1 ELECTRICAL LEGEND
LEGENDELECTRICAL SYMBOLS
PE
JSPK
C
J
J
M
SIGN
FF
M
M EF
SF
F.B.C.
U.N.O.
W.P.
G.F.I.
A.F.F.
A.F.C.
E
3
WP/GFI
24"
D
A
P
NL
B1
WP
JSD
DATA OUTLET, HEIGHT AS NOTED ON PLANS WITH 3/4 " EMPTYCONDUIT TO ABOVE CEILING. PROVIDE PULL WIRE.
1. SCOPE: PROVIDE ALL LABOR, MATERIAL, AND EQUIPMENT IN ACCORDANCE WITH THESESPECIFICATIONS, AND THE ACCOMPANYING DRAWINGS TO PROVIDE A COMPLETE ANDPROPERLY OPERATING ELECTRICAL SYSTEM FOR THE BUILDING.
A. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL OF THE FOLLOWING MATERIAL ANDEQUIPMENT UNDER THIS DIVISION OF THE SPECIFICATIONS, UNLESS NOTED OTHERWISE:PANELBOARDS; LIGHTING FIXTURES; LAMPS; RACEWAYS; 600 VOLT WIRE AND CABLE; WIRINGDEVICES; DEVICE PLATES; DEVICE, PULL, AND JUNCTION BOXES; SAFETY SWITCHES; MOTORSTARTERS; LIGHTING CONTROLS; CIRCUIT BREAKERS; FUSES; TIME CLOCKS; EQUIPMENTIDENTIFICATION (NAMEPLATES AND DIRECTORIES); WIRE AND CABLE TERMINATIONS;CONNECTIONS TO INDIVIDUAL UNITS OF EQUIPMENT FOR THE WALK-IN FREEZERS ANDCOOLERS; AND TEMPORARY POWER.
B. THE FOLLOWING MATERIAL AND EQUIPMENT WILL BE FURNISHED AND/OR INSTALLED BYOTHERS, OR UNDER OTHER DIVISIONS OF THE SPECIFICATIONS, UNLESS NOTED OTHERWISE:LOW VOLTAGE (24 VOLT) WIRE AND CABLE, COMMUNICATION DEVICES, SECURITY EQUIPMENT,POINT OF SALE (POS) EQUIPMENT, SIGNAGE, CONCRETE BASES FOR SITE LIGHTING POLES.
C. THE FOLLOWING MATERIAL AND EQUIPMENT WILL BE FURNISHED BY OTHERS, OR UNDEROTHER DIVISIONS OF THE SPECIFICATIONS, AND INSTALLED BY THE CONTRACTOR, UNLESSNOTED OTHERWISE: SITE LIGHTING FIXTURES AND POLES.
2. GENERAL REQUIREMENTS: ALL WORK SHALL BE PERFORMED BY SKILLED LICENSEDELECTRICIANS IN ACCORDANCE WITH THE BEST PRACTICES OF THE TRADE, MEETING THEREQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, APPLICABLEFEDERAL, STATE AND LOCAL CODES, AND THE REQUIREMENTS OF THE ELECTRICAL UTILITYCOMPANY FURNISHING THE SERVICES. ALL NECESSARY CONSTRUCTION PERMITS ANDCERTIFICATES OF INSPECTION SHALL BE PURCHASED AND OBTAINED UNDER THIS CONTRACT.
A. COORDINATION: ALL OUTLETS MUST BE ACCURATELY LOCATED, PARTICULARLY APPLIANCEOUTLETS WHICH SHALL BE LOCATED FROM THE DIMENSIONS GIVEN ON THE DRAWING ANDFIELD VERIFIED. REVIEW THE ARCHITECTURAL, PLUMBING AND HEATING AND VENTILATINGPLANS IN ORDER TO COORDINATE THIS WORK WITH OTHER TRADES, AND COOPERATE WITHTHEM IN THE ENTIRE INSTALLATION.
3. SERVICE VOLTAGE: THESE DRAWINGS ARE FOR A METERED, UNDERGROUND BUILDINGSERVICE OF 120/208 VOLT, THREE PHASE, FOUR WIRE, 60 HERTZ. ALL KITCHEN AND AIRCONDITIONING EQUIPMENT HAS BEEN DESIGNED AND PURCHASED FOR USE ON THISELECTRICAL SYSTEM. THE CONTRACTOR SHALL CONTACT THE ELECTRICAL UTILITY ANDVERIFY ALL OF THE ABOVE SERVICE CHARACTERISTICS, AND THE AVAILABLE FAULT CURRENT.
4. SERVICE EQUIPMENT: THE SERVICE SHALL BE LOCATED AS SHOWN ON THE SITE PLAN, OR ASINDICATED IN THE INSTRUCTIONS TO BIDDERS. UTILITY POLES, PADS FOR UTILITYTRANSFORMERS, CURRENT TRANSFORMER ENCLOSURES, METERING EQUIPMENT, SERVICEMASTS, AND OTHER RELATED MATERIALS AND EQUIPMENT SHALL BE APPROVED, FURNISHED,AND INSTALLED AS REQUIRED. INCLUDE THE COST OF ALL THE ABOVE ITEMS, SERVICECONNECTIONS, AND METER CHARGES IN THE BASE BID. MAIN SERVICE SWITCHES ANDCURRENT TRANSFORMER CABINETS SHALL BE INCLUDED IN THE BASE BID. UNLESS NOTEDOTHERWISE, A MAIN SERVICE SWITCH WITH CURRENT LIMITING FUSES MAY BE USED WHENTHE AVAILABLE FAULT CURRENT (AFC) IS EXCESSIVE, IN ORDER TO USE STOCKPANELBOARDS, WITH 10K OR 22K AIC RATINGS.
PART II. MATERIALS
1. MATERIALS: ALL MATERIALS SHALL BE NEW AND OF THE QUALITY INDICATED BY THESPECIFIED BRAND NAMES. SUBSTITUTIONS OF MATERIAL OF EQUAL QUALITY BY OTHERMAJOR MANUFACTURERS OF COMMERCIAL EQUIPMENT MAY BE ACCEPTABLE PROVIDED ALIST OF SUCH SUBSTITUTIONS IS APPROVED IN WRITING BY POPEYE'S ARCHITECTURE ANDENGINEERING DEPARTMENT. THE CONTRACTOR SHALL SUBMIT A SUBSTITUTION LIST INTRIPLICATE AT LEAST FIVE DAYS PRIOR TO THE BID OPENING.
SINGLE FACE EXIT LIGHT W/EMERGENCY BATTERYPACK AND TWO (2) EMERGENCY LIGHT HEADS. SEEFIXTURE SCHEDULE
BRACKET OR WALL MOUNTED LIGHT FIXTURE. LETTERDENOTES MARK, SEE FIXTURE SCHEDULE.
FLUORESCENT LIGHT FIXTURE. LETTER DENOTESMARK. SEE FIXTURE SCHEDULE.FLUORESCENT LIGHT FIXTURE ON NIGHT LIGHT CIRCUIT.
FLUORESCENT LIGHT FIXTURE. LETTER DENOTESMARK. SEE FIXTURE SCHEDULE.PENDANT LIGHT FIXTURE. LETTER DENOTESMARK. SEE FIXTURE SCHEDULE.
RECESSED DOWN LIGHT FIXTURE. LETTER DENOTESMARK. SEE FIXTURE SCHEDULE.8" VERTICAL FLUORESCENT RECESSED LIGHTFIXTURE. LETTER DENOTES MARK. SEE FIXTURESCHEDULE.
TOGGLE SWITCH - SINGLE POLE - HUBBEL #HBL1221-I.
DUPLEX RECEPTACLE; NUMBER SUBSCRIPT INDICATES MOUNTINGHEIGHT ABV FINISHED FLOOR IF DIFFERENT THAN SPECIFIED.HUBBEL #5362-IDUPLEX RECEPTACLE - IN WEATHER PROOF ENCLOSURE ORCOVER, GROUND FAULT INTERUPTER.
RECEPTACLE FLUSH MOUNTED IN CEILING. VERIFYEXACT LOCATION AND NEMA CONFIGURATION.
DUPLEX RECEPTACLE - ISOLATED GROUND SURGEPROTECTED - HUBBELL #IG-5362-OSP FOR POS EQUIP. &PRINTERS
DUPLEX RECEPTACLE - ISOLATED GROUND SURGE PROTECTED;MOUNTED IN CEILING. HUBBELL #IG-5362-OSP FOR MONITORS
SPECIAL PURPOSERECEPTACLE
208/120 PANELBOARD.
DISCONNECT SWITCH SIZE AS NOTED.
DOOR SWITCH MOUNTED IN DOOR FRAME (F.B.C.)
SEE ELECTRICAL NOTES.
ABOVE FINISHED FLOOR.
ABOVE FINISHED CEILING.
GROUND FAULT INTERUPTING
FURNISHED BY CONTRACTOR.
WEATHERPROOF
UNLESS NOTED OTHERWISE.
EXHAUST FAN.
SUPPLY FAN.
FLY FAN
JUNCTION OR OUTLET BOX.
JUNCTION OBOXFOR SIGN-MOUNT SWITCH NEAR SIGN. MAKE ALLCONNECTIONS REQ'D. VERIFY ALL ASPECTS WITH SIGNAGE VENDOR.SEE ARCHITECTURAL ELEVATIONS FOR HEIGHT AND LOCATION ASSHOWN.JUNCTION BOX FOR SMOKE DETECTOR (F.B.C.) 120vWIRING BY THIS CONTRACTOR.
COMBINATION DUAL DATA OUTLET AND TELEPHONE OUTLETHEIGHT AS NOTED ON PLANS WITH 3/4 " EMPTY CONDUIT TOABOVE CEILING. PROVIDE PULL WIRE.
TELEPHONE OUTLET, WALL TYPE, 24" AFF U.N.O ON PLANS WITH3/4 " EMPTY CONDUIT TO ABOVE CEILING. PROVIDE PULL WIRE.
PROVIDE 'ON/OFF' SELECTOR SWITCH AND PILOT LIGHT IN NEMA4 STAINLESS STEEL ENCLOSURE MOUNTED ON THE FACE OFTHE HOOD. PROVIDED BY HOOD MANUFACTURER.
SPEAKER; CEILING MOUNTED
SPEAKER OUTLET IN WALL STUB 3/4" CONDUIT TO SPACEABOVE ACCESSIBLE CEILING. PROVIDE PULL WIRE.
TRANSFORMER MOUNTED ACCESSIBLE
ELECTRIC DOOR PUSHBUTTON: EDWARDS#590 48" MOUNTING HEIGHT
ELECTRIC DOOR BUZZER: 8" BELOW CEILING
PHOTOCELL
6. CONDUIT AND FITTINGS: CONDUITPERMITTED: (A) RIGID GALVANIZED STEEL (RGS),(B) EMT, (C) PVC, AND (D) ENT. TYPESUTILIZED SHALL BE RUN ONLY AS PERMITTEDPER CODE. ALL WIRING SHALL BE RUN INCONDUIT. CONDUIT PLACED IN CONCRETE ORRUN UNDERGROUND SHALL BE RIGIDGALVANIZED CONDUIT OR PVC. IF PVC IS USED,ALL ELBOWS, SWEEPS AND STUB-UPS SHALLBE RGS. CONDUIT EXPOSED OR RUN IN
MASONRY WALLS ABOVE GRADE MAY BEPVC OR EMT WHERE ALLOWED BY LOCALCODES. IF EMT IS NOT PERMITTED, RIGIDSCREWED GALVANIZED PIPE CONDUIT ANDFITTINGS S HALL BE USED. IF SHIELDED CABLEIS REQUIRED FOR CONTROL CIRCUITRY, ITSHALL BE TAN, GREY OR ANY NEUTRAL COLOROTHER THAN THAT AS SPECIFIED FOR POWER
DISTRIBUTION. NO CONDUIT SMALLERTHAN 3/4" SHALL BE INSTALLED EXCEPT FOR
TWO-WIRE SWITCH LEGS. ALL CONDUITBENDS SHALL BE FREE FROM DENTS AND KINKS.
ALL CONDUITS SHALL BE ELECTRICALLYCONTINUOUS FROM THE SERVICE EQUIPMENTTO ALL OUTLETS, AND SHALL BE SECUREDTO ALL METAL BOXES WITH ONE LOCK NUT
OUTSIDE, AND ONE INSIDE THEBOX WITH A REINFORCED BAKELITE BUSHING. IFPVC, OR ENT, IS USED, THEN APPROPRIATESIZED, ELECTRICALLY CONTINUOUS, BONDWIRES SHALL BE RUN FROM THE SERVICEEQUIPMENT TO ALL OUTLETS, AND SHALL BESECURED TO EACH WIRING DEVICE PER THENATIONAL ELECTRICAL CODE. WHERECONNECTIONS ARE TO BE MADE BETWEENCONDUIT TERMINATIONS AND MOTORS,EQUIPMENT, OR APPARATUSNECESSITATING FLEXIBLE CONNECTIONS,APPROVED FLEXIBLE CONDUIT SHALL BEUSED. OUTDOOR CONNECTIONS TO FANS, HVACUNITS, OR ROTATING EQUIPMENTSHALL B MADE WITH HELICAL WOUND,LIQUIDTIGHT, FLEXIBLE STEEL CONDUIT. EXPOSED CONDUIT SHALL BESUITABLY SUPPORTED AT INTERVALS NOT TO
EXCEED FIVE (5) FEET. DURINGCONSTRUCTION, CONDUIT SHALL BE KEPT FREEOF ALL FOREIGN MATTER BY USE OFCAPPED BUSHINGS ON ALL TURNED UP ENDS.PAPER OR WOOD PLUGS ARE NOTACCEPTABLE FOR THIS PURPOSE.
7. WIRE AND CABLES: ALL WIRE ANDCABLES SHALL BE UNDERWRITERSLABORATORIES' LISTED, AND LABELED, ANDCONFORM WITH APPLICABLE STANDARDS OF UL(44, AND 83), NEMA (WC-5, AND WC-7), IPCEA(S-61-402, AND S-66-524), FEDERALSPECIFICATIONS (J-C-30A(1), ANDHH-I-595C), ANSI, AND OTHER APPLICABLEINDUSTRY STANDARDS. CONNECTORS AND LUGS SHALL MEET ULPUBLICATION 486. ALL BRANCH CIRCUIT WIRING
SHALL BE 600 VOLT, COPPER, 75 DEGREEC (MIN), TYPE THHN/THWN WITH A MINIMUM SIZE
OF #12 AWG, UNLESS NOTED OTHERWISE.WIRE SIZES OF #8 AWG AND LARGER SHALL BE
STRANDED. SERVICE AND FEEDERCABLES SHALL BE 600 VOLT, STRANDEDCOPPER, 75 DEGREE C (MIN), TYPE XHHW. ALLCIRCUITS SHALL HAVE A SEPARATE GROUND
CONDUCTOR. PROVIDEGREEN-INSULATED GROUND WIRE IN ALLRACEWAYS, CABLE ASSEMBLIES, AND WHERENOTED. SIZE EQUIPMENT GROUNDS PER TABLE250-122 OF THE NATIONAL ELECTRICALCODE. INSULATION COLOR CODES SHALL BEBLACK, RED, AND BLUE (PHASE), WHITE(NEUTRAL), AND GREEN (GROUND).
A. ALL WIRING SHALL BE INSTALLED INCONDUIT, EXCEPT WHERE SPECIFICALLYSHOWN ON THE DRAWINGS.NON-METALLIC SHEATHED (TYPE NM)CABLE IS NOT PERMITTED.
B. ALL BRANCH CIRCUIT, COMMUNICATION,SIGNALING, AND CONTROL WIRING TOKITCHEN, FIRE PROTECTION, AND OTHEREQUIPMENT SHALL BE ROUTED ABOVE THECEILING. VERIFY WHETHER OR NOT THESPACE ABOVE THE CEILING IS USED AS ASPACE FOR RETURN AIR FOR THEENVIRONMENTAL AIR SYSTEM. IF IT IS
USED FOR RETURN AIR, PROVIDEAPPROVED RACEWAYS FOR ALLOVERHEAD WIRING PER NEC ARTICLE300-22(B). IF IT IS NOT "OTHER SPACE USEDFOR ENVIRONMENTAL AIR", APPROVEDLOW VOLTAGE CABLES MEETING THEREQUIREMENTS OF NEC ARTICLES 725 AND760 MAY BE RUN WITHOUT RACEWAYS,UNO. ALL SAFETY CONTROL WIRING FORFIRE PROTECTION SYSTEMS, SHUNT TRIPS,ETC. SHALL BE RUN IN A RACEWAY INACCORDANCE WITH NEC ARTICLES 725.25AND 725.28.
8. SITE LIGHTING: THE G.C. WILL FURNISHTHE SITE LIGHTING PACKAGE, AS REQUIREDFOR THE SPECIFIC LOCATION. UNDER THISSPECIFICATION SECTION, PROVIDE 1" RIGID
GALVANIZED STEEL ELECTRICALCONDUIT, AND THE REQUIRED WIRING FROMTHE PANEL TO THE POLE. SET FIXTURES ANDPOLES ON CONCRETE BASES, AS PROVIDEDUNDER SPECIFICATION SECTION 3A:CONCRETE. GROUND/BOND ALL SITE LIGHTING
FIXTURES/POLES PER THE NEC.THE BRANCH CIRCUIT CONDUCTORS SHALL BE
INCREASED FROM #10 AWG TO #8AWG IF THE HORIZONTAL DISTANCE FROM THEPANEL TO THE POLE IS GREATER THANEIGHTY (80) FEET. ALL SITE LIGHTING SHALL BE
CONTROLLED THROUGH THELIGHTING CONTROL SYSTEM SHOWN ON THEDRAWINGS. REFER TO THE SITE PLAN FORQUANTITY AND LOCATION OF ALL SITE LIGHTING.SET FIXTURES AS SPECIFIED, AND AIM AFTERDARK FOR UNIFORM LIGHT DISTRIBUTION.
9. SIGNAGE LIGHTING: PROVIDE A 1" RIGIDGALVANIZED STEEL ELECTRICAL CONDUIT, AND
WIRING, FROM THE PANEL TO ALLILLUMINATED SIGNS AS SHOWN ON THELIGHTING AND SITE PLANS.GROUND/BOND EACH SIGN. SIGNS WILL BEFURNISHED AND INSTALLED BY THE OWNER,OR UNDER A SEPARATE CONTRACT, UNO.POWER AND WIRING SHALL BE FURNISHEDAND INSTALLED UNDER THIS SECTION OF THESPECIFICATIONS.
OTHER WIRING:
A. FURNISH AND INSTALL ALL POWER WIRINGAND CONDUIT AS INDICATED ON THEDRAWINGS FOR ROOF-TOP HVACEQUIPMENT, KITCHEN HOOD FANS, ANDWALK-IN FREEZER AND COOLEREQUIPMENT. DISCONNECT SWITCHES,AVAILABLE FROM THE NATIONAL ACCOUNT,SHALL BE FURNISHED AND INSTALLED FOREACH UNIT OF HVAC EQUIPMENT, AND FORKITCHEN EQUIPMENT WITHOUT A CORDAND PLUG. BEFORE ENERGIZING ANYEQUIPMENT, VERIFY THAT THE CORRECTPOWER SUPPLY VOLTAGE, AMPACITY, ANDPHASING HAS BEEN PROVIDED AT THELOAD SIDE OF THE DISCONNECT.
B. FURNISH AND INSTALL THE LIGHTINGCONTACTOR PANEL, AND ALL ASSOCIATEDPOWER WIRING, AS INDICATED. THELIGHTING CONTACTOR PANEL IS CUSTOMBUILT, AND AVAILABLE FROM THENATIONAL ACCOUNT.
10. EMPTY CONDUIT: LEAVE A #12 AWG PULLWIRE IN ALL EMPTY CONDUITS.
A. BOXES AND WIREWAYS: ALL JUNCTIONBOXES, PULL BOXES, WIREWAYS, ETC,SHALL BE SIZED IN ACCORDANCEWITH THE NATIONAL ELECTRICAL CODE.
11. EQUIPMENT IDENTIFICATION: PROVIDENAMEPLATES FOR ALL PANELBOARDS,CONTROLS, AND OTHER ELECTRICALEQUIPMENT. EQUIPMENT VISIBLE TO THEPUBLIC SHALL BE IDENTIFIED WITHENGRAVED LAMINATED NAMEPLATES ATTACHEDWITH STAINLESS STEEL FASTENERS.ELECTRICAL EQUIPMENT NOT VISIBLE TO THEPUBLIC MAY BE NEATLY IDENTIFIED WITHBLACK PERMANENT MARKERS.
BALCONY UPLIGHT FIXTURE
9 ELECTRICAL SPECIFICATIONS
DIVISION 16 - ELECTRICAL SPECIFICATIONS
PART I. GENERAL PROVISIONS
A. PANELBOARDS: PANELBOARDS SHALL BE BOLT-IN CIRCUIT BREAKER TYPE, AS SHOWN ONTHE PLANS. PANELS SHALL BE OF PANELBOARD CONSTRUCTION, 20 INCHES WIDE(MINIMUM), 5-3/4" TO 6-1/2" DEEP, UL LISTED, AND MEET UL 67, UL 50, AND FEDERALSPECIFICATION W-P-115B AS TYPE 1, CLASS 1, WITH BOLT-ON CIRCUIT BREAKERS, COPPERBUS BARS, NEUTRAL BUS, GROUND BUS, AND A HINGED LOCKABLE DOOR. CABINETSSHALL BE CODE GAUGE, GALVANIZED STEEL, MOUNTED AS SHOWN. PROVIDETYPEWRITTEN CIRCUIT DIRECTORIES WITH CLEAR PLASTIC PROTECTORS IN ALL PANELS.ALL WIRES SHALL BE TAGGED WITH PANEL AND CIRCUIT NUMBERS. PANEL "MP" SHALL BEUL LISTED AND LABELED AS SUITABLE FOR USE AS SERVICE ENTRANCE EQUIPMENT.APPROVED MANUFACTURERS OF PANELS ARE SQUARE D/TELEMECHANIQUE,CUTLER-HAMMER, GENERAL ELECTRIC, WESTINGHOUSE, AND SIEMENS (I-T-E).
B. LIGHTING FIXTURES: ALL LIGHTING FIXTURES SHALL BE UL LISTED, COMMERCIALQUALITY. REFER TO NATIONAL ACCOUNT SCHEDULE. REVIEW AT:WWW.POPEYESDEVELOPMENT.COM; PASSWORD: lagniappe
C. LAMPS: ALL NEW FLUORESCENT LAMPS (F40T8) SHALL BE COOL WHITE, OR COLORIMPROVED COOL WHITE, WITH A 4100 DEGREE K COLOR TEMPERATURE, 2950 MIN INITIALLUMENS, 20,000 HOURS RATED LIFE, AND 62 MIN CRI, UNLESS NOTED OTHERWISE.
D. WIRING DEVICES: ALL WIRING DEVICES SHALL BE UL LISTED, COMMERCIALSPECIFICATION GRADE. SWITCHES SHALL BE RATED 20 AMPS AT 120/277 VOLTS, AC.STANDARD RECEPTACLES SHALL BE 20 AMP, DUPLEX,GROUNDING TYPE, IN NEMACONFIGURATIONS, UNLESS NOTED OTHERWISE. SWITCHES IN THE SAME LOCATION SHALLBE GANGED BEHIND A SINGLE PLATE. DEVICE PLATES IN THE KITCHEN AREA SHALL BEMETAL, ALUMINUM OR STAINLESS STEEL. DEVICE PLATES IN THE DINING AREA SHALL BETHERMOPLASTIC PLASTIC (NYLON) OR METAL, COLOR AS APPROVED BY THE ARCHITECTOR OWNER. APPROVED MANUFACTURERS OF SWITCHES AND RECEPTACLES AREHUBBELL, ARROW HART, BRYANT, LEVITON, PASS & SEYMOUR, GENERAL ELECTRIC,SLATER, OR EQUAL.
1. SWITCHES:a. SINGLE POLE: HUBBELL HBL1221-I, OR EQUAL.b. THREE WAY: HUBBELL HBL1223-I, OR EQUAL.
2. RECEPTACLES:a. NEMA 5-20R: HUBBELL 5362I, OR EQUAL.b. NEMA 5-20R-IG: HUBBELL IG-5362, OR EQUAL.c. NEMA 5-20R-IG/SS: HUBBELL IG-5362-OS, OREQUAL.d. NEMA 5-20R-GFCI: HUBBELL GF5362-I, OR EQUAL.e. NEMA 6-20R: HUBBELL 5462-I, OR EQUAL.f. OTHERS: COMMERCIAL OR INDUSTRIAL GRADE, UL LISTED, FEDERAL
SPECIFICATION WC596F.
3. WP PLATES: WEATHERPROOF COVERS ARE PERMITTED UNDER NEC ARTICLE 406.8(B)(I).
4. NATIONAL ACCOUNT: REFER TO THE NATIONAL ACCOUNT DIRECTORY. THE FOLLOWINGEQUIPMENT MAY BE AVAILABLE: MAIN SERVICE PANELBOARD WITH BREAKERS INSTALLED,LIGHTING AND DISTRIBUTION PANELBOARDS WITH BREAKERS INSTALLED, ROOF-TOPDISCONNECTS FOR HVAC UNITS AND KITCHEN HOOD FANS, LIGHTING CONTACTOR PANEL,AND SHUNT TRIP SYSTEMS (IF REQUIRED PER LOCAL CODE).
5. EXCAVATIONS: PERFORM ALL NECESSARY EXCAVATING AND BACK-FILLING REQUIREDFOR THIS INSTALLATION. ALL EXCAVATIONS BELOW THE BOTTOM OF FOOTINGS SHALL BEBACKFILLED WITH 3000 PSI CONCRETE. WHERE DITCHES ARE CUT FOR OUTSIDE RUNS OFCONDUIT, REPLACE AND TAMP THE EARTH IN 12" LAYERS AND LEAVE THE GROUND LEVELAND EQUAL TO ITS ORIGINAL CONDITION.
PART III. EXECUTION
1. TESTS: MAKE ALL TESTS NECESSARY TO ENSURE THAT THE ENTIRE INSTALLATION IS FREEFROM IMPROPER GROUNDS, AND FROM SHORTED AND/OR OPEN CONDUCTORS. VOLTAGE,CURRENT, AND ROTATION TESTS SHALL BE MADE BEFORE ANY MOTORS ARE PLACED INOPERATION. ALL LOADS SHALL BE BALANCED ACROSS PHASES. CHECK TO SEE THAT ALLLIGHTS WORK, AND ARE CONTROLLED BY SWITCHES INDICATED ON DRAWINGS, OR CIRCUITBREAKERS SO INDICATED ON PANEL SCHEDULE.
2. GUARANTEE: FURNISH A GUARANTEE IN WRITING TO THE OWNER THAT ALL WORK EXECUTEDUNDER THIS SECTION IS FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR APERIOD OF ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE. IN ADDITION, DURING THE TERMOF THIS GUARANTEE, THE REPAIR AND/OR REPLACEMENT OF ANY DEFECTIVE WORK, AND ALLRESULTING DAMAGES SHALL BE MADE AT NO ADDITIONAL EXPENSE TO THE OWNER.
3. TEMPORARY POWER: AT THE PROJECT SITE, PROVIDE A 100 AMP, 120/240 VOLT, SINGLE PHASE,SERVICE WITH POWER OUTLETS ADEQUATE FOR TEMPORARY CONSTRUCTION POWER.TEMPORARY LIGHTING SHALL BE MAINTAINED IN ALL AREAS OF THE BUILDING UNTILPERMANENT POWER SOURCES HAVE BEEN ENERGIZED. TEMPORARY SERVICE SHALL BEPROVIDED UNDER SECTION 1A OF THESE SPECIFICATIONS.
4. CLEAN-UP: LEAVE THE ELECTRICAL PORTION OF THE WORK IN A CLEAN AND FINISHEDCONDITION.
5. SHOP DRAWINGS: PROVIDE SHOP DRAWINGS FOR THE FOLLOWING ITEMS: PANELBOARDS,LIGHTING FIXTURES.
6. AS-BUILT DRAWINGS: MAINTAIN AS-BUILT DRAWINGS, UPDATED DAILY DURING CONSTRUCTION,AND PRESENT THE OWNER WITH ONE SET UPON COMPLETION. PROVIDE THE OWNER'SPERSONNEL WITH ON-SITE INSTRUCTION IN THE OPERATION AND MAINTENANCE OF THECOMPLETED ELECTRICAL SYSTEM.
DESIGNPARAMETERS, LLC
10495 S PROGRESS WAY #202PARKER, CO 80134PH: 303.668.1474FX: 303.223.9104
DESIGNPARAMETERS.COM
EX
EX 11
A-18
EX
NL
EXER
CC
NL
NL NL
LL4
C
C
C
LL4
LL4
LL4
LL4
LL4
LL266"AFF
LL4
aLL4
aa a
a
a a
a a
a a a a
LL4 LL4 LL4
LL266"AFF
C
C
a
LL4
a
LL4
d
a
a
NL
LL4
LL4 LL4
A-18
a
LL4
a
LL4
aLL4
a
LL4
a
LL4
a
a
a
d
LL284"AFFe
LL284"AFFe
LL284"AFFe
LL284"
e
eLL4
e
LL4
Ca
Ca
Ca
e
LL4
e
LL4
b
b
b
LL4
LL4
LL4
LL1
b
LL4
LL4
EX
CL
8
11
H B-38
B-38
B-38
11
B-28
SIGN
B-30H
B-30
B-30H
11
11
H
H B-38
H B-38
H B-38
H B-38
B-15
HB-28
ER HB-28
H
B-28
B-30E
B-28EB-28EB-28E
B-28E
B-30E
B-30E
B-30E
A-32,34,36,38,40,42 VIA LC2# 8'S
WP
B-19:21 VIA LC1
WP
TO SITE LIGHTING - TYPICAL.SEE SITE PLAN TO VERIFYLOCATION AND QUANTITY.SEE NOTE 7
PYLON SIGN - REFERTO SITE PLAN FOR SEENOTES 5 & 7
LL3
LL3
LL3
LL3
LL3
LL3 LL3
B-32
SPR
B-32H
J-BOX FOR SPEAKER AT 10'-4"A.F.F., CENTERLINE
B-32E
B-32E
B-32E
B-32D
D1B-32
B-30
B-32H
D1B-32
D1B-32
B-32D
A-18B-16,18VIA LC-1 24
D/T MB PB
1818
VERIFY LOCATIONON SITE PLAN
PREVIEW BOARD ONCLEARANCE SIGN
DRIVE-THRU MENU BOARD
B-16TO DIRECTION SIGNS. VERIFY LOCATIONSAND QUANTITY OF SIGN ON SITE PLAN.
d
d
NL
NL
A
A
AA A
NL
c
ccEX
DP B A C
PC
LTG CONT. LC-1, 2 & 3CONTACTORS, SEE
DIAGRAM THIS SHEET &POWER RISER SHEET E3.
J-BOX FOR SPEAKER AT14'-6" A.F.F., CENTERLINE
1
ER
WP
LL4LL4
LL4 LL4
LL4 LL4
LL4
LL4
LL4LL4
B-7
B-7
b
b
1
1
SPR
LOCATE SEL. SWITCHCONTROLS FOR LC-1, LC3LIGHTING CONTACTORS, ANDPUSHBUTTON CONTROL FORLC-2 LIGHTING CONTACTOR ATTHIS LOCATION
LOCATE LIGHTING AND FANON/OFF CONTROL SWITCHES"a, b, c, d & e" AT THIS LOCATION
J-BOX FOR SPEAKER AT 14'-6"A.F.F., CENTERLINE
B-16 DIR SIGNS
N
B-20
PEOFF
ON
AUTO
OPTIONAL
PE
A-32
NO
R1
NC
OFF
PARKING
B-15
B-18
B-21
B-19
SPARE
B-38
SPARE
LC1
PYLON SIGN
MENU BOARD
PYLON SIGN
SIGN BLDG FRT
A-34
A-36
A-40
A-38
A-42
WALL ART SPARE
SPARE
PARKING
PARKING
PARKING
PARKING
PARKING
LC2
ON ROOFCONTROL MOUNTEDREMOTE PE
120V
N
B-7
H
PEWP
FIXTURELIGHT
OFF
ON
AUTO
CONTACTOR DIAGRAM NOTES:
B-28
B-30
B-32 CANOPY LIGHTS
CANOPY LIGHTS
CANOPY LIGHTS
SPARE
SPARE
SPARE
LC3
10
13
12
11
9
8
4
7
6
5
2
3
1
LABOR INCLUDES INSTALLATION OF 150' OF 12 GAUGE SPEAKER WIRE.NUMBER OF SPEAKERS MAY VARY DUE TO DESIGN CONSIDERATIONS
CHANNEL MASTER
ECOHO STAR
PASO
QUAM
QUAM
VARIOUS
***
1.0 ANTENNA
3000
VARIOUS
QC-10
1
1
1
3
701
MODEL #16, BLACK
OWI
SSB-2
ERD-8
MU 3130 BGM
MAKE
BOSE
MODEL
4
2
2
1
QUANTITY
4
MUZAK MBS 8-ST3, BLACK 2
QUAM
SEE THE NATIONAL ACCOUNT VENDOR LIST FOR EQUIPMENT SUPPLIER.
1. THE LIGHTING CONTACTORSSHALL BE HELD MAGNETICALLYIN A NEMA 1 ENCLOSURE. THESIGN & CANOPY LIGHTING SHALLBE SET TO COME ON FIRST,EVEN ON RAINY/CLOUDY DAYSAND THE PARKING LOT LIGHTINGSHALL BE SET TO COME ONLATER. THE CONTROLS SHALLBE WIRED SO THAT EACHGROUP OF LIGHTING(SIGNAGE/CANOPY ADNPARKING LOT) IS INDEPENDENT,AND MAY BE MANUALLYSWITCHED OFF AT CLOSINGWITH ITS SELECTOR SWITCH VIATIME DELAY RELAY - SEECONTACTOR DIAGRAM DETAILTHIS SHEET.
R1
RECESSED SPEAKERS* (DINING)
RECESSED SPEAKERS* (KITCHEN)
OUTDOOR BOX SPEAKERS*
AMPLIFIER
SPEAKER SUPPORT
SPEAKER BACKCANCABLE, CONNECTORS,HARDWARE AND SHELF
AREA VOLUME CONTROL
RECEIVER
DISH
# 8'S
LL1
b
POPEYES RADIO SYSTEMDESCRIPTION
SET FOR DARK, MOUNTON ROOF FACING NORTH(TYPICAL)
PROVIDE PUSHBUTTONSQUARE D #9001 KR1 RH13& #9001KN202 "OFF"LEGEND
PROVIDE DPDT RELAY SQUARE D#8501-KP12V20 & #8501 NR51 BASE ANDADJUSTIBLE TIMER & BLOCK SET FOR 30MIN TIME DELAY WHEN TURNED OFF.
LIGHTING CONTACTOR W/ 8 POLESAT 30 AMP EACH (TYPICAL) SD D#8903-LG80VO2 NOMINAL ENCL.DIMENSIONS- 8" W x 13" H x 6" D
LIGHTING CONTACTOR W/ 6 POLESAT 20 AMP EACH (TYPICAL) SD D#8903-LG80VO2 NOMINAL ENCL.DIMENSIONS- 8" W x 13" H x 6" D
LIGHTING CONTACTOR W/ 8 POLESAT 20 AMP EACH (TYPICAL) SD D#8903-LG80VO2 NOMINAL ENCL.DIMENSIONS- 8" W x 13" H x 6" D
SET FOR DUSK ORRAINY/CLOUDY DAYS; MOUNTON ROOR FACING NORTH(TYPICAL)
NOTES:1. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, EXTERIOR ELEVATIONS ANDWALL SECTIONS FOR DIMENSIONED LOCATIONS OF LIGHTING FIXTURES.
2. CRABPOT LIGHTS AT "P" COUNTER TO BE MOUNTED 84" ABOVE FINISH FLOOR.PENDANT and CRABPOT LIGHTS AT TABLES TO BE MOUNTED 66" ABOVE FINISH FLOOR.
ALL "EX" EMERGENCY & EXIT LIGHTING FIXTURES SHALL BE CONNECTEDAHEAD OF ROOM/AREA SWITCHES PER NATIONAL ELECTRICAL CODE (NEC)ARTICLE 700-12(f)
VERIFY THE EXACT LOCATION OF SIGNS, AND FASCIA BOXES BEFOREINSTALLATION OF JUNCTION BOXES.
HOMERUNS MAY BE COMBINED AS ALLOWED BY THE NATIONAL ELECT.CODE ALL CONDUIT SHALL BE SIZED PER THE 2011 NEC.
ELECTRICAL CONTRACTOR SHALL VERIFY EXACT SIGN(S) WIRINGREQUIREMENTS WITH THE SIGN SUPPLIER PRIOR TO SUBMITTING A BID FORTHE ELECTRICAL.
ELECTRICAL CONTRACTOR SHALL VERIFY THE LOCATION OF THE PYLONSIGN ON THE SITE PLAN.
PROVIDE 2P/30A NEMA 3R, FUSED DISCONNECT SWITCH W/ LIQUID-TIGHTFLEXIBLE CONNECTION TO PYLON SIGN. FUSE SIZE PER SIGN MFR'SRECOMMENDATION.
THE BUILDING SIGNAGE, PYLON SIGN, FASCIA LIGHTING, BUILDING SIGNLIGHTING, DRIVE-THRU MENUBOARD(S), AND SITE LIGHTING SHALL BEWIRED THRU THE LIGHTING CONTACTORS FOR AUTOMATIC & MANUALCONTROL.
PROVIDE RACEWAYS, WIRING, AND LAMPS (F40T8) FOR ALL LIGHT FIXTURESFURNISHED W/ THE FREEZER/COOLER/STORAGE UNIT. LIGHT FIXTURESSHALL BE INSTALLED BY ELECTRICAL CONTRACTOR. COORDINATE THEINSTALLATION OF SWITCHES AND PLATES WITH THE EQUIP. SUPPLIER.
J-BOX ON HOOD FOR PRE-WIRED HOOD LIGHTS.
G.C. TO VERIFY EXACT ELECTRICAL REQUIREMENTS FOR ILLUMINATEDSITE/MONUMENT SIGN STRUCTURE W/ SIGN SUPPLIER PRIOR TOINSTALLATION. G.C. TO PROVIDE FINAL ELECRICAL HOOK-UP.
36"x8"x8" SHEET METAL GUTTER FOR BALLAST AND CAPACITORS FORFIXTURES "H". MOUNT GUTTER ABOVE CEILING TO INTERIOR STUDS.
ROUTE CIRCUIT VIA EXTERIOR/SIGN LIGHTING CONTACTOR (SEE CONTROLSCHEMATIC DIAGRAM SHEET E100
FIXTURE TYPE "B1" EQUIPPED WITH EMERGENCY LIGHTING BATTERY PACK,THE BATTERY PACK SHALL BE WIRED AHEAD OF ANY SWITCHES.
CL
8
CL
8
A
c
A
c
A
c
A
bA
bA
b
A
bA
b
AA
b
A
b
A b
A
b
A
b
LL1
b
LL1
b
aLL4
2
bce3
d a
1
NOTE: NOT ALL NOTES MAY BE USED IN THIS PROJECT
INSTALLED AT 7'-0" AFF
INSTALLED AT 7'-6" AFF
S/S
EF-2EF-1
S/S S/S S/S S/S S/S S/S S/S
S/SS/SS/SS/SS/SS/SS/S
EF-3
S/S S/S S/S
S/S S/S S/S S/S S/S
S/SS/S
S
S
S
1 LIGHT FIXTURE SCHEDULEN.T.S.
7 LIGHTING PLAN1/4" = 1'-0"
17 DETAIL (PE CONTROL FOR FIXTURE 'WP')N.T.S. 9 LIGHTING CONTRACTOR DIAGRAM
N.T.S.
3 LIGHTING PLAN KEYNOTES
AFF
3. PROVIDE REMOTE MOUNTED (ON ROOF) PE CELL FOR ALL EXTERIOR FIXTURE, TYPE 'WP' NOT ON THE LIGHTING CONTACTOR.
2. ALL OUTLETS FOR LIGHTS SHALL BE SUPPORTED INDEPENDENTLY OF CEILING
4 LAMP ELECTRONIC BALLAST > 20% THD ELECTRONIC
SYSTEM USING 1/4 " ALL THREAD ROD.
1. SEE ARCHITECTURAL DETAILS FOR MOUNTING LOCATIONS.
CW20
FIXTURE NOTES:
PE
M
NOMENCLATURE
1/4 GEB
A12
COLD WEATHER BALLAST
FACTORY INSTALLED PHOTOCELL
METAL HALIDE SOURCE
PATTER #12 ACRYLIC PRISMATIC LENS
DEFINITIONS
5" x 7 GAUGE x 25' SQUARE STEEL POLE
(VERFIFY COUNTS AND TYPE WITH SITE PLAN)
VERIFY WIND LOAD TO ENSURE POLE SIZE IS SUFFICIENT.NOTE:
5
LL1
SITE LIGHTING
LL2
10 1000 WATT MH FLOODLIGHT
SECURITY
SECURITY
HERMITAGE
GOOSENECKS 100WMH - OUTDOOR
DESCRIPTION
EX
H
LED EXIT EMERGENCY COMBO
CL
MARK
A
QTY.
COOLER/FREEZER
2 x 4 LAY-IN LED
EXITRONIX
HILITE
CREE
MANUFACTURER
SSSP25-5-7-DBZ BRONZE
EDJ31111
ASBF000MH-DM-MT
PF346315721216
BRONZE MH1000/U/BT56
EVERGREEN
VEXUBPWHEL-90R
H811/C-EVG/38/LED2/40/F/BCM
BY COOLER MANUFACTURER
5F720CR244035
LIGHT FIXTURE
WHITE
COLOR
INCLUDED
44W
BULBS
LIGHT FIXTURE SCHEDULE
LABOR WARRANTY FOR TWO YEARS IS PROVIDED ON ALL PARKING LOT LIGHTING THRU HERMITAGE LIGHTING NATIONAL ACCOUNTS.
NO SUBSTITUTION ALLOWED FOR SPECIFIED LIGHT FIXTURES.
N/A
38W
LL4 6" RECESSED LED DOWNLIGHT
(7) 7W
LP
LP
D1
DBALCONY RECESSED SOFFIT LIGHT
SECURITY
SECURITY
851-DL-100MH-FP-WH-120
5F754FSL7 EVERGREEN
(1) MH100/U/MED
26.5W
7W
WHITE
WHITE
SHUTTER UPLIGHT / CUSTOM COLOR CASTROUND BOX COVER FOR FIXTURE
LL3 LED PENDANT HERMITAGE FLAVORIETY
ER
EM EMERGENCY LIGHTING UNIT
REMOTE EMERGENCY LIGHTING UNIT
(2) BLUE(3) AMBER(2) RED
WALL PACK w/ PHOTO CELL (REAR DOOR)WP 5F720EWP1X031 BRONZE 27WCREE
LED PENDANT
LED PENDANT HERMITAGE
C 12W6" RECESSED LED WALLWASHER WHITE
ALL LIGHT FIXTURES LISTED IN THE ABOVE SCHEDULE SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, EXCEPT AS NOTED INPARAGRAPH, PART 1.1.C OF ELECTRICAL SPECIFICATIONS.
PLEASE CONTACT HERMITAGE LIGHTING FOR INFORMATION ON LIGHTING PACKAGE, TEL. (800) 264-3383
(BY SIGN SUPPLIER/BALCONY)
4. BALLAST LOCATION FOR GOOSE NECKS INSTALLED PER N.E.C.
WHITE
CREE LE6GU24850-1000 LUMEN
RED
LL90
LL50H-N4EXITRONIX
EXITRONIX WHITE
WHITE (1) 5W
(2) 5W
E MANSARD WALL MOUNT UNIT PNKL10120SECURITY WHITE 11.3W
7W
12WCREE LR6GU24850-1000 LUMEN
DESIGNPARAMETERS, LLC
10495 S PROGRESS WAY #202PARKER, CO 80134PH: 303.668.1474FX: 303.223.9104
DESIGNPARAMETERS.COM
DIGITAL BOARD
42 x 28
42 x 28
42 x
28
42 x
28
42 x 28 42 x 28
42 x
28
42 x
28
22 x
28
22 x
28
22 x
28
22 x
28
56'' x 42''
TRASH
dig
ital b
oard
42" FLAT SCREEN
36" FLAT SCREEN
42" flat screen
42 x 28
5ft bu
lletin
boar
d
5-TI
ER
24"x
72"
5-TI
ER
24"x
60"
4-TIER
24"x36"
4-TIER
24"x42"
EF-2EF-1
FS-B FS-B
4-TIER
24"x48" 5-TIER
24"x60"
5-TIER
24"x60"
FREE STYLEDRINK MACH.
FREE
STY
LEDR
INK
MACH
.
FREE
STY
LEDR
INK
MACH
.
A-2H.D.
40"
H.D.40"
M
INTERLOCK W/ RTU-1
18"
TEL. OUTLET
A-18
24"
24"
120V / 1PH - TO RECP'TMOUNTED UNDER SINK
120V / 1PH - TO RECP'TMOUNTED UNDER SINK
18"
18"
A-20
A-20A-18
A-18
A-18
IG
C
C
IG
CHASE
CIGB-17
IG
C-1:3
C-5:7
C-9:11
C-6:8
C-39:41
C-10
C-2:4
C-18:20
C-17:19
C-34:36
C-29
B-17
B-17
18"
WP
SP
B-24
GFIWP
24"
WP 102"A-22
B-1378"
54"
48"
48"
48"
J
48"
WP
VERIFY LOCATION ON SITE PLAN
B-29
TO CENTERLINE OF OUTLET BOX. 102" DENOTES MOUNTING HEIGHTABOVE FINISHED GRADE/WALKWAY/PAVEMENT (TYPICAL-EXTERIOROF BLDG.)
B-22B-37
FOR DRIVE-THRUAUDIO SYSTEM SEEDETAIL 4 THIS SHEET
48" DENOTES MOUNTING HEIGHT ABOVE FINISHED FLOOR TOCENTERLINE OF OUTLET BOX. (TYPICAL-INTERIOR OF BLDG.)
B-22
A-23
76"
A-39:41
C-21:23
NEMA 6-30R
NEMA 5-30R
A-9
A-22
(TIE)C-16
102"WP
DP-8:10:12T
A-30
WP
FOR HEAT TRACE AT GREASERECOVERY
UNIT. (VERIFY EXACTLOCATION)
WP
48"
HTRWP/GFI
3-#10,1# 10GND-3/4" C
A-17
POWER CO METER & MAIN -SEE RISER DIAGRAM SHT E3
SERVICE SIGN & PUSHBUTTON
FOR HEAT TRACING IN THEFREEZER.
RUN 2 - 2" CONDUITS FROMTELEPHONE EQUIPMENT BOARD TOA LOCATION COORDINATED WITHLOCAL TELEPHONE COMPANY,OWNER REQUIREMENT SERVICECONDUITS SHALL BE SIZED FOR 25PAIR (MINIMUM). TELEPHONESERVICE CABLE, CONDUITS SHALLBE INSTALLED WITH PULLWIRE.CONDUITS RISE FROM U.G. INSIDEEXTERIOR WALL AND TURN-OUTWITH 90 DEG ELLS INSIDE BLDG. ATTERM. BD. SEE ARCHITECTURALELEVATIONS.OWNER REQUIRED SEPERATETELEPHONE SERVICE LINES TOBUILDING:(1) LINE FOR VOICE(1) LINE FOR SECURITY(1) LINE FOR CREDIT CARD(1) LINE FOR CASH REGISTER(1) LINE FOR COMPUTER LINES
A-15
BBUZZER
TC
A-14
24"
C-33
C-14
C-16
84"NEMA 15-30R
C-13:15
72"J60"
#10'S
FINISHED FLOOR
CEILING GRID
CABLE/S
@ 24
"A,F
,F,
SINGLE
TEL
DUAL/DOUBLE
TEL
DATAC
C
W/ 3/4" BUSHINGWIRELESS DRIVE-THRUCENTER MODULE(WALL MOUNTED)
CIRCUIT B-22120 VOLT DUPLEX
FIN. FLOOR
LOOP DETECTOR
P
SPEAKER POST.3/4" CONDUIT TO
VERIFY LOCATIONON SITE PLAN.
4"x4" J-BOX
COUNTER TOP
HOLE FOR SIGNALOUTLET BOX"
"PROVIDE STAINLESSSTEEL COVER PLATE
COORDINATE WITH SHEET K2.
SIGNAL 4"x4" J-BOX
18
17
16
15
11
14
13
12
9
10
8
7
6
5
4
2
3
1
19
20
21
22
1. ALL P.O.S. (POINT OF SALE) CIRCUITS SHALL HAVEAN ISOLATED GROUND WIRE BACK TO THE PANEL.ALL P.O.S. EQUIP. SHALL BE WIRED INDEPENDENTLYOF ANY NON-P.O.S. EQUIPMENT.
2. ALL RECEPTACLES FOR P.O.S. EQUIPMENT SHALL BEISOLATED GROUND WITH SURGE SUPPRESSORTYPE. ALL RECEPTACLES FOR P.O.S. EQUIPMENTSHALL BE SINGLE UNIT, UNLESS A DUPLEXRECEPTACLE CAN BE USED TO SUPPLY TWO P.O.S.UNITS. DUPLEX RECEPTACLES MAY BE USED IN THEMANAGER'S OFFICE FOR NON-P.O.S. EQUIPMENT(COMPUTER, MUSIC, FIRE ALARM, SECURITY, ETC.)
3. ALL CIRCUITS FOR P.O.S. EQUIPMENT SHALL BECONNECTED TO THE SAME PHASE OF POWER IN THEPANEL. ALL BRANCH CIRCUIT BREAKERSSUPPLYING P.O.S. EQUIPMENT SHALL HAVE LOCKINGHANDLES DEVICES.
4. EACH RECEPTACLE TYPE (LOCKING OR STRAIGHTBLADE) SHALL MATCH THAT OF THE EQUIPMENTFURNISHED. WHERE P.O.S. EQUIPMENT ISFURNISHED WITHOUT A PLUG THE RECEPTACLESHALL BE LOCKING TYPE. COORDINATERECEPTACLE TYPES WITH THE P.O.S. EQUIPMENTSUPPLIER.
GENERAL NOTES:
A. VERIFY MOUNTING HEIGHTSOF ALL RECEPTACLES WITHEQUIPMENT SUPPLIED PRIORTO INSTALLATION.
B. ALL EQUIPMENT ELECTRICALOUTLETS ARE DIMENSIONEDTO CENTERLINE OF BOXFROM ABOVE FINISHEDFLOOR.
C. ELECTRICAL CONTRACTORTO PROVIDE CORD & PLUGCONNECTIONS FOREQUIPMENT AS REQUIRED.
1" CONDUIT
REFER TO ARCHITECTURAL ELEVATIONS FOR EXACTDIMENSIONED LOCATIONS FOR ALL WALL OUTLETS
RECESSED SINGLE GANGELECTRICAL BOX.
1" OR 3/4" CONDUIT WITHPULL STRING AS NOTED.
CONDUIT BUSHING WITH TERMINATIONAT 6" ABOVE FINISHED CEILING.
SD
818
2
SD
RTU-3
SD
POWER PLAN KEY NOTES
NOTE: REFER TO OFFICE ELEVATION ON ARCHITECTURAL SHEETS
CEILING GRID
U.O.
N.
6'-0"
SPEAKERPOST
B-35
NOTE:ALL 15/20 AMPS RECEPTS WITH IN 6 FT.OF A SINK RIM OR IN AKITCHEN SHALL BE GFCI PROTECTED PER NEC 210.8 (B) (2) (5) (6)
GROUNDING NOTES :
A. PROVIDE GREEN INSULATED EQUIPMENT GROUNDINGCONDUCTORS IN ALL BRANCH CIRCUITS FOR CONNECTIONOF LOAD DEVICES TO THE POWER SOURCE GROUND.RACEWAYS SHALL NOT BE USED AS EQUIPMENTGROUNDING CONDUCTORS.
B. BOND CONDUITS, BOXES, AND ENCLOSURES TOGETHER,AND TO THE BUILDING GROUNDING SYSTEM.
17 DRIVE-THRU AUDIO / TIMERS
2 DRIVE-THRU LOOP DETECTOR
1 TYP. COMM. STUB UP DETAIL
3 ELECTRIC POWER PLAN & DETAILS1/4" = 1'-0"
9 POWER PLAN KEYNOTES
18 P.O.S NOTES
5 KITCHEN EQUIPMENT SCHEDULE
48"
60"
J
60"
KITCHEN EQUIPMENT SCHEDULE
A18.U6
A31
A47.4
A54
A92
B10
B60
B65
C10.27
C20
D20
D30
D70
D81
D90
D92
D93
D94
E10.1
E20.1
F15.1
H10.4PD
J40
K10
K31
K32
K42
K71
NOTES:1.
2.3.
4.5.6.
DESCRIPTION
FRYER BATTERY
MARINATOR
ICE BATTER
UPRIGHT FREEZER
GREASE COLLECTION SYSTEM
DOUBLE DECK OVEN
UPRIGHT REFRIGERATOR
BISCUIT HOLDING UNIT
SANDWICH PREP
VERTICAL TOASTER
MICROWAVE
PACKING STATION
HOT WATER DISPENSOR
CHUBB WARMER
HOLDING CABINET
HOLDING UNIT
CHICKEN HOLDING UNIT
HOLDING UNIT
WALK-IN COOLER
WALK-IN FREEZER
HOLDING UNIT
PRODUCTION COUNTER
U.C. REFRIGERATOR
ICE CUBER
SODA DISPSENSER
SODA DISPSENSER
BAG'N'BOX
TEA BREWER
Field verify device locations and mounting heights and equipment requirements with provider prior to rough-in. Field verify outlet, J-Boxor hardwire, number of wires, wire and circuit size requirements with provider prior to rough-in.Equipment numbers coordinate with Equipment Schedule on Architectural/Kitchen drawings, reference for additional information.All outlets serving equipment designated with NEMA 5-15 plugs shall be 20A duplex receptacles on a 20A branch circuit breaker in In accordance with NEC 210.21(B)(3) and shall be GFI per NEC 210.8(B).Notes 1-3 apply to all equipment.All raceways in millwork shall be run concealed from view.POS EQUIPMENT - Provide dedicated IG circuit with dedicated neutral and ground and data raceways - field verify requirements and additional scope of work with provider.
QTY.
3
1
1
1
1
2
1
1
1
1
2
1
2
1
1
2
1
2
1
1
1
1
1
2
1
2
1
1
LOAD
HP,KW,FLA8.5A
5A
2.3A
12A
10A
24A
12A
4.5A
6.5A
13A
20A
6A
19.2A
47.6A
17.6A
13.87A
25.7A
23.7A
12.7A
12.7A
18.8A
14A
4.9A
11.9A
1.5A
4A
7.2A
14A
VOLTS
120
120
120
120
120
208
120
120
120
120
208
208
208
208
120
208
208
208
208
208
208
120
120
208
120
120
120
120
Ø
1
1
1
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
3
3
1
1
1
1
1
1
1
1
BRANCH CKT.
CONDUCTORS2#12,#12G
2#12,#12G
2#12,#12G
2#12,#12G
2#12,#12G
4#10,#10G
2#12,#12G
2#12,#12G
2#12,#12G
2#12,#12G
3#10,#10G
3#12,#12G
3#12,#12G
3#4,#8G
2#12,#12G
3#12,#12G
3#8,#10G
3#10,#10G
3#10,#10G
3#10,#10G
3#10,#10G
2#12,#12G
2#12,#12G
3#12,#12G
2#12,#12G
2#12,#12G
2#12,#12G
2#12,#12G
COND.
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1-1/4"
3/4"
3/4"
1"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
CIRCUIT
C-33C-40A-5
A-19
A-15
C-16
DP-1,3,5DP-7,9,11
A-16
C-14
A-11
A-9
A-39,41C-21,23A-25,27
C-35,37C-30,32DP-4,6
A-23
C-17,19C-34,36
C-2,4
C-18,20
DP-14,16,18
DP-8,10,12
C-13,15
SEE PLANS
C-29
C-22,24C-26,28
B-13
B-35B-37A-7
B-11
RECEPT.5-20R
5-20R
5-20R
5-20R
5-20R
VERIFY
5-20R
5-20R
5-20R
5-20R
VERIFY
VERIFY
VERIFY
VERIFYVERIFYVERIFY
VERIFY
VERIFY
5-20R
VERIFY
5-20R
5-20R
5-20R
5-20R
November 17, 2014CONNECTION
DISC.
VERIFY
J-BOX
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
NOTES
A-18
DESIGNPARAMETERS, LLC
10495 S PROGRESS WAY #202PARKER, CO 80134PH: 303.668.1474FX: 303.223.9104
DESIGNPARAMETERS.COM
1 ELECTRICAL CONTRACTORS NOTES
NOTE:ELECTRICAL CONTRACTOR OR HVAC SHALL ORDER THE HVAC CONTROL PANEL BY CALLINGMARKETING AT NCA TOLL-FREE (877) 530-0078
NOTE:
THE CONTROL PANEL SHALL BE COMPLETE WHEN SHIPPED TO THE JOB SITE. NO INTERNAL WIRINGSHALL BE REQUIRED. MAKE ALL EXTERNAL WIRING CONNECTIONS AS REQUIRED.
"MORNING ARRIVAL"
STEP 1
TURN THE KITCHEN UN-OCCUPIED/OCCUPIED SWITCH TO THE THE OCCUPIED POSITION. THEKITCHEN AIR CONDITIONING SYSTEM WILL GO FROM NIGHT SETBACK MODE TO THE THERMOSTATSOCCUPIED SET POINT.
NOTE: THE KITCHEN AIR CONDITIONING BLOWER FANS WILL START AND RUN CONTINUOUSLY.THE EXHAUST FAN WILL NOT RUN UNTIL THE KITCHEN A/C SWITCH IS IN THE OCCUPIED POSITION.
STEP 2
TURN THE HOOD/EXH SWITCH TO THE ON POSITION THIS WILL TURN ON YOUR EXHAUST FAN ANDTHE COOKING EQUIPMENT UNDER THE HOOD.
"RESTAURANT OPEN FOR BUSINESS"
STEP 1
TURN THE DINING UN-OCCUPIED/OCCUPIED SWITCH TO THE THE OCCUPIED POSITION. THE DININGAIR CONDITIONING SYSTEM WILL GO FROM NIGHT SETBACK MODE TO THE THERMOSTATS OCCUPIEDSET POINT.
NOTE: THE DINING AIR CONDITIONING BLOWER FANS WILL START AND RUN CONTINUOUSLY."RESTAURANT CLOSE FOR BUSINESS"
STEP 1
TURN THE DINING UN-OCCUPIED/OCCUPIED SWITCH TO THE THE UNOCCUPIED POSITION. THEDINING AIR CONDITIONING SYSTEM WILL GO TO NIGHT SETBACK MODE.
STEP 2
TURN THE EXHAUST FAN SWITCH TO THE OFF POSITION.
"MANAGER/LAST PERSON LEAVING THE BUILDING"
STEP 1
TURN THE KITCHEN UN-OCCUPIED/OCCUPIED SWITCH TO THE UN-OCCUPIED POSITION. THEKITCHENS THERMOSTATS WILL SWITCH FROM THEIR OCCUPIED SETPOINTS TO THIER NIGHTSETBACKSETPOINTS.
PANEL LAYOUTCONTACTOR PANEL--18"wX30"hX6"d
CONTROL RISER DIAGRAM
PANEL SCHEMATIC DIAGRAMS
BLACK
WHITE
EXHAUST FAN 1&2C-1
FIRE INTERLOCK RELAYR-5
A1
A2
ANSUL FIRE INTERLOCK N.C. CONTACTS LOCATED AT HOOD
LOW VOLTAGE CONTROL WIRING
RS+5
RS1
18/8 LOW VOLTAGE
REMOTE SENSOR
RS GND
RS
RSV
COOLING 1 Y1
24 VOLT COMMON
HEATING 2
COOLING 2
HEATING 1
C
W2
W1
Y2
EVAP FAN
24V CONTROL
G
R
CONTROL CABLE W2
RS GND
R
C
G
W1
Y1
Y2
RTU T-STAT
ON - OFF PANEL
Y1
C
W2
W1
Y2
G
R
R1,2,3,4,5
R6,7
R1,2,3,4,5
CK1
CKGND
NEUTRAL WHITE
BROILER
R-4
A/C #4
BLACK
RED/GREEN
RED/
GREE
N
DINING OCC.SWITCH-2
KITCHEN OCC.SWITCH-1
HOOD/EXHSWITCH-3
BLACK
R-1
A/C #1
BLU
2A C.B.
FRYERMICRO SWITCH
FAN-1EXHAUSTFRYER
REMOTE SENSOR
REMOTE
SENSORREMOTE
SENSORREMOTE
SENSOR
AIR COND.
AIR COND. UNIT 2
UNIT 1
AIR COND. UNIT 3
SYSTEMANSUL
FRYER
&CONTACTOR
MOTORSTARTER
ENCLOSURE
CONTROL
R-5
FAN-2EXHAUST
A/C UNIT - 2
A/C UNIT - 1
FRONT DOOR CABLE
DP - 15
120 VOLT COILS
R-15 AMP
4-POLE5 AMP
4-POLE
R-2
4-POLE5 AMP
R-3 R-5
4-POLE5 AMP
A/C UNIT - 3
LINE 30A01020304
05
0607
30A
02 03 04
05 06 07
N NEUTRAL 1L1 PANEL- CIR- 2
A1 ANSUL (COM.) 3
A2 ANSUL (N.C.) 4
01 E-1 DAMPER02 E-1 DAMPER03 G EVAP. FAN04 Y-2 CLG-2
05 Y-1 CLG-1
06 W-2 HTG-2
07 W-1 HTG-108 R 24V POWER09 C 24V COMMON
10 RS+5 (RED WIRE)11 RS1 (BLK WIRE)12 RS GRN (GREEN WIRE)
REMOTE SENSOR
01 E-1 DAMPER02 E-1 DAMPER03 G EVAP. FAN04 Y-2 CLG-2
05 Y-1 CLG-1
06 W-2 HTG-2
07 W-1 HTG-108 R 24V POWER09 C 24V COMMON
10 RS+5 (RED WIRE)
11 RS1 (BLK WIRE)12 RS GRN (GREEN WIRE)
REMOTE SENSOR
01 E-1 DAMPER02 E-1 DAMPER03 G EVAP. FAN04 Y-2 CLG-2
05 Y-1 CLG-1
06 W-2 HTG-2
07 W-1 HTG-108 R 24V POWER09 C 24V COMMON
10 RS+5 (RED WIRE)11 RS1 (BLK WIRE)12 RS GRN (GREEN WIRE)
REMOTE SENSOR
UNIT - 2
71AUTO
MODE HUMIDITY
73
70
FAN OUTSIDE FILTER OVERIDERESET
UNIT - 1
71AUTO
MODE HUMIDITY
73
70
FAN OUTSIDE FILTER OVERIDERESET
CONTROLS2A
BREAKER
E1
E1
R-2
A/C #2
R1,2,3,4,5
VENSTART2700 THERMOSTAT
0808 R-3
A/C #3
UNIT - 4
71AUTO
MODE HUMIDITY
73
70
FAN OUTSIDE FILTER OVERIDERESET
UNIT - 3
71AUTO
MODE HUMIDITY
73
70
FAN OUTSIDE FILTER OVERIDERESET
A/C UNIT - 4
02 E-1 DAMPER03 G EVAP. FAN04 Y-2 CLG-2
05 Y-1 CLG-1
06 W-2 HTG-207 W-1 HTG-108 R 24V POWER09 C 24V COMMON
10 RS+5 (RED WIRE)
11 RS1 (BLK WIRE)12 RS GRN (GREEN WIRE)
REMOTE SENSOR
4-POLE5 AMP
R-4
91
C-1
EXH.#1,2
4 POLE CONTACTOR120V COIL 30A
C-2
FRYER
3 POLE CONTACTOR120V COIL 50A
4-POLE5 AMP
R-6
R-6
EF-2EF-2EF-1EF-1
PANEL- CIR- PANEL- CIR- PANEL- CIR- PANEL- CIR- PANEL- CIR- PANEL- CIR-
PANEL- CIR-
PANEL- CIR-
COOKING EQUIP.
COOKING EQUIP.
COOKING EQUIP.
COOKING EQUIP.
AIR COND. UNIT 4
EXH#1 TEMP SENSOR LINE 5EXH#1 TEMP SENSOR LOAD 6
EXH#2TEMP SENSOR LINE 7
EXH#2 TEMP SENSOR LOAD 8
5
6EXH#1 TEMP SENSOR
7
8EXH#2 TEMP SENSOR
NEM1 ENCLOSURE 18"w x 30"h x 6"d
BUILDING
OCCUPIEDUNOCCUPIED
SIGNAGE
OFF ONAUTO
LOT LIGHTS
OFF ONAUTO
N C A
START/STOP
EXHAUST/HOOD
ELECTRICAL CONTRACTOR NOTES:
1. RUN 0NE (10) CONDUCTOR 18 GAUGE THERMOSTAT CABLE FROM EACH ROOFTOP AIR CONDITIONINGUNIT TO THE CONTROL PANEL.
2. RUN 0NE (3) CONDUCTOR 18 GAUGE THERMOSTAT CABLE FROM THE CONTROL PANEL TO EACHREMOTE SENSOR LOCATION.
3. RUN 0NE (10) CONDUCTOR 18 GAUGE THERMOSTAT CABLE FROM EACH SMOKE DETECTOR TO THEATTENDANT AUDIO-VISUAL ANNUNCIATOR.
4. TERMINATION OF ALL 24 VOLT AIR CONDITIONING CONTROL WIRING SHALL BE DONE BY THEMECHANICAL CONTRACTOR.
5 LOW VOLTAGE CONTROL WIRING9 CONTROL RISER DIAGRAM
NOTE: T-STAT WIRING SHALL BE 18 AWG. 24V, 8 CONDUCTOR
6 PANEL SCHEMATIC DIAGRAMS
2 ELECTRICAL CONTRACTORS NOTES
10 PANEL LAYOUT12 PANEL ENCLOSURE
ON-OFF CONTROL PANEL WIRING
ONE AIR CONDITIONING SYSTEM SHOWN
RTU AIR/COND.
01
LOAD
DESIGNPARAMETERS, LLC
10495 S PROGRESS WAY #202PARKER, CO 80134PH: 303.668.1474FX: 303.223.9104
DESIGNPARAMETERS.COM
2 PANEL SCHEDULES
1 NEW 600 AMP SINGLE LINE DIAGRAM
ENCL.LC3
LC2
LC1
BREAKERNEMA 3R
3P600AMAIN
& S/N CTWP
LC3LC2 LC1
PE
METER
(2) RUNS EACH: 4 - #350 KCMIL, THWN, CU #1/0 CU GND IN (2) 3 1/2" CONDUITS.
4 - #4/0, THWN, CU # 4CU GND IN 2 1/2"
CONDUIT
H-O-A SELECTOR SWITCHES -CONTROLS FOR LTGCONTACTORS LOCATED AT SWSTATION NEAR OFFICE AREA.
4 - #4/0, THWN, CU # 4CU GND IN 2 1/2"
CONDUIT
TO EXTERIOR PARK'G LOTLTG. CIRCUITS
TO EXTERIOR LTG.CIRCUITS
REMOTE ROOF MOUNTEDPHOTO-ELEC-CONTROL SWITCH
(TYP.) FOR (2) SEE WIRINGDIAGRAM SHT. E1.
TERMINATE ON CONCRETE PADTRANFORMER PER POWER CO
REQUIREMENTS
PROVIDE & INSTALL CT CABINETAND METER IN ACCORD WITHPOWER CO REQUIREMENTS
ROUTE TWO RUNS : (4) 350 KCMIL, THWN, CU, IN(2) 3 1/2" CONDUITS VIA CT CABINET TO POWERCO SERVICE POINT AND TERMINATE AT SERVICELOC. PER POWER CO REQMT'S. REFER TO CIVIL SITEDWGS FOR LOCATION .
RUN #2/0 CONDUCTOR TO 5/8 " DIA. x 10'-0"LENGTH GROUNDING ROD. GROUNDING TOCONFORM TO SECTION 250-50 (N.E.C.)
METAL WATER PIPEWHERE AVAILBLESTEEL REBARS IN
FOUNDATION
LISTED FORAVAILABLE FAULT
CURRENT
ENGRAVED SIGN "MAINDISCONNECT"
IDENTIFICATION PLAQUE
THESE ITEMS ONLYWHEN REQUIRED BY
LOCAL CODES
TO EXTERIOR SIGNCIRCUITS
PANEL"C"
PANEL"A"
PANEL"B"
PANEL "DP"600A M.C.B
I-LINE
9 FAULT CURRENT CALC'S.
F1
F2
F3F4
SUMMARY LOAD CALCULATIONS (SES) BUILDING
SES = 600 AMPPANEL "DP" ----------------------------------------------------- = 476 AMP
TOTAL SES LOAD AMPS = 476 AMPS < 600 AMPS
THESE SERVICES CAN BE SERIES RATED SYSTEM TWO-TIER (65/22K).
THE CONTRACTOR SHALL LABEL "SES":"CAUTION" SERIES RATED SYSTEM (65/22K). 65,000 A AVAILABLE IDENTIFIED REPLACEMENT COMPONENT REQUIRED" IN ACCORDANCE WITH NEC 110-22.
THE CONTRACTOR SHALL LABEL:PANEL 'DP': "CAUTION" SERIES RATED SYSTEM (65/22K). 60,367 AMPS
....AVAILABLE IDENTIFIED REPLACEMENT COMPONENT REQUIRED." IN ACCORDANCE WITH NEC 110-22 AND NEC 240-86(a).THE MOTOR CONTRIBUTION TO THE FAULT CURRENT MEETS THE 1% CRITERIA STATED IN ACCORDANCE WITH NEC 240-86(b) FOR SERIES RATED SYSTEMS.NO DESIGN CHANGES MAY BE MADE TO THE SYSTEM WITHOUT THE PRIOR APPROVAL OF THE DESIGN ELECTRICAL ENGINEER AND THE ELECTRICALINSPECTOR.
PANEL SCHEDULE: PROJECT:LOCATION:JOB NO.:COMMENTS: BUS RATING:MAIN O.C. DEVICE:MOUNTING: CIR
NO.
13579
11131517192123252729313335373941
NOTES:
1.
CIRCUIT
AMPS
202020202020
20202020252020202020
2020
CONNECTED LOAD:
Popeye'sBack of Space2014-135New Panelboard
BREAKER
POLE
111111
1111122111
22
PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL LOAD (VA):
225AM.L.O.Flush Mounted
CONNECTED
LOAD (VA)
1320 1320 600
1728 1500 780
1440 1600 376
2110 720 720
1180
2000 2000
10,124 11,528 12,840 34,492
A
NEC DEMAND
FACTOR
1.00 1.00 0.65 0.65 0.65 0.65
0.65 0.65 0.65
0.65 0.65 0.65
0.65
0.65 0.65
DESCRIPTION OF
LOAD SERVED
EF-1EF-2
A31 MarinatorK42 Carbonator
C20 ToasterC10.27 Sandwich
Bussed SpaceA54 Freezer
E10 Freezer EvapA47.4 Refrig. Battery
SpareD90 Holding CabinetD30 Packing StationD30 Packing Station
SpareE10 Cooler Evap
SpareBussed SpaceBussed Space
D20 MicrowaveD20 Microwave
PHASE
ABCABCABCABCABCABCABC
VOLTAGE L-L:VOLTAGE L-G:SYSTEM: S.C.RMS RATING:
DESCRIPTION OF
LOAD SERVED
EF-3Hood ControlsReceptOffice Cab. FanService DoorbellIrrigation ControlsAnsul SystemB60 RefrigeratorDining Room ReceptDining Room ReceptSecurity CameraWater HeaterCooler/Freezer ltsE10 Cooler EvapE10 Heat Trace FreezerSite LightsSite LightsSite LightsSite LightsSite LightsSite Lights
DEMAND LOAD:PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL DEMAND LOAD (VA):
2081203Ø, 4-WIRE
22,000 AIC
NEC DEMAND
FACTOR
1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.65 1.00 1.00 1.00 1.00 1.00 0.65 0.65 1.25 1.25 1.25 1.25 1.25 1.25
9,313 9,721 10,599 29,632
CONNECTED
LOAD (VA)
600 300
1150 100 100 600 540 684 540 900 600 100 300 504
1000 1180 1180 1180 1180 1180 1180
82.25
November 17, 2014
CIRCUIT
POLE
111111111111111222222
A
BREAKER
AMPS
202020202020202020202020202020303030303030
CIR
NO.
2468
1012141618202224262830323436384042
PANEL SCHEDULE: PROJECT:LOCATION:JOB NO.:COMMENTS: BUS RATING:MAIN O.C. DEVICE:MOUNTING: CIR
NO.
1357911131517192123252729313335373941
NOTES:
1.
CIRCUIT
AMPS
303030303030505050
225225225225225225225225225
CONNECTED LOAD:
Popeye'sBack of Space2014-135New Panelboard
BREAKER
POLE
333333333333333333
PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL LOAD (VA):
600A600A M.C.B.Flush Mounted
CONNECTED
LOAD (VA)
2880 2880 2880 2880 2880 2880
9313 9721 10599 10529 7780 10734 17066 14922 16973
58,824 59,089 64,972 182,885
DP
NEC DEMAND
FACTOR
0.65 0.65 0.65 0.65 0.65 0.65
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
DESCRIPTION OF
LOAD SERVED
B10 Conv. OvenB10 Conv. OvenB10 Conv. OvenB10 Conv. OvenB10 Conv. OvenB10 Conv. Oven
SpareSpareSpare
Panel 'A'Panel 'A'Panel 'A'Panel 'B'Panel 'B'Panel 'B'Panel 'C'Panel 'C'Panel 'C'
Bussed SpaceBussed SpaceBussed Space
PHASE
ABCABCABCABCABCABCABC
VOLTAGE L-L:VOLTAGE L-G:SYSTEM: S.C.RMS RATING:
DESCRIPTION OF
LOAD SERVED
Bussed SpaceD81 Chub WarmerD81 Chub WarmerWalk-In FreezerWalk-In FreezerWalk-In FreezerWalk-In CoolerWalk-In CoolerWalk-In CoolerRTU-2RTU-2RTU-2RTU-1RTU-1RTU-1RTU-3RTU-3RTU-3Walk-In CoolerWalk-In CoolerWalk-In Cooler
DEMAND LOAD:PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL DEMAND LOAD (VA):
2081203Ø, 4-WIRE
22,000 AIC
NEC DEMAND
FACTOR
0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
56,361 54,964 60,847 172,172
CONNECTED
LOAD (VA)
4750 4750 652 652 652 624 624 624
4445 4445 4445 4445 4445 4445 5366 5366 5366 624 624 624
477.92
November 17, 2014
CIRCUIT
POLE
22333333333333333333
A
BREAKER
AMPS
6060303030303030606060606060606060303030
CIR
NO.
2468
1012141618202224262830323436384042
PANEL SCHEDULE: PROJECT:LOCATION:JOB NO.:COMMENTS: BUS RATING:MAIN O.C. DEVICE:MOUNTING: CIR
NO.
1357911131517192123252729313335373941
NOTES:
1.
CIRCUIT
AMPS
20202020202020202020202020202020202020
CONNECTED LOAD:
Popeye'sBack of Space2014-135New Panelboard
BREAKER
POLE
1111111111111111111
PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL LOAD (VA):
225AM.L.O.Flush Mounted
CONNECTED
LOAD (VA)
360 1000 1264 1380 600 1920 600 390 720 1200 1200 1420 360 540 720 600
480 480
10,529 7,780 10,734 29,043
B
NEC DEMAND
FACTOR
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
1.00 1.00
DESCRIPTION OF
LOAD SERVED
RTU Recept & Duct Det.Digital Menu Board
Kitchen & Sales LightingKitchen & RR. Lighting
Dining Pad FansK71 Tea Brewer
K31 Soda DispenserFront Sign
Video MonitorsMonument SignMonument Sign
Fly FanSecurity System
POS SystemRecs-GP (Front Counter)
M30 SafeSpare
K32 Soda DispenserK32 Soda Dispenser
Bussed SpaceBussed Space
PHASE
ABCABCABCABCABCABCABC
VOLTAGE L-L:VOLTAGE L-G:SYSTEM: S.C.RMS RATING:
DESCRIPTION OF
LOAD SERVED
Dining LightsDining Pendant LightsTTBOffice ReceptMusic SystemComputer/PrinterD/T WindowDrive Thru Dir. SignsDrive Thru MenuLighting ControlsDrive Thru AudioPOS System/PrinterSpareExterior Soffit LightsExterior Soffit LightsExterior Soffit LightsDigital Menu SystemDigital Pre-Sell M/BWall Art LightsBussed SpacePOS System/Printer
DEMAND LOAD:PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL DEMAND LOAD (VA):
2081203Ø, 4-WIRE
22,000 AIC
NEC DEMAND
FACTOR
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
1.00 1.00 1.00 1.00 1.00 1.00
1.00
10,529 7,780 10,734 29,043
CONNECTED
LOAD (VA)
1384 700 360 360 500 500
1800 360 500 100
1200 600
790 790
1125 500 500 780
960
80.62
November 17, 2014
CIRCUIT
POLE
1111111111111111111
1
A
BREAKER
AMPS
20202020202020202020202020202020202020
20
CIR
NO.
2468
1012141618202224262830323436384042
PANEL SCHEDULE: PROJECT:LOCATION:JOB NO.:COMMENTS: BUS RATING:MAIN O.C. DEVICE:MOUNTING: CIR
NO.
13579
11131517192123252729313335373941
NOTES:
1.
CIRCUIT
AMPS
202030303030303030303030202020
2020202020
CONNECTED LOAD:
Popeye'sBack of Space2014-135New Panelboard
BREAKER
POLE
222222222222111
12222
PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL LOAD (VA):
225AM.L.O.Flush Mounted
CONNECTED
LOAD (VA)
1456 1456 2578 2578 2578 2578 1950 1950 1250 1250 2000 2000 1920
588
2040 2000 2000 437 437
25,222 22,957 25,079 73,258
C
NEC DEMAND
FACTOR
0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 1.00
0.65
0.65 0.65 0.65 0.65 0.65
DESCRIPTION OF
LOAD SERVED
HD10.4PD Prod. Count.HD10.4PD Prod. Count.HD10.4PD Heat LampsHD10.4PD Heat LampsHD10.4PD Heat LampsHD10.4PD Heat Lamps
F15.1 Holding UnitF15.1 Holding Unit
D92 Holding BinD92 Holding BinD20 MicrowaveD20 Microwave
Hand DryerSpare
J40 UC RefrigeratorShunt Trip
A18.U6 Fryer/TimerD70 Hot Water Disp.D70 Hot Water Disp.
HD10.4PD Heat LampsHD10.4PD Heat Lamps
PHASE
ABCABCABCABCABCABCABC
VOLTAGE L-L:VOLTAGE L-G:SYSTEM: S.C.RMS RATING:
DESCRIPTION OF
LOAD SERVED
D93 Holding BinD93 Holding BinH10.4PD Immers. HeatH10.4PD Immers. HeatH10.4PD LightingA92 Grease Coll. SysB65 Bisuit HoldA92 Heat Trace BossD94 Holding CabinetD94 Holding CabinetK10 Ice CuberK10 Ice CuberK10 Ice CuberK10 Ice CuberD70 Hot Water Disp.D70 Hot Water Disp.D92 Holding BinD92 Holding BinShunt TripA18.U6 Fryer/TimerHand Dryer
DEMAND LOAD:PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL DEMAND LOAD (VA):
2081203Ø, 4-WIRE
22,000 AIC
NEC DEMAND
FACTOR
0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65
0.65 1.00
17,066 14,922 16,973 48,962
CONNECTED
LOAD (VA)
4250 4250 3000 3000 1920 1200 540
1200 2850 2850 1428 1428 1428 1428 2000 2000 1250 1250
1020 1920
135.91
November 17, 2014
CIRCUIT
POLE
221111112222221111
11
A
BREAKER
AMPS
404020202020202030302020202020202020
2020
CIR
NO.
2468
1012141618202224262830323436384042
FAULT CURRENT CALCULATION TABLE
NOTES:1.2.
3.4.5.
6.
LOCATION (n)300
600A MainPanel DPPanel APanel BPanel C
All Calculations use Bussman "Point-To-Point" Method.Variables:
The E.C. shall report any discrepancies to the Engineer.Aluminum Conductors, MC Cabling, and Series Rated Panels are not allowed.The E.C. shall verify the Available Fault Current from the Electrical Utility and shall report theactual Fault Current available to the Engineer if different from shown. Fault Currents are basedon Utility information or %Z=1.4 if none are provided.The E.C. shall field verify the Feeder Lengths and report any discrepancy to the engineer.Conductor Lengths listed in this table are engineering estimates and are not intended to representactual lengths for bidding or other calculations. The E.C. shall inform the Engineer immediatelyif the actual lengths are less than that listed.
# of RUNSUtility Transformer
22111
L=Feeder Length (LF)f(n) = (1.73 x L x F(n-1))/(C x # of runs x Voltage) in Amperes
CONDUCTOR
3503504/04/04/0
VOLTAGE208208208208208208
C=Conductor "C" Value
L(ft)
10015101010
C
22,73719,70415,08215,08215,082
f
0.950.080.140.140.14
November 17, 2014
M
0.510.920.880.880.88
M(n) =1 ÷ (1+f(n))F(n)=F(n-1) x M(n)
F 52,00026,65224,57821,64421,64421,644
DESIGNPARAMETERS, LLC
10495 S PROGRESS WAY #202PARKER, CO 80134PH: 303.668.1474FX: 303.223.9104
DESIGNPARAMETERS.COM
1 MONITOR BRACKET1'-1/2" = 1'-0"
A.F.F.EL. 9'-4"
6'-8
"
REGISTER CONNECTIONS
1. CABLES SHALL BE COAX.
2. BUMP BARS SHALL BE MOUNTED TO DELIVERY SYSTEM AT AREASMARKED "BB".
3. BUMP BAR CABLES SHALL BE RUN THROUGH DELIVERY SYSTEMFROM MOUNT UP THROUGH WALLS TO ABOVE THE CEILING ANDBACK TO THE MANAGER STATION.
4. CRT MONITORS SHALL BE MOUNTED ON CEILING BRACKETSPROVIDED BY REGISTER SYSTEM.
5. WHERE CABLING IS INSTALLED IN WALLS, IT SHALL BE ROUTED INA 1" CONDUIT THROUGH WALL TO ABOVE ACCESSIBLE CEILING.
BUMP BAR WIRING
VIDEO MONITOR AND POS WIRING
SECURITY WIRING
BB - BUMP BARS
V1 = VIDEO 1V2 = VIDEO 2V3 = VIDEO 3
POS- POINT OF SALE TERMINAL
CRT
DINING
REFERENCE ONLYCOORDINATE WITH P.O.S.SUPPLIER
BB
ABOVE
V3
V1
POS
POS
POS
V2
CEILING
OFFICE
DRIVE THRU
PREP
SERVICE SALES
NOTES:1. MONITOR BRACKETS TO BE SUPPLIED AND INSTALLED BY P.O.S.
VENDOR.2. G.C. TO SUPPLY 2x4 BLOCKING AND TO SECURE BLOCKING AT
LOCATION PER P.O.S. VENDOR DIRECTION. VERIFY W/ P.O.S.VENDOR BEFORE INSTALLATION
(2) 1/2"U-BOLTS
DBL. 2X4 BLOCKING W/ SIMPSON "U"HANGERS @ EA. END TO TO ROOFTRUSSES OR JOISTS TOG.C.
RAFTER PLATE
INNER STEEL CHANNEL
CEILING TILE
FLASHING PLATE
OUTER STEEL CHANNEL
ATTACH MONITOR BRACKET W/ (2)1/4" BOLTS
WHT. PLASTIC SLEEVE TO CONCEALCHANNELS & POWER CORDS (NOT SHOWN)
S.S. STEELMONITORBRACKET
MONITORASSEMBLY
BRACKETCOVER BY
P.O.S.VENDOR
POS
5 LEGEND9 REGISTER CONNECTIONS
6 POS PLAN1/4" = 1'-0"
LEGEND
COORDINATE DSL CONNECTION
DESIGNPARAMETERS, LLC
10495 S PROGRESS WAY #202PARKER, CO 80134PH: 303.668.1474FX: 303.223.9104
DESIGNPARAMETERS.COM
DIGITAL BOARD
42 x 28
42 x 28
42 x
28
42 x
28
42 x 28 42 x 28
42 x
28
42 x
28
22 x
28
22 x
28
22 x
28
22 x
28
56'' x 42''
TRASH
dig
ital b
oard
42" FLAT SCREEN
36" FLAT SCREEN
42" flat screen
42 x 28
5ft bu
lletin
boar
d
5-TI
ER
24"x
72"
5-TI
ER
24"x
60"
4-TIER
24"x36"
4-TIER
24"x42"
EF-2EF-1
FS-B FS-B
4-TIER
24"x48" 5-TIER
24"x60"
5-TIER
24"x60"
FREE STYLEDRINK MACH.
FREE
STY
LEDR
INK
MACH
.
FREE
STY
LEDR
INK
MACH
.
SL
CPM14"
DVR
OFFICE
GB
DINING
GB
SERVICE
D
B-3
DRV-THRU
B-2
D
HOLD UP BUTTON 5
STROBE LIGHT
Dome
IEI KEYPAD
14" Monitor
EXTERIOR DOME CAMERA
GLASS BREAK
DOOR CONTACT
CONTROL PANEL
HORN/SOUNDER
MOTION DETECTOR(CEILING MOUNT)
KEY PAD
GB
KP
M
CP
C
SN
2
1
1
1
5
1
DIGITAL VIDEO RECORDER
SYMBOL QTY.
M
DVR
SL 1
1
3
14"
D
1
1
5
SN
PIEZO 1
P
P
B-4
D
POS
POS
SAFE
POS
POS
IEI
M
B-6D
POPEYES INSTALLATION NOTESNOTE: PROGRAMMING SEQUENCE SET-UP AT THE NCCC
FOR LOCATIONS WITH OUTDOOR CAMERASOUTDOOR POLE MOUNT 15' ABOVE FINISHED PAVEMENTGROUND ISOLATION TRANSFORMERS
SECURITY CO. TO RUN FLEX CONDUIT INSIDE LIGHT POLES- EC TO RUN CONDUITFFROM RESTAURANT TO BASE OF LIGHT POLE & MOUNT JUNCTION BOX 15'ABOVE FINISHED PAVEMENT ON POLE VIEW DRIVE-UP AND SIDE DOOR
A -1 : VIEW BACK DOOR, MENU BOARD & REAR AREAA-2 : VIEW SIDE DOOR AREA OPPOSITE SIDE OF BUILDING FROM DRIVE-THRU
INDOOR CAMERASINDOOR CEILING MOUNT IN TINTED DOMEFASTEN SCREW IN CEILING FOR DOMES SO NOT EASILY DROPPED OUT OF TILE
B-1 : VIEW FRONT DOORS, RESTROOM AREA & SALES COUNTERB-2 : VIEW DRIVE-THRU REGISTER & WINDOW AREAB-3 : VIEW SALES COUNTER & SAFE AREAB-4 : VIEW BACK DOOR & COOLER/FREEZER AREA
OFFICE AREABAC- BURGLAR ALARM CONTROL-VISTA 20SEUL
D-VCRE-VCR :F-MONITOR :
QUICK REFERENCE SHEETS
ALARM INSTRUCTION SHEET TO BE MOUNTED ON WALL IN EMPLOYEE ONLY AREACLOSEST TO KEYPAD OR IN OFFICE AREA PER CUSTOMER INSTRUCTION
FOR LOCATIONS WITH 6 OR MORE CAMERAS: ADD MULTIPLEXERLTC 2641/60-PLACE ON SECURITY LOCK FOR NO TAMPER
FOR LOCATIONS WITH 4 CAMERAS OR LESS:ADD VIDQUAD 4 CHANNEL LTC 2272/60
HUB: HOLD UP BUTTON 441494 SERIES LATCHING HUB
MANAGER AREA-36" AFF OUT OF SITE FROM FRONT COUNTER
DRIVE-THRU WINDOW-18" AFF & OUT OF SITE FROM OUTSIDE
FRYER/PREP AREA
SL: STROBE LIGHT - AS SL-401B-BLUE STROBE MOUNT BEHIND MENU BOARD, ITWILL FLASH CONTINUOUSLY WHILE BACK DOOR IS OPEN
S: SOUNDER-AS-PAL328N-LOW TONE SOUNDER MOUNT WITH STROBE BEHINDMENU BOARD, IT WILL SOUND WHEN BACK DOOR IS OPENED, MANAGER WILLSILENCE ST SOUNDER AT KEYPAD AFTER 1 TONE
MD: MOTION DETECTOR-AP 669 PIR-360 MOTION MOUNT IN STOVE AREA TO GETAREA FROM DRIVE-UP WINDOW AND GENERAL REAR AREA
LOBBY/PERIMETER AREA/BACK OF HOUSE
KP: KEY PAD-MOUNT 40" AFF WALL ENTERING KITCHEN AREA FROM LOBBY
GB: FG 1025 GLASS BREAK-LOBBY GLASS ONE EACH SIDE OF BUILDING SEEDRAWING FOR DEVICE PLACEMENT
C: B4039 CONTACT-ALL EXTERIOR DOORS
BACK DOOR CONTACT TO ACT AS ALARM POINT FOR BACK DOOR ALARM-24 HOURLOCATION POINT-SOUNDER & BLUE STROBE TO ACTIVATE WHEN BACK DOOR ISOPEN
HUB: 3050CT SERIES LATCHING HUB IN COOLER/FREEZER-MOUNT 18" AFF ONHINGE SIDE OF DOOR, STUB UP CONDUIT TO PROTECT WIRING FROMCONDENSATION/DAMAGE NO DRIP LOOP AT HUB
POC : POINT OF CONNECTION TO NKL SAFE-PIGTAIL PROVIDED BY NKL SAFE
POPEYES ADD ON MODIFICATION NAMES AND PHONE NUMBERS
1. INSTALLER PLEASE CONTACT YOUR ADT NCCC PROJECT COORDINATOR FORANY ADD-ONS OR MODIFICATIONS TO YOUR JOB. THEY WILL CONTACT THENATIONAL ACCOUNT MANAGER FOR APPROVALS/PAPERWORK.
2. CONTACT THE NATIONAL ACCOUNT MANAGER.
POPEYES PROBLEM RESOLUTION NAMES & PHONE NUMBERS
ACKERMAN / LOCKNET:
NCCC PROJECT COORDINATOR:NAME:PHONE NUMBER:
NATIONAL ACCOUNT MANAGER:
AFC/POPEYES:
NEW INSTALLS/NEW CONSTRUCTION MANAGER
EXISTING SITES/RENOVATION PROJECTS/FACILITIES MANAGER
LOSS PREVENTION DIRECTOR:
POPEYES INSTALLATION ACCEPTANCE FORM/CHECKLIST
FOR INSTALL SITE MODIFICATIONS IE/DEVICE PLACEMENT CHANGES FROM BLUEPRINT,HAVE CUSTOMER INITIAL MODIFY PER SITE OPTION TO SHOW APPROVAL
CAMERAS
A-CAMERA : FOR LOCATIONS WITH OUTDOOR CAMERAS
OUTDOOR POLE MOUNT 15' ABOVE FINISHED PAVEMENT
YES_____________ N/A______________ MODIFY PER SITE__________
GROUND ISOLATION TRANSFORMERS
YES_____________ N/A______________ MODIFY PER SITE__________
ADT TO RUN CONDUIT INSIDE LIGHT POLES-EC TO RUN CONDUIT FROM RESTAURANT TOBASE OF LIGHT POLE & MOUNT JUNCTION BOX 15' ABOVE FINISHED PAVEMENT ON POLE
YES_____________ N/A______________ MODIFY PER SITE__________
A-1; VIEW DRIVE-UP AND SIDE DOOR
YES_____________ N/A______________ MODIFY PER SITE__________
A-2: VIEW BACK DOOR, MENU BOARD & REAR AREA
YES_____________ N/A______________ MODIFY PER SITE__________
A-3: VIEW SIDE DOOR AREA OPPOSITE SIDE OF BUILDING FROM DRIVE-THRU
YES_____________ N/A______________ MODIFY PER SITE__________
B-CAMERA: FOR LOCATIONS WITH INDOOR CAMERAS INDOOR CEILING MOUNT IN TINTEDDOME
YES_____________ N/A______________ MODIFY PER SITE__________
FASTEN SCREW IN CEILING FOR DOMES SO NOT EASILY DROPPED OUT OF TILE
YES_____________ N/A______________ MODIFY PER SITE__________
B-1: VIEW FRONT DOORS, RESTROOM AREA & SALES COUNTER
YES_____________ N/A______________ MODIFY PER SITE__________
B-2: VIEW DRIVE-THRU REGISTER & WINDOW AREA
YES_____________ N/A______________ MODIFY PER SITE__________
B-3: VIEW SALES COUNTER & SAFE AREA
YES_____________ N/A______________ MODIFY PER SITE__________
B-4: VIEW BACK DOOR & COOLER/FREEZER AREA
YES_____________ N/A______________ MODIFY PER SITE__________
B-5: 360 VIEW
YES_____________ N/A______________ MODIFY PER SITE__________
OFFICE AREA
D-VCR LOCK BOX: TC3922 SERIES
YES_____________ N/A______________ MODIFY PER SITE__________
E-VCR: LTC 3924 SERIES PLACE ON SECURITY LOCK FOR NO TAMPER
YES_____________ N/A______________ MODIFY PER SITE__________
QUICK REFERENCE SHEETS
ALARM INSTRUCTION SHEET TO BE MOUNTED ON WALL IN EMPLOYEE ONLY AREACLOSEST TO KEYPAD OR IN OFFICE AREA PER CUSTOMER INSTRUCTION
YES_____________ N/A______________ MODIFY PER SITE__________
VCR INSTRUCTION SHEET( 2) 1-REVIEW & 1-RECORD-TO BE MOUNTED ON WALLCLOSEST TO VCR
YES_____________ N/A______________ MODIFY PER SITE__________
FOR LOCATIONS WITH 6 OR MORE CAMERAS: ADD MULTIPLEXER
LTC 2641/60-PLACE ON SECURITY LOCK FOR NO TAMPER
YES_____________ N/A______________ MODIFY PER SITE__________
FOR LOCATIONS WITH 4 CAMERAS OR LESS:
ADD VIDQUAD 4 CHANNEL LTC 2272/60
YES_____________ N/A______________ MODIFY PER SITE__________
HUB: HOLD UP BUTTON 441494 SERIES LATCHING HUB
MANAGER AREA-36" AFF OUT OF SITE FROM FRONT COUNTER
YES_____________ N/A______________ MODIFY PER SITE__________
DRIVE-THRU WINDOW-18" AFF & OUT OF SITE FROM OUTSIDE
YES_____________ N/A______________ MODIFY PER SITE__________
LOBBY/PERIMETER AREA/BACK OF HOUSE
KP: KEYPAD-MOUNT 40" AFF WALL ENTERING KITCHEN AREA FROM LOBBY
YES_____________ N/A______________ MODIFY PER SITE__________
GB: FG 1025 GLASS BREAK- LOBBY GLASS ONE EACH SIDE OF BUILDING SEEDRAWING FOR DEVICE PLACEMENT
YES_____________ N/A______________ MODIFY PER SITE__________
C: B4039 CONTACT-ALL EXTERIOR DOORS
YES_____________ N/A______________ MODIFY PER SITE__________
BACK DOOR CONTACT TO ACT AS ALARM POINT FOR BACK DOOR ALARM-24 HOURLOCATION POINT-SOUNDER & BLUE STROBE TO ACTIVATE WHEN BACK DOOR IS OPEN
YES_____________ N/A______________ MODIFY PER SITE__________
YES_____________ N/A______________ MODIFY PER SITE__________
POC: POINT OF CONNECTION TO NKL SAFE-PIGTAIL PROVIDED BY NKL SAFE
YES_____________ N/A______________ MODIFY PER SITE__________
FRYER/PREP AREA
SL: STROBE LIGHT-AS SL-401B-BLUE STROBE MOUNT BEHIND MENU BOARD, IT WILLFLASH CONTINUOUSLY WHILE BACK DOOR IS OPEN
YES_____________ N/A______________ MODIFY PER SITE__________
S: SOUNDER-AS-PAL328N-LOW TONE SOUNDER MOUNT WITH STROBE BEHIND MENUBOARD, IT WILL SOUND WHEN BACK DOOR IS OPENED, MANAGER WILL TONESILENCE SOUNDER AT KEYPAD AFTER 1
YES_____________ N/A______________ MODIFY PER SITE__________
MD: MOTION DETECTOR-AP 669 PIR - 360 MOTION MOUNT IN STOVE AREA TO GET AREFROM DRIVE-UP WINDOW AND GENERAL REAR AREA
YES_____________ N/A______________ MODIFY PER SITE__________
POPEYES MATERIAL LIST
CAMERASA-CAMERA:6 OR 7 LOCATIONS ( LOCATIONS W/OUTDOOR CAMERAS )2 OR 3 GIT100-GROUND ISOLATION TRANSFORMERSLTC 0430/20-38 SERIES CAMERA W/ 3.5-8MM VARIFOCAL AUTOIRIS LENSTC 9340A SERIES OUTDOOR HOUSINGTC9211PM POLE MOUNT ADAPTERBNC CONNECTORS FOR PLENUM CABLEFLEX CONDUIT FOR OUTDOOR CAMERAS RUN INSIDE POLE FOR CABLING
INDOOR CEILING MOUNT IN TINTED DOMENOTE: FASTEN SCREW IN CEILING FOR DOMES SO NOT EASILY DROPPED OUT OF TILE LTC 0430/20-38SERIES CAMERA W/ 3.5MM-8MM VARIFOCAL AUTOIRIS LENSTC 9345MT7 INDOOR TINTED DOMEBNC CONNECTORS FOR PLENUM CABLE
OFFICE AREABAC-BURGLAR ALARM CONTROL: VISTA 20SEULD-VCR LOCK BOX : TC3922 SERIESE-VCR: LTC 3924 SERIES PLACE ON SECURITY LOCK FOR NO TAMPERF-MONITOR: LTC 2813/60 SERIESALTV248: 8 POSITION POWER SUPPLYQUICK REFERENCE SHEETSALARM INSTRUCTION SHEET TO BE MOUNTED ON WALL IN EMPLOYEE ONLY AREA CLOSEST TO KEYPADOR IN OFFICE AREA PER CUSTOMER INSTRUCTIONVCR INSTRUCTION SHEETS (2) 1-REVIEW & 1-RECORD-TO BE MOUNTED ON WALL CLOSEST TO VCR
FOR LOCATIONS WITH 6 OR MORE CAMERAS : ADD MULTIPLEXER LTC 2641/60-PLACE ON SECURITY LOCKFOR NO TAMPER
FOR LOCATIONS WITH 4 CAMERAS OR LESS : ADD VIDQUAD 4 CHANNEL LTC 2272/60
2-HUB: HOLD UP BUTTON 441494 SERIES LATCHING HUB
STOVE/PREP AREA
SL: STROBE LIGHT-AS SL-401B-BLUE STROBE MOUNT BEHIND MENU BOARD, IT WILL FLASHCONTINUOUSLY WHILE BACK DOOR IS OPEN
S: SOUNDER-AS-PAL328N-LOW TONE SOUNDER MOUNT WITH STROBE BEHIND MENU BOARD, IT WILLSOUND WHEN BACK DOOR IS OPENED, MANAGER WILL SILENCE ST SOUNDER AT KEYPAD AFTER 1STTONE
MD; MOTION DETECTOR-AP 669 PIR-360 MOTION MOUNT IN STOVE AREA TO GET AREA FROM DRIVE-UPWINDOW AND GENERAL REAR AREA
LOBBY/PERIMETER AREA/BACK OF HOUSE
KP: KEYPAD-MOUNT 40" AFF WALL ENTERING KITCHEN AREA FROM LOBBY
2-GB: FG 1025 GLASS BREAK-LOBBY GLASS ONE EACH SIDE OF BUILDING SEE DRAWING FOR DEVICEPLACEMENT
3 OR 4-C: B4039 CONTACT-ALL EXTERIOR DOORS BACK DOOR CONTACT TO ACT AS ALARM POINT FORBACK DOOR ALARM-24 HOUR LOCAL POINT-SOUNDER & BLUE STROBE TO ACTIVATE WHEN BACK DOOR ISOPEN
1 OR 2-HUB: 3050CT SERIES LATCHING HUB IN COOLER/FREEZER-MOUNT 18" AFF ON HINGE SIDE OF DOORSUB UP IN CONDUIT
1-POC: POINT OF CONNECTION TO NKL SAFE-PIGTAIL PROVIDED BY NKL SAFE
RELAYS FOR BACK DOOR/POC/ZONE EXPANSIONTELCO JACK , WATTS LINE
ELECTRICAL REQUIREMENTS
ELECTRICAL SUPPLY ALL 120 VAC FOR CAMERA SYSTEM AND BURGLARALARM SYSTEM
SUPPLY 120 VAC FOR ALL CCTV HEAD END EQUIPMENT.SUPPLY 120 VAC FOR BURGLAR ALARM PANEL.FOR OUTDOOR CAMERAS ALL TRENCHING, CONDUIT AND PULLSTRINGS, AS WELLAS A BACK BOX MOUNTED ON THE POLE FOR ELECTRICAL AND COAXCONNECTIONS.
SECURITY CO. SUPPLY AND INSTALL ALL SECURITY EQUIPMENT RUNALL LOW VOLTAGE CABLE FOR THE SECURITY SYSTEM. SET UP, TESTAND TRAIN ON CCTV AND BURGLAR ALARM SYSTEMS. SPECIFY ALLLOCATIONS OF DEVICES.
REFERENCE ONLY
SYMBOL LEGENDDEVICE
A-3
CC
KP
DB-1
SALES
B-4
A-1
C
D
B-5
C
IEIC
PREP
1 SECURITY PLAN1/4" = 1'-0"
3 POPEYES INSTALLATION NOTES
18 SECURITY LEGEND
17 ELECTRICAL REQUIREMENTS