18
Machine erManu I '. , f I t , / I I e I / ., . . ' . \. . \ -- -- - . �.,.' I I , , . . , . ' I I I f ' f J ; f I • t ' l - ' ;, . . . ' . . . . \ '. 1/ '. , ·- . \ '• ' www.bodylifedot.com

DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

Machine

erManu

• I '. ,

f I

t •, / • • •

I I

• e I/

.,

• • . . ' . \.

. \ ------· . �.,. '

I • I , •

, . . , . ' I I I f ' f • J • • • • •

; f I • t • • • • • ' l -' ;, . . . ' . .. . . . \ '.1/ • • • • • '. •

, ·- . \ '• ' ••

• •

www.bodylifedot.com

Page 2: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

Product Display

Page 3: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

1

1.1. Product Appearance And Part Description1.2. Packing List1.3. Treatment Principle1.4. Application1.5. Specifications

4.1. Turn On The Equipment4.2. Initialization Interface4.3. Handpiece Selection Interface4.3.1. SHR Mode4.3.2. OPT Mode4.4. Settings Interface

2.1. Clients Safety2.2. Optics Safety2.3. Electrical Safety2.4. Fire Prevention2.5. Safety Device

3.1. Install Handpiece Stand3.2. Fill Water And Change Water

5.1. Preventive Maintenance5.2. Moving The Machine5.3. Transport The Machine

6.1. Parameter Settings

Contents

Machine IntroductionChapter 1

Using NoticeChapter 2

Machine InstallationChapter 3

Product Operations GuideChapter 4

Maintenance And TroubleshootingChapter 5

Clinical GuideChapter 6

WarrantyChapter 7

About UsChapter 8

Page 4: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

www.bodylifedot.com

2

Chapter 1. Machine Introduction

1.1. Product Appearance And Part Description

Touch screen,Easy to operate

Key

SHR IPL Handle

Emergency Button

Imported Plug Connector

Air Fans

Add Water Hole

Fuse

Air Switch

Power Line

Water Level Window

Output Water Hole

Overflow Hole

Pedal

Page 5: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

1.2. Packing List

1.3. Treatment Principle

3

OPT SHR IPL can emit high engery light, which can reach the derma layer , it can be absorbed selectively by the tissue pigmentation and hemoglobin of vascular, it can make the pigmentation and the expansion capillaries break and explode. Also, this light canbreak the hair follicle, and stop the hair grow , also, it can stimulate the collagen regrow and make the skin rejuvenation . In a word , ipl machine has the functions of vascular removal , pigmentation removal , hair removal and skin rejuvenation.

1.4. Application

Headpiece x 2

Machine Host x 1

Power Line x 1

Operator Glasses x 1 Customer Goggle x 1

Bracket x 2

Key x 2

Water Nozzles x 3

Foot Switch x 1Fuse x 1

Skin Rejuvenation

Pigmentation Removal

Vascular Removal Acne removal

Hair Removal

Page 6: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

2.2. Optics Safety

4

1.5. Specification

1-50J/cm²Energy Density (Fluence) :

Spot Size :

Pulse Repetition Rate :

15x50mm² ( SHR);12x30mm² (OPT);10×50mm(SR optional)

Wavelength (Spectrum): 640nm-950nmSHR;560nm-950nmOPT

1-10Hz

Continuous Crystal contact cooling (-4°C-2°C ) + Air cooling + Closed water circulation cooling

Cooling:

Stand-by Working: Continuously for 18 hours

Out Put Power 3000W

10.4" True Color LCD Touch Screen

100-240VAC, 20A max., 50/60Hz

Display:

Electrical Requirements:

60 kgsNet Weight :

63*53*126cmDimensions (WxDxH) :

Chapter 2. Using Notice

2.1. Clients Safety 1). Pregnant women;2). Heart disease;3). Suffer high blood pressure.4). Have photosensitive skin or cicatricial diathesis;5). Have taken any photosensitive medicine recently;6). Received any IPL peeling treatments within half a year7). Received any chemical peeling treatments within half a year.

1). Do not wear jewelry, watches or spectacles reflecting intense pulsed light;2). Intense light can do harm to eyes and cause fire. During clinical treatment, beautician and customer shall wear goggle;3). The operating handpiece can not be used outside the scope of this manual;

Page 7: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

5

4). Skin might get hurt if it absorbs too much light energy;5). Put the handpiece on the handpiece stand if you don’t use it;6). Keep the handpiece crystal clean and do not make cooling gel leak into handpiece;7). Use cooling gel to protect the skin while treating.

2.4. Fire Prevention

1). The clinic room shall not be easy to get fire;2). If you cleaned the equipment with alcohol, you shall not turn on the equipment until it is totally dry;3). If you don’t use this equipment for a long time, cut off the power supply.

2.3. Electrical Safety

2.5. Safety Device

Air Switch: If the electricity is abnormal, this electricity breaker would automatically cut off electricity;Emergency Button: Press it and power is cut off. Turn it clockwise to connect power;

Key switch: It is used to turn on and turn off power;

1). The power supply shall be AC230V±10%,50Hz±1Hz/AC110V±10%,60Hz±1Hz;2). Before maintenance, turn off equipment and wait for 10 minutes;3). No one is allowed to disassemble any parts of the equipment except the technical personnel appointed by our company;4). If you find the handpiece leaking water, don’t turn on the equipment. If it has been turned on, please turn it off;5). The power line of the this equipment could conduct unexpected electricity to earth;6). People in the clinical room shall know how to turn off the equipment.

Emergency SwitchAir Switch Key switch

Page 8: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

6

Chapter 4. Product Operations Guide

Chapter 3. Machine InstallationAfter purchasing this equipment, make installation and initial system testing.

3.1. Install Handpiece Stand

1). Install handles2). Connect power line,foot pedal

3.2. Fill Water And Change Water1). Insert water nozzles to overflow water hole and add water hole2). Use pipe and Funnel to add water in machine tank3). Pay attention to water level window and when water flow out, it’s ok

4.1. Turn On The Equipment

4.2. Initialization Interface

Connect the power line,make the air switch up,press the emergency button.First time using machine,turn on machine and turn off three times,the third time turn on it and keep 30s.

Power switch on,into “Welcome” interface.(Figure 1)

(Figure 1)

Page 9: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

77

Touch screen will be in ( Figure 2 )

Choose Language press enter into next interface ( figure 3 )

Treatment model description:SHR for hair removal ,OPT for different 5 kinds functions. Choose SHR enter into ( Figure 4 )

4.3. Handpiece Selection Interface

(Figure 2)

(Figure 3)

Page 10: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

88

SHR hair removal operation screen. (Figure 4)

Choose Male or Female,Skin Type. Hair Density , Hair Color and Hair Thickness. then Enter into Next Main Operate Interface. (Figure 5)

SHR power control range 1—50J/CM²,adjust according customer's physical condition ,can adjust under treatment.

Screen description:

(Figure 4)

(Figure 5)

4.3.1. SHR Mode

Page 11: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

9

Handle refrigeration adjust range:1—5,adjusting when you need under treatment.(PS:when you do treatment,you must set the refrigeration range)

Time setting range is 1-10S, this time after the release of the pedal is not pressed emission time, the cure process can be adjusted.

First column is this cure times above the display,followed by zero point reset key. The second shows the total number of therapeutic

cure mode To this end, in the background settings interface can be cleared (at the back will detail how to be cleared).

After all the settings are finished, ready to start charging thepre-combustion work, then the interface will become standby ,

after 1second becomes a successful pre-combustion and then you can start to treatment.

(This picture shows the ready status icon display.)

PS: Descripition of Different icons.

1.handle: the inactive state, the active state.

2. normal temperature.

3. normal water flow.

4. the charged state,can work as usual. the uncharged statethe.

5. work status

6. back to (Figure 4)

Page 12: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

OPT Operate guide is same with SHR Operate

4.3.2. OPT Mode

10

If you press OPT treatment mode. it will enter into five interface as followed picture;

Choose for different functions Operate guide is same with SHR Operate.

If you would like to set Frequency or other parameters.

Please press this button enter into followed screen.

4.4. Settings Interface

(Figure 6)

(Figure 7)

Page 13: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

11

Press that then into ( Figure 8 )

1. is (Figure 6)

2. is (Figure 9)

3. press “+” or “-” to adjust ms.

4. shots count

5. set water temperature alarm number

(Figure 8)

(Figure 9)

Page 14: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

12

6. water temperature alarm

7. water flow alarm

8. back to main interface

Chapter 5. Maintenance And TroubleshootingIn order to provide you with the best possible service we ask that you carefully Review these Pre- and Post-Treatment instructions for the SHR IPL treatments for laser hair removal and ask any questions necessary to help you fully understand them. If you have any questions about these instructions, please discuss them with us prior to treatment.To obtain maximum benefit from your treatments, it is crucial that you understand and adhere to these instructions. Failure to comply with these instructions may affect your treatment outcome and increase the likelihood or severity of complications.We are confident that if you follow these instructions, you will be pleased with the results of your treatments.

1). Preventive maintenance carried out by our authorized technical personnel. 2). When submitting a service request, please provide the serial number on the instrument or photos.3). To contact with our authorized representative.

5.1. Preventive Maintenance

Move the machine, unlock four Footswitch switch, promote the instrument movement. Before moving the unit, remove the Footswitch switch and power cord. It is forbidden to drag the handpiece and the power cord.

5.2. Moving The Machine

Page 15: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

Preparation:(1). Unplug the power socket(2). Unplug the power cord(3). Unplug the Footswitch switch(4). Contact our company about transport matter

Attention! Transportation equipment must use the original packaging materials. otherwise it will damage the warranty terms.

5.3. Transport The Machine

13

6.1. Parameter Settings

This OPT Hair Removal Treatment Parameters based on the different type skin customer feedback, which use the OPT Beauty Equipment do a hair removal or skin care treatment.This Parameter used for the most people, but everyone body will have some different,the salon treatment operator can do some adjustments combine the each client detail situation.

Chapter 6. Clinical Guide

Skin Type I

Part Times Refrigerat Frequeny Pulse Energy

Underarm 4~8s 5 1~2Hz 3.1~4.7Ms 15~18J

Face 7~10s 5 2~4Hz 4.6~5.2Ms 16~20J

Back 9~12s 5 4~6Hz 5.0~5.8Ms 19~22J

Arm 10~14s 5 6~8Hz 5.4~6.1Ms 21~24J

Leg 13~16s 5 8~10Hz 5.9~5.8Ms 23~26J

Page 16: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

14

Skin Type III

Part Times Refrigerat Frequeny Pulse Energy

Underarm 4~8s 5 1~2Hz 3.1~3.6Ms 11~14J

Face 7~10s 5 2~4Hz 3.4~4.0Ms 16J

Back 9~12s 5 4~6Hz 3.9~4.5Ms 18J

Arm 10~14s 5 6~8Hz 4.3~4.9Ms 20J

Leg 13~16s 5 8~10Hz 4.5~5.1Ms 22J

Skin Type II

Part Times Refrigerat Frequeny Pulse Energy

Underarm 4~8s 5 1~2Hz 3.2~3.8Ms 13~16J

Face 7~10s 5 2~4Hz 3.6~4.2Ms 15~18J

Back 9~12s 5 4~6Hz 4.0~4.7Ms 17~20J

Arm 10~14s 5 6~8Hz 4.3~5.1Ms 19~22J

Leg 13~16s 5 8~10Hz 5.1~5.6Ms 21~24J

Page 17: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

15

Skin Type VI

Part Times Refrigerat Frequeny Pulse Energy

Underarm 4~8s 5 1~2Hz 1.8~2.3Ms 7~10J

Face 7~10s 5 2~4Hz 2.1~2.6Ms 9~12J

Back 9~12s 5 4~6Hz 2.5~3.1Ms 11~14J

Arm 10~14s 5 6~8Hz 2.9~3.6Ms 13~16J

Leg 13~16s 5 8~10Hz 3.4~3.9Ms 15~18J

Skin Type IV

Part Times Refrigerat Frequeny Pulse Energy

Underarm 4~8s 5 1~2Hz 2.3~2.9Ms 10~12J

Face 7~10s 5 2~4Hz 2.7~3.2Ms 14J

Back 9~12s 5 4~6Hz 3.0~3.6Ms 16J

Arm 10~14s 5 6~8Hz 3.4~3.9Ms 18J

Leg 13~16s 5 8~10Hz 3.7~4.3Ms 20J

Page 18: DORA手册bodylife-lb.com/wp-content/uploads/2019/03/User-Manual... · OPT Operate guide is same with SHR Operate 4.3.2. ... Maintenance And Troubleshooting ... Back 9~12s 5 4~6Hz

16

1.All products are strictly tested before sale. We can guarantee one-year free repair fromthe date of purchasing.During the guarantee period, we will repair the machine by free if the malfunction iscaused by the quality of our product.

2.The standard of operation and environment should comply with the product specification.

3. Malfunctions caused by the following reasons are out of the scope of our guarantee:a. Malfunctions caused by abused operation;b. Malfunctions caused by other artificial factors like move or tear down in proper motion,

or collision, etc;c. Energy reduce caused by wet environment and dust;d. Malfunction caused by uncontrollable natural force;e. Spare parts and accessories of this machine.

Chapter 7. Warranty

Our Engineers

READY TO SERVE YOU!

www.bodylifedot.com