60"LONG
46"TALL 46"
TALL
44"WIDE
HOPKINS, MI
HOPKINS, MICHIGAN 49328
SIGNED DATE
NOT APPROVED COMMENTS
APPROVED AS MARKED
APPROVED AS SHOWN
PRINT APPROVAL REQUEST
SP INDUSTRIES
49"PIT
24" 41'-4-11/16" REF.
63-1/2"
39-5/8" 42"
86-1/2" 4"
90-1/2"
6"REINFORCEDCONCRETE
82-7/16"SWING OUT
9'-8"MIN.
HEIGHT
37"
TYP. 40 CU. YD. COMPACTION CONTAINERFORCE RATING MUST MEET OR EXCEED 85,000#
REAR-LOAD HOPPER
ROLO-4000-48
CP-4101-HD
CUT LEGS DOWN TO MATCH PIT HEIGHT
PINNING TUNNEL
84"DECK 71-1/4" 47"
60"
90-1/2"
79-3/4"
17'-6"PIT DEPTH 8" 22'-10"
120"PIT
WIDTH
THRU-WALL BINDERS(BOTH SIDES)
CENTERING GUIDE ISLAND
PIT DECK CLOSURE PANELS(BY OTHERS)
7'-0" WIDE 10,000# CAPACITY DECKw/ 24" EXTENSION
POWER UNIT(OPTIONAL LOCATION)
DISCONNECTBY OTHERS
CONTROLS
PINNING CONTROLS(MOUNTED OUTSIDE)
47"
120"DOOR & PITOPENING
49"PIT
47"
120"DOOR
OPENING
OPENINGCLOSURE PANELS
DISCONNECTBY OTHERS
POWER UNIT(OPTIONAL LOCATION)
*CUSTOMER'S CARTFOR ACCURATE BUILD OF DUMPERPLEASE SHIP CARTS TO SP-INDUSTRIES ORPROVIDE ACCURATE AND DETAILED DRAWINGSOF CARTS.
TABLE 1 DISCONNECT & VARIABLE COMPONENTSCOMPONENT VALUES MARKED WITH ASTERISK *) ARE RECOMMENDED
VALUES ONLY FOR A 20HP & 10HP MOTOR. INSTALLING CONTRACTOR MUST CONSULT ALL LOCAL CODES FOR CONFORMITY.
VOLTAGE 3 -VAC
FULL LOAD MTR. CURRENT- AMP
SIZE OF *) DISCONNECT
SIZE OF *) FUSES (AMP)
RECOMM. *) WIRE SIZE
208 90.2 200 125.0 2230 82.0 100 100.0 3460 41.0 60 50.0 8
PROPOSED THRU-WALL INSTALLATION OF A CP-4101-HD WITH REAR-LOAD HOPPER FED BY A ROLO-4000-48 DUMPING CUSTOMER'S CART
TITLE:TOLERANCESFRAC. 1/16.XX .015.XXX .005
CHECKED BY:
JOB NO:
REV:
SYM. CHANGE OR REVISION DATE BY
#
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SP INDUSTRIES, INC. AND EMBODIES A CONFIDENTIAL PROPRIETARY DESIGN.SP INDUSTRIES INC. RESERVES ALL PROPRIETARY RIGHTS IN THIS DRAWING AND IN THE SUBJECT MATERIAL AND INVENTIONS DISCLOSEDTHEREIN, INCLUDING THE EXCLUSIVE RIGHT TO USE THE DRAWING FOR ALL PURPOSES. THIS DRAWING IS SUBMITTED UNDER ACONFIDENTIAL RELATIONSHIP FOR A SPECIFIC PURPOSE, AND THE RECIPIENT AGREES, BY ACCEPTING THIS DRAWING TO, NOT TOALLOW THIS DRAWING TO BE REPRODUCED OR TO SUPPLY OR DISCLOSE ANY INFORMATION REGARDING THIS DRAWING OR THESUBJECT MATTER THEREOF TO ANY OTHER PERSON WITHOUT THE EXPRESS WRITTEN CONSENT OF SP INDUSTRIES, INC.
1 OF 3
USED ON:SALES PROPOSAL
BUILD:CP-4101-HD
SHEET:WEIGHT:
TEMPLATE SIZE:D
C. JOHNSONDRAWN: DATE:
11/17/2017
1:30SCALE:
DP-27477DRAWING NO:
60"LONG
46"TALL 46"
TALL
44"WIDE
HOPKINS, MI
HOPKINS, MICHIGAN 49328
SIGNED DATE
NOT APPROVED COMMENTS
APPROVED AS MARKED
APPROVED AS SHOWN
PRINT APPROVAL REQUEST
SP INDUSTRIES
49"PIT
24" 41'-4-11/16" REF.
39-5/8" 42"
86-1/2" 4" 90-1/2"
6"REINFORCEDCONCRETE
82-7/16"SWING OUT
9'-8"MIN.
HEIGHT
37"
TYP. 40 CU. YD. COMPACTION CONTAINERFORCE RATING MUST MEET OR EXCEED 85,000#
REAR-LOAD HOPPER
ROLO-4000-48
CP-4101-HD
CUT LEGS DOWN TO MATCH PIT HEIGHT
PINNING TUNNEL
84"DECK 71-1/4"
17'-6"PIT DEPTH 8" 22'-10"
120"PIT
WIDTH
THRU-WALL BINDERS(BOTH SIDES)
CENTERING GUIDE ISLAND
PIT DECK CLOSURE PANELS(BY OTHERS)
7'-0" WIDE 10,000# CAPACITY DECKw/ 24" EXTENSION
POWER UNIT(OPTIONAL LOCATION)
DISCONNECTBY OTHERS
CONTROLS
PINNING CONTROLS(MOUNTED OUTSIDE)
47"
120"DOOR & PITOPENING
49"PIT
47"
120"DOOR
OPENING
OPENINGCLOSURE PANELS
DISCONNECTBY OTHERS
POWER UNIT(OPTIONAL LOCATION)
*CUSTOMER'S CARTFOR ACCURATE BUILD OF DUMPERPLEASE SHIP CARTS TO SP-INDUSTRIES ORPROVIDE ACCURATE AND DETAILED DRAWINGSOF CARTS.
TABLE 1 DISCONNECT & VARIABLE COMPONENTSCOMPONENT VALUES MARKED WITH ASTERISK *) ARE RECOMMENDED
VALUES ONLY FOR A 20HP & 10HP MOTOR. INSTALLING CONTRACTOR MUST CONSULT ALL LOCAL CODES FOR CONFORMITY.
VOLTAGE 3 -VAC
FULL LOAD MTR. CURRENT- AMP
SIZE OF *) DISCONNECT
SIZE OF *) FUSES (AMP)
RECOMM. *) WIRE SIZE
208 90.2 200 125.0 2230 82.0 100 100.0 3460 41.0 60 50.0 8
PROPOSED THRU-WALL INSTALLATION OF A CP-4101-HD WITH REAR-LOAD HOPPER FED BY A ROLO-4000-48 DUMPING CUSTOMER'S CART
TITLE:TOLERANCESFRAC. 1/16.XX .015.XXX .005
CHECKED BY:
JOB NO:
REV:
SYM. CHANGE OR REVISION DATE BY
#
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SP INDUSTRIES, INC. AND EMBODIES A CONFIDENTIAL PROPRIETARY DESIGN.SP INDUSTRIES INC. RESERVES ALL PROPRIETARY RIGHTS IN THIS DRAWING AND IN THE SUBJECT MATERIAL AND INVENTIONS DISCLOSEDTHEREIN, INCLUDING THE EXCLUSIVE RIGHT TO USE THE DRAWING FOR ALL PURPOSES. THIS DRAWING IS SUBMITTED UNDER ACONFIDENTIAL RELATIONSHIP FOR A SPECIFIC PURPOSE, AND THE RECIPIENT AGREES, BY ACCEPTING THIS DRAWING TO, NOT TOALLOW THIS DRAWING TO BE REPRODUCED OR TO SUPPLY OR DISCLOSE ANY INFORMATION REGARDING THIS DRAWING OR THESUBJECT MATTER THEREOF TO ANY OTHER PERSON WITHOUT THE EXPRESS WRITTEN CONSENT OF SP INDUSTRIES, INC.
2 OF 3
USED ON:SALES PROPOSAL
BUILD:CP-4101-HD
SHEET:WEIGHT:
TEMPLATE SIZE:D
C. JOHNSONDRAWN: DATE:
11/17/2017
1:30SCALE:
DP-27477DRAWING NO:
60"LONG
46"TALL 46"
TALL
44"WIDE
HOPKINS, MI
HOPKINS, MICHIGAN 49328
SIGNED DATE
NOT APPROVED COMMENTS
APPROVED AS MARKED
APPROVED AS SHOWN
PRINT APPROVAL REQUEST
SP INDUSTRIES
*CUSTOMER'S CARTFOR ACCURATE BUILD OF DUMPERPLEASE SHIP CARTS TO SP-INDUSTRIES ORPROVIDE ACCURATE AND DETAILED DRAWINGSOF CARTS.
TABLE 1 DISCONNECT & VARIABLE COMPONENTSCOMPONENT VALUES MARKED WITH ASTERISK *) ARE RECOMMENDED
VALUES ONLY FOR A 20HP & 10HP MOTOR. INSTALLING CONTRACTOR MUST CONSULT ALL LOCAL CODES FOR CONFORMITY.
VOLTAGE 3 -VAC
FULL LOAD MTR. CURRENT- AMP
SIZE OF *) DISCONNECT
SIZE OF *) FUSES (AMP)
RECOMM. *) WIRE SIZE
208 90.2 200 125.0 2230 82.0 100 100.0 3460 41.0 60 50.0 8
PROPOSED THRU-WALL INSTALLATION OF A CP-4101-HD WITH REAR-LOAD HOPPER FED BY A ROLO-4000-48 DUMPING CUSTOMER'S CART
TITLE:TOLERANCESFRAC. 1/16.XX .015.XXX .005
CHECKED BY:
JOB NO:
REV:
SYM. CHANGE OR REVISION DATE BY
#
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SP INDUSTRIES, INC. AND EMBODIES A CONFIDENTIAL PROPRIETARY DESIGN.SP INDUSTRIES INC. RESERVES ALL PROPRIETARY RIGHTS IN THIS DRAWING AND IN THE SUBJECT MATERIAL AND INVENTIONS DISCLOSEDTHEREIN, INCLUDING THE EXCLUSIVE RIGHT TO USE THE DRAWING FOR ALL PURPOSES. THIS DRAWING IS SUBMITTED UNDER ACONFIDENTIAL RELATIONSHIP FOR A SPECIFIC PURPOSE, AND THE RECIPIENT AGREES, BY ACCEPTING THIS DRAWING TO, NOT TOALLOW THIS DRAWING TO BE REPRODUCED OR TO SUPPLY OR DISCLOSE ANY INFORMATION REGARDING THIS DRAWING OR THESUBJECT MATTER THEREOF TO ANY OTHER PERSON WITHOUT THE EXPRESS WRITTEN CONSENT OF SP INDUSTRIES, INC.
3 OF 3
USED ON:SALES PROPOSAL
BUILD:CP-4101-HD
SHEET:WEIGHT:
TEMPLATE SIZE:D
C. JOHNSONDRAWN: DATE:
11/17/2017
1:30SCALE:
DP-27477DRAWING NO: