DMC / total energy metering.ppt slide 1 July 01
DDaniel Measurement & Controlaniel Measurement & ControlDDaniel Measurement & Controlaniel Measurement & Control
KKyoung Su Kimyoung Su Kim
DMC / total energy metering.ppt slide 2 July 01
BUSINESS UNITS
DIVISIONS
Daniel and EmersonDaniel and EmersonDaniel and EmersonDaniel and Emerson
DMC / total energy metering.ppt slide 3 July 01
Daniel is the leading, global supplier of precision flow measurement equipment and instrumentation for gas and liquid petroleum products in:
• production( 생산 ), • distribution( 분배 ), • storage( 저장 ), • and transportation applications( 운송 ).
DMC / total energy metering.ppt slide 4 July 01
The World MarketThe World MarketThe World MarketThe World Market
Whether you are BUYING or SELLING Gas or Liquid Petroleum Products
anywhere in the world ...
the name you can trust is
DMC / total energy metering.ppt slide 5 July 01
Ultrasonic Gas Flow Meters Ultrasonic Gas Flow Meters
DMC / total energy metering.ppt slide 6 July 01
Fundamentals of
Ultrasonic Flow Meters
Fundamentals of
Ultrasonic Flow Meters
DMC / total energy metering.ppt slide 7 July 01
Transit Time MeasurementTransit Time Measurement
Pulser Receiver Detector
Clock
Intrinsically Safe Transducer Signal Loop
100 MHz Oscillator
120 kHz Ultrasonic Signal
( Well Above Control Valve Interference at 60 kHz)
DMC / total energy metering.ppt slide 8 July 01
Ultrasonic TransducerUltrasonic Transducer
BackingMaterial
ElectricalLeads Piezoelectric
Disk
MatchingLayer(s)
Case
Voltage Output
120 KHz In
120 KHz Out
Intrinsically Safe24v DC input
DMC / total energy metering.ppt slide 9 July 01
Ultrasonic Flow MeterUltrasonic Flow Meter
Transit Time .004
LFlow
X
D
Transit Time .007 .003
DMC / total energy metering.ppt slide 10 July 01
Flow Equations
Any pair of transducers
Flow Equations
Any pair of transducers
tup = L
c - v(x/L)
tdn = L
c + v(x/L)
L
Flow
X
D
DMC / total energy metering.ppt slide 11 July 01
Flow Equations
Flow is determined from transit times
Flow Equations
Flow is determined from transit times
v =L2x
(t1-t2)
t1t2
c = L2
(t1+t2)t1t2
v = flow velocityc = speed of sound
t1 = upstream transit time (tup)t2 = downstream transit time (tdn)
2
DMC / total energy metering.ppt slide 12 July 01
Flow Velocity Measurement
Flowrate derived from velocity and area measurement
Flow Velocity Measurement
Flowrate derived from velocity and area measurement
Flowrate = Velocity times Area
DMC / total energy metering.ppt slide 13 July 01
SeniorSonic Calculation
Multipath means multiple velocity measurements!
SeniorSonic Calculation
Multipath means multiple velocity measurements!
Multipath Meter
A
B
C
D
Vn = L2 (t1-t2) 2x(t1t2)
Vavg = Wn Vn
4
n=1
DMC / total energy metering.ppt slide 14 July 01
Geometric Weighting Factors
Fixed factors depend on geometry only!
Geometric Weighting Factors
Fixed factors depend on geometry only!
Multipath Meter
A
B
C
D
WA= 0.1382WB= 0.3618WC= 0.3618WD= 0.1382
DMC / total energy metering.ppt slide 15 July 01
Chordal Velocity MeasurementChordal Velocity MeasurementChordal Velocity MeasurementChordal Velocity Measurement
AB
CD
DMC / total energy metering.ppt slide 16 July 01
Multipath Flowrate Calculation
Steps to determining flowrate
Multipath Flowrate Calculation
Steps to determining flowrate
• Measure transit times for each path
• Calculate velocity for each path (A/B/C/D)
• Calculate "average" velocity
• Multiply velocity by meter body area
DMC / total energy metering.ppt slide 17 July 01
Flow Profile EffectsPower law velocity profile
N=5N=7N=9N=11N=15
Gas velocity is a function of position in pipe
V(r) = Vo (1-r/ro)1/n
Why Multiple Paths ?
DMC / total energy metering.ppt slide 19 July 01
Path Average vs Flow Average
Individual Path Velocity is Average for that Path
DMC / total energy metering.ppt slide 20 July 01
Chordal Velocity MeasurementChordal Velocity MeasurementChordal Velocity MeasurementChordal Velocity Measurement
DMC / total energy metering.ppt slide 21 July 01
Chordal Velocity MeasurementChordal Velocity MeasurementChordal Velocity MeasurementChordal Velocity Measurement
DMC / total energy metering.ppt slide 22 July 01
Chordal Velocity MeasurementChordal Velocity MeasurementChordal Velocity MeasurementChordal Velocity Measurement
AB
CD
DMC / total energy metering.ppt slide 23 July 01
Failed Chord Test Results – 4 inch MeterFailed Chord Test Results – 4 inch MeterFailed Chord Test Results – 4 inch MeterFailed Chord Test Results – 4 inch Meter
-0.20
-0.15
-0.10
-0.05
0.00
0.05
0.10
0.15
0.20
0 30 60 90
Velocity (ft/sec)
Err
or
(%)
Repeat Data
Failed Chord Data Difference = +0.008%
DMC / total energy metering.ppt slide 24 July 01
Summary of Inactive Path Results Summary of Inactive Path Results (19 meters)(19 meters)Summary of Inactive Path Results Summary of Inactive Path Results (19 meters)(19 meters)
SeniorSonic CEESI Inactive Path Results
-0.5
-0.4
-0.3
-0.2
-0.1
0.0
0.1
0.2
0.3
0.4
0.5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Meter
Err
or
(%)
Average = 0.079%
DMC / total energy metering.ppt slide 25 July 01
Flow Rate CalculationsFlow Rate Calculations
Flow Rate is Determined from Velocity Measurement
All Flow Information is Dependent on Correct Transit Time Measurement
Transit Time Measurements are Performed by Electronic Means
DMC / total energy metering.ppt slide 26 July 01
CUI Software
PC based interface programWindows 95,98, NT, XP & 2000
Access flow data and diagnostics
Remote access via dialup modem
Built-in waveform viewerno need for oscilloscope
DMC / total energy metering.ppt slide 28 July 01
Product Improvements
Mark III Electronics w/DFI cardAudit trailDual Serial communication portsFrequency outputs
DMC / total energy metering.ppt slide 29 July 01
Electronics Feature Summary
862 Hourly and Daily records
2849 Audit & 3640 Alarm records
Dual Modbus RS-232/485 multi-drop
Four frequency outputs (configurable)
P&T inputs (Compensated) and analog output
AGA 8 compressibility for corrected volume
Bi-directional meter factors
DMC / total energy metering.ppt slide 30 July 01
Electronics Feature Summary (Cont.)
Configurable for control valve noise
24 Vdc or 110/220 Vac operation
Remote access capability
Replaceable transducer wiring
One electronics for all models
DMC / total energy metering.ppt slide 31 July 01
Entire Electronics – CPU, DFI & PSEntire Electronics – CPU, DFI & PS
DMC / total energy metering.ppt slide 33 July 01
Summary of Summary of Gas Gas Ultrasonic MUltrasonic Meter eter ((SeniorSonicSeniorSonic))
Diameter range: DN 100 - 1050 (4”-42”)
Std Operating Temp: -20 to +100 ºC
Pressure range: Up to 2500# ANSI Class
Measurement channels: 4 Path(8 Transducer)
Explosion Proof: EEx d ia IIB T4(ATEX)
Accuracy limits: Dry calibration +/- 0.30%
Flow calibration +/- 0.10%Repeatability: <0.05% of reading
Velocity range: 0.3m/s to 30+m/s
Turndown: Greater than 100 to 1
Features: Bi-Directional Flow availableP / T input( Compensation)Retractable TransducersReplaceable Transducer Wiring
Diameter range: DN 100 - 1050 (4”-42”)
Std Operating Temp: -20 to +100 ºC
Pressure range: Up to 2500# ANSI Class
Measurement channels: 4 Path(8 Transducer)
Explosion Proof: EEx d ia IIB T4(ATEX)
Accuracy limits: Dry calibration +/- 0.30%
Flow calibration +/- 0.10%Repeatability: <0.05% of reading
Velocity range: 0.3m/s to 30+m/s
Turndown: Greater than 100 to 1
Features: Bi-Directional Flow availableP / T input( Compensation)Retractable TransducersReplaceable Transducer Wiring