San Pablo Park Restroom Renovation Specification No. 18-11210-C Addenda 00 9113-1 DOCUMENT 00 9113 ADDENDA SPECIFICATION NO. 18-11210-C CITY OF BERKELEY SAN PABLO PARK RESTROOM RENOVATION 2800 PARK ST., BERKELEY, CA 94702 The following Addenda were issued, modifying the Project Manual: Addendum No. 1, issued on August 28, 2018 (Addenda have been incorporated into the conformed Project Manual.) END OF DOCUMENT

DOCUMENT 00 9113 ADDENDA SPECIFICATION …...JET TOILET - FLOOR OUTLET - ADA COMPLIANT ACORN ENGINEERING COMPANY PENAL -WARE 1695-W-3-HET-FVL-ADA FV WALL SUPPLY 1.28 GPF. PROVIDE WITH

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DOCUMENT 00 9113 ADDENDA SPECIFICATION …...JET TOILET - FLOOR OUTLET - ADA COMPLIANT ACORN ENGINEERING COMPANY PENAL -WARE 1695-W-3-HET-FVL-ADA FV WALL SUPPLY 1.28 GPF. PROVIDE WITH

San Pablo Park Restroom Renovation Specification No. 18-11210-C

Addenda 00 9113-1

DOCUMENT 00 9113

ADDENDA

SPECIFICATION NO. 18-11210-C

CITY OF BERKELEY

SAN PABLO PARK RESTROOM RENOVATION

2800 PARK ST., BERKELEY, CA 94702

The following Addenda were issued, modifying the Project Manual:

Addendum No. 1, issued on August 28, 2018

(Addenda have been incorporated into the conformed Project Manual.)

END OF DOCUMENT

Page 2: DOCUMENT 00 9113 ADDENDA SPECIFICATION …...JET TOILET - FLOOR OUTLET - ADA COMPLIANT ACORN ENGINEERING COMPANY PENAL -WARE 1695-W-3-HET-FVL-ADA FV WALL SUPPLY 1.28 GPF. PROVIDE WITH

ADDENDUM Addendum No.1

08/27/2018 ELS Project No. 201320.20

PROJECT: San Pablo Restroom Remodel OWNER: City of Berkeley CONTRACT: Issue Set

ARCHITECT: ELS Architecture and Urban Design

Description:

The following items are additions, revisions or clarifications to the Permit Set dated January 9, 2018.

ITEM DESCRIPTION

GENERAL

Sheet A201

1. Added dimension on Floor Plan (Detail 2) between urinal screen F11 and Partition Door F6 and between first and second F11 urinal screen in Men Rm. 101

2. Additional clearance dimensions added as well as existing overall dimensions provided for reference.

Sheet A401

1. Removed Restroom Accessory T05 from accessory schedule and where shown on interior elevations.

Sheet MP102

1. Plumbing fixture schedule updated to show correct model numbers for WC-1 and WC-2

Sheet MP201

1. WC-1 and WC-2 designation added to WC’s on Floor Plan 3 (Plumbing).

End of Addendum

Page 3: DOCUMENT 00 9113 ADDENDA SPECIFICATION …...JET TOILET - FLOOR OUTLET - ADA COMPLIANT ACORN ENGINEERING COMPANY PENAL -WARE 1695-W-3-HET-FVL-ADA FV WALL SUPPLY 1.28 GPF. PROVIDE WITH

CITY OF BERKELEY

PARKS, RECREATION & WATERFRONT

1947 CENTER STREET, 4TH FLOOR

BERKELEY, CA 94704

Page 4: DOCUMENT 00 9113 ADDENDA SPECIFICATION …...JET TOILET - FLOOR OUTLET - ADA COMPLIANT ACORN ENGINEERING COMPANY PENAL -WARE 1695-W-3-HET-FVL-ADA FV WALL SUPPLY 1.28 GPF. PROVIDE WITH

CITY OF BERKELEY

PARKS, RECREATION & WATERFRONT

1947 CENTER STREET, 4TH FLOOR

BERKELEY, CA 94704

Eduardo
Snapshot
Page 5: DOCUMENT 00 9113 ADDENDA SPECIFICATION …...JET TOILET - FLOOR OUTLET - ADA COMPLIANT ACORN ENGINEERING COMPANY PENAL -WARE 1695-W-3-HET-FVL-ADA FV WALL SUPPLY 1.28 GPF. PROVIDE WITH

AIR MAX

FLOW TSP MAX SOUND WT

SYMBOL AREA SERVED MFR MODEL TYPE DRIVE

(CFM) (IN H2O)

RPM

(SONES)

VOLTS PH MHP

(LBS)

NOTES

EF-1 MEN'S RESTROOM GREENHECK G-075-VG CENT. DIRECT 210 0.236 1300 3.5 115 1 1/6 48 1

EF-2 WOMEN'S RESTROOM GREENHECK G-075-VG CENT. DIRECT 210 0.236 1300 3.5 115 1 1/6 48 1

NOTES:

1

FAN SCHEDULE

BASIS OF DESIGN ELECTRICAL

PROVIDE CONTROL WIRING. EXHAUST FANS SHALL BE ACTIVATED BY LIGHT SWITCH AND OCCUPANCY SENSOR. COORDINATE WITH ELECTRICAL.

PRIVATE PUBLIC PUBLIC PRIVATE PUBLIC PUBLIC

(.75)

INDIVIDUAL GENERAL HEAVY USE INDIVIDUAL GENERAL HEAVY-USE COLD HOT

DWELLING USE ASSEMBLY DESCRIPTION DWELLING USE ASSEMBLY WATER WATER

0 1 0 DRINKING FOUNTAIN OR WATER COOLER 0.00 0.50 0.75 0.50 ---

0 1 0 HOSE BIBB 2.50 2.50 0.00 2.50 ---

0 3 0

HOSE BIBB, EACH ADDITIONAL

1.00 1.00 0.00 3.00 ---

0 4 0 LAVATORY 1.00 1.00 1.00 4.00 3.00

0 2 0

URINAL, 1.0 GPF

3.00 4.00 5.00 8.00 ---

0 3 0

WATER CLOSET, 1.6 GPF, FLUSHOMETER VALVE

5.00 5.00 8.00 15.00 ---

TOTAL 33.00 3.00

FLOW IN GPM 44 NA

TOTAL GPM REQUIRED44

MAXIMUM FRICTION LOSS

PRESS. AVAIL. X 100'/EQUIV. LENGTH45.600

psi

( E) SERVICE SIZE FROM METER TO BUILDING

2"

WATER SERVICE

CALCULATIONS

(BASED ON APPENDIX 'A' - 2016 CPC)

FIXTURE QUANTITYAPPENDIX 'A' - TABLE A-2.1 TOTAL FIXTURE UNITS

2016 CPC

PUBLIC PRIVATE PUBLIC PUBLIC TOTAL

GENERAL INDIVIDUAL GENERAL HEAVY-USE FIXTURE

USE DESCRIPTION DWELLING USE ASSEMBLY UNITS

0 4 0

LAVATORY, SINGLE

1.00 1.00 1.00 4.00

0 2 0

URINAL, 1.0 GPF

2.00 2.00 5.00 4.00

0 3 0

WATER CLOSET, 1.6 GPF, FLUSHOMETER VALVE

3.00 4.00 6.00 12.00

TOTAL 20.00

PIPE SIZE (EXISTING)

4"

SANITARY DRAINAGE

CALCULATIONS

FIXTURE QUANTITYTABLE 7-3

SYMBOL FIXTURE TYPE DESCRIPTION MFR MODEL ACCESSORIES W V CW NOTES

L-1 LAVATORY

(ADA)

18" LAVATORY WITH OVAL BOWL - ADA

COMPLIANT

ACORN

ENGINEERING

COMPANY

PENAL -WARE 1652-1-LF-

03-M

LAVATORY VALVE PNUEMATICALLY

OPERATED, SET TO 15 SEC., 0.5 GPM FLOW

CONTROL. PROVIDE WITH WALL MOUNTING

HARDWARE.

2" 1-1/2" 1/2" 1,2

WC-1 WATER CLOSET

(ADA)

WALL MOUNTED ELONGATED SIPHON

JET TOILET - FLOOR OUTLET - ADA

COMPLIANT

ACORN

ENGINEERING

COMPANY

PENAL -WARE

1695-W-3-HET-FVL-ADA

FV WALL SUPPLY 1.28 GPF. PROVIDE WITH

WALL MOUNTING HARDWARE, AND SUICIDE

PREVENTION SKIRT.

4" 2" 1-1/2" 1,2

WC-2 WATER CLOSET WALL MOUNTED ELONGATED SIPHON

JET TOILET - FLOOR OUTLET

ACORN

ENGINEERING

COMPANY

PENAL -WARE

1695-W-3-HET-FV

FV WALL SUPPLY 1.28 GPF. PROVIDE WITH

WALL MOUNTING HARDWARE, AND SUICIDE

PREVENTION SKIRT.

4" 2" 1-1/2" 1,2

U-1 URINAL

(ADA)

WALL MOUNTED WASHOUT URINAL ACORN

ENGINEERING

COMPANY

PENAL -WARE

1709HEU-W-1-FVL-ADA

FV WALL SUPPLY 0.125 GPF. PROVIDE WITH

WALL MOUNTING HARDWARE.

2" 1-1/2" 3/4'' 1,2,3

NOTES:

1

2

3

PLUMBING FIXTURE SCHEDULE

BASIS OF DESIGN CONNECTION

SEE ARCHITECTURAL DRAWINGS FOR ALL FIXTURE MOUNTING HEIGHTS AND LOCATIONS. COORDINATE FINISH WITH ARCHITECT.

PROVIDE EXTENSIONS AND REDUCERS AS NECESSARY FOR CONECTION TO EXISTING ROUGH-INS

INSTALL ONE URINAL WITH MAXIMUM LIP HEIGHT OF 15-1/4" FOR ADA.

1

CONTACT

PROJECT

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jan CaroJan Caro

2016-0388

SAN PABLO PARK

RESTROOM RENOVATION

201320 .07

PERMIT SET

JANUARY 9, 2018

CITY OF BERKELEY

PARKS, RECREATION & WATERFRONT

1947 CENTER STREET, 4TH FLOOR

BERKELEY, CA 94704

03/30/18

PLAN CHECK RESPONSE

08/24/18

ADDENDUM #11

MP102

SCHEDULES - MECHANICALAND PLUMBING

Page 6: DOCUMENT 00 9113 ADDENDA SPECIFICATION …...JET TOILET - FLOOR OUTLET - ADA COMPLIANT ACORN ENGINEERING COMPANY PENAL -WARE 1695-W-3-HET-FVL-ADA FV WALL SUPPLY 1.28 GPF. PROVIDE WITH

GENERAL SHEET NOTES

A. INSTALL ALL EQUIPMENT AND FIXTURES PER MANUFACTURER'S

RECOMMENDATIONS.

B. PERFORM CUTTING AND CORE DRILLING WITH MINIMAL DAMAGE TO CONCRETE

STRUCTURE, WALLS AND FLOOR. RESTORE TO MATCH EXISTING CONCRETE

WHEN MECHANICAL AND PLUMBING WORK IS DONE.

SHEET KEYNOTES

1 EF OUTLINE ON THE ROOF.

2 REMOVE EXISTING PLUMBING FIXTURES. PREPARE EXISTING

ROUGH-IN CONNECTIONS FOR NEW FIXTURES.

RE-REOUTE/RE-LOCATE ROUGH-INS AS NEEDED.

3 INSTALL NEW FIXTURES. PROVIDE OFFSETS TO CONNECTIONS AS

NEEDED.

4 (E)

3

4

" GAS AND REGULATOR TO REMAIN. PROVIDE TERMINATION CAP

AND TIGHTEN ALL JOINTS. ENSURE THAT NO LEAKS ARE FOUND.

5 REMOVE EXISTING GAS PIPE.

6 REMOVE (E) SHOWER HEADS INCLUDING ASSOCIATED VALVES AND

PIPES.

7 (E) FIXTURE TO REMAIN. MAINTAIN CW SUPPLY TO THIS FIXTURE.

RE-ROUTE CW SUPPLY PIPE UP HIGH IN THE CEILING. VERIFY CW

CONNECTION AND ROUTING IN FIELD.

8 REMOVE (E) PIPING; CW, GAS AND HW SERVING (E) SHOWERS AND

REMOVE WATER HEATER. CUT WATER DISTRIBUTION PIPES AND CAP

FROM MAIN WATER TIGHT, FLUSH TO FLOOR AND WALLS.

9 REMOVE EXISTING LAVATORY VALVE CONTROLS. INSTALL NEW

CONTROLS FOR NEW VALVES.

10 REMOVE (E) FLUSH VALVES AND REPLACE WITH NEW. PROVIDE

OFFSETS AND TRANSITIONS AS REQUIRED.

11 REUSE EXISTING LOCATION OF FLUSH VALVE LEVERS FOR NEW

LEVERS.

12 CLEAN-UP (E) VALVE BOX TO EXPOSE 2" CW PIPE. REMOVE (E) SOV

AND PIPE FOR NEW SOV CONNECTION.

13 PROVIDE NEW 2" SOV.

14 PROVIDE LOCK FOR VALVE BOX COVER TO SECURE VALVE.

15 MOUNT EF ON ROOF.

16 PROVIDE STOPS AND CAPS OF ALL DEMOLISHED BRANCHES FROM

THIS MAIN CW PIPE. BACKFILL AND RESTORE TO MATCH EXISTING

FLOOR.

17 NEW

3

4

" CW SUPPLY TO EXISTING MOP SINK AND HB. SEE KEYNOTE 7.

18 CW RISER. CONNECT TO (E) MOP SINK AND HB.

19 RELOCATE SS, V, DCW AND ACCESSORIES TO NEW LOCATION ON

3/MP201.

0 4' 8'

SCALE: 1/4"=1'-0"

2'

1 DEMOLITION FLOOR PLAN - MECHANICAL & PLUMBING

0 4' 8'

SCALE: 1/4"=1'-0"

2'

2 FLOOR PLAN - MECHANICAL

0 4' 8'

SCALE: 1/4"=1'-0"

2'

3 FLOOR PLAN - PLUMBING

2

9

2

2

2

2

2

2

1

3

3

3

3

3

3

3

3

3

EF-1 EF-215 15

(E) HB

(E) HB

2

(E) HB

(E) HB

7

(E) 2" CW

(E) VALVE BOX

12

8

7

5

4

6

(E) HB

(E) HB

10

11

11

11

19

19

(E) HB

13 14

(E) MOP SINK

16

1817

1

20

20. VERIFY LOCATION OF (E) BFP & WATER METER

21. SEPARATE BID ITEM 1: ALL WORK INSIDE EXISTING SHOWER ROOMS

AND EXISTING PLUMBING ROOM WILL BE PART OF SEPARATE BID

ITEM 1.

22. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. REPLACE

EXISTING WASTE PIPE WITH NEW 4" AS REQUIRED. USE EXISTING

TRENCH, PATCH & REPAIR FLOOR TO MATCH EXISTING FOR

INSTALLATION OF NEW PIPES

21 21

22

22

2

WC-1

WC-2

WC-1

U-1

U-1

L-1

L-1

L-1

L-1

1

CONTACT

PROJECT

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jan CaroJan Caro

2016-0388

SAN PABLO PARK

RESTROOM RENOVATION

201320 .07

PERMIT SET

JANUARY 9, 2018

CITY OF BERKELEY

PARKS, RECREATION & WATERFRONT

1947 CENTER STREET, 4TH FLOOR

BERKELEY, CA 94704

03/30/18

PLAN CHECK RESPONSE

08/24/18

ADDENDUM #11

MP201

DEMOLITION PLAN & FLOOR PLANS - MECHANICAL & PLUMBING