Dispatch Circuit Break Yd

Embed Size (px)

DESCRIPTION

AIRBUS

Citation preview

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent. Dispatch with a

    Circuit Breaker tripped

    Yannick DUMOLLARDFlight Operations

    A380 MMEL

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Aircraft dispatch

    Impact on aircraft systems

    ELEC C/B TRIPPED

    Conclusion

    1

    2

    3

    4

    Contents

    Dispatch with a Circuit Breaker tripped

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Aircraft dispatch

    Impact on aircraft systems

    ELEC C/B TRIPPED

    Conclusion

    1

    2

    3

    4

    Contents

    Dispatch with a Circuit Breaker tripped

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 4

    ELEC C/B TRIPPED

    What is a C/B?

    C/B (Circuit Breaker) represents following devices

    Conventional circuit breaker

    Remote Control Circuit Breaker (RCCB)

    RCCB-C (Conventional RCCB)

    RCCB-P (Programmable RCCB)

    Solid State Power Control (SSPC)

    Devices are fitted in:

    Emergency Electrical Power Distribution Centre 2500VU

    (EEPDC)

    Primary Electrical Power Distribution Centre (PEPDC)

    Secondary Electrical Power Distribution Centre (SEPDC)

    APU control box (5000VE)

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Any tripped C/B is displayed in the cockpit by:

    The ELEC C/B TRIPPED alert with

    Its designation and FIN on the C/B SD page

    Dispatch with a Circuit Breaker trippedPage 5

    ELEC C/B TRIPPED

    FIN: Functional Item Number

    ELEC C/B TRIPPED

    C/B

    FUNCTIONAL DESIGNATION LOCATION FIN

    FWD CAX FAN | PDMI | 1HU

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 6

    ELEC C/B TRIPPED

    Any tripped C/B is monitored for Maintenance crew by:

    Maintenance message associated with affected

    system

    Protection Distribution Maintenance Interface (PDMI)

    that provides C/B status (open, open-tripped,)

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Aircraft dispatch

    Impact on aircraft systems

    ELEC C/B TRIPPED

    Conclusion

    1

    2

    3

    4

    Contents

    Dispatch with a Circuit Breaker tripped

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 8

    Impact on aircraft systems

    ELEC C/B TRIPPED

    Case 1 - Associated with a cockpit effect

    Another ECAM alert on affected systems

    Amber indication (on SD, Overhead panel,)

    Maintenance message (CMS Cockpit Items)

    Case 2 - Associated with maintenance message only

    CMS Pending Items

    CMS Minor Items

    Case 3 - Neither any cockpit nor maintenance message

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Aircraft dispatch

    Impact on aircraft systems

    ELEC C/B TRIPPED

    Conclusion

    1

    2

    3

    4

    Contents

    Dispatch with a Circuit Breaker tripped

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 10

    Aircraft dispatch

    MMEL Entry ELEC C/B TRIPPED

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 11

    Aircraft dispatch

    Extract MMEL Items/Preamble/ECAM & CMS paragraph

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 12

    Aircraft dispatch

    MMEL Entry ELEC C/B TRIPPED

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 13

    Aircraft dispatch

    SIL 24-084 Information for dispatch with ELEC C/B TRIPPED

    SIL provides table Tripped C/B & Possible effect

    List of all C/Bs

    Information on their affected systems

    Aircraft dispatch conditions

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 14

    Aircraft dispatch

    ELEC C/B TRIPPED

    C/B

    FUNCTIONAL DESIGNATION LOCATION FIN

    TAIL CONE VENT FAN | PDMI | 800HR

    ECAM alert

    C/B SD page

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 15

    Aircraft dispatch

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 16

    Aircraft dispatch

    ELEC C/B TRIPPED

    C/B

    FUNCTIONAL DESIGNATION LOCATION FIN

    TAIL CONE VENT FAN | PDMI | 800HR

    ECAM alert

    C/B SD page

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 17

    Aircraft dispatch

    ELEC C/B TRIPPED

    C/B

    FUNCTIONAL DESIGNATION LOCATION FIN

    FWD CAX FAN | PDMI | 1HU

    ECAM alert

    C/B SD page

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 18

    Aircraft dispatch

    ELEC C/B TRIPPED

    C/B

    FUNCTIONAL DESIGNATION LOCATION FIN

    MFD F/O NORM | PDMI | 801WK

    ECAM alert

    C/B SD page

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Aircraft dispatch

    Impact on aircraft systems

    ELEC C/B TRIPPED

    Conclusion

    1

    2

    3

    4

    Contents

    Dispatch with a Circuit Breaker tripped

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 20

    Conclusion

    MEL remains the reference to dispatch the aircraft

    SIL 24-084 issued May 2010

    Provides clear guidance for aircraft condition

    assessment

    Optimizes aircraft dispatch decision-making

    ELEC C/B TRIPPED

  • A

    IRB

    US

    S.A

    .S.

    All

    rights

    re

    se

    rve

    d. C

    onfide

    ntia

    l and p

    ropri

    eta

    ry d

    ocum

    ent.

    Dispatch with a Circuit Breaker trippedPage 21

    AIRBUS S.A.S. All rights reserved. Confidential and

    proprietary document.

    This document and all information contained herein is the sole

    property of AIRBUS S.A.S.. No intellectual property rights are

    granted by the delivery of this document or the disclosure of

    its content. This document shall not be reproduced or

    disclosed to a third party without the express written consent

    of AIRBUS S.A.S. This document and its content shall not be

    used for any purpose other than that for which it is supplied.

    The statements made herein do not constitute an offer. They

    are based on the mentioned assumptions and are expressed

    in good faith. Where the supporting grounds for these

    statements are not shown, AIRBUS S.A.S. will be pleased to

    explain the basis thereof.