Bulletin HY14-2000/US
DistributorValve Program
Effective: June 1, 2003Supersedes: DL101 dated 10/00
DVG18DVA20DVG20DVA35DVG35DVG80DVA / DVG AccessoriesIn-Line AccessoriesHand PumpsHydraulic Remote ControlsPneumatic Remote ControlsHydraulic Overspeed ControlVG35EH DCV
II Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA
Distributor Valve ProgramBulletin HY14-2000/US
catalog.p65, dd
� Copyright 2003, Parker Hannifin Corporation, All Rights Reserved
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONALINJURY AND PROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by usershaving technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Dueto the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection ofthe products and systems and assuring that all performance, safety and warning requirements of the application are met.The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation andits subsidiaries at any time without notice.
WARNING
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governedby the provisions stated in the "Offer of Sale".
Offer of Sale
Distributor Valve ProgramBulletin HY14-2000/US
III Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA
Notes
Distributor Valve ProgramBulletin HY14-2000/US
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA
Notes
14
Distributor Valve ProgramBulletin HY14-2000/US
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA
Notes
24
Distributor Valve ProgramBulletin HY14-2000/US
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA
Notes
31
Distributor Valve ProgramBulletin HY14-2000/US
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA
The items described in this document and other documents or descriptions provided by Parker Hannifin Corporation, its subsidiaries and its authorizeddistributors are hereby offered for sale at prices to be established by Parker Hannifin Corporation, its subsidiaries and its authorized distributors. Thisoffer and its acceptance by any customer ("Buyer") shall be governed by all of the following Terms and Conditions. Buyer’s order for any such items,when communicated to Parker Hannifin Corporation, its subsidiary or an authorized distributor ("Seller") verbally or in writing, shall constitute acceptanceof this offer.
paid by Buyer. Unless otherwise agreed, Seller shall have the right to alter,discard or otherwise dispose of any special tooling or other property in itssole discretion at any time.8. Buyer’s Property: Any designs, tools, patterns, materials, drawings,confidential information or equipment furnished by Buyer or any otheritems which become Buyer’s property, may be considered obsolete andmay be destroyed by Seller after two (2) consecutive years have elapsedwithout Buyer placing an order for the items which are manufactured usingsuch property, Seller shall not be responsible for any loss or damage tosuch property while it is in Seller’s possession or control.9. Taxes: Unless otherwise indicated on the face hereof, all prices andcharges are exclusive of excise, sales, use, property, occupational or liketaxes which may be imposed by any taxing authority upon the manufac-ture, sale or delivery of the items sold hereunder. If any such taxes mustbe paid by Seller or if Seller is liable for the collection of such tax, theamount thereof shall be in addition to the amounts for the items sold. Buyeragrees to pay all such taxes or to reimburse Seller therefore upon receiptof its invoice. If Buyer claims exemption from any sales, use or other taximposed by any taxing authority, Buyer shall save Seller harmless fromand against any such tax, together with any interest or penalties thereonwhich may be assessed if the items are held to be taxable.10. Indemnity For Infringement of Intellectual Property Rights: Sellershall have no liability for infringement of any patents, trademarks, copy-rights, trade dress, trade secrets or similar rights except as provided in thisPart 10. Seller will defend and indemnify Buyer against allegations ofinfringement of U.S. Patents, U.S. Trademarks, copyrights, trade dressand trade secrets (hereinafter ‘Intellectual Property Rights’). Seller willdefend at its expense and will pay the cost of any settlement or damagesawarded in an action brought against Buyer based on an allegation thatan item sold pursuant to this contract infringes the Intellectual PropertyRights of a third party. Seller’s obligation to defend and indemnify Buyeris contingent on Buyer notifying Seller within ten (10) days after Buyerbecomes aware of such allegations of infringement, and Seller having solecontrol over the defense of any allegations or actions including allnegotiations for settlement or compromise. If an item sold hereunder issubject to a claim that it infringes the Intellectual Property Rights of a thirdparty, Seller may, at its sole expense and option, procure for Buyer theright to continue using said item, replace or modify said item so as to makeit noninfringing, or offer to accept return of said item and return thepurchase price less a reasonable allowance for depreciation. Notwith-standing the foregoing, Seller shall have no liability for claims of infringe-ment based on information provided by Buyer, or directed to itemsdelivered hereunder for which the designs are specified in whole or partby Buyer, or infringements resulting from the modification, combination oruse in a system of any item sold hereunder. The foregoing provisions ofthis Part 10 shall constitute Seller’s sole and exclusive liability and Buyer’ssole and exclusive remedy for infringement of Intellectual Property Rights.If a claim is based on information provided by Buyer or if the design for anitem delivered hereunder is specified in whole or in part by Buyer, Buyershall defend and indemnify Seller for all costs, expenses or judgmentsresulting from any claim that such item infringes any patent, trademark,copyright, trade dress, trade secret or any similar right.11. Force Majeure: Seller does not assume the risk of and shall not beliable for delay or failure to perform any of Seller’s obligations by reasonof circumstances beyond the reasonable control of Seller (hereinafter‘Events of Force Majeure’). Events of Force Majeure shall include withoutlimitation, accidents, acts of God, strikes or labor disputes, acts, laws,rules or regulations of any government or government agency, fires,floods, delays or failures in delivery of carriers or suppliers, shortages ofmaterials and any other cause beyond Seller’s control.12. Entire Agreement/Governing Law: The terms and conditions setforth herein, together with any amendments, modifications and anydifferent terms or conditions expressly accepted by Seller in writing, shallconstitute the entire Agreement concerning the items sold, and there areno oral or other representations or agreements which pertain thereto. ThisAgreement shall be governed in all respects by the law of the State of Ohio.No actions arising out of the sale of the items sold hereunder or thisAgreement may be brought by either party more than two (2) years afterthe cause of action accrues.
9/91-P
1. Terms and Conditions of Sale: All descriptions, quotations, propos-als, offers, acknowledgments, acceptances and sales of Seller’s productsare subject to and shall be governed exclusively by the terms andconditions stated herein. Buyer’s acceptance of any offer to sell is limitedto these terms and conditions. Any terms or conditions in addition to, orinconsistent with those stated herein, proposed by Buyer in any accep-tance of an offer by Seller, are hereby objected to. No such additional,different or inconsistent terms and conditions shall become part of thecontract between Buyer and Seller unless expressly accepted in writingby Seller. Seller’s acceptance of any offer to purchase by Buyer isexpressly conditional upon Buyer’s assent to all the terms and conditionsstated herein, including any terms in addition to, or inconsistent with thosecontained in Buyer’s offer, Acceptance of Seller’s products shall in allevents constitute such assent.2. Payment: Payment shall be made by Buyer net 30 days from the dateof delivery of the items purchased hereunder. Amounts not timely paidshall bear interest at the maximum rate permitted by law for each monthor portion thereof that the Buyer is late in making payment. Any claims byBuyer for omissions or shortages in a shipment shall be waived unlessSeller receives notice thereof within 30 days after Buyer’s receipt of theshipment.3. Delivery: Unless otherwise provided on the face hereof, delivery shallbe made F.O.B. Seller’s plant. Regardless of the method of delivery,however, risk of loss shall pass to Buyer upon Seller’s delivery to a carrier.Any delivery dates shown are approximate only and Seller shall have noliability for any delays in delivery.4. Warranty: Seller warrants that the items sold hereunder shall be freefrom defects in material or workmanship for a period of 18 months fromdate of shipment from Parker Hannifin Corporation. THIS WARRANTYCOMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING TOITEMS PROVIDED HEREUNDER. SELLER MAKES NO OTHER WAR-RANTY, GUARANTEE, OR REPRESENTATION OF ANY KIND WHAT-SOEVER. ALL OTHER WARRANTIES, INCLUDING BUT NOT LIM-ITED TO, MERCHANTABILITY AND FITNESS FOR PURPOSE,WHETHER EXPRESS, IMPLIED, OR ARISING BY OPERATION OFLAW, TRADE USAGE, OR COURSE OF DEALING ARE HEREBYDISCLAIMED. NOTWITHSTANDING THE FOREGOING, THERE ARENO WARRANTIES WHATSOEVER ON ITEMS BUILT OR ACQUIREDWHOLLY OR PARTIALLY, TO BUYER’S DESIGNS OR SPECIFICA-TIONS.5. Limitation Of Remedy: SELLER’S LIABILITY ARISING FROM ORIN ANY WAY CONNECTED WITH THE ITEMS SOLD OR THIS CON-TRACT SHALL BE LIMITED EXCLUSIVELY TO REPAIR OR RE-PLACEMENT OF THE ITEMS SOLD OR REFUND OF THE PURCHASEPRICE PAID BY BUYER, AT SELLER’S SOLE OPTION. IN NO EVENTSHALL SELLER BE LIABLE FOR ANY INCIDENTAL, CONSEQUEN-TIAL OR SPECIAL DAMAGES OF ANY KIND OR NATURE WHATSO-EVER, INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISINGFROM OR IN ANY WAY CONNECTED WITH THIS AGREEMENT ORITEMS SOLD HEREUNDER, WHETHER ALLEGED TO ARISE FROMBREACH OF CONTRACT, EXPRESS OR IMPLIED WARRANTY, OR INTORT, INCLUDING WITHOUT LIMITATION, NEGLIGENCE, FAILURETO WARN OR STRICT LIABILITY.6. Changes, Reschedules and Cancellations: Buyer may request tomodify the designs or specifications for the items sold hereunder as wellas the quantities and delivery dates thereof, or may request to cancel allor part of this order, however, no such requested modification or cancel-lation shall become part of the contract between Buyer and Seller unlessaccepted by Seller in a written amendment to this Agreement. Accep-tance of any such requested modification or cancellation shall be atSeller’s discretion, and shall be upon such terms and conditions as Sellermay require.7. Special Tooling: A tooling charge may be imposed for any specialtooling, including without limitation, dies, fixtures, molds and patterns,acquired to manufacture items sold pursuant to this contract. Such specialtooling shall be and remain Seller’s property notwithstanding payment ofany charges by Buyer. In no event will Buyer acquire any interest inapparatus belonging to Seller which is utilized in the manufacture of theitems sold hereunder, even if such apparatus has been specially con-verted or adapted for such manufacture and notwithstanding any charges
Offer of Sale
41
Bulletin HY14-2000/US,1M, 6/03, PHD
Parker Hannifin CorporationHydraulic Valve Division520 Ternes AvenueElyria, Ohio, USA 44035Tel: (440) 366-5200Fax: (440) 366-5253www.parker.com/hydraulicvalve
VG35EH Open-Center Directional Control ValveBulletin HY14-2007-B1/USBuild Program
Refer to PL HY14-2000/USfor current pricing information
Bul HY14-2007-B1.indd, dd
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA
Open-Center Directional Control ValveBulletin HY14-2007-B1/US
II
VG35EH Build Program
Technical Information
General Description ..........................................................................................................................................1
Operation ..........................................................................................................................................................1
Features ...........................................................................................................................................................1
Specifications ...................................................................................................................................................2
Weights .............................................................................................................................................................2
Connections .....................................................................................................................................................2
Ordering Information
Inlet Covers ......................................................................................................................................................3
Main Relief covers ............................................................................................................................................3
Outlet Covers ....................................................................................................................................................3
Power Beyond Outlet Covers ............................................................................................................................3
Stud Assembly Kits...........................................................................................................................................4
Pilot Generating/Regulating Section ................................................................................................................4
Work Sections ..................................................................................................................................................4
Offer of Sale ..........................................................................................................................................................II
Safety Guide ..........................................................................................................................................................II
Contents
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
• This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.
• The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
• To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
WARNING – USER RESPONSIBILITY
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed “Offer of Sale” elsewhere in this document or available at www.parker.com/hydraulicvalve.
© Copyright 2012, Parker Hannifin Corporation, All Rights Reserved
OFFER OF SALE
For safety information, see Safety Guide SG HY14-1000 at www.parker.com/safety or call 1-800-CParker.
SAFETY GUIDE
Bul HY14-2007-B1.indd, dd
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA
Open-Center Directional Control ValveBulletin HY14-2007-B1/US
1
VG35EH Build ProgramTechnical Information
General Description
The VG35 has been a strong and reliable player in the 170-246 LPM (45-65 GPM) open-center, directional control valve market for many years. Now it has a new, electrohydraulic package designed for open-center systems and for those customers wanting to take ma-chine control to the next level.
The offering consists of the following:
• A global solenoid (pwm) that can be used for proportional or on/off control. The connector options are Amp Jr., Deutsch and Weather Pak.
• Work sections rated to 275 Bar (4000 PSI): 4-way, 3-position; and 3-way, 3-position.
• A pilot generating/regulating section that is referred to as a “utility section”. The purpose of this section is to generate and regulate pilot pressure in an open-center circuit. This section is positioned adjacent to the inlet.
• An outlet that can accept an external regulated signal. This is an option, when a pilot generating/regulating or “utility” section is not required.
Outlet
Work Section
Utility Section
Operation
Open-center valves that are operated by either hydrau-lic-remote or electrohydraulic require a way to generate and regulate the pilot pressure. For hydraulic-remote operation, the regulated pilot pressure is needed for the pilot controllers. For electrohydraulic operation, the regulated pilot pressure is required for the work section solenoids. Generation and regulation of the pilot signal can be accomplished externally with an in-line solution, however, this approach requires extra plumbing.
The VG35 has an integrated section that selectively generates and regulates the pilot pressure to be sent to the hydraulic-remote controllers, or the solenoids installed in the work section.
When an operator selects a spool, a signal is sent to a normally open solenoid in the “utility” section. Pressure will then build until it reaches the setting of relief valve. This is sufficient pressure to move the main spool, so that it can be connected to the load pressure. At that point, the inlet of the valve will see system pressure, and the pressure-reducing valve in the “utility section” will regulate the pilot pressure to the hydraulic-remote controllers or the work section solenoids.
For electrohydraulic operation, optimizing machine control is achieved by having a dedicated drain for the work section solenoids. Therefore, the VG35EH pack-age isolates the solenoid within the control valve, and the solenoid drain port is located in the “utility section”.
Solenoid
Bul HY14-2007-B1.indd, dd
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA
Open-Center Directional Control ValveBulletin HY14-2007-B1/US
2
VG35EH Build ProgramTechnical Information
SpecificationsPressures Pump Inlet Ports: 275 Bar (4000 PSI)
Service Ports: 45 Bar (5000 PSI)
Pilot: 35 Bar (508 PSI) (input or internal supply)
Tank Return Ports: 15 Bar (220 PSI)
Solenoid Drain: 2 Bar (29 PSI)
Flow Rates (maximum recommended)
246 LPM (65 GPM)
Leakage Performance
With mineral oil, 100 SUS@ 49°C (120° F) at 75.9 Bar (1100 PSI) differential
Workport w/Steel Plug of no accessory: 30cc/min max.
Workport w/RV or RV+AC: 35cc/min max.
Hydraulic Fluid Mineral Base oil
For other fluids consult factory
Viscosity, working range: 15-380mm²/s (15-380 cSt)
Hydraulic Oil Temperature
Recommended Operating Range without Solenoid Operation: -30° to 90°C (-22 to 194°F)
Recommended Operating Range with Solenoid Operation: -20° to 80°C (-4 to 176°F)
Filtration (ISO4406)
20/18/14 in Main Flow Paths
18/16/13 Pilot Supply
Voltage 12 or 24 VDC
Frequency 100 ±10 Hz
Pilot 35 Bar (508 PSI) 15-23 LPM (4-6 GPM)
Current Input (I) 1.5A for 12 VDC0.75A for 24 VDC
Current (mA) for Spool Shift
Start ShiftFull Shift
12V 24V
550 225150 575
Insulation Material
Class H
Duty Cycle 100%
R20 Ohm 5.3 (±5%) for 12 VDC21.2 (±5%) for 24 VDC
Fluid Cleanliness
17/14 per ISO 4406
Ambient Temperature
-30° to 80°C (-22 to 176°F)
Fluid Temperature
-20° to 80°C (-4 to 194°F)
Solenoid Specifications
Inlet with relief 7.2 kg (15.8 lbs)
Work section – manual spring return 8.4 kg (18.4 lbs)
Work section – hydraulic remote 10.4 kg (22.8 lbs)
Work section – solenoid operated 10.8 kg (23.8 lbs)
Work section – pilot generation 9.6 kg (21.1 lbs)
Add for port relief 0.3 kg (0.65 lbs)
Outlet 4.8 kg (10.6 lbs)
Weights
O-ring boss ports SAE-J1926-1 BSPP ports ISO 1179-1
Thread Size
Description SAE# O-ring boss BSPP
Inlet port, Top or Side
16 1-5/16"-12 UNF 1"-11
Inlet port, Top or Side
20 1-5/8"-12 UNF 1-1/4"-11
Outlet port, Top or Side
16 1-5/16"-12 UNF 1"-11
Outlet port, Top or Side
20 1-5/8"-12 UNF 1-1/4"-11
Work Ports 16 1-5/16"-12 UNF 1"-11
Work Ports 12 1-1/16"-12 UNF 3/4"-14
Connections
Bul HY14-2007-B1.indd, dd
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA
Open-Center Directional Control ValveBulletin HY14-2007-B1/US
3
VG35EH Build ProgramOrdering Information
VG35EH Outlet Covers
Product Code Part Number SAE-20 Side SAE-20 Top SAE-24 SideNo Machined
PortsExt Pilot &
Drain SAE-6VG35-ZT99000 348 9106 285 X XVG35-ZT99022 348 9106 287 X X XVG35-ZT100000 348 9106 304 XVG35-ZT100022 348 9106 305 X XVG35-ZT00000 348 9106 306 XNOTES: 1. External pilot and drain ports are required to bring an outside pilot supply into the valve stack. 2. The external pilot and drain ports are NOT required when using a pilot generation utility section.
VG35EH Inlet Covers
Poduct Code Part Number SAE-16 Top SAE-16 Side SAE-20 Top SAE-20 Side Blocked Pilots
DVG35-A990 348 9175 009 X XDVG35-A880 348 9175 008 X XVG35-A990-BP 348 9155 034 X X XNOTES: 1. VG35-A990-BP is required when a pilot generation utility section is NOT used. 2. This inlet has face machining that terminates the internal pilot and drain galleries.
VG35EH Main Relief Options
Product Code Part Number800-2000
PSI2000-2500
PSI2500-3500
PSINo R/V Option
DVA35-MRV-1 391 1873 003 XDVA35-MRV-2 391 1873 004 XDVG35-HMRV 391 1873 137 XDV-MRVP 391 1873 005 X
VG35EH Pilot Generating Utility Sections
Product Code Part Number 12V 24V Deutsch
VG35EH-PGP2DA 348 9159 001 X XSOL-12V-DUMP DSL103AD012LWD6R X XSOL-24V-CONVT S10LWD6RD024 X X
NOTES: 1. SOL-12V-DUMP can be added to the Utility section. This allows for selective operation of VG35 work sections. 2. SOL-24V-CONVT coil will convert the Utility section from 12 volt to 24 volt. 3. Solenoids have 6" leadwires terminated with Deutsch DT04-2P receptacle with pin terminals.
Bul HY14-2007-B1.indd, dd
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA
Open-Center Directional Control ValveBulletin HY14-2007-B1/US
4
VG35EH Build ProgramOrdering Information
VG35EH Stud Assembly Kits
Product Code Part NumberNo of
SectionsDVG35-TSK-1 391 1873 138 1DVG35-TSK-2 391 1873 139 2DVG35-TSK-3 391 1873 140 3DVG35-TSK-4 391 1873 141 4DVG35-TSK-5 391 1873 142 5DVG35-TSK-6 391 1873 143 6DVG35-TSK-7 391 1873 144 7DVG35-TSK-8 391 1873 145 8NOTE: Remember to count pilot generating section as one section when ordering studs.
VG35EH Work Sections
Product Code Part Number
12 Volt 4-Way 3-Pos
Hold in Neutral
12 Volt 4-Way 3-Pos
Float in Neutral
12 Volt 3-Way 3-Pos
Hold in Neutral
24 Volt 4-Way 3-Pos
Hold in Neutral
24 Volt 4-Way 3-Pos
Float in Neutral
24 Volt 3-Way 3-Pos
Hold in Neutral
Solenoid Push Pin Override
VG35-HP2AS899 348 9152 161 XVG35-LP2AS899 348 9152 162 XVG35-JP2AS809 348 9151 020 XVG35-HP4AS899 348 9152 164 XVG35-LP4AS899 348 9152 165 XVG35-JP4AS809 348 9151 021 XVG35-HP2AOS899 348 9152 033 X XVG35-LP2AOS899 348 9152 062 X XVG35-JP2AOS809 348 9151 012 X XVG35-HP4AOS899 348 9152 127 X XVG35-LP4AOS899 348 9152 128 X XVG35-JP4AOS809 348 9151 022 X XSolenoid connector 391 1823 417 Pre-crimped AMP Jr. then 6" leadwires then Packard.
NOTES: 1. Port Accessories are same as DVA/DVG from Distributor Valve Program Bulletin HY14-2000/US. 2. Work sections listed have SAE-16 workports. 3. Work sections listed use "AMP Junior Power Timer" connectors. 4. Use adapter kit 391 1823 417 to convert from AMP Jr. to Packard, or AMP Jr. to leadwires. 5. Series circuit work sections are not available at this time.
VG35EH Power Beyond Outlet Covers
Product Code Part Number SAE-20 Top SAE-20 Side Non Ported
DVG35-TPB99 348 9176 008 X XDVG35-TPB00 348 9176 011 XNOTES: 1. Power Beyond Outlets have application limitations. 2. An outside pilot supply cannot be fed into them. 3. Additionally, a last in-line work section is required. 4. Consult factory for these special part numbers.
Covering the Industrial and Mobile markets, each catalog is paired with an interactive DVD. Call for your comprehensive guides today. 1-800-C-Parker.
Mobile Hydraulics Bulletin HY19-1012/US
Industrial Hydraulics Bulletin HY01-1001/US
Motors
PumpsPower Units Valves and Controls
Electronics/Remote Controls
Filtration
Compact Hydraulics Cylinders
Full line of high and low speed motors provides power up to 15,000 in-lbs of torque.
Broad line of energy- efficient hydraulic pumps that includes piston, vane and gear pumps.
The most complete line of standard, pre-engineered, cataloged hydraulic power units in the industry.
Hydraulic valves for virtually every hydraulic equipment application, from simple to precise control.
Parker’s unique IQAN approach combines sturdy, well-tested hardware with intelligent, flexible computing power.
Pressure and return line filters enhances machine life, reduces maintenance and lowers costs.
Self-contained with a mo-tor, gear pump, reservoir, internal valving, load hold checks and relief valves.
Standard and custom hydraulic cylinders for industrial and mobile applications.
Industry leader in the design and manufacture of hydraulic rack and pin-ion, and vane style rotary actuators.
Piston, bladder and dia-phragm type accumulators, gas bottles and KleenVent reservoir isolators.
Parker Chelsea leads the industry for engineering, innovation and performance in auxiliary power systems.
Solutions for complex cir-cuits that include threaded cartridge valves integrated into a single manifold.
www.parker.com/accumulator www.parker.com/oildyne www.parker.com/hydcyl www.parker.com/iqan
www.parker.com/hydraulicfilter www.parker.com/hcs www.parker.com/pumpmotor www.parker.com/chelsea
www.parker.com/pumpmotor www.parker.com/mobpump www.parker.com/actuator www.parker.com/hydraulicvalve
Rotary Actuator
Accumulators
Power Take Off
Extensive Hydraulic Product Offering
Integrated Hydraulic Circuits
Your Local Authorized Parker Distributor
Bulletin HY14-2007-B1/US, 3/12
Parker Hannifin CorporationHydraulic Valve Division520 Ternes AvenueElyria, Ohio 44035 USATel: 440-366-5100Fax: 440-366-5253www.parker.com/hydraulicvalve
© 2012 Parker Hannifin Corporation
Parker Hydraulics International Sales Offices
North AmericaHydraulics Group Headquarters6035 Parkland Boulevard Cleveland, OH 44124-4141 USA Tel: 216-896-3000 Fax: 216-896-4031
Parker Canada Division160 Chisholm Drive Milton, Ontario, L9T 3G9 Canada Tel: 905-693-3000 Fax: 905-876-1958
Mexico Parker Hannifin de MéxicoIndustrial Hydraulic Sales Eje Uno Norte No. 100 Parque Industrial Toluca 2000 Toluca, Edo. de Mexico CP 50100 Tel: 52 72 2275 4200 Fax: 52 72 2279 9308
EuropeHydraulics Group Headquarters La Tuilière 6CH-1163 Etoy, SwitzerlandTel: 41 21 821 8500Fax: 41 21 821 8580
Latin AmericaParker Hannifin Ind. e Com. Ltda Hydraulics DivisionAv. Frederico Ritter, 110094930-000 Cachoeirinha RS, Brazil Tel: 55 51 3470 9144 Fax: 55 51 3470 9215
Parker Hannifin Argentina S.A.I.C.Stephenson 27111667-Tortuguitas-Malvinas ArgentinasPcia. de Buenos Aires, Argentina Tel: 54 3327 44 4129 Fax: 54 3327 44 4199
Pan American Division7400 NW 19th Street, Suite A Miami, FL 33126 USA Tel: 305-470-8800 Fax: 305-470-8808
Industrial SalesCentral Region1042 Maple AvenueUnit 331Lisle, IL 60532 USATel: 630-964-0796
Great Lakes Region6035 Parkland Boulevard Cleveland, OH 44124-4141 USA Tel: 216-896-3000Fax: 216-896-4031
Gulf Region20002 Standing Cypress DriveSpring, TX 77379 USATel: 817-473-4431Fax: 888-227-9454
Southwest Region700 S. 4th AvenueMansfield, TX 76063 USATel: 817-473-4431Fax: 888-227-9454
Mid Atlantic & Southeast Regions1225 Old Alpharetta Rd Suite 290Alpharetta, GA 30005 USATel: 770-619-9767Fax: 770-619-9806
Midwest Region8145 Lewis RoadMinneapolis, MN 55427 USATel: 763-513-3535Fax: 763-544-3418
Northeast RegionP.O. Box 396Pine Brook, NJ 07058 USATel: 973-227-2565Fax: 973-227-2467
Northwest Region6458 North Basin Avenue Portland, OR 97217 USATel: 503-283-1020Fax: 866-611-7308
Pacific and Plains Region8460 Kass DriveBuena Park, CA 90621 USATel: 714-228-2509Fax: 714-228-2511
Mobile SalesMobile Sales Organization and Global Sales850 Arthur AvenueElk Grove Village, IL 60007 USATel: 847-258-6200Fax: 847-258-6299
Asia PacificParker Hannifin Shanghai Ltd.280 Yunqiao Road, Jin Qiao Export Processing Zone Shanghai 201206, China Tel: 86 21 2899 5000 Fax: 86 21 5834 8975
Parker Hannifin Hong Kong Ltd.Suites 01-04, 20/F,Tower 2, The Gateway, Harbour City, Tsimshatsui, Hong Kong Tel: 852 2428 8008 Fax: 852 2480 4256
Parker Hannifin Korea Ltd.18F KAMCO Yangjae Tower 949-3 Dogok1-dong, Gangnam-gu Seoul, 135-860, Korea Tel: 82 2 559 0408 Fax: 82 2 556 8187
Parker Hannifin India Pvt Ltd.Plot No. EL-26, MIDC, TTC Industrial Area Mahape, Navi Mumbai, 400 709, India Tel: 91 22 6513 7081 Fax: 91 22 2768 6841
Parker Hannifin AustraliaParker Hannifin Pty Ltd.9 Carrington Road Castle Hill, NSW 2154, Australia Tel: 612 9634 7777 Fax: 612 9842 5111
South AfricaParker Hannifin Africa Pty Ltd10 Berne AvenueAeroport Kempton Park 1620, Republic of South Africa Tel: 19 610 700 Fax: 13 927 213