1
20 DOMEKT Domekt R 250 F (Domekt REGO 250P) B D A C B D A C E D A C B D C A B 61 68 61 68 42 31 250 25 41 1~ 230 HE 6,3 / HW 2,3 82 0,05 50 0,48 278×258×46-M5 36 96 1,0 / 16,5 KOMFOVENT C4 / C4.1 0,8 0,8 0,8 0,8 36 36 36 36 1 1 1 1 12/22 2,2 1,8 1,3 0,9 ½ 315x315x220 DH-160 C4 C4.1 B 250 m³/h 42 0 0,02 0,04 0,06 0,08 0 50 100 150 200 250 300 250 200 150 100 50 0 SFP 0,75 SFP 0,5 SFP 1 SFP 1,25 50 100 150 200 250 300 92 88 84 80 76 72 12 13,8 14,9 16 17,1 23,8 20 205 125 280 20 155 155 790 310 310 830 125 175 125 175 550 160 (4×) KK2-16-03 UAB AMALVA reserves the right to introduce the changes of parameters and sizes in the process of improvement of the air handling units. All data can be calculated in DOMEKT selection software. If data of performance do not correspond to data in the selection software, please refer to data shown in software. The photo is intended for informational purposes only, exact details may vary. Static pressure (Pa) Performance Air flow rate (m 3 /s) Air flow rate (m 3 /h) Air flow rate (m 3 /h) Temp. efficiency (%) Temperature efficiency Indoor and outdoor ∆T=13°C re: Ecodesign 1254/2014. Acoustic Data A-weighted sound power level L WA , dB(A) at reference flow rate Supply Inlet Supply Outlet Exhaust Inlet Exhaust Outlet Casing A-weighted sound pressure level L PA , dB(A) 10 m² normally isolated room, distance from casing – 3 m. Surroundings Nominal air flow, m³/h Panel thickness, mm Unit weight, kg Supply voltage, V Maximal operating current, A Thermal efficiency of heat recovery, % Reference flow rate, m³/s Reference pressure difference, Pa SPI, W/(m³/h) Filters dimensions B×H×L, mm Electric power input of the fan drive at reference flow rate, W Electric power input of the fan drive at maximum flow rate, W Electric air heater capacity, kW / ∆t, °C Control panel Hot water duct air heater (DH)** Winter Water temperature in/out, °C 90/70 80/60 70/50 60/40 Capacity, kW Flow rate, dm³/h Pressure drop, kPa Temperature in/out, °C Maximal capacity, kW Connection, ” Dimensions, mm Hot water duct heater type ** option Temperature efficiency Winter Summer Outside temperature, °C -23 -15 -10 -5 0 30 After heat exchanger*, °C * indoor +22°C, 20 % RH A outdoor intake B supply air C extract indoor D exhaust air E additional extraction connection (by-pass – extraction without heat recovery) Shown as right (R2) Shown as left (L2)

Domekt R 250 Fprokliima.ee/wp-content/uploads/2017/05/DOMEKT_R_250_F.pdf20 DOMEKT Domekt R 250 F (Domekt REGO 250P) B D A C B D A C E D A C B C D B 61 68 61 68 42 31 250 25 41 1~ 230

Embed Size (px)

Citation preview

Page 1: Domekt R 250 Fprokliima.ee/wp-content/uploads/2017/05/DOMEKT_R_250_F.pdf20 DOMEKT Domekt R 250 F (Domekt REGO 250P) B D A C B D A C E D A C B C D B 61 68 61 68 42 31 250 25 41 1~ 230

20

DOMEKT

Domekt R 250 F (DomektREGO250P)

B

D

A

C

B

D

A

C

E

D

A

C

B

DC

AB

61

68

61

68

42

31

250

25

41

1~ 230

HE 6,3 / HW 2,3

82

0,05

50

0,48

278×258×46-M5

36

96

1,0 / 16,5

KOMFOVENT C4 / C4.1

0,8 0,8 0,8 0,8

36 36 36 36

1 1 1 1

12/22

2,2 1,8 1,3 0,9

½

315x315x220

DH-160

C4

C4.1

B

250 m³/h42

0 0,02 0,04 0,06 0,08

0 50 100 150 200 250 300

250

200

150

100

50

0

SFP 0,75

SFP 0,5

SFP 1

SFP 1,25

50 100 150 200 250 300

92

88

84

80

76

72

12 13,8 14,9 16 17,1 23,820 205125

280

20

155 155790

310 310830

125

175

125

175

550

160 (4×)

KK2-16-03UAB AMALVA reserves the right to introduce the changes of parameters and sizes in the process of improvement of the air handling units.All data can be calculated in DOMEKT selection software. If data of performance do not correspond to data in the selection software, please refer to data shown in software.

The

phot

o is

inte

nded

for i

nfor

mat

iona

l pur

pose

s on

ly, e

xact

det

ails

may

var

y.

Stat

ic p

ress

ure

(Pa)

Performance Air flow rate (m3/s)

Air flow rate (m3/h)

Air flow rate (m3/h)

Tem

p. e

ffici

ency

(%)

Temperature efficiency

Indoor and outdoor ∆T=13°C re: Ecodesign 1254/2014.

Acoustic DataA-weighted sound power level LwA, dB(A)at reference flow rate

Supply Inlet

Supply Outlet

Exhaust Inlet

Exhaust Outlet

Casing

A-weighted sound pressure level LPA, dB(A) 10 m² normally isolated room, distance from casing – 3 m.

Surroundings

Nominal air flow, m³/h

Panel thickness, mm

Unit weight, kg

Supply voltage, V

Maximal operating current, A

Thermal efficiency of heat recovery, %

Reference flow rate, m³/s

Reference pressure difference, Pa

SPI, W/(m³/h)

Filters dimensions B×H×L, mm

Electric power input of the fan drive at reference flow rate, W

Electric power input of the fan drive at maximum flow rate, W

Electric air heater capacity, kW / ∆t, °C

Control panel

Hot water duct air heater (DH)**winter

Water temperature in/out, °C 90/70 80/60 70/50 60/40

Capacity, kW

Flow rate, dm³/h

Pressure drop, kPa

Temperature in/out, °C

Maximal capacity, kW

Connection, ”

Dimensions, mm

Hot water duct heater type

** option

Temperature efficiencywinter Summer

Outside temperature, °C -23 -15 -10 -5 0 30

After heat exchanger*, °C

* indoor +22°C, 20 % RH

A outdoor intakeB supply airC extract indoorD exhaust airE additional extraction connection (by-pass –

extraction without heat recovery)

Shown as right (R2)

Shown as left (L2)