    Leica DISTOA2

    The original laser distance meter

  • 8/9/2019 DistoA2 Manual

    2/9

  • 8/9/2019 DistoA2 Manual

    3/9

  • 8/9/2019 DistoA2 Manual

    4/9

    1 OverviewLeica DISTO A2 1.0.0 gb

    d

    GB

    F

    I

    E

    P

    NL

    DK

    S

    N

    FIN

    J

    CN

    ROK

    PL

    H

    RUS

    CZ

    User ManualEnglish

    Congratulations on your purchase of a Leica DISTO.

    The safety instructions can befound in a separate booklet, whichaccompanies this user manual.The safety instructions along with

    the user manual should be read carefully before initialoperation.

    Overview

    KeyboardSee drawing{A}:1 ON/DIST (ON/MEASUREMENT) -key2 PLUS [+]-key3 AREA/VOLUME -key4 REFERENCE -key5 CLEAR/OFF-key6 UNITS/ (UNITS/ILLUMINATION) -key7 MINUS [-] -key

    DisplaySee drawing {B}1 Laser "ON"2 Reference (front/rear)3 Area/volume4 Battery symbol

    5 Main targets6 Units with exponents (2/3)7 Second row (e.g. intermediate values)

    Start up

    Inserting / Replacing BatteriesRemove the battery cover, insert the batterycorrectly. Close the battery compartment. Replacethe battery when this symbol constantly blinksin the display. Only use alkaline batteries.

    Batteries should be removed due to danger ofcorrosion, if the device will not be used for a longtime.

    Selecting Units

    Possible units:

    Press this key until the desired unit isdisplayed.

    Distance Area Volume

    0.000 m 0.000 m 0.000 m

    0.00 ft 0.00 ft 0.00 ft

    0' 0'' 1/160.00 ft 0.00 ft

    0.0 in 0.00 ft 0.00 ft

  • 8/9/2019 DistoA2 Manual

    5/9

    2Operation Leica DISTO A2 1.0.0 gb

    d

    GB

    F

    I

    E

    P

    NL

    DK

    S

    N

    FIN

    J

    CN

    ROK

    PL

    H

    RUS

    CZ

    Operation

    Switching on/off

    The battery symbol is displayed until a key is pressed.

    The device also switches off automatically after threemintutes of inactivity i.e. no key is pressed withinthat interval.

    CLEAR-Key

    Within a function (area, volume, etc.) single measure-ments can be deleted step by step and re-measured.

    Illumination

    Reference SettingDefault reference setting is from the rear of the

    instrument.

    After one measurement, the reference returns auto-matically to the default setting (rear reference). Seedrawing {C}.

    Measuring

    Single Distance Measurement

    The result is displayed immediately.

    Continuous MeasurementThis functions enables distances to be staked out.See drawing {D}.

    The last measured value is displayed in the summary

    row.

    Functions

    Addition / SubtractionDistance Measurement.

    Repeat this procedure for as many times as required.The result is always displayed in the summary row,the previous value is displayed in the second row.

    Device and laser are switched on.

    Holding down this key switches the device off.

    The last action is cancelled

    Switches the illumination on or off.

    The next measurement references the front ofthe instrument.

    Press to activate the laser. Press again totrigger the distance measurement.

    Press and hold key down until a "beep" soundis.heard.Press key again briefly: continuous measure-ment is stopped.

    The next measurement is added to theprevious one.The next measurement is subtracted from theprevious one.

    The last operation is cancelled.

  • 8/9/2019 DistoA2 Manual

    6/9

    3 FunctionsLeica DISTO A2 1.0.0 gb

    d

    GB

    F

    I

    E

    P

    NL

    DK

    S

    N

    FIN

    J

    CN

    ROK

    PL

    H

    RUS

    CZ

    Area

    The result is displayed in the main line.

    Volume

    The area of the two values measured is displayed inthe main line.

    The resulting volume is displayed in the main line.

    Staking out of constant distancesConstant distances can be entered for staking outpurposes. The DISTO's display shows the to be stakedout distance as well as multiples of the distance. Assoon as the defined stake out distance is reached theDISTO beeps.

    Inputting a stake out distance: Press and hold the, key, the auxiliary line will blink with crosslines.Change the value in the main line with andkeys until the desired staking out distance isdisplayed. Holding the and down will speedup the adjustment.

    By pressing the key the staking out distance ormultiples of it are displayed in the auxiliary line; the

    laser measuring starts. In the main line the distancebetween the staking out point (in the auxiliary line)and the DISTO (rear measuring reference) isdisplayed.

    If the DISTO is moved along the staking out line, thedisplayed distance is reduced. At a distance of 0.1 mto the next staking out point the DISTO starts tobeep. As soon as the staking out point is reached, the

    beep changes and the auxiliary line starts to blink.Repeat this procedure as often as needed.

    The function is stopped by pushing the key.

    Press this key once. This symbol isdisplayed.Press key and take the first measurement (e.g.length)Press key again and take the second measure-

    ment (e.g. width)

    Press this key twice.This symbol isdisplayed.Press key and take the first measurement (e.g.length)Press key again and take the second measure-ment (e.g. width)

    Press the key to take the third measurement(e.g. height). The value is displayed in thesecond line.

  • 8/9/2019 DistoA2 Manual

    7/9

    4Appendix Leica DISTO A2 1.0.0 gb

    d

    GB

    F

    I

    E

    P

    NL

    DK

    S

    N

    FIN

    J

    CN

    ROK

    PL

    H

    RUS

    CZ

    Appendix

    Display NoticesAll display notices are indicated by "InFo" or "Error".The following errors can be corrected.

    Technical Specifications

    * in favourable conditions (optimal target surface, roomtemperature) up to 12 m. In unfavourable conditions, such asintensive sunshine, very weakly reflecting target surface orlarge temperature fluctuations, measuring accuracy maydeteriorate to approx. 0.25 mm/m for distances above12 m.

    InFo Cause Correction252 Temperature too

    highLet device cool down.

    253 Temperature too low Warm device up255 Received signal too

    weak, time for ameasurement toolong.

    Use a target plate

    256 Received signal toostrong

    Use a target plate(gray side)

    257 Faulty measurement,too much back-ground light

    Use a target plate(brown side)

    Error Cause CorrectionHardware error If this message

    remains displayedafter switching thedevice off and onseveral times, pleasecontact our dealer-ship.

    Range (for extendeddistances, use a targetplate)

    0,05 m to 60 m(0.2 ft to 197 ft)

    Measuring accuracy (2 ) typically: 1.5 mm(0.06 inch)*

    Smallest unit displayed 1 mmLaser class II

    Laser type 635 nm, < 1 mW

    Automaticpower off after 180 s

    Display illumination

    Continuous measure-ment

    Addition / subtraction Battery life,9 V compound battery up to 5000 measurements

    Dimensions and weight 124x54x35 mm, 155 g

    Temperature range:Storage

    Operation

    -25C to +70C(-13F to +158F)

    -0C to+40C(+32F to + 104F)

  • 8/9/2019 DistoA2 Manual

    8/9

    5 AppendixLeica DISTO A2 1.0.0 gb

    d

    GB

    F

    I

    E

    P

    NL

    DK

    S

    N

    FIN

    J

    CN

    ROK

    PL

    H

    RUS

    CZ

    Measuring Conditions

    RangeRange is limited to 60 m.At night, at dusk or if the targets are shaded, therange increases without using a target plate. Whenambient light is intense and the targets have poorreflecting properties, use a target plate!

    Target SurfacesMeasuring errors can occur when measurements aremade targetting colourless liquids (e.g. water), clearglass, polystyrene or similar semi-translucentsurfaces, as well as from highly reflecting targets thatdeflect the laser.

    CareClean with a soft, damp cloth. Never immerse the unitin water. Never use aggressive cleaning agents orsolvents.

    WarrantyThe Leica DISTO A2 comes with a two year warrantyfrom Leica Geosystems.More detailed information can be found at:www.disto.com

    All right reserved for changes (drawings, descriptionsand technical specifications).

  • 8/9/2019 DistoA2 Manual

    9/9

    Leica Geosystems AGCH-9435 Heerbrugg(Switzerland)www.disto.com

    Leica Geosystems AG, Heerbrugg, Switzerland has been certified as being equippedwith a quality system which meets the International Standards of QualityManagement and Quality Systems (ISO standard 9001) and EnvironmentalManagement Systems (ISO standard 14001).

    Total Quality Management - Our commitment to total customer satisfaction. Ask yourlocal Leica Geosystems agent for more information about our TQM program.

    Printed in Switzerland - Copyright Leica Geosystems AG, Heerbrugg,Switzerland 2006Translation of original text (752828a-1.0.0)

    Pat. No.: WO 9427164, WO 9818019, WO 0244754, WO 0216964,

    US 5949531, EP 1195617