6

Diventures Swim & Scuba

Embed Size (px)

DESCRIPTION

DiVentures Swim & Scuba was founded and headquartered in Omaha, Nebraska in 2009. In 2012 the flagship facility of DiVentures was completed in Springfield, Missouri. Designed by h design group, this state-of-the-art facility features a natatorium with a 25-yard long heated swimming pool, 14-foot deep diving well, changing rooms, modular training areas, a large retail floor displaying swim and scuba gear, and specialized service and repair department that is easily accessible to the general public.

Citation preview

Page 1: Diventures Swim & Scuba
Page 2: Diventures Swim & Scuba

DiVentures

Page 3: Diventures Swim & Scuba

DiVentures

Page 4: Diventures Swim & Scuba

DiVentures

Page 5: Diventures Swim & Scuba

UP

UP

PARTITION TYPES:

OUTSIDE FACE• 5/8" GYPSUM BOARD SHEATHING OVER

EXISTING FRAMINGINSIDE FACE

OUTSIDE FACE• 5/8" GYPSUM BOARD SHEATHING• 3-5/8" METAL STUD FRAMING @ 16" O.C. TO B.O. DECK.

FILL WITH SOUND BATT INSULATION.• 5/8" GYPSUM BOARD SHEATHINGINSIDE FACE

OUTSIDE FACE• 5/8" GYPSUM BOARD SHEATHING• 3-5/8" METAL STUD FRAMING @ 16" O.C. TO B.O. DECK.

FILL WITH SOUND BATT INSULATION.INSIDE FACE

OUTSIDE FACE• 5/8" GYPSUM BOARD SHEATHING• 6" METAL STUD FRAMING @ 16" O.C. TO B.O. DECK. FILL

WITH SOUND BATT INSULATION.• 5/8" GYPSUM BOARD SHEATHINGINSIDE FACE

OUTSIDE FACE• 5/8" GYPSUM BOARD SHEATHING• 6" FURRING (COORDINATE ACTUAL FURRING SIZE WITH

REQUIRED WIDTH OF SHOWER INSERT)• 6" METAL STUD FRAMING @ 16" O.C. TO B.O. DECK. FILL

WITH SOUND BATT INSULATION.• 6" FURRING (COORDINATE ACTUAL FURRING SIZE WITH

REQUIRED WIDTH OF SHOWER INSERT)• 5/8" GYPSUM BOARD SHEATHINGINSIDE FACE

P1A

P4A

P4B

P6A

P6C

1. ALL PARTITION TYPES TO RECEIVE ACOUSTIC SEALANT ON BOTH SIDES OF THEWALL AT TOP AND BOTTOM.

2. ALL PARTITIONS TO RECEIVE WALL BASE ON BOTH SIDES OF WALL. REFER TOINTERIOR DESIGN SHEETS FOR MORE INFORMATION.

3. ANY WALL CONSTRUCTION NOT NOTED WITH A PARTITION TYPE WALL TAGSHALL BE CLARIFIED FOR INTERPRETATION BY THE ARCHITECT PRIOR TOBIDDING.

4. THESE WALL SECTIONS INDICATE PRIMARY WALL TYPE. OVERLAID VENEERS,WAINSCOT, PILASTERS, PAINT, WALL COVERINGS ETC. ARE INDICATED ONFLOOR PLANS, FINISH PLANS, INTERIOR ELEVATIONS, SCHEDULES,SPECIFICATIONS OR OTHER DETAILS.

5. ALL WALLS WITH PLUMBING FIXTURES SHALL RECEIVE MOISTURE AND MOLDRESISTANT GYPSUM BOARD-BASIS OF DESIGN 5/8" FIRE RESISTANT GYPSUMBOARD (GOLDBOND BRAND XP GYP. BD WITH SPORGUARD OR EQUAL), BOTHSIDES OF WALL TYP. UNLESS ABUTTING SURFACE.

6. CONTRACTOR SHALL COORDINATE WALL FRAMING ABOVE FINISHED CEILINGSWITH FRAMING, PLUMBING, AND HVAC CONTRACTORS. FRAMING CONTRACTORSHALL PROVIDE NECESSARY ROUGH OPENING FRAMING REQUIRED TOFACILITATE PIPING OR DUCTWORK PENETRATIONS - REFER TO MEPENGINEERING DRAWINGS FOR LOCATIONS OF LOCATIONS OF NEW / EXISTINGDUCTS, PIPING, ETC. SOME WALL FRAMING / BRACING MAY REQUIREADJUSTMENT OR RE-LOCATION TO ALLOW FOR DUCT / PIPE ROUTING.

7. REFER TO U.L. DESIGN DIRECTORY FOR LISTED DESIGN NUMBERS NOTINDICATED.

8. ASSEMBLIES SHOULD BE AIRTIGHT. SEAL ALL PENETRATIONS AND CRACKSWITH ACOUSTICAL SEALANT.

OUTSIDE FACE• 5/8" GYPSUM BOARD SHEATHING• 1-5/8" METAL STUD FURRING @ 16" O.C. TO B.O. DECK.• 8" CMU WALL - SEE STRUCTURAL FOR MORE INFORMATIONINSIDE FACE*UL DESIGN U906 TO BE FOLLOWED - 2-HOUR RATING(1-HOUR REQUIRED)

OUTSIDE FACE• 6" METAL STUD FURRING @ 16" O.C. TO B.O. DECK. FILL

WITH SOUND BATT INSULATION.• 8" CMU WALL - SEE STRUCTURAL FOR MORE INFORMATIONINSIDE FACE

P8A

P8B

OUTSIDE FACE• 4" ARCHITECTURAL MIX CONCRETE. SEE SPECIFICATIONS

FOR MORE INFORMATION.• 3" RIGID INSULATION. SEE SPECIFICATIONS FOR MORE

INFORMATION.• 4" INTERIOR STRUCTURAL MIX CONCRETE. SEE

SPECIFICATIONS FOR MORE INFORMATION.INSIDE FACE

P11

P2AOUTSIDE FACE• 5/8" GYPSUM BOARD SHEATHING• 1-5/8" METAL STUD FRAMING @ 16" O.C. TO B.O. DECK

OVER EXISTING CMU WALLINSIDE FACE

OUTSIDE FACE• 5/8" GYPSUM BOARD SHEATHING• 6" METAL STUD FRAMING @ 16" O.C. TO 42" A.F.F. WRAP

GYP. BD. OVER TOP STUD TRACK.• 5/8" GYPSUM BOARD SHEATHINGINSIDE FACE

P6B

STAT E OF NEBRASK

A

A R C H I T E C T

NUMBER

© 2015 H DESIGN GROUP, LLC

This drawing and the architectural work represented areowned by hdesign group, llc. Copyright includes thisdrawing as well as all components of the conceptual design.Reproduction of any kind is strictly prohibited without theexpressed written consent of hdesign group, llc.

Client

Professional Seal

New Project for:

Revisions

Consultants

SheetProject No:Drawn By:Reviewed By:Date:

1

2

3

4

5

6

7

8

9

10

11

A B C D E F G H J K L M N P R

A B C D E F G H J K L M N P R

1

2

3

4

5

6

7

8

9

10

11

BRENT M.STEVENS

NE# A-4205

DiVentures - Omaha4303 S. 121st PlazaOmaha, NE 68137

DiVentures Scuba & Swim Centers4303 S. 121st PlazaOmaha, NE 68137402-933-6251Client Fax/OtherMark Roberts ([email protected])

Brent M. Stevens, AIAProfessional Title: ArchitectNE# A-4205

A1.2

FLOOR PLAN - PHASE 2

15-022

10/26/2015

JDL, NBSNBS

Pinnacle Design Consultants, LLC - Civil Engineer304-B W. Erie St.Springfield, MO 65807417-501-8820Ron Hamme ([email protected])-J & M Engineering - Structural Engineer3041 S Kansas ExpySpringfield, MO 65807417-208-5120Ben Jennings ([email protected])-Malone Finkle Eckhardt & Collins, Inc.333 E Battlefield Rd Suite 1000Springfield, MO 65804417-881-0020Cameron Collins ([email protected])-New Wave Pools & Spas, Inc.13312 Giles RoadOmaha, NE 68138402-672-6484402-235-3836Darcy Schatz---

scale: 3/32" = 1'-0"A1.21D FIRST FLOOR - NEW PHASE 2

TRUE NORTH

KEYNOTE LEGEND

Key Value Keynote Text

A1 POOL DECK SHOWER SCREENS - SIZE TO BE 23" WIDE X 42" TALL WITH BOTTOM OF SCREEN MOUNTED@ 18" A.F.F. SEE A7.1 AND SPECIFICATIONS FOR MORE INFORMATION. OPERATIONAL LEVERS/KNOBSOF SHOWER HEAD TO BE MOUNTED 42" A.F.F. SHOWER HEADS TO BE MOUNTED 72" A.F.F. ADA UNITIS TO HAVE TWO-WALL SHOWER GRAB BAR - BASIS-OF-DESIGN IS TO BE BOBRICK B-6861

No. Description Date

DiVentures

Page 6: Diventures Swim & Scuba

Springfield, Missouri is host to DiVentures’ new flagship store—which is a 11,800-square foot state-of-the-art facility. The facility features a natatorium with a 25-yard long heated swimming pool, 14-foot deep diving well, changing rooms, modular training areas, a large retail floor displaying swim and scuba gear, and specialized service and repair department that is easily accessible to the general public.

DiVentures is headquartered out of Omaha, Nebraska and offers a full range of aquaticprograms, including: scuba training, swim lessons, fitness training, and travel.