Voltage Measurement range Available fluid Repeatability accuracy Temp. accuracy Operating Temp. range Output Residual voltage Air pressure setting Leakage current Storage Temp. range DC24V±10% DC12~24V±10% air、non-corrosive gas、non-flammable gas ±0.7% F.S. ±2.5%F.S. 0~60℃ 5~40mA 5.5V Max. An intelligent learning button 1.0mA Max. -20~75℃ Model DPC DPCN DPCP DPC10:-100kPa~1000kPa ; DPC01:-100kPa~100kPa 30V/100mA Max. 0.7V Max. Port size of connector Special function ø4mm,ø6mm,ø1/4" Precautions Specifications 1.Do NOT drop, beat or apply excessive impact on DPC. Otherwise, it may cause serious damage. 2.The tensile strength of the cable is 30N. Exerting a greater tension force on it may cause serious damage. 3.Do NOT use it with corrosive, flammable gas or liquid. 4.Do NOT wire the cable of DPC with other power cables or high-voltage cables. 5.If DPC is applied with a load, such as relay or magnetic valve, that would induce emf, an additional voltage absorption component like reverse bias diode should be applied. Hysteresis <2%F.S. DPC Series Digital Pressure Check Circuit example Brown Blue Black Load Power NPN Brown Blue Black Load Power PNP Brown Blue Load Power 2-Wire Installation notes 1.The pneumatic pipe should be insert into a connector firmly. 2.Ensure no air leakage by ventilating desired air pressure. 3.Follow the instruction below for pressure setting. Dimension 36.1 30.5 29.5 9.5 Set button Pneumatic pipe Enclosure classification IP40 Circuit protection Reverse polarity protection、surge protection 1: If the power supply for 2-wire type DPC is less than DC20V, the leakeage current would be greater than 1mA. Therefore, PLC may react incorrectly. 2: If a relay is used as a switch for power supply, an additional capacitance should be connected between V+ and ground so as to suppress inrush current. (The capacitance is recommended to be greater than 100μF under 50 Volt.) 1.air pressure memorization 2.N.O./N.C. mode switch (default: N.O. mode) Ordering code DPC 01: -100kPa~100 kPa 10: -100kPa~1000kPa Output type Blank:2-wire N:NPN P:PNP D4: ø4mm D6: ø6mm 08: ø1/4" Measurement range Port size of connector Length of wire 020: length of wire is 2m 030: length of wire is 3m 050: length of wire is 5m

DPC Series - AirTAC

  • Upload
    others

  • View
    27

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DPC Series - AirTAC

Voltage

Measurement range

Available fluid

Repeatability accuracy

Temp. accuracy

Operating Temp. range

Output

Residual voltage

Air pressure setting

Leakage current

StorageTemp. range

DC24V±10% DC12~24V±10%

air、non-corrosive gas、non-flammable gas

±0.7% F.S.

±2.5%F.S.

0~60℃

5~40mA

5.5V Max.

An intelligent learning button

1.0mA Max.

-20~75℃

Model DPC DPCN DPCP

DPC囗10:-100kPa~1000kPa ; DPC囗01:-100kPa~100kPa

30V/100mA Max.

0.7V Max.

Port size of connector

Special function

ø4mm,ø6mm,ø1/4"

Precautions

Specifications

1.Do NOT drop, beat or apply excessive impact on DPC. Otherwise, it may cause serious damage.2.The tensile strength of the cable is 30N. Exerting a greater tension force on it may cause serious damage.3.Do NOT use it with corrosive, flammable gas or liquid.4.Do NOT wire the cable of DPC with other power cables or high-voltage cables.5.If DPC is applied with a load, such as relay or magnetic valve, that would induce emf, an additional voltage absorption component like reverse bias diode should be applied.

Hysteresis <2%F.S.

DPC SeriesDigital Pressure Check

Circuit example

Brown

Blue

Black

Load

PowerNPN

Brown

Blue

Black

Load

PowerPNP

Brown

Blue

Load

Power2-Wire

Installation notes1.The pneumatic pipe should be insert into a connector firmly.2.Ensure no air leakage by ventilating desired air pressure.3.Follow the instruction below for pressure setting.

Dimension

36.1

30.5

29.5

9.5

Set button

Pneumatic pipe

Enclosureclassification IP40

Circuit protection Reverse polarity protection、surge protection

1: If the power supply for 2-wire type DPC is less than DC20V, the leakeage current would be greater than 1mA. Therefore, PLC may react incorrectly.2: If a relay is used as a switch for power supply, an additional capacitance should be connected between V+ and ground so as to suppress inrush current. (The capacitance is recommended to be greater than 100μF under 50 Volt.)

1.air pressure memorization2.N.O./N.C. mode switch (default: N.O. mode)

Ordering code

DPC 囗 囗 囗 囗

01: -100kPa~100 kPa 10: -100kPa~1000kPa

Output type

Blank:2-wire

N:NPN P:PNP

D4: ø4mmD6: ø6mm 08: ø1/4"

Measurement range Port size of connectorLength of wire

020: length of wire is 2m030: length of wire is 3m050: length of wire is 5m

Page 2: DPC Series - AirTAC

LED explanation Instruction

Continuous light

Twinkle(10 times/sec)

Twinkle(1 times/sec)

Twinkle(3 times/sec)

LED state DPC state

LED state DPC state

LED state DPC state

Red LED(sustain 1 second):N.O. mode Green LED(sustain 1 second):N.C. mode

Red LED:(N.O mode)Measured pressure>setting pressureGreen LED:(N.C mode)Measured pressure<setting pressure

Red LED:(N.O mode)Measured pressure<setting pressureGreen LED:(N.C mode)Measured pressure>setting pressure

Simple mode

LED state DPC state

Red LED(sustain 1 second):N.O. mode Green LED(sustain 1 second)N.C. mode

Mid Value

Red LED:N.O mode Green LED:(N.C mode)

Ready for pressing

Red LED:(N.O mode)Measured pressure>setting pressureGreen LED:(N.C mode)Measured pressure<setting pressure

Red LED:(N.O mode)Measured pressure<setting pressureGreen LED:(N.C mode)Measured pressure>setting pressure

Pressure setting complete

Pressure setting complete

Pressure out of limit warning

Initial state

Red and Green LED twinkling alternately: pressure setting out of limitation of specification

Red and Green LED twinkling alternately: DPC is ready for setup.

press the button < 2 seconds

pressure the button for 2~5 seconds

setting completesetting value=

pressure at present

Green LED(sustain 1 second)

record pressure A=pressure at present PI

Green LED

press the button once

setting value=(pressure A+pressure B)/2

press the button >10 seconds.

N.O. mode

Red LED

Red LED

N.C. mode

Green LED

press the button for 6~10 seconds

N.C. mode

Red LED(sustain 1 second)

N.O. mode

N.C. modeRed LED

N.O. mode

Note: pressure of out limit warningIf the value of pressure seeting is beyond the scope of the limitation of specification, the red and green LED would twinkle alternately.Please rest the value appropriately.

Simple mode setting Mid value mode

Green LED

pressure at present

Waiting for recording pressure B

pressure at present PI

pressure at present PⅡ

record pressure B=pressure at present PⅡ

N.O./N.C. mode switch

measured pressure>setting pressure

1.Lock:It will be locked automatically as long as it is on standby for more than 120 seconds.2.Unlock:press the button for 2 seconds.

Lock

Unlock

press the button < 2 seconds

◆Quick examination for "lock state"

whether the red and green LED shine at the same time

No

Yes

Lock/Unlock mode

Reset

pressure settingvalue

N.O./N.C. mode

Lock/Unlock

default

0kPa

N.O.

Unlock

measured pressure<setting pressure

Green LED(sustain 1 second)

N.C. mode

Red LED(sustain 1 second)

N.O. mode

Green LED(sustain 1 second)

N.C. mode

Red LED(sustain 1 second)

N.O. mode

measured pressure<setting pressure

measured pressure>setting pressure

Page 3: DPC Series - AirTAC

Output signal explaination

red LEDN.O.

kPa

80

40

0

-40

t

continuous light (output ON)

twinkle slowly (output OFF)

pressure setting value

Simple mode

kPa

80

40

0

-40

t

Mid value mode- It has an application for investigating whether the target is been sucked or not.

-Investigating the pressure with and without target being sucked respectively. It will calculate and set the mid value automatically.

press the button for 2~5 seconds

press the button

target no target

Mid value

green LEDN.C.

continuous light (output ON)

twinkle slowly (output OFF)

continuous light (output ON)

twinkle slowly (output OFF)

continuous light (output ON)

twinkle slowly (output OFF)

red LEDN.O.

green LEDN.C.

pressure setting value