Plus de 1200 produits disponibles sous 24 heures
More than 1200 products can be dispatched within 24 hours
DIREKT.Transformateurs / Alimentations / Disjoncteurs / Inductances / Filtres CEMTransformers / Power supplies / Circuit breakers / Reactors / EMI filters
Édition 8 Edition 8FR
EN
BLOCK
block.eu
Transformateurs Transformers
AlimentationsPower supplies
Inductances / Filtres CEM
Reactors / EMI filters
MADE BY BLOCK
2Sujet à modification
Subject to change
Factory 1, Verden, Germany 30 000 m² production area
BLOCK Direkt: simple et rapideBLOCK Direkt: easy and fast
EMPLOYEES1200
ENGINEERS & TECHNICIANS
60LOCATIONS WORLDWIDE
38
3Sujet à modification
Subject to change
Perfecting power Success needs space to grow: at a production facility of over 35 000 m² and with over 1 200 employees, BLOCK develops products and solutions with optimum voltage and power quality in every single area of business and industry. Maximum precision and highly intelligent solutions are what we strive for day in, day out. We guarantee maximum power quality with sophisticated, energy-efficient solutions. In our latest edition of BLOCK Direkt, you will find details of over 1 200 products for all requirements around the interface to the mains. Experience all this for yourself, we look forward to receiving your order. Your BLOCK Direkt team
How do I place an order? All products listed in this BLOCK Direkt catalog can be dis-patched in Germany within 24 hours. Furthermore, we also have extensive warehousing in China and the United States. Information relating to products and their fields of application you can get via:
block.eu
France: +33 4 72 75 19 19 Northern France/Belgium: +32 1669-6945
Contract distributors/wholesalers (see back of the catalog)
Le courant à la perfectionLa réussite a besoin d’espace: avec une surface de pro-duction de plus de 35 000 m2 et plus de 1 200 salariés, BLOCK développe des produits et solutions pour une qualité optimale de tension et de réseau pour tous les secteurs économiques et industriels. Nos objectifs sont la précision maximale et l’offre de solutions innovantes. Nous vous ga-rantissons une qualité d’énergie et un rendement optimisés.
Dans cette dernière édition de BLOCK Direkt, vous trou-verez plus de 1 200 produits pour tous vos besoins en ali-mentation électrique. N’attendez plus et venez les découvrir en parcourant les pages suivantes! Votre équipe BLOCK
Comment passer commande? Tous les produits du catalogue BLOCK Direkt peuvent être livrés sous 24 heures en Allemagne. De plus, nous dispo-sons d’un stock important en Chine et aux Etats-Unis. De plus amples informations sur les produits et leurs applica-tions sont disponibles via:
block.eu
France: +33 4 72 75 19 19 Nord de la France/Belgique: +32 1669-6945
Distributeurs (voir au verso du catalogue)
Factory Franklin Park, USA 2 500 m² production area
Factory Kunshan, China 1 800 m² production area
Factory 2, Verden, Germany 2 500 m² production area
BLOCK Direkt: simple et rapideBLOCK Direkt: easy and fast
LOCATIONS WORLDWIDE
38
Sujet à modificationSubject to change4
Sommaire Content
à partir de la page from page 8
NouveautésNews
Transformateurs Transformers
Transformateurs Transformers
Transformateurs toriques Toroidal transformers
Limiteurs de courant Inrush current limiters
Alimentations de courant alternatif pour laboratoires Laboratory power supplies
Coffrets en tôle d’acier Sheet-metal enclosures
Transformateurs pour circuit-imprimé PCB transformers
Composants inductifs et bobines de réactance Inductive components and reactors Transformateurs moyenne fréquence Medium-frequency transformers
à partir de la page from page 12
1
Boîtiers en plastique Plastic housings
Alimentations secourues Uninterruptible power supplies
Inductances de ligne Line reactorsFuture Winding
5Sujet à modification
Subject to change
à partir de la page from page 90
Tests CEM EMC tests
Tests mécaniques Mechanical tests
Simulations de l’environnement Environmental simulations
à partir de la page from page 64
Inductances/Filtres CEMReactors/EMI filters
Inductances de ligne Line reactors
Inductances pour circuit de filtrage Detuned reactors Filtres anti-harmoniques Harmonic filters
Filtres d’antiparasitage Radio interference suppression filters
Stabilisateurs de tension Voltage stabilizers
Inductances moteur dv/dt-filtres Motor reactors dv/dt-filter Filtre sinusoïdal Sine filters
Alimentations Power supplies
Alimentations à découpage Switched mode power supplies
Pilote de LED LED drivers
Disjoncteurs électroniques Electronic circuit breakers
Modules de redondance Redundancy modules
Alimentations secourues Uninterruptible power supplies
Modules batterie Battery modules
Modules tampon Buffer modules
Alimentations CC Transformer power supplies
2 3ServicesServices
à partir de la page from page 106
Sujet à modificationSubject to change6
Catégorie EntrepriseCategory Company
Veuillez utiliser les données BLOCK disponibles sur le portail ePLAN Data Portal pour une planification rapide du
projet et une optimisation du flux de travail.
Please use the provided data sets of BLOCK in the ePLAN Data Portal for a
fast project planning and optimization of the workflow.
7Sujet à modification
Subject to change
+ V
+ V
EQU
ab
αβGbeta
Galpha
MovingAverage
CONST
ab
αβGbeta
Galpha
αβ
dq
Gq
Gd
Gbeta
Galpha
Out
Ist
Soll
Ist
Out
Soll
Out
Ist
Soll
αβ
dqGdGbeta
Galpha
GAIN
dq
αβGbeta
Galpha
Gq
Gd
αβ
Gb
Ga
Gbeta
Galpha PWM
17
+V
A
180.00 185.00 190.00 195.00 200.00Time [ms]
-20
0
20
AM1.
I [A]
Curve InfoAM1.I
TR
A
ICA:
CONST
0
0.00 2.00 4.00 6.00 8.00 10.00Spectrum [kHz]
0.00
0.50
1.00
1.50
2.00
mag
(AM
1.I)
[A]
Curve Infomag(AM1.I)
TR
Catégorie Technologies Category Technologies
TECHNOLOGIES DE SIMULATION BLOCKBLOCK SIMULATION TECHNOLOGIES
Le logiciel de simulation An-sys Simplorer permet de mo-déliser les systèmes clients afin de simuler le comportement électrique de nos produits dans les applications réelles. Les modèles utilisés sont unique-ment disponibles chez BLOCK.
Ansys Simplorer simulation software enables customer systems to be modeled in order to simulate the electrical behavior of our products in actual applications. The mod-els used are only available at BLOCK.
taid est un système de calcul propriétaire de BLOCK qui permet de calculer et de dimen-sionner les produits enroulés inductifs d’un point de vue magnétique, électrique et ther-moanalytique. Les algorithmes de calcul ont été développés par BLOCK dans cette optique,permettant à nos clients de bénéficier de notre expertise théorique unique et de nos con-naissances pratiques sur les technologies avancées.
taid is BLOCK’s proprietary calculation system and enables inductive coiled products to be magnetically, electrically and thermo-analytically calculated and dimensioned. The calcula-tion algorithms were developed by BLOCK with this in mind, allowing our customers to ben-efit from our unique theoretical expertise and technologically advanced knowledge.
COMSOL Multiphysics est un logiciel conçu pour simuler les processus physiques. Ce programme est basé sur la méthode des éléments finis (FEM). COMSOL nous permet de calculer des développe-ments spécifiques, ainsi que de procéder à des simulations de certains phénomènes élec-triques, magnétiques, ther-miques, statiques et de flux.
COMSOL Multiphysics is a software program designed to simulate physical processes. The program is based on the so-called finite element method (FEM). COMSOL allows us to calculate special developments, certain phenomenons, electri-cal, magnetic, thermal, flow and static simulations.
Catégorie Transformateurs Nouveautés Category Transformers News
NOUVEAU NEW
TOGA
BOÎTIERS UNIVERSELS EN PLASTIQUE TOGA UNIVERSAL PLASTIC HOUSINGS TOGA
Il faut du temps pour trouver les bonnes idées... les très bonnes idées s’imposent.TOGA a été conçu avec des fixations murales pour les transformateurs jusqu’à 450 VA et d’autres applications. Avec une entrée et une sortie d’un côté, des bor-niers isolés pour une séparation des circuits d’alimentation et de commande ainsi que des borniers à décharge de traction, il est facile de procéder à un ajustement spécifique pour chaque application.
Good ideas take time, very good ideas their own space. TOGA was engineered with wall fastening for transformers up to 450 VA and other applications. One-sided in- and outlet, plus isolated terminal areas for a separation of feeder and control circuits as well as individual terminal areas with strain-relief provide an application-specific adjustment.
Page 49 Page 49
UNBOX YOUR IDEAS
8Sujet à modificationSubject to change
Catégorie Alimentations secourues Nouveautés Category Uninterruptible power supplies News
NOUVEAU NEW
La nouvelle ASI sur batterie offre une disponibilité maxi-male des installations grâce à une gestion intelligente de la batterie et des temps de charge plus courts, même avec d’importantes capacités de batterie. Jusqu’à 40 Asont disponibles sans interruption en cas de panne de courant au sein de réseaux 12 V, 24 V et 48 V. La surveil-lance permanente des batteries connectées permet un avertissement précoce en cas de faible durée devie restante. En plus du paramétrage, un aperçu perma-nent des états de service de l’ASI est assuré grâce au logiciel de configuration performant USV-Control.
The new battery-powered UPS offers the highest system availability through intelligent battery management and short charging times, even with large battery capacities. In the event of a power failure, they can be used in 12 V, 24 V and 48 V mains up to 40 A without power inter-ruption. As the connected batteries are permanently monitored, an early warning is issued in the event of low remaining service life. In addition to parameterization, the powerful configuration software UPS control also ensu-res an overview of the operating conditions of the UPS at all times.
HIGHLIGHTS
COURANT DE SORTIE JUSQU’À 40 A UP TO 40 A OUTPUT VOLTAGE
COURANT DE CHARGE 5 A POUR DES TEMPS DE CHARGE PLUS COURTS 5 A CHARGING CURRENT FOR SHORT CHARGING TIMES
DÉMARRAGE SUR BATTERIE START FROM BATTERY
ONDULEUR 40 A AVEC BATTERIE OU CONDENSATEURS PC 40 A BATTERY-POWERED AND CAPACITIVE UPS PC
Page 83 Page 83
La ASI capacitive fondée sur des ultracondensa-teurs offre une plus longue durée de vie même à des températures ambiantes élevées et ainsi une plus grande sécurité au sein de réseaux 24 V. Avec le mo-dule de base, des courants sans interruption jusqu’à 20 A sont assurés en cas de panne de courant. Le courant de sortie peut être augmenté jusqu’à 40 A et le temps de mise en mémoire tampon peut ainsi être adapté aux exigences grâce à des possibilités d’extension flexibles en connectant des modules de capacité supplémentaires. Toutes les données corre-spondantes peuvent être consultées à tout moment par l’intermédiaire d’un port USB galvaniquement isolé.
The new capacitive UPS is based on ultra-capacitors and provides a long service life, even at high ambient temperatures. It also therefore offers higher safety levels in 24 V networks. During a power failure, the basic module provides uninterrupted currents of up to 20 A. Thanks to flexible expansion options, the output current can be increased to 40 A by connec-ting additional capacity modules and the buffer time can be scaled as required. All relevant data can be retrieved at any time from a potential-separated USB interface.
HIGHLIGHTS
COURANTS DE SORTIE JUSQU’A 40 A AVEC MODULE DE CONDENSATEURS UP TO 40 A OUTPUT VOLTAGE WITH CAPACITY MODULE
COURANT DE CHARGE 3 A POUR DES TEMPS DE CHARGE PLUS COURTS 3 A CHARGE CURRENT FOR SHORT CHARGING TIMES
DENSITÉ DE PUISSANCE ÉLEVÉE HIGH POWER DENSITY
Page 82 Page 82
9Sujet à modification
Subject to change
Catégorie Inductance/Filtres CEM Nouveautés Category Reactors/EMI filters News
NOUVEAU NEW
La nouvelle technologie Future Winding de BLOCK développée en interne, fait entrer l’optimisation des performances des produits de bobinage inductif dans une nouvelle dimension. La variabilité extraordinaire de conception de la structure de bobinage est proposée avec un grand nombre d’avantages pour les produits bobinés: Un refroidissement optimal avec la maximisation de la surface conductrice émettrice de chaleur tout en créant aussi des conduits de refroidissement via la structure du bobinage et des pertes de proximité minimales avec des fréquences de commutation croissantes sont seulement quelques points forts de cette innovation à la pointe de la technologie.
BLOCK’s new in-house developed Future Winding technology is taking performance optimization of inductive winding products into a new dimension. The extraordinary variability in the design of the winding structure comes with a number of benefits for winding products: Optimal cooling by maximizing the heat-emitting conductor surface while also creating cooling ducts via the winding structure and minimal proximity losses with rising switching frequencies are just some of the strengths of this state-of-the-art technology.
I nduc t i ve so lu t ions for SiC , GaN – W ide bandgap t echno logy
Future Winding for nex t power genera t ion
Excellente dissipation thermique en raison de la nouvelle conception du bobinage
excellent heat dissipation due to new winding design
0
10
20
30
40
50
60
70
80
90
0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000
P AC/
P DC
f in Hz
conventional winding Future Winding
Effet de proximité minimisé grâce à une structure de bobinage optimisée
proximity effect through optimized winding structure
10Sujet à modificationSubject to change
Catégorie Inductance/Filtres CEM Nouveautés Category Reactors/EMI filters News
NOUVEAU NEW
HIGHLIGHTS
UNE EXCEPTIONNELLE DISSIPATION THERMIQUE EXCEPTIONAL HEAT DISSIPATION
UN EFFET DE PROXIMITÉ RÉDUIT REDUCED PROXIMITY EFFECT
UNE FIABILITÉ MAXIMALE AVEC UN MINIMUM DE MATÉRIAUX ISOLANTS MAXIMUM RELIABILITY WITH A MINIMUM OF INSULATION MATERIALS
UNE DISTRIBUTION DU CHAMP MAÎTRISABLE POUR UNE DÉCHARGE PARTIELLE FAIBLE CONTROLLABLE FIELD DISTRIBUTION FOR LOW PARTIAL DISCHARGE
DENSITÉS DE COURANT ÉLEVÉES RÉALISABLES EN RAISON DE LA SURFACE ÉTENDUE DU BOBINAGE HIGHEST CURRENT DENSITIES ACHIEVEABLE DUE TO EXPANDED WINDING SURFACE
Page 93 Page 93
INDUCTANCES DE LIGNE LR3-A LINE REACTOR LR3-A
Les inductances en ligne de la série LR3-A combinent tous les avantages de la technologie Future Winding. Le recours à ces dispositifs minimise les perturba-tions du système et comble les irrégularités de commutation, pour le protéger. La réduction du pourcentage de puissance réactive contribue à améliorer le facteur de puissance. Grâce à la toute dernière technologie de bobinage et de production associée aux derniers résultats scientifiques, les inductances en ligne proposent un rapport prix-performance «le meilleur de sa catégorie».
The line reactors of the LR3-A series combine all the advantages of Future Winding technology. Using these minimizes system perturbations and bridges commutating notches, thus protecting the system. Reducing the reactive power percentage contributes to improving the power factor. Thanks to the latest win-ding and production technology in combination with the latest scientific findings, the line reactors offer a “best-in-class” price-performance ratio.
11Sujet à modification
Subject to change
Transformateurs Transformers
AlimentationsPower supplies2Inductances/Filtres CEMReactors/EMI filters3
NouveautésNews0
ü Transformateurs Transformersü Transformateurs toriques Toroidal transformers ü Limiteurs de courant Inrush current limiters ü Alimentations de courant alternatif pour laboratoires Laboratory power supplies ü Coffrets métalliques Sheet-metal enclosuresü Transformateurs pour circuit-imprimé PCB transformersü Composants inductifs et bobines de réactance Inductive components and reactors
1
12Sujet à modificationSubject to change
1
13
Transformateurs Transformers1
Aperçu des transformateurs de commande Overview control transformers
Outre notre service de livraison sous 24 h, découvrez notre gamme de produits standard. Pour plus d’informations, n’hésitez pas à consulter notre site block.eu.
In addition to our 24 hours BLOCK direct sales program an overview of the entire standard range. For more information see block.eu.
TypeType Tens
ion
d’en
trée
nom
inal
eRa
ted
inpu
t vol
tage
Tens
ion
de s
ortie
nom
inal
eRa
ted
outp
ut v
olta
ge
Puis
sanc
ePo
wer
Born
es à
ress
ort
Sprin
g-loa
ded
term
inals
Born
es à
vis
Scre
w te
rmina
ls
Tens
ion
d’ent
rée
doub
leDu
al inp
ut vo
ltage
Tens
ions
d’ent
rée
unive
rsell
esUn
ivers
al inp
ut vo
ltage
Jusq
u’à 2
50VA
avec
seme
lle co
mbiné
epo
ur un
mon
tage
à vis
et su
r rail
DIN
Up to
250
VA w
ith c
ombin
ation
foot
plate
for b
olted
and
rail m
ount
ing
Tran
sfor
mat
eur d
’isole
men
tIso
lating
tran
sfor
mer
STE230 V ± 5 % 24% 24 V 63 – 500 VA r r rr r
400 V ± 5 % 24% 24 V 63 – 500 VA r r rr r
400 V ± 5 % 230% 230 V 63 – 2500 VA r r rr r
STEU 230 / 400 V± 15 V
2 x 12 V 63 – 1000 VA r r r rr r
2 x 24 V 63 – 1000 VA r r r rr r
2 x 115 V 63 – 2500 VA r r r rr r
USTE 208 – 600 V2 x 12 V 100 – 630 VA r r r rr r rr r r
2 x 115 V 100 – 3200 VA r r r rr r rr r r
ST
230 V ± 5 % 12% 12 V 20 – 250 VA r r
230 V ± 5 % 24% 24 V 20 – 400 VA r r
230 V ± 5 % 42% 42 V 250 VA r r
230 V ± 5 % 110% 110 V 130 VA r r
230 V ± 5 % 230% 230 V 20 – 1000 VA r r
400 V ± 5 % 24% 24 V 63 – 400 VA r r
400 V ± 5 % 42% 42 V 63 VA r r
400 V ± 5 % 230% 230 V 20 – 2500 VA r r
440 V ± 5 % 230% 230 V 63 – 1000 VA r r
500 V ± 5 % 230% 230 V 1000 VA r r
690 V ± 5 % 230% 230 V 63 – 2500 VA r r
STU 210 – 540 V± 20 V
24 V 63 – 800 VA r r r
2 x 115 V 63 – 2500 VA r r r
STSU 230 / 400 V± 15 V
2 x 12 V 40 – 1000 VA r r rr r rr r r * r
2 x 24 V 40 – 1000 VA r r rr r rr r r * r
2 x 115 V 40 – 2500 VA r r rr r rr r r * r
TT1
219 / 230 / 241 V 24 V 1000 – 2500 VA r r
380 / 400 / 420 V42 V 1600, 2500 VA r r
2 x 115 V 1000 – 25000 VA r r
BUST
230 V ± 5 % 24% 24 V 1000 – 1600 VA r
230 V ± 5 % 2 x 115% 2 x 115 V 2000 – 5000 VA r
400 V ± 5 % 42% 42 V 1600 VA r
400 V ± 5 % 2 x 115% 2 x 115 V 1000 – 10000 VA r
440 V ± 5 % 2 x 115% 2 x 115 V 3000 – 6300 VA r
500 V ± 5 % 2 x 115% 2 x 115 V 3000 – 6300 VA r
* seulement 63 – 250 VA * only 63 – 250 VA
14Sujet à modificationSubject to change
Transformateur de commande, de sécurité et deséparation des circuitsControl- and safety isolating- resp. isolatingtransformerSTE
W J 2 " |
AVANTAGES BENEFITS
Courant d’appel réduit
Prises côté primaire jusqu’à ±5 %permettant l’adaptation de la tension
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Durée de câblage réduite grâce auxbornes à ressort
Jusqu’à 250 VA avec semelle combinéepour un montage à vis et sur rail DIN
Reduced inrush current
Primary side ±5 % taps for voltageadjustment
Very good corrosion protection and lownoise due to vacuum impregnation
Fast installation because of the use ofcage-clamp terminals
DIN rail clamp included up to 250 VA
APPLICATIONS APPLICATIONS
Comme un transformateur decommande pour un isolementélectrique sûr entre l’entrée et lasortie.
Comme un transformateur deséparation des circuits pour unisolement électrique sûr entre l’entréeet la sortie.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
As a control transformer for theelectrical isolation of the input andoutput sides.
As an isolating transformer for thesafe electrical isolation of the input andoutput sides.
As a safety isolating transformer forthe safe electrical isolation of the inputand output sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 95 %, Indice de protection IP 00 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 95 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
STE 63/23/24 230 24 63 78/88/85STE 63/4/24 400 24 63 78/88/85STE 63/4/23 400 230 63 78/88/85STE 100/23/24 230 24 100 84/96/85STE 100/4/23 400 230 100 84/96/85STE 160/23/24 230 24 160 96/104/102STE 160/4/23 400 230 160 96/104/102STE 250/23/24 230 24 250 96/104/102STE 250/4/24 400 24 250 96/104/102STE 250/4/23 400 230 250 96/104/102
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
STE 320/23/24 230 24 320 105/110/103STE 320/4/23 400 230 320 105/110/103STE 400/23/24 230 24 400 120/121/104STE 400/4/23 400 230 400 120/121/104STE 500/23/24 230 24 500 120/121/124STE 500/4/24 400 24 500 120/121/124STE 500/4/23 400 230 500 120/121/124STE 630/4/23 400 230 630 150/143/113STE 800/4/23 400 230 800 150/143/130STE 1000/4/23 400 230 1.000 150/143/156STE 1600/4/23 400 230 1.600 192/181/145STE 2000/4/23 400 230 2.000 192/181/161STE 2500/4/23 400 230 2.500 192/181/183
Transformateurs Transformers 1
15Sujet à modification
Subject to change
Transformateur de commande, de sécurité et deséparation des circuitsControl- and safety isolating- resp. isolatingtransformerSTEU
W J 2 " |
AVANTAGES BENEFITS
Tension d’entrée 230 V et 400 V
Courant d’appel réduit
Prises côté primaire jusqu’à ±15 Vpermettant l’adaptation de la tension
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Durée de câblage réduite grâce auxbornes à ressort
Jusqu’à 250 VA avec semelle combinéepour un montage à vis et par rail DIN
Dual input voltage 230 and 400 Vac
Reduced inrush current
Primary side ±15 V taps for voltageadjustment
Very good corrosion protection and lownoise due to vacuum impregnation
Fast installation because of the use ofcage-clamp terminals
DIN rail clamp included up to 250 VA
APPLICATIONS APPLICATIONS
Comme un transformateur decommande pour un isolementélectrique sûr entre l’entrée et lasortie.
Comme un transformateur deséparation des circuits pour unisolement électrique sûr entre l’entréeet la sortie.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
As a control transformer for theelectrical isolation of the input andoutput sides.
As an isolating transformer for thesafe electrical isolation of the input andoutput sides.
As a safety isolating transformer forthe safe electrical isolation of the inputand output sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 94 %, Indice de protection IP 00 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 94 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
STEU 63/23 230/400 2 x 115 63 84/88/85STEU 63/24 230/400 2 x 12 63 84/88/85STEU 100/23 230/400 2 x 115 100 84/88/85STEU 100/24 230/400 2 x 12 100 84/96/85STEU 160/23 230/400 2 x 115 160 96/104/102STEU 160/24 230/400 2 x 12 160 96/104/102STEU 250/23 230/400 2 x 115 250 96/105/125STEU 250/24 230/400 2 x 12 250 96/104/125
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
STEU 320/23 230/400 2 x 115 320 120/121/92STEU 320/24 230/400 2 x 12 320 120/121/92STEU 400/23 230/400 2 x 115 400 120/121/104STEU 400/24 230/400 2 x 12 400 120/121/104STEU 500/23 230/400 2 x 115 500 120/121/124STEU 500/24 230/400 2 x 12 500 120/121/124STEU 630/23 230/400 2 x 115 630 150/145/117STEU 630/24 230/400 2 x 12 630 150/145/117STEU 800/23 230/400 2 x 115 800 150/143/130STEU 800/24 230/400 2 x 12 800 150/143/130STEU 1000/23 230/400 2 x 115 1.000 150/143/156STEU 1000/24 230/400 2 x 12 1.000 150/185/180STEU 1600/23 230/400 2 x 115 1.600 192/181/161STEU 2000/23 230/400 2 x 115 2.000 192/181/183STEU 2500/23 230/400 2 x 115 2.500 192/181/190
Transformateurs Transformers1
16Sujet à modificationSubject to change
Transformateur universel de commande, de sécurité etde séparation des circuitsUniversal control- and safety isolating- resp. isolatingtransformerUSTE
W J 2 " |
AVANTAGES BENEFITS
Tension d’entrée de 208 V à 600 V
Courant d’appel réduit
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Durée de câblage réduite grâce auxbornes à ressort
Jusqu’à 250 VA avec semelle combinéepour un montage à vis et sur rail DIN
Universal input voltages208 to 600 Vac
Reduced inrush current
Very good corrosion protection and lownoise due to vacuum impregnation
Fast installation because of the use ofcage-clamp terminals
DIN rail clamp included up to 250 VA
APPLICATIONS APPLICATIONS
Comme un transformateur decommande pour un isolementélectrique sûr entre l’entrée et lasortie.
Comme un transformateur deséparation des circuits pour unisolement électrique sûr entre l’entréeet la sortie.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
As a control transformer for theelectrical isolation of the input andoutput sides.
As an isolating transformer for thesafe electrical isolation of the input andoutput sides.
As a safety isolating transformer forthe safe electrical isolation of the inputand output sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 96 %, Indice de protection IP 00 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 96 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
USTE 100/2x12 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x12 100 84/96/85
USTE 100/2x115 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x115 100 84/96/85
USTE 250/2x12 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x12 250 96/104/102
USTE 250/2x115 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x115 250 96/104/102
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
USTE 400/2x12 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x12 400 120/121/104
USTE 400/2x115 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x115 400 120/121/104
USTE 630/2x12 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x12 630 150/143/117
USTE 630/2x115 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x115 630 150/143/118
USTE 800/2x115 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x115 800 150/143/130
USTE 1000/2x115 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x115 1.000 150/143/164
USTE 1200/2x115 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x115 1.200 150/143/164
USTE 1600/2x115 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x115 1.600 192/181/144
USTE 2500/2x115 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x115 2.500 192/181/188
USTE 3200/2x115 208/230/ 380/400/415/440/ 460/480/500/525/ 550/575/600
2x115 3.200 231/246/223
Transformateurs Transformers 1
17Sujet à modification
Subject to change
Transformateur de commande, de sécurité et deséparation des circuitsControl- and safety isolating- resp. isolatingtransformerST
W w J 2 " |
AVANTAGES BENEFITS
Courant d’appel réduit
Prises côté primaire ±5 % permettantl’adaptation de la tension
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Reduced inrush current
Primary side ±5 % taps for voltageadjustment
Very good corrosion protection and lownoise due to vacuum impregnation
APPLICATIONS APPLICATIONS
Comme un transformateur decommande pour un isolementélectrique sûr entre l’entrée et lasortie.
Comme un transformateur deséparation des circuits pour unisolement électrique sûr entre l’entréeet la sortie.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
As a control transformer for theelectrical isolation of the input andoutput sides.
As an isolating transformer for thesafe electrical isolation of the input andoutput sides.
As a safety isolating transformer forthe safe electrical isolation of the inputand output sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 96 %, Indice de protection IP 00 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 96 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
ST 20/4/23 400 230 20 66/81/56ST 20/23/12 230 12 20 66/81/56ST 20/23/23 230 230 20 66/81/56ST 20/23/24 230 24 20 66/81/56ST 63/4/23 400 230 63 78/89/60ST 63/69/23 690 230 63 78/89/60ST 100/4/23 400 230 100 84/95/76ST 100/69/23 690 230 100 84/95/76ST 130/69/23 690 230 130 96/105/78ST 160/4/23 400 230 160 96/103/88ST 160/69/23 690 230 160 96/103/88ST 250/4/23 400 230 250 96/105/103ST 250/69/23 690 230 250 96/105/103ST 320/4/23 400 230 320 105/114/103ST 320/69/23 690 230 320 105/114/103ST 400/4/23 400 230 400 120/123/110ST 400/69/23 690 230 400 120/123/110ST 500/4/23 400 230 500 120/123/122ST 500/69/23 690 230 500 120/123/122
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
ST 630/4/23 400 230 630 150/148/111ST 630/69/23 690 230 630 150/148/111ST 800/4/23 400 230 800 150/148/128ST 800/69/23 690 230 800 150/148/128ST 1000/4/23 400 230 1.000 150/148/154ST 1000/69/23 690 230 1.000 150/148/154ST 1600/4/23 400 230 1.600 192/182/146ST 1600/69/23 690 230 1.600 192/182/146ST 2000/4/23 400 230 2.000 192/182/162ST 2000/69/23 690 230 2.000 192/182/162ST 2500/4/23 400 230 2.500 192/185/185ST 2500/69/23 690 230 2.500 192/185/185
Transformateurs Transformers1
18Sujet à modificationSubject to change
Transformateur universel de commande, de sécurité etde séparation des circuitsUniversal control- and safety isolating- resp. isolatingtransformerSTU
W w J 2 " |
AVANTAGES BENEFITS
Tensions d’entrée universellesde 210 à 540 V CA
Courant d’appel réduit
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Universal input voltages210 to 540 Vac
Reduced inrush current
Very good corrosion protection and lownoise due to vacuum impregnation
APPLICATIONS APPLICATIONS
Comme un transformateur decommande pour un isolementélectrique sûr entre l’entrée et lasortie.
Comme un transformateur deséparation des circuits pour unisolement électrique sûr entre l’entréeet la sortie.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
As a control transformer for theelectrical isolation of the input andoutput sides.
As an isolating transformer for thesafe electrical isolation of the input andoutput sides.
As a safety isolating transformer forthe safe electrical isolation of the inputand output sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 95 %, Indice de protection IP 00 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 95 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
STU 63/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 63 84/94/76
STU 100/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 100 84/94/90
STU 160/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 160 96/105/92
STU 250/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 250 120/123/92
STU 400/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 400 120/123/105
STU 500/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 500 120/123/124
STU 630/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 630 150/149/112
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
STU 800/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 800 150/149/128
STU 1000/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 1.000 150/149/156
STU 1600/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 1.600 192/182/146
STU 2000/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 2.000 192/182/183
STU 2500/2x115 210/230/250/380/400/420/440/460/480/500/520/540
2x115 2.500 192/182/190
Transformateurs Transformers 1
19Sujet à modification
Subject to change
Transformateur de commande, de sécurité et deséparation des circuits, avec écran électrostatiqueControl- and safety isolating- resp. isolatingtransformer with shielding windingSTSU
W J 2 " |
AVANTAGES BENEFITS
Tension d’entrée 230 V et 400 V
Enroulement d’un écran entre PRI etSEC
Courant d’appel réduit
Puissance élevée pour unencombrement réduit grâce à uneconstruction compacte
Prises côté primaire jusqu’à ±15 Vpermettant l’adaptation de la tension
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
63 - 250 VA avec semelle combinéepour un montage à vis et sur rail DIN
Dual input voltage 230 and 400 Vac
Schielding winding between input andoutput
Reduced inrush current
High power density due to a compactconstruction design
Primary side ±15 V taps for voltageadjustment
Very good corrosion protection and lownoise due to vacuum impregnation
DIN rail clamp included 63 - 250 VA
APPLICATIONS APPLICATIONS
Comme un transformateur decommande pour un isolementélectrique sûr entre l’entrée et lasortie.
Comme un transformateur deséparation des circuits pour unisolement électrique sûr entre l’entréeet la sortie.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
As a control transformer for theelectrical isolation of the input andoutput sides.
As an isolating transformer for thesafe electrical isolation of the input andoutput sides.
As a safety isolating transformer forthe safe electrical isolation of the inputand output sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de 40 °C max., Degré d’efficacité jusqu’à 94 %, Indice deprotection IP 00 Maximum ambient temperature 104 °F / 40 °C, Efficiency up to94 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
STSU 40/23 230/400 2x115 40 66/78/82STSU 40/24 230/400 2x12 40 66/78/82STSU 40/48 230/400 2x24 40 66/78/82STSU 63/23 230/400 2x115 63 84/88/89STSU 63/24 230/400 2x12 63 84/88/89STSU 63/48 230/400 2x24 63 84/88/89STSU 100/23 230/400 2x115 100 84/96/97STSU 100/24 230/400 2x12 100 84/96/97STSU 100/48 230/400 2x24 100 84/96/97STSU 160/23 230/400 2x115 160 96/104/102STSU 160/24 230/400 2x12 160 96/104/102STSU 160/48 230/400 2x24 160 96/104/102
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
STSU 250/23 230/400 2x115 250 96/104/102STSU 250/24 230/400 2x12 250 96/104/102STSU 250/48 230/400 2x24 250 96/104/102STSU 400/23 230/400 2x115 400 120/123/110STSU 400/24 230/400 2x12 400 120/123/110STSU 400/48 230/400 2x24 400 120/123/110STSU 630/23 230/400 2x115 630 150/150/112STSU 630/24 230/400 2x12 630 150/153/122STSU 630/48 230/400 2x24 630 150/150/112STSU 1000/23 230/400 2x115 1.000 150/150/156STSU 1000/24 230/400 2x12 1.000 150/190/174STSU 1000/48 230/400 2x24 1.000 150/150/156STSU 1600/23 230/400 2x115 1.600 192/185/161STSU 2000/23 230/400 2x115 2.000 192/185/183STSU 2500/23 230/400 2x115 2.500 192/185/189
Transformateurs Transformers1
20Sujet à modificationSubject to change
Transformateur de commandeControl transformerBUST
W J |
AVANTAGES BENEFITS
Prises côté primaire jusqu’à ±5 %permettant l’adaptation de la tension
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Hauteur de construction faible
Primary side ±5 % taps for voltageadjustment
Very good corrosion protection and lownoise due to vacuum impregnation
Low height
APPLICATIONS APPLICATIONS
Transformateur de commandepermettant une isolation électrique enentrée et en sortie.
Control transformer for the electricalisolation of the input and output sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 96.8 %, Indice de protection IP 00 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 96.8 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
BUST 1000/4/23 400 2x115 1.000 220/130/150BUST 1000/23/24 230 24 1.000 220/130/150BUST 1600/4/23 400 2x115 1.600 245/156/180BUST 1600/23/24 230 24 1.600 245/156/180BUST 2000/4/23 400 2x115 2.000 275/175/200BUST 2500/4/23 400 2x115 2.500 275/175/200BUST 3000/4/23 400 2x115 3.000 255/215/200BUST 3000/5/23 500 2x115 3.000 255/215/200BUST 3000/44/23 440 2x115 3.000 255/215/200BUST 4000/4/23 400 2x115 4.000 325/175/240BUST 4000/23/23 230 2x115 4.000 325/175/240BUST 4000/44/23 440 2x115 4.000 325/175/240BUST 5000/4/23 400 2x115 5.000 325/190/240BUST 5000/23/23 230 2x115 5.000 325/190/240BUST 6300/4/23 400 2x115 6.300 350/220/280BUST 6300/5/23 500 2x115 6.300 350/220/280BUST 6300/44/23 440 2x115 6.300 350/220/280BUST 8000/4/23 400 2x115 8.000 350/250/280BUST 10000/4/23 400 2x115 10.000 400/245/320
Transformateur de commandeControl power transformerCT
W / J
AVANTAGES BENEFITS
Versions à fusible disponibles
Versions avec rail DIN pourcomposants supplémentairesdisponibles
Manipulation 100 % sûre
Cavaliers inclus pour la sélection de latension primaire
Imprégné pour une protectionmaximum
Fused versions available
Versions with DIN rail for additionalcomponents available
100 % finger-safe
Jumpers included for primary voltageselection
Impregnated for max. protection
APPLICATIONS APPLICATIONS
Comme un transformateurd’alimentation pour isolementélectrique sûr les côtés d’entrée et desortie.
As a control power transformer foradjustment of the voltage and simpleelectrical isolation.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 95 %, Indice de protection IP 00 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 95 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
CT-005-048-12-x 2 x 240 120 50 66/92,7/80CT-005-048-24-x 2 x 240 24 50 66/92,7/80CT-005-060-12-x 600 120 50 66/92,7/80CT-005-060-24-x 600 24 50 66/92,7/80CT-007-048-12-x 2 x 240 120 75 78/102,7/79CT-007-048-24-x 2 x 240 24 75 78/102,7/79CT-007-060-12-x 600 120 75 78/102,7/79CT-007-060-24-x 600 24 75 78/102,7/79CT-010-048-12-x 2 x 240 120 100 78/102,7/82CT-010-048-24-x 2 x 240 24 100 78/102,7/82CT-010-060-12-x 600 120 100 78/102,7/82CT-010-060-24-x 600 24 100 78/102,7/78CT-015-048-12-x 2 x 240 120 150 96/117,7/100CT-015-048-24-x 2 x 240 24 150 96/117,7/100CT-015-060-12-x 600 120 150 96/117,7/100CT-015-060-24-x 600 24 150 96/117,7/100CT-020-048-12-x 2 x 240 120 200 96/117,7/108CT-020-048-24-x 2 x 240 24 200 96/117,7/108CT-020-060-12-x 600 120 200 96/117,7/108CT-020-060-24-x 600 24 200 96/117,7/108CT-025-048-12-x 2 x 240 120 250 96/117,7/122CT-025-048-24-x 2 x 240 24 250 96/117,7/122CT-025-060-12-x 600 120 250 96/117,7/122CT-025-060-24-x 600 24 250 96/117,7/122CT-030-048-12-x 2 x 240 120 300 120/137,7/104CT-030-048-24-x 2 x 240 24 300 120/137,7/104CT-030-060-12-x 600 120 300 120/137,7/104CT-030-060-24-x 600 24 300 120/137,7/104
Transformateurs Transformers 1
21Sujet à modification
Subject to change
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
CT-035-048-12-x 2 x 240 120 350 120/137,7/122CT-035-048-24-x 2 x 240 24 350 120/137,7/122CT-035-060-12-x 600 120 350 120/137,7/122CT-035-060-24-x 600 24 350 120/137,7/122CT-050-048-12-x 2 x 240 120 500 120/137,7/145CT-050-060-12-x 600 120 500 120/137,7/145CT-075-048-12-x 2 x 240 120 750 150/162,7/140CT-075-060-12-x 600 120 750 150/162,7/140CT-100-048-12-x 2 x 240 120 1000 174/183,2/145CT-100-060-12-x 600 120 1000 174/183,2/145CT-150-048-12-x 2 x 240 120 1500 192/198,2/165CT-150-060-12-x 600 120 1500 192/198,2/165CT-200-048-12-x 2 x 240 120 2000 192/202,4/180CT-200-060-12-x 600 120 2000 192/202,4/180CT-250-048-12-x 2 x 240 120 2500 192/202,4/190CT-250-060-12-x 600 120 2500 192/202,4/190
Transformateur FAIL-SAFEFAIL-SAFE transformerFST
w J 0 ¶ §
AVANTAGES BENEFITS
Avec une protection intégrée FAIL-SAFE
Puissance élevée pour unencombrement réduit grâce à undesign compact
Courant d’appel réduit
Peut être utilisé pour des fréquencesde 50 - 60 Hz
Excellente tenue à la corrosion et faiblebruit grâce à notre imprégnation sousvide
En entrée, pour des tensions de 230 Vet 400 V
Versions en 100 VA et 160 VA pourmontage sur fixation Rail DIN selonDIN 50022
With integrated FAIL-SAFE protection
High power density due to a compactconstruction design
Reduced inrush current
May be operated at 50 - 60 Hz
Very good corrosion protection and lownoise due to vacuum impregnation
Primary side for input voltage 230 Vand 400 V
100 VA and 160 VA versions formounting with integrated DIN railmounting in compliance with DIN50022
APPLICATIONS APPLICATIONS
Le transformateur FAIL-SAFE est untransformateur de commande pour unisolement électrique sûr entre l’entréeet la sortie.
Le transformateur FAIL-SAFE est untransformateur de séparation descircuits pour un isolement électriquesûr entre l’entrée et la sortie.
Le transformateur FAIL-SAFE est untransformateur de sécurité pour unisolement électrique sûr entre l’entréeet la sortie.
FAIL-SAFE transformer as controltransformer for electrical isolations ofthe input and output sides.
FAIL-SAFE transformer as an isolatingtransformer for the safe electricalisolation of the input and output sides.
FAIL-SAFE transformer as a safetytransformer to secure electricalisolation of the input and output sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Indice de protectionIP 00 Insulation class B, Max. ambient temperature 104 °F / 40 °C, Protectionindex IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
FST 100/23 230 / 400 230 100 84/94/83FST 100/24 230 / 400 24 100 84/94/83FST 160/23 230 / 400 230 160 96/102/102FST 160/24 230 / 400 24 160 96/102/102FST 250/23 230 / 400 230 250 105/112/106FST 250/24 230 / 400 24 250 105/112/106
Transformateurs Transformers1
x = -0: Sans fusible non-fused
-1: À fusible (hauteur + 16 mm / 0,63 po) fused (height + 16 mm / 0.63 in)
-2: Avec option de rail DIN pour composants supplémentaires with DIN rail option for additional components
22Sujet à modificationSubject to change
Transformateurs Transformers 1
23Sujet à modification
Subject to change
Transformateurs Transformers1
Aperçu des transformateurs d’isolement Overview isolating transformers
Outre notre service de livraison sous 24 h, découvrez notre gamme de produits standard. Pour plus d’informations, n’hésitez pas à consulter notre site block.eu.
In addition to our 24 hours BLOCK direct sales program an overview of the entire standard range. For more information see block.eu.
TypeType Tens
ion
nom
inal
e d’
entr
éeRa
ted
inpu
t vol
tage
Tens
ion
de s
ortie
nom
inal
eRa
ted
outp
ut v
olta
ge
Puis
sanc
ePo
wer
Tens
ion
d’ent
rée
doub
leDu
al in
put v
olta
ge
Anne
aux d
e le
vage
inté
grés
In
tegr
ated
cra
ne e
yes
Isol
atio
n ga
lvani
que
sécu
risée
Safe
gal
vani
c iso
latio
n
Plus
ieur
s di
men
sions
de
mon
tage
Mul
tiple
mou
ntin
g di
men
sions
Prot
ectio
n co
ntre
les
cour
ts-c
ircui
ts e
t les
su
rcha
rges
inté
grée
Isurc
harg
es in
tégr
éeIsu
rcha
rges
inté
grée
nteg
rate
d sh
ort-c
ircui
t and
ove
rload
pro
tect
ionsu
rcha
rges
inté
grée
nteg
rate
d sh
ort-c
ircui
t and
ove
rload
pro
tect
ionsu
rcha
rges
inté
grée
TT1219/230/241 V 24 V 1000 – 2500 VA r r rr r rr r r
380/400/420 V42 V 1600, 2500 VA r r rr r rr r r
2 x 115 V 1000 – 25000 VA r r rr r rr r r
TIM 230 V 2 x 115V 2 x 115 V 60 – 1000 VA r r r
ETTK 230 V 230 V 160 – 2500 VA r
TT3 3 x 400 V 3 x 400V 3 x 400 V ± 5 % 1000 – 30000 VA r r rr r rr r r
TT3 Neo 3 x 400 V 3 x 400V 3 x 400 V 10000 VA – 1 MVA r
TTMS 230 V 115/230 V 3150 – 8000 VA r rr r
SMTT 230 V 230 V 150 VA r r
ACT 230 V 24 V 10 – 100 VA r
SIM 230 V 2 x 12V 2 x 12 V 60 – 800 VA r r
EVKE 230 V 24 V 25 – 630 VA r
24Sujet à modificationSubject to change
Transformateur de commande, de sécurité et deséparation des circuitsControl- and safety isolating- resp. isolatingtransformerTT1
W J 2 " |
AVANTAGES BENEFITS
Isolation galvanique sécurisée
Technique de montage brevetée
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Prises côté primaire ±5 % permettantl’adaptation de la tension
Plusieurs dimensions de montage
Anneaux de levage intégrés
Safe galvanic isolation
Patented assembly technology
Very good corrosion protection and lownoise due to vacuum impregnation
Primary side ±5 % taps for voltageadjustment
Multiple mounting dimensions
Integrated crane eyes
APPLICATIONS APPLICATIONS
Comme un transformateur decommande pour un isolementélectrique sûr entre l’entrée et lasortie.
Comme un transformateur deséparation des circuits pour unisolement électrique sûr entre l’entréeet la sortie.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
As a control transformer for theelectrical isolation of the input andoutput sides.
Isolating transformer for the safeelectrical isolation of the input andoutput sides.
As a safety isolating transformer forthe safe electrical isolation of the inputand output sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation F, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 98 %, Indice de protection IP 00, IPXXB sur demande, En option, coffretsadaptés aux indices de protection les plus élevés Insulation class F, Maximumambient temperature 104 °F / 40 °C, Efficiency up to 98 %, Degree of protectionIP 00, IPXXB on request, Optionally adapted package for higher degrees ofprotection
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
TT1 1-4-23 380/400/420 2 x 115 1.000 150/220/125TT1 1-23-24 219/230/241 24 1.000 150/220/140TT1 1,6-4-23 380/400/420 2 x 115 1.600 160/230/145TT1 1,6-4-42 380/400/420 42 1.600 160/260/145TT1 1,6-23-24 219/230/241 24 1.600 160/265/145TT1 2-4-23 380/400/420 2 x 115 2.000 175/245/140TT1 2-23-24 219/230/241 24 2.000 175/285/140TT1 2,5-4-23 380/400/420 2 x 115 2.500 200/275/155TT1 2,5-4-42 380/400/420 42 2.500 200/310/155TT1 2,5-23-24 219/230/241 24 2.500 200/315/155TT1 3-4-23 380/400/420 2 x 115 3.000 200/275/165TT1 3-5-23 475/500/525 2 x 115 3.000 200/275/165TT1 3-44-23 418/440/462 2 x 115 3.000 200/275/165TT1 4-4-23 380/400/420 2 x 115 4.000 240/335/165
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
TT1 4-5-23 475/500/525 2 x 115 4.000 240/335/165TT1 4-44-23 418/440/462 2 x 115 4.000 240/335/165TT1 5-4-23 380/400/420 2 x 115 5.000 240/335/165TT1 5-5-23 475/500/525 2 x 115 5.000 240/335/195TT1 5-44-23 418/440/462 2 x 115 5.000 240/335/195TT1 6,3-4-23 380/400/420 2 x 115 6.300 240/335/210TT1 6,3-5-23 475/500/525 2 x 115 6.300 240/335/210TT1 6,3-44-23 418/440/462 2 x 115 6.300 240/335/210TT1 8-4-23 380/400/420 2 x 115 8.000 280/385/215TT1 8-5-23 475/500/525 2 x 115 8.000 280/385/215TT1 8-44-23 418/440/462 2 x 115 8.000 280/385/215TT1 10-4-23 380/400/420 2 x 115 10.000 280/385/230TT1 10-5-23 475/500/525 2 x 115 10.000 280/385/230TT1 10-44-23 418/440/462 2 x 115 10.000 280/385/230TT1 12,5-4-23 380/400/420 2 x 115 12.500 320/460/250TT1 15-4-23 380/400/420 2 x 115 15.000 320/470/250TT1 20-4-23 380/400/420 2 x 115 20.000 320/470/280TT1 25-4-23 380/400/420 2 x 115 25.000 320/490/310
Transformateurs Transformers 1
Tensions nominales différentes sur demande. Different voltage ratings on request.
25Sujet à modification
Subject to change
Transformateur de séparation des circuitsIsolating transformerTIM
w J !
AVANTAGES BENEFITS
Isolation galvanique sécurisée
Protection intégrée contre les courts-circuits et les surcharges
Tension de sortie double pour lacommutation en série ou en parallèle
Très bonne protection contre l’humiditéet faible développement du bruit grâceau scellement intégral à la résine decoulée XtraDenseFill (jusqu’à 300 VA)
Bornes de connexion à vis sous lecouvercle avec capacité de traction
Safe galvanic isolation
Integrated short-circuit and overloadprotection
Double output voltage for series orparallel connection
Very good moisture protection andlow noise due to XtraDenseFill resinencapsulation (up to 300 VA)
Screw terminals under cover withstrain relief
APPLICATIONS APPLICATIONS
Transformateur d’isolementpermettant une isolation électriquesécurisée en entrée et en sortie
Isolating transformer for the safeelectrical isolation of the input andoutput sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation A ou B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 95 %, Indice de protection IP 20 Insulation class A or B, Maximumambient temperature 104 °F / 40 °C, Efficiency up to 95 %, Degree of protectionIP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
TIM 60 230 2 x 115 60 77/90/166TIM 100 230 2 x 115 100 77/90/166TIM 200 230 2 x 115 200 117/97/223TIM 300 230 2 x 115 300 117/97/223TIM 500 230 2 x 115 500 176/176/283TIM 800 230 2 x 115 800 200/166/283TIM 1000 230 2 x 115 1000 200/166/283
Transformateur de séparation des circuitsIsolating transformerETTK
J
AVANTAGES BENEFITS
Isolation galvanique sécurisée
Protection intégrée contre les courts-circuits et les surcharges
Très bonne protection contre l’humiditéet faible développement du bruit grâceau scellement intégral à la résine decoulée
Indice de protection élevé
Poignée de transport, câbles deconnexion réseau et prise de sûretépour une utilisation mobile
Safe galvanic isolation
Integrated short-circuit and overloadprotection
Very good moisture protection and lownoise due to resin encapsulation
High degree of protection
Carry handle, mains cable with safetyplug, shockproof socket for portableapplication
APPLICATIONS APPLICATIONS
Transformateur d’isolementpermettant une isolation électriquesécurisée en entrée et en sortie.
Isolating transformer for the safeelectrical isolation of the input andoutput sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation A, Température ambiante de 40 °C max., Indice de protectionIP 67 Insulation class A, Maximum ambient temperature 104 °F / 40 °C, Degreeof protection IP 67
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
ETTK 160 230 230 160 105/160/170ETTK 250 230 230 250 120/185/200ETTK 630 230 230 630 120/230/300ETTK 1000 230 230 1000 140/230/300ETTK 1600 230 230 1600 170/225/340ETTK 2500 230 230 2500 170/225/340
Transformateurs Transformers1
26Sujet à modificationSubject to change
Transformateur de séparation des circuitsIsolating transformerTT3
W J "
AVANTAGES BENEFITS
Isolation galvanique sécurisée
Technique de montage brevetée pourréduire les pertes de chaleur
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Prises côté secondaire ±5 %permettant l’adaptation de la tension
Plusieurs dimensions de montage
Rail de fixation élargi pour faciliter lemontage par le haut
Anneaux de levage intégrés
Safe galvanic isolation
Patented assembly technology to lowerheat losses
Very good corrosion protection and lownoise due to vacuum impregnation
Secondary side ±5 % taps for voltageadjustment
Multiple mounting dimensions
Enlarged fixing rail for easy installationfrom above
Integrated lifting brackets
APPLICATIONS APPLICATIONS
Transformateur d’isolementpermettant une isolation électriquesécurisée en entrée et en sortie
Isolating transformer for the safeelectrical isolation of the input andoutput sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation F, Température ambiante de 50 °C max., Degré d’efficacitéjusqu’à 97.5 %, Indice de protection IP 00 ou IP 23, En option, coffret adapté à desindices de protection élevés Insulation class F, Maximum ambient temperature122 °F / 50 °C, Efficiency up to 97.5 %, Degree of protection IP 00 or IP 23,Optionally adapted package for higher degrees of protection
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
TT3 1-4-4 3 x 400 3 x 400 1000 267/215/125TT3 2,5-4-4 3 x 400 3 x 400 2500 315/250/165TT3 5-4-4 3 x 400 3 x 400 5000 410/355/155TT3 6,3-4-4 3 x 400 3 x 400 6300 410/360/175TT3 8-4-4 3 x 400 3 x 400 8000 410/360/180TT3 10-4-4 3 x 400 3 x 400 10000 480/400/192TT3 12,5-4-4 3 x 400 3 x 400 12.500 480/400/222TT3 16-4-4 3 x 400 3 x 400 16000 550/510/267TT3 20-4-4 3 x 400 3 x 400 20000 550/510/297TT3 25-4-4 3 x 400 3 x 400 25000 550/510/297TT3 30-4-4 3 x 400 3 x 400 30000 550/480/320
Transformateur de séparation des circuitsIsolating transformerTT3 Neo
W "
AVANTAGES BENEFITS
Isolation galvanique sécurisée
Très bonne dissipation des pertesthermiques grâce à des canaux derefroidissement disposés idéalementdans les bobinages
Anneaux de levage intégrés
Safe galvanic isolation
Very good discharging of thermallosses by means of optimally arrangedcooling channels within the coils
Integrated lifting brackets
APPLICATIONS APPLICATIONS
Transformateur d’isolementpermettant une isolation électriquesécurisée en entrée et en sortie
Isolating transformer for the safeelectrical isolation of the input andoutput sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation F, Température ambiante de 40 °C max., Indice de protection IP00 Insulation class F, Maximum ambient temperature 104 °F / 40 °C, Degree ofprotection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
TT3-A010-4040-0 3 x 400 3 x 400 10.000 482/400/230TT3-A016-4040-0 3 x 400 3 x 400 16.000 552/460/270TT3-A020-4040-0 3 x 400 3 x 400 20.000 552/460/300TT3-A025-4040-0 3 x 400 3 x 400 25.000 552/460/300TT3-A030-4040-0 3 x 400 3 x 400 30.000 552/460/300TT3-A040-4040-0 3 x 400 3 x 400 40.000 550/550/300TT3-A050-4040-0 3 x 400 3 x 400 50.000 620/570/350TT3-A063-4040-0 3 x 400 3 x 400 63.000 620/570/380TT3-A080-4040-0 3 x 400 3 x 400 80.000 740/790/340TT3-A100-4040-0 3 x 400 3 x 400 100.000 740/790/370TT3-A125-4040-0 3 x 400 3 x 400 125.000 740/805/400TT3-A160-4040-0 3 x 400 3 x 400 160.000 890/985/360TT3-A200-4040-0 3 x 400 3 x 400 200.000 890/920/470TT3-A250-4040-0 3 x 400 3 x 400 250.000 1000/1040/530TT3-A315-4040-0 3 x 400 3 x 400 315.000 1000/1040/555TT3-A400-4040-0 3 x 400 3 x 400 400.000 1075/1100/580TT3-A500-4040-0 3 x 400 3 x 400 500.000 1075/1100/630TT3-A630-4040-0 3 x 400 3 x 400 630.000 1075/1100/710TT3-A800-4040-0 3 x 400 3 x 400 800.000 1160/1120/730TT3C1000-4040-0 3 x 400 3 x 400 1.000.000 1160/1120/730
Transformateurs Transformers 1
Pour d’autres niveaux de tension/puissance ou pour connaître les coffrets adaptés, veuillez consulter le site block.eu. Other voltages/power levels or suitable enclosures please check block.eu.
Pour connaître les coffrets adaptés, veuillez consulter le site block.eu. Différentes tensions nominales sur demande. For suitable enclosures please check block.eu. Different voltage ratings on request.
27Sujet à modification
Subject to change
Transformateur de séparation des circuits médicalIsolating transformer for supply of medical roomsTTMS
J ¿
AVANTAGES BENEFITS
Isolation galvanique sécurisée
Résistance CPT intégrée dans chaquebobine permettant l’établissementd’une unité de surveillance externepour la protection contre lessurcharges
Courant d’appel réduit
Degré d’efficacité très élevé
Tension de court-circuit très faible
Courant de fonctionnement à vide trèsfaible
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Fixation simplifiée à l’aide d’un rail defixation métallique robuste muni de8 orifices oblongs
Safe galvanic isolation
PTC resistor built into every coil toset up an external monitoring unit forprotection against overload
Reduced inrush current
High efficiency
Low short-circuit voltage
Very low idle current
Very good corrosion protection and lownoise due to vacuum impregnation
Simple mounting due to robust metalfixing rail with 8 oval slots
APPLICATIONS APPLICATIONS
Transformateurs de séparationdes circuits pour la fourniture enénergie des locaux médicaux, grouped’utilisateurs 2.
Isolating transformer for supply ofmedical rooms of the user group 2.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 97 %, Indice de protection IP 00, Boîtier adapté aux types de protection lesplus élevés en option Insulation class B, Maximum ambient temperature 104 °F /40 °C , Efficiency up to 97 %, Degree of protection IP 00, Optionally adaptedpackage for higher degrees of protection
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
TTMS 3150/230 230 115/230 3.150 260/345/195TTMS 4000/230 230 115/230 4.000 310/395/190TTMS 5000/230 230 115/230 5.000 310/395/200TTMS 6300/230 230 115/230 6.300 310/395/215TTMS 8000/230 230 115/230 8.000 310/395/230
Transformateur anti-parasitesInterference suppressing isolating transformerSMTT
J
AVANTAGES BENEFITS
Isolation galvanique sécurisée
Courant de fuite faible et résistanced’isolation élevée
Bonnes propriétés d’atténuation contreles parasites à haute fréquence et lesimpulsions
Champ de dispersion magnétiquerestreint de 50 Hz
Protection intégrée contre les courts-circuits et les surcharges
Très bonne protection contre l’humiditéet faible développement du bruit grâceau scellement intégral à la résine decoulée XtraDenseFill
Indice de protection élevé
Poignée de transport, câbles deconnexion réseau et prise de sûretépour une utilisation mobile
Safe galvanic isolation
Low leakage current and high insulationresistance
Good attenuation against radiofrequency interference and pulses
Low magnetic 50 Hz leakage field
Integrated short-circuit and overloadprotection
Very good moisture protection andlow noise due to XtraDenseFill resinencapsulation
High degree of protection
Carry handle, mains cable with safetyplug, shockproof socket for portableapplication
APPLICATIONS APPLICATIONS
Transformateur d’isolement pourune utilisation mobile, permettant deminimiser des perturbations sur leréseau tels que des parasites ou dubruit électrique.
Isolating transformer for portableapplication to minimize mains supplyfaults such as disturbing pulses andelectrical noise.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation A, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 90 %, Indice de protection IP 40 Insulation class A, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 90 %, Degree of protection IP 40
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
SMTT 150 230 230 150 93,5/160/180
Transformateurs Transformers1
28Sujet à modificationSubject to change
Transformateur de sécuritéSafety isolating transformerACT
J 1
AVANTAGES BENEFITS
Protection intégrée contre les courts-circuits et les surcharges grâce auprotecteur thermique en entrée etau coupe-circuit à fusible en sortie(pour l’ACT 10, uniquement protecteurthermique en entrée)
Protection durable contre lacorrosion, valeur d’isolation élevée etfiabilité électrique la plus élevée parencapsulation intégrale avec notrerésine XtraDenseFill
Boîtier en plastique stable pour unmontage sur rail DIN, par exemple,dans les coffrets de distribution outableaux de comptage
Integrated short-circuit and overloadprotection due to temperature fusein the input and fuse in the output(ACT 10 only temperature fuse)
Permanent corrosion protection, highinsulation value and maximum electricalreliability due to XtraDenseFill resinencapsulation
Robust plastic housing for DIN railmounting, e.g. in consumer units ormeter mounting boards
APPLICATIONS APPLICATIONS
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
Safety isolating transformer for thesafe electrical isolation of the input andoutput sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 25 °C max., Indice de protectionIP 00 Insulation class B, Maximum ambient temperature 77 °F / 25 °C, Degreeof protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
ACT 10 230 24 10 94/63/35ACT 25 230 24 25 94/63/106ACT 63 230 24 63 94/63/159ACT 100 230 24 100 94/63/159
Transformateur de sécuritéSafety isolating transformerSIM
w J 1
AVANTAGES BENEFITS
Protection intégrée contre les courts-circuits et les surcharges
Tension de sortie double pour lacommutation en série ou en parallèle
Très bonne protection contre l’humiditéet faible développement du bruit grâceà l'encapsulation intégrale avec notrerésine XtraDenseFill (jusqu’à 300 VA)
Bornes de connexion à vis sous lecouvercle avec capacité de traction
Integrated short-circuit and overloadprotection
Dual output voltage for series orparallel connection
Very good moisture protection andlow noise due to XtraDenseFill resinencapsulation (up to 300 VA)
Screw terminals under cover withstrain relief
APPLICATIONS APPLICATIONS
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
Safety isolating transformer for thesafe electrical isolation of the input andoutput sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation A, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 95 %, Indice de protection IP 20 Insulation class A, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 95 %, Degree of protection IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
SIM 60 230 2 x 12 60 166/76/77SIM 100 230 2 x 12 100 166/76/77SIM 200 230 2 x 12 200 223/97/117SIM 300 230 2 x 12 300 117/228/117SIM 500 230 2 x 12 500 200/166/283SIM 800 230 2 x 12 800 200/166/283
Transformateurs Transformers 1
29Sujet à modification
Subject to change
Transformateur de sécuritéSafety isolating transformerEVKE
J 1 O
AVANTAGES BENEFITS
Protection intégrée contre les courts-circuits et les surcharges
Très bonne protection contre l’humiditéet faible développement du bruit grâceà l'encapsulation intégrale avec notrerésine
Indice de protection élevé
Raccords filetés en plastique sur lesbornes
Integrated short-circuit and overloadprotection
Very good moisture protection and lownoise due to resin encapsulation
High degree of protection
Plastic fittings on terminals
APPLICATIONS APPLICATIONS
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
Safety isolating transformer for thesafe electrical isolation of the input andoutput sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation E, Température ambiante de 40 °C max., Indice de protectionIP 68 Insulation class E, Maximum ambient temperature 104 °F / 40 °C, Degreeof protection IP 68
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
EVKE 25/24 230 24 25 95/72/115EVKE 40/24 230 24 40 120/78/150EVKE 100/24 230 24 100 145/90/180EVKE 160/24 230 24 160 150/105/190EVKE 250/24 230 24 250 150/105/190EVKE 400/24 230 24 400 195/130/255EVKE 630/24 230 24 630 215/150/280
AVANTAGES BENEFITS
APPLICATIONS APPLICATIONS
DONNÉES TECHNIQUES TECHNICAL DATA
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage
Power VA DimensionsW/H/D in mm
Transformateurs Transformers1
30Sujet à modificationSubject to change
Transformateurs Transformers 1
31Sujet à modification
Subject to change
TypeType Tens
ion
nom
inal
e d’
entr
éeRa
ted
inpu
t vol
tage
Tens
ion
de s
ortie
nom
inal
eRa
ted
outp
ut v
olta
ge
Inte
nsité
de
sort
ieOu
tput
cur
rent
Degr
é d’e
ffica
cité
très
éle
véVe
ry h
igh
effic
ienc
y
Poid
s et
enc
ombr
emen
t fai
bles
Low
wei
ght a
nd s
mal
l size
Mon
tage
sim
ple
Sim
ple
mou
ntin
g
Prot
ectio
n co
ntre
les
cour
ts-c
ircui
ts e
t les
su
rcha
rges
inté
grée
Inte
grat
ed s
hort
-circ
uit a
nd o
verlo
ad p
rote
ction
surc
harg
es in
tégr
éeIn
tegr
ated
sho
rt-c
ircui
t and
ove
rload
pro
tect
ionsu
rcha
rges
inté
grée
AIM115 V 220, 230, 240 V 0.8 – 8.0 A r rr r r
115 V 115 V 1.6 – 16.0 A r rr r r
220, 230, 240 V 115, 220, 230, 240 V 1.6 – 16.0 A r rr r r
ESP230 V 80/115/130/150/170/190 V 1.5 – 18.00 A r r rr r rr r r
400 V 140/170/200/235/270/310 V 0.8 – 10.0 A r r rr r rr r r
Aperçu des autotransformateurs Overview autotransformers
TypeType Tens
ion
nom
inal
e d’
entr
éeRa
ted
inpu
t vol
tage
Tens
ion
de s
ortie
nom
inal
eRa
ted
outp
ut v
olta
ge
Puis
sanc
ePo
wer
Degr
é d’e
ffica
cité
éle
véHi
gh e
fficie
ncy
Anne
aux d
e le
vage
inté
grés
In
tegr
ated
cra
ne e
yes
Plus
ieur
s di
men
sions
de
mon
tage
Mul
tiple
mou
ntin
g di
men
sions
Prot
ectio
n co
ntre
les
cour
ts-c
ircui
ts e
t les
su
rcha
rges
inté
grée
Inte
grat
ed s
hort
-circ
uit a
nd o
verlo
ad p
rote
ction
surc
harg
es in
tégr
éeIn
tegr
ated
sho
rt-c
ircui
t and
ove
rload
pro
tect
ionsu
rcha
rges
inté
grée
Poid
s et
enc
ombr
emen
t fai
bles
Low
wei
ght a
nd s
mal
l size
E-JET 230 V 110V 110 V 250 – 1000 VA r r
JET 110 V 230V 230 V 250 – 1000 VA r r
AT3 3 x 200/208 - 3 x 690 V 3 x 400V 3 x 400 V 2000 – 250000 VA r r rr r rr r r r
Outre notre service de livraison sous 24 h, découvrez notre gamme de produits standard. Pour plus d’informations, n’hésitez pas à consulter notre site block.eu.
In addition to our 24 hours BLOCK direct sales program an overview of the entire standard range. For more information see block.eu.
Transformateurs Transformers1
32Sujet à modificationSubject to change
AutotransformateurAutotransformerAIM
J t
AVANTAGES BENEFITS
Poids et encombrement faibles(contrairement aux transformateursd’isolement)
Protection intégrée contre les courts-circuits et les surcharges
Degré d’efficacité très élevé
Très bonne protection contre l’humiditéet faible développement du bruit grâceà l'encapsulation intégrale avec notrerésine de coulée XtraDenseFill (AIM1,8/8 - AIM 5,0/2,5)
Bornes de connexion à vis sous lecouvercle avec capacité de traction
Low weight and small size(compared to isolating transformers)
Integrated short-circuit and overloadprotection
High efficiency
Very good moisture protectionand low noise due toXtraDenseFill resin encapsulation(AIM 1.8/8 - AIM 5.0/2.5)
Screw terminals under cover withstrain relief
APPLICATIONS APPLICATIONS
Autotransformateur permettantl’adaptation de la tension en entrée eten sortie sans nécessiter d’isolationélectrique
Autotransformer for easy step-up/step-down without isolation
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation A ou B, Température ambiante de 40 °C max., Indice deprotection IP 20 Insulation class A or B, Maximum ambient temperature104 °F / 40 °C, Degree of protection IP 20
Désignation duproduitN° deréférence
Tensiond'entrée Vac
Tensionde sortie Vac
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
OutputCurrent A
DimensionsW/H/D in mm
AIM 1,6/0,8 115/220/230/240
115/ 220/ 230/ 240 0,80 (PRI 115 /SEC 220, 230, 240 V);1,60 (PRI 115 V / SEC115 );1,60(PRI 220,230, 240 V / SEC 115,220, 230, 240 )
77/76/166
AIM 3,2/1,6 115/220/230/240
115/ 220/ 230/ 240 1,60 (PRI 115 /SEC 220, 230, 240);3,20 (PRI 115 / SEC115);3,20(PRI 220, 230,240 / SEC 115, 220,230, 240)
117/97/223
AIM 5,0/2,5 115/220/230/240
115/ 220/ 230/ 240 2,50 (PRI 115 /SEC 220, 230, 240);5,00 (PRI 115 / SEC115); 5,00 (PRI 220,230, 240 / SEC 115,220, 230, 240)
117/117/223
Désignation duproduitN° deréférence
Tensiond'entrée Vac
Tensionde sortie Vac
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
OutputCurrent A
DimensionsW/H/D in mm
AIM 10/5 115/220/230/240
115/ 220/ 230/ 240 5,00 (PRI 115 /SEC 220, 230, 240);10,00 (PRI 115 / SEC115 ); 10,00 (PRI 220,230, 240 / SEC 115,220, 230, 240 )
200/166/283
AIM 16/8 115/220/230/240
115/ 220/ 230/ 240 8,00 (PRI 115 /SEC 220, 230, 240);16,00 (PRI 115 / SEC115); 16,00 (PRI 220,230, 240 / SEC 115,220, 230, 240)
200/165/283
Transformateurs Transformers 1
33Sujet à modification
Subject to change
AutotransformateurAutotransformerESP
J ?
AVANTAGES BENEFITS
Poids et encombrement faibles(contrairement aux transformateursd’isolement)
Degré d’efficacité très élevé
Très bonne protection contre l’humiditéet faible développement du bruit grâceà l’imprégnation sous vide
Fixation simplifiée à l’aide d’une semellemétallique robuste munie d’orificesoblongs
Low weight and small size (comparedto isolating transformers)
High efficiency
Very good moisture protection and lownoise due to vacuum impregnation
Simple mounting due to robust metalfootplate with oval slots
APPLICATIONS APPLICATIONS
Autotransformateur, par exemple, pourcontrôler la vitesse du moteur d'unventilateur monophasé.
One example, autotransformer forsetting the speed of single-phase fanmotors.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Indice de protectionIP 00 Insulation class B, Maximum ambient temperature 104 °F / 40 °C, Degreeof protection IP 00
Désignation duproduitN° deréférence
Tensiond'entrée Vac
Tensionde sortie Vac
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
OutputCurrent A
DimensionsW/H/D in mm
ESP 230/1,5 230 80/115/130/150/170/190
1,50 75/100/84
ESP 230/2,8 230 80/115/130/150/170/190
2,80 85/118/105
ESP 230/5,8 230 80/115/130/150/170/190
5,80 91/130/120
ESP 230/10 230 80/115/130/150/170/190
10,00 112/135/150
ESP 230/18 230 80/115/130/150/170/190
18,00 120/150/174
ESP 400/0,8 400 140/170/200/235/270/310
0,80 75/100/84
ESP 400/1,6 400 140/170/200/235/270/310
1,60 85/118/105
ESP 400/3,6 400 140/170/200/235/270/310
3,60 91/130/120
ESP 400/5,4 400 140/170/200/235/270/310
5,40 112/135/150
ESP 400/10 400 140/170/200/235/270/310
10,00 120/150/174
AutotransformateurAutotransformerE-JET
J t
AVANTAGES BENEFITS
Surveillance électronique du potentieluniquement par la commutationde la tension de sortie, lorsque lafiche de contact de protection estcorrectement branchée
Protection intégrée contre les courts-circuits et les surcharges
Degré d’efficacité très élevé
Très bonne protection contre l’humiditéet faible développement du bruit grâceà l'encapsulation intégrale avec notrerésine XtraDenseFill
Poignée de transport, câble deconnexion réseau avec fiche desécurité, prise NEMA5-15 (États-Unis)pour une utilisation mobile
Electronic potential monitoring by notconnecting the output voltage untilthe protected contact plug is insertedcorrectly
Integrated short-circuit and overloadprotection
Very high efficiency
Very good moisture protection andlow noise due to XtraDenseFill resinencapsulation
Carry handle, mains cable with safetyplug, socket NEMA5-15 (USA) forportable application
APPLICATIONS APPLICATIONS
Autotransformateur pour uneutilisation mobile permettantl’adaptation de la tension de réseaux230 V sur des appareils 110 Vlorsqu’aucune isolation électrique n’estnécessaire.
Autotransformer for portableapplication for the adjustment of thevoltage in 230 V networks to 110 Vequipment when no electrical isolationis required.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation A, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 96 %, Indice de protection IP 22 Insulation class A, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 96 %, Degree of protection IP 22
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
E-JET 250 230 110 250 95/155/160E-JET 500 230 110 500 126/192/180E-JET 1000 230 110 1.000 143/197/244
Transformateurs Transformers1
34Sujet à modificationSubject to change
AutotransformateurAutotransformerJET
J t
AVANTAGES BENEFITS
Protection intégrée contre les courts-circuits et les surcharges
Degré d’efficacité très élevé
Très bonne protection contre l’humiditéet faible développement du bruit àl'encapsulation avec notre résine decoulée XtraDenseFill
Poignée de transport, câble deconnexion réseau NEMA5-15 (États-Unis) et prise pour une utilisationmobile
Integrated short-circuit and overloadprotection
High efficiency
Very good moisture protection andlow noise due to XtraDenseFill resinencapsulation
Carrying handle, mains connectinglead NEMA5-15 (USA) and socket forportable application
APPLICATIONS APPLICATIONS
Autotransformateur pour uneutilisation mobile permettantl’adaptation de la tension de réseaux110 V sur des appareils 230 Vlorsqu’aucune isolation électrique n’estnécessaire.
Autotransformer for portableapplication for the adjustment ofthe voltage in 110 Vac networks to230 Vac equipment when no electricalisolation is required.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation A, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 96 %, Indice de protection IP 22 Insulation class A, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 96 %, Degree of protection IP 22
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
JET 250 110 230 250 95/155/160JET 500 110 230 500 126/192/180JET 1000 110 230 1.000 143/197/244
AutotransformateurAutotransformerAT3
W J ?
AVANTAGES BENEFITS
Poids et encombrement faibles(comparés aux transformateursd’isolement)
Degré d’efficacité très élevé
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Plusieurs dimensions de montage
Rail de fixation élargi pour faciliter lemontage par le haut
Anneaux de levage intégrés
Low weight and small size (comparedto isolating transformers)
High efficiency
Very good corrosion protection and lownoise due to vacuum impregnation
Multiple mounting dimensions
Enlarged fixing rail for easy installationfrom above
Integrated lifting brackets
APPLICATIONS APPLICATIONS
Autotransformateur permettantl’adaptation de la tension en entrée eten sortie sans nécessiter d’isolationélectrique.
Autotransformer for adjustment ofthe voltage on the input and outputsides with no requirement for electricalisolation.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation F, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 98 %, Indice de protection IP 00, En option, coffret adapté à des indicesde protection élevés Insulation class F, Maximum ambient temperature 104 °F /40 °C, Efficiency up to 98 %, Degree of protection IP 00, Optionally adaptedpackage for higher degrees of protection
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
AT3 2-20/21-4 3 x 200/208 3 x 400 2.000 220/175/125AT3 2-22/23-4 3 x 220/230 3 x 400 2.000 220/175/125AT3 2-44/46-4 3 x 440/460 3 x 400 2.000 155/155/95AT3 2-48/50-4 3 x 480/500 3 x 400 2.000 155/155/110AT3 2-58/60-4 3 x 575/600 3 x 400 2.000 220/175/105AT3 3,5-20/21-4 3 x 200/208 3 x 400 3.500 267/220/150AT3 3,5-22/23-4 3 x 220/230 3 x 400 3.500 267/220/149AT3 3,5-24/35-4 3 x 240/346 3 x 400 3.500 267/215/125AT3 3,5-38/42-4 3 x 380/415 3 x 400 3.500 155/155/95AT3 3,5-44/46-4 3 x 440/460 3 x 400 3.500 155/155/110AT3 3,5-48/50-4 3 x 480/500 3 x 400 3.500 220/175/115AT3 3,5-58/60-4 3 x 575/600 3 x 400 3.500 267/215/125AT3 3,5-69-4 3 x 600/690 3 x 400 3.500 267/215/125AT3 10-20/21-4 3 x 200/208 3 x 400 10.000 352/280/190AT3 10-22/23-4 3 x 220/230 3 x 400 10.000 352/280/190AT3 10-38/42-4 3 x 380/415 3 x 400 10.000 220/175/105AT3 10-44/46-4 3 x 440/460 3 x 400 10.000 267/215/125AT3 10-48/50-4 3 x 480/500 3 x 400 10.000 267/220/150AT3 10-58/60-4 3 x 575/600 3 x 400 10.000 315/250/165AT3 10-69-4 3 x 600/690 3 x 400 10.000 350/280/162
Transformateurs Transformers 1
35Sujet à modification
Subject to change
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
AT3 15-20/21-4 3 x 200/208 3 x 400 15.000 412/380/180AT3 15-22/23-4 3 x 220/230 3 x 400 15.000 410/345/195AT3 15-24/35-4 3 x 240/346 3 x 400 15.000 410/345/175AT3 15-38/42-4 3 x 380/415 3 x 400 15.000 220/175/125AT3 15-44/46-4 3 x 440/460 3 x 400 15.000 267/215/149AT3 15-58/60-4 3 x 575/600 3 x 400 15.000 350/280/177AT3 25-20/21-4 3 x 200/208 3 x 400 25.000 480/440/220AT3 25-22/23-4 3 x 220/230 3 x 400 25.000 480/440/220AT3 25-44/46-4 3 x 440/460 3 x 400 25.000 315/255/185AT3 25-48/50-4 3 x 480/500 3 x 400 25.000 352/280/190AT3 25-58/60-4 3 x 575/600 3 x 400 25.000 480/395/182AT3 45-20/21-4 3 x 200/208 3 x 400 45.000 550/510/290AT3 45-22/23-4 3 x 220/230 3 x 400 45.000 550/510/260AT3 45-44/46-4 3 x 440/460 3 x 400 45.000 410/380/155AT3 45-48/50-4 3 x 480/500 3 x 400 45.000 480/425/170AT3 70-44/46-4 3 x 440/460 3 x 400 70.000 480/440/195AT3 70-48/50-4 3 x 480/500 3 x 400 70.000 550/485/240
Transformateur variableVariable transformerESS
J t
AVANTAGES BENEFITS
Réglage continu de la tensionalternative de zéro à la valeur maximale
Nettoyage automatique des pistes decontact détachées
Montage sur semelle à 4 points
Boutons de réglage et cadransdisponibles en option
Stepless adjustment of the AC voltagefrom zero to the maximum value
Self-cleaning of the exposed contacttracks
4-point flange mounting
Rotary knobs and scales optionallyavailable
APPLICATIONS APPLICATIONS
Autotransformateur variable rotatifpour le réglage en continu de tensionsou des courants sous charge.
Variable auto transformer forcontinuous adjustment of AC voltagesor currents under load.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 45 °C max., Indice de protectionIP 00 Insulation class B, Maximum ambient temperature 113 °F / 45 °C, Degreeof protection IP 00
Désignation duproduitN° deréférence
Tensiond'entrée Vac
Tensionde sortie Vac
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
OutputCurrent A
DimensionsW/H/D in mm
ESS 102 230 0...230/250 2,00 116/125/137ESS 103 230 0...230/250 3,15 116/147/159ESS 104 230 0...230/250 4,00 116/147/159ESS 106 230 0...230/250 6,30 135/147/159ESS 110 230 0...230/250 10,00 150/185/197ESS 118 230 0...230/250 18,00 153/231/243ESS 302 230 0...230/260 1,80 116/125/137ESS 303 230 0...230/260 3,15 116/147/159ESS 305 230 0...230/260 5,00 135/147/159ESS 308 230 0...230/260 8,00 150/185/197ESS 318 230 0...230/260 18,00 153/231/243ESS 9008 230 0...230 0,80 98/87/94,5ESS 9013 230 0...230 1,25 98/87/94,5
Transformateurs Transformers1
Pour d’autres niveaux de tension/puissance ou pour connaître les coffrets adaptés, veuillez consulter le site block.eu. Other voltages/power levels or suitable enclosures please check block.eu.
36Sujet à modificationSubject to change
37Sujet à modification
Subject to change
Transformateurs Transformers1
TypeType Tens
ion
nom
inal
e d’
entr
éeRa
ted
inpu
t vol
tage
Tens
ion
de s
ortie
nom
inal
eRa
ted
outp
ut v
olta
ge
Puis
sanc
ePo
wer
Taille
min
imal
e av
ec u
ne p
uiss
ance
éle
vée
Min
imum
size
at h
igh
pow
er
Tens
ion
d’ent
rée
doub
leDu
al in
put v
olta
ge
Tens
ion
de s
ortie
dou
ble
Dual
outp
ut v
olta
ge
Pert
es à
vid
e m
inim
ales
Mini
mal
no-lo
ad lo
sses
RKD 2 x 115 V
2 x 12 V 15 – 300 VA r rr r r
2 x 15 V 15 – 225 VA r rr r r
2 x 18 V 15 – 400 VA r rr r r
2 x 24 V 20 – 500 VA r rr r r
2 x 30 V 250 – 625 VA r rr r r
2 x 35 V 500 VA r rr r r
2 x 40 V 800 VA r rr r r
2 x 50 V 1000 VA r rr r r
2 x 115 V 625 – 3000 VA r rr r r
RTE 230 V
2 x 12 V 15 – 250 VA r r rr r
2 x 15 V 15 – 225 VA r r rr r
2 x 18 V 15 – 400V 15 – 400 VA r r rr r
2 x 24 V 20 – 500V 20 – 500 VA r r rr r
2 x 30 V 250 – 625V 250 – 625 VA r r rr r
2 x 35 V 500 VA r r rr r
Aperçu des transformateurs toriques Overview toroidal transformers
Outre notre service de livraison sous 24 h, découvrez notre gamme de produits standard. Pour plus d’informations, n’hésitez pas à consulter notre site block.eu.
In addition to our 24 hours BLOCK direct sales program an overview of the entire standard range. For more information see block.eu.
38Sujet à modificationSubject to change
Transformateur torique et transformateur d’isolementToroidal safety isolating and isolating transformerRKD
W / J 2 "
AVANTAGES BENEFITS
Encombrement réduit pour despuissances élevées
Poids réduit
Tension d’entrée double pour laconnexion en série ou en parallèle
Pertes à vide minimales
Comportement thermique excellentgrâce à un champ de dispersionmagnétique réduit
Minimum size at high power
Low weight
Dual input voltage for series or parallelconnection
Minimal no-load losses
Outstanding temperature behavior dueto low magnetic leakage field
APPLICATIONS APPLICATIONS
**Comme un transformateurd’alimentation pour un isolementélectrique sûr entre l’entrée et lasortie.
*Comme un transformateur deséparation des circuits pour unisolement électrique sûr entre l’entréeet la sortie.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
**As a separating transformer foradjustment of the voltage and simpleelectrical isolation.
*As an isolating transformer for thesafe electrical isolation of the input andoutput sides.
As a safety isolating transformer forthe safe electrical isolation of the inputand output sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 98 %, Indice de protection IP 00 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 98 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA Diamètre mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA Diameter mm
RKD 15/2x12 2 x 115 2x12 15 58RKD 15/2x15 2 x 115 2x15 15 58RKD 15/2x18 2 x 115 2x18 15 58RKD 20/2x12 2 x 115 2x12 20 60RKD 20/2x15 2 x 115 2x15 20 60RKD 20/2x18 2 x 115 2x18 20 60RKD 20/2x24* 2 x 115 2x24 20 60RKD 30/2x12 2 x 115 2x12 30 68RKD 30/2x15 2 x 115 2x15 30 68RKD 30/2x18 2 x 115 2x18 30 68RKD 30/2x24** 2 x 115 2x24 30 68RKD 40/2x12 2 x 115 2x12 40 74RKD 40/2x15 2 x 115 2x15 40 74RKD 40/2x18 2 x 115 2x18 40 74
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA Diamètre mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA Diameter mm
RKD 40/2x24** 2 x 115 2x24 40 74RKD 50/2x12 2 x 115 2x12 50 77RKD 50/2x15 2 x 115 2x15 50 77RKD 50/2x18 2 x 115 2x18 50 77RKD 50/2x24** 2 x 115 2x24 50 77RKD 60/2x12 2 x 115 2x12 60 80RKD 60/2x15 2 x 115 2x15 60 80RKD 60/2x18 2 x 115 2x18 60 80RKD 60/2x24** 2 x 115 2x24 60 80RKD 80/2x12 2 x 115 2x12 80 88RKD 80/2x15 2 x 115 2x15 80 88RKD 80/2x18 2 x 115 2x18 80 88RKD 80/2x24** 2 x 115 2x24 80 88RKD 100/2x12 2 x 115 2x12 100 92RKD 100/2x15 2 x 115 2x15 100 92RKD 100/2x18 2 x 115 2x18 100 92RKD 100/2x24** 2 x 115 2x24 100 92RKD 120/2x12 2 x 115 2x12 120 94RKD 120/2x15 2 x 115 2x15 120 94RKD 120/2x18 2 x 115 2x18 120 94RKD 120/2x24** 2 x 115 2x24 120 94RKD 160/2x12 2 x 115 2x12 160 105RKD 160/2x15 2 x 115 2x15 160 105RKD 160/2x18 2 x 115 2x18 160 105RKD 160/2x24** 2 x 115 2x24 160 105RKD 200/2x12 2 x 115 2x12 200 113RKD 200/2x15 2 x 115 2x15 200 113RKD 200/2x18 2 x 115 2x18 200 113RKD 200/2x24** 2 x 115 2x24 200 113RKD 225/2x12 2 x 115 2x12 225 115RKD 225/2x15 2 x 115 2x15 225 115RKD 225/2x18 2 x 115 2x18 225 115RKD 225/2x24** 2 x 115 2x24 225 115RKD 250/2x12 2 x 115 2x12 250 114RKD 250/2x18 2 x 115 2x18 250 114RKD 250/2x24** 2 x 115 2x24 250 114RKD 250/2x30** 2 x 115 2x30 250 114RKD 300/2x12 2 x 115 2x12 300 122RKD 300/2x18 2 x 115 2x18 300 122RKD 300/2x24** 2 x 115 2x24 300 122RKD 330/2x18 2 x 115 2x18 330 124RKD 400/2x18 2 x 115 2x18 400 128RKD 400/2x24** 2 x 115 2x24 400 128RKD 400/2x30** 2 x 115 2x30 400 128RKD 500/2x24 2 x 115 2x24 500 140RKD 500/2x30 2 x 115 2x30 500 140RKD 500/2x35 2 x 115 2x35 500 140RKD 625/2x30 2 x 115 2x30 625 152RKD 625/2x115 2 x 115 2x115 625 152RKD 800/2x40 2 x 115 2x40 800 170RKD 800/2x115 2 x 115 2x115 800 170RKD 1000/2x50 2 x 115 2x50 1000 168RKD 1000/2x115 2 x 115 2x115 1000 168RKD 1200/2x115 2 x 115 2x115 1200 167RKD 1600/2x115 2 x 115 2x115 1600 202RKD 2000/2x115 2 x 115 2x115 2000 203RKD 3000/2x115 2 x 115 2x115 3000 216
Transformateurs Transformers 1
39Sujet à modification
Subject to change
Transformateur torique et transformateur d’isolementToroidal safety isolating and isolating transformerRTE
W / J 2 "
AVANTAGES BENEFITS
Encombrement réduit pour despuissances élevées
Poids réduit
Tension de sortie double pour laconnexion en série ou en parallèle
Protection contre la surcharge via unprotecteur thermique intégré
Pertes à vide minimales
Comportement thermique excellentgrâce à un champ de dispersionmagnétique réduit
Très faible niveau de bruit
Minimum size at high output
Low weight
Dual output voltage for series orparallel connection
Protected against overload by integraltemperature fuse
Minimal no-load losses
Outstanding temperature behavior dueto low magnetic leakage field
Very low noise field
APPLICATIONS APPLICATIONS
**Comme un transformateurd’alimentation pour un isolementélectrique sûr entre l’entrée et lasortie.
*Comme un transformateur deséparation des circuits pour unisolement électrique sûr entre l’entréeet la sortie.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
**As a separating transformer foradjustment of the voltage and simpleelectrical isolation.
*As an isolating transformer for thesafe electrical isolation of the input andoutput sides.
As a safety isolating transformer forthe safe electrical isolation of the inputand output sides.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 95 %, Indice de protection IP 00 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 95 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA Diamètre mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA Diameter mm
RTE 15/2x12 230 2x12 15 58RTE 15/2x15 230 2x15 15 58RTE 15/2x18 230 2x18 15 58RTE 20/2x12 230 2x12 20 60RTE 20/2x15 230 2x15 20 60RTE 20/2x18 230 2x18 20 60RTE 20/2x24* 230 2x24 20 60RTE 30/2x12 230 2x12 30 68RTE 30/2x15 230 2x15 30 68RTE 30/2x18 230 2x18 30 68RTE 30/2x24* 230 2x24 30 68RTE 40/2x12 230 2x12 40 74RTE 40/2x15 230 2x15 40 74RTE 40/2x18 230 2x18 40 74
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA Diamètre mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA Diameter mm
RTE 40/2x24** 230 2x24 40 74RTE 50/2x12 230 2x12 50 77RTE 50/2x15 230 2x15 50 77RTE 50/2x18 230 2x18 50 77RTE 50/2x24** 230 2x24 50 77RTE 60/2x12 230 2x12 60 80RTE 60/2x15 230 2x15 60 80RTE 60/2x18 230 2x18 60 80RTE 60/2x24** 230 2x24 60 80RTE 80/2x12 230 2x12 80 88RTE 80/2x15 230 2x15 80 88RTE 80/2x18 230 2x18 80 88RTE 80/2x24** 230 2x24 80 88RTE 100/2x12 230 2x12 100 92RTE 100/2x15 230 2x15 100 92RTE 100/2x18 230 2x18 100 92RTE 100/2x24** 230 2x24 100 92RTE 120/2x12 230 2x12 120 94RTE 120/2x15 230 2x15 120 94RTE 120/2x18 230 2x18 120 94RTE 120/2x24** 230 2x24 120 94RTE 160/2x12 230 2x12 160 105RTE 160/2x15 230 2x15 160 105RTE 160/2x18 230 2x18 160 105RTE 160/2x24** 230 2x24 160 105RTE 200/2x12 230 2x12 200 113RTE 200/2x15 230 2x15 200 113RTE 200/2x18 230 2x18 200 113RTE 200/2x24** 230 2x24 200 113RTE 225/2x12 230 2x12 225 115RTE 225/2x15 230 2x15 225 115RTE 225/2x18 230 2x18 225 115RTE 225/2x24** 230 2x24 225 115RTE 250/2x12 230 2x12 250 114RTE 250/2x18 230 2x18 250 114RTE 250/2x24** 230 2x24 250 114RTE 250/2x30** 230 2x30 250 114RTE 300/2x18 230 2x18 300 122RTE 300/2x24** 230 2x24 300 122RTE 330/2x18 230 2x18 330 124RTE 400/2x18 230 2x18 400 128RTE 400/2x24** 230 2x24 400 128RTE 400/2x30** 230 2x30 400 128RTE 500/2x24 230 2x24 500 140RTE 500/2x30 230 2x30 500 140RTE 500/2x35 230 2x35 500 140RTE 625/2x30 230 2x30 625 152
Transformateurs Transformers1
40Sujet à modificationSubject to change
Limiteur de courant d’appel, contrôle par courant etdétection du fonctionnement à videInrush current limiter, current-controlled with no-loaddetectionESG 6
W
AVANTAGES BENEFITS
Temps de limitation dynamiques pourun démarrage optimal des chargesavec des courants d’appel élevés
Contrôle par courant avec détectiondu fonctionnement à vide, protectionde limitation du courant maximum,même en cas de remise en marchemomentanée
Boîtier en plastique robuste pourmontage sur rail DIN
Dynamic limit times for optimumstarting of loads with high inrushcurrents
Current-controlled with no-loaddetection, full current limit protection,even if momentarily switched back on
Robust plastic housing for DIN railmounting
APPLICATIONS APPLICATIONS
Temps de limitation dynamique pour undémarrage optimal des charges avecdes courants de démarrage élevés
Inrush current limiting option forlimiting the inrush current in powertools, transformers and other loadswith high switch-on or inrush currents.
DONNÉES TECHNIQUES TECHNICAL DATA
Résistance interne de 7,8 Ohm, Température ambiante de 40 °C max., Indice deprotection IP 20 Internal resistance 7.8 Ohms, Maximum ambient temperature104 °F / 40 °C, Degree of protection IP 20
Désignation duproduitN° de référence
Tension nominale Vac Courant nominal A DimensionsL/H/P en mm
Product NameOrder No.
Rated Voltage Vac Rated Current A DimensionsW/H/D in mm
ESG 6 110 - 230 ±10 % 16, (UL: 12) 72/90/59,2
Limiteurs de courantInrush current limiterES 00 / ES 30
AVANTAGES BENEFITS
Très bonne protection contre l’humiditégrâce à l'encapsulation intégrals avecnotre résine XtraDenseFill (ES30)
ES 00: Boîtier en plastique solide pourmontage à vis
ES 30: Boîtier en plastique solide pourmontage sur rail DIN pour installationdans coffrets de distribution outableaux pour compteurs électriques
Very good moisture protection dueto XtraDenseFill resin encapsulation(ES30)
ES 00: Robust plastic housing forscrewed mounting
ES 30: Robust plastic housing for DINrail mounting, e.g. in consumer units ormeter mounting boards
APPLICATIONS APPLICATIONS
Limite le courant d’appel destransformateurs à courants d’appelélevés ou les courants de démarrageélevés (ne convient pas aux machinesélectriques ou aux moteurs)
Inrush current limiting optionfor limiting the inrush current intransformers with high switch-onor inrush currents (not suited forelectrical machinery or motors).
DONNÉES TECHNIQUES TECHNICAL DATA
Résistance interne de 3,75 Ohm, Température ambiante de 40 °C max., Indicede protection IP 00 / IP 30 Internal resistance 3.75 Ohms, Maximum ambienttemperature 104 °F / 40 °C, Degree of protection IP 00 / IP 30
Désignation duproduitN° de référence
Tension nominale Vac Courant nominal A DimensionsL/H/P en mm
Product NameOrder No.
Rated Voltage Vac Rated Current A DimensionsW/H/D in mm
ES 00 220 - 400 max. 16 60/60/94ES 30 220 - 400 max. 16 71/90,4/58
Transformateurs Transformers 1
41Sujet à modification
Subject to change
Limiteur de courant d’appel, contrôle par courant etdétection du fonctionnement à videInrush current limiter, current-controlled with no-loaddetectionESG 3 / ESG 7
W
AVANTAGES BENEFITS
Temps de limitation dynamiquespour un démarrage optimal desconsommateurs avec des courantsd’appel élevés
Contrôle par courant avec détectiondu fonctionnement à vide, protectionde limitation du courant intégrale,même en cas de remise en marchemomentanée
Très bonne protection contre l’humiditégrâce à l’encapsulation intégrals avecnotre résine XtraDenseFill
ESG 3: Câble de raccordement 2 x1,4 m avec fiche contact de protectionet coupleur contact de protection DIN49440-1 (ALL)
ESG 7: 2 x câbles de connexion réseauavec raccordement dispositif bassetempérature C13 CEI 60321-1 (ALL)pour une utilisation mobile
Dynamic limit times for optimum inrushof loads with high inrush currents
Current-controlled with no-loaddetection, hence full current limitprotection, even if momentarilyswitched back on
Very good moisture protection due toXtraDenseFill resin encapsulation
ESG 3: 2 x Mains cables with safetyplug and with safety plug and safetycoupling DIN 49440-1 (GER) for mobileuse
ESG 7: 2 x Mains cable with low-heat device connection C13 IEC60321-1 (GER) for mobile use
APPLICATIONS APPLICATIONS
Limite le courant d’appel destransformateurs à courants d’appelélevés ou les courants de démarrageélevés.
Inrush current limiting option forlimiting the inrush current in powertools, transformers and other loadswith high switch-on or inrush currents.
DONNÉES TECHNIQUES TECHNICAL DATA
Résistance interne de 7,8 Ohm, Température ambiante de 40 °C max., ProtectionIP 65 (Enveloppe); IP 44 (prise/coupleur) Internal resistance 7.8 Ohm, Maximumambient temperature 104 °F / 40 °C, Degree of protection IP 65 (Enclosure); IP44 (plug/connector)
Désignation duproduitN° de référence
Tension nominale Vac Courant nominal A DimensionsL/H/P en mm
Product NameOrder No.
Rated Voltage Vac Rated Current A DimensionsW/H/D in mm
ESG 3 230 16 66/70/121ESG 7 230 10 66/70/121
Limiteur de courant d’appel, contrôle par courant etdétection du fonctionnement à videInrush current limiter, current-controlled with no-loaddetectionESG 4 / ESG 5
W
AVANTAGES BENEFITS
Temps de limitation dynamiquespour un démarrage optimal desconsommateurs avec des courantsd’appel élevés
Contrôle par courant avec détectiondu fonctionnement à vide, protectionde limitation du courant intégrale,même en cas de remise en marchemomentanée
Très bonne protection contre l’humiditégrâce à l’encapsulation intégrals avecnotre résine XtraDenseFill
ESG 4: 2 x câble de raccordement avecfiche et couplage BS 1363 (UK) pourutilisation mobile
ESG 5: 2 x câble de raccordement avecfiche et couplage NEMA5-15 (USA)pour utilisation mobile
Dynamic limit times for optimum inrushof loads with high inrush currents
Current-controlled with no-loaddetection, hence full current limitprotection, even if momentarilyswitched back on
Very good moisture protection due toXtraDenseFill resin encapsulation
ESG 4: 2 x Connection cable with plugand coupling BS 1363 (UK) for mobileuse
ESG 5: 2 x Connection cable with plugand coupling NEMA5-15 (USA) formobile use
APPLICATIONS APPLICATIONS
Pour limiter le courant d’appel desoutils électriques, transformateursou autres ayant de forts courantsd’appels.
Inrush current limiting option forlimiting the inrush current in powertools, transformers and other loadswith high switch-on or inrush currents.
DONNÉES TECHNIQUES TECHNICAL DATA
Résistance interne de 7,8 Ohm (ESG 4), 4,4 Ohms (ESG 5), Température ambiantede 40 °C max., Protection IP 65 (Enveloppe); IP 20 (prise/coupleur) Internalresistance 7.8 Ohms (ESG 4), 4.4 Ohms (ESG 5), Maximum ambient temperature104 °F / 40 °C, Degree of protection IP 65 (Enclosure); IP 20 (plug/connector)
Désignation duproduitN° de référence
Tension nominale Vac Courant nominal A DimensionsL/H/P en mm
Product NameOrder No.
Rated Voltage Vac Rated Current A DimensionsW/H/D in mm
ESG 4 230 13 66/70/121ESG 5 115 13 66/70/121
Transformateurs Transformers1
42Sujet à modificationSubject to change
Alimentation de courant alternatif pour laboratoiresAC current supply for laboratoriesBR
J !
AVANTAGES BENEFITS
Anti-court-circuit sous condition
Affichage analogique du courant et dela tension
Accès aux disjoncteurs de protectionde sortie en face avant
Poignées de transport pour uneutilisation mobile
Non-inherently short-circuit proof
Analogue current and voltage indicator
Output circuit breakers may beoperated from the front
Carry handle, mains cable with safetyplug, shockproof socket for portableapplication
APPLICATIONS APPLICATIONS
Transformateur d’isolement avectension de sortie réglable pour uneutilisation en laboratoire.
Isolating transformer with controllableoutput voltage for use in thelaboratory.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation E, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 93 %, Résistance interne de 1,80 - 4,96 Ohm, Refroidissementautomatique, Indice de protection IP 20 Insulation class E, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 93 %, Internal resistance 1.80 -4.96 Ohms, Self-cooling, Degree of protection IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
BR 351 230 0 - 250 350 318/195/225BR 1000 230 0 - 250 1.000 400/195/250BR 2200 230 0 - 250 2.200 450/300/340
Alimentation de courant alternatif pour laboratoiresAC current supply for laboratoriesBRS
J !
AVANTAGES BENEFITS
Valeurs RMS et crête du courant et dela tension
Affichage numérique du courant et dela tension
Autres paramètres: puissance active,réactive, apparente et facteur depuissance
Câble de connexion réseau avec fichede sécurité, prise de sécurité
Emplacement pour le montage dansdes armoires de 19 pouces
RMS and peak values of current andvoltage
Graphical visualization of current andvoltage curves
Other parameters: active, reactive andapparent power and power factor
Mains connection lead with safety plug,safety socket
Plug-in rack for installation in 19 inchescabinets
APPLICATIONS APPLICATIONS
Transformateur d’isolement avectension de sortie réglable pour uneutilisation en laboratoire.
Isolating transformer with controllableoutput voltage for use in thelaboratory.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 93 %, Résistance interne de 1,80 - 4,96 Ohm, Refroidissementautomatique, Indice de protection IP 20 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 93 %, Internal resistance 1.80 -4.96 Ohms, Self-cooling, Degree of protection IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
BRS 400 230 0 - 250 400 482/143/364BRS 1000 230 0 - 250 1000 482/180/364BRS 2200 230 0 - 250 2200 482/210/364
Transformateurs Transformers 1
43Sujet à modification
Subject to change
TEX-E - Fil de cuivre isolé tripleTEX-E - Triple insulated copper wireCU-TIW
AVANTAGES BENEFITS
Pas d’isolement supplémentairenécessaire entre primaire etsecondaire, veuillez prendre en compteles normes applicables
Soudable sans dénudage préalable
No additional insulation betweenprimary and secondary is necessary,please consider the relevant standards
Solderable without prior stripping
APPLICATIONS APPLICATIONS
Les fils TEX-E sont utilisés comme filsisolés dans les composants inductifs.
Veuillez prendre en compte les normesapplicables.
TEX-E wires are used as insulatedwires in inductive components.
Please consider the relevant standards.
DONNÉES TECHNIQUES TECHNICAL DATA
TIW - Fil de cuivre isolé triple, Classe de température: E 120 °C (UL: 130 °C),Tension de fonctionnement max. 1000 Vrms, Résistance à la tension: 3 kV CA1 min TIW - Triple insulated wire, Temperature class: E 248 °F / 120 °C (UL:266 °F / 130 °C), Operating voltage max. 1000 Vrms, Voltage resistance: 3kV AC1min
Désignation du produitN° de référence
Diamètredu fil mm
Longueur m(min.)
Poids kg
Product NameOrder No.
WireDiameter mm
Length m(min.)
Weight kg
CU-TIW 100/0,20 0,20 226,1 0,10CU-TIW 100/0,25 0,25 156,5 0,10CU-TIW 100/0,30 0,30 114,5 0,10CU-TIW 100/0,40 0,40 68,4 0,10CU-TIW 100/0,50 0,50 45,3 0,10CU-TIW 100/0,60 0,60 32,2 0,10CU-TIW 100/0,75 0,75 21,1 0,10CU-TIW 100/0,90 0,90 14,9 0,10
Fil de cuivre étaméCopper wire tin-platedCU-V
AVANTAGES BENEFITS
Avec étamage galvanique
Étamage conforme à la norme DIN40500
Soudable
With galvanic tin plating
Tin plating in compliance with DIN40500
Solderable
APPLICATIONS APPLICATIONS
Fil de cuivre pour le câblage descircuits et le raccordement descomposants.
Copper wire for wiring of circuitsas well as connecting wire forcomponents.
DONNÉES TECHNIQUES TECHNICAL DATA
Revêtement en étain nom. 1 µm, Diamètre du fil 0.2 - 1.5 mm Tin coating nom.1 µm, Wire diameter 0.008 to 0.06 inch
Désignation du produitN° de référence
Diamètredu fil mm
Longueur m(min.)
Poids kg
Product NameOrder No.
WireDiameter mm
Length m(min.)
Weight kg
CU-V 100/0,20 0,20 260 0,10CU-V 100/0,40 0,40 71 0,10CU-V 100/0,50 0,50 46 0,10CU-V 100/0,80 0,80 17 0,10CU-V 100/1,00 1,00 11 0,10CU-V 100/1,50 1,50 5 0,10
Transformateurs Transformers1
44Sujet à modificationSubject to change
Fil de cuivre émailléEnameled copper wireCUL
AVANTAGES BENEFITS
Vernis isolé polyuréthane min., mod.
Degré 1
TJ 155° C min.
Soudable
Insulating varnish basis min,polyurethane, mod.
Grade 1
TJ min. 302 °F / 155 °C
Solderable
APPLICATIONS APPLICATIONS
Fil de cuivre émaillé permettantla fabrication de bobines etd’enroulements, et répondant auxbesoins généraux de laboratoire.
Veuillez prendre en compte les normesapplicables.
Enameled copper wire for theproduction of coils and windings andfor general laboratory needs.
Please consider the relevant standards.
DONNÉES TECHNIQUES TECHNICAL DATA
Résistance à la chaleur 155 °C (classe F), Étamable >350 °C Long-term thermalresistance 311 °F / 155 °C (class F), May be tinned >662 °F / 350 °C
Désignation du produitN° de référence
Diamètredu fil mm
Longueur m(min.)
Poids kg
Product NameOrder No.
WireDiameter mm
Length m(min.)
Weight kg
CUL 50/0,08 0,08 856 0,05CUL 100/0,10 0,10 1144 0,10CUL 100/0,15 0,15 509 0,10CUL 100/0,22 0,22 215 0,10CUL 100/0,28 0,28 140 0,10CUL 100/0,35 0,35 87 0,10CUL 100/0,40 0,40 69 0,10CUL 100/0,50 0,50 44 0,10CUL 100/0,63 0,63 28 0,10CUL 100/0,75 0,75 20 0,10CUL 100/0,85 0,85 15 0,10CUL 100/1,00 1,00 11 0,10CUL 100/1,12 1,12 9 0,10CUL 200/0,10 0,10 2289 0,20CUL 200/0,15 0,15 1017 0,20CUL 200/0,22 0,22 429 0,20CUL 200/0,28 0,28 280 0,20CUL 200/0,35 0,35 175 0,20CUL 200/0,40 0,40 138 0,20CUL 200/0,50 0,50 88 0,20CUL 200/0,63 0,63 56 0,20CUL 200/0,75 0,75 40 0,20CUL 200/0,85 0,85 31 0,20CUL 200/1,00 1,00 22 0,20CUL 200/1,12 1,12 18 0,20
Désignation du produitN° de référence
Diamètredu fil mm
Longueur m(min.)
Poids kg
Product NameOrder No.
WireDiameter mm
Length m(min.)
Weight kg
CUL 500/0,40 0,40 345 0,50CUL 500/0,50 0,50 221 0,50CUL 500/0,63 0,63 140 0,50CUL 500/0,75 0,75 99 0,50CUL 500/0,85 0,85 77 0,50CUL 500/1,00 1,00 56 0,50CUL 500/1,12 1,12 44 0,50CUL 500/1,32 1,32 32 0,50CUL 500/1,50 1,50 25 0,50CUL 500/1,80 1,80 17 0,50CUL 500/2,00 2,00 14 0,50
Transformateurs Transformers 1
45Sujet à modification
Subject to change
Fil de cuivre émaillé isoléStranded copper litz wireCLI
AVANTAGES BENEFITS
Vernis isolé polyuréthane, mod.
Degré 1
TJ 130 °C min.
Soudable
Insulating varnish basis polyurethane,mod.
Grade 1
TJ min. 266 °F / 130 °C
Solderable
APPLICATIONS APPLICATIONS
Fil de cuivre émaillé isolé hautesfréquences permettant la fabricationde bobines et d’enroulements dansla plage de hautes fréquences, etrépondant aux besoins généraux delaboratoire.
Veuillez prendre en compte les normesapplicables.
Stranded radio frequency copper litzwire for the production of coils andwindings in the radio frequency rangeand for general laboratory needs.
Please consider the relevant standards.
DONNÉES TECHNIQUES TECHNICAL DATA
Résistance à la chaleur 130 °C (classe B), Étamable >350 °C Long-term thermalresistance 266 °F / 130 °C (class B), May be tinned >662 °F / 350 °C
Désignation du produitN° de référence
Diamètredu fil mm
Longueur m(min.)
Poids kg
Product NameOrder No.
WireDiameter mm
Length m(min.)
Weight kg
CLI 200/15 15 x 0,1 128 0,20CLI 200/30 30 x 0,1 69 0,20CLI 200/60 60 x 0,1 32 0,20CLI 200/90 90 x 0,1 22 0,20CLI 200/120 120 x 0,1 16 0,20
Fil de litz de cuivre tresséStranded and braided copper litz wireCLI-S
AVANTAGES BENEFITS
Vernis isolé polyuréthane, mod.
Degré 1
TJ 155 °C min.
Soudable
Insulating varnish basis polyurethane,mod.
Grade 1
TJ min. 311 °F / 155 °C
Solderable
APPLICATIONS APPLICATIONS
Fil de litz de cuivre tressé isolé hautesfréquences permettant la fabricationde bobines et d’enroulements dansla plage de hautes fréquences etrépondant aux besoins générauxde laboratoire. Le fil de litz HF estconstitué de fils torsadés et tressésavec un matériau textile courantenroulé.
Veuillez prendre en compte les normesapplicables.
Stranded and braided insulated radiofrequency copper litz wire for theproduction of coils and windings in theradio frequency range and for generallaboratory needs. The HF-litz wireconsists of twisted, stranded wireswith a common textile wound. Pleaseconsider the relevant standards.
DONNÉES TECHNIQUES TECHNICAL DATA
Résistance à la chaleur 155 °C (classe F), Étamable >350 °C Long-term thermalresistance 311 °F / 155 °C (class F), May be tinned >662 °F / 350 °C
Désignation du produitN° de référence
Diamètredu fil mm
Longueur m(min.)
Poids kg
Product NameOrder No.
WireDiameter mm
Length m(min.)
Weight kg
CLI-S 100/10 10 x 0,1 98 0,11CLI-S 100/20 20 x 0,1 52 0,11CLI-S 100/25 25 x 0,1 41 0,11CLI-S 100/30 30 x 0,1 37 0,11CLI-S 100/45 45 x 0,1 22 0,11CLI-S 100/60 60 x 0,1 18 0,11CLI-S 100/75 75 x 0,1 14 0,11CLI-S 100/90 90 x 0,1 12 0,11CLI-S 100/120 120 x 0,1 9 0,11
Transformateurs Transformers1
46Sujet à modificationSubject to change
Fil résistifResistance wireRD
AVANTAGES BENEFITS
Contenu en couche d’oxyde de surfaceextrêmement adhérent, à chaquevariation de température, empêchetoute oxydation supplémentaire encharge continue
Fini de haute qualité de par sasouplesse et sa douceur
Adapté à la soudure à l’étain, épaisseou autogène
Firmly adhering surface oxide coatingwithstands any temperature changeand protects against further oxidationunder continuous load
Very easy to machine due to softnessand malleability
Suitable for soft soldering, hardsoldering or welding
APPLICATIONS APPLICATIONS
Fil de résistance pour fabrication derésistance techniques et de shunts,ainsi que pour un usage général enlaboratoire.
Resistance wire for the production oftechnical resistances, shunts and forgeneral laboratory needs.
DONNÉES TECHNIQUES TECHNICAL DATA
Résistance électrique spécifique 0,49 ((Þ x mm² )/m), Température de fil autoriséemaximale jusqu’à 600 °C Specific electrical resistance 0.49 ((Þ x mm² )/m),Maximum permissible wire temperature up to 1112 °F / 600 °C
Désignation du produitN° de référence
Diamètredu fil mm
Longueur m(min.)
Poids kg
Product NameOrder No.
WireDiameter mm
Length m(min.)
Weight kg
RD 100/0,1 0,10 1144 0,10RD 100/0,2 0,20 286 0,10RD 100/0,3 0,30 127 0,10RD 100/0,4 0,40 71 0,10RD 100/0,6 0,60 32 0,10RD 100/0,8 0,80 18 0,10RD 100/1,0 1,00 11 0,10RD 100/1,2 1,20 8 0,10RD 100/1,5 1,50 5 0,10RD 100/2,0 2,00 3 0,10RD 100/3,0 3,00 1 0,10RD 100/4,0 4,00 0.7 0,10
Gaine en tissuFabric sleevingSET-G
AVANTAGES BENEFITS
Aucune perte des propriétésélectriques ou physiques (jusqu’à155 °C)
Résiste à la plupart des acides,solvants organiques, huiles et à l’eau
Bonne résistance aux alcalis
Without loss of any electrical orphysical properties (up to 311 °F /155 °C)
Resistant to most acids, organicsolvents, oils and water
Fair resistance to alkalies
APPLICATIONS APPLICATIONS
La gaine en tissu sert à isoler lescâbles et les liaisons dans les moteursà puissance fractionnaire et intégrale.Elle est particulièrement adaptée auxéquipements sensibles à l’humidité.
The fabric sleeving is used to insulateleads and crossovers in fractional andintegral horsepower motors. They areparticularly used on moisture-sensitiveequipment.
DONNÉES TECHNIQUES TECHNICAL DATA
Désignation du produitN° de référenceProduct NameOrder No.SET-G-0,5-2,8SET-G-2,9-5,7
Transformateurs Transformers 1
Unité d’emballage
Package Unit
24 pcs., Ø 0.2 - 2.8 mm16 pcs., Ø 2.9 - 5.7 mm
Longueur (mm)
Length (mm)
250250
47Sujet à modification
Subject to change
Gaine en siliconeSilicone sleevingSET-SIL
AVANTAGES BENEFITS
Protection mécanique supplémentaireaux températures élevées
Isolation électrique supplémentaire desfils de bobinage et des fils de litz
Additional mechanical protection athigh temperatures
Additional electrical insulation ofmagnet wires and litz wires
APPLICATIONS APPLICATIONS
La gaine en silicone sert de protectionmécanique supplémentaire et légèrepour les applications soumises àune très forte contrainte thermique.Elle offre par ailleurs une isolationélectrique supplémentaire pour lescâbles et les fils de cuivre émaillésutilisés dans les machines électriqueset les transformateurs ainsi que danscertaines applications électroniques.
The silicone sleeving is used aslightweight, additional mechanicalprotection for applications with veryhigh thermal stress. Furthermore, itoffers additional electrical insulation forcables and enamelled copper wires inelectric machines and transformersas well as in certain electronicapplications.
DONNÉES TECHNIQUES TECHNICAL DATA
Désignation du produitN° de référenceProduct NameOrder No.SET-SIL-0,5-3,5
Gaine thermorétractableHeat shrinkable sleevingSET-S
AVANTAGES BENEFITS
Ignifuge, difficilement inflammable
Gaine souple et hautes performances
Pour une utilisation professionnelle
Flame retardant, hardly inflammable
Flexible and high-performance sleeving
For professional use
APPLICATIONS APPLICATIONS
Gaine souple thermorétractable hautesperformances en polyoléfine. La gaineSET-S est spécialement modifiéepour répondre aux spécificationsinternationales pour une utilisationprofessionnelle.
Flexible high-performance polyolefinheat-shrinkable sleeving. SET-S isspecially modified to meet internationalspecifications for professional use.
DONNÉES TECHNIQUES TECHNICAL DATA
Désignation du produitN° de référenceProduct NameOrder No.SET-S-1,6-9,5SET-S-12,7-76
Transformateurs Transformers1
Unité d’emballage
Package Unit
12 pcs., Ø 1.6 - 9.5 mm5 pcs., Ø 12.7 - 76 mm
Longueur (mm)
Length (mm)
250250Unité d’emballage
Package Unit
28 pcs., Ø 0.5 - 3.5 mm
Longueur (mm)
Length (mm)
250
48Sujet à modificationSubject to change
Boîtier en plastiquePlastic housingTOGA
AVANTAGES BENEFITS
Entrée et sortie d'un côté
Borniers isolés pour une séparationdes circuits d'alimentation et decommande
Réglage optimisé de l'applicationnécessaire, grâce aux borniersindividuels à décharge de traction
Installation possible de la carte decircuit imprimé dans la zone d'entréeet de sortie
One-sided in- and outlet
Isolated terminal areas for aseparation of feeder and controlcircuits
Optimized adjustment to the neededapplication due to individual terminalareas with strain-relief
PCB installation in the input and outputarea possible
APPLICATIONS APPLICATIONS
Boîtier en plastique avec des fixationsmurales pour les transformateursjusqu'à 450 VA ou d'autresapplications. Entrée et sortie d'uncôté, plus borniers isolés pour uneséparation des circuits d'alimentationet de commande. Borniers individuels àdécharge de traction pour un réglageoptimisé de l'application.
Plastic housing with wall fasteningfor transformers up to 450 VA orother applications. One-sided in- andoutlet, plus isolated terminal areasfor a separation of feeder and controlcircuits. Individual terminal areas withstrain-relief for optimized adjustmentto the application.
DONNÉES TECHNIQUES TECHNICAL DATA
Montage au sol, Pour les transformateurs jusqu'à 450 VA de puissance, IP 20,IP 23 pour le montage avec la zone de serrage dirigée vers le bas Wall fastening,For transformers with power up to 450 VA, IP 20, IP 23 when mounted withclamping area directed downwards
Désignation du produitN° de référenceProduct NameOrder No.TOGA-100TOGA-450
BGE
AVANTAGES BENEFITS
Montage souple pour une installationen toute facilité
Surfaces revêtues de poudre RAL5008
Ouvertures de ventilation pour uneévacuation optimale de la chaleur
Flexible mounting for easy installation
Excellent corrosion protection and highabrasion resistance through powder-coated surface RAL 5008
Ventilation openings for optimizedcooling
APPLICATIONS APPLICATIONS
Coffret en tôle d’acier pour indice deprotection IP 23
Universal metal enclosure rated IP23.
DONNÉES TECHNIQUES TECHNICAL DATA
Indice de protection IP 23, Pour montage au sol Degree of protection IP 23, Forfloor mounting
Désignation duproduitN° de référence
Pour puissancemonophasée VA
Pour puissance(triphasée) VA
Pour indicede protection
DimensionsL/H/P en mm
Product NameOrder No.
For Power(single phase) VA
For Power(three phase) VA
For ProtectionIndex
DimensionsW/H/D in mm
BGE-050 3000 5000 IP 23 480/444/380BGE-065 6300 10.000 IP 23 630/579/405BGE-070 15.000 20.000 IP 23 680/635/500BGE-080 25.000 30.000 IP 23 780/703/620BGE-085 40.000 63.000 IP 23 860/814/710BGE-095 55.000 85.000 IP 23 950/964/810BGE-115 85.000 125.000 IP 23 1150/1070/920BGE-130 210.000 315.000 IP 23 1310/1225/1040BGE-150 420.000 630.000 IP 23 1490/1325/1040
Transformateurs Transformers 1
Ne peut pas être utilisé comme enveloppe vide! Cannot be used as empty enclosure!
EntréesInlets
11
SortiesOutlets
26
Volume de remplissage (net)Filling volume (net.)
0.46 l1.44 l
Coffret en tôleMetal enclosureBGE
49Sujet à modification
Subject to change
Coffret en tôle d’acierSheet-metal enclosureBGUK
AVANTAGES BENEFITS
Système de rail intégré pourl’installation de différentes tailles deproduits (BGUK 30 - BGUK 60)
Surfaces revêtues de poudre RAL5008
Avec des ailettes de refroidissementpour une évacuation optimale de lachaleur
Façade sans ailettes derefroidissement pour des options deconnexion individuelles (BGUK 10 - 60)
Anneaux de levage intégrés
Integrated rail system for theinstallation of different product sizes(BGUK 30 - BGUK 60)
Excellent corrosion protection and highabrasion resistance through powder-coated surface RAL 5008
Ventilation openings for optimizedcooling
Faceplate without cooling fins forindividual connection options (BGUK10 - 60)
Integrated lifting brackets
APPLICATIONS APPLICATIONS
Coffret universel en acier avecouvertures de ventilation pour indice deprotection IP20/IP23.
Universal metal enclosure withventilation openings for degree ofprotection IP20/IP23.
DONNÉES TECHNIQUES TECHNICAL DATA
Pour des puissances de 63 à 25000 VA, Indice de protection IP 20 - IP 23 , Pourun montage au sol (BGUK 1 - BGUK 3), Pour un montage mural (BGUK 10 - BGUK60) For Power 63 to 25000 VA, Degree of protection IP 20 - IP 23, For wallmounting (BGUK 1 - BGUK 3), For wall and floor mounting (BGUK 10 - BGUK 60)
Désignation duproduitN° de référence
Pour puissancemonophasée VA
Pour puissance(triphasée) VA
Pour indicede protection
DimensionsL/H/P en mm
Product NameOrder No.
For Power(single phase) VA
For Power(three phase) VA
For ProtectionIndex
DimensionsW/H/D in mm
BGUK 1 63 100 IP 20 140/150/130BGUK 2 250 160 IP 20 190/200/170BGUK 3 500 400 IP 20 230/250/210BGUK 10 1600 750 IP 23 320/250/195BGUK 20 2500 1500 IP 23 420/322/230BGUK 30 5000 3000 IP 23 470/423/265BGUK 40 10000 6300 IP 23 580/472/325BGUK 50 15000 15000 IP 23 700/572/420BGUK 60 25000 25000 IP 23 950/744/570
Coffret en tôle d’acierSheet-metal enclosureBG
AVANTAGES BENEFITS
Rail DIN Intégré pour l’installation dedifférentes tailles de produits
Surfaces revêtues de poudre RAL5008/9006
Anneaux de levage intégrés
Avec des ailettes de refroidissementpour une évacuation optimale de lachaleur
Peut être fourni avec un indice deprotection IP 54
Integrated rail system for theinstallation of different product sizes
Excellent corrosion protection and highabrasion resistance through powder-coated surface RAL 5008/9006
Integrated lifting brackets
With cooling fins for optimal heatextraction
Optionally available in degree ofprotection IP 54
APPLICATIONS APPLICATIONS
Coffret en tôle d’acier pour indice deprotection IP 23.
Universal metal enclosure rated IP23.
DONNÉES TECHNIQUES TECHNICAL DATA
Indice de protection IP 23, Pour montage au sol Degree of protection IP 23, Forfloor mounting
Désignation duproduitN° de référence
Pour puissancemonophasée VA
Pour puissance(triphasée) VA
Pour indicede protection
DimensionsL/H/P en mm
Product NameOrder No.
For Power(single phase) VA
For Power(three phase) VA
For ProtectionIndex
DimensionsW/H/D in mm
BG 240 17.000 25.000 IP 23 798/699/620BG 270 36.000 60.000 IP 23 858/809/690BG 300 53.000 80.000 IP 23 940/898/792BG 450 100.000 150.000 IP 23 1260/1141/991
Transformateurs Transformers1
50Sujet à modificationSubject to change
Transformateurs Transformers 1
51Sujet à modification
Subject to change
Transformateurs Transformers1
Aperçu des transformateurs pour circuit imprimé Overview PCB transformers
D’autres plages de tension sur demande. Different voltage ratings on request.
Type Tens
ion
nom
inal
e d’
entr
éeRa
ted
inpu
t vol
tage
Tens
ion
de s
ortie
nom
inal
eRa
ted
outp
ut v
olta
ge
Puis
sanc
ePo
wer
Prot
égé
cont
re le
s co
urts
-circ
uits
Shor
t-cir
cuit
proo
f
Tem
péra
ture
am
biant
e jus
qu’à
70°
C Am
bien
t tem
pera
ture
ta 7
0 °C
Cl.B
Tens
ion d
’entr
ée d
ouble
Du
al in
put v
olta
ge
Bride
s su
r le
boîti
er
With
fixin
g po
ints
Com
posé
d’en
roba
ge a
vec
trou
s de
mon
tage
Po
ttin
g co
mpo
und
with
mou
ntin
g ho
les
Corp
s de
bob
ine e
ncap
sulé
Enca
psul
ated
bob
bin
VB 230 Vac 6 – 48Vac 6 – 48 Vac 0,35 – 3,2Vac 0,35 – 3,2Vac 0,35 – 3,2 VA r rr r
AVB 2 x 115 Vac 6 – 48Vac 6 – 48 Vac 0,35 – 3,2Vac 0,35 – 3,2Vac 0,35 – 3,2 VA r r rr r rr r r
VC 230 Vac 6 – 48Vac 6 – 48 Vac 3,2 – 16Vac 3,2 – 16Vac 3,2 – 16 VA
VCM 230 Vac 6 – 48Vac 6 – 48 Vac 5 – 50Vac 5 – 50Vac 5 – 50 VA r
VR 230 Vac 8 – 36Vac 8 – 36 Vac 4,5 – 30Vac 4,5 – 30Vac 4,5 – 30 VA r
PT 230 Vac 6 – 48Vac 6 – 48 Vac 4,5 – 30Vac 4,5 – 30Vac 4,5 – 30 VA r r
EP 230 Vac 2 x 6 – 2 x 15Vac 2 x 6 – 2 x 15 Vac 4,5 – 35Vac 4,5 – 35Vac 4,5 – 35 VA r
FL 2 x 115 Vac 2 x 5 – 2 x 24Vac 2 x 5 – 2 x 24 Vac 2 – 52Vac 2 – 52Vac 2 – 52 VA r
FLE 230 Vac 2 x 6 – 2 x 18Vac 2 x 6 – 2 x 18 Vac 4 – 35Vac 4 – 35Vac 4 – 35 VA r
FLD 2 x 115 Vac 2 x 6 – 2 x 18Vac 2 x 6 – 2 x 18 Vac 4 – 48Vac 4 – 48Vac 4 – 48 VA r r
Outre notre service de livraison sous 24 h, découvrez notre gamme de produits standard. Pour plus d’informations, n’hésitez pas à consulter notre site block.eu.
In addition to our 24 hours BLOCK direct sales program an overview of the entire standard range. For more information see block.eu.
52Sujet à modificationSubject to change
Transformateur pour circuit imprimé protégé contreles courts-circuitsShort-circuit proof PCB transformerVB
W w J 1 &
AVANTAGES BENEFITS
Anti-court-circuit sans condition
Également fourni avec une tension desortie double pour la commutation ensérie ou en parallèle
Convient aux températures ambiantesélevées
Protection durable contre lacorrosion, valeur d’isolation élevéeet fiabilité électrique la plus élevée àl’encapsulation intégrals avec notrerésine XtraDenseFill
Autoextinguible
Inherently short-circuit proof
Dual output voltage for series orparallel connection
Designed for high ambienttemperatures
Permanent corrosion protection, highinsulation value and maximum electricalreliability due to XtraDenseFill resinencapsulation
Self-extinguishing potting material
APPLICATIONS APPLICATIONS
*Comme transformateur réseauconforme permettant l’adaptation dela tension et une isolation électriquesimple.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
*As a separating transformer foradjustment of the voltage and simpleelectrical isolation.
As a safety isolating transformer forthe safe electrical isolation of the inputand output.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 70 °C max. (VB 3,2 max. 50 °Cmax.), Degré d’efficacité jusqu’à 58 %, Indice de protection IP 00 Insulation classB, Maximum ambient temperature 158 °F / 70 °C (VB 3,2 max. 122 °F / 50 °C),Efficiency up to 58 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
VB 0,35/1/6 230 6 0,35 22,7/15/22VB 0,35/1/9 230 9 0,35 22,7/15/22VB 0,35/1/12 230 12 0,35 22,7/15/22VB 0,35/1/15 230 15 0,35 22,7/15/22VB 0,35/1/18 230 18 0,35 22,7/15/22VB 0,35/1/24 230 24 0,35 22,7/15/22VB 0,35/2/6 230 2x6 0,35 22,7/15/22VB 0,35/2/9 230 2x9 0,35 22,7/15/22VB 0,35/2/12 230 2x12 0,35 22,7/15/22VB 0,35/2/15* 230 2x15 0,35 22,7/15/22VB 0,35/2/18* 230 2x18 0,35 22,7/15/22VB 0,35/2/24* 230 2x24 0,35 22,7/15/22VB 0,5/1/6 230 6 0,5 22,7/19/22VB 0,5/1/9 230 9 0,5 22,7/19/22VB 0,5/1/12 230 12 0,5 22,7/19/22
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
VB 0,5/1/15 230 15 0,5 22,7/19/22VB 0,5/1/18 230 18 0,5 22,7/19/22VB 0,5/1/24 230 24 0,5 22,7/19/22VB 0,5/2/6 230 2x6 0,5 22,7/19/22VB 0,5/2/9 230 2x9 0,5 22,7/19/22VB 0,5/2/12 230 2x12 0,5 22,7/19/22VB 0,5/2/15* 230 2x15 0,5 22,7/19/22VB 0,5/2/24* 230 2x24 0,5 22,7/19/22VB 1,0/1/6 230 6 1 27,3/21,8/32,3VB 1,0/1/9 230 9 1 27,3/21,8/32,3VB 1,0/1/12 230 12 1 27,3/21,8/32,3VB 1,0/1/15 230 15 1 27,3/21,8/32,3VB 1,0/1/18 230 18 1 27,3/21,8/32,3VB 1,0/1/24 230 24 1 27,3/21,8/32,3VB 1,0/2/6 230 2x6 1 27,3/21,8/32,3VB 1,0/2/9 230 2x9 1 27,3/21,8/32,3VB 1,0/2/12 230 2x12 1 27,3/21,8/32,3VB 1,0/2/15 230 2x15 1 27,3/21,8/32,3VB 1,0/2/18* 230 2x18 1 27,3/21,8/32,3VB 1,0/2/24* 230 2x24 1 27,3/21,8/32,3VB 1,2/1/9 230 9 1,2 27,3/23,8/32,3VB 1,2/1/12 230 12 1,2 27,3/23,8/28,8VB 1,2/1/15 230 15 1,2 27,3/23,8/32,3VB 1,2/1/18 230 18 1,2 27,3/23,8/32,3VB 1,2/1/24 230 24 1,2 27,3/23,8/32,3VB 1,5/1/6 230 6 1,5 27,3/23,8/32,3VB 1,5/1/9 230 9 1,5 27,3/23,8/32,3VB 1,5/1/12 230 12 1,5 27,3/23,8/32,3VB 1,5/1/15 230 15 1,5 27,3/23,8/32,3VB 1,5/1/18 230 18 1,5 27,3/23,8/32,3VB 1,5/1/24 230 24 1,5 27,3/23,8/32,3VB 1,5/2/6 230 2x6 1,5 27,3/23,8/32,3VB 1,5/2/9 230 2x9 1,5 27,3/23,8/32,2VB 1,5/2/12 230 2x12 1,5 27,3/23,8/32,3VB 1,5/2/15* 230 2x15 1,5 27,3/23,8/32,2VB 1,5/2/18* 230 2x18 1,5 27,3/23,8/32,2VB 2,0/1/6 230 6 2 27,3/26,8/32,3VB 2,0/1/9 230 9 2 27,3/26,8/32,3VB 2,0/1/12 230 12 2 27,3/26,8/32,3VB 2,0/1/15 230 15 2 27,3/26,8/32,3VB 2,0/1/18 230 18 2 27,3/26,8/31,8VB 2,0/1/24 230 24 2 27,3/26,8/32,3VB 2,0/2/8 230 2x8 2 27,3/26,8/32,2VB 2,0/2/12 230 2x12 2 27,3/26,8/32,2VB 2,3/1/6 230 6 2,3 27,3/29/32,3VB 2,3/1/9 230 9 2,3 27,3/29/32,3VB 2,3/1/12 230 12 2,3 27,3/29/32,3VB 2,3/1/15 230 15 2,3 27,3/29/32,3VB 2,3/1/18 230 18 2,3 27,3/29/32,3VB 2,3/1/24 230 24 2,3 27,3/29/32,3VB 2,3/2/6 230 2x6 2,3 27,3/29/32,3VB 2,3/2/9 230 2x9 2,3 27,3/29/32,3VB 2,3/2/12 230 2x12 2,3 27,3/29/32,3VB 2,3/2/15* 230 2x15 2,3 27,3/29/32,3VB 2,8/1/6 230 6 2,8 27,3/34/32,3VB 2,8/1/9 230 9 2,8 27,3/34/32,3VB 2,8/1/12 230 12 2,8 27,3/34/32,3VB 2,8/1/15 230 15 2,8 27,3/34/32,3VB 2,8/1/18 230 18 2,8 27,3/34/32,3VB 2,8/1/24 230 24 2,8 27,3/34/32,3VB 2,8/2/9 230 2x9 2,8 27,3/34/32,3VB 2,8/2/12 230 2x12 2,8 27,3/34/32,3VB 2,8/2/18* 230 2x18 2,8 27,3/34/32,3VB 3,2/1/6 230 6 3,2 35/30,8/41VB 3,2/1/9 230 9 3,2 35/30,8/41VB 3,2/1/12 230 12 3,2 35/30,8/41VB 3,2/1/15 230 15 3,2 35/30,8/41VB 3,2/1/18 230 18 3,2 35/30,8/41VB 3,2/1/24 230 24 3,2 35/30,8/41VB 3,2/2/6 230 2x6 3,2 35/30,8/41VB 3,2/2/9 230 2x9 3,2 35/30,8/41VB 3,2/2/12 230 2x12 3,2 35/30,8/41VB 3,2/2/15* 230 2x15 3,2 35/30,8/41VB 3,2/2/18* 230 2x18 3,2 35/30,8/41VB 3,2/2/24* 230 2x24 3,2 35/30,8/41
Transformateurs Transformers 1
53Sujet à modification
Subject to change
Transformateur pour circuit-imprimé protégé contreles courts-circuitsShort-circuit proof PCB transformerAVB
W J 1 &
AVANTAGES BENEFITS
Anti-court-circuit sans condition
Tension d’entrée double pour lacommutation en série ou en parallèle
Tension de sortie double pour lacommutation en série ou en parallèle
Convient aux températures ambiantesélevées
Protection durable contre lacorrosion, valeur d’isolation élevéeet fiabilité électrique la plus élevée àl’encapsulation intégrals avec notrerésine XtraDenseFill
Autoextinguible
Inherently short-circuit proof
Dual input voltage for series or parallelconnection
Dual output voltage for series orparallel connection
Designed for high ambienttemperatures
Permanent corrosion protection, highinsulation value and maximum electricalreliability due to XtraDenseFill resinencapsulation
Self-extinguishing potting and hoodmaterial
APPLICATIONS APPLICATIONS
*Comme transformateur réseauconforme permettant l’adaptation dela tension et une isolation électriquesimple.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
*As a separating transformer foradjustment of the voltage and simpleelectrical isolation.
As a safety isolating transformer forthe safe electrical isolation of the inputand output.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 70 °C max. (AVB 3,2: 50 °C max.),Degré d’efficacité jusqu’à 59 %, Indice de protection IP 00 Insulation class B,Maximum ambient temperature 158 °F / 70 °C (AVB 3,2 max. 122 °F / 50 °C),Efficiency up to 59 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
AVB 0,35/2/6 2 x 115 2x6 0,35 22,7/15/22AVB 0,35/2/9 2 x 115 2x9 0,35 22,7/15/22AVB 0,35/2/12 2 x 115 2x12 0,35 22,7/15/22AVB 0,5/2/9 2 x 115 2x9 0,5 22,7/19/22AVB 1,0/2/12 2 x 115 2x12 1 27,3/21,8/32,3AVB 1,5/2/6 2 x 115 2x6 1,5 27,3/23,8/32,3AVB 1,5/2/8 2 x 115 2x8 1,5 27,3/23,8/32,3AVB 1,5/2/9 2 x 115 2x9 1,5 27,3/23,8/32,3AVB 1,5/2/12 2 x 115 2x12 1,5 27,3/23,8/32,3AVB 1,5/2/15 2 x 115 2x15 1,5 27,3/23,8/32,3AVB 1,5/2/18* 2 x 115 2x18 1,5 27,3/23,8/32,3AVB 2,3/2/6 2 x 115 2x6 2,3 27,3/29/32,3AVB 2,3/2/9 2 x 115 2x9 2,3 27,3/29/32,3
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
AVB 2,3/2/12 2 x 115 2x12 2,3 27,3/29/32,3AVB 2,3/2/15 2 x 115 2x15 2,3 27,3/29/32,3AVB 2,3/2/24* 2 x 115 2x24 2,3 27,3/29/32,3AVB 3,2/2/6 2 x 115 2x6 3,2 35/30,8/41AVB 3,2/2/9 2 x 115 2x9 3,2 35/30,8/41AVB 3,2/2/12 2 x 115 2x12 3,2 35/30,8/41
Transformateurs Transformers1
54Sujet à modificationSubject to change
Transformateur pour circuit-impriméPCB transformerVC
W w / J 2
AVANTAGES BENEFITS
Tension de sortie double pour lacommutation en série ou en parallèle
Protection durable contre lacorrosion, valeur d’isolation élevéeet fiabilité électrique la plus élevée àl’encapsulation intégrals avec notrerésine XtraDenseFill
Matériel de scellement à extinctionautomatique
Dual output voltage for series orparallel connection
Permanent corrosion protection, highinsulation value and maximum electricalreliability due to XtraDenseFill resinencapsulation
Self-extinguishing potting material
APPLICATIONS APPLICATIONS
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
As a safety isolating transformer forthe safe electrical isolation of the inputand output.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 - 60 °C max., Degré d’efficacitéjusqu’à 76 %, Indice de protection IP 00 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C to 140 °F / 60 °C, Efficiency up to 76 %, Degree ofprotection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
VC 5,0/1/6 230 6 5 37/33/44VC 5,0/1/9 230 9 5 37/33/44VC 5,0/1/12 230 12 5 37/33/44VC 5,0/1/15 230 15 5 37/33/44VC 5,0/1/18 230 18 5 37/33/44VC 5,0/1/24 230 24 5 37/33/44VC 5,0/2/9 230 2x9 5 37/33/44VC 5,0/2/12 230 2x12 5 37/33/44VC 5,0/2/15 230 2x15 5 37/33/44VC 10/1/6 230 6 10 43/34,6/51VC 10/1/8 230 8 10 43/34,6/51VC 10/1/9 230 9 10 43/34,6/51VC 10/1/12 230 12 10 43/34,6/51VC 10/1/15 230 15 10 43/34,6/51VC 10/1/18 230 18 10 43/34,6/51VC 10/1/24 230 24 10 43/34,6/51VC 10/2/9 230 2x9 10 43/34,6/51VC 10/2/12 230 2x12 10 43/34,6/51VC 10/2/15 230 2x15 10 43/34,6/51VC 16/1/6 230 6 16 48/39/57VC 16/1/9 230 9 16 48/39/57VC 16/1/12 230 12 16 48/39/57VC 16/1/15 230 15 16 48/39/57VC 16/1/18 230 18 16 48/39/57VC 16/1/24 230 24 16 48/39/57
Transformateur pour circuit-imprimé, montablePCB transformer, mountableVCM
W w / J 2 "
AVANTAGES BENEFITS
Tension de sortie double pour lacommutation en série ou en parallèle
Protection durable contre lacorrosion, valeur d’isolation élevéeet fiabilité électrique la plus élevée àl’encapsulation intégrals avec notrerésine XtraDenseFill
Matériel de scellement à extinctionautomatique
Possibilité de montage supplémentairepar les brides sur le boîtier
Dual output voltage for series orparallel connection
Permanent corrosion protection, highinsulation value and maximum electricalreliability due to XtraDenseFill resinencapsulation
Self-extinguishing potting material
Additional mounting option with tabs onthe housing
APPLICATIONS APPLICATIONS
**Comme un transformateur deséparation des circuits pour unisolement électrique sûr entre l’entréeet la sortie.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
**As an isolating transformer for thesafe electrical isolation of the input andoutput.
As a safety isolating transformer forthe safe electrical isolation of the inputand output.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, Température ambiante de 40 - 50 °C max., Degré d’efficacitéjusqu’à 87 %, Indice de protection IP 00 Insulation class B, Maximum ambienttemperature 104 °F / 40 °C to 122 °F / 50 °C, Efficiency up to 87 %, Degree ofprotection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
VCM 5,0/1/18 230 18 5 64/32,3/37VCM 10/1/12 230 12 10 69/34,6/42,2VCM 10/2/8 230 2x8 10 69/34,6/42,2VCM 10/2/9 230 2x9 10 69/34,6/42,2VCM 10/2/12 230 2x12 10 69/34,6/42,2VCM 10/2/15 230 2x15 10 69/34,6/42,2VCM 16/1/9 230 9 16 75,2/39/47,1VCM 16/1/12 230 12 16 75,2/39/47,1VCM 16/1/24 230 24 16 75,2/39/47,1VCM 25/1/12 230 12 25 55/49,2/81,2VCM 25/1/15 230 15 25 55/49,2/81,2VCM 25/1/18 230 18 25 55/49,2/81,2VCM 25/1/24 230 24 25 55/49,2/81,2VCM 25/2/12 230 2x12 25 55/49,2/81,2VCM 36/1/6 230 6 36 60/53,3/87,2VCM 36/1/12 230 12 36 60/48,5/87,2VCM 36/1/18 230 18 36 60/48,5/87,2VCM 36/1/24 230 24 36 60/48,5/87,2
Transformateurs Transformers 1
55Sujet à modification
Subject to change
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
VCM 36/2/12 230 2x12 36 60/48,5/87,2VCM 36/2/24** 230 2x24 36 60/48,5/87,2VCM 50/1/9 230 9 50 61/58,5/94VCM 50/1/12 230 12 50 61/58,5/94VCM 50/1/15 230 15 50 61/58,5/94VCM 50/1/18 230 18 50 61/58,5/94VCM 50/1/24 230 24 50 61/58,5/94
Transformateur pour circuit-imprimé protégé contreles courts-circuitsShort-circuit proof PCB transformerPT
W w J 1
AVANTAGES BENEFITS
Protection intégrée contre lessurcharges via PTC en entrée
Tension de sortie double pour lacommutation en série ou en parallèle
Protection durable contre lacorrosion, valeur d’isolation élevéeet fiabilité électrique la plus élevée àl’encapsulation intégrals avec notrerésine XtraDenseFill
Matériel de scellement à extinctionautomatique
Montage gain de place grâce à lafixation à vis supplémentaire dans laplaque de fond
Integrated overload protection usingPTC in the input
Dual output voltage for series orparallel connection
Permanent corrosion protection, highinsulation value and maximum electricalreliability due to XtraDenseFill resinencapsulation
Self-extinguishing potting material
Space saving installation due toadditional screw mounting in the baseplate
APPLICATIONS APPLICATIONS
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
Safety isolating transformer for thesafe electrical isolation of the input andoutput.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation E, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 83 %, Indice de protection IP 00 Insulation class E, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 83 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
PT 4,5/1/6 230 6 4,5 37/33/44PT 4,5/1/8 230 8 4,5 37/33/44PT 4,5/1/9 230 9 4,5 37/33/44PT 4,5/1/12 230 12 4,5 37/33/44PT 4,5/1/15 230 15 4,5 37/33/44PT 4,5/1/24 230 24 4,5 37/33/44PT 4,5/2/6 230 2x6 4,5 37/33/44PT 4,5/2/9 230 2x9 4,5 37/33/44PT 4,5/2/12 230 2x12 4,5 37/33/44PT 7,5/1/8 230 8 7,5 43/36/51PT 7,5/1/9 230 9 7,5 43/36/51PT 7,5/1/12 230 12 7,5 43/36/51PT 7,5/1/15 230 15 7,5 43/36/51PT 7,5/1/18 230 18 7,5 43/36/51PT 7,5/1/24 230 24 7,5 43/36/51PT 7,5/2/8 230 2x8 7,5 43/36/51PT 7,5/2/9 230 2x9 7,5 43/36/51PT 7,5/2/12 230 2x12 7,5 43/36/51PT 7,5/2/15 230 2x15 7,5 43/36/51
Transformateurs Transformers1
56Sujet à modificationSubject to change
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
PT 13/1/6 230 6 13 47/40/56PT 13/1/8 230 8 13 47/40/56PT 13/1/9 230 9 13 47/40/56PT 13/1/12 230 12 13 47/40/56PT 13/1/15 230 15 13 47/40/56PT 13/1/18 230 18 13 47/40/56PT 13/1/24 230 24 13 47/40/56PT 13/2/6 230 2x6 13 47/40/56PT 13/2/9 230 2x9 13 47/40/56PT 13/2/12 230 2x12 13 47/40/56PT 13/2/15 230 2x15 13 47/40/56PT 22/1/6 230 6 22 54/46/64PT 22/1/8 230 8 22 54/46/64PT 22/1/9 230 9 22 54/46/64PT 22/1/12 230 12 22 54/46/64PT 22/1/15 230 15 22 54/46/64PT 22/1/18 230 18 22 54/46/64PT 22/1/24 230 24 22 54/46/64PT 22/2/9 230 2x9 22 54/46/64PT 22/2/18 230 2x18 22 54/46/64PT 30/1/12 230 12 30 54/55/64PT 30/1/15 230 15 30 54/55/64PT 30/1/18 230 18 30 54/55/64PT 30/1/24 230 24 30 54/55/64PT 30/2/9 230 2x9 30 54/55/64PT 30/2/12 230 2x12 30 54/55/64PT 30/2/15 230 2x15 30 54/55/64PT 30/2/18 230 2x18 30 54/55/64
Transformateur platLow profile transformerFL
W w / J 2 "
AVANTAGES BENEFITS
Hauteur de construction faible
Tension d’entrée double pour lacommutation en série ou en parallèle
Tension de sortie double pour lacommutation en série ou en parallèle
Protection durable contre lacorrosion, valeur d’isolation élevéeet fiabilité électrique la plus élevée àl’encapsulation intégrale avec notrerésine XtraDenseFill
Matériel de scellement à extinctionautomatique
Low height
Dual input voltage for series or parallelconnection
Dual output voltage for series orparallel connection
Permanent corrosion protection, highinsulation value and maximum electricalreliability due to XtraDenseFill resinencapsulation
Self-extinguishing potting material
APPLICATIONS APPLICATIONS
*Comme un transformateurd’alimentation pour un isolementélectrique sûr entre l’entrée et lasortie.
**Comme un transformateur deséparation des circuits pour unisolement électrique sûr entre l’entréeet la sortie.
Comme un transformateur de sécuritépour un isolement électrique sûr entrel’entrée et la sortie.
*As a separating transformer foradjustment of the voltage and simpleelectrical isolation.
**As an isolating transformer for thesafe electrical isolation of the input andoutput.
As a safety isolating transformer forthe safe electrical isolation of the inputand output.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation E, Température ambiante de 40 °C max., Degré d’efficacitéjusqu’à 81 %, Indice de protection IP 00 Insulation class E, Maximum ambienttemperature 104 °F / 40 °C, Efficiency up to 81 %, Degree of protection IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
FL 2/6 2 x 115 2x6 2 44/17,6/53FL 2/8 2 x 115 2x8 2 44/17,6/53FL 2/9 2 x 115 2x9 2 44/17,6/53FL 2/12 2 x 115 2x12 2 44/17,6/53FL 2/15 2 x 115 2x15 2 44/17,6/53FL 4/6 2 x 115 2x6 4 44/20/53FL 4/8 2 x 115 2x8 4 44/20/53FL 4/9 2 x 115 2x9 4 44/20/53FL 4/12 2 x 115 2x12 4 44/20/53FL 4/15 2 x 115 2x15 4 44/20/53FL 4/18 2 x 115 2x18 4 44/20/53FL 4/24* 2 x 115 2x24 4 44/20/53
Transformateurs Transformers 1
57Sujet à modification
Subject to change
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie Vac
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vac
Power VA DimensionsW/H/D in mm
FL 6/6 2 x 115 2x6 6 44/22,8/53FL 6/8 2 x 115 2x8 6 44/22,8/53FL 6/9 2 x 115 2x9 6 44/22,8/53FL 6/12 2 x 115 2x12 6 44/22,8/53FL 6/15 2 x 115 2x15 6 44/22,8/53FL 6/18 2 x 115 2x18 6 44/22,8/53FL 6/24* 2 x 115 2x24 6 44/22,8/53FL 8/6 2 x 115 2x6 8 44/29/53FL 8/8 2 x 115 2x8 8 44/29/53FL 8/9 2 x 115 2x9 8 44/29/53FL 8/12 2 x 115 2x12 8 44/29/53FL 8/15 2 x 115 2x15 8 44/29/53FL 8/18 2 x 115 2x18 8 44/29/53FL 8/24* 2 x 115 2x24 8 44/29/53FL 10/6 2 x 115 2x6 10 57/23/68FL 10/8 2 x 115 2x8 10 57/23/68FL 10/9 2 x 115 2x9 10 57/23/68FL 10/12 2 x 115 2x12 10 57/23/68FL 10/15 2 x 115 2x15 10 57/23/68FL 10/18 2 x 115 2x18 10 57/23/68FL 10/24* 2 x 115 2x24 10 57/23/68FL 14/5 2 x 115 2x5 14 57/24,4/68FL 14/6 2 x 115 2x6 14 57/24,4/68FL 14/8 2 x 115 2x8 14 57/24,4/68FL 14/9 2 x 115 2x9 14 57/24,4/68FL 14/12 2 x 115 2x12 14 57/24,4/68FL 14/15 2 x 115 2x15 14 57/24,4/68FL 14/18 2 x 115 2x18 14 57/24,4/68FL 14/24* 2 x 115 2x24 14 57/24,4/68FL 18/6 2 x 115 2x6 18 57/27,8/68FL 18/8 2 x 115 2x8 18 57/27,8/68FL 18/9 2 x 115 2x9 18 57/27,8/68FL 18/12 2 x 115 2x12 18 57/27,8/68FL 18/15 2 x 115 2x15 18 57/27,8/68FL 18/18 2 x 115 2x18 18 57/27,8/68FL 18/24* 2 x 115 2x24 18 57/27,8/68FL 24/5 2 x 115 2x5 24 57/31,4/68FL 24/6 2 x 115 2x6 24 57/31,4/68FL 24/8 2 x 115 2x8 24 57/31,4/68FL 24/9 2 x 115 2x9 24 57/31,4/68FL 24/12 2 x 115 2x12 24 57/31,4/68FL 24/15 2 x 115 2x15 24 57/31,4/68FL 24/18 2 x 115 2x18 24 57/31,4/68FL 24/24* 2 x 115 2x24 24 57/31,4/68FL 30/6 2 x 115 2x6 30 57/35,8/68FL 30/8 2 x 115 2x8 30 57/35,8/68FL 30/9 2 x 115 2x9 30 57/35,8/68FL 30/12 2 x 115 2x12 30 57/35,8/68FL 30/15 2 x 115 2x15 30 57/35,8/68FL 30/18 2 x 115 2x18 30 57/35,8/68FL 30/24** 2 x 115 2x24 30 57/35,8/68FL 42/6 2 x 115 2x6 42 70/39/83,5FL 42/8 2 x 115 2x8 42 70/39/83,5FL 42/9 2 x 115 2x9 42 70/39/83,5FL 42/12 2 x 115 2x12 42 70/39/83,5FL 42/15 2 x 115 2x15 42 70/39/83,5FL 42/18 2 x 115 2x18 42 70/39/83,5FL 42/24** 2 x 115 2x24 42 70/39/83,5FL 52/6 2 x 115 2x6 52 70/49/86,5FL 52/8 2 x 115 2x8 52 70/49/86,5FL 52/9 2 x 115 2x9 52 70/49/86,5FL 52/12 2 x 115 2x12 52 70/49/86,5FL 52/15 2 x 115 2x15 52 70/49/86,5FL 52/18 2 x 115 2x18 52 70/49/86,5FL 52/24** 2 x 115 2x24 52 70/49/86,5
Transformateurs Transformers1
58Sujet à modificationSubject to change
Transformateurs Transformers 1
59Sujet à modification
Subject to change
Transformatoren Transformers1
Envoyez-nous vosspécifications afin d’obtenir un devis.
Send us your specification for
a quote.
En matière de composants inductifs,
vous trouverez en BLOCK un partenaire
efficace. Les séries limitées ou les produc-
tions en grands nombres ne présentent
aucun problème. Pour ses composants
d’alimentation à découpage, outre le fait
qu’ils soient performants même dans les
espaces les plus restreints, qu’ils aient été
soumis à un travail de précision et qu’ils
respectent les normes internationales,
BLOCK s’est fixé les critères de qualité
suivants:
r Respect de l’environnement
r Capacité de recyclage
r Dernières normes de qualité
internationales
When it comes to inductive components
BLOCK provides excellent service to fulfil
your needs. The smallest batches or large-
scale production are no problem. Along-
side product performance in the smallest
spaces and precision workmanship, the
following quality requirements are also
increasing:
r Environmental sustainability
r Recycable
r The latest international quality standards
COMPOSANTS INDUCTIFS COMPONENTS FOR SWITCHED MODE POWER SUPPLIES
60Sujet à modificationSubject to change
Transformatoren Transformers 1
r Transformateurs d’amorçage
r Transformateurs rétroéclairés
r Transformateurs convertisseurs directs à un transistor
r Selfs antiparasites
r Transformateurs push-pull
r Transformateurs convertisseurs demi-pont
r Transformateurs HF
r Inductances série
r Transformateurs de puissance jusqu’à 1 kW
r Bobines de réactance à noyau poudre métallique
r Bobines de réactance CPR
r Commutateur mode transformateur
r Bobines de stockage
r Capteurs de courant
r Transformateurs de courant
r Transformateurs TinySwitch
r Transformateurs TOPSwitch
r Translateurs
r Transformateurs convertisseurs pont intégral
r Drive transmitters
r Backlight transmitters
r Single-ended flow converter transformers
r RFI reactors
r Push-pull transformers
r Half-bridge transformers
r High-frequency transformers
r Series inductors
r Power transmitters up to 1 kW
r Iron powder core reactors
r PFC reactors
r SMPS transformers
r Storage reactors
r Current sensors
r Current converters
r TinySwitch transformers
r TOPSwitch transformers
r Repeating coils
r Full-bridge transformers
61Sujet à modification
Subject to change
EXEMPLE:9 modulesPuissance: 250 kVATension primaire: 600 VTension secondaire: 750 VFréquence: 20 kHzPoids: 60 kgPRO-CONNECT
EXEMPLE:2 modulesPuissance: 55 kVATension primaire: 600 VTension secondaire: 750 VFréquence: 20 kHzPoids: 15 kg
TRANSFORMATEURS MFTransformateur moyenne fréquence modulaire avec puissance nominale évolutive, adap-té à une installation dans des environnements pollués (PD4), entrée de câbles conforme IP65, préparé pour un refroidissement par air forcé (3 m/s)
NOS SOLUTIONS POUR UN TRANSFERT DE PUISSANCE OPTIMAL
EXAMPLE:9 Modules Power: 250 kVAPrimary voltage: 600 VSecondary voltage: 750 VFrequency: 20 kHzWeight: 60 kg PRO-CONNECT
EXAMPLE:2 Modules Power: 55 kVAPrimary voltage: 600 VSecondary voltage: 750 VFrequency: 20 kHzWeight: 15 kg
OUR SOLUTIONS FOR OPTIMAL POWER TRANSFER
MF-TRANSFORMERModular medium frequency transformer with scalable power rating, suitable for mounting in polluted environments (PD4), cable entry according to IP65 Prepared for forced air cooling with 3 m/s
TRANSFORMATEURS MF
MF-TRANSFORMERS
Transformatoren Transformers1
62Sujet à modificationSubject to change
TRANSFORMATEURS MFTransformateur moyenne fré-quence encapsulé pour installati-on sur un dissipateur thermique ou dans la paroi d’un conteneur
EXEMPLE:Puissance: 40 kVATension primaire: 500 VTension secondaire: 600 VFréquence: 8 kHzPoids: 20 kg
TRANSFORMATEURS MFEnsemble transformateur moyenne fréquence composé de quatre transformateurs. Adapté à une installation dans des environnements pollués (PD4)
EXEMPLE:Puissance: 2 x 100 kVA / 2 x 20 kVATension primaire: 600 VTension secondaire: 750 V / 150 VFréquence: 18 kHzPoids: 65 kgPRO-CONNECT
TRANSFORMATEURS MFTransformateur moyenne fréquence à refroidissement par air adapté à une installation dans des environnements pollués (PD4) EXEMPLE:Puissance: 110 kVATension primaire: 650 VTension secondaire: 700 V / 130 V)Fréquence de commutation: 7 kHzMéthode de refroidissement: flux d’air forcé 3 m/sPoids: 45 kg
MF-TRANSFORMEREncapsulated medium frequency transformer for mounting on heat sink or into container wall
EXAMPLE:Power: 40 kVAPrimary voltage: 500 VSecondary voltage: 600 VFrequency: 8 kHzWeight: 20 kg
MF-TRANSFORMERMedium frequency transformer assembly with four single transformers. Suitable for mounting in polluted environments (PD4)
EXAMPLE:Power: 2 x 100 kVA / 2 x 20 kVAPrimary voltage: 600 VSecondary voltage: 750 V / 150 VFrequency: 18 kHzWeight: 65 kg PRO-CONNECT
MF-TRANSFORMERAir-cooled medium frequency transformer suitable for mounting in polluted environ-ments (PD4) EXAMPLE:Power: 110 kVAPrimary voltage: 650 VSecondary voltage: 700 V / 130 VSwitching frequency: 7 kHzCooling method: forced air flow 3 m/sWeight: 45 kg
Nous serons ravis de recevoir votre demande.We look forwardto receiving yourrequest.
Transformatoren Transformers 1
63Sujet à modification
Subject to change
Transformateurs Transformers
AlimentationsPower supplies2
Inductances/Filtres CEMReactors/EMI filters3
NouveautésNews0
ü Alimentations à découpage Switched mode power suppliesü Pilote de LED LED driversü Disjoncteurs électroniques Electronic circuit breakersü Modules de redondance Redundancy modulesü Alimentations secourues Uninterruptible power suppliesü Modules batterie Battery modulesü Modules tampon Buffer modulesü Alimentations CC Transformer power supplies
1
64Sujet à modificationSubject to change
2
65
AlimentationsPower supplies2
Aperçu des alimentations à découpage Overview switched mode power supplies
Tension nominale de
sortieRated output
voltage
Plage de tension de
sortieOutput
voltage range
TypeType
Plage de tension d’entrée
Input voltage range 0
– 20
W
20 –
30W
40 –
60W
70 –
100
W
120
W
180
– 24
0W
450
– 48
0W
750
– 96
0W
Mon
opha
sé
Sing
le-p
hase
5 V 4.5 – 8.5Vdc Power Eco LineVdc Power Eco LineVdc Power Eco Line 85 – 264Vac 5.5A
12V
11 – 18Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vac 6A 10A 10A 15A 15A
11.5 – 15Vdc Power CompactVdc Power CompactVdc Power Compact 85 – 264Vac 15A
11.5 – 14.5Vdc Power MiniVdc Power MiniVdc Power Mini 85 – 264Vac 2A 4A 4A 7A 7A
10.5 – 15.5Vdc Power Eco LineVdc Power Eco LineVdc Power Eco Line 85 – 264Vac 2A 4A 4A 6.5A 6.5A
18V 15.5 – 19V 15.5 – 19Vdc Power Eco LineVdc Power Eco LineVdc Power Eco Line 85 – 264Vac 1.1Vac 1.1Vac 1.1A 2.5A 2.5A 2.5A 2.5A
24V
22 – 29.5Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vac 3A 5A 5A 10A 10A 20A 20A
23 – 28.5Vdc Power CompactVdc Power CompactVdc Power Compact 85 – 264Vac 5A 10A 10A 20A 20A
23 – 28.5Vdc Power MiniVdc Power MiniVdc Power Mini 85 – 264Vac 1A 2A 2A 3.8/4A
22.8 – 26.4Vdc Power Eco Line / Neo 85 – 264Vdc Power Eco Line / Neo 85 – 264Vdc Power Eco Line / Neo 85 – 264Vdc Power Eco Line / Neo 85 – 264Vdc Power Eco Line / Neo 85 – 264Vdc Power Eco Line / Neo 85 – 264Vdc Power Eco Line / Neo 85 – 264Vac 1.3A 2.5A 2.5A 4A 4A
30V 27 – 43V 27 – 43Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vac 15A
30.5V 29 – 32V 29 – 32Vdc Power Vision AS-i 85 – 264Vdc Power Vision AS-i 85 – 264Vdc Power Vision AS-i 85 – 264Vdc Power Vision AS-i 85 – 264Vdc Power Vision AS-i 85 – 264Vdc Power Vision AS-i 85 – 264Vdc Power Vision AS-i 85 – 264Vac 3A
48 V
33 – 52Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vdc Power Vision Economy 85 – 264Vac 5A 10A 10A
40 – 56Vdc Power CompactVdc Power CompactVdc Power Compact 85 – 264Vac 5A 10A 10A
40 – 56Vdc Power MiniVdc Power MiniVdc Power Mini 85 – 264Vac 2A
2p 2
p
24 V23 – 28.5Vdc Power Compact 180 – 550Vdc Power Compact 180 – 550Vdc Power Compact 180 – 550Vdc Power Compact 180 – 550Vdc Power Compact 180 – 550Vdc Power Compact 180 – 550Vdc Power Compact 180 – 550Vac 5A 10A 10A
23 – 28.5Vdc Power MiniVdc Power MiniVdc Power Mini 180 – 575Vac 3.8A
Trip
hasé
Th
ree-
phas
e
24V
22.8 – 28.8Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vac 10A 20A 20A 40A 40A
23 – 28.5Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vac 10A 20A 20A 40A 40A
22.8 – 28.8Vdc Power Vision Basic 340 – 550Vdc Power Vision Basic 340 – 550Vdc Power Vision Basic 340 – 550Vdc Power Vision Basic 340 – 550Vdc Power Vision Basic 340 – 550Vdc Power Vision Basic 340 – 550Vdc Power Vision Basic 340 – 550Vac 10A 20A 20A 40A 40A
22.8 – 28.8Vdc Power Vision Line 340 – 550Vdc Power Vision Line 340 – 550Vdc Power Vision Line 340 – 550Vdc Power Vision Line 340 – 550Vdc Power Vision Line 340 – 550Vdc Power Vision Line 340 – 550Vdc Power Vision Line 340 – 550Vac 10A 20A 20A 40A 40A
30V 27 – 43V 27 – 43Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vac 25A
48V37 – 51Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vdc Power Vision Economy 340 – 550Vac 10A 20A 20A
40 – 56Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vac 20A
60V 40 – 61V 40 – 61Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vdc Power Compact 320 – 575Vac 16A
Outre notre service de livraison sous 24 h, découvrez notre gamme de produits standard. Pour plus d’informations, n’hésitez pas à consulter notre site block.eu.
In addition to our 24 hours BLOCK direct sales program an overview of the entire standard range. For more information see block.eu.
66Sujet à modificationSubject to change
Alimentation à découpage primaire monophaséeSingle-phase, primary switched mode power supplyPEL 230
W o J #
AVANTAGES BENEFITS
Tension de sortie stabilisée et réglable
Signalisation CC OK par LED
Système de connecteur à ressort faciled’entretien
Stabilized and adjustable output voltage
DC OK indicator
Service-friendly spring-loadedconnector system
APPLICATIONS APPLICATIONS
Alimentation à découpage offrant uneexcellente solution technologique. Profilde position plat optimisé pour lescoffrets de distribution de l’immotique.
Best-in-class power quality for controlpanels in any application. Low profiledimensions allow usage mostlyeverywhere.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +55 °C, Degré d’efficacité jusqu’à 88%, Indicede protection IP 20 Ambient temperature -13 °F / -25 °C to +131 °F / +55 °C,Efficiency up to 88 %, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PEL 230/5-5,5 100 - 240 5 5,50 72/89/59PEL 230/12-2 100 - 240 12 2,00 54/89/59PEL 230/12-4 100 - 240 12 4,00 72/89/59PEL 230/12-6,5 100 - 240 12 6,50 90/89/59PEL 230/18-1,1 100 - 240 18 1,10 54/89/59PEL 230/18-2,5 100 - 240 18 2,50 72/89/59
Alimentation à découpage primaire monophaséeSingle-phase, primary switched mode power supplyPEL Neo
W o J #
AVANTAGES BENEFITS
Tension de sortie stabilisée et réglable
Signalisation CC OK par LED
Bornes de raccordement type push-in
Stabilized and adjustable output voltage
DC OK indicator
Push-in terminals
APPLICATIONS APPLICATIONS
Alimentation à découpage offrant uneexcellente solution technologique. Profilde position plat optimisé pour lescoffrets de distribution de l’immotique.
Best-in-class power quality for controlpanels in any application. Low profiledimensions allow usage mostlyeverywhere.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +55 °C, Degré d’efficacité jusqu’à 88%, Indicede protection IP 20 Ambient temperature -13 °F / -25 °C to +131 °F / +55 °C,Efficiency up to 88 %, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PEL-0124-013-0 100 - 240 24 1,30 54/89/59PEL-0124-025-0 100 - 240 24 2,50 72/89/59PEL-0124-040-0 100 - 240 24 4,00 90/89/59
AlimentationsPower supplies 2
67Sujet à modification
Subject to change
Alimentation à découpage primaire monophaséeSingle-phase, primary switched mode power supplyPM 1AC
W o J y #
AVANTAGES BENEFITS
Tension de sortie stabilisée et réglable
Faibles pertes à vide <1 W
Limitation de courant constante sansdéclenchement en cas de surcharge
Signalisation CC OK
Montage sur DIN rail
Stabilized and adjustable output voltage
Low stand-by consumption <1 W
Constant current limiting withoutoverload shutdown
DC OK indicator
Panel installation on mounting rails
APPLICATIONS APPLICATIONS
Alimentation à découpage à hautrendement, avec une enveloppeplastique de faible encombrement.Ces dispositifs couvrent les petiteset moyennes puissances de 25 W à100 W.
Efficient primary switched mode powersupplies in a rugged plastic housing.The power supplies cover the lowerpower requirements in the range from25 W to 100 W.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Indice de protection IP 20 Ambienttemperature: -13 °F / -25 °C to 158 °F / +70 °C, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PM-0112-020-0 100 - 240 12 2 22,5/90/98PM-0112-040-0 100 - 240 12 4 45/90/98PM-0112-070-0 100 - 240 12 7 22,5/90/111PM-0124-010-0 100 - 240 24 1 22,5/90/98PM-0124-020-0 100 - 240 24 2 45/90/98PM-0124-038-0 100 - 240 24 3,8 / NEC Class 2 52/90/111PM-0124-040-0 100 - 240 24 4 52/90/111PM-0130-030-0 100 - 240 30,5 3 52/90/111PM-0148-020-0 100 - 240 48 2 52/90/111
Alimentation à découpage primaire bi-phaséeTwo-phase, primary switched mode power supplyPM 2AC
W o J
AVANTAGES BENEFITS
Tension de sortie stabilisée et réglable
Faibles pertes à vide <1 W
Limitation de courant constante sansdéclenchement en cas de surcharge
Signalisation CC OK
Bornes de raccordement type push-in
Stabilized and adjustable output voltage
Low stand-by consumption <1 W
Constant current limiting withoutoverload shutdown
DC OK indicator
Push-in terminals
APPLICATIONS APPLICATIONS
Alimentation à découpage à hautrendement, avec une enveloppeplastique de faible encombrement. Ledispositif satisfait les exigences de lanorme NEC Classe 2.
Efficient primary switched mode powersupplies in a rugged plastic housing.The device meets the requirements ofNEC Class 2.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Enveloppe plastique Ambienttemperature -13 °F / -25 °C to +158 °F / +70 °C, Plastic housing
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PM-0224-038-0 200 - 500 24 3,8 / NEC Class 2 52/90/111
AlimentationsPower supplies2
NEC Classe 2 en option. NEC Class 2 optional.
NEC Classe 2 NEC Class 2
68Sujet à modificationSubject to change
Alimentation à découpage primaire monophaséeSingle-phase, primary switched mode power supplyPC 1AC
W o J #
AVANTAGES BENEFITS
Tension de sortie stabilisée et réglable
Déclenchement rapide des disjoncteurs
Signalisation CC OK
Connexion en parallèle possible
Bornes de raccordement type Push-in
Montage sur rail DIN robuste
Stabilized and adjustable output voltage
Fast tripping of conventional circuitbreakers
DC OK indicator
Parallel operation
Push-in terminals
Robust DIN rail mounting
APPLICATIONS APPLICATIONS
Power Compact combine lesfonctions de base d’une alimentationà découpage économique avec desfonctionnalités supplémentaires quipermettent une disponibilité maximalede l’installation.
Power Compact combines the basicfunctionality of an economic powersupply with the essential featuresto maximize the availability of yoursystem.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Degré d’efficacité jusqu’à 93 %, Indicede protection IP 20 Ambient temperature -13 °F / -25 °C to +158 °F / +70 °C,Efficiency up to 93 %, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PC-0112-150-0 100 - 240 12 15 55/127/161PC-0124-050-0 100 - 240 24 5 42/127/126PC-0124-050-4 100 - 240 24 5 42/127/136PC-0124-100-0 100 - 240 24 10 55/127/161PC-0124-100-4 100 - 240 24 10 42/127/136PC-0124-200-0 100 - 240 24 20 95/127/159PC-0148-050-0 100 - 240 48 5 55/127/161PC-0148-100-0 100 - 240 48 10 95/127/159
Alimentation à découpage primaire monophasée,version EconomySingle-phase, primary switched mode power supply,EconomyPVSE 230
W o J
AVANTAGES BENEFITS
Tension de sortie stabilisée et réglable
Jusqu’à 200 % de vrai Power Boostpendant 4 secondes
Réserve de puissance pour ledéclenchement fiable de disjoncteurs(Top Boost)
Signalisation CC OK
Entrée Stand-by
Système de connecteur à ressort faciled’entretien
Stabilized and adjustable output voltage
Up to 200 % Real Power Boost for4 seconds
Top Boost to trip conventional circuitbreakers
DC OK indicator
Stand-by-input
Service-friendly spring-loadedconnector system
APPLICATIONS APPLICATIONS
Alimentation à découpage primaireavec d’importantes réserves depuissance.
Primary switched mode power supplywith massive power reserves focussingon the key task of power supply.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Degré d’efficacité jusqu’à 92 %, Ambient temperature -13 °F / -25 °C to +158 °F / +70 °C, Efficiency up to 92 %,
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PVSE 230/12-6 100 - 240 12 6,00 40/127/170,5PVSE 230/12-10 100 - 240 12 10,00 57/127/170,5PVSE 230/12-15 100 - 240 12 15,00 57/127/179,5PVSE 230/24-3 100 - 240 24 3,00 40/127/163,5PVSE 230/24-5 100 - 240 24 5,00 57/127/163,5PVSE 230/24-10 110 - 240 24 10,00 57/127/179,5PVSE 230/24-20 110 - 240 24 20,00 97/127/187,5PVSE 230/30-15 110 - 240 30 15,00 97/127/187,5PVSE 230/48-5 110 - 240 48 5,00 57/127/179,5PVSE 230/48-10 110 - 240 48 10,00 97/127/187,5
AlimentationsPower supplies 2
En option avec limiteur de courant d’appel actif. Optional with active inrush current limiter.
69Sujet à modification
Subject to change
Alimentation à découpage primaire monophasée etbiphaséeSingle- and two-phase, primary switched mode powersupplyPC 2AC
W o J #
AVANTAGES BENEFITS
Tension de sortie stabilisée et réglable
Déclenchement rapide des disjoncteurs
Signalisation CC OK
Connexion en parallèle possible
Bornes de raccordement type push-in
Montage sur rail DIN robuste
Stabilized and adjustable output voltage
Fast tripping of conventional circuitbreakers
DC OK indicator
Parallel operation
Push-in terminals
Robust DIN rail mounting
APPLICATIONS APPLICATIONS
Power Compact combine lesfonctionnalités de base d’unealimentation économique et lesfonctions nécessaires pour optimiser ladisponibilité de votre système.
Power Compact combines the basicfunctionality of an economic powersupply with the essential featuresto maximize the availability of yoursystem.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Indice de protection IP 20 Ambienttemperature -13 °F / -25 °C to +158 °F / +70 °C, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PC-0224-050-0 200 - 500 24 5 42/127/126PC-0224-050-2 200 - 500 24 5 42/127/126PC-0224-100-0 200 - 500 24 10 55/127/137PC-0224-100-2 200 - 500 24 10 55/127/137
Alimentation à découpage primaire triphaséeThree-phase primary switched mode power supplyPC 3AC
W o J #
AVANTAGES BENEFITS
Tension de sortie stabilisée et réglable
Déclenchement rapide des disjoncteurs
Signalisation CC OK
Connexion en parallèle possible
Bornes de raccordement type push-in
Montage sur rail DIN robuste
En option, avec 50% de réserve depuissance (PC-03xx-xxx-2)
Stabilized and adjustable output voltage
Fast tripping of conventional circuitbreakers
DC OK indicator
Parallel operation
Push-in terminals
Robust DIN rail mounting
Optional with 50 % Power Boost(PC-03xx-xxx-2)
APPLICATIONS APPLICATIONS
Power Compact combine lesfonctionnalités de base d’unealimentation économique et lesfonctions nécessaires pour optimiser ladisponibilité de votre système.
Power Compact combines the basicfunctionality of an economic powersupply with the essential featuresto maximize the availability of yoursystem.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Indice de protection IP 20 Ambienttemperature -13 °F / -25 °C to +158 °F / +70 °C, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PC-0324-100-0 400 - 500 24 10 55/127/161PC-0324-200-2 400 - 500 24 20 80/127/160PC-0324-400-0 400 - 500 24 40 126/127/178PC-0324-400-2 400 - 500 24 40 126/127/178PC-0348-200-0 400 - 500 48 20 126/127/178PC-0348-200-2 400 - 500 48 20 126/127/178
AlimentationsPower supplies2
70Sujet à modificationSubject to change
Alimentation à découpage primaire triphasée, versionEconomyThree-phase, primary switched mode power supply,EconomyPVSE 400
W o J
AVANTAGES BENEFITS
Tension de sortie stabilisée et réglable
Jusqu’à 200 % de vrai Power Boostpendant 4 secondes
Réserve de puissance pour ledéclenchement fiable de disjoncteurs(Top Boost)
Signalisation CC OK
Système de connecteur à ressort faciled’entretien
Stabilized and adjustable output voltage
Up to 200 % Real Power Boost for4 seconds
Top Boost to trip conventional circuitbreakers
DC OK indicator
Service-friendly spring-loadedconnector system
APPLICATIONS APPLICATIONS
Alimentation à découpage primaireavec d’importantes réserves depuissance axée sur les tâchesprincipales de l’alimentation en tensionet en courant.
Primary switched mode power supplywith massive power reserves focussingon the key task of power supply.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Degré d’efficacité jusqu’à 95 %, Indicede protection IP 20 Ambient temperature -13 °F / -25 °C to +158 °F / 70 °C,Efficiency up to 95 %, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PVSE 400/24-10 3 x 400 - 500 24 10,00 57/127/179,5PVSE 400/24-20 3 x 400 - 500 24 20,00 77/127/179,5PVSE 400/24-40 3 x 400 - 500 24 40,00 128/127/205,5PVSE 400/30-25 3 x 400 - 500 30 25,00 128/127/205,5PVSE 400/48-10 3 x 400 - 500 48 10,00 77/127/179,5PVSE 400/48-20 3 x 400 - 500 48 20,00 128/127/205,5
Alimentation à découpage primaire triphasée, versionBasicThree-phase, primary switched mode power supply,BasicPVSB 400
W o J
AVANTAGES BENEFITS
Affichage LCD
Surveillance du courant et de la tensionde sortie
Interface RS-232
Tension de sortie stabilisée et réglable
Jusqu’à 200 % de vrai Power Boostpendant 4 secondes
Réserve de puissance pour ledéclenchement fiable de disjoncteurs(Top Boost)
Signalisation de l’état defonctionnement par 3 LED et dessorties de signal actives
Système de connecteur à ressort faciled’entretien
LCD
Output current and output voltagemonitoring
RS-232 interface
Stabilized and adjustable output voltage
Up to 200 % real power boost for4 seconds
Top Boost to trip conventional circuitbreakers
3 LEDs and active signal outputs toindicate operating status
Service-friendly spring-loadedconnector system
APPLICATIONS APPLICATIONS
Alimentation à découpage primaireavec d’importantes réserves depuissance pour répondre à toutes lesexigences du domaine de l’automationavec une multitude de fonctions deparamétrage et d’affichage, tellesque la surveillance de la tension et ducourant de sortie.
Primary switched mode power supplywith high power reserves for allautomation requirements with a varietyof parameter setting and displayfunctions, including output current andoutput voltage monitoring.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Degré d’efficacité jusqu’à 94 %, Indicede protection IP 20 Ambient temperature - 13 °F / -25 °C to +158 °F / +70 °C,Efficiency up to 94 %, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PVSB 400/24-10 3 x 400 - 500 24 10,00 57/127/179,5PVSB 400/24-20 3 x 400 - 500 24 20,00 77/127/179,5PVSB 400/24-40 3 x 400 - 500 24 40,00 128/127/205,5
AlimentationsPower supplies 2
En option avec limiteur de courant d’appel actif. Optional with active inrush current limiter.
71Sujet à modification
Subject to change
Alimentation à découpage primaire triphasée, versionLineThree-phase, primary switched mode power supply,LinePVSL 400
W o J
AVANTAGES BENEFITS
Surveillance de l’entrée du réseau
Affichage LCD
Surveillance du courant et de la tension
Interface RS-232
Tension de sortie stabilisée et réglable
Jusqu’à 200 % de vrai Power Boostpendant 4 secondes
Réserve de puissance pour ledéclenchement fiable de disjoncteurs(Top Boost)
Signalisation de l’état defonctionnement par 3 LED et dessorties de signal actives
Power input monitoring
LCD
Output current and output voltagemonitoring
RS-232 interface
Stabilized and adjustable output voltage
Up to 200 % real power boost for4 seconds
Top Boost to trip conventional circuitbreakers
3 LEDs and active signal outputs toindicate operating status
APPLICATIONS APPLICATIONS
Alimentation à découpage primaireavec d’importantes réserves depuissance pour répondre à toutes lesexigences du domaine de l’automationavec une multitude de fonctions deparamétrage et d’affichage, tellesque la surveillance de la tension et ducourant de sortie.
Primary switched mode power supplywith high power reserves for allautomation requirements with a varietyof parameter setting and displayfunctions, including output current andoutput voltage monitoring.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Degré d’efficacité jusqu’à 94 %, Indicede protection IP 20 Ambient temperature -13 °F / -25 °C to +158 °F / +70 °C,Efficiency up to 94 %, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PVSL 400/24-10 3 x 400 - 500 24 10,00 57/127/179,5PVSL 400/24-20 3 x 400 - 500 24 20,00 77/127/179,5PVSL 400/24-40 3 x 400 - 500 24 40,00 128/127/205,5
Pilote LED à courant constant pour LED hautepuissanceConstant current LED driver for High Power LEDPLED
v J
AVANTAGES BENEFITS
Variantes gradables disponibles (10 -100 %)
Grande robustesse contre lessurtensions transitoires
Protection des LED contre les picsde tension et les surchauffes (NTCexternes disponibles)
Plage de tension de sortie très étenduepour un large choix d’utilisations
Longue durée de vie
Dimmable versions available (10 -100 %)
Extremely robust against transientovervoltages
Protection of LEDs against voltagepeaks and overtemperature (externalNC required)
Very wide output voltage range for awide range of applications
Long service life
APPLICATIONS APPLICATIONS
Signalisation par LED avec exigencesaccrues en matière de résistance auxsurtensions
Outdoor LED lightning with increasedovervoltage resistance requirements
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +60 °C, Degré d’efficacité jusqu’à 90 %, Indicede protection IP 20 Ambient temperature -13 °F / -25 °C to +140 °F / +60 °C,Efficiency up to 90 %, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PLED-0194-007-0 220 - 240 max. 94 350 mA / 700 mA 40/148,5/32PLED-0194-007-1 220 - 240 max. 94 350 mA / 700 mA 40/148,5/32PLED-0194-011-0 220 - 240 max. 94 700 mA / 1050 mA 65/148,5/32PLED-0194-011-1 220 - 240 max. 94 700 mA / 1050 mA 65/148,5/32
AlimentationsPower supplies2
72Sujet à modificationSubject to change
AlimentationsPower supplies 2
73Sujet à modification
Subject to change
AlimentationsPower supplies2
Aperçu des disjoncteurs électroniques Overview electronic circuit breakers
Type Econ
omy S
mar
t
Econ
omy R
emot
e
Basic
Sm
art
Basic
Fix
Easy
B
r rr r r Caractéristique thermomagnétique Thermomagnetic characteristic
r Limitation active du courant à 1,7 x INActive current limiting typ. 1.7 x Irated
* Limitation active du courant à 1,3 x INActive current limiting typ. 1.3 x Irated
r Limitation active du courant à 1,25 x INActive current limiting typ. 1.25 x Irated
* ** * Limitation active du courant selon NEC Class 2 (100 W) Active current limiting according to NEC Class 2 (100 W)
r r rr r rr r rr r rr r rr r r Courants de déclenchement régables via un commutateurAdjustable tripping current via current selector switch
r Courants de déclenchement régables pour chaque voie via une interface à 2 filsAdjustable tripping current via 2-wire-interface
r r r r rr r r r rr r r r rr r r r rr r r r r LED d’étatStatus LED
r r r rr r r rr r r rr r r r Activation/désactivation à distance de la voie désiréeRemote switching ”On“/”Off“ for each channel
r r r r rr r r r rr r r r rr r r r rr r r r r Transmission de l’état “On”/”Off”/“Déclenché” pour chaque voieStatustransmission ”On“/”Off“/”Tripped“ per channel
r r rr r rr r r Transmission de l’état “Surintensité” pour chaque voieStatustransmission ”Overcurrent“ per channel
r r r rr r r rr r r rr r r r Transmission de l’état “tension d’entrée actuelle”/“seuil de déclenchement” pour chaque voieTransmission of ”actual input voltage“/”adjusted tripping current“ per channel
r Transmission de la donnée “courant de sortie actuel” pour chaque voieTransmission of ”actual tripping current“ per channel
r r r r rr r r r rr r r r rr r r r rr r r r r Message collectif pour toutes les sorties déclenchéesGroup alarm message for tripped channels
r r r rr r r rr r r rr r r r Reset à distance des voies déclenchéesRemote reset of tripped channels
r r r rr r r rr r r rr r r r Technologie d’enfichage direct à ressortSpring-loaded direct plug-in technology
r r r rr r r rr r r rr r r r UL/GL certificationUL/GL approval
* Uniquement pour des disjoncteurs spécifiques Only for specific circuit breakers
Outre notre service de livraison sous 24 h, découvrez notre gamme de produits standard. Pour plus d’informations, n’hésitez pas à consulter notre site block.eu.
In addition to our 24 hours BLOCK direct sales program an overview of the entire standard range. For more information see block.eu.
74Sujet à modificationSubject to change
AlimentationsPower supplies 2
Aperçu modules supplémentairesOverview additional modules
Mod
ules
de re
dond
ance
Alim
enta
tions
sec
ouru
es
Mod
ules
tam
pon
Type PELR
PC R
E
PC-0
424-
017-
0
PC-0
424-
115-
0
PC-0
524-
500-
0
PVUA
Kom
bi UP
S
PVUC
r r rr r rr r rr r rr r r Sortie découplée 24 VDecoupled 24 V output
r r rr r rr r r r Commutation parallèle pour augmentation de la puissanceParallel switching for increased power
r r r r r rr r r r r rr r r r r rr r r r r rr r r r r rr r r r r rr r r r r rr r r r r r Surveillance de la fonction par des contacts sans potentielFunction monitoring through isolated contacts
r Surveillance de la fonction par des contacts de signal 24 VFunction monitoring through 24 V signal contacts
r Affichage pour indication du courant et de la tensionDisplay for current and voltage indicator
r rr r Interface RS-232RS-232 interface
r r rr r rr r r Interface USB USB interface
r r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r r LED d’état multicoloreMulti-colored status LED
r r r rr r r rr r r rr r r rr r r rr r r rr r r rr r r rr r r rr r r r Technologie d’enfichage direct type push-inPush-in direct plug-in technology
r r r rr r rr r rr r rr r rr r rr r rr r rr r r Technologie d’enfichage à ressortSpring-loaded plug-in connection technology
r r rr r rr r r UL certificationUL approval
r GL certificationGL approval
75Sujet à modification
Subject to change
Disjoncteur à 1 voie1-Channel circuit breakerEasyB
W U J
AVANTAGES BENEFITS
Connexion transversale automatique detous les niveaux de signaux
Connexion de bus en option via desmodules de couplage
Disjoncteur à minimum de tensionassocié en option
Possibilité de réglage du courant dedéclenchement en option
Sorties de charge supplémentairesvia des modules juxtaposables dedistribution du potentiel
Activation sélective dépendante de lacharge
Variantes avec entrée de réinitialisationcollective
Automatic channel assignment
Optional communication viacommunication modules
Optional undervoltage shutdown incombined network
Optional settings for tripping current
Additional load outputs through outputexpanders mountable sidewise
Selective load-dependent activation
Versions with common reset input
APPLICATIONS APPLICATIONS
EasyB offre une grande flexibilité pourla protection des circuits au niveau dela tension de commande 24V. Grâceau concept à une voie, cette protections’adapte aux exigences de l’installationet peut être enrichie avec elle.
EasyB offers a flexible solution forprotecting switching circuits at the24 V control voltage level. Due to thesingle-channel concept, this protectioncan be adapted to the requirements ofthe system and enhanced with it.
DONNÉES TECHNIQUES TECHNICAL DATA
Degré d’efficacité 99 %, Température ambiante de -25 °C à +70 °C, Indice deprotection IP 20 Efficiency 99 %, Ambient temperature -13 °F / -25 °C to+158 °F / 70 °C, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
EB-0824-100-0 24 24 0,5 - 10, réglable(0,5A, 1A, 2A, 3A, 4A,5A, 6A, 8A, 10A)
12/99/64
EB-1824-010-0 24 24 1 12/99/64EB-1824-020-0 24 24 2 12/99/64EB-1824-030-0 24 24 3 12/99/64EB-1824-040-0 24 24 4 12/99/64EB-1824-060-0 24 24 6 12/99/64EB-1824-080-0 24 24 8 12/99/64EB-1824-100-0 24 24 10 12/99/64EB-2724-010-0 24 24 1 12/99/64EB-2724-010-4 24 24 1 12/99/64EB-2724-020-0 24 24 2 12/99/64EB-2724-020-4 24 24 2 12/99/64EB-2724-030-0 24 24 3 12/99/64EB-2724-030-4 24 24 3 12/99/64EB-2724-040-0 24 24 4 12/99/64
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
EB-2724-040-4 24 24 4 12/99/64EB-2724-060-0 24 24 6 12/99/64EB-2724-060-4 24 24 6 12/99/64EB-2724-080-0 24 24 8 12/99/64EB-2724-080-4 24 24 8 12/99/64EB-2724-100-0 24 24 10 12/99/64EB-2724-100-4 24 24 10 12/99/64EB-2824-010-0 24 24 1 12/99/64EB-2824-010-4 24 24 1 12/99/64EB-2824-020-0 24 24 2 12/99/64EB-2824-020-4 24 24 2 12/99/64EB-2824-030-0 24 24 3 12/99/64EB-2824-030-4 24 24 3 12/99/64EB-2824-040-0 24 24 4 12/99/64EB-2824-040-4 24 24 4 12/99/64EB-2824-060-0 24 24 6 12/99/64EB-2824-060-4 24 24 6 12/99/64EB-2824-080-0 24 24 8 12/99/64EB-2824-080-4 24 24 8 12/99/64EB-2824-100-0 24 24 10 12/99/64EB-2824-100-4 24 24 10 12/99/64EB-3824-100-0 24 24 0,5 - 10, réglable
(0,5A, 1A, 2A, 3A, 4A,5A, 6A, 8A, 10A)
12/99/64
AlimentationsPower supplies2
76Sujet à modificationSubject to change
Disjoncteur à 2 voies2-Channel circuit breakerEasyB
J
AVANTAGES BENEFITS
Design compact – 2 canauxindépendants pour une épaisseur deseulement 12 mm
Connexion transversale automatique detous les niveaux de signaux
Sorties de charge supplémentairesvia des modules juxtaposables dedistribution du potentiel
Compact design - 2 independentchannels in 12 mm width
Automatic channel assignment
Additional load outputs through outputexpanders mountable sidewise
APPLICATIONS APPLICATIONS
EasyB offre une grande flexibilité pourla protection des circuits au niveau dela tension de commande 24 V. Grâceau concept à une voie, cette protections’adapte aux exigences de l’installationet peut être enrichie avec elle.
EasyB offers a flexible solution forprotecting switching circuits at the24 V control voltage level. Due to themodular system, this protection canbe adapted to the requirements of thesystem and enhanced with it.
DONNÉES TECHNIQUES TECHNICAL DATA
Degré d’efficacité 99 %, Température ambiante de -25 °C à +55 °C / +70 °C,Indice de protection IP 20 Efficiency 99 %, Ambient temperature -13 °F / -25 °Cto +131 °F/ +55 °C / +158 °F / +70 °C, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
EB-2724-2020-0 24 24 2 x 1 12/99/64EB-2724-2040-0 24 24 2 x 2 12/99/64EB-2724-2060-0 24 24 2 x 3 12/99/64EB-2724-2080-0 24 24 2 x 4 12/99/64EB-2724-2120-0 24 24 2 x 6 12/99/64EB-2724-2160-0 24 24 2 x 8 12/99/64
Borne collective de terreGround moduleEB-GND
W U J
AVANTAGES BENEFITS
Borne collective 0 V avec 4 ou8 entrées
EB-GND4: Sortie pour le retour jusqu’à40 A sur l’alimentation fournie
Courant jusqu’à 40 A par module
0 V paralled terminal with 4 or8 inputs
EB-GND4: Output to feed back up to40 A to the power supply provided
Total current up to 40 A per module
APPLICATIONS APPLICATIONS
Borne collective de terre pour leretour du signal 0 V au niveau del’alimentation en remplacement du blocde jonction.
Ground module to feed back the0 V signal to the power supply as areplacement for the series terminal.
DONNÉES TECHNIQUES TECHNICAL DATA
Tension nominale d’entrée 12/24/48 V CC, Courant nominal de sortie max. 40 A,Température ambiante de -40 °C à +70 °C Input rated voltage 12/24/48 Vdc,Output rated current max. 40 A, Ambient temperature -40 °F / -40 °C to+158 °F / +70 °C
Désignation du produitN° de référenceProduct NameOrder No.EB-GND4EB-GND8
AlimentationsPower supplies 2
77Sujet à modification
Subject to change
Module de communication pour la gamme de produitsEasyBCommunication modules for the EasyB seriesEB-COMMUNICATION
U J
AVANTAGES BENEFITS
Interface intelligente pour la lecture etl’écriture des informations des modulesEasyB connectés
Canaux commutables individuellement
Courant de déclenchement réglable
Intelligent interface for reading andwriting of information of connectedEasyB modules
EasyB channels switchable individually
Can be used to adjust tripping current
APPLICATIONS APPLICATIONS
Modules de couplage comme interfacede connexion à un dispositif decommande principal. Compatibilité avecles variantes de disjoncteurs EB-08,EB-18 et EB-38.
Communication modules as interfacefor connecting a higher-level controller.Compatible with circuit breakers inEB-08, EB-18, and EB-38 versions.
DONNÉES TECHNIQUES TECHNICAL DATA
Tension nominale d’entrée 24 Vdc, Indice de protection IP 20, Températureambiante de -25 °C à +70 °C Input rated voltage 24 Vdc, Protection index IP 20,Ambient temperature -13 °F / -25 °C to +158 °F / +70 °C
Désignation du produitN° de référenceProduct NameOrder No.EB-MODBUS-RTUEB-IO-LINKEB-IO-LINK1
Accessoires pour la gamme de produits EasyBAccessories for the EasyB seriesEB-PMM / EB-PT2-0 / EB-COV / EB-BAR / EB-MARK
J
AVANTAGES BENEFITS
EB-PMM: Distribution du potentiel pourjuxtaposition côté droit au niveau ducanal du disjoncteur EasyB
EB-PT2-0: Séparateur de potentielbipolaire
EB-COV: Couverture des modulesEasyB sur le côté gauche pourprotéger les disjoncteurs contre toutcontact involontaire
EB-BAR: Connecteur transversal pourrépartition de la tension de 24 V CCsur tous les modules EasyB en contact
EB-MARK1: Étiquette de 5 mm pourmodules EasyB
EB-MARK20: Porte-étiquette pourl’insertion de bandes d’étiquetage de11 mm EB-MARK21
EB-MARK21: Bandes d’étiquetage11 mm à insérer dans le porte-étiquette EB-MARK20
EB-PMM: Output expander formounting on right side of EasyB circuitbreaker channel
EB-PT2-0: 2-pole physical isolation
EB-COV: Left side cover of theEasyB module as protection fromunintentional contact with the circuitbreaker
EB-BAR: Power bus bar for distributionof 24 Vdc voltage to all contactedEasyB modules
EB-MARK1: 5 mm label plate forinsertion into EasyB modules
EB-MARK20: Label brackets forinsertion of 11 mm EB-MARK21 labelstrips
EB-MARK21: 11 mm label stripsfor insertion into EB-MARK20 labelbrackets
APPLICATIONS APPLICATIONS
Accessoires pour la gamme deproduits EasyB
Accessories for the EasyB series
DONNÉES TECHNIQUES TECHNICAL DATA
Désignation du produitN° de référenceProduct NameOrder No.EB-PMMEB-PT2-0EB-COVEB-BAREB-MARK1EB-MARK20EB-MARK21
AlimentationsPower supplies2
Unité d’emballagePackaging unit
4 pcs.
1500 pcs.50 pcs.50 m
78Sujet à modificationSubject to change
Disjoncteur électronique à courbe de déclenchementmagnéto thermiqueElectronic circuit breaker with thermomagneticcharacteristicECONOMY SMART
o U J N
AVANTAGES BENEFITS
Courant nominal ajustable pour chaquevoie via un commutateur situé enfaçade du disjoncteur
Déclenchement fiable pour des chargesavec de fortes capacités
Commutation des voies séquentielle etdépendante de la charge
Diagnostics monovoie complets etactivation/désactivation à distancede chaque voie de sortie à l’aide dedeux fils uniquement ou Contact designalisation libre de potential
Signalisation par LED et requête àdistance, pour chaque voie
Erreur de somme
Adjustable tripping current for eachoutput channel via current selectorswitch
Ability to turn-on high load capacitanceat each channel
Sequential and load-dependentswitching-on of channels
Comprehensive single-channel-diagnostics and remote switching on/off of each output channel using onlytwo lines or potential-free signal output
LED signalization and remote requestfor each output channel
Group alarm contact
APPLICATIONS APPLICATIONS
Les disjoncteurs électroniquesECONOMY SMART, avec une courbede déclenchement magnétothermiquesont une alternative économique auxdisjoncteurs traditionnels. Ils assurentun déclenchement sûr, même en casde résistance de ligne importante.Ils sont la solution idéale pour lesfabricants de machine.
ECONOMY SMART circuit breakerswith a thermomagnetic characteristicrepresent an economical alternative tothe classic circuit breaker. They alsoensure reliable tripping even in thecase of high line resistance. This makesthe circuit breakers ideal for use instandard machine production.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Indice de protection IP 20, Degréd’efficacité typ. 99 % Ambient temperature -13 °F / -25 °C to +158 °F /+70 °C, Protection index IP 20, Efficiency typ. 99 %
Désignation du produitN° de référence
Tensiond'entrée V CC
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vdc
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PM-0712-200-0 12 12 2 x 2 - 10, réglable 45/90/91,5PM-0712-400-0 12 12 4 x 2 - 10, réglable 45/90/91,5PM-0724-120-0 24 24 2 x 1 - 6, réglable 45/90/91,5PM-0724-200-0 24 24 2 x 2 - 10, réglable 45/90/91,5PM-0724-240-0 24 24 4 x 1 - 6, réglable 45/90/91,5PM-0724-400-0 24 24 4 x 2 - 10, réglable 45/90/91,5PM-0724-400-0I1 24 24 4 x 1 - 10, réglable 45/90/91PM-0748-200-0 48 48 2 x 2 - 10, réglable 45/90/91,5PM-0748-400-0 48 48 4 x 2 - 10, réglable 45/90/91,5PC-0724-480-0 24 24 8 x 1 - 6, réglable 42/127/116,5PC-0724-800-0 24 24 8 x 2 - 10, réglable 42/127/116,5PC-0748-800-0 48 48 8 x 2 - 10, réglable 42/127/124PC-0724-800-0I1 24 24 8 x 1 - 10, réglable 42/127/116
Disjoncteur électronique avec limitation active ducourantElectronic circuit breaker with current limitingBASIC SMART
o U J N
AVANTAGES BENEFITS
Courant nominal ajustable pour chaquevoie via un commutateur situé enfaçade du disjoncteur
Coupure sélective immédiate descircuits défectueux en cas de tensiond’alimentation critique
Commutation des voies séquentielle etdépendante de la charge
Diagnostics monovoie complets etactivation/désactivation à distance dechaque voie de sortie à l’aide de deuxfils uniquement
Transmission à distance de la tensiond’entrée et des courants de sortie
Erreur de somme
Adjustable tripping current for eachoutput channel via current selectorswitch
Selective immediate switch off ofdefective circuits in the event of criticalsupply voltage
Sequential and load-dependentswitching-on of channels
Comprehensive single-channel-diagnostics and remote switching on/off of each output channel using onlytwo lines
Further diagnoses of input voltage andthe current of each circuit
Group alarm contact
APPLICATIONS APPLICATIONS
Les disjoncteurs électroniques BASICSMART garantissent une disponibilitémaximale des installations. En cas desurcharge, seule la voie défectueusesera déclenchée, sans affecter lesautres voies grâce à la limitationactive du courant à 1.7 fois le courantnominal.
The BASIC SMART circuit breakersguarantee maximum systemavailability. In the event of overload, onlythe faulty current paths are reliablyswitched off without affecting theremaining circuits due to active currentlimiting to 1.7 times the rated current.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Indice de protection IP 20, Degréd’efficacité typ. 99 % Ambient temperature -13 °F / -25 °C to +158 °F /+70 °C, Protection index IP 20, Efficiency typ. 99 %
Désignation du produitN° de référence
Tensiond'entrée V CC
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vdc
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PM-0824-120-0 24 24 2 x 0,5 - 6 45/90/90,5PM-0824-240-0 24 24 4 x 0,5 - 6 45/90/90,5PC-0824-480-0 24 24 8 x 0,5 - 6 42/127/116,5
AlimentationsPower supplies 2
79Sujet à modification
Subject to change
Disjoncteur électronique avec limitation active ducourant; sans réglage des seuils de courant dedéclenchementElectronic circuit breaker with current limiting and non-adjustable tripping currentsBASIC FIX
o U J # N
AVANTAGES BENEFITS
Coupure sélective immédiate descircuits défectueux en cas de tensiond’alimentation critique
Commutation des voies séquentielle etdépendante de la charge
Diagnostics monovoie complets etactivation/désactivation à distance dechaque voie de sortie à l’aide de deuxfils uniquement
Erreur de somme
Selective immediate switch off ofdefective circuits in the event of criticalsupply voltage
Sequential and load-dependentswitching-on of channels
Comprehensive single-channel-diagnostics and remote switching on/off of each output channel using onlytwo lines
Group alarm contact
APPLICATIONS APPLICATIONS
Pour des circuits conçus avec lesmêmes valeurs de protection, lesdisjoncteurs électroniques BASIC FIXsont la solution la plus économique.Différentes combinaisons de courantnominal permettent une large gammed’application. Chaque voie possède unelimitation active du courant à 1.3 fois lecourant nominal prédéfini.
If circuits are designed with thesame safety values in a numberof applications, the BASIC FIXcircuit breakers represent the mosteconomical basis. Different ratedcurrent combinations enable use ina wide range of applications. Eachchannel features active current limitingto 1.3 times the fixed preset ratedcurrent.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Indice de protection IP 20, Degréd’efficacité typ. 99 % Ambient temperature -13 °F / -25 °C to +158 °F /+70 °C, Protection index IP 20, Efficiency typ. 99 %
Désignation du produitN° de référence
Tensiond'entrée V CC
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vdc
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PM-9824-076-0 24 24 2 x 3,8 (NEC Class2)
42/127/116,5
PM-9824-152-0 24 24 4 x 3,8 @ 24 V (NECClass 2)
42/127/116,5
Module de redondanceRedundancy modulePELR
AVANTAGES BENEFITS
Signalisation par LED
Système de connecteur à ressort faciled’entretien
Signaling via LEDs
Service-friendly spring-loadedconnector system
APPLICATIONS APPLICATIONS
Module de redondance pour ledécouplage de deux alimentations decourant dans le cadre de la mise enœuvre d’un système d’alimentationà sécurité intégrée. Convient auxmachines et installations dont lesexigences en fiabilité de fonctionnementsont élevées.
Redundancy module for decoupling twopower supplies for building a fail-safesupply system. Set of machines andequipment requiring high operationalreliability.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +55 °C, Degré d’efficacité typ. 97 %, Indicede protection IP 20 Ambient temperature -13 °F / -25 °C to +131 °F / +55 °C,Efficiency typ. 97 %, Protection index IP 20
Désignation du produitN° de référence
Tensiond'entrée V CC
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vdc
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PELR 24/24-5 24 24 10 54/89/59
AlimentationsPower supplies2
NEC Classe 2 en option. NEC Class 2 optional.
80Sujet à modificationSubject to change
Module de redondance Power CompactRedundancy module Power CompactPC RE
#
AVANTAGES BENEFITS
Degré d’efficacité élevé
Message d’erreurs via un contact derelais et des LEDs
Connexion en parallèle sûre pouraugmenter la puissance
Entièrement compatible avec le Top etle Power Boost de vos alimentations àdécoupage
Perte de puissance minimale mêmedans le cas d’un court-circuit côtésecondaire
High efficiency
Power Good via relay contact and LEDs
Safe parallel operation to increasepower
Fully compatible with Top and PowerBoost for your power supplies
Active operation for minimal powerloss even in the event of a short-circuiton the secondary side
APPLICATIONS APPLICATIONS
Module de redondance pour ledécouplage de deux alimentationslors de l’installation d’un systèmeen alimentation électrique sécurisé.Convient aux machines et installationsdont les exigences en fiabilité defonctionnement sont élevées.
Redundancy module for decoupling twopower supplies when configuring a fail-safe supply system. For machines andsystems which place high demands onoperational safety.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -40 °C à +70 °C, Degré d’efficacité >99 %, Indice deprotection IP 20 Ambient temperature -40 °F / -40 °C to +158 °F / +70 °C,Efficiency >99 %, Protection index IP 20
Désignation du produitN° de référence
Tensiond'entrée V CC
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vdc
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PC-0624-400-0 24 24 40,00 42/127/112,5
Alimentation secourueUninterruptible power supplyPC Combi UPS
W o #
AVANTAGES BENEFITS
Alimentation incluant une unité decharge et de contrôle
Déclenchement rapide des disjoncteurs
Gestion optimale de la batterie
Signalisation fiable lorsque la durée devie restante des modules de batterieconnectés est faible
Durée de vie plus longue grâce à lagestion des batteries par contrôle de latempérature
Interface permettant de visualiser etd’ajuster les données appropriées
Combined power supply with chargingand controlling unit
Fast tripping of conventional circuitbreakers
Battery modules detectedautomatically
Reliable signaling when there is lowremaining life expectancy of connectedbattery modules
Extended life expectancy throughtemperature controlled batterymanagement
Interface to visualize and adjustrelevant data
APPLICATIONS APPLICATIONS
Module de charge et de commandepour la mise en œuvre d’unealimentation 24 V CC/5 A sécurisée encas de panne de secteur. Nécessite unmodule de batterie PVAF ou PVA.
The uninterruptible power supplyPower Compact contains an economicDC 24 V/5 A power supply with basicspecifications for industrial computerand also a charging and controllingunit for an ideal battery management.Requires a battery module PVAF orPVA.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +70 °C, Indice de protection IP 20 Ambienttemperature: -13 °F / -25 °C to +158 °F / +70 °C, Protection index IP 20
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PC-1024-050-0 100 - 240 24 5,00 60/127/136
AlimentationsPower supplies 2
81Sujet à modification
Subject to change
Alimentation secourueUninterruptible power supplyPVUA
W o
AVANTAGES BENEFITS
Protection électronique contre lasurcharge et les courts-circuits
Limitation de courant active en casd’erreur
Signal d’avertissement précoce fiablelorsque la durée de vie de la batteriediminue
Durée de vie plus longue grâce à lagestion des batteries par contrôle de latempérature
Système de connecteur à ressort faciled’entretien
Contact de signalisation libre depotentiel
Protection contre la décharge profondede la batterie
Interface permettant de visualiser etd’ajuster les données appropriées
Surveillance du courant et de la tension
Sorties de signal actives de lasurveillance des fonctions
Interface RS-232
Sortie découplée
Electronic overcurrent and short-circuitprotection
Active current limiting in the event ofan error
Reliable early warning signal whenbattery life expectancy is declining
Extended life expectancy throughtemperature controlled batterymanagement
Service-friendly spring-loadedconnector system
Isolated signal contact
Exhaustive discharge protection forbatteries
Interface to visualize and adjustrelevant data
Current and voltage monitoring
Active signal outputs for functionmonitoring
RS-232 interface
Reliable supply of industrial PC's
APPLICATIONS APPLICATIONS
Module de charge et de commandepour la mise en œuvre d’unealimentation 24 V CC sécurisée en casde panne de secteur.
Load and control module for building asecure 24 Vdc power supply in case ofpower failure.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -25 °C à +60 °C, Degré d’efficacité jusqu’à 97 %, Indicede protection IP 20 Ambient temperature -13 °F / -25 °C to +140 °F / +60 °C,Efficiency up to 97 %, Protection index IP 20
Désignation du produitN° de référence
Tensiond'entrée V CC
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vdc
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PVUA 24/24-10 24 24 10,00 40/127/163,5PVUA 24/24-20 24 24 20,00 57/127/163,5
Onduleur à batterieBattery-powered UPSPC-0524-400-0
AVANTAGES BENEFITS
Détection automatique des modules debatteries dans l'unité de commande del'onduleur
Signal d'avertissement précoce etfiable quand la durée de vie de labatterie décline
Durée de vie plus longue en raisondu système de gestion de batterie àtempérature contrôlée
Informations complémentairesconcernant l'état de charge etl'autonomie restante des batteries
Automatic detection of batterymodules at UPS control unit
Reliable early warning signal whenbattery life expectancy is declining
Extended life expectancy throughtemperature controlled batterymanagement
Additional information about chargestatus and remaining time of batteries
APPLICATIONS APPLICATIONS
Unité de charge et de commandepour les batteries au plomb afin degarantir une alimentation électriquesans coupure.
Charge- and control unit for leadbatteries for guaranteeing anuninterruptible power supply.
DONNÉES TECHNIQUES TECHNICAL DATA
Tension nominale d'entrée 24 V CC, Tension nominale de sortie 24 V CC,Température ambiante de -25 °C à +60 °C Input rated voltage 24 Vdc, Outputrated voltage 24 Vdc , Ambient temperature -13 °F to +104 °F
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PC-0524-400-0 24 24 40 45/127/136
AlimentationsPower supplies2
82Sujet à modificationSubject to change
Module batterieBattery modulePVAF
W
AVANTAGES BENEFITS
Détection automatique des modulesbatterie au niveau de l’unité de contrôleUPS
Signal d’avertissement précoce fiablelorsque la durée de vie de la batteriediminue
Durée de vie plus longue grâce à lagestion des batteries par contrôle de latempérature
Système de connecteur à ressort faciled’entretien
Automatic detection of batterymodules at UPS control unit
Reliable early warning signal whenbattery life expectancy is declining
Extended life expectancy throughtemperature controlled batterymanagement
Service-friendly spring-loadedconnector system
APPLICATIONS APPLICATIONS
Module batterie pour la mise en œuvred’une alimentation 24 V CC sécuriséeen cas de panne de secteur.
Battery module for building a secure24 Vdc power supply in case of powerfailure.
DONNÉES TECHNIQUES TECHNICAL DATA
Capacité 0,8 - 12 Ah, Température ambiante de -10 °C à +40 °C, Indice deprotection IP 20 Capacity 0.8 to 12 Ah, Ambient temperature 14 °F / -10 °C to+104 °F / +40 °C, Protection index IP 20
Désignation du produitN° de référence
Tensiond'entrée V CC
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vdc
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PVAF 24/0,8Ah 24 24 max. 5,00 72/97/107PVAF 24/1,2Ah 24 24 max. 7,50 55/131/136,5PVAF 24/3,2Ah 24 24 max. 20,00 78/145/168,5PVAF 24/7Ah 24 24 max. 40,00 163/145/176PVAF 24/12Ah 24 24 max. 40,00 230/145/176
Onduleur capacitifCapacitive UPSPC-0424-017-0
AVANTAGES BENEFITS
Jusqu'à 40 A de courant de sortie
Périodes tampon longues de l'ordre dela minute
Maintenance minimale en raisonde la longue durée de vie dessupercondensateurs
Paramétrage via commutateur rotatifou interface USB
Prise USB résistante aux chocs et auxvibrations
Up to 40 A output current
Long buffer times up to the minuterange
Minimal maintenance due to long life ofthe ultra-capacitors
Parameterization via rotary switch orvia USB interface
Shock and vibration-proof USB socket
APPLICATIONS APPLICATIONS
Module tampon sans entretien pour laprotection de la tension d’alimentationdans le cas de brèves interruptionsréseau.
Maintenance-free capacitive UPS tosecure the power supply during shortpower interruptions.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -40 °C à +60 °C, Degré d’efficacité typ. 99 %, Indicede protection IP 20 Ambient temperature -40 °F / -10 °C to +140 °F / +60 °C,Efficiency typ. 99 %, Protection index IP 20
Désignation du produitN° de référence
Tensiond'entrée V CC
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vdc
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PC-0424-017-0 24 24 20 55/127/139
AlimentationsPower supplies 2
83Sujet à modification
Subject to change
Module de réserve d'énergie capacitifCapacity modulePC-0424-115-0
AVANTAGES BENEFITS
Extension de la période tampon del'UPS PC-0424-017-0
Communication par câble bus système
Adressage automatique
Périodes tampon très longuesréalisables
Extension of the buffer time ofPC-0424-017-0
Communication through system buscable
Automatic addressing
Very long buffer times achievable
APPLICATIONS APPLICATIONS
En conjonction avec le module debase, possibilité d'augmenter lecourant de sortie jusqu'à 40 A. Ilest possible d'augmenter la périodetampon en ayant recours au module derenforcement des capacités.
In conjunction with the base module,the output current can be increased to40A. By using the capacity module, thebuffer time can be increased.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -40 °C à +60 °C Ambient temperature -40 °F /-25 °C to +140 °F / +60 °C
Désignation du produitN° de référenceProduct NameOrder No.PC-0424-115-0
Module tamponBuffer modulePVUC
o
AVANTAGES BENEFITS
Protection électronique contre lasurcharge et les courts-circuits
Protection contre les inversions depolarité
Seuil de connexion réglable
Signalisation par LED 3 x
Contact de signalisation à contact sec
Système de connecteur à ressort faciled’entretien
Sortie découplée
Electronic overcurrent and short-circuitprotection
Reverse polarity protection
Configurable switch-in threshold
3 LEDs for signaling purposes
Isolated signal contact
Service-friendly spring-loadedconnector system
Decoupled output
APPLICATIONS APPLICATIONS
Module tampon sans entretien pour laprotection de la tension d’alimentationdans le cas de brèves interruptionsréseau.
Service-free buffer module to securethe power supply during short powerinterruptions.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante de -10 °C à +60 °C, Degré d’efficacité typ. 97 %, Indicede protection IP 20 Ambient temperature 14 °F / -10 °C to +140 °F / +60 °C,Efficiency typ. 97 %, Protection index IP 20
Désignation du produitN° de référence
Tensiond'entrée V CC
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vdc
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
PVUC 24/24-10 24 24 10,00 57/127/179,5PVUC 24/24-20 24 24 20,00 57/127/179,5
AlimentationsPower supplies2
Courant de charge
Charging current
3.0 A max.
84Sujet à modificationSubject to change
Câble de communication / Prise femelleCommunication cable / Female plugPC-KOK1 / PC-CON1
AVANTAGES BENEFITS
PC-KOK1: Cable adaptateur avecconnecteur femelle pour RS2329 pôles Sub-D
PC-CON1: Prise femelle, 4 pôles
PC-KOK1: Adapter cable with femaleplug for RS232 9-pole Sub-D
PC-CON1: Female plug, 4-pole
APPLICATIONS APPLICATIONS
Pour tous les modèles Power Compact,qui ont intégré l’interface.
For all Power Compact models thathave integrated interface.
DONNÉES TECHNIQUES TECHNICAL DATA
Désignation du produitN° de référenceProduct NameOrder No.PC-KOK1PC-CON1
Câble de communication / Prise femelle /Convertisseur USBCommunication cable / Female plug / USB converterPV-KOK 2 / PV-CON / PV-USB/SERIELL
AVANTAGES BENEFITS
PV-KOK2: Cable adaptateur avecconnecteur femelle pour RS2329 pôles Sub-D
PV-CON: Prise femelle, 8 pôles
PV-USB/SERIELL: Convertisseur USBpour connecter des périphériques série(RS232 à 9 broches Sub-D) sur unport bus USB
PV-KOK2: Adapter cable with femaleplug for RS232 9-pole Sub-D
PV-CON: Female plug, 8-pole
PV-USB/SERIELL: USB converter toconnect serial devices (RS232 9-pinSub-D) to the USB bus
APPLICATIONS APPLICATIONS
Pour tous les modèles Power Vision,qui ont intégré l’interface.
For all Power Vision models that haveintegrated interface.
DONNÉES TECHNIQUES TECHNICAL DATA
Désignation du produitN° de référenceProduct NameOrder No.PV-KOK2PV-CONPV-USB/SERIELL
AlimentationsPower supplies 2
85Sujet à modification
Subject to change
Aperçu alimentations non régulées Overview transformer power supplies non-stabilized
Type Tens
ion
nom
inal
e d’
entr
éeRa
ted
inpu
t vol
tage
Tens
ion
de s
ortie
nom
inal
eRa
ted
outp
ut v
olta
ge
6 W 12 W
24 W
36 W
48 W
60 W
72 W
96 W
120 W
180 W
240 W
360 W
480 W
720 W
960 W
1200
W
GNC 230GNC 230GNC 230 / 400 V ± 15 V 24 V 2.5 A 5 A 7.5 A 10 A 15 A5 A 7.5 A 10 A 15 A5 A 7.5 A 10 A 15 A5 A 7.5 A 10 A 15 A
DCT 230 VDCT 230 VDCT 230 VDCT 230 V12 V 0.5 A 1 A 2 A 4 A12 V 0.5 A 1 A 2 A 4 A12 V 0.5 A 1 A 2 A 4 A12 V 0.5 A 1 A 2 A 4 A12 V 0.5 A 1 A 2 A 4 A12 V 0.5 A 1 A 2 A 4 A12 V 0.5 A 1 A 2 A 4 A12 V 0.5 A 1 A 2 A 4 A
24 V 0.5 A 1.5 A 2.5 A24 V 0.5 A 1.5 A 2.5 A24 V 0.5 A 1.5 A 2.5 A24 V 0.5 A 1.5 A 2.5 A24 V 0.5 A 1.5 A 2.5 A24 V 0.5 A 1.5 A 2.5 A24 V 0.5 A 1.5 A 2.5 A24 V 0.5 A 1.5 A 2.5 A24 V 0.5 A 1.5 A 2.5 A
GLC230 V
24 V1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A
400 V 1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A1 A 2 A 3 A 5 A 7.5 A 10 A
DNCDelta connection: 3 x 230 Vac (±11 V)
24 V4 A 10 A 15 A 20 A 30 A 40 A 50 A10 A 15 A 20 A 30 A 40 A 50 A10 A 15 A 20 A 30 A 40 A 50 A10 A 15 A 20 A 30 A 40 A 50 A10 A 15 A 20 A 30 A 40 A 50 A10 A 15 A 20 A 30 A 40 A 50 A
Star connection: 3 x 400 Vac (±20 V) 4 A 10 A 15 A 20 A 30 A 40 A 50 A10 A 15 A 20 A 30 A 40 A 50 A10 A 15 A 20 A 30 A 40 A 50 A10 A 15 A 20 A 30 A 40 A 50 A10 A 15 A 20 A 30 A 40 A 50 A10 A 15 A 20 A 30 A 40 A 50 A
Outre notre service de livraison sous 24 h, découvrez notre gamme de produits standard. Pour plus d’informations, n’hésitez pas à consulter notre site block.eu.
In addition to our 24 hours BLOCK direct sales program an overview of the entire standard range. For more information see block.eu.
AlimentationsPower supplies2
86Sujet à modificationSubject to change
Alimentation CC monophasée redressée et filtréeSingle-phase, non-stabilized DC power supplyDCT
J 1
AVANTAGES BENEFITS
Fusible thermique en entrée et fusiblede protection en sortie
Enroulement séparés
Accessoires de condensateur
Protection durable contre la corrosion,degré d’isolation élevé et fiabilitéélectrique maximale par encapsulationintégrale de résine synthétiqueXtraDenseFill
Thermal fuse in the input and a fuseprotection for the output
Separate windings
Capacitor switching at the output
Permanent corrosion protection, highinsulation value and maximum electricalreliability due to XtraDenseFill resinencapsulation
APPLICATIONS APPLICATIONS
Alimentation CC robuste axée sur lestâches principales de l’alimentationen tension et en courant. Profil deposition plat optimisé pour les coffretsde distribution de l’immotique.
Robust DC power supply isconcentrated on the core task ofvoltage and power supply. Flat stepprofile optimized for installation incontrol panels in building automation.
DONNÉES TECHNIQUES TECHNICAL DATA
Ondulation résiduelle Ð5 %, Température ambiante +25 °C, Indice de protectionIP 00 Residual ripple factor Ð5 %, Ambient temperature 77 °F / +25 °C,Protection index IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
DCT 12-0,5 230 12 0,50 94/63/71DCT 12-1 230 12 1,00 94/63/71DCT 12-2 230 12 2,00 94/63/106DCT 12-4 230 12 4,00 94/63/159DCT 24-0,5 230 24 0,50 94/63/71DCT 24-1,5 230 24 1,50 94/63/106DCT 24-2,5 230 24 2,50 94/63/159
Alimentation CC monophasée redressée et filtréeSingle-phase, non-stabilized DC power supplyGLC
T J 1
AVANTAGES BENEFITS
Fusible de protection en entrée et ensortie
Enroulements séparés
Circuit de condensateurs en sortie
Borne double en sortie
Signalisation CC OK par LED
Fuse protection in the input and a fuseprotection for the output
Separate windings
Capacitor switching at the output
Double screw terminals on the output
DC OK signaling via LEDs
APPLICATIONS APPLICATIONS
Alimentation CC robuste axée sur lestâches principales de l’alimentation entension et en courant.
Robust DC power supply isconcentrated on the core task ofvoltage and power supply.
DONNÉES TECHNIQUES TECHNICAL DATA
Ondulation résiduelle Ð5 %, Température ambiante +60 °C, Indice de protectionIP 00 Residual ripple factor Ð5 %, Ambient temperature 140 °F /+60 °C,Protection index IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
GLC 230/24-1 230 24 1,00 85/116/62,5GLC 230/24-2 230 24 2,00 85/138/90GLC 230/24-3 230 24 3,00 85/138/90GLC 230/24-5 230 24 5,00 134/175/125GLC 230/24-7,5 230 24 7,50 155/212/175GLC 230/24-10 230 24 10,00 155/212/175GLC 400/24-1 400 24 1,00 85/130/65,5GLC 400/24-2 400 24 2,00 85/138/90GLC 400/24-3 400 24 3,00 85/138/90GLC 400/24-5 400 24 5,00 134/175/125GLC 400/24-7,5 400 24 7,50 155/212/175GLC 400/24-10 400 24 10,00 155/212/175
AlimentationsPower supplies 2
87Sujet à modification
Subject to change
Alimentation CC monophasée redressée et filtréeSingle-phase, non stabilized DC power supplyGNC
T J 2
AVANTAGES BENEFITS
Insensibilité aux surtensions etphénomènes transitoires
Capacité de surcharge élevée
Signalisation CC OK par LED
Circuit de condensateurs en sortie
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Protection en sortie aveccondensateurs MKT
GNC 24-2,5: avec semelle combinéepour un montage à vis et sur rail DIN
Unsusceptible to voltage surges ortransients
High overload capacity
DC OK signaling via LEDs
Capacitor switching at the output
Very good corrosion protection and lownoise due to vacuum impregnation
Impulse loading MKT-capacitors
GNC 24-2,5 with combination footplatefor bolted and DIN rail mounting
APPLICATIONS APPLICATIONS
Alimentation CC robuste pour uneutilisation dans des conditionsindustrielles difficiles.
Robust DC power supply for harshindustrial applications.
DONNÉES TECHNIQUES TECHNICAL DATA
Ondulation résiduelle Ð3 %, Température ambiante +60 °C, Indice de protectionIP 00 Residual ripple factor Ð3 %, Ambient temperature 140 °F / +60 °C,Protection index IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
GNC 24-2,5 230/400, ±15 24 2,50 76/140/84GNC 24-5 230/400, ±15 24 5,00 103/160/105GNC 24-7,5 230/400, ±15 24 7,50 112/173/120GNC 24-10 230/400, ±15 24 10,00 121/173/120GNC 24-15 230/400, ±15 24 15,00 112/200/90
Alimentation CC triphasée redressée et filtréeThree-phase, non stabilized DC power supplyDNC
T J 2
AVANTAGES BENEFITS
Insensibilité aux surtensions etphénomènes transitoires
Capacité de surcharge élevée
Signalisation CC OK par LED
Circuit de condensateurs en sortie
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Protection en sortie aveccondensateurs MKT
Unsusceptible to voltage surges ortransients
High overload capacity
DC OK signaling via LEDs
Capacitor switching at the output
Very good corrosion protection and lownoise due to vacuum impregnation
Impulse loading MKT-capacitors
APPLICATIONS APPLICATIONS
Alimentation CC robuste pour uneutilisation dans des conditionsindustrielles difficiles.
Robust DC power supply for harshindustrial applications.
DONNÉES TECHNIQUES TECHNICAL DATA
Ondulation résiduelle Ð2 %, Température ambiante +60 °C, Indice de protectionIP 00 Residual ripple factor Ð2 %, Ambient temperature 140 °F / +60 °C,Protection index IP 00
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
DNC 24-4 Connexionen triangle:3x219/230/241Connexion en étoile:3x380/400/420
24 4,00 130/160/130
DNC 24-10 Connexionen triangle:3x219/230/241Connexion en étoile:3x380/400/420
24 10,00 165/190/164
DNC 24-15 C Connexionen triangle:3x219/230/241Connexion en étoile:3x380/400/420
24 15,00 165/190/164
DNC 24-20 C Connexionen triangle:3x219/230/241Connexion en étoile:3x380/400/420
24 20,00 175/225/216
DNC 24-30 C Connexionen triangle:3x219/230/241Connexion en étoile:3x380/400/420
24 30,00 175/225/216
AlimentationsPower supplies2
88Sujet à modificationSubject to change
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie V CC
Courantde sortie A
DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage Vdc
OutputCurrent A
DimensionsW/H/D in mm
DNC 24-40 C Connexionen triangle:3x219/230/241Connexion en étoile:3x380/400/420
24 40,00 225/297/266
DNC 24-50 C Connexionen triangle:3x219/230/241Connexion en étoile:3x380/400/420
24 50,00 225/297/266
AlimentationsPower supplies 2
89Sujet à modification
Subject to change
Transformateurs Transformers
AlimentationsPower supplies2Inductances/Filtres CEMReactors/EMI filters3
NouveautésNews0
ü Inductances de ligne Line reactors ü Inductances pour circuit de filtrage Detuned reactors ü Filtres anti-harmoniques Harmonic filters ü Filtres d’antiparasitage Radio interference suppression filtersü Stabilisateurs de tension Voltage stabilizersü Inductances moteur Motor reactorsü Filtres sinus Sine filtersü Tests CEM EMC testsü Essais de matériaux Material testsü Tests climatiques Environmental simulations
1
90Sujet à modificationSubject to change
3
91
Aperçu des inductances de ligne Overview line reactors
avec bobine de réactance triphasée with three-phase reactor
sans bobine de réactance triphasée without three-phase reactor
Courant de ligne Line current
Inductances/Filtres CEMReactors/EMI filters3
Type Tens
ion
nom
inal
e d’
entr
éeRa
ted
inpu
t vol
tage
Chut
e de
tens
ion
(uk)
Shor
t-circ
uit v
olta
ge (u
k)
Courant nominal (A)Rated current (A)
NKE 230 / 400NKE 230 / 400NKE 230 / 400 V 2 – 4V 2 – 4 % 4 6 10 16 20 25% 4 6 10 16 20 25% 4 6 10 16 20 25% 4 6 10 16 20 25% 4 6 10 16 20 25% 4 6 10 16 20 25% 4 6 10 16 20 25% 4 6 10 16 20 25% 4 6 10 16 20 25% 4 6 10 16 20 25% 4 6 10 16 20 25
LR3-A 3 x 400 V 4 % 4 64 6 8 10 16 20 2516 20 2516 20 25 30 35 40 45 50 63 8030 35 40 45 50 63 8030 35 40 45 50 63 8030 35 40 45 50 63 8030 35 40 45 50 63 8030 35 40 45 50 63 8030 35 40 45 50 63 8030 35 40 45 50 63 8030 35 40 45 50 63 80
LR3 3 x 400 – 480LR3 3 x 400 – 480LR3 3 x 400 – 480 V 3 – 5V 3 – 5 % 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90% 2 4 6 8 10 16 20 25 30 35 40 45 50 63 70 80 90
LR3A 3 x 400 – 500LR3A 3 x 400 – 500LR3A 3 x 400 – 500 V 3 – 5V 3 – 5 % 90
TypeCourant nominal (A)Rated current (A)
NKE
LR3-A
LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600
LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600LR3A 100 115 125 160 180 200 250 300 400 500 630 710 800 1000 1200 1400 1600
Outre notre service de livraison sous 24 h, découvrez notre gamme de produits standard. Pour plus d’informations, n’hésitez pas à consulter notre site block.eu.
In addition to our 24 hours BLOCK direct sales program an overview of the entire standard range. For more information see block.eu.
92Sujet à modificationSubject to change
Inductance de ligne, monophaséeLine reactor, single-phaseNKE 230 / 400
W J ß
AVANTAGES BENEFITS
Utilisable comme réactance de ligne,inductance de commutation, réactanceCPR
Atténuation des harmoniques decourant
Limitation du courant de démarrage
Augmentation de la durée de vie pourles consommateurs
Ondulation réduite
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Tenue aux coupures du réseau
Limitation du courant de crête
Use as line reactor, commutatingreactor or PFC reactor
Power harmonic damping
Starting current limitation
Increases the service life of equipment
Low ripple
Very good corrosion protection and lownoise due to vacuum impregnation
Bridging voltage dips
Peak current limitation
APPLICATIONS APPLICATIONS
Bobine de réactance à courant deréseau conçue pour minimiser le bruitde ligne, réduire les parts de puissanceréactive et les courants de chargedans le condensateur DC-Link ainsi quepour améliorer le facteur de puissance.
Line reactor to minimize line noise, toreduce the reactive-power componentsand charging currents in the DC linkcapacitor and to improve the powerfactor.
DONNÉES TECHNIQUES TECHNICAL DATA
Courant assigné 4 - 25 A, Température ambiante de -10 °C à +40 °C, Indice deprotection IP 00 Rated current 4 to 25 A, Ambient temperature 14 °F / -10 °Cto +104 °F / +40 °C, Degree of protection IP 00
Désignation duproduitN° de référence
Tensionnominale Vac
Courantnominal A
Inductance mH DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
RatedCurrent A
Inductivity mH DimensionsW/H/D in mm
NKE 4/7,33 230 4 7,330 66/68/60NKE 4/12,75 400 4 12,750 66/68/60NKE 6/4,88 230 6 4,880 66/68/60NKE 6/8,50 400 6 8,500 78/96/84NKE 10/2,93 230 10 2,930 78/96/84NKE 10/5,10 400 10 5,100 78/96/84NKE 16/1,83 230 16 1,830 78/96/84NKE 16/3,19 400 16 3,190 88/110/96NKE 20/1,47 230 20 1,470 87/96/84NKE 20/2,55 400 20 2,550 110/130/120NKE 25/1,17 230 25 1,170 87/96/84NKE 25/2,04 400 25 2,040 110/130/120
Inductance de ligne, triphaséeLine reactor, three-phaseLR3-A
W J
AVANTAGES BENEFITS
Utilisable comme réactance de ligne,inductance de commutation, réactanceCPR
Garantie d’une tension de court-circuitde 4 % sur le réseau
Limitation du courant de démarrage
Augmentation de la durée de vie pourles consommateurs
Ondulation réduite
Tenue aux coupures du réseau
Limitation du courant de crête
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Anneaux de levage intégrés
Use as line reactor, commutatingreactor or PFC reactor
Ensuring the short-circuit voltage of4 % to the mains
Starting current limitation
Increases the service life of equipment
Low ripple
Bridging voltage dips
Peak current limitation
Very good corrosion protection and lownoise due to vacuum impregnation
Multifunctional fixing rails
APPLICATIONS APPLICATIONS
Bobine de réactance à courant deréseau conçue pour minimiser le bruitde ligne, réduire les parts de puissanceréactive et les courants de chargedans le condensateur DC-Link ainsi quepour améliorer le facteur de puissance.
Line reactor to minimize line noise, toreduce the reactive-power componentsand charging currents in the DC linkcapacitor and to improve the powerfactor.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation H, Température ambiante +40 °C, Indice de protection IP 00 Insulation class H, Ambient temperature +104 °F / +40 °C, Degree of protectionIP 00
Désignation duproduitN° de référence
Tensionnominale Vac
Courantnominal A
Inductance mH DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
RatedCurrent A
Inductivity mH DimensionsW/H/D in mm
LR3-AD004-404-0 3 x 400 3 x 4 7,350 96/117/56LR3-AD006-404-0 3 x 400 3 x 6 4,900 96/117/69LR3-AD008-404-0 3 x 400 3 x 8 3,680 120/137/85LR3-AD010-404-0 3 x 400 3 x 10 2,940 120/137/85LR3-AD016-404-0 3 x 400 3 x 16 1,840 150/165/95LR3-AD020-404-0 3 x 400 3 x 20 1,470 150/165/95LR3-AD025-404-0 3 x 400 3 x 25 1,180 155/165/110LR3-AD030-404-0 3 x 400 3 x 30 0,980 155/170/110LR3-AD035-404-0 3 x 400 3 x 35 0,840 155/170/110LR3-AD040-404-0 3 x 400 3 x 40 0,730 185/198/102LR3-AD045-404-0 3 x 400 3 x 45 0,650 185/198/112LR3-AD050-404-0 3 x 400 3 x 50 0,590 185/198/112LR3-AD063-404-0 3 x 400 3 x 63 0,470 210/235/117LR3-AD080-404-0 3 x 400 3 x 80 0,370 210/240/125
Inductances/Filtres CEMReactors/EMI filters 3
93Sujet à modification
Subject to change
Inductance de ligne, triphaséeLine reactor, three-phaseLR3 400
W J ß
AVANTAGES BENEFITS
Utilisable comme réactance de ligne,inductance de commutation, réactanceCPR
Garantie d’une tension de court-circuitde 3, 4 ou 5 % sur le réseau
Limitation du courant de démarrage
Augmentation de la durée de vie pourles consommateurs
Ondulation réduite
Tenue aux coupures du réseau
Limitation du courant de crête
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Anneaux de levage intégrés
Use as line reactor, commutatingreactor or PFC reactor
Ensuring the short-circuit voltage of 3,4 or 5 % to the mains
Starting current limitation
Increases the service life of equipment
Low ripple
Bridging voltage dips
Peak current limitation
Very good corrosion protection and lownoise due to vacuum impregnation
Integrated lifting rings
APPLICATIONS APPLICATIONS
Bobine de réactance à courant deréseau conçue pour minimiser le bruitde ligne, réduire les parts de puissanceréactive et les courants de chargedans le condensateur DC-Link ainsi quepour améliorer le facteur de puissance.
Line reactor to minimize line noise, toreduce the reactive-power componentsand charging currents in the DC linkcapacitor and to improve the powerfactor.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation B, F ou H, Température ambiante de -10 °C à +40 °C, Indice deprotection IP 00 Insulation class B, F or H, Ambient temperature 14 °F / -10 °Cto +104 °F / +40 °C, Degree of protection IP 00
Désignation duproduitN° de référence
Tensionnominale Vac
Courantnominal A
Inductance mH DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
RatedCurrent A
Inductivity mH DimensionsW/H/D in mm
LR3 40-4/2 3 x 400 3 x 2 14,700 74/116/56LR3 40-4/4 3 x 400 3 x 4 7,350 80/116/60LR3 40-4/6 3 x 400 3 x 6 4,900 80/116/69LR3 40-4/8 3 x 400 3 x 8 3,680 120/135/85LR3 40-4/10 3 x 400 3 x 10 2,940 120/135/85LR3 40-4/16 3 x 400 3 x 16 1,840 120/135/95LR3 40-4/20 3 x 400 3 x 20 1,470 155/162/95LR3 40-4/25 3 x 400 3 x 25 1,180 155/167/110LR3 40-4/30 3 x 400 3 x 30 0,980 155/167/110LR3 40-4/35 3 x 400 3 x 35 0,840 155/166/110LR3 40-4/40 3 x 400 3 x 40 0,740 185/195/102LR3 40-4/45 3 x 400 3 x 45 0,650 185/196/112
Désignation duproduitN° de référence
Tensionnominale Vac
Courantnominal A
Inductance mH DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
RatedCurrent A
Inductivity mH DimensionsW/H/D in mm
LR3 40-4/50 3 x 400 3 x 50 0,590 185/207/112LR3 40-4/63 3 x 400 3 x 63 0,470 210/241/117LR3 40-4/70 3 x 400 3 x 70 0,420 210/240/117LR3 40-4/80 3 x 400 3 x 80 0,370 210/238/125LR3 40-4/90 3 x 400 3 x 90 0,330 267/201/115LR3 40-4/100 3 x 400 3 x 100 0,300 267/201/139LR3 40-4/115 3 x 400 3 x 115 0,260 291/212/139LR3 40-4/125 3 x 400 3 x 125 0,240 291/211/139LR3 40-4/160 3 x 400 3 x 160 0,190 291/210/149LR3 40-4/180 3 x 400 3 x 180 0,170 291/212/153LR3 40-4/200 3 x 400 3 x 200 0,150 352/264/144LR3 40-4/250 3 x 400 3 x 250 0,120 352/265/158LR3 40-4/300 3 x 400 3 x 300 0,098 352/265/168LR3 40-4/400 3 x 400 3 x 400 0,074 352/266/183LR3 40-4/500 3 x 400 3 x 500 0,059 352/266/195LR3 40-4/630 3 x 400 3 x 630 0,047 412/317/188LR3 40-4/710 3 x 400 3 x 710 0,042 480/372/186LR3 40-4/800 3 x 400 3 x 800 0,037 480/371/200LR3 40-4/1000 3 x 400 3 x 1000 0,030 480/376/245LR3 40-4/1200 3 x 400 3 x 1200 0,025 552/419/244LR3 40-4/1400 3 x 400 3 x 1400 0,021 552/420/274LR3 40-4/1600 3 x 400 3 x 1600 0,019 552/416/294
Inductances/Filtres CEMReactors/EMI filters3
94Sujet à modificationSubject to change
Inductance de ligne, triphasée, aluminiumLine reactor, three-phase, aluminiumLR3A 400
W J ß
AVANTAGES BENEFITS
Utilisable comme réactance de ligne,inductance de commutation, réactanceCPR
Poids réduit grâce à l’enroulement enaluminium
Garantie d’une tension de court-circuitde 3, 4 ou 5 % sur le réseau
Limitation du courant de démarrage
Augmentation de la durée de vie pourles consommateurs
Ondulation réduite
Tenue aux coupures du réseau
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Use as line reactor, commutatingreactor or PFC reactor
Weight reduction through aluminumwinding
Ensuring the short-circuit voltage of 3,4 or 5 % to the mains
Starting current limitation
Increases the service life of equipment
Low ripple
Bridging voltage dips
Peak current limitation
Very good corrosion protection and lownoise due to vacuum impregnation
APPLICATIONS APPLICATIONS
Bobine de réactance à courant deréseau conçue pour minimiser lesrétroactions secteur, réduire les partsde puissance réactive et les courantsde charge dans le condensateur DC-Link ainsi que pour améliorer la valeurcos(phi).
Line reactor to minimize mainspollution, to reduce the reactive-powercomponents and charging currents inthe DC link capacitor and to improvethe cos(phi).
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation H, Température ambiante de -10 °C à +40 °C, Indice deprotection IP 00 Insulation class H, Ambient temperature 14 °F / -10 °C to+104 °F / +40 °C, Degree of protection IP 00
Désignation duproduitN° de référence
Tensionnominale Vac
Courantnominal A
Inductance mH DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
RatedCurrent A
Inductivity mH DimensionsW/H/D in mm
LR3A 40-4/90 3 x 400 90 0,330 267/200/149LR3A 40-4/100 3 x 400 100 0,290 267/200/173LR3A 40-4/115 3 x 400 115 0,250 291/210/179LR3A 40-4/125 3 x 400 125 0,230 291/210/179LR3A 40-4/160 3 x 400 160 0,180 291/210/189LR3A 40-4/180 3 x 400 180 0,160 265/230/157LR3A 40-4/200 3 x 400 200 0,150 352/260/194LR3A 40-4/250 3 x 400 250 0,120 352/265/180LR3A 40-4/300 3 x 400 300 0,089 352/260/219LR3A 40-4/400 3 x 400 400 0,074 352/260/234LR3A 40-4/500 3 x 400 500 0,059 352/260/245LR3A 40-4/630 3 x 400 630 0,047 480/380/225LR3A 40-4/710 3 x 400 710 0,042 480/380/235LR3A 40-4/800 3 x 400 800 0,037 480/380/250
Désignation duproduitN° de référence
Tensionnominale Vac
Courantnominal A
Inductance mH DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
RatedCurrent A
Inductivity mH DimensionsW/H/D in mm
LR3A 40-4/1000 3 x 400 1000 0,030 480/380/295LR3A 40-4/1200 3 x 400 1200 0,025 555/445/330LR3A 40-4/1400 3 x 400 1400 0,021 555/445/360LR3A 40-4/1600 3 x 400 1600 0,019 555/445/380
Inductances/Filtres CEMReactors/EMI filters 3
2 – 80 A bientôt disponible. 2 – 80 A coming soon.
95Sujet à modification
Subject to change
Inductance pour circuit de filtrageDetuned reactorDR3
W J ß
AVANTAGES BENEFITS
Aucune surcharge des condensateurs
Amélioration du comportementd’impédance
Tolérance d’inductance faible
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
Déroulement linéaire d’inductance quidépasse largement le courant assigné
Avec thermocontact en option
No overloading of the capacitors
Stabilizing mains impedance
Low inductance tolerance
Very good corrosion protection and lownoise due to vacuum impregnation
Extended linearity
Optional with thermal switch
APPLICATIONS APPLICATIONS
Inductance pour circuit de filtragepour le blocage des installations decompensation du courant réactif
Detuned reactor for choking idlereactive power compensationcapacitors.
DONNÉES TECHNIQUES TECHNICAL DATA
Classe d’isolation F/H, Température ambiante max. 40 °C, Type de protectionIP 00 Insulation class F/H, Maximum ambient temperature 104 °F/ 40 °C,Degree of protection IP 00
Désignation duproduitN° de référence
Tensionnominale Vac
Pour puissancereactive kVAr
Facteur defiltrage %
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
For ReactivePower kVAr
FilteredFactor %
DimensionsW/H/D in mm
DR3 12,5/7 3 x 400 12,5 p = 7 % 185/215/125DR3 12,5/14 3 x 400 12,5 p = 14 % 240/245/140DR3 25/7 3 x 400 25,0 p = 7 % 212/235/125DR3 25/14 3 x 400 25,0 p = 14 % 240/245/150DR3 50/7 3 x 400 50,0 p = 7 % 300/234/140DR3 50/14 3 x 400 50,0 p = 14 % 300/270/160
Filtre anti-harmoniqueHarmonic filterHF1P 230
J ß
AVANTAGES BENEFITS
Courant absorbé de forme sinusoïdaledu réseau pour des appareils avecredresseurs à diodes B2U noncontrôlés
Respect des normes EN 61000-3-2,EN 61000-3-12
Assistance pour le respect des normesIEEE 519, D-A-CH-CZ
Facteur de puissance élevé >0,95 auniveau du courant nominal
Fonctionnement possible à 50 - 60 Hz
Utilisation possible du HF1Pcomme filtre central pour plusieursconvertisseurs
Sinusoidal current consumption fromthe main in devices with uncontrolledB2U diode rectifiers
Compliance with EN 61000-3-2,EN 61000-3-12
Support in the compliance with IEEE519, D-A-CH-CZ
Power factor >0,95 at rated current
Operation at 50 - 60 Hz possible
Use of the HF1P as a central sum filterfor multiple converters possible
APPLICATIONS APPLICATIONS
Filtre anti-harmonique garantissantdes courants réseaux de formesinusoïdale, la réduction desparasites d’harmoniques sur secteur,l’augmentation de la durée de vie etde la fiabilité du système, ainsi quele respect des normes de qualité del’alimentation, telles que IEEE 519,61000-3-2 et IEC 61000-3-12.
Harmonic filter module to ensuresinusoidal main currents, reductionof main harmonic currents, increasein system service life and systemreliability and compliance with powerquality standards such as IEEE 519,TEC 61000-3-2, IEC 61000-3-12.
DONNÉES TECHNIQUES TECHNICAL DATA
THD-I: 10 % à 50 Hz, 18 % à 60 Hz en fonctionnement normal, Puissancenominale de la charge 0,19 - 5,7 kW, Classe d’isolation H, Température ambiantede -10 °C à +40 °C, Indice de protection IP 20 THD-I 10 % at 50 Hz, 18 % at60 Hz in rated operation, Load rated capacity 0.19 - 5.7 kW, Insulation class H,Ambient temperature 14 °F / -10 °C to +104 °F / +40 °C, Degree of protectionIP 20
Désignation duproduitN° de référence
Tensionnominale Vac
Plagede tension Vac
Courantnominal A
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
VoltageRange Vac
RatedCurrent A
DimensionsW/H/D in mm
HF1P 0,19-230 230 207-253 0,84 85/107/230HF1P 0,59-230 230 207-253 2,50 96/135/280HF1P 1,01-230 230 207-253 4,44 109/138/300HF1P 2,73-230 230 207-253 11,90 132/182/385HF1P 3,68-230 230 207-253 16,00 160/239/401HF1P 4,60-230 230 207-253 20,00 144/210/444HF1P 5,70-230 230 207-253 25,00 160/242/531
Inductances/Filtres CEMReactors/EMI filters3
96Sujet à modificationSubject to change
avec filtre with filtersans filtre without filter
courant de ligne line current
THD(i)The THD (i) without the filter, dependent on the impedance of the main and is bet-ween 100 % and 200 % at nominal load.With filter <8 % at nominal load.
Inductances/Filtres CEMReactors/EMI filters 3
Filtre anti-harmoniqueHarmonic filterHF1K 400
W J ß
AVANTAGES BENEFITS
Courant absorbé de forme sinusoïdaledu réseau pour des appareils avecredresseurs à diodes B6U noncontrôlés
Respect des normes EN 61000-3-2,EN 61000-3-12
Assistance pour le respect des normesIEEE 519, D-A-CH-CZ
Cos(phi)>0,95 au niveau du courantnominal
Face à une bobine de réactanceà courant de réseau de 4 % uk,les chutes de tension de circuitintermédiaire sont négligeables
Filtre anti-harmonique avec unepuissance réactive à vide minimalecapacitative
Fonctionnement possible à 50 - 60 Hz
Sinusoidal current consumption fromthe main in devices with uncontrolledB6U diode rectifiers
Compliance with EN 61000-3-2,EN 61000-3-12
Support in the compliance with IEEE519, D-A-CH-CZ
Power factor >0,95 at rated current
Hardly any intermediate circuit voltagedip by comparison with a 4 % uK linereactor
Harmonic filter with minimumcapacitive idle reactive power
Operation at 50 - 60 Hz possible
APPLICATIONS APPLICATIONS
Filtre anti-harmonique garantissantdes courants réseaux de formesinusoïdale, la réduction desparasites d’harmoniques sur secteur,l’augmentation de la durée de vie etde la fiabilité du système, ainsi quele respect des normes de qualité del’alimentation, telles que IEEE 519,61000-3-2 et IEC 61000-3-12.
Harmonic filter module to ensuresinusoidal main currents, reductionof main harmonic currents, increasein system service life and systemreliability and compliance with powerquality standards such as IEEE 519,TEC 61000-3-2, IEC 61000-3-12.
DONNÉES TECHNIQUES TECHNICAL DATA
THD-I: <8 % en fonctionnement normal, Puissance nominale de la charge 5,5 -90 kW, Classe d’isolation H, Température ambiante de -10 °C à +45 °C, Indicede protection IP 00 THD-I <8 % in rated operation, Load rated capacity 5.5 -90 kW, Insulation class H, Ambient temperature 14 °F / -10 °C to 113 °F /+45 °C, Degree of protection IP 00
Désignation duproduitN° de référence
Tensionnominale Vac
Plagede tension Vac
Courantnominal A
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
VoltageRange Vac
RatedCurrent A
DimensionsW/H/D in mm
HF1K 7-400 3 x 400 360-440 3 x 10 375/235/236HF1K 13-400 3 x 400 360-440 3 x 19 440/275/275HF1K 18-400 3 x 400 360-440 3 x 26 440/275/285HF1K 24-400 3 x 400 360-440 3 x 35 485/315/290HF1K 30-400 3 x 400 360-440 3 x 43 545/355/290HF1K 50-400 3 x 400 360-440 3 x 73 545/315/320HF1K 70-400 3 x 400 360-440 3 x 101 685/420/348HF1K 100-400 3 x 400 360-440 3 x 144 685/430/375
AVANTAGES BENEFITS
APPLICATIONS APPLICATIONS
DONNÉES TECHNIQUES TECHNICAL DATA
Désignation duproduitN° de référence
Tensionnominale Vac
Plagede tension Vac
Courantnominal A
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
VoltageRange Vac
RatedCurrent A
DimensionsW/H/D in mm
97Sujet à modification
Subject to change
Aperçu des filtres d’antiparasitage Overview RFI filters
valeur limite de crête limit maximum value
valeur limite moyenne limit mean value
courbe de la valeur de crête mesurée measurement maximum value gradient
courbe de la valeur moyenne mesurée measurement mean value gradient
Émissions par conduction conducted emission
Inductances/Filtres CEMReactors/EMI filters3
TypeType Pert
urba
tions
bas
se fr
éque
nce
(=LF
) ou
haut
e fré
quen
ce (=
HF)
Low
freq
uenc
y dis
turb
ance
(=LF
) or h
igh
freq
uenc
y (=H
F)
Cour
ant d
e fu
ite ré
duit
Low
leak
age
curr
ent
Faibl
e co
uran
t de
fuite
Re
duce
d le
akag
e cu
rren
t
Rése
au IT
IT
mai
ns
Mat
ériel
élec
tron
ique
Elec
tron
ic ap
para
ture
s
Appli
catio
ns g
énér
ales
Gene
ral r
equi
rem
ents
Inst
allat
ions
tech
nique
s, fa
ibles
per
turb
ation
s Sy
stem
s en
gine
erin
g, w
eak i
nter
fere
nces
Inst
allat
ions
tech
nique
s, co
nstr
uctio
ns c
omple
xes
Syst
ems
engi
neer
ing,
com
plex
str
uctu
re
Varia
teur
de fr
éque
nce,
gran
des l
ongu
eurs
de câ
bles d
e mot
eurs
Freq
uenc
y inv
erte
r, lo
ng m
otor
cab
le
Varia
teur
de fr
éque
nce,
faibl
es lo
ngue
urs d
e câb
les de
mot
eurs
Freq
uenc
y inv
erte
r, sh
ort m
otor
cab
le
Plus
ieurs
varia
teur
s de
fréq
uenc
e Se
vera
l fre
quen
cy in
vert
ers
Récu
péra
tion
d‘éne
rgie
Mai
ns fe
edba
ck
Mon
opha
sé, C
A AC
sin
gle-
phha
seAC
sin
gle-
phha
seAC
sin
gle-
phha
seAC
sin
gle-
phha
seAC
sin
gle-
phha
seAC
sin
gle-
phha
seAC
sin
gle-
phha
seAC
sin
gle-
phha
seAC
sin
gle-
phha
se
HFE 156 HFHFE 156 HFHFE 156 HF r r r rr r rr r r r r rr r rr r r
HFE 356 HFHFE 356 HFHFE 356 HF r r r rr r rr r r r rr r
HFE 104 HFHFE 104 HFHFE 104 HF r r r rr r rr r r
HFE 200 HFHFE 200 HFHFE 200 HF r r r rr r rr r r
HLE 110 HFHLE 110 HFHLE 110 HF r r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r r
HLE 310 HFHLE 310 HFHLE 310 HF r r r rr r rr r r r r
Trip
hasé
, CA
AC th
ree-
phas
eAC
thre
e-ph
ase
AC th
ree-
phas
eAC
thre
e-ph
ase
AC th
ree-
phas
eAC
thre
e-ph
ase
AC th
ree-
phas
eAC
thre
e-ph
ase
HFD 156 HFHFD 156 HFHFD 156 HF r r r rr r rr r r r rr r
HFD 356 HFHFD 356 HFHFD 356 HF r r r rr r rr r r r rr r
HLD 103 HFHLD 103 HFHLD 103 HF r r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r r
HLD 110 HFHLD 110 HFHLD 110 HF r r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r r
HLD 310 HFHLD 310 HFHLD 310 HF r r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r r r rr r
HLD 710 HFHLD 710 HFHLD 710 HF r r r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r r
HLD 810 HFHLD 810 HFHLD 810 HF r r r r rr r r rr r r rr r r r r r
HFD 500 HFHFD 500 HFHFD 500 HF r r rr r rr r r r rr r
HFD 210 HFHFD 210 HFHFD 210 HF r r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r r
HFD 510 HFHFD 510 HFHFD 510 HF r r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r rr r r r r r r
Trip
hasé
+ N
, CA
AC th
ree-
phas
e +
NAC
thre
e-ph
ase
+ N
AC th
ree-
phas
e +
NAC
thre
e-ph
ase
+ N
AC th
ree-
phas
e +
NAC
thre
e-ph
ase
+ N
AC th
ree-
phas
e +
NAC
thre
e-ph
ase
+ N
AC th
ree-
phas
e +
NAC
thre
e-ph
ase
+ N HLV 110 HFHLV 110 HFHLV 110 HF r r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r r
HLV 310 HFHLV 310 HFHLV 310 HF r r r rr r rr r r r r
HLV 710 HFHLV 710 HFHLV 710 HF r r r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r r
HLV 810 HFHLV 810 HFHLV 810 HF r r r r rr r r rr r r rr r r r r r
HFV 510 HFHFV 510 HFHFV 510 HF r r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r rr r r r r r r r
Outre notre service de livraison sous 24 h, découvrez notre gamme de produits standard. Pour plus d’informations, n’hésitez pas à consulter notre site block.eu.
In addition to our 24 hours BLOCK direct sales program an overview of the entire standard range. For more information see block.eu.
98Sujet à modificationSubject to change
Filtre d’antiparasitage, monophaséRadio interference suppression filter, single-phaseHFE 156
J
AVANTAGES BENEFITS
Pour la suppression générale desinterférences électromagnétiques
Concept de filtre à un étage
Filtrage efficace des émissionsparasites liées aux câbles
Augmentation de l’immunité auxparasites des consommateursraccordés
Montage sur rail DIN
For general EMI suppression
Single-stage filter concept
Efficient filter effect against line-boundinterference emissions
Increase in the interference immunityof the connected equipment
DIN rail mounting
APPLICATIONS APPLICATIONS
Filtre d’antiparasitage pour lasuppression des parasites côtésecteur des alimentations et appareilsélectroniques.
Radio interference suppressionfilter for mains-side interferencesuppression of power supplies andelectronic devices.
DONNÉES TECHNIQUES TECHNICAL DATA
Courant de fuite 8 mA, Température ambiante max. 45 °C, Indice de protectionIP 20 Leakage current 8.00 mA, Ambient temperature max. 113 °F / 45 °C,Degree of protection IP 20
Désignation duproduitN° de référence
Tensionnominale Vac
Plagede tension Vac
Courantnominal A
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
VoltageRange Vac
RatedCurrent A
DimensionsW/H/D in mm
HFE 156-230/1 250 0 - 250 1 40/85/107HFE 156-230/3 250 0 - 250 3 40/85/107HFE 156-230/6 250 0 - 250 6 40/85/107HFE 156-230/10 250 0 - 250 10 40/85/107HFE 156-230/12 250 0 - 250 12 45/110/127HFE 156-230/16 250 0 - 250 16 45/110/127
Filtre d’antiparasitage, triphaséRadio interference suppression filter, three-phaseHFD 156
J
AVANTAGES BENEFITS
Pour la suppression générale desinterférences électromagnétiques
Concept de filtre à un étage
Filtrage efficace des émissionsparasites liées aux câbles
Augmentation de l’immunité auxparasites des consommateursraccordés
Montage sur rail DIN
For general EMI suppression
Single-stage filter concept
Efficient filter effect against line-boundinterference emissions
Increase in the interference immunityof the connected equipment
DIN rail mounting
APPLICATIONS APPLICATIONS
Filtre d’antiparasitage pour lasuppression des parasites côtésecteur des alimentations et appareilsélectroniques.
Radio interference suppressionfilter for mains-side interferencesuppression of power supplies andelectronic devices.
DONNÉES TECHNIQUES TECHNICAL DATA
Courant de fuite 1,00 mA, Température ambiante max. 45 °C, Indice de protectionIP 20 Leakage current 1.00 mA, Ambient temperature max. 113 °F / 45 °C,Degree of protection IP 20
Désignation duproduitN° de référence
Tensionnominale Vac
Plagede tension Vac
Courantnominal A
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
VoltageRange Vac
RatedCurrent A
DimensionsW/H/D in mm
HFD 156-400/3 3 x 480 3 x 0 - 480 3 x 3 45/110/127HFD 156-400/6 3 x 480 3 x 0 - 480 3 x 6 45/110/127HFD 156-400/10 3 x 480 3 x 0 - 480 3 x 10 45/110/127HFD 156-400/12 3 x 480 3 x 0 - 480 3 x 12 45/140/147HFD 156-400/16 3 x 480 3 x 0 - 480 3 x 16 45/140/147
Inductances/Filtres CEMReactors/EMI filters 3
99Sujet à modification
Subject to change
Filtre d’antiparasitage, triphaséRadio interference suppression filter, three-phaseHLD 103
J
AVANTAGES BENEFITS
Pour une suppression améliorée desinterférences électromagnétiques
Concept de filtre à un étage
Filtrage efficace des émissionsparasites liées aux câbles
Augmentation de l’immunité auxparasites des consommateursraccordés
For enhanced EMI suppression
Single-stage filter concept
Efficient filter effect against line-boundinterference emissions
Increase in the interference immunityof the connected equipment
APPLICATIONS APPLICATIONS
Filtre d’antiparasitage pour lasuppression des parasites côtésecteur des appareils individuels, desconvertisseurs de fréquence ou toustypes d’appareils.
Radio interference suppression filterfor line-side interference suppressionof single devices, frequency inverters oras group interference suppression.
DONNÉES TECHNIQUES TECHNICAL DATA
Courant de fuite 60.00 mA, Température ambiante max. 50 °C, Indice deprotection IP 00 Leakage current 60.00 mA, Ambient temperature max.122 °F / 50 °C, Degree of protection IP 00
Désignation duproduitN° de référence
Tensionnominale Vac
Plagede tension Vac
Courantnominal A
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
VoltageRange Vac
RatedCurrent A
DimensionsW/H/D in mm
HLD 103-500/270 3 x 520 3 x 0 - 520 3 x 270 260/100/380HLD 103-500/400 3 x 520 3 x 0 - 520 3 x 400 260/100/380HLD 103-500/750 3 x 520 3 x 0 - 520 3 x 750 260/110/390
Filtre d’antiparasitage, triphaséRadio interference suppression filter, three-phaseHLD 110
W J
AVANTAGES BENEFITS
Pour une suppression améliorée desinterférences électromagnétiques
Concept de filtre à un étage
Filtrage efficace des émissionsparasites liées aux câbles
Augmentation de l’immunité auxparasites des consommateursraccordés
For enhanced EMI suppression
Single-stage filter concept
Efficient filter effect against line-boundinterference emissions
Increase in the interference immunityof the connected equipment
APPLICATIONS APPLICATIONS
Filtre d’antiparasitage pour lasuppression des parasites côtésecteur des appareils individuels, desconvertisseurs de fréquence ou toustypes d’appareils.
Radio interference suppression filterfor line-side interference suppressionof single devices, frequency inverters oras group interference suppression.
DONNÉES TECHNIQUES TECHNICAL DATA
Courant de fuite 20.00 - 37.00 mA, Température ambiante max. 50 °C, Indicede protection IP 20 Leakage current 20.00 to 37.00 mA, Ambient temperaturemax. 122 °F / 50 °C, Degree of protection IP 20
Désignation duproduitN° de référence
Tensionnominale Vac
Plagede tension Vac
Courantnominal A
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
VoltageRange Vac
RatedCurrent A
DimensionsW/H/D in mm
HLD 110-500/8 3 x 520 3 x 0 - 520 3 x 8 45/75/190HLD 110-500/12 3 x 520 3 x 0 - 520 3 x 12 45/75/220HLD 110-500/16 3 x 520 3 x 0 - 520 3 x 16 45/75/250HLD 110-500/30 3 x 520 3 x 0 - 520 3 x 30 55/95/270HLD 110-500/42 3 x 520 3 x 0 - 520 3 x 42 55/95/310HLD 110-500/55 3 x 520 3 x 0 - 520 3 x 55 85/95/250HLD 110-500/75 3 x 520 3 x 0 - 520 3 x 75 85/135/270HLD 110-500/100 3 x 520 3 x 0 - 520 3 x 100 95/150/270HLD 110-500/130 3 x 520 3 x 0 - 520 3 x 130 95/150/270HLD 110-500/180 3 x 520 3 x 0 - 520 3 x 180 130/181/380HLD 110-500/250 3 x 520 3 x 0 - 520 3 x 250 155/220/450
Inductances/Filtres CEMReactors/EMI filters3
Pour connaître les autres gammes avec courants de fuite réduits, veuillez consulter le site block.eu. For further series with reduced leakage currents please check block.eu.
100Sujet à modificationSubject to change
Filtre d’antiparasitage, triphasé, avec conducteurneutreRadio interference suppression filter,three-phase with neutral conductorHLV 110
W J
AVANTAGES BENEFITS
Pour une suppression améliorée desinterférences électromagnétiques
Concept de filtre à un étage
Filtrage efficace des émissionsparasites liées aux câbles
Augmentation de l’immunité auxparasites des consommateursraccordés
For enhanced EMI suppression
Single-stage filter concept
Efficient filter effect against line-boundinterference emissions
Increase in the interference immunityof the connected equipment
APPLICATIONS APPLICATIONS
Filtre d’antiparasitage pour lasuppression des parasites côtésecteur des appareils individuels, desconvertisseurs de fréquence ou toustypes d’appareils.
Radio interference suppression filterfor line-side interference suppressionof single devices, frequency inverters oras group interference suppression.
DONNÉES TECHNIQUES TECHNICAL DATA
Courant de fuite 19.00 - 37.00 mA, Température ambiante max. 50 °C, Indice deprotection IP 20 Leakage current 19.00 - 37.00 mA, Ambient temperature max.122 °F / 50 °C, Degree of protection IP 20
Désignation duproduitN° de référence
Tensionnominale Vac
Plagede tension Vac
Courantnominal A
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
VoltageRange Vac
RatedCurrent A
DimensionsW/H/D in mm
HLV 110-500/8 3 x 520 0 - 520 3 x 8+N 75/55/190HLV 110-500/12 3 x 520 0 - 520 3 x 12+N 75/55/220HLV 110-500/16 3 x 520 0 - 520 3 x 16+N 75/55/220HLV 110-500/30 3 x 520 0 - 520 3 x 30+N 95/70/270HLV 110-500/42 3 x 520 0 - 520 3 x 42+N 95/70/270HLV 110-500/55 3 x 520 0 - 520 3 x 55+N 95/100/250HLV 110-500/75 3 x 520 0 - 520 3 x 75+N 150/100/270HLV 110-500/100 3 x 520 0 - 520 3 x 100+N 150/115/320HLV 110-500/130 3 x 520 0 - 520 3 x 130+N 150/115/320HLV 110-500/180 3 x 520 0 - 520 3 x 180+N 180/150/380HLV 110-500/250 3 x 520 0 - 520 3 x 250+N 220/155/450
Circuit stabilisateur de tension magnétiqueMagnetic voltage stabilizerKH 250
J
AVANTAGES BENEFITS
Compensation des fluctuations duréseau
Atténuation des pics de tensionparasite asymétriques
Tenue aux coupures du réseau
Séparation galvanique du réseau
Anti-court-circuit
Anti-fonctionnement à vide
Sans parasite
Sans maintenance
Compensation for mains voltagefluctuations
Attenuation of asymmetric interferencevoltage peaks
Bridging voltage dips
Galvanic isolation from the mains
Short-circuit proof
No-load proof
RF interference-free
Service-free
APPLICATIONS APPLICATIONS
Circuit stabilisateur magnétiquepour la sécurisation de la tensiond’alimentation lors des surtensions duréseau, des sous-tension du réseau,des creux de tension, ainsi que deschocs de tension et des brèvescoupures de courant
Magnetic voltage stabilizer securingthe supply voltage in the event ofmains overvoltage, mains undervoltage,voltage dips and voltage surges and inthe case of brief voltage interruptions.
DONNÉES TECHNIQUES TECHNICAL DATA
Température ambiante +40 °C, Indice de protection IP 40 Ambient temperature104 °F / +40 °C, Degree of protection IP 40
Désignation duproduitN° de référence
Tensiond'entrée Vac
Tensionde sortie
Puissance VA DimensionsL/H/P en mm
Product NameOrder No.
InputVoltage Vac
OutputVoltage
Power VA DimensionsW/H/D in mm
KH 250 230 230 250 145/200/245
Inductances/Filtres CEMReactors/EMI filters 3
101Sujet à modification
Subject to change
Inductances/Filtres CEMReactors/EMI filters3
Aperçu inductances moteur/filtres sinus Overview motor reactors/sine filters
TypeDésignationSort Pl
age
de te
nsio
n Vo
ltage
ran
ge
Courant nominal (A)Rated current (A)
MR3 Inductance moteur 0 - 500Inductance moteur 0 - 500 Vac 2,5 4 6 8 10 13 18 24 30 37 422,5 4 6 8 10 13 18 24 30 37 422,5 4 6 8 10 13 18 24 30 37 422,5 4 6 8 10 13 18 24 30 37 422,5 4 6 8 10 13 18 24 30 37 422,5 4 6 8 10 13 18 24 30 37 422,5 4 6 8 10 13 18 24 30 37 422,5 4 6 8 10 13 18 24 30 37 422,5 4 6 8 10 13 18 24 30 37 422,5 4 6 8 10 13 18 24 30 37 422,5 4 6 8 10 13 18 24 30 37 42
SFB Filtre sinusoïdal 0 - 520 Vac 4 10 16,5 23,5 32 3710 16,5 23,5 32 3710 16,5 23,5 32 3710 16,5 23,5 32 3710 16,5 23,5 32 3710 16,5 23,5 32 3710 16,5 23,5 32 37
SFA 400 Filtre sinusoïdal tous pôles 0 - 480Filtre sinusoïdal tous pôles 0 - 480 Vac 1,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 401,3 2,5 4 6 10 16,5 24 32 40
SFA 500 Filtre sinusoïdal tous pôles 0 - 500Filtre sinusoïdal tous pôles 0 - 500 Vac 6 13 2413 2413 2413 2413 24
TypeCourant nominal (A)Rated current (A)
MR3 48 61MR3 48 61MR3 48 61MR3 48 61
SFB 48 61 72 90 115 150 180 250 440 480SFB 48 61 72 90 115 150 180 250 440 480SFB 48 61 72 90 115 150 180 250 440 480SFB 48 61 72 90 115 150 180 250 440 480SFB 48 61 72 90 115 150 180 250 440 480SFB 48 61 72 90 115 150 180 250 440 480SFB 48 61 72 90 115 150 180 250 440 480SFB 48 61 72 90 115 150 180 250 440 480SFB 48 61 72 90 115 150 180 250 440 480SFB 48 61 72 90 115 150 180 250 440 480SFB 48 61 72 90 115 150 180 250 440 480SFB 48 61 72 90 115 150 180 250 440 480
SFA 400 50 60SFA 400 50 60SFA 400 50 60SFA 400 50 60SFA 400 50 60
SFA 500 46 65SFA 500 46 65SFA 500 46 65SFA 500 46 65
Outre notre service de livraison sous 24 h, découvrez notre gamme de produits standard. Pour plus d’informations, n’hésitez pas à consulter notre site block.eu.
In addition to our 24 hours BLOCK direct sales program an overview of the entire standard range. For more information see block.eu.
102Sujet à modificationSubject to change
Inductance moteurMotor reactorMR3 400
W J ß
AVANTAGES BENEFITS
Forte atténuation de la pente
Fort amortissement du signal FU
Réduction du courant de fuite dans unfaible volume
Augmentation de la longueur descâbles blindés possible
Haute efficacité
Très bonne protection contre lacorrosion et faible développement dubruit grâce à l’imprégnation sous vide
High damping of edge steepness
High damping of inverter switchingfrequency
Reduction of leakage current at lowconstruction volumes
Long shielded cable lengths possible
High efficiency
Very good corrosion protection and lownoise due to vacuum impregnation
APPLICATIONS APPLICATIONS
Inductance moteur pour limiter lespics de tension pouvant endommagerl’isolation du moteur (dv/dt).
Motor reactor for the limitation of thevoltage peaks damaging to the motorinsulation (dv/dt).
DONNÉES TECHNIQUES TECHNICAL DATA
Pour une puissance nominale motorisée de 0.75 - 30 kW, Pour des fréquencesd’impulsions de 3 à 8 kHz, Fréquence assignée de 0 à 50 Hz, Inductance 2,55 -0,10 mH, Classe d’isolation B, Indice de protection IP 00 For motor rated output0.75 - 30 kW, For switching frequencies of 3 to 8 kHz, Rated frequency from 0 to50 Hz, Inductance 2.55 - 0.10 mH, Insulation class B, Degree of protection IP 00
Désignation duproduitN° de référence
Tensionnominale Vac
Plagede tension Vac
Courantnominal A
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
VoltageRange Vac
RatedCurrent A
DimensionsW/H/D in mm
MR3 400/2,5 3 x 400 3 x 0 - 500 2,5 78/100/63MR3 400/4 3 x 400 3 x 0 - 500 4 78/100/63MR3 400/6 3 x 400 3 x 0 - 500 6 96/117/60MR3 400/8 3 x 400 3 x 0 - 500 8 96/117/60MR3 400/10 3 x 400 3 x 0 - 500 10 120/140/85MR3 400/13 3 x 400 3 x 0 - 500 13 120/140/85MR3 400/18 3 x 400 3 x 0 - 500 18 120/140/140MR3 400/24 3 x 400 3 x 0 - 500 24 120/140/95MR3 400/30 3 x 400 3 x 0 - 500 30 155/162/95MR3 400/37 3 x 400 3 x 0 - 500 37 155/162/95MR3 400/42 3 x 400 3 x 0 - 500 42 155/177/110MR3 400/48 3 x 400 3 x 0 - 500 48 185/210/102MR3 400/61 3 x 400 3 x 0 - 500 61 185/210/112
Filtre sinusoïdalSine filterSFB
W J ß
AVANTAGES BENEFITS
Élimination des surtensions au niveaudu moteur
Augmentation de la longueur de câblepossible
Réduction des bruits moteur
Réduction des émissions parasitesliées aux câbles et aux champs
Réduction des pertes moteur
Prevention of overvoltages on themotor
Long cable lengths possible
Reduction in motor noise
Reduction in line-borne and field-borneemitted interference
Reduction in motor losses
APPLICATIONS APPLICATIONS
Filtre sinusoïdal permettant d’éliminerles parasites en push-pull (modedifférentiel)
Sine filter for the suppression ofdifferential mode interference.
DONNÉES TECHNIQUES TECHNICAL DATA
Pour une puissance nominale motorisée de 1.5 - 260 kW, Pour des fréquencesd’impulsions de 4 à 8 kHz, Fréquence assignée de 0 à 150 Hz, Classe d’isolation H,Température ambiante max. 40 °C, Indice de protection IP 00 For motor ratedoutput 2 to 348 HP, For switching frequencies of 4 to 8 kHz, Rated frequencyfrom 0 to 150 Hz, Insulation class H, Maximum ambient temperature 104 °F /40 °C, Degree of protection IP 00
Désignation duproduitN° de référence
Tensionnominale Vac
Plagede tension Vac
Courantnominal A
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
VoltageRange Vac
RatedCurrent A
DimensionsW/H/D in mm
SFB 400/4 3 x 400 0 - 520 4 105/160/155SFB 400/10 3 x 400 0 - 520 10 120/160/155SFB 400/16,5 3 x 400 0 - 520 16,5 160/195/190SFB 400/23,5 3 x 400 0 - 520 23,5 190/280/240SFB 400/32 3 x 400 0 - 520 32 200/280/240SFB 400/37 3 x 400 0 - 520 37 210/280/240SFB 400/48 3 x 400 0 - 520 48 220/280/240SFB-N 400/61 3 x 400 0 - 520 61 228/228/300SFB-N 400/72 3 x 400 0 - 520 72 240/315/300SFB-N 400/90 3 x 400 0 - 520 90 240/320/300SFB 400/115 3 x 400 0 - 520 115 210/415/360SFB 400/150 3 x 400 0 - 520 150 225/415/360SFB 400/180 3 x 400 0 - 520 180 365/445/360SFB 400/250 3 x 400 0 - 520 250 500/450/400SFB 400/440 3 x 400 0 - 520 440 540/450/610SFB 400/480 3 x 400 0 - 520 480 400/430/750
Inductances/Filtres CEMReactors/EMI filters 3
Également disponible avec connexion blindée. Also available with shield connection.
103Sujet à modification
Subject to change
Filtre sinusoïdal tous pôlesAll-pole sine filterSF4
AVANTAGES BENEFITS
Amélioration du niveau d’efficacitéglobal du système d’entraînement
Utilisation possible de câbles moteurnon blindés
Amélioration des émissions parasitescâblées et rayonnées (150 kHz -300 MHz)
Réduction considérable des courantsde fuite secteur
Élimination des courants de palier
Prolongement de la durée de vie dumoteur
Optimized drive efficiency
Unshielded motor wires can be used
Improves conducted and radiatedelectromagnetic interference (150 kHz- 300 MHz)
Major reduction of leakage currents
Elimination of bearing currents
Increase of motor lifetime
APPLICATIONS APPLICATIONS
Filtre sinusoïdal permettant d’éliminerles parasites en push-pull (modedifférentiel) et les composants en modecommun. Conçu pour convertisseuravec connecteur DC-Link (+Vg/+Ug) ;fonctionne avec PWM continu.
Sine filter for the suppression ofdifferential mode interference andcommon mode interference. Designedfor inverter with DC link connector(+Vg/+Ug) and works with continuousPWM.
DONNÉES TECHNIQUES TECHNICAL DATA
Pour des fréquences d’impulsions de ð 4 kHz, Pour une puissance nominalemotorisée de 2.2 - 45 kW, Indice de protection IP 00 / IP 20, Fréquence assignéede 5 à 150 Hz, Classe d’isolation H For switching frequencies ð 4 kHz, For motorrated output 3 to 60.35 HP, Degree of protection IP 00 / IP 20, Rated frequencyfrom 5 to 150 Hz, Insulation class H
Désignation duproduitN° de référence
Tensionnominale Vac
Plagede tension Vac
Courantnominal A
DimensionsL/H/P en mm
Product NameOrder No.
RatedVoltage Vac
VoltageRange Vac
RatedCurrent A
DimensionsW/H/D in mm
SF4-CD006-500-0 3 x 500 0 - 500 6 (400 V ð 4 kHz) 5,2(500 V ð 4 kHz)
102/310/160
SF4-CD006-500-2 3 x 500 0 - 500 6 (400 V ð 4 kHz) 5,2(500 V ð 4 kHz)
105/310/200
SF4-CD013-500-0 3 x 500 0 - 500 13 (400 V ð 4 kHz)11,8 (500 V ð 4 kHz)
117/390/206
SF4-CD013-500-2 3 x 500 0 - 500 13 (400 V ð 4 kHz)11,8 (500 V ð 4 kHz)
120/390/215
SF4-CD024-500-0 3 x 500 0 - 500 24 (400 V ð 4 kHz)22,6 (500 V ð 4 kHz)
132/450/260
SF4-CD024-500-2 3 x 500 0 - 500 24 (400 V ð 4 kHz)22,6 (500 V ð 4 kHz)
135/450/270
SF4-CE046-500-0 3 x 500 0 - 500 46 (400 V ð 4 kHz)43,3 (500 V ð 4 kHz)
157/450/310
SF4-CE046-500-2 3 x 500 0 - 500 46 (400 V ð 4 kHz)43,3 (500 V ð 4 kHz)
160/450/310
SF4-CE065-500-0 3 x 500 0 - 500 65 (400 V ð 4 kHz) 59(500 V ð 4 kHz)
0/0/0
SF4-CE110-500-0 3 x 500 0 - 500 110 (400 V ð 4 kHz)105 (500 V ð 4 kHz)
280/506/280
Inductances/Filtres CEMReactors/EMI filters3
Sur demande
SF4-…-0 = Indice de protection Degree of protection IP 00SF4-…-2 = Indice de protection Degree of protection IP 20
104Sujet à modificationSubject to change
Inductances/Filtres CEMReactors/EMI filters 3
105Sujet à modification
Subject to change
Simulation thermique Thermal simulationr Plage de température Temperature range: -80 °C – +180 °Cr Humidité de l’air Humidity: 0 % – 100 %
À propos de nos services About our products and services
En tant qu’expert en développement produit, BLOCK propose à ses clients de nombreuses solutions d’assistance afin de prouver la fiabilité de ses produits dans des conditions de fonctionnement et environnementales extrêmes. Nous vous accompagnons à chaque étape du processus de développe-ment du produit, depuis des conseils techniques jusqu’à la réalisation de tests de fiabilité en interne, en passant par la sélection des tests appropriés.
BLOCK has many years of design engineering experience and works in partnership with its customers, providing a variety of sources of support for proving the reliability of products when subject to environmental and operational loads. We will be at your side at every stage of the product creation pro-cess, helping you to select suitable trials and even carrying out in-process reliability tests.
Temperature range: -80 °C – +180 °C0 % – 100 %0 % – 100 %0 % – 100 %0 % – 100 %
r Service CEM EMC servicer Test climatique Climatic testingr Test de résistance aux chocs et aux vibrations Shock and vibration testingr Mesure de décharge partielle Partial discharge measuringr Dispositifs d’affichage RoHS RoHS Screening
Tests de résistance aux chocs et aux vibrations Shock and vibration testsPoids de test maximal : 350 kgOscillations sinusoïdales, résistance aux chocs et bruit à large bande
Max. weight of DUT up to 350 kgSwept sine, shock and random r Pointe d’effort max.: Max. peak-force: 22,2 kNr Accélération max.: Max. acceleration: Sine 40 g (60 g in vertical)r Choc: Shock: 150 gr Aléatoire (RMS): Random (RMS): 30 gr Vitesse max.: Max. velocity: 2 m/s
106Sujet à modificationSubject to change
Avec cette station de test, les défis les plus divers posés par les circuits de refroidissement peuvent être relevés. Nos pro-duits peuvent ainsi être adaptés de manière optimale à leurs applications respectives.
With the present test station, the most diverse challenges from cooling circuits can be recreated. Our products can therefore be optimally adapted to respective applications. Analyse par rayons X 3D
3D X-ray analysis
Station de test BLOCK pour refroidissement par liquide BLOCK test station for liquid cooling
107Sujet à modification
Subject to change
All our products, such as transformers, reactors, mains units and radio interference suppression filters are deve-loped and produced with the customer and market in mind. You will find them wherever a reliable mains interface is needed. Our accredited EMC test laboratory functions as an independent business divi-sion. The laboratory concen-trates on EMC services in the field of industry standards for products in the capital goods industry.r Consultancy, contribution, suppressionr There right from the start of developmentr Accreditation in accordance with DIN EN ISO/IEC 17025.r EMC interference suppres- sion componentsr DIN EN ISO 9001 certifiedr Mobile EMC-equipment
EMC serviceTous les produits (par ex. transformateurs, bobines de réactance, alimentations et filtres antiparasites) sont développés et fabriqués en tenant compte des impératifs des clients et du marché. Vous les retrouverez partout où un réseau fiable est néces-saire. Notre laboratoire CEM fonctionne comme une division autonome et indépendante. Il se concentre sur les servi-ces CEM dans le domaine des normes de l’industrie, pour les produits des biens d’équipement.r Conseil, contribution, suppressionr Assistance tout au long du projetr Accréditation selon DIN EN ISO/IEC 17025.r Composants antiparasite CEM adaptésr Entreprise certifiée intégralement selon DIN EN ISO 9001r Équipement CEM mobile
Service CEM
108Sujet à modificationSubject to change
109Sujet à modification
Subject to change
Sujet à modificationSubject to change110
ESP 34
ESS 36
ETTK 26
EVKE 30
FL 57
FST 22
GLC 87
GNC 88
HF1P 230 96
HF1K 400 97
HFD 156 99
HFE 156 99
HLD 103 100
HLD 110 100
HLV 110 101
KH 250 101
JET 35
LR3-A 93
LR3 400 94
LR3A 400 95
MR3 400 103
NKE 230/400 93
PC-0424-017-0 83
PC-0424-115-0 84
PC-0524-400-0 82
PC 1AC 69
PC 2AC 70
PC 3AC 70
PC Combi UPS 81
PC-KOK1 85
PC-CON1 85
PC RE 81
PEL 67
PEL Neo 67
PELR 80
PLED 72
PM 1AC 68
PM 2AC 68
APERÇU DES TYPES DE PRODUITSOVERVIEW FOR ALL TYPES
ACT 29
AIM 33
AT3 35
AVB 54
BASIC FIX 80
BASIC SMART 79
BG 50
BGE 49
BGUK 50
BR 43
BRS 43
BUST 21
CLI 46
CLI-S 46
CT 21
CU-TIW 44
CU-V 44
CUL 45
DCT 87
DNC 88
DR3 96
E-JET 34
EasyB 1 voie 76
EasyB 2 voies 77
EB-BAR 78
EB-COV 78
EB-GND 77
EB-IO-LINK 78
EB-MARK 78
EB-MODBUS-RTU 78
EB-PMM 78
EB-PT2-0 78
ECONOMY SMART 79
ES 00 41
ES 30 41
ESG 3 42
ESG 4 42
ESG 5 42
ESG 6 41
ESG 7 42
PAGEPAGE
PRODUITPRODUCT
PT 56
PV-KOK2 85
PV-USB/SERIELL 85
PV-CON 85
PVAF 83
PVSB 400 71
PVSE 230 69
PVSE 400 71
PVSL 400 72
PVUA 82
PVUC 84
RD 47
RKD 39
RTE 40
SET-G 47
SET-S 48
SET-SIL 48
SF4 104
SFB 103
SIM 29
SMTT 28
ST 18
STE 15
STEU 16
STSU 20
STU 19
TIM 26
TOGA 49
TT1 25
TT3 27
TT3 Neo 27
TTMS 28
USTE 17
VB 53
VC 55
VCM 55
111Sujet à modification
Subject to change
APERÇU DES TYPES DE PRODUITSOVERVIEW FOR ALL TYPES
Sujet à modificationSubject to change112
INDEX ALPHABÉTIQUE
Adapteurs USB 85
Alimentation à découpage 67
Alimentation à découpage primaire 67
Alimentations CC 66
Alimentations de courant alternatif pour laboratoires 43
Alimentations/pilotes LED 72
Alimentation redressée et filtrée 86
Autotransformateurs de ballast 33
Alimentations secourues 81
Autotransformateurs 33
Autotransformateurs variables-toriques 36
Bobines de réactance à courant de commutation 93
Borne collective à contact sec 77
Câble adaptateur 85
CC-ASI 81
CC-ASI modules de control 84
Circuits stabilisateurs de tension magnétique 101
Coffrets 49
Coffrets en acier 49
Coffrets métalliques 49
Composants inductifs 60
Disjoncteurs 74
Disjoncteurs 1 voie 76
Disjoncteurs 2 voies 77
Disjoncteurs éléctroniques 74
Équipements de mesure 43
Équipements de test 43
Fils 44
Fils de cuivre émaillés 45
Fils de litz 46
Fils de litz cuivre 46
Fils de litz cuivre tressés 46
Fils résistifs 47
Filtres anti-harmoniques 96
Filtres CEM 98
Filtres d’antiparasitage 98
Filtres moteur 102
Filtres passifs 98
Filtres sinusoïdal 102
Filtres sinusoïdal tous pôles 104
A
B
M
S
Gaines 47
Gaines isolantes 47
Gaines en silicone 48
Gaines thermorétractables 48
Gaines en tissu 47
Inductances 90
Inductances CEM 92
Inductances de ligne 92
Inductance pour circuit de filtrage 96
Limitations de courant 76
Limiteurs de courant 41
Modules accumulateurs 83
Modules accumulateurs UPS CC 83
Modules condensateurs 83
Modules d’amplification du potentiel 78
Modules de batterie 83
Modules de communication 78
Modules de diagnostic pour voies uniques 79
Modules de protection 76
Modules de redondance 80
Modules de redondance à diodes 80
Modules tampon 84
Pilote LED à courant constant pour LED haute puissance 72
Pilotes de LED 72
Prise femelle 85
Protections sélectives 76
Stabilisateurs 101
Stabilisateurs de tension 101
Suppression des parasites 98
Transformateurs 12
Transformateurs de contrôle 14
Transformateurs de séparation des circuits 24
Transformateurs FAIL-SAFE 22
Transformateurs plat 52
Transformateurs pour circuits imprimé 52
Transformateurs toriques 38
Transformateurs variables 36
Unités d’alimentation 64
Unités de charge et de contrôle 81
Unités de contrôle d’accumulateurs 81
T
D
E
F
P
U
C
G
L
113Sujet à modification
Subject to change
1-Channel circuit breakers 76
2-Channel circuit breakers 77
AC current supplies for laboratories 43
Accumulator control units 81
Accumulator modules 83
Adapter cables 85
All-pole sine filters 104
Ballast auto transformers 33
Battery modules 83
Buffer modules 84
Capacitor modules 83
Circuit breakers 74
Communication cables 85
Communication modules 78
Commutating reactors 93
Constant current LED driver for High Power LED 72
Control transformers 14
Copper litz wires 46
Current limitations 76
DC power supplies 66
DC-UPS 81
DC-UPS Accumulator modules 83
DC-UPS Control modules 84
Decoupling modules for power supplies 80
Detuned reactors 96
Diagnosis modules for single channels 79
Diode redundancy modules 80
Drivers for LEDs 72
Electronic circuit breakers 74
EMI filters 98
EMC reactors 92
Enameled copper wires 45
Enclosures 49
Fabric sleevings 27
FAIL-SAFE transformers 22
Female plugs 85
Ground modules 77
Harmonic filters 96
Heat shrinkable sleevings 48
Inductive components 60
Inrush current limiters 41
Insulating sleevings 47
Interference suppressions 98
Isolating transformers 24
A
B
L
M
S
LED power supplies/drivers 72
Line reactors 92
Litz wires 46
Loading and controlling unit 81
Low profile transformers 52
Magnetic voltage stabilizers 101
Measurement equipment 43
Metal enclosures 49
Motor filters 102
Non-stabilized power supplies 86
Output expanders 78
Passive filters 98
PCB transformers 52
Power supply units 64
Primary switched mode power supplies 67
Print transformers 52
Protection modules 76
Radio interference suppression filters 98
Reactors 90
Redundancy modules 80
Resistance wires 47
Selective protections 76
Sine filters 102
Sleevings 47
Silicone sleevings 48
Stabilizers 101
Steel enclosures 49
Stranded copper litz wires 46
Switched mode power supplies 67
Tapped transformers 33
Test equipment 43
Toroidal transformers 38
Toroidal-variable-auto transformers 36
Transformers 12
Transformer power supplies 86
Uninterruptible power supplies 81
USB seriell adapter 85
Variable transformers 36
Voltage stabilizers 101
Wires 44
C
T
1
D
E
F
H
N
O
P
R
U
V
W
I
ALPHABETICAL INDEX
G
1. General1. These General Terms and Conditions of Sale and De-
livery of BLOCK Transformatoren-Elektronik GmbH, Max-Planck-Strasse 36-46, 27283 Verden (herein-after referred to as “Seller”), apply exclusively to companies within the meaning of Section 14 BGB [German Civil Code] i.e. natural persons or legal enti-ties, which, in respect of the purchase of goods, are acting in the performance of their commercial or in-dependent professional activities (hereinafter refer-red to as “Purchasers”).
2. These General Terms and Conditions of Sale and De-livery apply exclusively to all contracts concluded between the Seller and the Purchaser for the delive-ry of goods. Differing terms and conditions of purchase or other differing terms and conditions of the Purchaser shall not apply unless the Seller has expressly acknowledged them in writing. The Seller’s silence regarding such differing terms and condi-tions shall not be deemed in particular to be ack-nowledgment or consent, and this shall also apply to future contracts.
3. The General Terms and Conditions of Sale and Deli-very shall also apply to all future deliveries and servi-ces to the Purchaser until the Seller’s new General Terms and Conditions of Sale and Delivery apply.
2. Quotation, conclusion of contracts, scope of delivery1. The Seller’s quotations are subject to change and
are not binding. The Seller reserves the right to ma-ke insignificant deviations or deviations due to tech-nical progress in the design, execution and perfor-mance of the products compared with any catalogue, brochure or Internet information of the Seller. If the Purchaser places a delivery order/purchase order based on quotations subject to change, a contract shall be concluded, also in day-to-day business, only upon the written order confir-mation if the Purchaser requests such confirmation. In all other cases, the contract shall be concluded by delivery of the goods. If an order confirmation is pro-vided, this alone shall govern the content of the con-tract, in particular the scope of delivery and date of delivery.
2. If a purchase order received by the Seller is not con-firmed in writing within 2 weeks of its receipt, alt-hough confirmation was requested, or is not execut-ed, the Purchaser shall have the right to cancel the purchase order but without being able to assert any claims for damages against the Seller.
3. Prices and performance data and other declara-tions or assurances shall be binding for the Seller only if they have been made or confirmed by the Sel-ler in writing. Price lists, catalogue or internet price quotations or pricing in quotations are subject to change.
4. Any documents, drawings, details of weight, samp-les etc. enclosed with a quotation of the Seller or otherwise forwarded to the Purchaser are only de-termined approximately. In particular, these are neither a guarantee nor is hereby a procurement risk assumed unless this is expressly indicated in writing as “guaranteed by law” resp. “assumption of the procurement risk”. Any reference to standards and similar technical regulations as well shall not in-dicate a property of the Seller’s products unless this is expressly indicated as a “property of the pro-duct”. Paragraph 2.1, sentence 5, of these General Terms and Conditions of Sale and Delivery (relevan-ce of the order confirmation) remains unaffected by this.
5. The Seller shall only be obliged to deliver from its own stock (obligation to deliver from stock). As-sumption of a procurement risk or a procurement guarantee is also not based solely on our obligation to deliver an item which is defined solely by its class.
6. Partial deliveries are permitted if this can be reaso-nably expected of the Purchaser. Furthermore, the Seller shall have the right to deviate from the quan-tity agreed in the contract (excess or short delive-ries) to the extent customary in the trade and rea-sonable for the Purchaser but not more than 5 %.
7. Estimates of cost, drawings and other documents provided by the Seller shall remain the Seller’s pro-perty and copyright. They may not be made acces-sible to third parties without the Seller’s prior writ-ten consent.
3. Prices1. Prices are euro prices unless otherwise stated and
do not include value added tax. This shall be invoiced separately at the respectively valid rate in ac-cordance with respectively applicable tax provisions.
2. If no other agreements have been confirmed in wri-ting, prices are ex works or ex warehouse of the Sel-ler (EXW Incoterms 2010), unless otherwise stated Verden/Aller, Max-Planck-Str. 36-46, Germany, ex-cluding packaging and shipping charges, assembly, commissioning and other ancillary costs (e.g. cus-toms duty).
3. The minimum order value for articles is € 100.- re-sp. € 250.- for custom made products. Aluminium and copper surcharges are imposed separately in accordance with the DEL quotation of the order ent-ry date and shown accordingly in the quotation.
4. Terms of payment1. Unless otherwise agreed, all payments shall be ma-
de free Seller’s payment office at the latest within 30 calendar days of the invoice date without any de-duction. The right to deduct discount shall require a separate written agreement. Terms of payment shall be deemed met if the amount is at the Seller’s disposal within the term of payment. The Seller shall be free to choose the method of transmission for
the invoice. In particular, the Seller shall also have the right to transmit the invoice electronically e.g. by email.
2. The Purchaser shall have no right of retention if it is not based on the same contractual relationship. Set-off against disputed claims or claims which have not been recognised by declaratory judgment shall be excluded. The Seller shall have the right to avert the exercise of a right of retention by provision of security, also by guarantee.
3. If the Purchaser suspends its payments, there is an over-indebtedness or a petition for the institution of insolvency proceedings has been filed or the Pur-chaser is in default with the payment of due bills of exchange or cheques, the Seller’s total claim shall become due immediately.
4. The Seller shall have the right to request advance payment.
5. Retention of title1. The Seller shall retain title to the goods (hereinafter
referred to as “Goods Subject to Retention of Title”) until all claims against the Purchaser, to which the Seller is entitled, have been met. Pledging or assig-ning Goods Subject to Retention of Title as security shall not be admissible.
2. The Purchaser now already assigns to the Seller, by way of precaution, the future claims against its cus-tomers arising for it from the resale or rental, wit-hout the need for special declarations at a later date, in the event of the admissible resale or rental of the Goods Subject to Retention of Title in the or-dinary course of business, until all the Seller’s claims are paid back. The assignment shall also cover ba-lance claims resulting from existing current account relationships or from the termination of such relati-onships of the Purchaser with its customers. If the Goods Subject to Retention of Title are resold or rented together with other items, without a unit pri-ce being agreed for the Goods Subject to Retention of Title, the Purchaser shall assign to the Seller, with priority over the remaining claim, that portion of the total price claimed resp. the total rent which corres-ponds to the value of the Goods Subject to Retenti-on of Title invoiced by the Seller. The Purchaser shall be authorised to collect the assigned claims from the resale or rental until this is revoked. The Pur-chaser shall not, however, have the right to dispose of the assigned claims in another way e.g. by assign-ment. At the Seller’s request, the Purchaser shall notify the customer of the assignment and shall deli-ver the documents required e.g. invoices to assert the Seller’s rights against the customer to the Sel-ler and shall provide the required information. All costs of collection and any intervention shall be bor-ne by the Purchaser.
3. If the Purchaser processes the Goods Subject to Retention of Title, transforms them or combines them with other items, they shall be processed, transformed or combined for the Seller. The Seller shall become direct owner of the article produced by processing, transformation or combination. If this is not possible for legal reasons, the Seller and the Purchaser agree that the Seller shall become the owner of the new article at all times during proces-sing, transformation or combination. The Purchaser shall keep the new article for the Seller with the due diligence of prudent commercial judgment. Articles created from processing, transformation or combi-nation shall be deemed Goods Subject to Retention of Title. Where an item is processed, transformed or combined with other items that do not belong to the Seller, the Seller shall have co-ownership of the new article in the amount of the portion resulting from the ratio of the value of the processed, trans-formed or combined Goods Subject to Retention of Title to the new article. In the event of the sale or rental of the new article, the Purchaser herewith assigns to the Seller its claim arising from the sale or rental against its customer with all ancillary rights by way of precaution, without the need for subsequent special declarations. The assignment shall only apply, however, in the amount which corre-sponds to the value of the processed, transformed or combined Goods Subject to Retention of Title in-voiced by the Seller. The portion of the claim assig-ned to the Seller shall take precedence over the re-maining claim.
4. The Purchaser shall be obliged to treat the Goods Subject to Retention of Title with care at all times and to insure them at its own expense, in particular against fire and water damage and theft.
5. If the value of the security exceeds the Seller’s claims against the Purchaser arising from the ongo-ing business relationship in total by more than 20%, the Seller shall be obliged, at the Purchaser’s re-quest, to release securities, to which it is entitled, at its option.
6. Delivery, delivery period, default in delivery, force majeure1. Unless otherwise agreed in an individual case, deli-
veries shall be made on the basis of EXW Verden/Al-ler, Max-Planck-Str. 36-46, Germany (Incoterms 2010). If the Purchaser does not inform the Seller in good time prior to the agreed delivery date, at the latest 2 working days in advance, of the method of shipment, forwarding agent etc., the Seller shall ha-ve the right itself to commission a forwarding agent, carrier or third party otherwise designated to carry out the shipment at the Purchaser’s expense.
2. Specified delivery times are not binding unless otherwise agreed in writing. If delivery dates and pe-riods are not binding or approximate (ca., about etc.), the Seller shall use its best efforts to comply
with them. Delivery periods agreed as binding in wri-ting shall commence upon receipt of the order con-firmation by the Purchaser but not before all details about the execution of the order have been clarified and all other requirements to be fulfilled by the Pur-chaser (e.g. provision of necessary documents, au-thorisations and clearances) are met. The same shall apply to delivery dates. Deliveries shall be ad-missible before expiry of the delivery period.
3. The delivery period shall be deemed met when the goods are made available for collection by the for-warding agent, carrier or other third party designa-ted to carry out the shipment within the period (EXW Verden/Aller, Max-Planck-Str. 36-46, Germa-ny, in accordance with Incoterms 2010).
4. If the Seller does not receive deliveries or services from its sub-contractors for the Seller to provide deliveries or services which are due from the Seller under the contract, despite due and sufficient sto-cking in terms of quantity and quality under its deli-very or service agreement with the Purchaser, for reasons for which the Seller is not responsible, or they are incorrect or not in due time, or events of force majeure occur of significant duration (i.e. of longer than 14 calendar days), the Seller shall notify the Purchaser in writing or text form in due time. In such case, the Seller shall have the right to postpo-ne the delivery for the duration of the obstruction, or to rescind the contract in whole or in part for that part of the contract not yet fulfilled if the Seller has met its foregoing duty to provide information and has not assumed a procurement risk. Events of force majeure are strikes, lock-outs, official inter-vention, energy shortages and shortages of raw materials, transport bottlenecks through no fault of the Seller, company obstructions through no fault of the Seller, e.g. due to fire and water damage, and da-mage to machinery, and any other obstructions which, when considered objectively, were not caused by the Seller’s negligence.
5. If a delivery and/or service date or a delivery and/or service period is agreed with binding force and the agreed delivery or service date or the agreed delive-ry and/or service period is exceeded due to events according to paragraph 6.4 above, the Purchaser shall have the right, after a reasonable extension of time has elapsed without effect, to rescind the con-tract for that part not yet fulfilled. The Purchaser shall have no further claims, especially claims for da-mages, in such case if the Seller has met its forego-ing duty to provide information. The above provisi-ons pursuant to paragraph 6.5, sentence 1 and 2, shall apply accordingly if, for the reasons stated in paragraph 6.4, also without contractual agreement of a fixed delivery and/or service date, the Purchas-er cannot be objectively expected to adhere further to the contract.
6. If the Purchaser causes a delay in shipment or deli-very of the delivery items, the Seller shall have the right to charge the Purchaser for the additional costs incurred as a result.
7. Unless agreed by the parties in individual cases, the scope, type and any taking back of packaging of the goods to be delivered shall be at the Seller’s option, taking into account statutory provisions.
7. Passing of risk1. The risk of accidental loss or accidental deteriorati-
on of the goods shall pass to the Purchaser upon the delivery item being made available for collection by the forwarding agent, carrier or third parties otherwise designated to carry out the shipment (EXW Verden/Aller, Max-Planck-Str. 36-46, Germa-ny, pursuant to Incoterms 2010). This shall also ap-ply if partial deliveries are made or the Seller has ta-ken over other services (e.g. shipment or installation).
2. If shipment is delayed due to circumstances for which the Purchaser is responsible or the shipment is made at the Purchaser’s request at a later date than the agreed delivery date, the risk shall pass to the Purchaser from the date of notification of readi-ness for shipment for the duration of the delivery.
3. Deliveries shall not be insured against theft, breaka-ge, transport and fire damage without specific re-quest by the Purchaser. If the Purchaser requests the conclusion of an insurance policy, this shall be concluded at the Purchaser’s expense. The Purchas-er shall provide any cooperation required.
8. Claims for defects1. The Purchaser shall inspect the goods immediately
upon receipt if this is expedient in the ordinary course of business and, if a defect is found, shall no-tify the Seller immediately in writing. The inspection shall also include checking the function of the equip-ment and checking the correct display of measuring instruments. By negotiating any notices of defects, the Seller shall not waive the objection that the noti-ce was not in due time, unfounded in fact or otherwi-se insufficient.
2. If the Purchaser fails to provide this notice, the goods shall be deemed approved unless it is a defect which was not recognisable during the inspection. Section 377 et seq. HGB [German Commercial Code] shall furthermore apply.
3. Obvious damages sustained during transport or other defects identifiable already at the time of deli-very must also be confirmed by the deliverer’s sig-nature on the respective transport document when delivery is accepted. The Purchaser shall ensure that a corresponding confirmation is provided.
4. Supplementary performance shall be provided at the Seller’s option by remedying the defect or sup-plying an article free from defects. If supplementary
performance fails, the Purchaser shall have the right at its option to make a reduction or rescind the contract. This shall not affect the right to assert damages according to paragraph 9 of these General Terms and Conditions of Sale and Delivery.
5. Claims for defects shall become statute-barred within one year after the risk passes pursuant to paragraph 7 of these General Terms and Conditions of Sale and Delivery. This shall not apply in the cases pursuant to paragraph 9.2 of these General Terms and Conditions of Sale and Delivery. Furthermore, this shall not apply to goods which were used for a structure according to their customary manner of use and caused its defectiveness. In the above-men-tioned cases, statutory time limits shall apply.
9. Liability1. The Seller shall not be liable, in particular not for
claims by the Purchaser for damages or reimburse-ment of expenses, for whatever legal reason, and/or in the case of breach of duty from the obligation and tort.
2. The above exclusion of liability shall not apply- in the case of own intentional or grossly negligent
breach of duty and intentional or grossly negligent breach of duty by legal representatives or vicarious agents;
- in the case of violation of material contractual obli-gations; material contractual obligations are obliga-tions, the fulfilment of which defines the contract, and on which the Purchaser may rely;
- in the event of injury to life, limb and health, also by legal representatives or vicarious agents;
- in the case of default if delivery and/or service by a fixed date was agreed;
- where the Seller has assumed a guarantee for the quality of the goods or the existence of an outcome of performance or a procurement risk;
- in the case of liability under the Produkthaftungsge-setz [German Product Liability Act] or other manda-tory statutory liability.
3. If the Seller or its vicarious agents are responsible only for slight negligence and none of the cases spe-cified in bullet points 1., 3., 4., 5. and 6. of paragraph 9.2 above exist, the Seller’s liability shall be limited in amount to the damages foreseeable and typical for the contract at the time of concluding the contract, also in the case of violation of material contractual obligations.
4. Any further liability shall be excluded. 5. Exclusion resp. limitation of liability pursuant to pa-
ragraph 9.1 to 9.4 above and paragraph 9.6 shall apply to the same extent for the benefit of executive and non-executive employees and other vicarious agents as well as the Seller’s sub-contractors.
6. If the Purchaser is entitled to claims for damages in accordance with this paragraph 9, these shall be-come statute-barred upon expiry of the limitation period pursuant to paragraph 8.5 of these General Terms and Conditions of Sale and Delivery unless there are mandatory legal limitation periods to the contrary, such as in the case of supplier recourse pursuant to Section 445b BGB. Paragraph 9.2 of these General Terms and Conditions of Sale and De-livery shall apply mutatis mutandis.
7. There is no connection between the reversal of the burden of proof and the foregoing provisions.
10. Prohibition of assignment The Purchaser may assign claims against the Seller
only with the prior written consent of the Seller. This reservation of consent shall not apply to purchase price claims and other pecuniary claims.
11. Delivery of equipment for a trial period In the case of delivery of equipment for a trial period,
the Purchaser shall, unless otherwise agreed, pay the freight charges as well as the costs for pa-ckaging and insurance and for any reduction in value that may have occurred. The Purchaser shall also be liable for any loss of or damage to the delivered goods during the trial period. If goods are returned, they must always be in a perfectly cleaned condition and insured for transport at the expense of the Pur-chaser.
12. Final provisions1. Unless otherwise stated in the Seller‘s order confir-
mation, the place of performance for deliveries and payments shall always be the Seller‘s registered of-fice.
2. Amendments to and modifications of the contract between the Purchaser and the Seller shall only be valid when given in writing. This shall also apply to the cancellation of this written form agreement its-elf. The precedence of an individual agreement - also verbal - pursuant to 305b BGB remains unaffected by this.
3. Any disputes shall be settled exclusively before a competent court of law at the location of the Seller’s registered office. The Seller shall, however, have the right to bring an action against the Purchaser at its place of general jurisdiction.
4. The law of the Federal Republic of Germany shall ap-ply, to the exclusion of the UN Sales Convention (CISG).
Status: 11/2018
GENERAL TERMS AND CONDITIONS OF SALE AND DELIVERY
Sujet à modificationSubject to change114
SubsidiariesBelgiumBLOCK Belgium BVBAGijmelsesteenweg 278B3201 LangdorpPhone: +32 [email protected]
China博洛科电气(昆山)有限公司BLOCK Electronics(Kunshan) Co., Ltd.Building 4, No.665, Jiande Road, Zhangpu Town, Kuns-han City, Jiangsu Province 215321, P.R. ChinaPhone: +86 0512 5798 [email protected]
DenmarkBLOCK Danmark ApSMax-Planck-Str. 36 - 4627283 VerdenPhone: +49 4231 [email protected]
FranceBLOCK France SARL13 Avenue du Bataillon Carmagnole Liberté69120 Vaulx-en-VelinPhone: +33 4 72 75 19 [email protected]
United KingdomBLOCK U.K. LIMITED24 Bentalls CentreColchester RoadHeybridgeMaldon, Essex CM9 4GDPhone: +44 1621 850 [email protected]
USABLOCK USA, Inc.10632 W. Grand AvenueFranklin Park, Illinois 60131Phone: +1 847 260 [email protected]
Agencies in GermanyHamburgSchleswig-HolsteinMecklenburg-VorpommernBLOCK Transformatoren-Elektronik GmbHFrank ClaußenSchwalbenweg 923812 WahlstedtPhone: +49 4231 [email protected] Code17000–2173922000–25999
HannoverBraunschweigWolfsburgGöttingenHamelnBLOCK Transformatoren-Elektronik GmbHMax-Planck-Str. 36 - 4627283 VerdenPhone: +49 4231 [email protected] Code29000–3199937000–3719937400–38999
Ostwestfalen-LippeGroßraum KasselBLOCK Transformatoren-Elektronik GmbHMax-Planck-Str. 36 - 4627283 VerdenPhone: +49 4231 [email protected] Code32000–34479
Nordwest/BremenOsnabrückBLOCK Transformatoren-Elektronik GmbHThomas WillamowskiLüneburger Straße 1528205 BremenPhone: +49 4231 [email protected] Code21740–2179926000–2899948400–4853949000–49999
BerlinBrandenburgMagdeburgDresdenBLOCK Transformatoren-Elektronik GmbHMax-Planck-Str. 36 - 4627283 VerdenPhone: +49 4231 [email protected] Code01000–0399906730–0699910000–1699939000–39999
NRW NordBLOCK Transformatoren-Elektronik GmbHMax-Planck-Str. 36-4627283 VerdenPhone: +49 4231 [email protected] Code44000–4839948540–4879958000–59999
NRW SüdBLOCK Transformatoren-Elektronik GmbHMathias StrackeAuf dem Hang 1557482 WendenPhone: +49 4231 [email protected] Code40000–4299950000–5399957000–57699
Rheinland-PfalzSüd-HessenSaarlandBLOCK Transformatoren-Elektronik GmbHJörg TheobaldMaria-Himmelfahrts-Weg 766773 SchwalbachPhone: +49 6834 - 94 99 970 [email protected] Code54180–5689965000–6929969440–6959976710–76899
HessenUnterfrankenBLOCK Transformatoren-Elektronik GmbHMax-Planck-Str. 36 - 4627283 VerdenPhone: +49 4231 [email protected] Code34480–3649960000–6499969400–6943996000–9619996400–9648997000–9799998600–98679
SachsenSachsen-AnhaltThüringenOberfrankenBLOCK Transformatoren-Elektronik GmbHMatthias LeipoldObere Zense 2407616 BürgelPhone: +49 4231 [email protected] Code04000–0672907000–0999937200–3739995000–9599996200–9639996500–9652998000–9859998680–99999
Baden-Württemberg NordIngenieurbüroG. ZimmermannWunnensteinstr. 2171723 GroßbottwarPhone: +49 7148 [email protected] Code70000–7179973000–76709
Baden-Württemberg SüdBLOCK Transformatoren-Elektronik GmbHJochen HillerAdlerstraße 1272574 Bad UrachPhone: +49 42 31 [email protected] Code72000–7289977000–7999988000–8929989500–89999
NordbayernMittelfrankenBLOCK Transformatoren-Elektronik GmbHAlfred DehmelSchlösseläcker 1892318 NeumarktPhone: +49 9181 [email protected] Code90000–93999
BayernBLOCK Transformatoren-Elektronik GmbHAndreas RüfferParkstr. 1185435 ErdingPhone: +49 4231 [email protected] Code80000–8799989300–8949994000–94999
International agenciesAustriaRegatronicRegel- und Antriebselektronik GmbHGewerbepark 94201 GramastettenPhone: +43 7239 [email protected]
Hong Kong申佳有限公司 Sunnice Supplies Co., Ltd.Flat Q, 12/F., Everest Industrial Centre396 Kwun Tong RoadKowloonHong KongPhone: +852 2790 [email protected]
IcelandSpennubreytar ehfSuourhella 5221 HafnarfjördurPhone: +354 [email protected]
ItalySINTELSocietà Internazionale Elettronica s.r.l.Via Raffaello Sanzio, 2/D21013 Gallarate/VaresePhone: +39 0331 [email protected]
LithuaniaJSC SantavilteEuropos pr. 12146339 KaunasPhone: +370 37 [email protected]
NetherlandsELINCOM ELECTRONICS B.V.Klaverbaan 101-1032908 KD Capelle aan den IjsselPhone: +31 10 [email protected]
New ZealandMARDAG HOLDINGS LIMITED17 Wall Place TawaPO BOX 51184 TawaWellingtonPhone: +64 4 [email protected]
PortugalZeben Sistemas EletrónicosTravessa de Baixo, No. 54935-571 Castelo do NeivaViana do CasteloPhone: +351 253 818 [email protected]
RussiaMEG Electro, LLCUIitsa Scherbakovskaya 53 (Bld. 17)105187 MoscowPhone/Fax: +7 495 989 7780, + 7 495 647 0833Phone: +7 495 720 [email protected]
South KoreaHertz Technology Co, Ltd.Room No. 1404, Kolon Digital Tower Aston,505-14, Gasan-dong, Geum-cheon-gu, Seoul, KoreaPhone: +82 2 3281 0811 [email protected]
SpainEFIBAT SERVICIOS TÉCNICOS, SAc/ Leonardo da Vinci, 41. Polígono de Roces33211. Gijón. AsturiasPhone: +34 984 103 000www.efi bat.cominfo@efi bat.com
ELECTRONICA OLFER, S.L.P.A.E. NEISA AVANCE I.Avda de la Industria 6-8,Naves 20-21 28108Alcobendas - Madrid, EspañaTel: 0034 914 840 [email protected]
Sumelec Navarra SLPol. Ind. Talluntxe II - Calle F, 1231110 Noáin Navarra EspañaTel: 0034 948 368 [email protected]
SwitzerlandPG Transformatoren GmbHGlattalstrasse 5058153 RümlangPhone: +41 44 817 31 [email protected]
TaiwanKingdatron Electronic Industrial Co. LTD.7th Floor, No. 19, Lane 221, Gang Qian RoadTaipei Taiwan 11494Phone: +886 2 2659-6058 Ext. 19Fax: +886 2 [email protected]
ThailandPE AUTOMATION CO., LTD.89/104 Soi-Prayasuren 21 Yak 3, Bangchan, Klongsamwa Bangkok 10510Phone: +66 2 754 [email protected]
TurkeySANIL Teknik Elektrik San. ve Tic. Ltd. Şti.Okçumusa Caddesi, Tutsak SokakNo: 27/5 KaraköyIstanbul 34420Phone: +90 212 256 94 [email protected]
ManufacturingRepresentativesThe Americas
North & Central CaliforniaNorth NevadaDynamic Measurement & Control Solutions, LLCP.O. Box 840Watsonville, CA 95077Phone: +1 408 444-6394www.dynamicrep.com
ArkansasLouisianaMinnesotaNorth DakotaSouth DakotaOklahomaWestern WisconsinJ. Marolt Consultants, Inc.P.O. Box 2008Maple Grove, MN 55311Phone: +1 612 432-8422www.jmaroltconsultants.com
Michigan Russell Sales, Inc975 Spaulding Ave, SESuite DAda, MI 49301Phone: +1 616 956-9111www.russellsales.com
IndianaOhioKentuckySmith Automation1950 E. Greyhound PassSuite 18-337Carmel, IN 46033Phone: +1 317 773-8786www.smithautomation.com
North CarolinaSouth CarolinaWest VirginiaVirginiaMarylandTrapp Industrial1030 Industrial DriveMatthews, NC 28105Phone: +1 704 821-5187www.trappindustrial.com
Mexico (Entire country)OAS de MexicoAv. Ninos Heroes 2987-208Guadalajara, JaliscoMexico 44520Phone: +52 33 3122 0788www.odonnellsw.com
Distributors
Allied Electronics & Automationwww.alliedelec.com
Bürklin GmbH & Co. KGwww.buerklin.com
Conrad Electronic SEwww.conrad.com
Distrelec GmbHwww.distrelec.de
E.T.N. Groupewww.etn.fr
Newarkwww.newark.com
Premier Farnellwww.farnell.com
reichelt elektronik GmbH & Co. KGwww.reichelt.com
RS Componentswww.rs-online.com
BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36–46 • 27283 Verden • GermanyPhone +49 4231 678-0 • Fax +49 4231 [email protected] • block.eu
Eine vollständige Liste unserer Distributorenund Großhändler finden Sie unter: block.euYou can find a full list of our distributors at: block.eu
BD
20
18
-19
A8
/FR
-EN
G/0
8-1
8/R
EV0
RO
S/P
rint
ed in
Ger
man
y