20
ABSTRACT 1 DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC CONTROLS ON CONTAMINANT PATHWAYS NEAR THE ROYAL RIVER, MCKIN SUPERFUND SITE AREA, GRAY, MAINE By F.P. Lyford, L.E. Flight, Janet Radway Stone, and Scott Clifford ABSTRACT Vapor-diffusion samplers were used in the autumn of 1997 to determine the lateral extent and distribution of concentrations of a trichloroeth- ylene (TCE) plume in the ground-water discharge area near the McKin Superfund Site, Gray, Maine. Analyses of vapor in the samplers identified a plume about 800 feet wide entering the river near Boiling Springs, an area of ground-water discharge on the flood plain of the Royal River. The highest observed concentration of TCE in vapor was in an area of sand boils on the western bank of the river and about 200 feet downstream from Boiling Springs. Previous studies showed that most of the TCE load in the river originated in the area of the sand boils. In general, highest concentrations were observed on the western side of the river on the upgradient side of the plume, but TCE also was detected at numerous locations in the center and eastern bank of the river. The TCE plume discharges to the river where fine-grained glaciomarine sediments of the Presumpscot Formation are absent and where coarse-grained facies of buried glaciomarine fan deposits provide a pathway for ground-water flow. Based on results of analyses of vapor-diffusion samples and other previous studies, the plume appears to pass under and beyond the river near Boiling Springs and along the river for about 300 feet downstream from the sand boils. A coarse-grained, organic-rich layer at the base of the alluvial flood plain sediments is confined by overlying fine-grained alluvial sediments and may provide a conduit for ground-water leaking upward from buried glaciomarine fan deposits. INTRODUCTION A plume of trichloroethylene (TCE) in ground water that originated at the McKin Superfund Site in Gray, Maine, extends about 4,000 ft eastward to the Royal River (Sevee & Maher Engineers, Inc., 1989; 1993; 1998; 1999). Because TCE concentrations in the Royal River often exceed the State of Maine’s water- quality standard of 2.7 μg/L (Tetra Tech NUS, Inc., 1998), a remediation program may be needed to limit the discharge of TCE to the river. Selection of a reme- diation program requires an understanding of the configuration of the TCE plume near the river, the distribution of TCE concentrations across the width of the plume, and geologic conditions that affect ground- water discharge into the Royal River. During the autumn of 1997, the U.S. Geological Survey (USGS), in cooperation with the U.S. Environ- mental Protection Agency (USEPA), used vapor-diffu- sion samplers to determine the extent of the TCE plume in ground water near the Royal River and variations in TCE concentrations across the width of the plume. During subsequent studies in the spring and summer of 1998, the distribution of geologic materials near the river was examined to help identify pathways for TCE in ground water. In addition, available hydrologic and geologic information from previous investigations was synthesized with results of vapor-diffusion sampling and collection of geologic information. This report presents the results of the vapor-diffusion sampling and a discussion of potential geologic controls on contami- nant pathways. DESCRIPTION OF STUDY AREA The study area is along the flood plain of the Royal River in Gray, Maine, about 4,000 ft east and

DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC CONTROLS ON CONTAMINANT PATHWAYS NEAR THE ROYAL RIVER, MCKIN SUPERFUND SITE AREA, GRAY, MAINE

By F.P. Lyford, L.E. Flight, Janet Radway Stone, and Scott Clifford

-

it e-

f d-

l n-u-

e in

of

E d s

nd i-

ABSTRACT

Vapor-diffusion samplers were used in the autumn of 1997 to determine the lateral extent and distribution of concentrations of a trichloroeth-ylene (TCE) plume in the ground-water discharge area near the McKin Superfund Site, Gray, Maine. Analyses of vapor in the samplers identified a plume about 800 feet wide entering the river near Boiling Springs, an area of ground-water discharge on the flood plain of the Royal River. The highest observed concentration of TCE in vapor was in an area of sand boils on the western bank of the river and about 200 feet downstream from Boiling Springs. Previous studies showed that most of the TCE load in the river originated in the area of the sand boils. In general, highest concentrations were observed on the western side of the river on the upgradient side of the plume, but TCE also was detected at numerous locations in the center and eastern bank of the river.

The TCE plume discharges to the river where fine-grained glaciomarine sediments of the Presumpscot Formation are absent and where coarse-grained facies of buried glaciomarine fan deposits provide a pathway for ground-water flow. Based on results of analyses of vapor-diffusion samples and other previous studies, the plume appears to pass under and beyond the river near Boiling Springs and along the river for about 300 feet downstream from the sand boils. A coarse-grained, organic-rich layer at the base of the alluvial flood plain sediments is confined by overlying fine-grained alluvial sediments and may provide a conduit for ground-water leaking upward from buried glaciomarine fan deposits.

INTRODUCTION

A plume of trichloroethylene (TCE) in ground water that originated at the McKin Superfund Site in Gray, Maine, extends about 4,000 ft eastward to the Royal River (Sevee & Maher Engineers, Inc., 1989; 1993; 1998; 1999). Because TCE concentrations in the Royal River often exceed the State of Maine’s waterquality standard of 2.7 µg/L (Tetra Tech NUS, Inc., 1998), a remediation program may be needed to limthe discharge of TCE to the river. Selection of a remdiation program requires an understanding of the configuration of the TCE plume near the river, the distribution of TCE concentrations across the width othe plume, and geologic conditions that affect grounwater discharge into the Royal River.

During the autumn of 1997, the U.S. GeologicaSurvey (USGS), in cooperation with the U.S. Enviromental Protection Agency (USEPA), used vapor-diffsion samplers to determine the extent of the TCE plumin ground water near the Royal River and variations TCE concentrations across the width of the plume. During subsequent studies in the spring and summer1998, the distribution of geologic materials near the river was examined to help identify pathways for TCin ground water. In addition, available hydrologic angeologic information from previous investigations wasynthesized with results of vapor-diffusion samplingand collection of geologic information. This report presents the results of the vapor-diffusion sampling aa discussion of potential geologic controls on contamnant pathways.

DESCRIPTION OF STUDY AREA

The study area is along the flood plain of the Royal River in Gray, Maine, about 4,000 ft east and

ABSTRACT 1

Page 2: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

200 ft lower in altitude than the McKin Superfund Site (fig. 1). The flood plain along the river is largely forested with hardwood and softwood trees as well as a dense shrub layer in places. Some abandoned agricul-tural fields also are in or adjacent to the flood plain. Ground-water discharge points were apparent at several locations on the western bank of the river. The most prominent ground-water discharge point is a spring on the western bank of the river, known locally as Boiling Springs (fig. 2). Ground-water discharge is also evident in an area of sand boils located approxi-mately 10 ft upstream from the confluence of the unnamed tributary with the Royal River.

The McKin Superfund Site is a former waste collection, transfer, and disposal facility that operated from 1965 to 1978. The McKin Superfund Site and study area are in a rural setting of farmland, woodland, and single-family homes. Most homes in the area were supplied by individual wells completed in bedrock until contaminants were detected in ground water. Since 1978, residents have received their water from a public-supply system (U.S. Environmental Protection Agency, 1992).

Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period October 1, 1949 to September 30, 1996 was 273 ft3/s (Nielsen and others, 1997, p. 115). Streamflow near the study area typically is about 55 percent of streamflow at Yarmouth (John Sevee, Sevee & Maher Engineers, Inc., written commun., 1997).

DATA COLLECTION AND ANALYSIS

Study methods included the installation of vapor-diffusion samplers to determine discharge areas along the Royal River for the TCE plume in ground water, on-site analysis of vapors in the diffusion samplers, synthesis of available hydrologic and geologic information, ground-penetrating-radar surveys along the flood plain of the Royal River, and manual installation of auger holes through alluvial sediments.

Construction and Analysis of Vapor-Diffusion Samplers

Vapor-diffusion samplers were constructed using the method described by Vroblesky and Hyde (1997).

The samplers consist of a 40-mL, uncapped air-filled glass bottle wrapped in two polyethylene bags held in place with cable ties. A duplicate sample for quality control was constructed by placing an additional poly-ethylene-wrapped glass bottle in the outer bag. The sampler was attached to a survey flag for marking and retrieval. When placed in water or saturated sediments containing volatile organic compounds (VOCs), organic vapors diffuse through the two layers of poly-ethylene and equilibrate with air in the bottle. The time required for equilibration is 24 hours or less in a controlled setting (Vroblesky and others, 1996; Vrob-lesky and Hyde, 1997). Additional time may be required after placement of the samplers to allow concentrations of VOCs in ground-water to re-equili-brate in disturbed materials; a period of 2 weeks is recommended (Don Vroblesky, U.S. Geological Survey, oral commun., 1997). After retrieving the sampler, the outer bag is removed to shed attached sedi-ment, and a cap is immediately screwed onto the bottle over the inner bag.

Vapor-diffusion samplers were installed at 156 locations (fig. 2) using one of two methods. Most were installed about 6 to 8 in. into the river-bottom sedi-ments by penetrating the bottom sediments with a narrow-bladed shovel, forcing the shovel forward, and inserting the sampler in the gap that was formed between the shovel and sediment. The type of sediment each sampler was placed in was recorded. At about 20 percent of the locations, the river was too deep to use this method. In these locations, a driver method was used in which a steel pipe outfitted with an inner blocked pipe was driven into the sediment with a hand-held slide hammer. The inner pipe was then removed and the sampler was inserted to the bottom of the outer pipe. Finally, the outer pipe was removed leaving behind the sampler, and sediments were allowed to collapse around the sampler. Samplers installed by the driver method were typically about 1 ft into the river-bottom sediments.

Samplers were placed every 50 ft along the western bank of the river (fig. 2) starting about 800 ft upstream from the mapped edge of the TCE plume (fig. 1) (Sevee & Maher Engineers, Inc., 1993). The spacing was reduced to 25 ft from the area of Boiling Springs to the Maine Central Railroad trestle (fig. 2).

2 Distribution of Trichloroethylene and Geologic Controls on Contaminant Pathways near the Royal River, McKin Superfund Site Area, Gray, Maine

Page 3: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

Figure 1. Location of McKin Superfund Site, study area, extent of trichloroethylene in ground water, and potentiometric surface contours for the surficial aquifer, Gray Maine.

120

43 53'30"o

McKin

Site

Base from U.S. Geological SurveyDigital line graphs from Grayquadrangle 1:24,000

Contour interval 10 feetNational Geodetic Vertical Datum of 1929

97

94

95

96

93

92

100

11

0

120

140160

180

220

200

240

280

2605

5

5

5

Location ofstudy area

MAINES

Ct

vr

.

roixRie

0

0

40

50

80 MILES

100 KILOMETERS

45

44

71

70

69 68

67

43

o

o

o

o

o

o

o

o o

o

47

46

St. JohnveRi r

Augusta

Atlantic

Ocean

Portland

Roy

alR

iver

BoilingSprings

Unnamed Tributary

Depot Road

Ma

yall

Ro

ad

Gray Station

115

Collyer Brook

East Gray

70 17'30"o

70 16'30"o

43 53'o

Route

Main

eC

entr

al R

ailr

oad

250

150

150

150

150

300

300

100

100

200

200

200

200

POTENTIOMETRIC CONTOUR -

WATERBODIES

EXTENT OF TRICHLOROETHYLENE IN SURFICIAL AQUIFER - Showsthe extent of concentrations greater than 5 micrograms per liter.(Data from Sevee and Maher Engineers, Inc., 1998.)

Shows altitude at which waterlevels stood in tightly cased wells completed in surficialmaterials in May 1998. Contour interval is variable. Datum is sealevel. (Data from Sevee and Maher Engineers, Inc., 1998.)

0

0

500

100 300 METERS200

1,000 FEET

Area shown in figure 2

DATA COLLECTION AND ANALYSIS 3

Page 4: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

70 16'40"o70 17’

o

Figure 2. Location of vapor-diffusion samplers placed along and near the Royal River (September and October 1997),ground-penetrating-radar surveys, and manual-auger holes.

Vapor-diffusion sampler and selected site identifiers73C

EXPLANATION

Ma

ine

Ce

ntra

l Ra

ilro

ad

150

150

150

150100

100

100

150

200

100

Location of ground-penetrating-radar surveys and manual auger holes

39R

39T10

39T6

39T1

Unnamed Tributary

BoilingSprings

25R

30C

35R37R

20R

76C

73C

70C

10R

1R

5R

15R14R

55L52S 53S

50R

45L

40R 65R61S60R

0

0 50 METERS

200 FEETBase from U.S. Geological SurveyDigital line graphs from Grayquadrangle 1:24,000

43 53'o

43 53'20”o

Roy

alR

iver

Area shown in figure 6

Bs1Bs2Bs3

Contour interval 10 feet

National Geodetic Vertical Datum of 1929

4 Distribution of Trichloroethylene and Geologic Controls on Contaminant Pathways near the Royal River, McKin Superfund Site Area, Gray, Maine

Page 5: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

g

ted s

y as n- s

g n

). ic ,

i-

a th

al d

Samplers also were placed in the center and eastern bank of the river at many locations. The distance between samplers was expanded to 50 ft, 100 ft, and 200 ft downstream from the trestle. Near the sharp downstream bend in the river and beyond, samplers were placed only near the center of the river channel. Locations shown on figure 2 were determined on the basis of measured distances along the western bank of the river and the features apparent on the base map. The locations shown are estimated to be within 20 ft of actual locations.

Vapor-diffusion samplers also were placed along the unnamed tributary that enters the Royal River from the west near the first sharp bend, in Boiling Springs, and in seepage areas in two other locations near the river. Samplers in the unnamed tributary stream, which was typically 2 to 3 ft wide, were placed at distances of 50 ft and 100 ft in the center of the channel.

The vapor-diffusion samplers were retrieved by pulling the attached wire flag. Within minutes of retrieval, the outer polyethylene bag was removed and a cap was placed on the bottle over the inner bag. The inner bag was then cut away and the bottle was labeled.

Vapor-diffusion samples were analyzed on site for TCE using USEPA Region I standard air screening method (U.S. Environmental Protection Agency, 1998). Samples were analyzed within 4 hours of sample collection using Photovac gas chromatographs equipped with 4-ft by 1/8-in. SE-30 columns and photo-ionization detectors. TCE was the target compound for the vapor sample analyses. The reporting limit for TCE using this equipment and method was 8 ppb by volume.

Collection of Geologic Information

A combination of ground-penetrating radar (GPR), manually installed auger holes, and existing geologic information was used in this study. The geologic information collected from the GPR surveys and manual-auger holes was integrated and synthesized with existing geologic information from published geologic maps and logs of wells and test borings. This information was used to examine possible geologic controls on contaminant pathways where the plume discharges into the Royal River and to construct geohy-drologic sections.

GPR surveys were completed in April 1998 to determine the underlying surficial geology along the Royal River. GPR transmits radio-frequency electro-

magnetic pulses into the ground from antennas. The signal reflects off materials in the subsurface back to the antennas and then the data are processed and displayed as a graphic image. A GPR traverse was run with a 300-Mhz and a 100-Mhz transmission-frequency antenna along the western bank of the Royal River from the railroad trestle west and north to approximately 100 ft upstream from Boiling Springs. The traverse ranged in distance from 5 to 50 ft from the river’s edge (fig. 2).

Nine manual-auger holes were completed alonthe GPR traverse (fig. 2) to interpret the GPR recordand to better determine the underlying surficial geology of the study area along the Royal River. Sedi-ment types were recorded and samples were collecwhen a change in sediment type was observed. Logmade from the manual-auger holes were used to construct geohydrologic cross sections and were synthesized with existing geologic information.

GEOHYDROLOGY OF THE REGION AND STUDY AREA

The surficial geology and hydrology of the studarea along the Royal River and surrounding region (shown in fig. 3) are important to understanding potetial TCE discharge areas along the Royal River. Muchof the information discussed in the following sectionis a synthesis of existing information from previous investigations as well as from observations and datacollected during this study.

Surficial Geology of the Region and Study Area

The surficial materials in the region surroundinthe study area and the McKin Superfund Site is showin figure 3; this map is modified from the surficial geologic map of the Gray quadrangle (Weddle, 1997Surficial materials in this area are underlain by granitbedrock of the Sebago pluton (Creasy and Robinson1997). Logs of wells and test borings (Sevee and Maher, 1989; 1998; Tetra Tech NUS, Inc., 1998) indcate that the bedrock surface lies at depths of 50 to 100 ft beneath the eastern edge of the glaciomarine deltand slopes eastward toward the Royal River to a depof nearly 200 ft beneath surficial materials. The verticdistribution and thickness of coarse- and fine-graine

GEOHYDROLOGY OF THE REGION AND STUDY AREA 5

Page 6: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

Figure 3. Surficial geology near the McKin Superfund Site.

0

0

500

100 300 METERS200

1,000 FEET

Base from U.S. Geological SurveyDigital line graph from Grayquadrangle 1:24,000

Geology modified from Weddle (1997)

DD’

A

C'

C

B'

A'

GWD-2

B-102MW-01

MW-03

MW-212

MW-206

B-3

B-2

B-5

B-4B-1

MW-202

B-103

B-104

401

403

MW-207

MW-203

MW-801

MW-802

MW-204

MW-205

Contour interval 10 feet

National Geodetic Vertical Datum of 1929

43 53'30"o

70 17'30"o

70 16'30"o

43 53'o

MW-803

B

Depot Road

Ma

yall

Ro

ad

Gray Station

Route 115

Roy

alR

iver

Collyer Brook

East Gray

Unnamed Tributary

McKinsite 250

150

150

150

150

300

300

100

100

200

200

200

200

6 Distribution of Trichloroethylene and Geologic Controls on Contaminant Pathways near the Royal River, McKin Superfund Site Area, Gray, Maine

Page 7: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

EXPLANATION

Figure 3. Surficial geology near the McKin Superfund Site—Continued.

POSTGLACIAL DEPOSITS

MAP SYMBOLS

Contact between map units

A A

Glaciomarine Deposits, fine-grained -- Massive to finely laminated, graysilty clay with minor amounts of fine sand and sparse fossil marine molluskshells and ice-rafted dropstones; deposited in the deeper water glaciomarineenvironment, distal from the ice margin. Where sediment has been oxidized inthe upper part of section, the color is dark olive gray. This unit is the Presump-scot Formation of Bloom (1960;1963). In some places the upper 5-10 ft of unitis finely laminated to massive, silty fine to medium sand; deposited in the shal-low glaciomarine environment during regression of the sea.

Flood Plain Alluvium-- Silt, sand and gravel, with variable amounts oforganic material on the flood plains of the Royal River, Collyer Brook, and theUnnamed Tributary; deposits are 10-12 ft thick along the Royal River, thinneralong smaller streams; alluvium overlies thicker glacial materials in mostplaces.

Location of geologic section line; section shown in figures 4 and 5

Glaciomarine Deposits, coarse-grained-- Well to poorly sorted gravel, sandand gravel, sand, and local diamict sediment laid down as deltaic and subaque-ous fan deposits in contact with the glacier margin during retreat of the icesheet in the glacial sea. Deposits are coarse-grained, poorly sorted, and bed-ding is collapsed in ice-proximal (northerly) parts; sediments are finer grained,better sorted, and beds generally dip southerly farther from (distal to) the ice-margin position; in distal parts of the deposits, fan and delta sediments interfin-ger with fine-grained glaciomarine sediments. Coarse-grained fan deposits arepresent beneath fine-grained deposits in much of the area west of the McKinSuperfund Site.

Glacial Till-- Nonsorted and nonstratified, compact mixture of grain sizesranging from clay to large boulders; matrix is largely fine sand containing upto 25 percent silt and clay; deposited beneath glacial ice. Locally, a less com-pact, sandy, stony facies of till may overlie the more compact facies. In themap area, till is present at land surface in only two small areas; it forms a thinblanket over bedrock in most places in the subsurface.

Location of wells and test borings; numbers as reported in Sevee and Maher, Engineers Inc., 1998

MW-802

GLACIAL DEPOSITS

Artificial fill of railroad and road embankments

Waterbodies

GEOHYDROLOGY OF THE REGION AND STUDY AREA 7

Page 8: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

surficial materials along a west-to-east line (A-A’) and a south-to-north line (B-B’) are shown in figures 4a and 4b. Sections C-C’ and D-D’ (figs. 5a and 5b) are large-scale vertical sections along and across the flood plain of the Royal River near Boiling Springs. All geohydro-logic sections were constructed using available well, test hole, and manual-auger data, as well as existing geologic information and geologic interpretation.

The altitude of the glaciomarine sea level in the Gray area is marked by the Gray and East Gray deltas, which have a surface altitude of 305 to 315 ft; the East Gray delta has a measured topset-foreset contact recording sea level at 289 ft (Weddle, 1997). The McKin Superfund Site is near the eastern edge of the East Gray glaciomarine delta, which forms a relatively flat (locally kettled) surface north, west, and south of the contamination site. The delta is composed of layered sand and gravel that can be seen in excavations west and northwest of the McKin Superfund Site. A gravel pit west of Depot Road reveals delta foreset bedding that dips southwestward. Logs of wells and test borings at the McKin Superfund Site indicate that the coarsest grained delta deposits lie north-northeast of the site. The East Gray delta was built from an ice-margin position along its northeastern edge (Weddle, 1997). A bouldery ridge and hummocky topography on both sides of Depot Road northeast of East Gray may be part of an esker system that supplied sediment to the delta during its construction.

Fine-grained glaciomarine sediments (Presump-scot Formation) are present at land surface in most places at and below 240 ft altitude east of the McKin Superfund Site. This material consists of massive to finely laminated, gray to dark-bluish gray silt, clay, and minor fine sand that locally interfingers with the coarse-grained facies but mostly overlies it. The glaciomarine silt and clay ranges from a few to more than 100 ft in thickness. The permeability of these glaciomarine sediments is extremely low; if this mate-rial comprised the entire thickness of surficial materials in this area, ground-water flow toward the Royal River would be severely impeded. As seen in sections A-A’ and B-B’ (fig. 4a and 4b), however, coarse-grained materials of variable thickness underlie the marine silt and clay in most places east of the McKin Superfund Site (Weddle, 1997). This coarse-grained material consists of sand, gravel, and local diamict sediment deposited as subaqueous fans associated with NW-SE trending ice-margin positions from which the East Gray delta was built. The fan deposits are coarse

grained in ice-proximal (northerly) directions and grade to finer gravel and sand within short distances in distal (southerly) directions. The distal sandy beds interfinger with fine-grained marine silt and clay. Subsurface data indicate that the cores of successive fan deposits lie beneath glaciomarine sediments in the 155- to 170-ft knoll south of the unnamed tributary and the 155-ft knoll north of the tributary. These highly permeable coarse-grained glaciomarine deposits in the subsurface east of the McKin Superfund Site provide a preferential pathway for ground-water discharge to the Royal River.

The irregular surface of glaciomarine silt and clay deposits (figs. 4a and 4b) is a result of erosion and downcutting in postglacial time by the Royal River, Collyer Brook, and many tributary streams and ephem-eral-stream gullies. In some places, where the surface of coarse-grained material is at higher altitudes, post-glacial streams have cut through the entire section of fine-grained sediment, leaving coarse-grained mate-rials at or near land surface. Such is the case in a section in the modern flood plain along the western side of the Royal River near Boiling Springs (fig 5b).

Hydrology of the Region and Study Area

Ground water in the immediate vicinity of the McKin Superfund Site, as indicated by potentiometric contours and the plume map shown in figure 1, flows northward toward the intersection of Mayall and Depot Roads. Most of the flow then turns eastward toward the Royal River. Some of the flow near Mayall and Depot Road, however, continues northeastward toward Collyer Brook and eventually turns eastward toward the Royal River (Sevee & Maher Engineers, Inc., 1998). In most of the area west of the area covered by the Presumpscot Formation (fig. 3), ground water in surficial materials is unconfined and the saturated thickness is generally less than 40 ft. Hydraulic gradi-ents are steep in this area (fig. 1), and the water table approximately parallels a steeply sloping bedrock surface (fig. 4a). Conceptually, the configuration of the bedrock surface serves as a major control on ground-water-flow patterns (Sevee & Maher Engineers, Inc., 1989). The potentiometric surface for shallow bedrock is similar to the potentiometric surface for the surficial aquifer (Sevee & Maher Engineers, Inc., 1989).

In the area where the Presumpscot Formation is present, thick, buried coarse-grained sediments are found in places, and ground water in these coarse-

8 Distribution of Trichloroethylene and Geologic Controls on Contaminant Pathways near the Royal River, McKin Superfund Site Area, Gray, Maine

Page 9: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

Figure 4a. Geohydrologic section A-A’ near the McKin Superfund Site, Gray, Maine. (Location of section line shown on fig. 3.)

Bend

inse

ctio

n

Bend

inse

ctio

n

Bend

inse

ctio

n

Bend

inse

ctio

n

VERTICAL EXAGGERATION X 10

400

West

E. GrayDelta

East

300

-100

0

100

200

Granite(Sebago Pluton)

Former Sea Level

Roya

lRiv

er

MW

-01

Bend

inse

ctio

n

B-1

02

MW

-803

B-4

B-3

MW

-206-P

roje

cted

A A’

B-1

ALT

ITU

DE

,IN

FE

ET

Bedding shown schematically

0

500

100 300 METERS200

1,000 FEET0

Glacial till

EXPLANATION

Granite

POTENTIOMETRIC SURFACE IN

SURFICIAL AQUIFER - Water levels

measured in May 1998 (Sevee and

Maher, Engineers Inc., 1998) dashed

where estimated

Silt and clay

Silt - fine sand facies

Coarse sand - fine gravel facies

Sand and gravel

Sand

GEOHYDROLOGY OF THE REGION AND STUDY AREA 9

Page 10: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

Figure 4b. Geohydrologic section B-B’ near the McKin Superfund Site, Gray, Maine. (Location of section line shown on fig. 3.)

200

100

0

B-

103

pro

ject

ed

MW

-01

MW

-03

Boili

ng

Springs

MW

-204 GW

D-2

Colly

er

Bro

okU

nnam

ed

Tributa

ry

-100

South North

ALT

ITU

DE

,IN

FE

ET

B B’

Bend

inse

ctio

n

Bend

inse

ctio

n

Bend

inse

ctio

n

Granite(Sebago Pluton)

VERTICAL EXAGGERATION X 10

C’C

0

500

100 300 METERS200

1,000 FEET0

Bedding shown schematically

Glacial till

EXPLANATION

Granite

POTENTIOMETRIC SURFACE IN

SURFICIAL AQUIFER - Water levels

measured in May 1998 (Sevee and

Maher, Engineers Inc., 1998) dashed

where estimated

Silt and clay

Silt - fine sand facies

Coarse sand - fine gravel facies

Sand and gravel

Sand

10 Distribution of Trichloroethylene and Geologic Controls on Contaminant Pathways near the Royal River, McKin Superfund Site Area, Gray, Maine

Page 11: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

A2

-300

A2

-4

00

D-

D’

NorthwestC’

VERTICAL EXAGGERATION X 5

GE

OH

YD

RO

LO

GY

OF

TH

E R

EG

ION

AN

D S

TU

DY

AR

EA

11

100

80

60

40

20

A1

-90

A1

-155

A1

-2

80

A1

-350

Un

na

med

Trib

uta

ry

Ben

din

Sectio

n

MW

-01

MW

-02

MW

-03

A2

-20

A2

-1

00

A2

-17

0

ALT

ITU

DE

,IN

FE

ET

GPR Line

CSoutheast

0

500

100 300 METERS200

1,000 FEET0

Bedding shown schematically

EXPLANATION

POTENTIOMETRIC SURFACE IN SURFICIAL

AQUIFER - Water levels measured in May 1998

(Sevee and Maher, Engineers Inc., 1998) dashed

where estimated

Silt and clay

Silt - fine sand facies

Coarse sand - fine gravel facies

Sand and gravel

Sand

Figure 5a. Geohydrologic section C-C’ near Boiling Springs, Gray, Maine. (Location of section line shown on fig. 3.)

Page 12: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

VERTICAL EXAGGERATION X 5

ound-water flow projected

D’East

n schematically

TION

TRIC SURFACE IN

UIFER - Water levels

ay 1998 (Sevee and

ers Inc., 1998) dashed

ed

facies

fine gravel facies

vel

12D

istribu

tion

of T

richlo

roeth

ylene an

d G

eolo

gic C

on

trols o

n C

on

tamin

ant

Path

ways n

ear the R

oyal R

iver, McK

in S

up

erfun

d S

ite Area, G

ray, Main

e

Direction of gr

onto page

Predominant ground-water

flow direction is southward

40

60

100

120

140

160

80

803

Pro

jecte

d

B-

10

2

Pro

jecte

d

MW

-03

Pro

jecte

d

A2-3

00

C-C

Bo

ilin

gS

prin

gs

Ro

yalR

ive

r

ALT

ITU

DE

,IN

FE

ET

DWest

1000

0 10 20 30 40 50 METERS

200 FEET

Bedding show

EXPLANA

POTENTIOME

SURFICIAL AQ

measured in M

Maher, Engine

where estimat

Silt and clay

Silt - fine sand

Coarse sand -

Sand and gra

Sand

Figure 5b. Geohydrologic section D-D’ near Boiling Springs, Gray, Maine. (Location of section line shown on fig. 3.)

Page 13: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

grained deposits is confined by silt and clay of the Presumpscot Formation. The hydraulic gradients decrease appreciably (fig. 1) from about 0.1 in the unconfined part of the aquifer to about 0.003 in the confined part of the aquifer. The change in gradient can be attributed mainly to increased transmissivity caused by increased aquifer thickness in the area of the buried valley. Figure 1 shows a potentiometric low for the ground-water system where the river turns abruptly eastward. Boiling Springs (fig. 1) and sand boils down-stream from Boiling Springs and a few feet upstream from the unnamed tributary in the western bank of the Royal River are evidence of ground-water discharge in this area.

The unnamed tributary flows perennially for several hundred feet upstream from its mouth. Because the altitude of this stream, as determined from topo-graphic contours in figure 1, is above the potentio-metric surface, except possibly near its confluence with the Royal River, perennial flow is most likely derived from ground-water discharge from coarser facies (silts and fine sands) of the Presumpscot Formation.

The plume of TCE in the surficial aquifer and fractured crystalline bedrock currently underlies several hundred acres and extends to the Royal River to the east (fig. 1); concentrations of TCE in ground water near the McKin Superfund Site in May 1998 were generally less than 2,700 µg/L (Sevee & Maher Engi-neers, Inc., 1998). The highest concentrations were along a band that extended from an area north of the McKin Superfund Site eastward toward the Royal River. The extension of the plume to the north may have been induced by pumping residential wells prior to installation of a public-supply system (Sevee & Maher Engineers, Inc., 1999).

Vertical profiling of water quality in surficial materials based on water samples from small-diameter wells along the flood plain of the Royal River between the unnamed tributary and Boiling Springs in March and April 1998 detected TCE in the coarse-grained sediments at most depths above the bedrock surface (Tetra Tech NUS, Inc., 1998). The highest concentra-tions of TCE exceeded 1,000 µg/L along a 200-ft wide band between the unnamed tributary and Boiling Springs. The band was 25 ft or less in thickness and rose from a depth of about 50 ft near the unnamed trib-utary to 10 ft at a distance of about 200 ft south of Boiling Springs. TCE concentrations in water from small-diameter wells placed at Boiling Springs were 300 µg/L or less (Tetra Tech NUS, Inc., 1998).

Loads of TCE in the Royal River downstream from the mapped plume were estimated to be about 0.8 kg/d in early 1999 (Sevee & Maher Engineers, Inc., 1999). Measurements of TCE were made during different flow conditions of the Royal River. No detec-tions of TCE in river water were reported from sites upstream from Boiling Springs. TCE, however, was detected at the inflow point from Boiling Springs, and a sharp increase in concentration was observed near the mouth of the unnamed tributary and the bend in the river. There was no change in detections at high stream-flows and a gradual decrease at low streamflows for several thousand feet downstream from the railroad trestle (John Sevee, written commun., 1997).

DISTRIBUTION OF TRICHLOROETHYLENE FROM VAPOR-DIFFUSION SAMPLERS

Analysis of vapor identified a plume about 800 ft wide entering the Royal River. Results of vapor anal-yses are given in table 1, and concentrations for the plume edge are shown in figure 6. TCE was detected in most vapor-diffusion samples placed in or near the Royal River downstream from sampler 14R, (fig. 2) which was near the northern edge of the mapped plume area. The highest concentration of TCE (30,400 ppb by volume) was in sampler 37R (fig. 2), which was collected from a sand boil on the western bank of the river approximately 270 ft downstream from Boiling Springs. TCE was not detected in several samples from the middle of the river near Boiling Springs where concentrations of at least 500 ppb by volume were detected in samples from each bank. TCE concentra-tions of less than 500 ppb by volume were observed in samples downstream from the unnamed tributary from the western bank and center of the river bend; clays of the Presumpscot Formation were apparent in the river bottom in this area. Concentrations exceeded 500 ppb by volume in some samples between the river bend and the railroad trestle. TCE was detected in all samples downstream from the railroad trestle, but most concen-trations were below 500 ppb by volume.

Vapor-diffusion samples collected at three loca-tions in Boiling Springs had TCE concentrations of 4,230 to 7,100 ppb by volume. One of two samples from a seepage area on the eastern side of the river between the river bend and railroad trestle had a TCE concentration that exceeded 500 ppb by volume. The TCE concentration from sampler 61S from a spring on

DISTRIBUTION OF TRICHLOROETHYLENE FROM VAPOR-DIFFUSION SAMPLERS 13

Page 14: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

Table 1. Concentrations of trichloroethylene (TCE) from vapor-diffusion samplers collected near the Royal River, Gray, Maine, September to October 1997

[Samplers were placed during September 22 to 24, 1997 and removed and analyzed for TCE from October 6 to 9, 1997. All distances were measured along the western bank of the Royal River. Units for TCE concentrations in vapor are parts per billion by volume (ppb by volume). Samplers were labelled with an “R” on the western (right) bank, with a “C” in the center stream, and with an “L” on the eastern (left) bank. Samplers were labelled with a “T” on the unnamed tributary and with a “S” in a spring area. “ND” refers to nothing detected above the lower reporting limit (8 parts per billion by volume) for TCE using a Photovac gas chromatograph unit. The symbol “- -” means that vapor-diffusion samplers were not placed in these loca-tions. Bottom material descriptions separated by slashes refer to the western bank, center stream, and eastern bank, respectively]

Vapor-diffusion sampler

Distance from origin

(feet)1

TCE concentration in vapor (parts per billion by volume)

Bottom materialsWestern

bankCenter stream2

Eastern bank

1R 0 ND - - - - silt

2R 50 ND - - - - silt

3R 100 ND - - - - silt

4R 150 ND - - - - silt

5R 200 ND - - - - silt

6R 250 ND - - - - silt

7R 300 ND - - - - silt

8R 350 ND - - - - silt

9R 400 ND - - - - silt

10R/10C/10L 450 ND ND ND silt

11R 500 ND - - - - silt

12R 550 ND - - - - silt

13R/13C/13L 600 ND ND ND silt/ sand/ silt

14R 650 95 - - - - silt

15R 700 1,390 - - - - cobbles/ boulders

16R 725 27 - - - - silt

17R/ 17C/ 17L 750 114 1,300 14 silt/ fine sand/ silt

18R 800 6,870 - - - - silt

19R 850 2,290 - - - - fine sand

20R/ 20C/ 20L 900 6,320 1,600 46 silty sand/ sand/ silt

21R 950 4,060 - - - - sand and mud

22R 1,000 4,260 - - - - silty sand

23R/ 23C/ 23L 1,050 2,840 4,260 2,840 silt/ sand/ silt

24R/ 24C/ 24L 1,100 2,430 ND 4,260 fine sand/ sand/ sand

25R/ 25C/ 25L 1,150 8,930 ND 1,470 silt/ sand/ sand

26R/ 26C/ 26L 1,175 7,200 ND 1,620 silt/ sand/ silt

27R/ 27C/ 27L 1,200 9,940 ND 5,480 silt/ sand/ fine sand

28R/ 28C/ 28L 1,225 203 ND 5,380 silt/ sand/ sandy silt

29R/ 29C/ 29L 1,250 1,220 18 3,250 silt/ sand/ silty sand

30C/ 30L 1,275 - - 16 22 silt/ silty sand

31R/ 31C/ 31L 1,300 710 7,200 4,060 silty sand/ sand/ silt

32R/ 32C/ 32L 1,325 18,300 8,320 4,360 fine sand/ sand/ silt

33R/ 33C/ 33L 1,350 19,450 14,700 14,900 fine sand/ sand/ silt

34R/ 34C/ 34L 1,375 12,700 10,400 5,370 silt/ sand/ silt

35R 1,370 13,240 - - - - silt

36R/ 36C/ 36L 1,400 13,700 8,110 4,600 silt/ coarse sand/ silt

37R 1,417 30,400 - - - - silt and fine gravel

14 Distribution of Trichloroethylene and Geologic Controls on Contaminant Pathways near the Royal River, McKin Superfund Site Area, Gray, Maine

Page 15: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

38R/ 38C/ 38L 1,425 19,100 13,400 1,060 sand/ coarse sand/ silty sand

39R 1,438 15,200 - - - - sand with gravel

40R/ 40C/ 40L 1,450 15,700 2,450 4,670 sand and gravel/ gravel/ fine sand

41R/ 41C/ 41L 1,475 20 10,500 3,040 silt/ gravel/ sand and gravel

42R/ 42C 1,500 218 154 - - clay/ sand and gravel

43R/ 43L 1,525 89 - - 3,400 clay/ sand

44R/ 44C/ 44L 1,550 105 65 4660 cobbles over sand/ clay/ gravel bar

45R 1,575 145 - - - - clay

46R/ 46C/ 46L 1,600 84 243 3,140 gravel over sand/ gravel/ fine gravel

47R 1,625 27 - - - - silt

48R 1,650 8 - - - - silt

49R/ 49C/ 49L 1,675 13,800 8,320 4,560 coarse sand/ sand/ fine/medium sand

50R 1,700 1,680 - - - - gravel

51R/ 51C/ 51L 1,725 2,960 428 2,860 gravel/ gravel/ sand

52R/ 52C/ 52L 1,750 316 1,460 8 sand/ gravel/ silt

52S 1,750 - - - - 954 silt

53R/ 53L 1,775 1,000 - - ND silty sand/ silt

53S 1,775 - - - - 22 silt

54R/ 54L 1,800 2,610 - - 1,380 sand/ silt

55R/ 55C 1,825 2,610 877 - - silty sand/ coarse sand

56R 1,850 522 - - - - silty sand

57R/ 57C/ 57L 1,875 9,290 159 23 coarse sand/ sand/ sand

58R 1,900 ND - - - - coarse sand

59R 1,925 459 - - - - gravel

60R/ 60C/ 60L 1,950 1,570 4,180 ND sand/ gravel/ sand

61R 1,975 ND - - - - sand

61S 1,975 8 - - - - silt

62R 2,000 375 - - - - sand

63R/ 63C/ 63L 2,050 8 39 21 sand/ sand over clay/ silt with clay

64R/ 64C/ 64L 2,100 256 100 8 silt and sand/ sand and gravel/ silt

65R 2,150 33 - - - - clay

66R/ 66C/ 66L 2,200 101 254 355 clay/ cobbles/ gravel

67C 2,300 - - 436 - - gravel

68C 2,400 - - 28 - - sand

69C 2,500 - - 159 - - cobbles

70C 2,600 - - 480 - - gravel

71C 2,800 - - 84 - - clay

72C 3,000 - - 449 - - sand and gravel

73C 3,200 - - 188 - - sand

Table 1. Concentrations of trichloroethylene (TCE) from vapor-diffusion samplers collected near the Royal River, Gray, Maine, September to October 1997--Continued

[Samplers were placed during September 22 to 24, 1997 and removed and analyzed for TCE from October 6 to 9, 1997. All distances were measured along the western bank of the Royal River. Units for TCE concentrations in vapor are parts per billion by volume (ppb by volume). Samplers were labelled with an “R” on the western (right) bank, with a “C” in the center stream, and with an “L” on the eastern (left) bank. Samplers were labelled with a “T” on the unnamed tributary and with a “S” in a spring area. “ND” refers to nothing detected above the lower reporting limit (8 parts per billion by volume) for TCE using a Photovac gas chromatograph unit. The symbol “- -” means that vapor-diffusion samplers were not placed in these loca-tions. Bottom material descriptions separated by slashes refer to the western bank, center stream, and eastern bank, respectively]

Vapor-diffusion sampler

Distance from origin

(feet)1

TCE concentration in vapor (parts per billion by volume)

Bottom materialsWestern

bankCenter stream2

Eastern bank

DISTRIBUTION OF TRICHLOROETHYLENE FROM VAPOR-DIFFUSION SAMPLERS 15

Page 16: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

1 Vapor-diffusion samplers are listed in downstream order beginning approximately 1,150 feet upstream from the discharge point of Boiling Springs into the Royal River. Distance was measured along the western bank of the river only. Exceptions are 10 samplers placed along the unnamed tributary (labelled consecutively beginning with 39T) and 3 samplers placed in Boiling Springs (labelled with a “BS”), which appear at the end of the table.2 “Center stream” samplers were placed in the bottom of the river channel at half the channel’s width at that location.

74C 3,400 - - 386 - - coarse sand and gravel

75C 3,600 - - 29 - - gravel

76C 3,800 - - 21 - - sand

39T1 - - - - ND - - sand

39T2 - - - - ND - - sand and gravel

39T3 - - - - ND - - sand and gravel

39T4 - - - - ND - - sand and gravel

39T5 - - - - ND - - cobbles

39T6 - - - - ND - - sand

39T7 - - - - ND - - sand

39T8 - - - - ND - - sand

39T9 - - - - ND - - sand

39T10 - - - - ND - - fine sand and silt

BS1 - - 7,100 - - - - silt

BS2 - - 5,940 - - - - silt

BS3 - - 4,230 - - - - fine sand

Table 1. Concentrations of trichloroethylene (TCE) from vapor-diffusion samplers collected near the Royal River, Gray, Maine, September to October 1997--Continued

[Samplers were placed during September 22 to 24, 1997 and removed and analyzed for TCE from October 6 to 9, 1997. All distances were measured along the western bank of the Royal River. Units for TCE concentrations in vapor are parts per billion by volume (ppb by volume). Samplers were labelled with an “R” on the western (right) bank, with a “C” in the center stream, and with an “L” on the eastern (left) bank. Samplers were labelled with a “T” on the unnamed tributary and with a “S” in a spring area. “ND” refers to nothing detected above the lower reporting limit (8 parts per billion by volume) for TCE using a Photovac gas chromatograph unit. The symbol “- -” means that vapor-diffusion samplers were not placed in these loca-tions. Bottom material descriptions separated by slashes refer to the western bank, center stream, and eastern bank, respectively]

Vapor-diffusion sampler

Distance from origin

(feet)1

TCE concentration in vapor (parts per billion by volume)

Bottom materialsWestern

bankCenter stream2

Eastern bank

16 Distribution of Trichloroethylene and Geologic Controls on Contaminant Pathways near the Royal River, McKin Superfund Site Area, Gray, Maine

Page 17: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

Figure 6. Concentrations of trichloroethylene in vapor-diffusion samplers installed near Boiling Springs, Gray, Maine, September and October 1997.

100

100

100 1

00

0

0

200 FEET

50 METERS

Bs1

70 17’15”o

70 17’05”o

43 53’05”o

43 53’12”o

Roy

alR

iver

8 - 500 parts per billion by volume

Non-detect

Vapor-diffusion sampler and site identifier

EXPLANATION

> 5,000 parts per billion by volume

501 - 5,000 parts per billion by volume

Base from U.S. Geological SurveyDigital line graph from Grayquadrangle 1:24,000

Unnamed Tributary

39R

39T4

39T1

25R

Bs2

Bs3

30C

35R

20R

20R

55R

52S53S

50R

45L40R

65R61S60R

BoilingSprings

Mai

neC

entra

l Rai

lroad

Contour interval 10 feet

National Geodetic Vertical Datum of 1929

DISTRIBUTION OF TRICHLOROETHYLENE FROM VAPOR-DIFFUSION SAMPLERS 17

Page 18: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

the western side of the river near the railroad trestle was 8 ppb by volume. TCE was not detected in vapor-diffu-sion samplers from the unnamed tributary.

Concentrations of TCE in vapor with units of parts per billion by volume can be roughly compared with TCE concentrations in water with units of micro-grams per liter. The highest concentrations observed in water samples collected from nearby microwells in March to April 1998 were in the range of 1,200 to 1,500 µg/L (Tetra Tech NUS, Inc., 1998) as compared to 30,400 ppb by volume measured in vapor in sand boils in the Royal River. The concentration of TCE in a water sample from Boiling Springs collected on October 22, 1997 was 300 µg/L (John Sevee, written commun., 1998), as compared to 4,230 to 7,100 ppb by volume in three vapor samples collected during this study. These data indicate that concentrations in vapor in parts per billion by volume are about 20 times higher than the concentrations in water in micrograms per liter.

GEOLOGIC CONTROLS ON CONTAMINANT PATHWAYS NEAR THE ROYAL RIVER

Previously collected hydrogeologic and water-quality information contained in several reports for the study area, results from vapor-diffusion samplers, and results from new geologic investigations along the Royal River provide the basis for a discussion on potential geologic controls on contaminant pathways. Water-level data collected in May 1998 from wells near the river (Sevee & Maher Engineers, Inc., 1998) indi-cated that hydraulic heads in aquifer materials upstream from where the river is crossed by Depot Road were nearly 10 ft higher than river stage, and nearly 5 ft higher than river stage near Boiling Springs. Because of the head difference, ground water poten-tially discharges to the river throughout this approxi-mately 2,500-ft reach. The presence of fine-grained sediments of the Presumpscot Formation upstream from well MW-204 (fig. 4b), however, limits the flow of ground water to the river. Much of the ground water in the aquifer system discharges to the river down-stream from well MW-204, where the river has eroded through the Presumpscot Formation and into coarse-grained subaqueous fan deposits. The discharge rate may be further enhanced or focused in the area near Boiling Springs by the presence of a coarse-grained facies in the fan deposits that serve as a preferential pathway for ground-water flow. The width of the TCE

plume near the river, as shown by Sevee & Maher Engineers, Inc. (1993), and reaffirmed using vapor-diffusion samplers, appears to correlate with where the Presumpscot Formation is thin or absent.

The flood plain surface lies at 90 to 95 ft in alti-tude along the Royal River near Boiling Springs. GPR data collected along the western bank of the river and manual-auger holes drilled at nine locations along the GPR line (fig. 2) indicate that the postglacial river allu-vium beneath the flood plain is 10- to 12-ft thick and consists of two distinct facies along this reach of the river. Logs of microwells and test borings in this area (Tetra Tech NUS, Inc., 1998) also confirm the presence of two facies in the alluvium. The lower 2 to 5 ft of the alluvium is coarse to very coarse-grained sand and granule gravel with some layers of medium to coarse sand and fine to medium sand. This lower facies also contains large amounts of organic material including twigs, bark, pine cones, and finely disseminated organic fragments. Several of the manual-auger holes could not penetrate deeper than about 10 ft because buried logs were encountered in the coarse-grained alluvial sediments. South of the unnamed tributary, the upper 3 to 10 ft of the alluvium consists predominantly of very fine to fine sand, coarsening upward to fine to medium sand. North of the unnamed tributary, the upper facies is generally fine grained, predominantly very fine sand and silt. The upper facies also contains many finely disseminated organic fragments. The entire 10- to 12-ft alluvial section can be seen in two locations in the western bank of the river, south of the junction with the unnamed tributary. In both outcrops, a layer of ancient vegetational debris, including trunks of large trees, is present at the base of the alluvium. At one outcrop, approximately 1 ft of Presumpscot Forma-tion is exposed above river level below the alluvial section.

During installation of the manual-auger holes in the flood plain north of the unnamed tributary, ground water was encountered only after the upper fine-grained alluvial facies was penetrated (at a depth of 4 to 5 ft). Within minutes after completion of each hole, water levels rose to ground surface, and water actually flowed out of several of the holes.

Hydraulic heads in the aquifer that are several feet above the river near Boiling Springs can be attrib-uted to converging flow lines as ground water flows vertically towards the river. A lower vertical than hori-zontal hydraulic conductivity also may cause elevated heads at depth, relative to heads in the river. Highest

18 Distribution of Trichloroethylene and Geologic Controls on Contaminant Pathways near the Royal River, McKin Superfund Site Area, Gray, Maine

Page 19: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

vertical hydraulic gradients and highest ground-water discharges at the river would be expected at the edge of the river (McBride and Pfannkuch, 1975), and gradi-ents would decrease across or along the river. Never-theless, the presence of TCE in samples from the center and along the eastern bank of the river indicates that ground water near the TCE plume upstream from the bend in the river discharges across the width of the river. The presence of TCE along the eastern bank downstream from the bend may indicate that some ground water passes beyond the river near the bend and discharges downstream. Concentrations of TCE exceeding 1,000 ppb by volume at several locations downstream from the bend and upstream from the rail-road trestle indicate the plume may parallel the river downstream from the sand boils and bend. The TCE that discharges downstream from the bend originates at greater depth in the aquifer system than water that discharges at the sand boils. Possible directions of ground-water flow near the river are shown as arrows in figure 5b.

Relatively low (less than 500 ppb by volume) TCE concentrations in samples collected downstream from the railroad trestle (fig. 6) indicate that most of the TCE inflow to the river ends at the trestle. The presence of TCE in vapor-diffusion samplers placed in river-bottom sediments downstream from the trestle may result from the introduction of river water that also contained TCE. A streamflow of about 27 ft3/s, which was measured when samplers were retrieved, would be expected to contain from 15 to 20 µg/L of TCE (John Sevee, written commun. 1998). A concentration of 15 to 20 µg/L in water might yield a concentration of 300 to 400 µg/L in vapor, assuming a multiplication factor of 20. TCE may have reached the samplers by diffu-sion, by the introduction of river water at the time samplers were installed, by natural flow of river water through bottom materials, or some combination of these factors. Extension of the TCE plume in ground water beyond the railroad trestle, however, is possible and cannot be excluded on the basis of available infor-mation.

Water that leaks upward from the aquifer along the river and flood plain may enter the coarse-grained, organic-rich sediments at the base of the alluvium, which in turn could be a major pathway for ground water near the river. The overlying fine-grained allu-vium may serve as a semi-confining layer for water in the fan materials and the gravel layer at the base of the alluvium. Boiling Springs may be the expression of a

zone of relatively high vertical hydraulic conductivity in the alluvium that was enhanced by the removal of fine-grained sediments by flowing ground water.

The absence of TCE in several samples from the center of the Royal River near Boiling Springs (samplers 24C to 28C) is difficult to explain. Fine-grained alluvium that limits vertical flow of ground water may be present in a pooled area of the river near these samplers. Other possible explanations include circulation of river water through bottom sediments in this area, and very slow equilibration of water in the sediments with water in the aquifer after placement of the samplers. The absence of TCE in vapor-diffusion samples from sediments along the unnamed tributary reinforces the concept that the unnamed tributary does not receive water by upward leakage from the aquifers at depth.

SUMMARY AND CONCLUSIONS

Vapor-diffusion samplers were installed in September 1997 and retrieved and analyzed 2 weeks later in October 1997 to determine the lateral extent and distribution of TCE concentrations in the ground-water-discharge area near the McKin Superfund Site in Gray, Maine. Vapor-diffusion samples were analyzed on site using a portable gas chromatograph. Analyses of vapor in the samples confirmed the presence of a plume about 800 ft wide entering the Royal River. The highest observed concentration of TCE in vapor was 30,400 ppb by volume in an area of sand boils on the western bank of the river. Previous studies showed that much of the TCE load in the river originated in the area of the sand boils. In general, highest concentrations were observed on the side of the river nearest the source, but TCE also was detected at some locations in the center and eastern bank of the river.

A review of geologic conditions near the river indicates that the TCE plume discharges to the river where fine-grained sediments of the Presumpscot Formation are absent and where coarse-grained facies of buried glaciomarine fan deposits provide preferred pathways for ground-water flow. The plume probably passes under and beyond the river in the area of Boiling Springs and along the river downstream from the sand boils. A coarse-grained, organic-rich layer at the base of alluvial sediments along the river may be confined by overlying fine-grained alluvial sediments and may provide a conduit for ground water leaking upward from buried glaciomarine fan deposits. TCE vapors in

SUMMARY AND CONCLUSIONS 19

Page 20: DISTRIBUTION OF TRICHLOROETHYLENE AND GEOLOGIC … · 2003-03-27 · Mean annual flow of the Royal River at USGS streamflow-gaging station 01060000 at Yarmouth, Maine, for the period

y-,

s

a-

-c- er,

c-

.-

samples downstream from both the railroad trestle and the likely extent of the plume can be attributed to the introduction of river water that contained TCE when samplers were installed, diffusion of TCE from the river into bottom sediments, local advective exchanges of water between the river and bottom sediments, or a combination of these factors. The possibility that the plume of TCE in ground water parallels the river down-stream from the trestle, however, cannot be excluded on the basis of available hydrologic and water-quality information.

REFERENCES

Bloom, A.L., 1960, Late Pleistocene changes of sea level in southwestern Maine: Augusta, Maine, Maine Geologi-cal Survey, 143 p.

———1963, Late-Pleistocene fluctuations of sea level in southwestern Maine: American Journal of Science, v. 261, p. 862-879.

Creasy, J.W., and Robinson, A.C., 1997, Bedrock geology of the Gray 7.5-minute quadrangle, Cumberland County, Maine: Maine Geological Survey Open-File Map 97-3, scale 1:24,000.

McBride, M.S., and Pfannkuch, H.O., 1975, The distribution of seepage within lakebeds: U.S. Geological Survey, Journal of Research, v. 3, no. 5, p. 505-512.

Nielsen, J.P., Lippert, R.G., and Caldwell, J.M. 1997, Water resources data, Maine, water year 1996: U.S. Geologi-cal Survey Water-Data Report ME-96-1, 173 p.

Sevee & Maher Engineers, Inc., 1989, Hydrogeologic inves-tigation, DEP-8 study area remediation and pilot-scale treatability study—consultant report prepared for McKin Superfund Site Trust: Cumberland Center, Maine, Sevee & Maher Engineers, Inc., and Environ-mental Engineering & Remediation, Inc.

_______ 1993, Technical analysis of the ability of ground-water extraction and treatment to restore the aquifer in the area east of Mayall Road, McKin Superfund Site, Gray, Maine: Cumberland Center, Maine, 52 p., appen-dixes.

______ 1998, Subsurface investigation report, McKin Superfund Site/Gray Depot area, Gray, Maine: Cum-berland Center, Maine, 19 p., 6 appendixes.

______ 1999, Data transmitted and site conceptual model description, McKin Superfund Site: Cumberland Cen-ter, Maine, variously paged, appendixes.

Tetra Tech NUS, Inc., 1998, Draft technical memorandum, revision 1, Remedial alternatives screening, Royal River discharge zone, McKin Superfund Site, Gray, Maine: Wilmington, Massachusetts, 45 p., 10 appen-dixes.

U.S. Environmental Protection Agency, 1992, Super-fund—Progress at National Priority List Sites, Maine1992 update: U.S. Environmental Protection AgencyPublication 9200.5-720B, 23 p.

———1998, EPA Region 1 ambient air grab sample analsis for volatile organic compounds: Lexington, Mass.U.S. Environmental Protection Agency, March 1998,6 p.

Vroblesky, D.A., and Hyde, W.T., 1997, Diffusion sampleras an inexpensive approach to monitoring VOCs in ground water: Ground Water Monitoring and Remedition, v. 17, no. 3, p. 177-184.

Vroblesky, D.A., Rhodes, L.C., Robertson, J.F., and Harrigan, J.A., 1996, Locating VOC contamination in a fratured-rock aquifer at the ground-water/surface-waterinterface using passive vapor collectors: Ground Watv. 34, no. 2, p. 223-230.

Vroblesky, D.A., and Robertson, J.F., 1996, Temporal changes in VOC discharge to surface water from a fratured rock aquifer during well installation and opera-tion, Greenville, South Carolina: Ground Water Monitoring and Remediation, v. 16, no. 3, p. 196-201

Weddle, T.K., 1997, Surficial geology of the Gray quadrangle: Maine Geological Survey Open-File Map 97-58,scale 1:24,000.

20 Distribution of Trichloroethylene and Geologic Controls on Contaminant Pathways near the Royal River, McKin Superfund Site Area, Gray, Maine