.313

.614

.013

.914

.214

.615

.014

.715

.015

.415

.915

.515

.816

.216

.716

.216

.617

.017

.6H

I PR

238

257

271

283

268

288

304

317

304

327

346

361

347

373

394

411

390

420

443

462

431

464

489

510

LO P

R11

612

313

414

312

213

014

215

112

713

514

815

713

414

215

516

514

014

916

217

314

515

416

817

9

1961

MBh

60.1

61.3

64.2

68.5

58.7

59.9

62.7

66.9

57.3

58.4

61.2

65.3

55.9

57.0

59.7

63.7

53.1

54.2

56.7

60.5

49.2

50.2

52.5

56.0

S/T

0.94

0.91

0.82

0.66

0.97

0.94

0.85

0.69

1.00

0.96

0.87

0.71

1.00

0.99

0.90

0.73

1.00

1.00

0.93

0.76

1.00

1.00

0.94

0.76

Del

ta T

2626

2521

2726

2522

2726

2522

2627

2522

2525

2521

2324

2320

KW3.

813.

894.

004.

134.

094.

184.

304.

444.

344.

434.

574.

724.

564.

664.

804.

964.

744.

855.

005.

174.

905.

015.

175.

34AM

PS12

.212

.412

.713

.112

.913

.213

.513

.913

.814

.114

.514

.914

.614

.915

.315

.815

.415

.716

.116

.616

.116

.416

.917

.4H

I PR

236

254

268

280

265

285

301

314

301

324

342

357

343

369

390

407

386

415

439

457

426

459

485

505

LO P

R11

512

213

314

212

112

914

115

012

613

414

615

613

214

115

416

313

914

716

117

114

315

216

617

7

1770

MBh

59.2

60.4

63.2

67.4

57.8

59.0

61.7

65.9

56.5

57.6

60.3

64.3

55.1

56.1

58.8

62.7

52.3

53.3

55.9

59.6

48.5

49.4

51.7

55.2

S/T

0.91

0.87

0.79

0.64

0.94

0.91

0.82

0.66

0.96

0.93

0.84

0.68

0.99

0.96

0.87

0.70

1.00

0.99

0.90

0.73

1.00

1.00

0.91

0.73

Del

ta T

2827

2622

2828

2623

2828

2623

2828

2623

2728

2623

2526

2421

KW3.

763.

843.

954.

074.

044.

124.

254.

384.

284.

374.

514.

654.

504.

594.

744.

894.

684.

784.

935.

094.

844.

945.

105.

27AM

PS12

.012

.312

.612

.912

.813

.013

.413

.813

.713

.914

.314

.714

.414

.715

.115

.615

.215

.515

.916

.415

.916

.216

.717

.2H

I PR

232

250

264

275

260

280

296

309

296

319

336

351

337

363

383

400

379

408

431

450

419

451

476

497

LO P

R11

312

013

113

911

912

713

814

712

413

214

415

313

013

815

116

113

614

515

816

814

115

016

417

4

IDB

= En

terin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h &

low

pre

ssur

es a

re m

easu

red

at th

e liq

uid

& s

uctio

n se

rvic

e po

rts.

Amps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

2±3

°F @

the

liqui

d ac

cess

fitti

ng c

onne

ction

AH

RI 9

5 te

st c

ondi

tions

. Des

ign

Supe

rhea

t 8±3

°F @

the

com

pres

sor s

uctio

n ac

cess

fitti

ng c

onne

ction

.

Page 18: DTH Commercial

18 www.daikinac.com SS-DTH3

Airflow Data — 3 Tons

Downshot Horizontal

SPEEDTAP

ESPin w.c. CFM Amps Watts RPM SPEED

TAPESP

in w.c. CFM Amps Watts RPM

T1

0.1 966 0.5 108 657

T1

0.1 1018 0.47 101 6150.2 850 0.52 115 710 0.2 969 0.49 109 6530.3 773 0.55 122 763 0.3 881 0.53 117 7120.4 678 0.59 130 819 0.4 818 0.55 125 7680.5 593 0.62 141 875 0.5 732 0.59 135 8330.6 --- --- --- --- 0.6 658 0.63 142 8900.7 --- --- --- --- 0.7 616 0.65 148 9380.8 --- --- --- --- 0.8 --- --- --- ---0.9 --- --- --- --- 0.9 --- --- --- ---

T2

0.1 1057 0.6 134 693

T2

0.1 1128 0.56 126 6450.2 956 0.62 140 740 0.2 1070 0.59 132 6920.3 868 0.66 144 787 0.3 994 0.62 138 7270.4 788 0.69 156 839 0.4 915 0.66 149 7910.5 700 0.73 166 898 0.5 839 0.69 156 8380.6 618 0.76 174 946 0.6 776 0.73 169 9090.7 --- --- --- --- 0.7 698 0.77 179 9630.8 --- --- --- --- 0.8 649 0.8 183 10030.9 --- --- --- --- 0.9 --- --- --- ---

T3

0.1 1234 0.86 199 784

T3

0.1 1293 0.81 186 7330.2 1146 0.89 206 822 0.2 1252 0.84 193 7650.3 1068 0.92 213 863 0.3 1198 0.87 204 8030.4 977 0.96 221 910 0.4 1130 0.91 212 8440.5 911 1.0 232 949 0.5 1075 0.94 218 8860.6 842 1.04 245 998 0.6 1015 0.98 230 9300.7 776 1.08 253 1031 0.7 941 1.02 242 9840.8 703 1.11 263 1082 0.8 870 1.08 253 10450.9 682 1.13 266 1107 0.9 817 1.11 262 1080

T4

0.1 1363 1.03 242 822

T4

0.1 1404 0.99 232 7890.2 1253 1.09 251 874 0.2 1367 1.02 240 8170.3 1176 1.12 260 910 0.3 1334 1.05 244 8450.4 1110 1.15 270 940 0.4 1265 1.09 257 8820.5 1034 1.19 279 981 0.5 1207 1.13 265 9220.6 966 1.23 290 1028 0.6 1153 1.17 272 9580.7 899 1.27 301 1074 0.7 1090 1.21 283 10050.8 836 1.33 312 1117 0.8 1029 1.25 299 10520.9 778 1.35 319 1146 0.9 947 1.31 312 1111

T5

0.1 1413 1.14 268 849

T5

0.1 1457 1.08 254 8050.2 1299 1.18 275 899 0.2 1413 1.12 266 8390.3 1233 1.23 259 933 0.3 1359 1.16 273 8700.4 1166 1.26 296 963 0.4 1307 1.2 285 9110.5 1096 1.3 307 1000 0.5 1253 1.23 291 9400.6 1026 1.34 318 1040 0.6 1197 1.28 304 9780.7 960 1.39 330 1052 0.7 1138 1.31 310 10170.8 889 1.44 340 1132 0.8 1082 1.36 322 10590.9 835 1.47 347 1169 0.9 1029 1.41 335 1105

Notes:Table represent dry coil without filter, to compensate for filter add 0.08" to measured E.S.P.. SCFM correction for wet coil = 4%. Models are shipped from the factory with speed tap set on T4.

Page 19: DTH Commercial

SS-DTH3 www.daikinac.com 19

Airflow Data — 4 Tons

Downshot Horizontal

SPEEDTAP

ESPin w.c. CFM Amps Watts RPM SPEED

TAPESP

in w.c. CFM Amps Watts RPM

T1

0.1 1286 0.82 187 667

T1

0.1 1346 0.77 176 6220.2 1205 0.86 198 704 0.2 1286 0.8 186 6570.3 1139 0.8 205 731 0.3 1211 0.84 198 6980.4 1052 0.92 212 764 0.4 1144 0.88 204 7300.5 982 0.95 215 790 0.5 1068 0.92 214 7680.6 911 0.97 224 814 0.6 996 0.95 222 7980.7 840 1 230 837 0.7 923 0.98 229 8290.8 779 1.02 235 855 0.8 839 1.01 235 8570.9 717 1.04 242 879 0.9 777 1.04 242 881

T2

0.1 1470 1.09 251 726

T2

0.1 1534 1.01 234 6810.2 1399 1.12 260 758 0.2 1482 1.05 246 7100.3 1315 1.16 271 790 0.3 1412 1.09 256 7450.4 1253 1.19 281 814 0.4 1352 1.13 263 7740.5 1180 1.22 287 842 0.5 1286 1.17 272 8060.6 1110 1.26 292 867 0.6 1216 1.19 281 8390.7 1042 1.29 300 891 0.7 1147 1.24 289 8680.8 973 1.32 308 914 0.8 1077 1.27 299 8920.9 916 1.34 314 933 0.9 1002 1.31 309 922

T3

0.1 1747 1.75 413 855

T3

0.1 1515 1.61 382 7870.2 1668 1.8 414 884 0.2 1762 1.65 392 8090.3 1609 1.84 436 908 0.3 1697 1.69 399 8350.4 1557 1.88 442 931 0.4 1651 1.74 416 8630.5 1489 1.92 453 957 0.5 1598 1.79 423 8920.6 1419 1.97 476 984 0.6 1533 1.85 438 9220.7 1377 2 472 1002 0.7 1464 1.89 447 9510.8 1311 2.03 479 1022 0.8 1417 1.94 458 9750.9 1256 2.07 488 1044 0.9 1361 1.97 475 999

T4

0.1 1879 2.11 504 908

T4

0.1 1941 1.96 464 8340.2 1799 2.16 512 935 0.2 1888 1.99 471 8530.3 1730 2.2 525 955 0.3 1847 2.04 491 8760.4 1677 2.26 539 981 0.4 1790 2.09 502 9060.5 1630 2.31 547 1006 0.5 1742 2.14 509 9280.6 1558 2.35 557 1032 0.6 1682 2.19 537 9570.7 1508 2.38 553 1049 0.7 1620 2.26 5337 9870.8 1443 2.43 588 1072 0.8 1576 2.28 547 10100.9 1389 2.48 585 1091 0.9 1521 2.33 556 1034

T5

0.1 1903 2.28 542 931

T5

0.1 1994 2.09 497 8450.2 1838 2.31 561 952 0.2 1946 2.16 511 8760.3 1785 2.38 571 977 0.3 1893 2.15 518 8960.4 1723 2.41 574 1002 0.4 1865 2.28 536 9230.5 1666 2.46 585 1020 0.5 1795 2.26 548 3510.6 1612 2.51 596 1048 0.6 1741 2.39 555 3760.7 1547 2.56 611 1067 0.7 1681 2.38 572 9990.8 1505 2.59 607 1083 0.8 1630 2.47 597 10230.9 1445 2.63 613 1109 0.9 1576 2.47 595 1046

Notes:Table represent dry coil without filter, to compensate for filter add 0.08” to measured E.S.P.. SCFM correction for wet coil = 4%. Models are shipped from the factory with speed tap set on T4.

Page 20: DTH Commercial

20 www.daikinac.com SS-DTH3

Airflow Data — 5 Tons

Downshot Horizontal

SPEEDTAP

ESPin w.c. CFM Amps Watts RPM SPEED

TAPESP

in w.c. CFM Amps Watts RPM

T1

0.1 1334 1.65 180 627

T1

0.1 1355 1.57 174 5990.2 1286 1.75 192 665 0.2 1281 1.66 182 6510.3 1212 1.83 202 715 0.3 1235 1.76 196 6930.4 1144 1.94 216 759 0.4 1168 1.81 202 7260.5 1077 1.99 222 792 0.5 1118 1.94 218 7750.6 1039 2.10 238 830 0.6 1049 2.03 232 8190.7 953 2.17 248 874 0.7 982 2.10 240 8580.8 904 2.27 258 913 0.8 922 2.14 246 8850.9 825 2.30 266 940 0.9 871 2.25 260 927

T2

0.1 1512 2.12 240 682

T2

0.1 1544 2.04 234 6600.2 1469 2.24 254 720 0.2 1490 2.17 250 7040.3 1397 2.31 264 759 0.3 1427 2.25 260 7420.4 1333 2.44 282 803 0.4 1370 2.35 276 7810.5 1285 2.54 296 836 0.5 1319 2.42 282 8090.6 1221 2.59 304 874 0.6 1274 2.52 296 8490.7 1173 2.72 322 913 0.7 1210 2.62 316 8910.8 1118 2.77 328 946 0.8 1137 2.73 326 9350.9 1049 2.90 344 984 0.9 1106 2.77 336 957

T3

0.1 2053 4.27 540 869

T3

0.1 2099 4.13 516 8250.2 2014 4.39 558 896 0.2 2068 4.25 536 8520.3 1999 4.60 576 929 0.3 2029 4.37 552 8850.4 1947 4.68 588 957 0.4 1971 4.48 568 9130.5 1897 4.79 608 989 0.5 1911 4.61 586 9500.6 1857 4.87 620 1012 0.6 1876 4.73 604 9730.7 1763 4.99 640 1050 0.7 1821 4.86 622 10120.8 1741 5.06 650 1072 0.8 1792 4.91 630 10280.9 1669 5.19 668 1105 0.9 1740 5.03 648 1067

T4

0.1 2137 4.95 634 913

T4

0.1 2233 4.76 608 8630.2 2093 5.07 652 940 0.2 2168 4.91 628 8960.3 2095 5.19 670 962 0.3 2125 5.02 640 9240.4 2026 5.28 682 990 0.4 2070 5.14 660 9510.5 1980 5.40 698 1018 0.5 2050 5.27 678 9790.6 1961 5.49 720 1039 0.6 1980 5.41 696 10120.7 1914 5.58 732 1072 0.7 1954 5.47 704 10340.8 1845 5.70 742 1100 0.8 1893 5.60 724 10670.9 1766 5.69 740 1127 0.9 1852 5.70 736 1089

T5

0.1 2299 5.70 742 942

T5

0.1 2322 5.44 710 9040.2 2233 5.80 748 969 0.2 2294 5.55 726 9340.3 2217 5.90 768 990 0.3 2254 5.68 742 9580.4 2157 6.07 786 1018 0.4 2201 5.80 766 9900.5 2131 6.12 804 1045 0.5 2147 5.93 782 10170.6 2060 6.21 816 1073 0.6 2117 6.01 788 10390.7 2015 6.30 820 1095 0.7 2081 6.12 808 10600.8 1940 6.27 816 1111 0.8 2017 6.22 822 10940.9 1862 6.13 790 1128 0.9 1932 6.10 804 1111

Notes:Table represent dry coil without filter, to compensate for filter add 0.08” to measured E.S.P.. SCFM correction for wet coil = 4%. Models are shipped from the factory with speed tap set on T4.

Airflow Pressure Drop of Downflow Economizer for 3 to 6 Ton Rooftop Units (100% Return Air)SCFM 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800

in. WG 0.02 0.04 0.05 0.07 0.09 0.12 0.14 0.17 0.21 0.24 0.28

Page 21: DTH Commercial

SS-DTH3 www.daikinac.com 21

DTH036***1D***

Outdoor Ambient Temperature

65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10

MBh 43.7 41.4 39.0 36.4 34.8 33.7 31.3 28.9 22.4 20.7 19.1 18.0 17.3 15.6 13.8 12.0 10.3 8.4

T/R 33.8 32.0 30.1 28.1 26.9 26.0 24.2 22.3 17.3 16.0 14.7 13.9 13.4 12.0 10.6 9.3 7.9 6.5

KW 2.73 2.67 2.62 2.58 2.55 2.53 2.46 2.40 2.35 2.30 2.26 2.20 2.16 2.11 2.08 2.04 2.01 1.97

COP 4.69 4.54 4.35 4.13 3.99 3.90 3.73 3.52 2.79 2.63 2.47 2.39 2.35 2.16 1.94 1.72 1.49 1.25

EER 16.0 15.5 14.9 14.1 13.6 13.3 12.7 12.0 9.5 9.0 8.4 8.2 8.0 7.4 6.6 5.9 5.1 4.3

HI PR 383 368 353 338 330 324 311 299 286 273 262 256 251 242 233 223 215 208

LO PR 146 135 127 116 110 106 97 87 78 70 61 57 55 47 40 34 30 23

DTH036***3D***

Outdoor Ambient Temperature

65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10

MBh 41.2 39.0 36.7 34.3 32.8 31.8 29.5 27.2 22.4 20.7 19.1 18.0 17.3 15.6 13.8 12.0 10.3 8.4

T/R 31.8 30.1 28.3 26.5 25.3 24.5 22.8 21.0 17.3 16.0 14.7 13.9 13.4 12.0 10.6 9.3 7.9 6.5

KW 3.03 2.95 2.85 2.76 2.67 2.60 2.54 2.48 2.42 2.42 2.42 2.41 2.34 2.26 2.19 2.11 2.06 1.96

COP 3.99 3.88 3.78 3.65 3.60 3.58 3.41 3.22 2.72 2.51 2.31 2.30 2.17 2.02 1.84 1.67 1.46 1.26

EER 13.6 13.2 12.9 12.4 12.3 12.2 11.6 11.0 9.3 8.6 7.9 7.5 7.4 6.9 6.3 5.7 5.0 4.3

HI PR 402 385 371 354 346 339 326 313 300 286 275 268 264 254 244 234 226 218

LO PR 139 129 121 111 105 101 93 83 75 67 59 54 53 44 38 32 28 22

DTH048***1D

Outdoor Ambient Temperature

65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10

MBh 55.9 53.0 49.8 46.6 44.5 43.1 40.1 36.9 29.9 27.6 25.4 24.0 23.1 20.7 18.4 16.0 13.7 11.2

T/R 32.4 30.6 28.8 27.0 25.8 25.0 23.2 21.4 17.3 16.0 14.7 13.9 13.4 12.0 10.6 9.3 7.9 6.5

KW 3.67 3.61 3.56 3.50 3.43 3.41 3.34 3.26 3.20 3.11 3.03 2.93 2.86 2.79 2.71 2.65 2.59 2.52

COP 4.46 4.29 4.10 3.90 3.80 3.70 3.51 3.32 2.73 2.60 2.45 2.40 2.36 2.18 1.99 1.77 1.55 1.30

EER 15.2 14.7 14.0 13.3 13.0 12.6 12.0 11.3 9.3 8.9 8.4 8.2 8.1 7.4 6.8 6.0 5.3 4.4

HI PR 383 368 353 338 330 324 311 299 286 273 262 256 251 242 233 223 215 208

LO PR 133 123 115 106 100 96 89 79 71 64 56 52 50 42 37 31 27 21

DTH048***3D

Outdoor Ambient Temperature

65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10

MBh 55.3 52.4 49.3 46.1 44.0 42.6 39.6 36.5 29.4 27.1 25.0 23.6 22.7 20.4 18.1 15.8 13.5 11.0

T/R 32.0 30.3 28.5 26.7 25.5 24.7 22.9 21.1 17.0 15.7 14.5 13.7 13.2 11.8 10.5 9.1 7.8 6.4

KW 3.67 3.67 3.57 3.48 3.39 3.24 3.18 3.12 3.06 2.97 2.91 2.84 2.77 2.69 2.62 2.54 2.49 2.39

COP 4.42 4.18 4.04 3.88 3.80 3.86 3.65 3.43 2.82 2.68 2.52 2.43 2.40 2.22 2.02 1.82 1.58 1.35

EER 15.1 14.3 13.8 13.2 13.0 13.2 12.5 11.7 9.6 9.1 8.6 8.3 8.2 7.6 6.9 6.2 5.4 4.6

HI PR 400 384 369 353 345 338 325 312 299 285 274 267 263 253 243 233 225 217

LO PR 136 126 118 108 103 99 91 81 73 65 57 53 51 43 37 32 28 22

Expanded Heating Data

Page 22: DTH Commercial

22 www.daikinac.com SS-DTH3

DTH060***3D

Outdoor Ambient Temperature

65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10

MBh 69.1 65.5 61.6 57.6 55.0 53.3 49.5 45.7 38.4 35.4 32.6 30.8 29.7 26.6 23.6 20.6 17.6 14.4

T/R 32.0 30.3 28.5 26.7 25.5 24.7 22.9 21.1 17.8 16.4 15.1 14.3 13.7 12.3 10.9 9.5 8.1 6.7

KW 4.84 4.76 4.66 4.57 4.48 4.41 4.35 4.29 4.23 4.14 4.10 4.01 3.94 3.86 3.79 3.71 3.66 3.56

COP 4.19 4.03 3.87 3.69 3.59 3.54 3.33 3.12 2.66 2.51 2.46 2.40 2.31 2.22 2.13 2.04 1.95 1.86

EER 14.3 13.8 13.2 12.6 12.3 12.1 11.4 10.6 9.1 8.6 8.0 7.7 7.5 6.9 6.2 5.5 4.8 4.0

HI PR 404 388 373 356 348 341 328 315 302 288 277 270 265 255 245 235 227 219

LO PR 130 121 113 104 98 94 87 77 70 62 55 51 49 41 36 30 26 21

Above information is for 2150 CFM & 70º indoor dry bulb; instantaneous capacity listed. kW = Total system powerHigh pressure measured at liquid line access fitting. Amps: Unit Amps (comp+evap motor+condenser fan motor)Low pressure measured at compressor suction access fitting.

DTH060***1D

Outdoor Ambient Temperature

65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10

MBh 69.8 66.0 62.2 58.1 55.5 53.8 50.0 46.1 38.9 35.9 33.0 31.2 30.0 27.0 23.9 20.8 17.8 14.6

T/R 40.4 38.2 36.0 33.6 32.1 31.1 28.9 26.7 22.5 20.8 19.1 18.1 17.4 15.6 13.8 12.1 10.3 8.4

KW 4.63 4.55 4.45 4.36 4.27 4.20 4.14 4.08 4.02 3.93 3.87 3.80 3.73 3.65 3.58 3.50 3.45 3.35

COP 4.41 4.25 4.09 3.90 3.80 3.75 3.53 3.30 2.83 2.67 2.50 2.40 2.36 2.16 1.95 1.74 1.51 1.27

EER 15.1 14.5 14.0 13.3 13.0 12.8 12.1 11.3 9.7 9.1 8.5 8.2 8.1 7.4 6.7 6.0 5.2 4.3

HI PR 407 390 375 358 350 343 330 317 303 290 278 272 267 257 247 237 228 220

LO PR 133 123 115 106 100 96 89 79 71 64 56 52 50 42 37 31 27 21

Expanded Heating Data (cont.)

Page 23: DTH Commercial

SS-DTH3 www.daikinac.com 23

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0 700600500400300200100

Air Velocity (FPM)

Resi

stan

ce (i

n. w

.g.)

2" Deep

Flanders Pre Pleat M13Air Velocity vs Resistance

(Test Size: 24" x 24" x 2" High Capacity)

High Efficiency MERV 13 Air Filter Option

Crankcase Heater, High Efficiency MERV 13 Air Filter Option

Crankcase Heater Selection TableZP/ZPS… Compressor Diameter Compressor Voltage Crankcase

Heater Watts230V 460V 575V16-31 5.5" 0163R00002S 0163R00031S 0163R00032S 4039-83 6.58/7.3" 0130L00017S 0130L00018S 0130L00019S 70

103-137 9.14” 0130L00020S 0130L00021S 0130L00022S 90

DC*,DT* & DS* Tonnage Compressor Voltage Crankcase Heater Watts230V 460V 575V

3 Ton 0163R00002S 0163R00031S 0163R00032S 40

4 Ton-5 Ton 0130L00017S 0130L00018S 0130L00019S 70

*Includes C,G&H models.

Tonnage: Filter Nominal Size: Part Number: Order QTY:

3 24 x 24 x 2 0160L00203 1

4 14 x 20 x 2 0160L00204 4

5 16 x 20 x 2 0160L00205 4

Page 24: DTH Commercial

24 www.daikinac.com SS-DTH3

Heat Kit Electrical Data

Model and Heat Kit Usage

RecommendedAirflow Range

DTH036***1D***

EHK1-10 1250-1350 CFM

EHK1-15 1250-1440 CFM

DTH036***3D***

EHK3-10 1250 - 1350 CFM

EHK3-15 1250-1440 CFMMinimum Airflow for Electric Heat

Heater Size Minimum CFM

10 kW 1250

15 kW 1400

18 kW 1575

20 kW 1850

kW Correction Factors

kW Correction Factor for 1- & 3-Phase UnitsSupply Voltage 240 230 220 210 208Correction Factor 1 0.92 0.84 0.77 0.75

Multiply rated kW by correction factor to get actual kW

Model and Heat Kit Usage

RecommendedAirflow Range

DTH048***1D***

EHK1-10 1400-1800 CFM

EHK1-15 1575-1800 CFM

EHK1-18 1575-1800 CFM

DTH048***3D***

EHK3-10 1400 - 1800 CFM

EHK3-15 1575 - 1800 CFM

EHK3-18 1575 - 1800 CFM

Model and Heat Kit Usage

RecommendedAirflow Range

DTH060***1D***EHK1-10 1750-2250 CFMEHK1-15 1750-2250 CFMEHK1-20 1850-2250 CFM

DTH060***3D***EHK3-10 1750 - 2250 CFMEHK3-15 1750 - 2250 CFMEHK3-20 1850 - 2250 CFM

Page 25: DTH Commercial

SS-DTH3 www.daikinac.com 25

Electrical Data

3 Tons

Model Number

Electrical Rating

Compressor Circuit 1

Compressor Circuit 2

Outdoor Fan Motor Indoor Fan Motor Optional Electric Heat

Optional Powered

Convienience Outlet

Power Supply

RLA LRA RLA LRA QTY HP FLA Type HP FLA Part # KW* FLA FLA MCA MOP

DTH036XXX1D 208/230-1-60 14.1 77.0 1 0.25 1.40 Standard - Direct Drive 0.50 3.90

- - - - 22.9 / 22.9 35 / 35EHK1-10 7.5 / 10.0 36.1 / 41.7 - 68.1 / 75.1 70 / 80EHK1-15 11.3 / 15.0 54.2 / 62.5 - 90.7 / 101 100 / 110

- - - 7.2 / 6.5 30.1 / 29.4 40 / 40EHK1-10 7.5 / 10.0 36.1 / 41.7 7.2 / 6.5 75.3 / 81.6 80 / 90EHK1-15 11.3 / 15.0 54.2 / 62.5 7.2 / 6.5 97.9 / 108 100 / 110

DTH036XXX3D 208/230-3-60 9.0 71.0 1 0.25 1.40 Standard - Direct Drive 0.50 3.90

- - - - 16.5 / 16.5 25 / 25EHK3-10 7.5 / 10.0 20.8 / 24.0 - 42.5 / 46.5 45 / 50EHK3-15 11.3 / 15.0 31.3 / 36.1 - 55.6 / 61.6 60 / 70

- - - 7.2 / 6.5 23.7 / 23.0 30 / 30EHK3-10 7.5 / 10.0 20.8 / 24.0 7.2 / 6.5 49.7 / 53.0 50 / 60EHK3-15 11.3 / 15.0 31.3 / 36.1 7.2 / 6.5 62.8 / 68.1 70 / 70

4 Tons

Model Number

Electrical Rating

Compressor Circuit 1

Compressor Circuit 2

Outdoor Fan Motor Indoor Fan Motor Optional Electric Heat

Optional Powered

Convienience Outlet

Power Supply

RLA LRA RLA LRA QTY HP FLA Type HP FLA Part # KW* FLA FLA MCA MOP

DTH048XXX1D 208/230-1-60 19.9 109.0 1 0.25 1.40 Standard - Direct Drive 1.00 6.90

- - - - 33.1 / 33.1 50 / 50EHK1-10 7.5 / 10.0 36.1 / 41.7 - 78.3 / 85.3 80 / 90EHK1-15 11.3 / 15.0 54.2 / 62.5 - 101 / 111 110 / 125EHK1-18 13.5 / 18.0 65.0 / 75.0 - 114 / 127 125 / 150

- - - 7.2 / 6.5 40.3 / 39.6 60 / 50EHK1-10 7.5 / 10.0 36.1 / 41.7 7.2 / 6.5 85.5 / 91.8 90 / 100EHK1-15 11.3 / 15.0 54.2 / 62.5 7.2 / 6.5 108 / 118 110 / 125EHK1-18 13.5 / 18.0 65.0 / 75.0 7.2 / 6.5 122 / 133 125 / 150

DTH048XXX3D 208/230-3-60 13.1 83.1 1 0.25 1.40 Standard - Direct Drive 1.00 6.90

- - - - 24.7 / 24.7 35 / 35EHK3-10 7.5 / 10.0 20.8 / 24.0 - 50.7 / 54.7 60 / 60EHK3-15 11.3 / 15.0 31.3 / 36.1 - 63.9 / 69.9 70 / 70EHK3-18 13.5 / 18.0 37.5 / 43.3 - 71.6 / 78.9 80 / 80

- - - 7.2 / 6.5 31.9 / 31.2 45 / 40EHK3-10 7.5 / 10.0 20.8 / 24.0 7.2 / 6.5 57.9 / 61.2 60 / 70EHK3-15 11.3 / 15.0 31.3 / 36.1 7.2 / 6.5 71.1 / 76.4 80 / 80EHK3-18 13.5 / 18.0 37.5 / 43.3 7.2 / 6.5 78.8 / 85.4 80 / 90

5 Tons

Model Number

Electrical Rating

Compressor Circuit 1

Compressor Circuit 2

Outdoor Fan Motor Indoor Fan Motor Optional Electric Heat

Optional Powered

Convienience Outlet

Power Supply

RLA LRA RLA LRA QTY HP FLA Type HP FLA Part # KW* FLA FLA MCA MOP

DTH060XXX1D 208/230-1-60 25.0 134.0 1 0.25 2.00 Standard - Direct Drive 1.00 6.90

- - - - 40.2 / 40.2 60 / 60EHK1-10 7.5 / 10.0 36.1 / 41.7 - 85.3 / 92.3 100 / 100EHK1-15 11.3 / 15.0 54.2 / 62.5 - 108 / 118 110 / 125EHK1-20 13.5 / 18.0 72.2 / 83.3 - 130 / 144 150 / 150

- - - 7.2 / 6.5 47.4 / 46.7 70 / 70EHK1-10 7.5 / 10.0 36.1 / 41.7 7.2 / 6.5 92.5 / 98.8 100 / 110EHK1-15 11.3 / 15.0 54.2 / 62.5 7.2 / 6.5 115 / 125 125 / 125EHK1-20 13.5 / 18.0 72.2 / 83.3 7.2 / 6.5 138 / 151 150 / 175

DTH060XXX3D 208/230-3-60 15.9 110.0 1 0.33 2.30 Standard - Direct Drive 1.00 6.90

- - - - 29.1 / 29.1 45 / 45EHK3-10 7.5 / 10.0 20.8 / 24.0 - 55.1 / 59.1 60 / 60EHK3-15 11.3 / 15.0 31.3 / 36.1 - 68.2 / 74.2 70 / 80EHK3-20 13.5 / 18.0 41.6 / 48.0 - 81.1 / 89.1 90 / 90

- - - 7.2 / 6.5 36.3 / 35.6 50 / 50EHK3-10 7.5 / 10.0 20.8 / 24.0 7.2 / 6.5 62.3 / 65.6 70 / 70EHK3-15 11.3 / 15.0 31.3 / 36.1 7.2 / 6.5 75.4 / 80.7 80 / 90EHK3-20 13.5 / 18.0 41.6 / 48.0 7.2 / 6.5 88.3 / 95.6 90 / 100

* Electric Heater kW rating: Rated at 240v for 208-230v units; 480v for 460v units

Page 26: DTH Commercial

26 www.daikinac.com SS-DTH3

Dimensions

11.2

65

33.8

05

73.9

4548

.196

6.19

610

.060

12.0

00

7.16

517

.000

31.5

4011

.000

20.8

53

4.47

5

ALL

DIM

EN

SIO

NS

GIV

EN

AR

E IN

INC

HE

SA

LL D

IME

NS

ION

S A

ND

SP

EC

IFIC

AT

ION

S A

RE

SU

BJE

CT

TO

CH

AN

GE

WIT

HO

UT

NO

TIC

E

DT

*036

-060

***

3 T

HR

U 5

-TO

N C

OM

ME

RC

IAL

GA

S L

INE

EN

TR

AN

CE

CO

MB

US

TIO

N A

IR IN

LET

(G

AS

UN

ITS

)

FLU

E/V

EN

T O

UT

LET

FR

ON

T V

IEW

TO

P V

IEW

FO

RK

HO

LES

BO

TH

SID

ES

A

ND

BO

TH

EN

DS

CO

ND

EN

SA

TE

DR

AIN

OU

TLE

T

LIF

TIN

G S

HA

CK

LE

HO

LES

BO

TH

SID

ES

A

ND

EN

DS

SU

PP

LY A

IR D

UC

T

RE

TU

RN

AIR

DU

CT

RIG

HT

EN

D V

IEW

25.0

00

Page 27: DTH Commercial

SS-DTH3 www.daikinac.com 27

Dimensions (cont.)

7.984

"C"

"B"

10.37

2

5.872

8.555

11.00

0

17.00

0

6.192

23.44

2

48.31

2

20.90

5

5.104

12.00

0

19.47

0

5.558

25.00

0

74.06

1

"A"

LINE

WIR

E EN

TRAN

CE

TSTA

T W

IRE

ENTR

ANCE

LEFT

END

VIE

W

SUPP

LY A

IR D

UCT

COND

ENSA

TEDR

AIN

BOTT

OM E

XIT

RETU

RN A

IR D

UCT

BASE

PAN

VIE

W(V

IEW

ED F

ROM

TOP)

MODE

L TON

NAGE

S"A

""B

""C

"

3-TO

N CO

MMER

CIAL

GAS,

HT

PUMP

, AIR

CON

DITI

ONER

38.84

016

.555

26.05

5

4-TO

N CO

MMER

CIAL

GAS,

HT

PUMP

, AIR

CON

DITI

ONER

38

.840

16.55

526

.055

5-TO

N CO

MMER

CIAL

GAS,

HT

PUMP

, AIR

CON

DITI

ONER

42

.840

20.55

530

.055

DISC

ONNE

CTLO

CATI

ON

Page 28: DTH Commercial

28 www.daikinac.com SS-DTH3

Unit Clearances

3½” Dia.

47½”7½”

Power Thru the Curb

Electrical Entrance Locations

30¼”

12⅜”

Low-Voltage Entrance

(Remove Plug)High-Voltage Entrance

Corner & Center-of-Gravity Locations

Y

Compressor

Return

Evaporator Coil

Supply

CondenserCoil

X

Model X (IN) Y (IN) Shipping Weight (LBS)

Operating Weight (LBS)

Corner Weights (LBS.)

A B C D

DTH036XXXXDXXX 37.8 26.8 548 520 105 161 122 132DTH048XXXXDXXX 39.4 27.2 577 549 159 134 77 179DTH060XXXXDXXX 40 25.1 612 583 204 113 72 194

Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a clearance of 48" on all sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit Beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit’s fresh-air intake. 48"

48"

48"

48"

Page 29: DTH Commercial

SS-DTH3 www.daikinac.com 29

Roof Curb Installation — Rigging

Provisions for forks have been included in the unit base frame. No other fork locations are approved.• Unit must be lifted by the four lifting holes located at the base frame corners.• Lifting cables should be attached to the unit with shackles.• The distance between the crane hook and the top of the unit must not

be less than 60”.• Two spreader bars must span over the unit to prevent damage to the

cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Re-move wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit.

Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual.Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual.Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end.Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and return openings with duct.To assist in determining rigging requirements, unit weights are shown below.Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association.Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb.Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package.

• Determine sufficient structural support before locating and mounting the curb and package unit.• Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before

mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory.

• Contractor furnishes curb insulation, cant strips, flashing, and general roofing material.• Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members cannot penetrate

supply and return duct openings.Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended.See the manual shipped with the roof curb for assembly and installation instructions.

3-D View

14 x 20Supply Opening

31⅝ x 14Return Opening

70¾ 40¼

14

15/6

¾

14

1⅜

Insulated Panels

R/A

S/A20

14.625

40.25

70.75

37

67.5

1.625

3

3

14

14

31.625

20

32.8753

16.000

O 1.750

15.250

TYP.O.D.

I.D. O.D.

I.D.

Top View

Page 30: DTH Commercial

30 www.daikinac.com SS-DTH3

Wiring Diagram — 3 through 5 Tons (230V, Single-Phase Direct Drive)

BR

RD

W

Y

PU PURPLE

CONTROL

H

YL

OR

C

RD

0-RV

YL

6

OR ORANGE

S

R-PS1

TB14

L

Y

BL

O

3 6

O

BL

3

H

1

N

RD

WH

C

LOW VOLTAGE

RD

O

C

BK

BK

OPTIONALHIGH VOLTAGE

L2

CM

2

RCCF

GR

T1

G

L2

R

BL

YL

DC

PU

5

3

L

YL

WH

TB1

R

C

E

THERMOSTATFIELD WIRING

BL

RD

RD

OR

Y1

HPS

5

GR

FIELD WIRING

SEENOTE 7

G

YL/PK YELLOW WITH PINK STRIP

BR BROWN

SEE NOTE 2

BL/PK BLUE WITH PINK STRIP

R

BK

C

YL

YL

GND

C

CONTACTORCOMPRESSOR CONTACTOR RELAYCRANKCASE HEATERCRANKCASE HEATER SWITCHCONDENSER MOTORCOMPRESSORDEFROST CONTROLDEFROST THERMOSTATECONOMIZEREVAPORATOR MOTOREQUIPMENT GROUNDHIGH PRESSURE SWITCHHIGH VOLTAGE DEFROST RELAYLOW PRESSURE SWITCHLOW VOLTAGE DEFROST RELAYLOW VOLTAGE JUNCTION BOXFEMALE PLUG / CONNECTORREVERSING VALVE COILRUN CAPACITOR FORCOMPRESSOR AND FANTERMINAL BLOCK (24V SIGNAL)TRANSFORMER

G

COMPONENT LEGEND

BL/PK

YL

1

RD

BK

BL

GR

1

O

F

1

R

4

LPS

WH

Y RD

YL

BL

PS2

RVC

7T

PK PINK

COMP

BR

SEE UNIT RATING PLATE FOR TYPE AND SIZE

BL

BK

D2

T

A

T2

BK

YL

BL

HIGH VOLTAGE

GR

5

YL

3

TB1

RCCF

RD

CCCRCHCHSCMCOMPDCDFTECONEMGNDHPSHVDRLPSLVDRLVJBPLFRVCRCCF

TB1TR

C-RV

W

L1

C

BL

1

LOW VOLTAGE

BK

F

BL

G

PU

TB1

T1

L1

GR

CM

W

LVDR

G

GR

OC

208

R

PK

WH

W

CHS

4

BK BLACK

8

TR

WITH ECONOMIZER OPTION

1

5

DF1 2

BL BLUE

FACTORY WIRING

BK

O-RV W

208-240

WH WHITE

PU

RD

R

CH

LVJB

OR

YL YELLOW

C

PU

PU

YL

60

C

R-DFT

OR

Y

BK

PU

4

PU

STAT

RD

T1

3

PK

PU

EM

5

9

OR

CH

DFT

0

W1

SEENOTE 6

PLF1

RD RED

4

DFT

BR

BK

BK

CNT

Y1

TR

0

H

R

OGR

Y1

C

2

2

C

3

BR

SUPPLY VOLTAGE

WH

O

RD

Y1

BL

SEENOTE 7

BOX

GR

GR GREEN

RD

PU

GR

GR

240

C

/

T3

24V

OR

BL

CCR

WH

C

6

STAT

W

WH

PLF2

WH

C

EM

WH

W

Y2

SEE NOTE 5

REPLACEJUMPER WITHSMOKE/FIREDETECTOR

5

RD

O

T2

LPS

PLF 1

R

BK

2 STAGE COOLING

C

2

R-P

S1 S

N

HPS

BL

LINE VOLTAGE

1

2

C

YL

Y2

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM "3" AND "4" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED.3. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.4. USE COPPER CONDUCTORS ONLY

++ USE N.E.C. CLASS 2 WIRE5. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY.6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED.7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.

BL

/

O

PLF 2

YL/PK

COMP

3

C

NO ECONOMIZER

24V

SEENOTE 6

YL/PK

WH

C-RV

R

R

208-240/1/60 0140L02907-B

DC

OR

1

BK

RD

R-D

FT

BL

RD

BK

R

G

BK

Y2HVDR

W2

6

HVDRC

RD

CNT

STAT

OF OVER CURRENT PROTECTION

208-240V

208-240/1/60

PS2

PU

DF1

T

WIRE CODE

BL

DF2

SEE NOTE 4

BL/PKEM

1

4

C

SEE NOTE 3

PLF1

G

YL

2

G

BR

Y

BR

M

TB1

CHS

T2

R

C

OR

DFT

Y1

5

RVC

WH

DFTBK

RD

RD

PU

WH

W

NOTE 5

NOTE 6

9

78

RD

8 79

RO G CY1W1W2 Y2S2S1 RO G CY1W1

THERMOSTAT

W2S2S1

S2S1

RDRDBR

PK

Y2

Y2Y2

Y2

EQUIPMENT GROUND

FIELD GROUND

FIELD SPLICE

SWITCH (TEMP)

IGNITER

SWITCH (PRESS.)

OVERCURRENTPROT. DEVICE

JUNCTION

TERMINALINTERNAL TO

INTEGRATED CONTROL

PLUG CONNECTION

++

++

++

OPTIONALLOW VOLTAGE

SEE NOTE 2

Wiri

ng i

s su

bjec

t to

cha

nge.

Alw

ays

refe

r to

the

wiri

ng d

iagr

am o

n th

e un

it fo

r th

e m

ost

up-t

o-da

te w

iring

.⚠

War

ning

High

Vol

tage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Failu

re to

do

so m

ay c

ause

pro

pert

y da

mag

e, p

erso

nal i

njur

y, o

r de

ath.⚡

Page 31: DTH Commercial

SS-DTH3 www.daikinac.com 31

Wiring Diagram — 3 Through 5 Ton (230V, 3-Phase, Direct Drive)

BKBK

OR

BR

C3 BL1

24V

PK

TR208

BL

HPS

RD

RD

6

GND

/

RD

DFT

RD

208-240

L3

T2

T3

SEE UNIT RATING PLATE FOR TYPE AND SIZE

PU

PU

5

BK

BL

PLF 2

5

OF OVER CURRENT PROTECTION

4

CONTACTORCOMPRESSOR CONTACTOR RELAYCRANKCASE HEATERCRANKCASE HEATER SWITCHCONDENSER MOTORCOMPRESSORDEFROST CONTROLDEFROST THERMOSTATECONOMIZEREVAPORATOR MOTOREQUIPMENT GROUNDHIGH PRESSURE SWITCHHIGH VOLTAGE DEFROST RELAYLOW PRESSURE SWITCHLOW VOLTAGE DEFROST RELAYLOW VOLTAGE JUNCTION BOXFEMALE PLUG / CONNECTORREVERSING VALVE COILRUN CAPACITOR FORCONDENSER FANTERMINAL BLOCK (24V SIGNAL)TRANSFORMERREVERSING VALVE

RD

L3

T3

BK

2

C

C

WH

8

L2

PLF2

CM

BK

C

CCCRCHCHSCMCOMPDCDFTECONEMGNDHPSHVDRLPSLVDRLVJBPLFRVCRCCF

TB1TRRV

60

HVDR

RD

PU

6

T1

4

C

RVC

L1

/

BK

CM

PU

L1

COMPONENT LEGEND

PU

5

7

6

BL

3

BK

208-240/3/60 0140L02908-B

F

YL

PLF 1

DF2

PLF1

C 3

T2

RCCF

BR

COMP

9

DF1

T2

BK

T1

3

BL

BR

4

RD

1

SEENOTE 4

GR

T1

T3

L2

2

C

RD BR

RCCF

1

F

C

YL

ORBR

LVJB

RD

WH

PUGR

N

WH

BK

C

TB1

1 4 5

RD

2

YL

EMGL

3

GR

TB1

BL

2240

BK

RD

BL

H

T

O

R

W2T

Y1T

G

Y2

A

W1

E

M

SOC

R

BL

G

LN

SEE NOTE 2

EM

EM C2

45

3

1

HPS

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE

WHITE AND YELLOW LEADS FROM "3" AND "4" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE

HIGHER SPEED SETTING IS USED.3. FOR 208 VOLT TRANSFORMER OPERATION MOVE

BLACK WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.4. USE COPPER CONDUCTORS ONLY

++ USE N.E.C. CLASS 2 WIRE5. ECONOMIZER PLUG LOCATED IN THE RETURN AIR

COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY.6. CRANKCASE HEATER AND CRANKCASE HEATER

SWITCH FACTORY EQUIPPED WHEN REQUIRED.

WH

YL

WHWH

BL

BLBL

PU

GR

RD

4563 12

SEE NOTE 5

YLPU

BRWH

OR

1 5

OR

OR

LOW VOLTAGE

LINE VOLTAGE

FIELD WIRING

LOW VOLTAGE

FACTORY WIRING

HIGH VOLTAGE

BL

RD

OR

Y1

YL

W

BL

GR

OR

W

NO ECONOMIZER

G

OR

YL

RD

Y2

PK

WH

W

R RD

WHGR

C

O

RYL

O

GRGWH

WITH ECONOMIZER OPTION

C

GR

THERMOSTATFIELD WIRING

BL

C

O

2 STAGE COOLING

TB1

GR

W

Y

CO

TB1

TB1

Y

W

O

RG

C

W

Y2

GR

CO

Y1

STAT

STAT

STAT

BL/PK

RD

YL

T1

BK

T3 T2

YL

COMP

RD

GR GREEN

WIRE CODE

BL BLUE

PU PURPLEPK PINK

WH WHITE

BK BLACK

RD RED

BR BROWN

OR ORANGE

YL YELLOW

LPS

BL/PK

YL

BL

208-240/1/60SUPPLY VOLTAGE

Y1

Y1

RD

BK

2

TR

24V

3

SEE NOTE 3208-240V

RD

RD

CHS

CH

GR

SEE NOTE 6

BK

BK

BK

CHS

CH

SEE NOTE 6

SEE NOTE 6

YL/PKYL/PK

CONTROL BOXPU

DC

DFT

Y

CRRVC

CNTR-PS1 PS2

R

WO

DFT1 DFT2O-RV C-RV

YLYL

LPS

YL

1

PS2

CCR C

Y

Y

R-PS

1

R-DF

T

DFT

0

CNTCCR

HVDR

LVDR

W

C-RV

0-RV

0

DF2

DF1

R DC

OPTIONAL HIGHVOLTAGE

87

9

789

RO G CY1W1W2 Y2S2S1 RO G CY1W1

THERMOSTAT

W2S2S1

S2S1

BL

RDRDBR PK

Y2

Y2

EQUIPMENT GROUND

FIELD GROUND

FIELD SPLICESWITCH (TEMP)

IGNITER

SWITCH (PRESS.)

OVERCURRENTPROT. DEVICE

JUNCTION

TERMINALINTERNAL TO

INTEGRATED CONTROLPLUG CONNECTION

++

++

++

OPTIONAL LOWVOLTAGE

REPLACE JUMPER WITH SMOKE/FIRE DETECTOR

SEE NOTE 3

SEE NOTE 2

Wiri

ng i

s su

bjec

t to

cha

nge.

Alw

ays

refe

r to

the

wiri

ng d

iagr

am o

n th

e un

it fo

r th

e m

ost

up-t

o-da

te w

iring

.⚠

War

ning

High

Vol

tage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Failu

re to

do

so m

ay c

ause

pro

pert

y da

mag

e, p

erso

nal i

njur

y, o

r de

ath.⚡

Page 32: DTH Commercial

32 www.daikinac.com SS-DTH3

WIRING DIAGRAMS FOR MODELS WITH DDC CONTROLSFor complete information and installation instructions for models

with DDC controls, see manual DK-DDC-TGD-XXX

Page 33: DTH Commercial

SS-DTH3 www.daikinac.com 33

Wiring Diagram with DDC – DTH036/DTH048/DTH060*** (208-230V/1/60) D***

GN

D

LDS

GN

DG

ND

CO

M3-

8

RL8

AO

4

BI6

BI5

BI1

BI2

BI3

RS

S B

I4

BI8

CO

M2

24V

TR1

124

02

3C

208

24V

TR2

124

02

3C

208

T1T2

L1L2

CO

MP

CM

SM

K/E

MG

208-

240/

1/60

SEE

NO

TE 2

BI7

CFS

PK

WH

PK

RD

YL 14

HE

ATE

RP

LF

CL 2B

R BK

BK

DFT

RD

RD

BKBK

GR

PU

BK

BKRD

RD

RD

BK

BKC

FC

DA

T A

I1

GN

D

AG

ND

24V

AC

AI4

AI5

AI6

AI7

AI8

AI2

AI3

BK

BR

GR

CH

S

RV

C

BL

BL

RD

24V

RD

RD

BL

RD

SEE

NO

TE 4

YL

RD

PK

RD

YL

BK

RDRD

BK

RD

RD

BK

RD

WH

RD

BL

BL

BKYL BR

BR

WH OR

OR

BK RD

BK

BK

RD

23

56

78

9

T 2 T1L 1

BK

BK

RD

BL

AG

C

PU

T5T4

T3T2

T1

TB2

TB1

RD

SEE

NO

TE 5

CS

PSE

SXS

BKP

U

BL

OA

T+ - + -HG

RH

EXF

ALR

M

AG

ND

+ -

GR

AO

3

AO

2

AO

1

CO

M3-

8

RL7

RL6

RL5

RL4

RL3R

L2R

L1

CO

M1

BK

BL

BL

208-

240/

1/60

014

0L05

813-

A

GN

DV

OU

T D

C

OARH SPCRH

STP

TO

FFS

ET

GN

D

TEM

P

SPCTEMP VO

UT

DC

GN

D

CO2VO

UT

DC

GN

D

24V

AC

CO

M

BL

WH

WH

BK GR

BPS

WG

RB

K

YL/P

KB

L/PK

BL/ PK

HP

SLP

SYL

YL/

PK

YL

RD

BKR

D

BL

BL

DA

PU

PU

WH

GR

WH

412 5

3 6

EC

ON

BK

BR

WH

RD

RD

BK

BK

24 V

AC

FC

H

TB

YLR

D

RC

CF

PU

BR

GT4

EM

LT3T2

T1 CNT5

RD

RD

BK

BK

BL

BK

OR

WH

BR

PU

YL

OR

WH

BR

PU

YL

GR

WH

BR

BR

WH

WH

GR

POW

ER

SU

PPLY

SEE

NO

TE 7

CC

BL

BL

RD

Wiri

ng i

s su

bjec

t to

cha

nge.

Alw

ays

refe

r to

the

wiri

ng d

iagr

am o

n th

e un

it fo

r th

e m

ost

up-t

o-da

te w

iring

.⚠

War

ning

High

Vol

tage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Failu

re to

do

so m

ay c

ause

pro

pert

y da

mag

e, p

erso

nal i

njur

y, o

r de

ath.⚡

Page 34: DTH Commercial

34 www.daikinac.com SS-DTH3

Wiring Diagram with DDC – DTH036/DTH048/DTH060*** (208-230V/1/60) D***

BL/

PK

B

LUE

WIT

H P

INK

STR

IPE

PK

P

INK

YL/P

K

YELL

OW

WIT

H P

INK

STR

IPE

WIR

E C

OD

E

OF

OV

ER

CU

RR

EN

T P

RO

TEC

TIO

N

LIN

E V

OLT

AGE

OP

TIO

NA

L H

IGH

VO

LTA

GE

LOW

VO

LTA

GE

RD

R

EDFA

CTO

RY

WIR

ING

LOW

VO

LTA

GE

BL

BLU

EBK

B

LAC

K

NO

TES

:

1. R

EP

LAC

EM

EN

T W

IRE

MU

ST

BE

SA

ME

SIZ

E A

ND

T

YPE

INS

ULA

TIO

N A

S O

RIG

INA

L (A

T LE

AS

T 10

5°C

)

US

E C

OP

PE

R C

ON

DU

CTO

R O

NLY

.2.

US

E C

OP

PE

R C

ON

DU

CTO

RS

ON

LY

++

USE

N.E

.C. C

LAS

S 2

WIR

E3.

EC

ON

OM

IZE

R P

LUG

LO

CA

TED

IN T

HE

RE

TUR

N A

IR

CO

MP

AR

TME

NT.

RE

MO

VE

MA

LE P

LUG

AN

D A

TTA

CH

F

EM

ALE

PLU

G T

O T

HE

EC

ON

OM

IZE

R A

CC

ESS

OR

Y.4.

FO

R 2

08 V

OLT

TR

ANS

FOR

ME

R O

PER

ATI

ON

MO

VE

B

LAC

K W

IRE

FR

OM

TE

RM

INAL

3 T

O T

ER

MIN

AL

2

ON

T

RA

NSF

OR

ME

R.

5.R

EMO

VE

JU

MPE

R IF

SM

OKE

DE

TEC

TOR

OR

EM

ER

GE

NC

Y

SH

UTD

OW

N D

EV

ICE

IS IN

STA

LLE

D.

6. C

RA

NK

CA

SE

HE

ATE

R A

ND

CR

AN

KC

ASE

HE

ATE

R

SW

ITC

H F

AC

TOR

Y E

QU

IPP

ED

WH

EN

RE

QU

IRE

D.

7. F

OR

DIF

FER

EN

T TH

AN

FA

CTO

RY

SPE

ED

TA

P. C

HA

NG

EC

OO

LIN

G S

PE

ED

AT

MO

TOR

T4

AN

D T

5 TE

RM

INA

LS. C

HA

NG

EH

EATI

NG

SP

EE

D A

T M

OTO

R T

1, T

2 A

ND

T3.

SP

EED

TA

PTE

RM

INAT

ION

S S

HO

WN

ON

DIA

GR

AM

AR

E R

EP

RES

EN

TATI

VE

BU

T A

CTU

AL

FAC

TOR

Y S

ETT

ING

S M

AY

BE D

IFFE

RE

NT

BA

SE

DO

N T

HE

HE

ATI

NG

VA

LUE

OF

THE

UN

IT.

CO

OLI

NG

SP

EED

(GR

EE

N A

ND

BR

OW

N)

T3

- LO

W S

PEE

D

T

4 - H

IGH

SP

EED

HE

ATI

NG

SPE

ED

(WH

ITE

)

T

1 - L

OW

SPE

ED

T2

- ME

D S

PE

ED

T5

- HIG

H S

PEE

D

OR

O

RA

NG

E

SE

E U

NIT

RA

TIN

G P

LATE

FO

R T

YPE

AN

D S

IZE

YL

YELL

OW

GR

G

RE

EN

WH

W

HIT

E

208-

240/

1/60

BR

B

RO

WN

CO

MP

ON

EN

T LE

GE

ND

FIEL

D W

IRIN

GH

IGH

VO

LTA

GE

PU

P

UR

PLE

FIEL

D S

PLI

CE

SW

ITC

H (T

EM

P)

O

PTI

ON

AL

LOW

VO

LTA

GE

45

6 HEA

TER

PLF

CFS

LDS

RS

S

BP

SW

3

24V

TR

1

HP

S

3

24V

TR

1

LPS

BI1

BI2

BI3 BI5

BI6 BI7

BI8 AI1

AI2 AI4 AI5

AI6

AI7

AI8

AGN

D

OA

TD

AT

431 2

CO

M1

RL1 RL2

CO

M2

CO

M3-

8

AI3

RL3

RL4

RL5

CC

R1

RL6

RL7

RL8

24V

AC

GN

D

EC

ON

PLF

SMK

/EM

G

AO1

AO2

AO3

AO4

DD

C

L2

T1C

OM

P

T2

SUP

PLY

VO

LTA

GE

CM

L1

CC

208-

240/

1/60

CC

RC

CF

BI42

2

CH

SEE

NO

TE 6

208/

240/

1/60

208/

240/

1/60

CH

S

SW

ITC

H (P

RE

SS.)

OV

ER

CU

RR

EN

TP

RO

T. D

EVI

CE

TER

MIN

AL

PLU

G C

ON

NE

CTI

ON

FIE

LD G

RO

UN

D

IGN

ITE

R

JUN

CTI

ON

SC

HE

MAT

IC S

YMB

OL

SE

E N

OTE

5

+ - + -HG

RH

EXF

ALR

M+ -

014

0L05

853-

A

OA

RH

CO

2

SP

CTE

MP

CO

M

SE

NS

OR

OFF

SE

T

SP

CR

H

TB

AG

ND

AO

AI

ALR

MB

IB

LSB

PSW

CC

CC

RC

FC

F CC

FSC

HC

HS

CM

CO

MC

OM

PC

SD

FTE

CO

N

DC

GR

OU

ND

FO

R A

NA

LOG

SEN

SO

RS

("A

G" O

N T

B2)

4 A

NA

L OG

OU

TPU

T S8

AN

AL O

G IN

PU

TSA

LAR

M8

BIN

A RY

INP

UTS

BLO

WE

R L

OW

SP

EE

DB

LOW

ER

PR

OV

ING

SW

ITC

HC

OM

PRE

SS

OR

CO

NTA

CT O

RC

OM

PR

ES

SO

R C

ON

TAC

T OR

RE

LAY

CO

ND

ENS

OR

FA

NC

ON

DE N

SO

R F

AN

CO

NTA

CTO

RC

LOG

GED

FIL

TER

SW

ITC

HC

RA

NK

CA

SE H

EA

TER

CR

AN

KC

ASE

HE

ATE

R S

WIT

CH

CO

ND

ENS

ER

MO

TOR

CO

MM

ON

("C

" ON

TB2

)C

OM

PRE

SS

OR

CO

M1

AN

D S

MO

KE

DE

TEC

TOR

DE

FRO

ST

THE

RM

OS

TAT

EC

ON

OM

IZE R

EM ES

EXF

GN

DH

GR

HH

PS

LDS

LPS

OA

TO

AR

HP

LFP

SR

CC

FR

LR

SS

RV

CS

A T/D

AT

S MK

/EM

GS

PCTE

MP

SPC

RH

T1-T

5

TB1-

2TR

1-2

XS

EVA

PO

RA

TOR

MO

TOR

EC

ON

CO

M3-

8,B

I1 A

ND

SM

OK

E D

ET E

CTO

RE

XHA

US

T F A

NE

QU

IPM

EN

T G

RO

UN

DH

OT

GA

S R

EH

EAT

HIG

H P

RE

SSU

RE

SW

ITC

HLO

AD

SH

ED

DIN

GLO

W P

RES

SU

RE

SW

ITC

HO

UTD

OO

R A

IR T

EM

PER

ATU

RE

OU

TDO

OR

AIR

RE

LATI

VE H

UM

IDIT

YFE

MAL

E P

LUG

/ C

ON

NE

CTO

RH

PS

, LP

S &

SM

OKE

DE

TEC

TOR

RU

N C

A PAC

ITO

R F

OR

CO

ND

EN

SER

FA

NR

ELA

YR

EM

OTE

STA

RT

STO

PR

EV

E RS

ING

VAL

VE C

OIL

SU

PP

L Y /

DIS

CH

AR

GE

AIR

TE

MPE

RA

TUR

ES

MO

KE

OR

EM

ER

GE N

CY

SH

UTD

OW

NS

PAC

E TE

MPE

RA

TUR

ES

PAC

E R

ELA

TIV

E H

UM

IDIT

YM

OTO

R S

PEE

D T

APS

1-5

(DIR

EC

T D

RIV

EN

MO

TOR

ON

LY)

TER

MI N

AL

BL O

CK

(24V

SIG

NA

L)TR

AN

S FO

RM

E R24

VA

C T

RA

NS

FOR

ME

R &

SM

OK

ED

ETE

CTO

R

CO

MP

ON

EN

T LE

GE

ND

FH

C

DFT

RV

C

CFC

CM

RC

CF

FH

C

EMG T4

EM

L T3T2

T1CN T5

C

T2T1

T5

T3T4E

MC

T2T1

T5

T3T4E

M

TB1

TB1

CFC

T1

SEE

NO

TE 2

SEE

NO

TE 4

Wiri

ng i

s su

bjec

t to

cha

nge.

Alw

ays

refe

r to

the

wiri

ng d

iagr

am o

n th

e un

it fo

r th

e m

ost

up-t

o-da

te w

iring

.⚠

War

ning

High

Vol

tage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Failu

re to

do

so m

ay c

ause

pro

pert

y da

mag

e, p

erso

nal i

njur

y, o

r de

ath.⚡

Page 35: DTH Commercial

SS-DTH3 www.daikinac.com 35

Wiring Diagram with DDC – DTH036/DTH048/DTH060*** (208-230V/3/60) D***

GN

D

LDS

GN

DG

ND

CO

M3-

8

RL8

AO

4

BI6

BI5

BI1

BI2

BI3

RS

S B

I4

BI8

CO

M2

24V

TR1

124

02

3C

208

24V

TR2

124

02

3C

208

T3

L3

T1T2

L1L2

CO

MP C

M

SM

K/E

MG

PO

WE

R S

UPP

LY

208-

240/

3/60

SEE

NO

TE 2

BI7

CFS

PK

WH

PK

RD

YL

GR

14

HE

ATE

RP

LF

CL 2B

R BKB

K

DFT

RD

RD

BKBK

GR

FC

PU

PU

RD

BKRD

RD

BK

RD

BK

RC

CF

BKC

FC

CC

DA

T A

I1

GN

D

AG

ND

24VA

C

AI4

AI5

AI6

AI7

AI8

AI2

AI3

BKB

R

GR

CH

S

RV

C

BL

BL

RD

24V

RD

RD

BLB

L

RD

SE

E N

OTE

4

YL

RD

PK

RD YL BK

RDRD

BK

RD

RD

BK

RD

WH

RD

BL

BL

BKYL BR

WH

OR

OR

RD

BK

BK

RD

23

56

78

9

T 2 T 1L 1

BK

BKRD

BL

AG

C

PU

T5T4

T3T2

T1

TB2

TB1

RD

CS

PS

ES

XS

RD

BK

PU

BL

OA

T+ - + -HG

RH

EXF

ALR

M

AG

ND

+ -

GR

AO

3

AO

2

AO

1

CO

M3-

8

RL7

RL6

RL5

RL4

RL3R

L2R

L1

CO

M1

BK

BL

BL

208-

240/

3/60

014

0L05

812-

A

GN

DV

OU

T D

C

OARH SPCRH

STP

TO

FFS

ET

GN

D

TEM

P

SPCTEMP VO

UT

DC

GN

D

CO2VO

UT

DC

GN

D

24VA

C

CO

M

BL

WH

WH

BK

GR

BR

BPS

WG

RBK

YL/P

KB

L/P

KB

L/ PK

HP

SLP

SYL

YL/

PK

YL

RD

BK

RD BL

BL

DA

PU

PU

WH

GR

WH

412 5

3 6

EC

ON

BKB

RW

H

RD

RD

BK

BK

24 V

AC

RD BK

BL

BL

RD

BL

BL

WH

YL

WH

BR

ORW

HB

RP

UY

L

GR

BR

OR

WH

BR

PU

YL

RD

TB

BK

EM GT4

LT3T2

T1 CNT5

SEE

NO

TE 7

SEE

NO

TE 5

WH

BR

Wiri

ng i

s su

bjec

t to

cha

nge.

Alw

ays

refe

r to

the

wiri

ng d

iagr

am o

n th

e un

it fo

r th

e m

ost

up-t

o-da

te w

iring

.⚠

War

ning

High

Vol

tage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Failu

re to

do

so m

ay c

ause

pro

pert

y da

mag

e, p

erso

nal i

njur

y, o

r de

ath.⚡

Page 36: DTH Commercial

36 www.daikinac.com SS-DTH3

Wiring Diagram with DDC – DTH036/DTH048/DTH060*** (208-230V/3/60) D***

BL/

PK

BL

UE

WIT

H P

INK

STR

IPE

PK

P

INK

YL/

PK

YE

LLO

W W

ITH

PIN

K S

TRIP

E

WIR

E C

OD

E

OF

OV

ER

CU

RR

EN

T P

RO

TEC

TIO

N

LIN

E V

OLT

AG

E

OPT

ION

AL H

IGH

VO

LTA

GE

LOW

VO

LTA

GE

RD

R

EDFA

CTO

RY

WIR

ING

LOW

VO

LTA

GE

BL

BLU

EB

K

BLA

CK

NO

TES

:

1. R

EPL

AC

EM

EN

T W

IRE

MU

ST

BE

SA

ME

SIZ

E A

ND

T

YPE

INS

ULA

TIO

N A

S O

RIG

INAL

(AT

LEA

ST

105°

C)

U

SE

CO

PP

ER

CO

ND

UC

TOR

ON

LY.

2. U

SE

CO

PPE

R C

ON

DU

CTO

RS

ON

LY

++

US

E N

.E.C

. CLA

SS

2 W

IRE

3. E

CO

NO

MIZ

ER

PLU

G L

OC

ATE

D IN

TH

E R

ETU

RN

AIR

C

OM

PA

RTM

EN

T. R

EM

OV

E M

ALE

PLU

G A

ND

ATT

AC

H

FE

MA

LE P

LUG

TO

TH

E E

CO

NO

MIZ

ER

AC

CES

SO

RY

.4.

FO

R 2

08 V

OLT

TR

AN

SFO

RM

ER

OP

ERAT

ION

MO

VE

B

LAC

K W

IRE

FR

OM

TE

RM

INAL

3 T

O T

ER

MIN

AL 2

O

N

TR

AN

SFO

RM

ER

.5.

RE

MO

VE

JU

MP

ER

IF S

MO

KE

DET

EC

TOR

OR

EM

ER

GE

NC

Y

SH

UTD

OW

N D

EV

ICE

IS IN

STAL

LED

.6.

CR

AN

KC

AS

E H

EATE

R A

ND

CR

AN

KCA

SE

HE

ATE

R

SW

ITC

H F

AC

TOR

Y E

QU

IPP

ED

WH

EN

REQ

UIR

ED

.7.

FO

R D

IFFE

REN

T TH

AN

FA

CTO

RY

SPE

ED

TA

P. C

HAN

GE

CO

OLI

NG

SP

EE

D A

T M

OTO

R T

4 A

ND

T5

TER

MIN

ALS

. CH

AN

GE

HE

ATIN

G S

PEE

D A

T M

OTO

R T

1, T

2 A

ND

T3.

SP

EE

D T

AP

TER

MIN

ATIO

NS

SH

OW

N O

N D

IAG

RA

M A

RE

RE

PR

ES

EN

TATI

VE

BU

T A

CTU

AL F

ACTO

RY

SET

TIN

GS

MA

Y B

E D

IFFE

REN

T B

AS

ED

ON

TH

E H

EAT

ING

VAL

UE

OF

THE

UN

IT.

CO

OLI

NG

SP

EE

D (G

REE

N A

ND

BR

OW

N)

T3

- LO

W S

PE

ED

T4

- HIG

H S

PE

ED

HE

A TIN

G S

PEE

D (W

HIT

E)

T1

- LO

W S

PE

ED

T2

- ME

D S

PEE

D

T

5 - H

IGH

SP

EE

D

OR

O

RAN

GE

SE

E U

NIT

RAT

ING

PLA

TE F

OR

TY

PE

AN

D S

IZE

YL

YEL

LOW

GR

G

REE

N

WH

W

HIT

E

208-

240/

3/60

BR

B

RO

WN

CO

MP

ON

EN

T LE

GEN

D

FIE

LD W

IRIN

GH

IGH

VO

LTA

GE

PU

P

UR

PLE

FIE

LD S

PLIC

E

SW

ITC

H (T

EM

P)

O

PTIO

NAL

LO

W V

OLT

AG

E

45

6 HE

ATE

RPL

F

CFS

LDS

RS

S

BP

SW

3

24V

TR

1

HP

S

3

24V

TR

1

LPS

BI1

BI2

BI3 BI5

BI6 BI7

BI8 AI1

AI2 AI4 AI5

AI6

AI7

AI8

AG

ND

OAT

DAT

431 2

CO

M1

RL1 RL2

CO

M2

CO

M3-

8

AI3

RL3

RL4

RL5

CC

R1

RL6

RL7

RL8

24V

AC

GN

D

EC

ON

PLF

SM

K/E

MG

AO

1

AO

2

AO

3

AO

4

DD

C

L2

T1C

OM

P

T2

SU

PPL

Y V

OLT

AG

E

CM

L1

CC

208-

240/

3/60

CC

RC

CF

BI42

2

CH

SE

E N

OTE

6

208/

240/

3/60

208/

240/

3/60

CH

S

SW

ITC

H (P

RES

S.)

OV

ERC

UR

RE

NT

PR

OT.

DE

VIC

E

TER

MIN

AL

PLU

G C

ON

NE

CTI

ON

FIE

LD G

RO

UN

D

IGN

ITE

R

JUN

CTI

ON

SC

HE

MAT

IC S

YM

BO

L

SE

E N

OTE

5

+ - + -HG

RH

EXF

ALR

M+ -

014

0L05

852-

A

OA

RH

CO

2

SP

CTE

MP

CO

M

SEN

SO

R

OFF

SET

SP

CR

H

TB

AGN

D

AO AI ALR

MBI BL

SBP

SWC

CC

CR

CF

CFS

CH

CH

SC

MC

OM

CO

MP

CS

DFT

ECO

N

DC

GR

OU

ND

FO

R A

NAL

OG

SEN

SOR

S ("

AG" O

N T

B2)

4 AN

ALO

G O

UTP

UT S

8 AN

ALO

G IN

PUTS

ALAR

M8

BIN

A RY

INP U

TSBL

OW

ER L

OW

SP

EED

BLO

WER

PR

OVI

NG

SW

ITC

HC

OM

PRES

SOR

CO

NTA

CTO

RC

OM

PRES

S OR

CO

NTA

CTO

R R

ELA Y

CO

ND

ENSO

R F

A NC

LOG

GED

FIL

TER

SW

ITC

HC

RAN

KCA S

E H

EATE

RC

RAN

KCA S

E H

EATE

R S

WIT

CH

CO

ND

ENSE

R M

OTO

RC

OM

MO

N ("

C" O

N T

B 2)

CO

MPR

ESSO

RC

OM

1 AN

D S

MO

KE D

ETEC

TOR

DE F

RO

ST T

HE R

MO

STA T

ECO

NO

MIZ

ER

EM

ES EXF

GN

DH

GR

HH

P SLD

SLP

SO

ATO

A RH

PLF

PS RC

CF

RL

RS S

RVC

SAT/

DA T

SMK/

EMG

SPC

TEM

PSP

CR

HT1

-T5

TB1-

2TR

1-2

XS

EVAP

OR

ATO

R M

OTO

REC

ON

CO

M3 -

8,BI

1 A N

D S

MO

KE D

ETE

CT O

REX

HA U

ST F

AN

EQU

IPM

ENT

GR

OU

ND

HO

T G

AS R

EHEA

TH

IGH

PR

E SSU

RE

SW

ITC

HLO

A D S

HED

DIN

GLO

W P

RES

SUR

E SW

ITC

HO

UTD

OO

R A

IR T

E MPE

RAT

UR

EO

UTD

OO

R A

IR R

ELAT

IVE

HU

MID

ITY

FEM

ALE

PL U

G /

CO

NN

EC

TOR

HPS

, LPS

& S

MO

KE D

ETEC

T OR

RU

N C

A PA

CIT

OR

FO

R C

ON

DEN

SER

FA N

REL

AYR

E MO

TE S

TAR

T S

TOP

RE V

ER

SIN

G V

ALVE

CO

ILSU

PPL Y

/ D

ISC

HAR

GE

AIR

TE

MPE

RAT

UR

ES

MO

KE O

R E

MER

GEN

CY

SHU

TDO

WN

SPAC

E TE

MPE

RAT

UR

ESP

A CE

REL

ATIV

E H

UM

IDIT

YM

OT O

R S

PEE D

TA

PS 1

-5(D

IREC

T D

RIV

EN

MO

TOR

ON

LY)

TER

MIN

AL B

LOC

K ( 2

4V S

IGN

AL)

TRA N

SFO

RM

ER24

VAC

TR

ANS F

OR

MER

& S

MO

KED

ETE C

TOR

CO

MP

ON

EN

T LE

GEN

D

FH

C

CM

RC

CF

FH

C

EMG T4

EM

L T3T2

T1CN T5

C

T2T1

T5

T3T4EM

C

T2T1

T5

T3T4EM

TB1

TB1

L3

CC

T3

RV

C

CFC

DFT

TB

EMG T4

EM

L T3T2

T1CN T5

SE

E N

OTE

2

SE

E N

OTE

4

CFC

T1

Wiri

ng i

s su

bjec

t to

cha

nge.

Alw

ays

refe

r to

the

wiri

ng d

iagr

am o

n th

e un

it fo

r th

e m

ost

up-t

o-da

te w

iring

.⚠

War

ning

High

Vol

tage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Failu

re to

do

so m

ay c

ause

pro

pert

y da

mag

e, p

erso

nal i

njur

y, o

r de

ath.⚡

Page 37: DTH Commercial

SS-DTH3 www.daikinac.com 37

Accessories

Daikin Master Item # Description Fits

Model SizesField-

InstalledFactory- Installed

Operating Weight (lbs)

Curb14CURB3672 14” Roof Curb 3-5 tons √ 86

18CURB3672B 18” Roof Curb 3-5 tons √ 100

24CURB3672B 24” Roof Curb 3-5 tons √ 128

GHRC-3672 Hurricane Restraint Clips 3-5 tons √ 2

Ultra Low-Leak Economizer & Power Exhaust1

1036609C Ultra Low-Leak Downflow Economizer w/ Enthalpy 3-5 Tons √ √ 71

1039609 Ultra Low-Leak Horizontal Economizer w/ Enthalpy 3-5 Tons √ 71

104650921 Prop Power Exhaust 230v 3-5 Tons √ 55

Low-Leak Economizer & Power Exhaust2

DDNECNJ3672C Low-Leak Downflow Economizer 3-5 tons √ √ 82

DPE36722 Downflow Power Exhaust (208/230 Volt) 3-5 tons √ 55

DINHZ3672B Horizontal Economizer, Internally Mounted 3-5 tons √ 90

DHZECNJ3672 Horizontal Economizer 3-5 tons √ 70

DHPE36722 Horizontal Power Exhaust (208/230 Volt) 3-5 tons √ 55

Downflow AccessoriesD25FD3672 25% Manual Fresh Air Damper 3-5 tons √ 12

D25MFD3672 25% Motorized Fresh Air Damper 3-5 tons √ 16

DDNBBS3672 Burglar Bar Sleeves with Supply & Return 3-5 tons √ 30

DDNECNJ3672NR Downflow Economizer2 w/o Barometric Relief 3-5 tons √ 77

DDNSQRD3616 Downflow Square-to-Round Adapter (16” Round) 3 tons √ 45

DDNSQRD487218 Downflow Square-to-Round Adapter (18” Round) 4-5 tons √ 35

Horizontal AccessoriesDBRD3672 Horizontal Barometric Relief Damper 3-5 tons √ 15

ConcentricsCDK36 Concentric Duct Kit 3 tons √ 27

CDK4872 Concentric Duct Kit 4-5 tons √ 27

1 phase 208-230V Electric Heat KitsSPKT01 Single Point Wiring Kit 1phase Heat Kits 3-5 tons √ √

EHK1-10 10kw 208-230 1ph Electric Heat Kit 3-5 tons √ √ 21

EHK1-15 15kw 208-230 1ph Electric Heat Kit 3-5 tons √ √ 21

EHK1-18 18kw 208-230 1ph Electric Heat Kit 4 tons √ √ 21

EHK1-20 20kw 208-230 1ph Electric Heat Kit 5 tons √ √ 21

3 phase 208-230V Electric Heat KitsSPKT02 Single Point Wiring Kit 3phase Heat Kits 3-5 tons √ √

EHK3-10 10kw 208-230 3ph Electric Heat Kit 3-5 tons √ √ 21

EHK3-15 15kw 208-230 3ph Electric Heat Kit 3-5 tons √ √ 21

EHK3-18 18kw 208-230 3ph Electric Heat Kit 4 tons √ √ 21

Page 38: DTH Commercial

38 www.daikinac.com SS-DTH3

Accessories

Daikin Master Item # Description Fits

Model SizesField-

InstalledFactory- Installed

Operating Weight (lbs)

EHK3-20 20kw 208-230 3ph Electric Heat Kit 5 tons √ √ 21

DDC Accessories3

DDC communicating controller (built-in BACnet® MS/TP) includes Standard Room Sensor to be installed in field

3-5 tons √ 2

10366D09C DDC Ultra Low-Leak Downflow Economizer 3-5 tons √ √ 71

10396D09 DDC Ultra Low-Leak Horizontal Economizer 3-5 tons √ 71

10465DDCPower Exhaust kit used with DDC Ultra Low-Leak Economizer

3-5 tons √ 1

DLAKT01 Low-Ambient 3-5 tons √ √ 2

LONKT01 LonWorks® card 3-5 tons √ 1

3PMK01 Phase Monitor (3-Phase Only) 3-5 tons √ √ 2

DFSKT01 Dirty Filter Switch 3-5 tons √ 1

Crankcase Heater Kits0163R00002S 40W 230V 3 tons √ 1

0130L00017S 70W 230V 4 - 5 tons √ 1

High Efficiency Filters

0160L00203High Efficiency MERV 13 Air Filter Nom. Size: 24x24x2; (Order Qty 1)

3 tons √ 2

0160L00204High Efficiency MERV 13 Air Filter Nom. Size: 14x20x2; (Order Qty 4)

4 tons √ 4

0160L00205High Efficiency MERV 13 Air Filter Nom. Size: 16x20x2; (Order Qty 4)

5 tons √ 4

Misc AccessoriesHAILGD03D Condenser Coil Hail Guard 3-5 tons √ 19

HAILGD04D Condenser Coil Hail Guard 5 tons √ 22

Convenience Outlet: Non Powered 3-5 tons √ 2

Convenience Outlet: Powered 3-5 tons √ 42

LAKT11 Low Ambient Kit, 208-230V - non-DDC 3-4 tons √ √ 14

LAKT12 Low Ambient Kit, 208-230V - non-DDC 5 tons √ √ 14

3PMNDK01 Phase Monitor (3-Phase Only) - Non DDC 3-5 tons √ √ 2

Smoke Detector (supply and/or return air) 3-5 tons √ 11

Hinged Panels 3-5 tons √ 101 Use Economizer & Power Exhaust listed within Ultra Low-Leak section 2 Use Economizer & Power Exhaust listed within Low-Leak section 3 For a full list of DDC accessories, please refer to DDC Controller Technical Guide manual (DK-DDC-TGD-01B)Note: Where multiple variations are available, the heaviest combination is listed.

Page 39: DTH Commercial

SS-DTH3 www.daikinac.com 39

Notes

Page 40: DTH Commercial

40 www.daikinac.com SS-DTH3

Our continuing commitment to quality products may mean a change in specifications without notice. © 2018 • Houston, Texas • Printed in the USA.

Notes