10
SIGMA constantly endeavors to improve products so that information in this catalog is subject to change without notice. Distributed by

Distributed by - ascensor Sigmaascensorsigma.com/catalogos/escalator.pdfDistributed by. After serving for ... Skirt guard Triple reinforced structure ... Skirt Guard Safety Device

  • Upload
    dinhdat

  • View
    218

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Distributed by - ascensor Sigmaascensorsigma.com/catalogos/escalator.pdfDistributed by. After serving for ... Skirt guard Triple reinforced structure ... Skirt Guard Safety Device

SIGMA constantly endeavors to improve products so that information in this catalog is subject to change without notice.

Distributed by

Page 2: Distributed by - ascensor Sigmaascensorsigma.com/catalogos/escalator.pdfDistributed by. After serving for ... Skirt guard Triple reinforced structure ... Skirt Guard Safety Device

After serving for over 30 years as the feet of global villagers,the former LG Elevators and Escalators of LG Industrial Systems Co.,Ltd.lives on with the birth of Sigma Elevator Company.

On the basis of time-tested and valuable expertise, our everlasting ardor for customer satisfaction under the banner of "New Technology," Perfect Quality," and "Best Services" will be sustained by SIGMA Elevator in the new millenium.

BBirth of " SIGMA Elevator "

Page 3: Distributed by - ascensor Sigmaascensorsigma.com/catalogos/escalator.pdfDistributed by. After serving for ... Skirt guard Triple reinforced structure ... Skirt Guard Safety Device

We are proud to introduce a new generation of escalators with our SCE series.Sigma Commercial Escalators are well suited for today’s urban structures. New technologicaladvancements have been applied to make the escalators the world-best in design and safety.New technology and aero-dynamic design make Sigma escalators appealing while improvedstrength and safety features offer security to users.Manufactured by the Changwon factory in Korea, Sigma escalators will continue to meetstringent customer requirements with higher goals than expected.With certificates to meet various standards around the world, we offer the best quality andsafety with Sigma escalators.

Overview of the Changwon factory, Korea

Page 4: Distributed by - ascensor Sigmaascensorsigma.com/catalogos/escalator.pdfDistributed by. After serving for ... Skirt guard Triple reinforced structure ... Skirt Guard Safety Device

Micom ControllerFault Code Display (LED)Traffic Information Display InterfaceDouble Coil BrakeLower Starting Shock (Y-¡ start)Remote Monitoring Interface

W orm HelicalM a chine

High EfficiencyLow NoiseReliable Brake SystemSafety Provisions

CompactVertical worm helical machineCompact designEfficient maintenance

New TechnologyBetter world with Sigma Escalators...

Artistic design, best safety and best ride. N ew concept of engineering resulting safe

and low noise SIGMA Escalator .A different escalator...

Maintenance Ro o mClear area expanded (EN Code applied)

3 | 4SIGMA Escalator

RobustStrength with the comfort andlow noise

Design Artistic design with smoothand natural lines

SafetyElimination of the source ofsafety hazards

Page 5: Distributed by - ascensor Sigmaascensorsigma.com/catalogos/escalator.pdfDistributed by. After serving for ... Skirt guard Triple reinforced structure ... Skirt Guard Safety Device

Aero-Dynamic Design

Silver(Option)BlackBlue

Clear Green(Option) Bronze(Option)

Aluminium Aluminium(Option) Stainless steel(Option)

Direction indicator Various colors forhandrails

Ebony(Black) ES-01Scarlet ES-10(Option)Sapphire ES-27(Option)Crimson ES-20(Option)Mid Grey ES-12(Option)Emerald ES-29(Option)

Unique SIGMA escalator design and variousdesign options make possible assimilation withbuilding aesthetics.

Simple and yet, modern design of handrail inlet coupled with slim deck line lampraised escalator design to the next level while maintaining safety

Above colors may differ from the actual color due to printing ( Actual colors may differ)

Glass panel

3 Types of Entry Box

Floor

Better design for a better world...

5 | 6SIGMA Escalator

Page 6: Distributed by - ascensor Sigmaascensorsigma.com/catalogos/escalator.pdfDistributed by. After serving for ... Skirt guard Triple reinforced structure ... Skirt Guard Safety Device

Robust

One-body stepOne-body steps from step die casting machine

Skirt guardTriple reinforced

structure

Demarcation cleatReinforced to prevent breakage

Aluminium moldStrong aluminium mold

Perfection of strength and sturdiness...

From angle truss to high torsion resisting 4 angled pipe truss...

One-body Step escalator die casting machineHardness enhanced to prevent fractures

Existing escalator frame

Existing escalator truss structure

SIGMA Escalator7 | 8SIGMA Escalator

Page 7: Distributed by - ascensor Sigmaascensorsigma.com/catalogos/escalator.pdfDistributed by. After serving for ... Skirt guard Triple reinforced structure ... Skirt Guard Safety Device

Safety measures surpass EN115 of Europe!User safety comes first in SIGMA escalators

Controller Lifting Device Comb Plate Switch Safety Guard at upper andlower machine rooms

Step Safety Switch Lock/Tag-out Switch Entry Switch Skirt Guard Safety Device Driving Chain Safety Device

Step Roller Safety Device Step Chain Safety Device Emergency Stop Device /Operation Monitoring LED

Expanded Maintenance Area

Gap between step and skirt guardSurpassed EN Code requirements

Entry boxHandrail inlet engineered throughmock emergency tests

HandrailEngineered to prevent fingers gettingcaught between frame and handrail

Safety is the foundation of design...

9|10SIGMA Escalator

Page 8: Distributed by - ascensor Sigmaascensorsigma.com/catalogos/escalator.pdfDistributed by. After serving for ... Skirt guard Triple reinforced structure ... Skirt Guard Safety Device

Structure and Safety Device

New Generation Escalator

Self-diagnostic functions with remotecommunication

Engineered through field know-how

Advanced safety system with robust design

Emergency Stop Device & OperationMonitoring(LED)In an emergency, stops the escalator immediately if pressed.Operation Monitoring LED

Flickering : requires removal of foreign material and re-start bysite managersOn : requires repair by maintenance personnel

Step Safety SwitchStops escalator if steps areoperating in abnormal manner dueto fractured step

Step Chain Safety DeviceStops escalator if the step chainbreaks or becomes loose.

Skirt Guard Safety DeviceStops escalator if objects are caughtbetween step and skirt

Controller Lifting DeviceFor easy removal of controllerduring maintenance

Driving Chain SafetyDeviceStops escalator if the driving chainbreaks or excessively loosened

Comb Plate Safety SwitchStops escalator if objects are caughtbetween comb plate and step treads.

Entry SwitchStops escalator if hand or object ispulled into the handrail inlet

Step Roller Safety DeviceStops eacalator if steps are operating in abnormalmanner due to reasons such as foreign matters beingcaught between steps.

Non-reversing Safety DeviceStops escalator if its direction of travel is reversed

Additional option safety devices

Overspeed Detector Stops escalator if operating above normal speedAuxiliary BrakeStops escalator if the driving chain breaks or over-speeds

Brake Lining Wear Safety DeviceStops escalator if the lining of main brake is worn abnormally

Handrail Speed Detector Stops escalator if handrail speed is below norm due to handrail breakage or elongations

Handrail Stop Device Stops escalator if handrail breaks or stops

Handrail Static Preventor Prevents static electricity with handrail rollers installed blocking static electricity

HANDRAIL

DECK

GLASS PANEL

DRIVING UNIT

STEP

COMB

CONTROLLER

TRUSS

RAIL

HANDRAIL DRIVING PULLEY

SKIRT GUARD

EMERGENCY STOP DEVICE

FLOOR

HANDRAIL ENTRY BOX

11|12SIGMA Escalator

Page 9: Distributed by - ascensor Sigmaascensorsigma.com/catalogos/escalator.pdfDistributed by. After serving for ... Skirt guard Triple reinforced structure ... Skirt Guard Safety Device

K

600

FL. FL.

FL.FL.

Layout & Dimensions

Specification

From material to manufacturing engineering, researchworks are unified and focused to enhance our escalatortechnology.

13|14SIGMA Escalator

FINISHED FLOOR

WORKING POINT WORKING POINT

L=L1+A+B+100

MIN.M

H(RI

SE)

JM

IN.K

D

800

J

H(RI

SE)

K

FL.

FL. FL.

L1=(30 =1.732 H,35 =1.428 H)

RAILING

(BY OTHERS)

(BY OTHERS)

EXTERIOR PANEL

W.PPOWER SUPPLY

F

W.P

R1

R2

W2W1

W3

MIN.PIT WIDTH

MIN

.PIT

DEP

TH

FINISHED FLOOR

W

200

G

E

GUARD AT CEILING

MIN

.230

0

C

50

600

AB50

(BY OTHERS)

FINISHED FLOOR(BY OTHERS)

T

Support Loads

Through product development focused on safety and comfort, traveling up ordown in buildings or department stores is safe, quick and convenient.

Angle ofinclination

SCE 30

SCE 35

SCE 30

SCE 35

30

35

30

35

2

2

1.5

1.5

2050~6000

2050~6000

2050~6500

2050~6500

R1(kg)

0.64H + 2500

0.52H + 2800

0.64H + 2100

0.52H + 2600

R2(kg)

0.64H + 1900

0.52H + 2300

0.64H + 1500

0.52H + 2100

R1(kg)

0.80H + 3100

0.67H + 3400

0.76H + 2800

0.67H + 3000

R2(kg)

0.80H + 2500

0.67H + 2800

0.76H + 2400

0.67H + 2300

Type

LoadModelNo.of Flat Step Rise

800 Type 1200 Type

270 50

140

140

320

(Concrete Support Structure)

250250

140140

5050 MIN.300MIN.300

MIN.200MIN.200

140

140

(unit : mm)Frame Support

FINISHED FLOOR(BY OTHERS)

BASE PLATE

BASE PLATE

BASE PLATE

STEEL BAR(BY OTHERS)

SUPPORT PLATE(BY OTHERS)

BASE PLATE

SUPPORT PLATE(BY OTHERS)

STEEL BAR(BY OTHERS)

FINISHED FLOOR(BY OTHERS)

FINISHED FLOOR(BY OTHERS)

RIB(BY OTHERS)RIB(BY OTHERS)

FINISHED FLOOR(BY OTHERS)

320

140

140

27050

(Steel Beam Support Structure)

LOWER END UPPER END

LOWER END UPPER END

When H is above 6,000mm, consult Sigma for further details.When L is over 16,000mm, an intermediate support is required.For no intermediate support and when L is over 16,000mm,

consult Sigma for further detailsGiven dimensions may change without advance notice

ModelType

Dimension

2050 ~ 6500

2050 ~ 6000

2050 ~ 6000

2050 ~ 6000

800 1200

2215 2215

2915 2415

2290 2290

2990 2490

1945

2145

2020

2220

1665

1865

1740

1940

1395

1595

1470

1670

730

730

730

730

30

30

35

35

950

950

950

950

1020

1020

1020

1020

1100

1100

1100

1100

2300

2300

2000

2000

1.5

2

1.5

2

Rise(H)No.ofFlatStep

SCE30

SCE30

SCE35

SCE35

unit : mmDimensionsA

B C D E

E: Incase of EN115 compliance, E is 800mm

F G J K M

ModelType

Dimension

2050 ~ 6000

Rise(H)

SCE30 & SCE 35

Step Width W W1 W2 W3

800

604

1200

1004

800

609

1200

1009

800

820

1200

1220

800

1150

1200

1550

800

1250

1200

1650

Page 10: Distributed by - ascensor Sigmaascensorsigma.com/catalogos/escalator.pdfDistributed by. After serving for ... Skirt guard Triple reinforced structure ... Skirt Guard Safety Device

Standard SpecificationsPart Material

Balustrade

Floor

Step

Handrail

Handrail Frame

Deck Cover

Panel

Comb

Comb Plate

Floor

Cleats and Riser

Demarcation Line

Note) For other optional specifications, please contact Sigma Elevator Company

Composite rubber

Aluminum

Stainless Steel with Hairline finish

Tempered glass

Aluminum

Aluminum

Aluminum

Aluminum with gray color paint

Yellow Synthetic resin on three sides

800Type

800mm

604mm

4500 Passengers/hour

1200Type

1200mm

1004mm

9000 Passengers/hour

30m/min

30 / 35

AC 60/50 Hz, 380~440V

Three Phase Induction Motor

Reversible System

Construction

Type

Nominal Width

Tread Width

Capacity

Speed

Angle of Inclination

Power Source

Driving Motor

Operation System

Standard

EN 115

Motor TypeModel 5.5kW 7.5kW 9.5kW

SCE30

SCE35

SCE30

SCE35

800

1200

800

1200

800

1200

800

1200

Lead-in Wires( ) 3.5

MCCB CAPACITY OF BUILDING(A)

5.5

30

5.5

4020400V

Power Source 400V

Power Source

5.8m

4.5m

5.8m

4.5m

4.5m

3.4m

4.5m

3.4m

6.5m

6.5m

6.0m

6.0m

6.0m

4.8m

6.0m

4.9m

6.0m

6.0m

15|16SIGMA Escalator

All dimensions are minimum(unit : mm)Dimensions of < > is in case of transferring escalatorwithout BalustradeFor detailed information, please consult Sigma

Well holes on the center line of escalator (carrying force min.6,500kg)

Well holes on the center line of escalator (carrying force min.5,500kg)

Side Entrance Floor / Ceiling Entrance

Well Hole Entrance Dimensions

1950

3000

<23

00>

4800<4600> 1950

No.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Works by Others

Cutting and patching of any holes needed to install the escalator

Providing bases and supports for installation

Providing clear access to well ways.

Providing a pit and moisture proofing at the lower end of escalator

(If there are rooms occupied below this level, the pit must be of fire-resistant construction)

Finishing the floor and ceiling around the escalator after installation

Installation of safety railings around the escalator

Installation of exterior truss panels or other external decoration

Installation of delta guard at all intersections either between escalators

or between escalator and ceiling

Installation of barriers and safety railings in the space between paired escalators

Finishing ceilig edges, etc., around escalator wells

Installation of safety net in the ceiling space between paired escalators, if required

Providing clear access for equipment and all necessary building renovation work for existing

buildings where escalators are to be installed

Providing proper finish works around escalators for existing building installations

Proper safety protection, within 500mm from the handrail out side and 2,100mm from flooring,

against any columns or open ceilings, etc.

Any connection works for interfaces with building s fire emergency protocols

No.

16

17

18

19

20

21

22

Works by Others

Installation of power line wiring to the upper escalator machine room

Installation of maintenance line wiring to upper escalator machine room

Installation of earth(ground) lines to upper escalator machine room

Installation of power supply and switches for escalator lighting

Installation of building equipment such as sprinkler system, public address systems and signs

Installation of power supply and switches for escalator lighting in lower ends

Installation of 4 non-Voltage lines (2 upper, 2 lower) for fire shutters

Building Construction

Electrical Wiring