11
261 Covers and Frames Ductile Iron Covers and Frames 262 Ductile Iron Covers and Frames – E600 263 Ductile Iron Covers and Frames – D400 264 Ductile Iron Covers and Frames – B125 267 GripTop – D400 268 Gully Grates – D400 269 Surface Boxes 270 Steel Covers and Frames 273

download the covers and frames section of our utilities guide... · the requirements of the European Standard BS EN 124. This ... Group 2 (min Class ... D400N 600 x 600 806 x 806

Embed Size (px)

Citation preview

261

Covers and Frames

Ductile Iron Covers and Frames 262

Ductile Iron Covers and Frames – E600 263

Ductile Iron Covers and Frames – D400 264

Ductile Iron Covers and Frames – B125 267

GripTop – D400 268

Gully Grates – D400 269

Surface Boxes 270

Steel Covers and Frames 273

262 Utilities | Covers and Frames Utilities | Covers and Frames 263The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.

Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.

Ductile Iron Covers and Frames Ductile Iron Covers and Frames – E600

Standard classifications

Ductile Access covers and gully grates installed in the UK should meet the requirements of the European Standard BS EN 124. This applies to all situations, road and off-road, and to all materials. Products designed to BS EN 124 are grouped and classified depending on their place of installation.

It is the responsibility of the engineer to ensure that the correct product is specified:

“The appropriate class of access covers top or gully top to be used depends upon the place of installation. The selection of the appropriate class is the responsibility of the designer. Where there is any doubt the stronger class should be selected.” Clause 5 BS EN 124.

Quality control

Companies wishing to comply with BS EN 124 must either be independently certified to BS EN 29001 or meet strict quality control procedures stipulated within the standard.

Loading specifications

Markings and badging

All covers, gratings and frames shall bear:

BS EN 124 and the appropriate class

The name and/or identification mark of the manufacturer and the place of manufacture, which may be in code

The mark of a certification body

Additional markings required by the customer

Production identification, i.e. name or reference

Access covers are offered badged to suit your requirements.

BS EN 124 BS EN 124

Class Test Load

F900 900kN

E600 600kN

D400 400kN

C250 250kN

B125 125kN

A15 15kN

Group 1 (min Class A15) Areas which can only be used by pedestrians and pedal cyclists

Group 2 (min Class B125) Footways, pedestrian areas and comparable areas, car parks or parking decks

Group 3 (min Class C250) Full gully tops installed in the area of kerbside channels of roads which when measured from the kerb edge extend a maximum of 0.5m into the carriageway and a maximum of 0.2m into the footway

Group 4 (min Class D400) Carriageway of roads (including pedestrian streets), hard shoulders and parking areas for all types of road vehicles

Group 5 (min Class E600) Areas imposing high wheel loads e.g. docks and aircraft pavements

Group 6 (min Class F900) Areas imposing particularly high wheel loads e.g. aircraft pavements

Recommended for use in trunk roads carrying fast-moving traffic and industrial areas subject to exceptionally heavy traffic eg. dual carriageways, docks and container areas.

Recommended for use in trunk roads carrying fast-moving traffic and industrial areas subject to exceptionally heavy traffic eg. dual carriageways, docks and container areas.

Features:

Double triangular

Non-rock design

Frame lifting points

LTS installation and durability features

HA 104/2 compliant

Sewers for Adoption 6 compliant.

Options:

Badging options.

Features:

Double triangular

Non-rock design

HA 104/2 compliant

Sewers for Adoption 6 compliant

Options:

Badging options

Security locking option.

BS EN124 Loading Class

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Cover Mass (kg)

Total Mass (kg)

Open Keyways

E600 610 x 610 815 x 815 150 80* 130

Closed Keyways

E600 610 x 610 815 x 815 150 79* 130

BS EN 124 Loading Class

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Cover Mass (kg)

Total Mass (kg)

Open Keyways

E600 1210 x 685 1375 x 850 150 82* 260

E600 1825 x 685 1985 x 850 150 82* 383

Closed Keyways

E600 1210 x 685 1375 x 850 150 83* 267

E600 1825 x 685 1985 x 850 150 83* 384

* Cover mass per pair.

* Cover mass per pair.

BS EN 124 Applications

Double Triangular

264 Utilities | Covers and Frames Utilities | Covers and Frames 265The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.

Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.

Hinged Double Triangular

Ductile Iron Covers and Frames – D400 Ductile Iron Covers and Frames – D400

Recommended for use in city roads where hinged security is required.

Features:

Double triangular

Hinged cover design

Frame lifting points

LTS installation and durability features

HA 104/2 compliant

Sewers for Adoption 6 compliant.

Options:

Retro-fit security locking option (including high security version)

Badging options

Safety grid options.

Features:

Double triangular

Non-rock design

Automatic cover security locking

Semi-ergonomic hinging design

LTS installation and durability features

HA 104/02 compliant

Sewers for Adoption 6 compliant.

Options:

Badging options.

BS EN 124 Loading Class

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Cover Mass (kg)

Total Mass (kg)

D400N 600 x 450 800 x 650 100 22.3† 83.5

D400N 600 x 600 800 x 800 100 26.2† 96

D400N 675 x 675 875 x 875 100 40† 127

D400N 750 x 600 940 x 745 100 39† 118

D400N 750 x 750 905 x 940 100 43.3† 131

D400N 900 x 600 1100 x 800 100 40.7† 142

D400N 1060 x 700 1210 x 850 100 51.4† 170

D400N 1220 x 685 1380 x 885 100 38† 217

D400N 1200 x 750 1350 x 945 100 39† 217

D400N 1500 x 750 1660 x 940 100 43† 243

D400N 1800 x 750 1955 x 940 100 39† 317

BS EN 124 Loading Class

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Cover Mass (kg)

Total Mass (kg)

D400N 600 x 600 806 x 806 100 25▲ 82.5

D400N 600 x 600 806 x 806 150 25▲ 92.5

BS EN 124 Loading Class

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Cover Mass (kg)

Total Mass (kg)

D400N 600 x 600 800 x 800 150 * *

D400N 675 x 675 875 x 875 150 * *

D400N 900 x 600 1100 x 800 150 * *

D400N 1220 x 685 1380 x 885 150 * *

100mm deep units

150mm deep units

† Heaviest hinged cover.

* Available on request.

▲ Heaviest cover.

Off Mains Drainage and Separators PE and Barrier Pipe Systems Cable Protection and Access Boxes Reinforcement and Ground Movement Damp Proof and Barrier Membranes

Specialist Chemicals Hard Landscaping – Flag and Kerb Linear Channel Drainage Access Covers and Gully Gratings Street Furniture

Plastic Drainage Surface Water Drainage Flexible Couplings Stormwater Management Rainwater Harvesting

Site Start Up Geotechnics Concrete Pipe and Culvert Clay DrainageManhole Solutions

Centre Hinged Double Triangular

Download a copy of our Civils and Drainage Guide at www.keyline.co.uk

266 Utilities | Covers and Frames Utilities | Covers and Frames 267The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.

Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.

Double TriangularDouble Triangular

Ductile Iron Covers and Frames – D400

BS EN 124 Loading Class

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Cover Mass (kg)

Total Mass (kg)

D400N 600 x 600 803 x 803 150 45* 84

D400N 600 x 600 820 x 770 150 45* 92

D400N 600 dia 820 x 770 150 50* 97

D400N 675 x 675 880 x 830 150 70* 124

D400N 675 x 675 880 x 830 150 69* 122

D400N 750 x 600 960 x 810 150 70* 120

Recommended for use in city roads carrying heavy traffic. Recommended for use in city roads carrying heavy traffic.

Features:

Double triangular

Non-rock design

LTS Installation and durability features

HA 104/2 compliant

Sewers for Adoption 6 compliant.

Options:

Security locking option

Ventilated option

Safety grid option on certain units.

Features:

Double triangular

Non-rock design

HA 104/2 compliant

Sewers for Adoption 6 compliant.

Options:

Badging options

Security locking option.

BS EN 124 Loading Class

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Cover Mass (kg)

Total Mass (kg)

D400N 450 x 450 600 x 600 100 32* 53

D400N 600 x 450 800 x 650 100 41* 71

D400N 600 x 600 800 x 800 100 45* 74

D400N 600 x 600 800 x 800 100 49* 82

D400N 600 dia 800 x 800 100 50* 87

D400N 600 dia 800 x 800 100 49* 86

D400N 675 x 675 850 x 830 100 70* 107

D400N 675 x 675 850 x 830 100 69* 106

D400N 675 dia 830 x 830 100 70* 108

D400N 675 dia 830 x 830 100 69* 107

D400N 750 x 600 950 x 800 100 70* 106

D400N 750 x 750 1005 x 1005 100 48 151

D400N 750 x 750 1005 x 1005 100 47 150

D400N 900 x 600 1100 x 800 100 44 131

D400N 900 x 600 1100 x 800 100 43 129

D400N 900 x 900 1163 x 1155 125 74 223

D400N 1250 x 675 1500 x 875 100 70* 201

D400N 1250 x 675 1500 x 875 100 69* 199

150mm deep units

100mm deep units

Ductile Iron Covers and Frames – D400

BS EN 124 Loading Class

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Cover Mass (kg)

Total Mass (kg)

Open Keyways

D400N 1210 x 685 1375 x 850 100 69* 208

D400N 1825 x 685 1985 x 850 100 69* 307

D400N 1210 x 685 1375 x 850 150 69* 241

D400N 1825 x 685 1985 x 850 150 69* 354

Closed Keyways

D400N 1210 x 685 1375 x 850 100 73* 215

D400N 1825 x 685 1985 x 850 100 73* 318

D400N 1210 x 685 1375 x 850 150 73* 248

D400N 1825 x 685 1985 x 850 150 73* 365

Suited for use in pedestrian areas, walkways, footpaths, platforms and stations.

Ergonomic cover operation Locking options availableBadging options available.

Valiant

BS EN124 Class Clear Opening (mm) Overbase (mm) Frame Depth (mm) Total Mass (kg)

B125 600 x 450 750 x 605 75 53

B125 600 x 600 750 x 750 75 63

B125 900 x 600 1070 x 770 75 89

* Cover mass per pair.

Ductile Iron Covers and Frames – B125Slide Out Single Seal Access Cover

268 Utilities | Covers and Frames Utilities | Covers and Frames 269The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.

Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.

Slide Out Access Cover Hinged Gully Grates

GripTop is a permanent high friction solution for access cover installations that due to their location pose a slip or skid risk to pedestrians or vehicles.

Recommended for use in city roads carrying continuous heavy traffic, with the addition of captive hinge for ease of maintenance.

Ductile Iron Covers and Frames – B125 Gully Grates – D400

Available in a large range of clear opening sizes, Rapide offers ease and speed of use while promoting operator safety through a cover slide out feature reducing the risk of injury while lifting even for light duty applications.

Ergonomic cover operation

Locking options available

Badging options available.

Rapide

BS EN 124 ClassClear Opening

(mm) Overbase (mm) Frame Depth (mm) Total Mass (kg)

B125 380 x 230 480 x 330 40 14

B125 550 x 325 650 x 425 40 25

B125 450 x 450 550 x 550 40 24

B125 600 x 450 700 x 550 40 31

B125 600 x 600 700 x 700 40 39

B125 750 x 600 850 x 700 40 49

B125 900 x 600 1000 x 700 50 69

B125 1000 x 675 1100 x 775 50 80

B125 1310 x 610 1410 x 710 50 90

Features a patented factory applied high friction treatment which combines high performance bonding agents with a bauxite aggregate applied to a recessed ductile iron cover section.

Proven in service durability

Demonstrates an industry leading PSRV of > 75.

Features:

Captive hinged grating

Non-rock design

Single-piece grating.

Options:

Security locking option.

GripTop

BS EN 124 ClassClear Opening

(mm) Overbase (mm) Frame Depth (mm) Total Mass (kg)

E600 610 x 610 815 x 815 150 126

D400 600 x 600 800 x 800 100 74

D400 600 x 600 800 x 800 150 83

D400 675 x 675 880 x 830 100 94

D400 675 x 675 880 x 830 150 104

D400 600 x 600 806 x 806 100 96

D400 600 x 600 806 x 806 150 119

D400 675 x 675 880 x 830 100 109

D400 675 x 675 880 x 830 150 130

D400 600 x 600 800 x 800 100 95

D400 600 x 600 800 x 800 150 106

D400 675 x 675 875 x 875 100 120

D400 675 x 575 875 x 875 150 142

D400 900 x 600 1100 x 800 100 135

D400 900 x 600 1100 x 800 150 144

D400 1220 x 685 1380 x 885 100 214

D400 1220 x 685 1380 x 885 150 249

D400 1830 x 685 2000 x 885 150 354

Suited for use in pedestrian areas, walkways, footpaths, platforms and stations.

Features:

Captive hinged grating

Non-rock design

Single-piece grating.

For use in heavy and mediumduty applications.

DescriptionBS EN 124

Loading ClassClear Opening

A x B (mm)Over Base C x D (mm)

Depth E (mm)

Waterway Area (cm2)

HA102 Reference

Total Mass (kg)

Left Hand Opening D400 360 x 310 510 x 410 100 765 S 29

Left Hand Opening D400 400 x 430 550 x 520 100 1223 Q 38

Left Hand Opening D400 500 x 350 645 x 440 100 1080 R 46

DescriptionBS EN 124

Loading ClassClear Opening

A x B (mm)Over Base C x D (mm)

Depth E (mm)

Waterway Area (cm2)

HA102 Reference

Total Mass (kg)

Kerb Hinging D400 370 x 430 575 x 630 100 980 R 48

Kerb Hinging D400 370 x 430 525 x 590 100 980 R 41

Left Hand Opening D400 370 x 430 575 x 525 100 1020 R 41

Right Hand Opening D400 370 x 430 575 x 525 100 1020 R 41

GripTop – D400High Friction Anti-Skid and Anti-Slip Access Cover Range

270 Utilities | Covers and Frames Utilities | Covers and Frames 271The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.

Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.

Gully Grates – D400 Surface Boxes

Features:

Double triangular grating

Non-rock design

Large waterway area

LTS installation and durability features.

Options:

Three or four flanged frame option.

Large waterway area provides efficient water removal in areas subject to high water run-off eg. catchpits, motorway verges, between verges and valleys, cuttings etc.

DescriptionBS EN 124

Loading ClassClear Opening

A x B (mm)Over Base C x D (mm)

Depth E (mm)

Waterway Area (cm2)

HA102 Reference

Grating Mass (kg)

Total Mass (kg)

Double Triangular D400 600 x 600 800 x 800 100 2000 57* 89

Double Triangular D400 600 x 600 720 x 800 100 2000 P 57* 86

Double Triangular D400 600 dia 800 x 800 100 2000 57* 92

Double Triangular D400 600 x 600 820 x 770 150 2000 57* 99

* Grating mass per pair.

Grade A Double Triangular Surface Box

Recommended for use in city and roads carrying heavy traffic.

Features:

Non-rock design

Single-piece cover

Badging options

Security chain option.

BS5834 Grade

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Total Mass (kg)

A 150 x 150 225 x 225 100 8.5

A 150 x 150 260 x 245 225 14

A 225 x 225 325 x 325 100 14

A 300 x 300 400 x 400 100 20

A 380 x 230 505 x 355 125 26

A 380 x 230 505 x 355 125 26

Traditional double triangular design for use in city roads carrying heavy traffic.

Recommended for use in city and trunk roads carrying heavy traffic.

Features:

Double triangular

Non-rock design

Badging options

Security chain option.

Features:

Wider flange to prevent lateral movement

Non-rock design

Single-piece cover

Badging options

Security chain option.

BS5834 Grade

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Total Mass (kg)

A 430 x 280 550 x 400 100 38

BS5834 Grade

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Total Mass (kg)

A 380 x 230 535 x 385 125 27

Double Triangular Gully Grate Grade A Surface Box – Wide Flange

Surface BoxesGrade A Surface Box

272 Utilities | Covers and Frames Utilities | Covers and Frames 273The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.

Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.

Surface Boxes Steel Covers and Frames

Features:

Single-piece cover

Hinged

Badging options.

Recommended for use in pavements and other pedestrian areas where hinged access is required.

BS5834 Grade

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Spigot I/D F (mm)

Total Mass (kg)

Medium 135 x 125 215 dia 75 4.2

Medium 180 dia 275 x 275 60 7.6

Medium 180 dia 240 x 240 110 202 8.5

Medium 180 dia 240 x 240 110 202 8.5

Grade A Hinged Pavement Surface Box

Suggested suitable carrying capacities for standard steel covers and frames*

Recommended for use in areas subject to heavy loading but not subject to fast-moving through traffic.

Features:

Solid top cover.

BS5834 Grade

Clear Opening A x B (mm)

Over Base C x D (mm)

Depth E (mm)

Total Mass (kg)

A 100 x 100 190 x 190 100 6

Grade A Solid Top Surface Box Engineered Steel Products

Ref. A Gross Plated Weight 2.5T. For pedestrian use only.

Ref. B Gross Plated Weight 5T. Will support a slow moving wheel load of 1.25T. Especially recommended for domestic driveway applications.

Ref. C Gross Plated Weight 10T. Will support a slow moving wheel load of 2.5T. Restricted access and service areas.

Ref. D Gross Plated Weight 17T. Will support a slow moving wheel load of 4.25T. Small rigid commercial vehicles.

Ref. EGross Plated Weight 25T.Will support a slow moving wheel load of 6.25T. Pedestrian precincts, commercial delivery access and emergency services.

Ref. FGross Plated Weight 38T.Will support a slow moving wheel load of 9.5T. Petrol forecourt and articulated lorries.

Other TrafficKeyline must be notified if inspection covers ordered are to carry vehicles with non pneumatic tyres eg. forklifts, mobile cranes, short wheel trollies etc. plus aircraft or any abnormal traffic.

Fabricated steel covers provide a highly versatile solution to a large range of access requirements. Keyline is able to supply an extensive range to fulfil even the most demanding specifications.

Whatever the application, Keyline can provide the solution you need.

Recessed block pavior covers

Recessed covers for screed infill

Stainless steel edge or brass edge covers

Hinged – spring assisted

Manual handling compliant

Protection from falling

MOD approved

Security covers

Ducting runs

Complete stainless steel or aluminium covers

Kitemarked precinct range.

All bespoke items are manufactured in accordance to FACTA (Fabricated Access Covers Trading Association) specifications.

2 Part Flush Cover 3 Part Flush Cover

4 Part Recessed

274 Utilities | Covers and Frames Utilities | Covers and Frames 275The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.

Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.

Steel Covers and Frames Steel Covers and FramesAccess CoversHinged Access Covers

Upstanding

Single skin and water shedding

Internal fixings for increased security

Shrouded hasp and staple for use with Utility padlocks

Supplied as standard with single hinged safety grids

Torsion spring assisted for one person operation

Covers incorporate safety stays to prevent accidental closure

Galvanised to BSEN ISO1461

Anti-Slip and powder coatings are available.

Size Range Available in a multitude of sizes from 300 x 300mm, to suit any chamber opening dimensions.

Cover configuration include Single Twin – In line hinged Twin – End hinged Triple – In line hinged Triple – End and mid hinged Multiple configurations.

Precinct

Designed in accordance with BT spec LN593

Kitemarked in accordance to BSEN124 class B125

Manufactured from 6mm material.

Depth to suit 65mm blocks

Solid base flange to ensure stability under load

Slide out design for easy removal

Hot dip galvanized to BS EN ISO 1461

Available in a range of sizes to suit chamber references 2,4,5,6,10,11 & JC1

Non kitemarked ranges of paviour units are also available.

Stamplock

Flush fitting access cover

Internal fixings for increased security

Recessed Stamp-Lock locking for use with Utility padlocks

Supplied as standard with single hinged safety grids

Torsion spring assisted for one person operation

Covers incorporate safety stays to prevent accidental closure

Galvanised to BSEN ISO1461

Anti-Slip and powder coatings are available.

Size Range Available in a multitude of sizes from 300 x 300mm, to suit any chamber opening dimensions.

Cover configuration include Single Twin – In line hinged Twin – End hinged Triple – In line hinged Triple – End and mid hinged Multiple configurations.

Biomass

Multiple gas ram and spring assisted single person operation

Galvanised to BSEN ISO1461.

Upstanding access covers and frames are designed for use on a variety of projects containing chambers that are opening frequently and are not subject to vehicular traffic. The upstanding range incorporates torsion spring assistance for ease of opening by one person and are frequently used over wet wells, valve and screen chambers, but are not limited to this application. This range is particularly useful on refurbishment sites that require an economical solution that will be easily installed within existing conditions.

Mild steel high quality access covers are available to suit a multitude of applications and infill materials. These ranges are fabricated to the highest standards to ensure continued performance under operation and load.

The Keyline range of flush fitting access covers and frames include the unique Stamp-Lock locking device as standard. The Stamp-Lock devices allow for the padlock to be contained within the locking device and is extremely easy to open and close. The range has been designed for use for use on a variety of projects containing chambers that are opened frequently and are subject to slow moving vehicular traffic. The range incorporates torsion spring assistance for ease of opening by one person. Stamp-Lock products, are frequently used over wet wells, valve and screen chambers, but are not limited to these applications. They also include sealed and unsealed variations, with differing frame depths for ease of installation.

Keyline provide access solutions for high profile schemes that use heating systems, which are powered by Biomass fuel. To continue to provide up to date cost effective solutions for varying applications, Steelway now have available a light duty gas assisted hinged access cover for storage facilities that are not subject to vehicular access. The new product compliments the existing range of large opening modular cladded buildings and extremely popular flush fitting hydraulic fuel storage covers.

276 Utilities | Covers and Frames Utilities | Covers and Frames 277The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.

Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.

Steel Covers and Frames Steel Covers and FramesGalvanised Steel Solid Top Access Covers

Clear Opening (mm)

Overall Size (mm)

5T GPW 300 x 300 363 x 363

450 x 450 513 x 513

600 x 450 663 x 513

600 x 600 663 x 663

17T GPW 600 x 450 663 x 513

600 x 600 663 x 663

Please contact Keyline for advice should you require units slightly over the specifications shown. Gross vehicle plated weight expressed as the gross weight of road vehicles with pneumatic tyres and four points of road contact.

Loads to FACTA classes can be supplied on request.

Chequer Plate Covers

Clear Opening (mm)

Overall Size (mm)

Overall Depth (mm)

5T GPW 600 x 450 656 x 506 50

600 x 600 656 x 656 50

750 x 600 824 x 674 50

900 x 600 974 x 674 50

38T GPW 450 x 450 510 x 510 50

600 x 450 660 x 510 50

600 x 600 660 x 660 50

600 x 510 656 x 506 50

High Security Access Covers

Sentry

Moated twin skin high security access cover and frame

Specific products and configurations are LPS1175 SR4 certified

Internal fixings for increased security

Supplied as standard with single hinged safety grids

Torsion spring assisted for one person operation

Covers incorporate safety stays to prevent accidental closure

Galvanised to BSEN ISO1461.

Size Range Available in a multitude of sizes from 300 x 300mm, to suit any chamber opening dimensions.

Covers configurations include Single Twin – In line hinged Twin – End hinged Multitude configurations and bespoke layouts with lift off units.

Finishes include Galvanised mild steel Self colour stainless steel Powder coated to all available RAL colours Non slip coating.

Loadings Pedestrian duty for use in areas not subjected to vehicular traffic.

Our range of Sentry High Security access covers and frames include products designed and fabricated in line with LPS1175 SR4 specification. The range has been designed for use on a variety of projects including clean water reservoir chambers. The range incorporates torsion spring assistance for ease of opening by one person. On projects which require non standard sizes and products which sit outside of the scope of the specification, we have the flexibility to design and fabricate in line with the same requirements but note that they will not be certified.

278 Utilities | Covers and Frames Utilities | Covers and Frames 279The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.

Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.

See our Geotechnics Guide for more information

Steel Covers and Frames Steel Covers and FramesSquare-to-Round Recessed Cover

Clear Opening (mm)

Depth (mm)

Overall Size (mm)

Loading GPW

300 80 438 x 438 x 93 Driveway

450 80 580 x 580 x 88 Driveway

450 43.5 580 x 580 x 54 Driveway

Square-to-Round Recessed Cover

Quick and easy to install

Cover can be turned to match direction of paving

Circular opening in frame fits all major PPIC inspection chambers

Eliminates the need to cut paving round a circular opening

Guaranteed interchangeability

Galvanised to BS EN 1461.

CLKS 450SR

Block

Frame

Standard 450mm dia PPIC

chamber

Cover

Recessed Access Covers

Internal Recessed Type Sealed and Locking

Clear Opening (mm)

Overall Size (mm)

5 Tonne GPW 300 dia 440 x 440

450 dia 580 x 580

600 x 450 740 x 590

600 x 450 740 x 590

600 x 600 740 x 590

750 x 600 850 x 700

750 x 750 850 x 850

900 x 600 1000 x 700

Recessed Access Covers

Paviour Type

Clear Opening (mm)

Overall Size (mm)

10 Tonne GPW 300 dia 438 x 438

450 dia 580 x 580

600 x 450 695 x 545

600 x 450 695 x 545

600 x 450 700 x 650

600 x 600 690 x 690

600 x 600 700 x 700

750 x 600 850 x 700

750 x 750 850 x 850

900 x 600 1000 x 700

900 x 900 1000 x 1000

1200 x 600 1300 x 700

38 Tonne GPW 600 x 600 800 x 800

750 x 600 950 x 800

750 x 750 950 x 950

900 x 900 1100 x 1100

1200 x 600 1400 x 800

Recessed Access Covers

Internal Recessed Type Sealed and Locking (treated to 1 metre head of pressure)

Clear Opening (mm)

Overall Size (mm)

5 Tonne GPW 450 x 450 550 x 550

600 x 450 700 x 550

600 x 600 700 x 700

750 x 600 850 x 700

750 x 750 850 x 850

900 x 600 1000 x 700

280 Utilities | Covers and Frames The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.

Visit www.keyline.co.uk to find out more information on specialist utilities

products now in stock.

Utilities Stock Range