3
SIL AND NON-SIL DISPLAYS FOR RAILWAY APPLICATIONS Displays

Displays - Selectron · All displays in SIL and non-SIL design Safety-oriented display and safety-oriented input Less wiring means reduction of errors thanks to less cables, contacts,

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Displays - Selectron · All displays in SIL and non-SIL design Safety-oriented display and safety-oriented input Less wiring means reduction of errors thanks to less cables, contacts,

SIL AND NON-SIL DISPLAYS FOR RAILWAY APPLICATIONS

Displays

Page 2: Displays - Selectron · All displays in SIL and non-SIL design Safety-oriented display and safety-oriented input Less wiring means reduction of errors thanks to less cables, contacts,

2 3

c

E

098765432

F1

F2

F3

F4

F5

F6

1

S E L E C T R O NS Y S T E M SD I S P L AY S

SAFETY-ORIENTED DISPLAY (SIL 2) AND OPERATION

FEATURES STANDARD MODEL

Interface:

2 x Ethernet 10/100 Mbit/s2 x USB 2.02 x Analog/PAL/NTSC CCTV inputs 1 x Audio input1 x Audio output

Display Types:Touch: 10.4", @ 1024x768, 1000 cd/m2

Touch: 12.1", @ 1024x768, 1300 cd/m2

Touch + UIC 612: 10.4" @ 1024x768, 1000 cd/m2

Power Supply: 24 ... 110 VDC

Processor:Quad Core 32/64-bit ARM®-based processor, 1.3 GHz

Memory:

2GB DDR3 @ 1600MBit/s, 64Bits4 GB SLC NAND16GB eMMC MLC NAND1 Mbit FRAM

SIL Certification:Available for all models with safety-orientedcommunication up to SIL 2 according to EN 50159 (category 2)

H.264 Video Acceleration:

1 x 2048x1536 @ 25fps @ 20% CPU load4 x 2048x1536 @ 25fps @50% CPU load8 x 704x576 @ 25fps @25% CPU load

Temperature Range:Storage: –40 °C ... +85 °COperating: –30 °C ... +70 °C10 W internal heating when below –30°C

Windows Tooling: Maestro Designer®

Software Update via:EthernetUSB

Standards: EN 50155, EN 61373, EN 45545 HL3

Protection Class: IP65

Power Consumption:Screen size dependent:Typical: 7 W – 18 WMaximum: 35 W

SUPERB READABILITY AND INTUITIVE DEVELOPMENT ENVIRONMENT REPLACES EXPENSIVE SWITCHES, BUTTONS AND ANALOG GAUGES

Replaces expensive control elements with SIL functions, like tachometer, displayed on the touchscreen

All displays in SIL and non-SIL design

Safety-oriented display and safety-oriented input

Less wiring means reduction of errors thanks to less cables, contacts, and control elements

Touch displays in 10.4" and12.1"

UIC 612 10.4" displays

Ethernet as vehicle bus interfaces

Communication of SIL and non-SIL telegrams over one network

Safety-oriented communication (SIL 2) according to EN 50159

Safety oriented video screen (CCTV)

Savings on train certification efforts thanks to automatic documentation management

Detailed train diagnosis

Effortless troubleshooting

One programming tool Maestro Designer® for SIL and non-SIL application

Application programming includes widget technology

Flexible modifications and extension of functionality

Further widget libraries

– Alarm Widget – ETCS

– Topology Widget

DISPLAY SIZES

DISPLAY SIZE

SAFETY-ORIENTED AND NON-SAFETY-ORIENTED FUNCTIONS WITHIN ONE APPLICATION

ALL MODELS ARE AVAILABLE IN SIL AND NON-SIL "SAVINGS ON WIRING, ENGINEERING, AND THECERTIFICATION PROCESS"

Touch: 10.4", 12.1"

UIC 612: 10.4"

More efficient engineering processes via our tailored-application programming software Maestro Designer® and comprehensive diagnosis tool Concerto®

SIL Touch Display

TECHNICAL DATA

max. 3 max. 12

Touch Display

Touch Display and UIC 612 keys

SIL Touch Display and SIL UIC 612 keys

Page 3: Displays - Selectron · All displays in SIL and non-SIL design Safety-oriented display and safety-oriented input Less wiring means reduction of errors thanks to less cables, contacts,

This publication may be subject to alteration without prior notice. A printed copy of this document may not be the latest revision. Please contact your local Knorr-Bremse representative or check our website www.knorr-bremse.com for the latest update. The figurative mark „K” and the trademarks KNORR and KNORR-BREMSE are registered in the name of Knorr-Bremse AG. Copyright 2016 © Knorr-Bremse AG. All rights reservd. Including industrial property rights applications. Knorr-Bremse AG retains any power of disposal, such as for copying and transferring.Subject to technical changes and amendments to technical specification at any time

4393

0684

08

.2018

Selectron Systems AG

Bernstrasse 703250 LyssSwitzerland Tel: +41 32 387 61 61 Fax: +41 32 397 61 00

W W W . S E L E C T R O N . C H