Pressure Area Care

STATICIntroduction Air-Layer AdvanceGel-KoolGel-Kool+Memaflex AdvancePermaflex Plus AdvancePermaflex Non-Turn AdvancePermaflex AdvanceCommunity Advance Crib-Flex 7®Tri-flex MattressDuraflex A&E Trolley MattressMattress for Domestic, Care Home & Nursing Home UseStatic Cushions

DYNAMICIntroductionPhase IIIAmbience EliteSimple AirDelta PlusEclipse IIDouble PlusGenesisEclipse CushionPrelude Cushion

HYBRIDtIn roduction

Hybrid-PowerHybrid-Turn

05 - 2305

06 - 070809

10 - 1112 - 13

14 1516 171819

20 - 2122 - 23

25 - 4325

26 - 2728 - 2930 - 31

32 - 3334 -3536 - 3738 - 3940 -41

4243

45 - 4945

46 - 4748 - 49

4 5

Static Mattresses

A high specification foam mattress support surface is developed to

redistribute pressure - decreasing peak interface pressure.

6 7

Air-Layer

“The unique air layer surface helps to improve the micro-climate between the patient and the support surface”

VERY HIGH RISK

The Air-Layer combines the traditional benefits of a visco-elastic mattress with the latest air layer technology, to deliver optimum pressure reduction and exceptional patient comfort. The unique air layer surface helps to improve the micro-climate between the patient and the support surface, by reducing heat and vapour transfer rates by up to 25%.

Benefits for Healthcare Professionals » Suitable for use in Acute and

Community environments » Mattress best practice guidelines

clearly printed on the cover » Mattress does not require turning » Cover and foam can be

replaced individually

Infection Prevention » Ideal for users with hemiplegia,

paraplegia, tetraplegia and others who need extra forearm support » Lipped edging helps to keep

users arm in position » Angle adjustable for added

flexibility and support

Strikethrough Protective ShieldCleaning protocols can differ between individual organisations. To assist with these protocols the Air-Layer mattress surface incorporates a SodiumHypochlorite resistant cover, that will withstand a higher concentration of cleaning substances.

Proven Patient OutcomesImproved micro-climate Unique surface air layer reduces heat and vapour transfer rates between the patient and the support surface.

Minimised peak pressures Visco-elastic foam conforms to the body, helping to reduce pressure around the most vulnerable bony prominences.

Optimum pressure reductionHigh specification support surface contributes to an effective pressure ulcer prevention plan.

Reduced shear and friction forcesSmooth multi-stretch cover allows the patient to glide over the surface of the mattress.

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY

2001010001 39 stones / 247.7 kgs Very High Risk* 5 years cover, 5 years foam 198 x 88 x 16cm (Multiple sizes available) Complies to BS7177; Crib 5

Unique top surface Air-Layer with visco-elastic foam

8 9

Gel-Kool Gel-Kool +

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FATIGUE CLASS FIRE RETARDANCY

2001240001 39 stones / 247.7 kgs High Risk 5 years cover, 5 years foam 198 x 88 x 16 cm Severe Complies to BS7177; Crib 5

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FATIGUE CLASS FIRE RETARDANCY

2001250001 39 stones / 247.7 kgs High Risk 5 years cover, 5 years foam 198 x 88 x 16 cm Severe Complies to BS7177; Crib 5

» High Risk Mattress » Mattress does not require turning » High frequency welded

seams with concealed zip » Cover and foam can be

replaced individually

» High Risk Mattress » ‘U’ shaped foam base » High frequency welded

seams with concealed zip » Cover and foam can be

replaced individually

The Gel-Kool mattress features a castellated support surface and is designed to balance body heat by incorporating innovative gel technology. The castellated support surface sits on top of a single foam base to provide optimum patient support.

The Gel-Kool + mattress features a castellated support surface and is designed to balance body heat by incorporating innovative gel technology. Having a ‘U’ shaped foam base provides maximum support during patient transfers.

HIGH RISK HIGH RISK

Strikethrough Protective Shield Cleaning protocols can differ between individual organisations. To assist with these protocols the Gel-kool mattress surface incorporates a Sodium Hypochlorite resistant cover, that will withstand a higher concentration of cleaning substances. Innovative Gel Technology The Gel-Kool System introduces innovative technology to enhance patient outcomes. Gel infused visco-elastic foam creates a microclimate between the patient andthe support surface, balancing body heat and delivering a more comfortable sleeping experience. Regulating the skin’s temperature helps prevent skinbreakdown, reducing the risk of PUs. Sodium Hypochlorite Resistant Cover Cleaning protocols can differ between individual organisations. To assist with these protocols the Gel-Kool surface incorporates a Sodium Hypochlorite resistant cover, that will withstand ahigher concentration of cleaning substances. The Gel-Kool cover offers greater resistance to abrasionwithout compromising the protective properties of the cover.

Strikethrough Protective Shield Cleaning protocols can differ between individual organisations. To assist with these protocols the Gel-kool+ mattress surface incorporates a Sodium Hypochlorite resistant cover, that will withstand a higher concentration of cleaning substances. Innovative Gel Technology The Gel-Kool+ System introduces innovative technology to enhance patient outcomes. Gel infused visco-elastic foam creates a microclimate between the patient and the support surface, balancing body heat and delivering a more comfortable sleeping experience. Regulating the skin’s temperature helps prevent skinbreakdown, reducing the risk of PUs. Sodium Hypochlorite Resistant Cover Cleaning protocols can differ between individual organisations. To assist with these protocols the Gel-Kool+ surface incorporates a Sodium Hypochlorite resistant cover, that will withstand ahigher concentration of cleaning substances. The Gel-Kool+ cover offers greater resistance to abrasionwithout compromising the protective properties of the cover.

Castellated Foam Surface ‘U’ shaped base Castellations

1011

Memaflex

“High density visco-elastic foam surface ideal for delivering exceptional patient comfort”

HIGH RISK

Benefits for Healthcare Professionals » Suitable for use in Acute and

Community environments » Mattress best practice guidelines

clearly printed on the cover » Mattress does not require turning » Cover and foam can be

replaced individually » Also available in a bariatric, paediatric

and double size mattress

Infection Prevention » Waterproof, vapour permeable

cover can be easily wiped clean » High frequency welded seams

reduce the risk of fluid ingress » Zip is protected by a covered,

single sided, full length welded flap » Cover can be removed and

laundered at 80ºC

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY

2001020001 39 stones / 247.7 kgs High Risk* 5 years cover, 5 years foam 198 x 88 x 16cm (Multiple sizes available) Complies to BS7177; Crib 5

The Memaflex mattress features a high density visco-elastic foam surface, ideal for delivering exceptional patient comfort and a high degree of pressure reduction. The temperature sensitive foam conforms to the shape of the body, creating a greater contact area and providing effective pressure redistribution.

Strikethrough Protective Shield Cleaning protocols can differ between individual organisations. To assist with these protocols the Memaflex mattress surface incorporates a Sodium Hypochlorite resistant cover that will withstand a higher concentration of cleaning substances.

Proven Patient OutcomesMinimised peak pressures Visco-elastic foam conforms to the body, helping to reduce pressure around the most vulnerable bony prominences.

Optimum pressure reduction High specification support surface contributes to an effective pressure ulcer prevention plan.

Encouraged skin integrityInternal air channels in the foam’s surface help to reduce the build-up of heat and moisture on the skin.

Reduced shear and friction forcesSmooth multi-stretch cover allows the patient to glide over the surface of the mattress.

Enhanced patient positioningIndividual castellations conform independently, allowing the mattress to profile effectively.

Internal air channels in the foam’s surface

Also available in a mattress overlay

1213

Permaflex Plus Advance

“Castellated support surface within a ‘U’ shaped foam base”

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY

2001030003 39 stones / 247.7 kgs High Risk* 5 years cover, 8 years foam 198 x 88 x 16cm Complies to BS7177; Crib 5

HIGH RISK

Benefits for Healthcare Professionals » Suitable for use in Acute and

Community environments » Mattress best practice guidelines

clearly printed on the cover » Mattress does not require turning » Cover and foam (including u-shaped

base) can be replaced individually

Infection Prevention » Waterproof, vapour permeable

cover can be easily wiped clean » High frequency welded seams

reduce the risk of fluid ingress » Zip is protected by a double

sided, full length welded flap » Cover can be removed and

laundered at 80ºC

The Permaflex Plus Advance mattress is fully encased in an advanced outer cover material, constructed of a dense interlock knit polyurethane fabric and high frequency welded seams. These features combine to provide improved durability and an effective barrier to fluid ingress.

Advance Cover Technology The Permaflex Plus Advance mattress is fully encased in an advanced outer covermaterial, constructed of a dense interlock knit polyurethane fabric with high frequency welded seams. These features combine to provide improved durabilityand an effective barrier to fluid ingress.

Proven Patient OutcomesOptimum pressure reduction High specification support surface contributes to an effective pressure ulcer prevention plan.

Encouraged skin integrity Internal air channels in the foam’s surface help to reduce the build-up of heat and moisture on the skin.

Reduced shear and friction forcesSmooth multi-stretch cover allows the patient to glide over the surface of the mattress.

Enhanced patient positioningIndividual castellations conform independently, allowing the mattress to profile effectively.

‘U’ shaped foam base with castellated foam

‘U’ shaped base Castellations

1415

“Non-Turn mattress with castellated support surface”

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY

2001040001 39 stones / 247.7 kgs High Risk* 5 years cover, 5 years foam 198 x 88 x 16cm (Multiple sizes available) Complies to BS7177; Crib 5

HIGH RISK

Benefits for Healthcare Professionals » Suitable for use in Acute and

Community environments » Mattress best practice guidelines

clearly printed on the cover » Mattress does not require turning » Cover and foam can be

replaced individually

Infection Prevention » Waterproof, vapour permeable

cover can be easily wiped clean » High frequency welded seams

reduce the risk of fluid ingress » Zip is protected by a covered,

single sided, full length welded flap » Cover can be removed and

laundered at 80ºC

The Permaflex Non-Turn Advance mattress features a castellated support surface on top of a single piece foam base, designed to deliver excellent pressure reduction and provide optimum patient support.

Advance Cover Technology The Permaflex Non-Turn Advance mattress is fully encased in an advanced outer cover material, constructed of a dense interlock knit polyurethane fabric and high frequency welded seams. These features combine to provide improved durability and an effective barrier to fluid ingress.

Proven Patient OutcomesOptimum pressure reduction High specification support surface contributes to an effective pressure ulcer prevention plan.

Encouraged skin integrity Internal air channels in the foam’s surface help to reduce the build-up of heat and moisture on the skin.

Reduced shear and friction forcesSmooth multi-stretch cover allows the patient to glide over the surface of the mattress.

Enhanced patient positioningIndividual castellations conform independently, allowing the mattress to profile effectively.

Permaflex Non-Turn Advance Permaflex Advance

MEDIUM RISK

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY

2001050001 30 stones / 190.5 kgs Medium Risk* 5 years cover, 5 years foam 198 x 88 x 16cm (Multiple sizes available) Complies to BS7177; Crib 5

“Cost effective solution for pressure care management”

Benefits for Healthcare Professionals » Ideal for use in Community and

Nursing Home environments » Mattress best practice guidelines

clearly printed on the cover » Cover and foam can be

replaced individually » Also available in a bariatric,

paediatric and double size mattress

Infection Prevention » Waterproof, vapour permeable

cover can be easily wiped clean » Concealed zip helps to reduce

the risk of fluid ingress » Cover can be removed and

laundered at 80ºC

The Permaflex Advance mattress provides a cost effective solution to pressure ulcer management, whilst delivering the same excellent performance and reliability of the Permaflex range.

Advance Cover Technology The Permaflex Advance mattress is fully encased in an advanced outer covermaterial, constructed of a dense interlock knit polyurethane fabric, designed toprovide improved durability and an effective barrier to fluid ingress.

Proven Patient OutcomesOptimum pressure reduction High specification support surface contributes to an effective pressure ulcer prevention plan.

Encouraged skin integrity Internal air channels in the foam’s surface help to reduce the build-up of heat and moisture on the skin.

Reduced shear and friction forcesSmooth multi-stretch cover allows the patient to glide over the surface of the mattress.

Enhanced patient positioningIndividual castellations conform independently, allowing the mattress to profile effectively.

Four way turn castellated support surface Castellated foam surface

1617

Community Advance

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY

2001090001 26 stones / 165 kgs Medium Risk* 1 years cover, 1 years foam 198 x 88 x 12.5cm (Multiple sizes available) Complies to BS7177; Crib 5

Castellated foam base MEDIUM RISK

Benefits for Healthcare Professionals » Ideal for use in Community and

Nursing Home environments » Mattress best practice guidelines

clearly printed on the cover » Cover and foam can be

replaced individually » Also available in a double

size mattress

Infection Prevention » Waterproof, vapour permeable

cover can be easily wiped clean » Concealed zip helps to reduce

the risk of fluid ingress » Cover can be removed and

laundered at 80ºC

The Community Advance is an ideal entry level mattress, for patients at risk of developing pressure ulcers and requiring a high level of comfort.

Crib-flex 7® Mattress

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY

2001970001 40 stone / 254 kg Low Risk* 4 years cover, 1 years foam 198 x 88 x 16cm Source 0, 1 & Crib 7

LOW RISK

Benefits for Healthcare Professionals » Ideal for hazardous environments

such as prisons and mental health units, where there is a higher risk of the mattress being compromised

Infection Prevention » Waterproof, vapour permeable

cover can be easily wiped clean

The Crib-Flex 7 mattress is a durable Crib 7 surface with a non-removable cover. This mattress is designed to withstand damage to the mattress, as well as adhering to the highest standard of fire resistance.

1819

TRI-FLEX Mattress

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY

TRI/PBE 42 stones / 266.7 kgs Low to Medium Risk* 4 years cover, 4 years foam 193 x 91 x 15cm (Multiple sizes available) Complies to BS7177; Crib 5

Benefits for Healthcare Professionals » Ideal for use in community and

Nursing Home environments » Mattress best practice guidelines

clearly printed on the cover » Cover and foam can be replaced

individually also available in a double size mattress

The Tri-Flex mattress is a versatile mattress ideal for palliative care and nursing homes. Its unique design allows for complete freedom in positioning.

LOW/MEDIUM RISK

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY

2001070004 25 stones / 160 kgs Medium to High Risk* 1 years cover, 1 years foam 191 x 68 x 11.5cm Complies to BS7177; Crib 5

Duraflex A&E Trolley Mattress

The Duraflex A&E Trolley Mattress is designed to deliver a comfortable, pressure reducing support surface for patients awaiting treatment in A&E.

Benefits for Healthcare Professionals » Suitable for use in x-ray theatres » Compatible with a range of trolleys » Non-slip base

Infection Prevention » Waterproof, vapour permeable

cover can be easily wiped clean » High frequency welded seams

to reduce risk of infection » Zip protected by a full

length welded flap

MEDIUM/HIGH RISK

2021

Mattresses For Domestic, Care Home & Nursing Home Use

CODE MAT 10BE

MAXIMUM WEIGHT LIMIT 29 stones / 187.2 kgs

RISK FACTOR Medium Risk*

WARRANTY 1 years cover, 1 years foam

MATTRESS DIMENSIONS 198 x 90 x 12.7cm

FIRE RETARDANCY Complies to BS7177; 2008 medium hazard

CODE MAT 20BE

MAXIMUM WEIGHT LIMIT 31 stones / 200.6 kgs

RISK FACTOR High Risk*

WARRANTY 1 years cover, 1 years foam

MATTRESS DIMENSIONS 198 x 61 x 15.2cm

FIRE RETARDANCY Complies to BS7177; 2008 medium hazard

CODE MAT 30BE

MAXIMUM WEIGHT LIMIT 39 stones / 251.8 kgs

RISK FACTOR High to Very High Risk*

WARRANTY 1 years cover, 1 years foam

MATTRESS DIMENSIONS 198 x 61 x 7.5cm

FIRE RETARDANCY Complies to BS7177; 2008 medium hazard

MAT 10BE MAT 20BE MAT 30BE Specifications

Benefits for Healthcare Professionals » Single grade foam, profiled for

improved pressure care » Waterproof PU cover

Infection Prevention » Waterproof, vapour permeable

cover can be easily wiped clean » Sewn seam with zip closure » Cover can be removed

and laundered

Benefits for Healthcare Professionals » Single grade foam, profiled for

improved pressure care » Waterproof PU cover

Infection Prevention » Waterproof, vapour permeable

cover can be easily wiped clean » Sewn seam with zip closure » Cover can be removed

and laundered

Benefits for Healthcare Professionals » Single grade foam, profiled for

improved pressure care » Waterproof PU cover

Infection Prevention » Waterproof, vapour permeable

cover can be easily wiped clean » Sewn seam with zip closure » Cover can be removed

and laundered

MEDIUM RISK HIGH RISK HIGH RISK

This mattress is a general purpose replacement mattress with the benefits of a removable and washable PU cover.

This mattress is an ideal aid when used as part of a pressure ulcer prevention programme. It is general purpose replacement mattress proven in countless care institutions across the UK.

This mattress is an ideal replacement for existing high risk mattresses. The Geltex layer combines breathability, pressure distribution and body support in a way you don’t get with other materials due to its unique gel properties.

2223

Static Cushions

Permaflex Air-LayerGel-Kool Memaflex

MEDIUM RISK MEDIUM/HIGH RISK HIGH RISKHIGH RISK

The Permaflex pressure reducing cushion provides a contoured support surface with individually cut castellations on either side, providing optimum pressure reduction through effective weight re-distribution.

The Air-Layer pressure reducing cushion combines the traditional benefits of a visco-elastic cushion with the latest air layer technology, to improve comfort and pressure reduction.

The Gel-Kool cushion offers a solution to 24 hour pressure care and balanced body heat, through the innovative gel technology incorporated into the foam.

The Memaflex cushion is a high density cushion. The temperature sensitive visco-elastic foam moulds to the shape of the body providing greater weight distribution and pressure reduction.

CODE 2002150001

MAXIMUM WEIGHT LIMIT 24 stones / 152 kgs

RISK FACTOR Medium Risk

WARRANTY 2 years

CUSHION DIMENSIONS 17” x 17” x 4”

CUSHION WEIGHT 2 kgs

CODE 2002240001

MAXIMUM WEIGHT LIMIT 20 stones / 127 kgs

RISK FACTOR Medium to High Risk

WARRANTY 2 years

CUSHION DIMENSIONS 17” x 17” x 4”

CUSHION WEIGHT 3 kgs

CODE 2002130002

MAXIMUM WEIGHT LIMIT 20 stones / 127 kgs

RISK FACTOR High Risk

WARRANTY 2 years

CUSHION DIMENSIONS 17” x 17” x 3”

CUSHION WEIGHT 3 kgs

CODE 2002140001

MAXIMUM WEIGHT LIMIT 20 stones / 127 kgs

RISK FACTOR High Risk

WARRANTY 2 years

CUSHION DIMENSIONS 17” x 17” x 3”

CUSHION WEIGHT 3 kgs

2425

Dynamic Mattresses

A dynamic mattress support system is

developed to relieve pressure through

alternating air cells – removing interface

pressure.

Inflation / deflation of cells – works

using a pump unit (features vary)

2627

Phase III

DIMENSIONS SAFETY STANDARDS

35 x 24 x 12.5cm Complies to IEC60601-1

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN

1001010001 39 stones / 247 kgs Very High Risk* 2 years 190 x 88 x 20cm 10 minutes 20 figure of 8 cells (3 static head cells)

VERY HIGH RISK

Support Surface » The easy access, simple to use

CPR facility tag allows rapid deflation of the mattress

» Entire mattress cell system can be removed and laundered

» Waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide

» Heavy duty endurance fabric base sheet reduces possibility of damage from bed frame whilst prolonging the longevity of the mattress

» Static head section to reduce motion sickness for patients

» Securing straps provide added stability and ensures the mattress is kept in position on the bed frame

» Range of purchase, lease and hire options

» Simple transport mode for ease of use

Power Unit » Lightweight yet durable pump with in-

built sound and vibration reduction for whisper quiet operation

» A 10 minute start-up static mode allows time to position and prepare the patient

The Phase III Mattress Replacement System incorporates the latest in innovative features to help deliver the optimum care, treatment and prevention of pressure ulcers. Designed for patients at a Very High Risk of developing pressure ulcers, this mattress is suitable for both lighter and heavier individuals without compromising patient comfort.

Figure of 8 cell constructionDigital pumpon the support surface, whilst the timed static switch aids moving, handling and nursing procedures

» Dual compressors for rapid inflation and efficient operation

» Patient readiness indicator – LED continues to flash until system is fully inflated and patient ready

» The simple, easy to use control panel offers choice of Light, Medium and Heavy dependent on patient morphology

» Auto lock out feature prevents unauthorised use of settings

» Self diagnostic alarm bypass is incorporated to avoid unnecessary engineer visits

2829

Ambience

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN

1001020001 31.5 stones / 200 kgs Very High Risk* 2 years 200 x 90 x 20.3cm N/A Air Loss

DIMENSIONS SAFETY STANDARDS

15.8 x 38 x 26.8 cm CE, cUL

VERY HIGH RISK “A Low Air Loss Mattress Replacement System”

Support Surface » Entire mattress cell system (excluding

foam) can be removed and laundered which aids decontamination protocols

» Detachable, waterproof, multi stretch, vapour permeable PU cover, impregnated with Actifresh biocide reduces shear and friction forces whilst aiding infection control

» Heat sealed seams and integral, covered hoses reduce the possibility of fluid ingress to aid infection control

» Heavy duty nylon base sheet reduces possibility of damage from bed frame whilst prolonging the longevity of the mattress

» 5.1 cm layer of CMHR foam base provides added support whilst acting as the emergency pressure dispersion in case of power failure

» Differential pressure zones in the head, torso and foot sections provide optimum pressure relief by maximising the contact area and reducing pressure around bony prominences

» Automatic fowler boost provides additional support for the patient whilst in semirecumbent position

The Ambience is a Low Air Loss Mattress Replacement System equipped with a multi-functional pump unit. It has been designed to deliver effective pressure relief for patients at Very High Risk of developing pressure ulcers.

Specialist air vent holes in the cells provide maximum air circulation through the three differing pressure zones, in the head, torso and foot sections of the mattress. These encourage an increased contact area and reduce pressure around the vulnerable bony prominences, thus enhancing patient comfort and further aiding wound management.

Such versatility and sophistication ensures the Ambience System is suitable for use in both the acute hospital and homecare environments, allowing multiple nursing procedures to take place.

» Adjustable comfort control suits all individual patient needs » 25cm segmented side bolsters

enhance patient safety by providing additional support on a raised bed frame

» Cardiac arrest procedure, simply disconnect the hose at the pump to deflate the mattress to aid CPR procedures

» Max firm mode provides a firm support surface for a healthcare professional to work on

» Vacuum storage mode allows for quick storage within 5 minutes

» Range of purchase, lease and hire options to suit all customer requirements

Power Unit » Simple control panel offers 10

varying comfort levels, suitable for all nursing requirements and procedures

» Easy to clean power unit and tactile panel combines ease of use with a smooth wipe clean surface

» Auto 3 minute panel lock out prevents unauthorised setting changes

» Easy access air filter Increases efficiency and reliability whilst aiding infection control

» Audible and visual alarms Indicates low pressure and power failure in dual format

» Power cord storage and versatile hanger for easy storage

Specialist air cells Digital pump

3031

Elite

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN

1001040001 (Digital Pump) 30 stones / 190 kgs Very High Risk* 2 years 188 x 89 x 17.5cm 10 minutes 16 individual cells

1001040003 (Dial Pump) 25 stones / 159 kgs Very High Risk* 2 years 188 x 89 x 17.5cm 10 minutes 16 individual cells

DIMENSIONS SAFETY STANDARDS

29.1 x 20 x 11.7 cm IEC60601-1

VERY HIGH RISK

Support Surface » Entire mattress cell system (excluding

foam) can be removed and laundered which aids decontamination protocols

» Waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide reduces shear and friction forces whilst aiding infection control

» High frequency welded seams and integral covered hoses reduces possibility of fluid ingress to aid infection control

» Heavy duty endurance fabric base sheet reduces possibility of damage from bed frame whilst prolonging the longevity of the mattress

» Available in 3 lengths to facilitate all patient requirements. A bed extension piece is also available

» 5cm layer of visco-elastic foam base provides added support whilst acting as the emergency pressure dispersion in case of power failure

» Independent cell construction means all cells can be individually replaced to help reduce ongoing costs

» Securing straps provide added stability and ensures that the mattress is kept in position on the bed frame

» Simple transport mode and static mattress facility is included for ease. Simply connect the hoses together

» Range of purchase, lease and hire options to suit all customer requirements

Dial Pump Unit » Constructed of a strong,

lightweight and durable casing » Simple control panel offers

choice of varying comfort levels from soft to firm » Easy to clean power unit » Location of conventional fuses

on the outside of pump » Normal pressure light » Audible and visual alarm

Digital Pump Unit » Adjustable weight guidelines

ensures optimum pressure relief by automatically adjusting the mattress pressure according to the selected patient weight » Constructed of a strong, lightweight

and durable casing promoting product longevity

» Easy to clean power unit and tactile panel combines ease of use with a smooth wipe clean surface ensuring no harbouring of pathogens to aid infection control, unlike traditional dials and switches

» Location of conventional fuses on the outside of pump minimises disruption and down time

» Auto 5 minute panel lock out prevents unauthorised setting changes

» Normal pressure light Illuminates once the mattress is at appropriate pressure

» Mattress hose connection is situated within a recess in the pump to protect the hose connection from damage

» Audible and visual alarm indicates low pressure and power failure in dual format to aid effective troubleshooting

» Service light illuminates if the pump detects when a service is required

With a fully encased layer of visco-elastic foam beneath the cells for added support, the Elite mattress combines a comfortable support surface with alternating therapy. This mattress has been designed for patients at Very High Risk of developing pressure ulcers.

Unique weight setting technologyincorporated into the pump unit adjusts the cell pressure within the mattress, according to the selected patient weight.

Dial Pump Digital Pump

3233

Simple Air

DIMENSIONS SAFETY STANDARDS

28 X 20 X 15cm BS en 60601-1

MEDIUM TO HIGH RISK

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN

1001270001 28.3 stone / 180kg Medium to High Risk 1 years 200 x 90 x 20cm 10. 1S. 20. 25 minutes 16 individual cells

Support Surface » Side by side CPR tags deflate

the mattress » Independent cell construction means

all cells can be individually replaced to help reduce ongoing costs

» Fully welded seams and white inner substrate aids compliance to infection control guidelines

» Static head section reduces the chances of a patient suffering from motion sickness

» Autofirm setting provides a firm support to assist with nursing procedures

» Full length hose sleeve aids infection control protocols

» 360’ zip Aids decontamination protocols and replacement costs

The Simple Air Mattress Replacement System is a cost-effective support surface used for the prevention and treatment of pressure ulcers.

Designed for patients that are at Medium to High Risk of developing pressure ulcers, the Simple Air Mattress is suitable for use in both nursing and home care settings.

Power Unit » Strong, lightweight and durable pump

combines ease of use with a smooth wipe clean surface

» External conventional fuse minimises disruption and downtime

» Adjustable weight setting ensures optimum pressure relief by adjusting the mattress pressure to the selected patient weight

» Adjustable dynamic cycle times (10, 15, 20, 25 mins) caters for diverse nursing requirements and procedures

» Adhesive pads minimise vibration against the bed & enhances the experience of the patient

» Audible and visual alarm indicates low pressure and power failure in dual format to aid effective troubleshooting and minimise downtime

Independent cell construction Digital pump

“Cost effective support surface’”

3435

Delta Plus

VERY HIGH RISK

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN

1001050001 70 stones / 350 kgs Very High Risk* 2 years 196 x 107 x 20cm Variable 20 individual double cells

DIMENSIONS SAFETY STANDARDS

37 x 27 x 13cm IEC60601-1

Support Surface » Entire mattress cell system can

be removed and laundered to aid decontamination protocols

» Detachable, waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide reduces shear and friction forces whilst aiding infection control

» Heat sealed, stiched cover reduces possibility of fluid ingress to aid infection control

» Heavy duty nylon base sheet reduces possibility of damage from bed frame whilst prolonging the longevity of the mattress

» Independent cell construction means that all cells can be individually replaced to help reduce on-going costs » Integral and covered hoses reduces

the possibility of fluid ingress to aid infection control

» Easy access and simple to use CPR tags allows for rapid deflation of the mattress to aid emergency procedures

» Adjustable comfort control to suit all individual patient needs

» Autofirm Setting Provides a firm support surface for a healthcare professional to work on. If not overridden manually this will automatically revert to therapy mode after 20 minutes

The Delta Plus Mattress Replacement System provides alternating pressure relief for the heavier individual.

Suitable for patients up to 70 stone (350 kgs), the Delta Plus is designed for both the prevention and treatment of pressure ulcers, suitable for patients up to Very High Risk.

» 4 adjustable cycle settings of 10, 15, 20, 25 minutes ensures differing nursing requirements and procedures

» Semi-recumbent setting increases the internal cell pressure by 10% to accommodate the semi-recumbent position thus allowing the patient to sit up in bed

» Range of purchase, lease and hire options to suit all customer requirements

Power Unit » Constructed of a strong, lightweight

and durable casing that promotes product longevity » Simple control panel offers choice of

varying comfort levels suitable for all nursing requirements and procedures

» Easy to clean power unit and tactile panel combines ease of use with a smooth wipe clean surface to aid infection control

» Location of conventional fuses on the outside of pump minimises disruption and down time

» Manual lock out prevents unauthorised setting changes

» Easy access air filter increases efficiency and reliability whilst aiding infection control

» Audible and visual alarm indicates low pressure in dual format

Digital pump Independent cell construction

“Suitable for patients up to 70 stones / 350 kgs”

3637

Eclipse II

MEDIUM TO HIGH RISK

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN

1001060003 30 stones / 190 kgs Medium to High Risk* 2 years 188 x 88 x 12cm 10 minutes 16 individual double cells

DIMENSIONS SAFETY STANDARDS

29.1 x 20 x 11.7cm IEC 601/1 BS5724 Part 1

“Suitable in both the prevention and treatment of pressure ulcers”

Support Surface » Entire mattress cell system can

be removed and laundered to aid decontamination protocols

» Waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide reduces shear and friction forces whilst aiding infection control

» Integral and covered hoses reduces the possibility of fluid ingress to aid infection control » Heavy duty endurance fabric base

sheet reduces possibility of damage from bed frame whilst prolonging the longevity of the mattress

» Facilitates all patient requirements. An bed extension piece is also available » Independent cell construction means

all cells can be individually replaced to help reduce ongoing costs

» Securing straps provide added stability and ensure the overlay is kept in position on the mattress

» Simple transport mode and static mattress facility is included for ease. Simply connect the hoses together

» Range of purchase, lease and hire options to suit all customer requirements

The Eclipse II Mattress Overlay System is a highly efficient, yet cost effective alternating mattress suitable in both the prevention and treatment of pressure ulcers.

Easy to install and operate the Eclipse II is suitable for Medium to High Risk patients in both hospital and homecare environments.

Power Unit » Adjustable weight guidelines

ensures optimum pressure relief by automatically adjusting the mattress pressure according to the selected patient weight (Digital Pump only)

» Constructed of a strong, lightweight and durable casings to promote product longevity

» Easy to clean power unit and tactile panel combines ease of use with a smooth wipe clean surface to aid infection control

» Location of conventional fuses on the outside of pump minimises disruption and down time

» Auto 5 minute panel lock out prevents unauthorised setting changes

» Normal pressure light illuminates once the mattress is at appropriate pressure

» Mattress hose connection is situated within a recess in the pump to protect the hose connection from damage

» Audible and visual alarm indicates low pressure and power failure in dual format to aid effective troubleshooting and minimise downtime

» Service light illuminates if the pump requires a service to reduce potential downtime

Digital PumpDial Pump

3839

Double Plus

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN

1001080001 22 stones / 140 kgs (on each side) Very High Risk* 2 years 198 x 137 x 15cm 9.5 minutes 14 individual double cells

DIMENSIONS SAFETY STANDARDS

12.5 x 8.5 x 25cm IEC60601-1

“Promoting the continuation of care and lifestyle for the patient and their partner”

Support Surface » Entire mattress cell system (excluding

foam) can be removed and laundered to aid decontamination protocols

» Waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide reduces shear and friction forces whilst aiding infection control

» Heat sealed, stitched cover reduces possibility of fluid ingress to aid infection control

» Adjustable comfort control to suit all individual patient needs

» Range of purchase, lease and hire options to suit all customer requirements

The Double Plus System combines alternating therapy and a static foam mattress to provide optimum pressure relief whilst promoting the continuation of care and lifestyle for the patient and their partner.

The choice of which side of the mattress alternates means the Double Plus can be tailored to accommodate individual patient lifestyles.

Suitable for patients who are at Very High Risk of developing pressure ulcers the manually adjustable cell pressure controls ensure that adequate support and pressure relief is maintained and quality of sleep is enhanced.

Power Unit » Simple control panel offers choice of

varying comfort levels to suit all nursing requirements and procedures

» Easy to clean power unit with smooth wipe clean surface helps aid infection control

Alternating cellsDial pump

VERY HIGH RISK

4041

Genesis

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN

1001090001 4.5 stones / 28.6 kgs Very High Risk* 2 years 122 x 65 x 11cm 9.5 minutes 18 individual double cells

DIMENSIONS SAFETY STANDARDS

12.5 x 8.5 x 25cm IEC60601-1

VERY HIGH RISK

“Suitable for the younger patient”

Support Surface » Entire mattress cell system (excluding

foam) can be removed and laundered to aid decontamination protocols

» Waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide reduces shear and friction forces whilst aiding infection control

» Heat sealed, stitched cover reduces possibility of fluid ingress to aid infection control

» Simple transport mode and static mattress facility is included for ease. Simply connect the hoses together

» Range of purchase, lease and hire options to suit all customer requirements

The Genesis Paediatric Mattress Replacement System uses the accepted principles of alternating pressure to assist in both the prevention and treatment of pressure ulcers in either a cot or nursery bed.

Suitable for the younger patient, the Genesis Mattress is both easy to install and operate, making it suitable for both hospital and homecare environments.

Power Unit » Constructed of a strong,

lightweight and durable casing to promote product longevity

» Easy to clean power unit combines ease of use with a smooth wipe clean surface to aid infection controlCell system Pump unit

4243

Eclipse Cushion

CODE RISK FACTOR WARRANTY CUSHION DIMENSIONS CUSHION WEIGHT

1002100001 High Risk 2 years 43cm x 43cm x 10cm 2 kgs

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY CUSHION DIMENSIONS CUSHION WEIGHT

1002070001 15 stones / 100 kgs Medium Risk 2 years 43cm x 43cm x 7.5cm 2 kgs

» White inner substrate (underside of the cover) helps auditing procedures by making staining easy to identify » High frequency welded seams,

fully enclosed zip and integral covered hoses help to reduce the risk of fluid ingress » The entire cushion cell system

(excluding foam base) and cover can be completely removed and laundered up to 80°C to aid decontamination protocols

» White inner substrate (underside of the cover) helps auditing procedures by making staining easy to identify » High frequency welded seams,

fully enclosed zip and integral covered hoses help to reduce the risk of fluid ingress » The entire cushion cell system

(excluding foam base) and cover can be completely removed and laundered up to 80°C to aid decontamination protocols

The multi stretch PU cover is waterproof, vapour permeable and impregnated with Acti-fresh biocide to help prevent the build up of bacteria and ensure it can be easily cleaned to aid disinfection protocols.

The multi stretch PU cover is waterproof, vapour permeable and impregnated with Acti-fresh biocide to help prevent the build up of bacteria and ensure it can be easily cleaned to aid disinfection protocols.

Prelude Cushion

MEDIUM RISK

Dial pump, Maximum Weight Limit 25 stones / 159kgs

Digital Pump, Maximum Weight Limit 30 stones / 191kgs

HIGH RISK

Dial pump

4445

Hybrid Mattresses

A hybrid mattress is a combination of high specification foam and alternating air cells –

one support surface that redistributes and relieves

interface pressures.

Air Cells

FoamCore

4647

Hybrid-Power

“High specification foam combined with alternating cells”

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR MATTRESS DIMENSIONS OPERATING CYCLE

1001290001 40 stones / 254 kgs Up to High Risk* 1980 x 880 x 160mm 10 minutes

DIMENSIONS SAFETY STANDARDS

254 x 130 x 95 mm Tested to IEC60601-1

UP TO HIGH RISK

The Hybrid-Power mattress combines the pressure redistribution properties of high specification foam, with alternating pressure relief.The visco-elastic foam conforms to the shape of the body, while the alternating cells assist with pressure relief. There is no requirement to move the patient off the bed to step them up to an alternating system or step them down to a static mattress.

White inner substrate Digital pump

Support Surface » Cover can withstand a higher

concentration of cleaning substances and offers greater resistance to abrasion

» High frequency welded seams protect against fluid ingress

» 360° zip to prolong longevity » Automatic lock out feature » Low pressure alarm and indicator » Non-slip base - prevents the mattress

from sliding out of position, giving reassurance to the patient and carer

» Base sheet - prevents fluid ingress » White inner substrate makes fluid

ingress becomes easily identifiable to aid infection control guidelines

» Turning pillow provides additional comfort

» High specification foam combined with alternating cells

» Castellated side formers to prolong longevity

» Zonal mattress surface gives additional support to vulnerable areas

Power Unit » Easy to use with no requirement

to move the patient out of bed when stepping them up to the alternating mode

» Compact and light weight power unit » Power failure alarm and indicator

4849

Hybrid-Turn

“Combines both static and alternating therapy thus only one support surface is required”

CODE MAXIMUM WEIGHT LIMIT RISK FACTOR MATTRESS DIMENSIONS OPERATING CYCLE FOAM & COVER WARRANTY PUMP WARRANTY

1001280001 254kg / 40st Up to High Risk 1980 x 880 x 160mm 10, 15, 20, 25 mins 5 years 2 years

The Hybrid-Turn mattress is a unique hybrid concept. This mattress offers the traditional benefits of high specification visco-elastic foam and true alternating therapy by simply rotating the mattress. Suitable for patients weighing up to 254kg / 40st who are at high risk of developing pressure ulcers.

Alternating Side (Step Up) Static Side (Step Down)

In one easy turn, this mattress allows for immediate step down or step up to a full body length alternating surface. Individually removeable cells allow components to be individually replaced or cleaned.

Alternating Side (Step Up) » Ideal for use in Community and

Nursing Home environments » Mattress best practice guidelines

clearly printed on the cover » Cover and foam can be

replaced individually » Also available in a bariatric,

paediatric and double size mattress

Static Side (Step Down) » High specification visco-elastic

foam conforms to the body, reducing the pressure for effective pressure elcer prevention » Suitbale for up to Category

2 pressure ulcers

Sodium Hypochlorite Resistant Cover » Can withstand higher concentration

of cleaning substances » Offers greater resistance to abrasion

» High frequency welded seams protect against fluid ingress » 360° zip to prolong longevity » White inner substrate to aid

infection control guidelines Power Unit » Auto lock out function prevents

any unauthorised setting changes to the pump unit

» Automatic shut off valves in the pump unit prevent the mattress from deflating during power failures allowing the mattress to retain static pressure for up to 24 hours » 20 minute timed static mode

allows the carer enough time to position or prepare the patient on a firm support surface before automatically reverting back to alternating mode

DIMENSIONS SAFETY STANDARDS

254 x 130 x 95 mm Tested to IEC60601-1

HIGH RISK

Digital pump

5051

Notes

52

Leaflet Code: LL237For more information contact your local dealer:

All sizes and weights stated are nominal. All errors and omissions excepted. Due to the limitations of photography and the printing process colours shown may not be 100% accurate. *All equipment should be used in conjunction with clinical judgement and assessments dependent

on individual patient morphology. Essential nursing care is pivotal in providing the optimum pressure ulcer prevention plan.

www.drivedevilbiss.co.uk