06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type Description
0 without fasteners1 with 4 U-bolts M 12
for UNP 140 upright2 with 4 bolts M 16 x 40
Type Description
0 without fasteners1 with 4 U-bolts M 12
for UNP 140 upright2 with 4 bolts M 16 x 40
Disconnecting switch 15 kV, 1600 A
Disconnecting switch with vacuum quenching chamber 15 kV, 2000 A
1250
647 383963
ø30
51596
5
220
1140
A
ø16
ø19
563215 3187777
90325 615
110110
190
190
255
ø18
ø30
515
435 595
925
A
930
1290
7111
7112
Stroke length: 120 mm
Weight: Wt (kg) = 40
Note: Support 7511 o/w A = Axis of operating rod
Associated parts: Connecting clamp 7151 Operating rod 7311 / 7321
Drawing number: 564.00032, .00042, .00043
Special version: with fitted current transformer
Ordering information: for UNP 140 upright7111.1 Disconnecting switch 15 kV, 1600 A
Stroke length: 120 mm
Weight: Wt (kg) = 80
Note: Support 7511 o/w A = Axis of operating rod
Associated parts: Connecting clamp 7151 Operating rod 7311 / 7321
Drawing number: 564.00064, .00194, .00197
Ordering information: without fasteners7112.0 Disconnecting switch with vacuum quenching chamber 15 kV, 2000 A
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
1620
17050100 50
ø18ø18x68
760
100
230 530
A
7113 Disconnecting switch 15 kV
Stroke length: 200 mm
Weight: Wt (kg) = 31
Note: A = Axis of operating rod
Drawing number: 564.00034
Ordering information: 7113 Disconnecting switch 15 kV
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Disconnecting switch with earth contact 15 kV
1620
17050100 50
ø18ø18x68
760
100
585 530
A
7114
Stroke length: 200 mm
Weight: Wt (kg) = 36
Note: A = Axis of operating rod
Drawing number: 564.00037
Ordering information: 7114 Disconnecting switch with earth contact 15 kV
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type Description
0 without fasteners1 with fastening plate 7545
at sectioning point2 with 4 bolts M 12 x 40
Disconnecting switch 3,6 kV, 3400 A
80
125
ø14510
680
805
A
20
20
278
80
17
20 40
860
M 16x70
17
7141
Stroke length: 120 mm
Weight: Wt (kg) = 27
Note: Support 7541 o/w A = Axis of operating rod
Associated parts: Operating tube 7311 / 7321
Drawing number: 564.00026
Ordering information: without fasteners7141.0 Disconnecting switch 3,6 kV, 3400 A
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type Clamp range(mm2)
1 2 x 95 / 2 x 107 CW / 1 x ø 302 2 x 95 / 2 x 107 CW / 1 x ø 303 1 x 95 / 1 x 107 Fd / 1 x ø 30,
reducing bush ø 204 2 x ø 30, with reducing bush ø 20
Connecting clamp 1500 A, CW 150 / Rope 150 / ø 30
146.5
77
ø30
ø30
ø30
ø30
ø30
ø12ø12
ø12
ø12
ø12
Typ 1
Typ 2
Typ 4
Typ 3
7151
Note: Disconnecting switch 15 kV 7111 o/w Other clamp range on request.
Associated parts: Reducing bush ø 20 7153
Drawing number: 456.00001
Ordering information: Type 2 for 2 x 95/2 x 107 CW / 1 x ø 307151.2 Connecting clamp 1500 A, CW 150 / Rope 150 / ø 30
Material: G-CuSn5ZnPb / CuNi1, 5Si
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
166.5
87
ø30
ø30
ø30
ø15.9ø15.9
ø15.
9ø1
5.9
ø15.
9
Typ 1
Typ 2
Typ 3
ø30
605
ø20
2
7152
7153
Connecting clamp 1500 A, CW 150 / Rope 150 ø
Reducing bush ø 20
Type Clamprange(mm2)
1 2 x 150 CW, 1 x ø 302 2 x 150 CW, 1 x ø 303 1 x 150 CW, 1 x ø 30,
with reducing bush ø 20
Material: G-CuSn5ZnPb / CuNi1, 5Si
Note: Disconnecting switch 15 kV 7111 o/w Other clamp range on request.
Associated parts: Reducing bush ø 20 7153
Drawing number: 456.00002
Ordering information: Type 2 for 2 x 150 CW, 1 x ø 307151.2 Connecting clamp 1500 A, CW 150 / Rope 150
Associated parts: Connecting clamp 1500 A 7151/7152
Drawing number: 585.00070
Ordering information: 7153 Reducing bush ø 20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type Motor Voltage
15.110 VDC 110 V DC15.230 VAC 230 V AC25.110 VDC 110 V DC25.230 VAC 230 V AC
Unipolar indoor earthing isolator
M12
M12
45
570
355
ø15 15
200
200
420
7161
Weight: Wt (kg) = 35
Note: Unipolar indoor earthing isolator 15 kV.
Drawing number: 564.00035
Ordering information: 15 kV with 110 V DC Motor voltage7161.15.110 VDC Unipolar indoor earthing isolator
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
896
17050100 50
ø18ø18x68
760
100
230 530
A
7162 Earthing switch 15 kV
Stroke length: 200 mm
Weight: Wt (kg) = 33
Note: A = Axis of operating rod
Drawing number: 564.00038
Ordering information: 7162 Earthing switch 15 kV
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type Description
0 without fasteners1 with support 7652
at sectioning point2 with 3 bolts M 16 x 40
Type Key-bolt form
De TriangleHk SemicircleHm CrescentKr CrossRe RectangularSt StarTr TrapezoidVk SquareWa Shield
Type Language
D GermanF FrenchI Italian
Type Description
ZY.1 1 SEA lockZY.2 2 SEA lockZY.3 3 SEA lockZY.4 4 SEA lock
Manual switch operation with lock
130
18
28
01
03
5
10
41
76
180
14
R 350
ø30
7211
Stroke length: 120 mm
Note: Electric indicator 7213 Base plate 7243
Included: 1 bolt 7231 2 keys, order seperately 7232 1 switch indicator plate 7244
Drawing number: 566.00187, .00190, .00209, .00210
Ordering information: with support, crescent bolt, German7211.1.Hm.D Manual switch operation with lock
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
175
80
108
42
60
146
M4M4
7213.1
7213.2
7213 Electric indicator for manual switch operation
Type Description
1 without enclosure2 with enclosure
Note: Cable gland 6842
Fasteners: Supplied complete with M 4 bolts.
Drawing number: 566.00119, .00304
Ordering information: with enclosure7213.2 Electric indicator for manual switch operation
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type Description
0 without rod1 Rod without joint
Type Supply voltage
110 110 V DC230 230 V AC
Motor drive for switch MFL
216
620
303
292
65 130
169
280
1340
7221.0 7221.1
7221
Stroke length: 120 mm
Note: Supplied complete with handle for manual operation. Heating included. For conversion from manual to motor operation on the mast 7651
Fasteners: Supplied complete with 4 bolts M 16
Drawing number: 566.00188, .00189
Ordering information: without rod, 110 V DC7221.0.110 Motor drive for switch MFL
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
Type Supply voltage
110 110 V DC230 230 V AC
65130
280
329
280
200
261
660
7222.0
1735
7222.1
7222 Motor drive for switch MDR3
Type Description
0 without rod1 Rod without joint
Stroke length: 125 - 190 mm / 200 - 300 mm
Note: The lever have to be ordered for the stroke length of 200 - 300 mm. Supplied complete with handle for manual operation. Heating included. For conversion from manual to motor operation on the mast 7651
Fasteners: Supplied complete with 4 bolts M 16
Drawing number: 566.00272, .00273
Ordering information: without rod, 230 V AC7222.0.230 Motor drive for switch MDR3
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type Description
Re RectangularTr TrapezoidHk SemicircleHm CrescentSt StarWa ShieldKr CrossDe TriangleVk Square
Type Description
De TriangleHk SemicircleHm CrescentKr CrossRe RectangularSt StarTr TrapezoidVk SquareWa Shield
Bolt for manual switch operation with lock
Key for manual switch operation with lock
Re Tr Hk Hm
Wa Kr DeSt Vk
Re Tr Hk Hm
Wa St Kr De Vk
7231
7232
Drawing number: 585.00034
Ordering information: Trapezoid form7231.Tr Bolt for manual switch operation with lock
Drawing number: 585.00024-1
Ordering information: Trapezoid form7232.Tr Key for manual switch operation with lock
Material: CuSnPb
Material: CuSnPb
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Number plate for switch
Name plate for switch
Base plate
120
95
92
65
5
65
5,5
49/4
9110
80
ø30
7241
7242
7243
Note: When ordering, please state the text.
Drawing number: 581.00032
Ordering information: 7241 Number plate for switch
Note: When ordering, please state the text.
Associated parts: Base plate 7243
Ordering information: 7242 Name plate for switch
Drawing number: 566.00013
Ordering information: 7243 Base plate
Material: Al Background yellow, edge and number black
Material: Al Background red, script Al natural
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
96
96
40
4
0
40
20
7244
7245
Switch indicator plate for manual operation
Switch indicator plate for motor operation
Type Language Description
D German Ein, AusF French Enclenché, DéclenchéI Italian Inserito, Disinserito
Type Language Description
D.E German EinF.E French EnclenchéI.I Italian InseritoD.A German AusF.H French DéclenchéI.F Italian Disinserito
Material: Synthetic On: Background red, script white Off: Background white, script black
Associated parts: Manual switch operation 7211 o/w
Drawing number: 581.00044
Ordering information: German7244.D Switch indicator plate for manual operation
Material: Al Background Al, script black
Ordering information: French, Hors7245.F.H Switch indicator plate for motor operation
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type L(mm)
40 400050 500060 600070 700080 800090 9000
Type L(mm)
60 600070 700080 800090 9000
Operating rod, straight with tongue end / rod coupling
Operating rod, straight with rod coupling / rod coupling
L
ø30
200
200
20
0
L
ø30
14/30
50
7311
7312
Note: Disconnecting switch 7111 Disconnecting switch 7112 Disconnecting switch 7141
Drawing number: 561.00572, .01165
Ordering information: Length 7,0 m7311.70 Operating rod, straight with tongue end / rod coupling
Note: Disconnecting switch 7131
Drawing number: 561.00573, .01167
Ordering information: Length 8,0 m7312.80 Operating rod, straight with rod coupling / rod coupling
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type L(mm)
60 600070 700080 8000
Type L(mm)
60 600070 700080 8000
Operating rod, curved with tongue end / rod coupling
Operating rod, curved with rod coupling / rod coupling
50
300
14/30
390
200
L
ø30
300
390 ø30
200
L
7321
7322
Note: Disconnecting switch 7111 Disconnecting switch 7112 Disconnecting switch 7141
Drawing number: 561.00574
Ordering information: Length 6,0 m7321.60 Operating rod, curved with tongue end / rod coupling
Note: Disconnecting switch 7131
Drawing number: 561.00575
Ordering information: Length 8,0 m7322.80 Operating rod, curved with rod coupling / rod coupling
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Coupling for operating rod
30200
M 12
7331
Drawing number: 566.00012
Ordering information: 7331 Coupling for operating rod
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Tongue end fitting for rod ø 30 mm
150
ø23.6
ø30
ø16.
2
14
100
50
7341
Note: Disconnecting switch 7111 Disconnecting switch 7112 Disconnecting switch 7141
Drawing number: 561.00505-6
Ordering information: 7341 Tongue end fitting for rod ø 30 mm
Material: Fe stainless
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type Bolts
1 without2 with
Guide for switch operating rod ø 30 mm
220
301
1
46
175
23
174
0
ø30
7411
Drawing number: 561.00912, .01175
Ordering information: Without bolts7411.1 Guide for switch operating rod ø 30 mm
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Support for 1 disconnecting switch 15 kV on mast head
Support for 2 disconnecting switches 15 kV on mast head
80
110 1490
16
06
0
600 600
80
110
310
16
0
60
7511
7512
Note: Disconnecting switch 7111 Disconnecting switch 7112
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00387, .00577, .00578
Ordering information: on HEB 2207511.22 Support for 1 disconnecting switch 15 kV on mast head
Note: Disconnecting switch 7111 Disconnecting switch 7112
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00394, .00579, .00580
Ordering information: on HEB 2007512.20 Support for 2 disconnecting switches 15 kV on mast head
Mast range: Section HEB 160 180 - 240 260
Mast range: Section HEB 160 180 - 240 260
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
80
110 1490
16
06
0
600 600
500
7513
7514
Support for 3 disconnecting switches 15 kV on mast head
Support for 1 disconnecting switch 15 kV mounted on the side of mast
Mast range: Section HEB 160 180 - 240 260
Note: Disconnecting switch 7111 Disconnecting switch 7112
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00394, .00579, .00580
Ordering information: on HEB 2407513.24 Support for 3 disconnecting switches 15 kV on mast head
Mast range: Section HEB 160 - 260
Note: Disconnecting switch 7111 Disconnecting switch 7112
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00480
Ordering information: on HEB 1807514.18 Support for 1 disconnecting switch 15 kV mounted on the side of mast
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Support for 1 disconnecting switch 3,6 kV on mast head
Support for 2 disconnecting switches 3,6 kV on mast head
Support for 3 disconnecting switches 3,6 kV on mast head
110 1360
600 600
110 1360
600 600
110
7541
7542
7543
Note: Disconnecting switch 7141
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00454, .00581, .00582
Ordering information: on HEB 1807541.18 Support for 1 disconnecting switch 3,6 kV on mast head
Note: Disconnecting switch 7141
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00917, .00927, .00930
Ordering information: on HEB 2007542.20 Support for 2 disconnecting switches 3,6 kV on mast head
Note: Disconnecting switch 7141
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00918, .00928, .00933
Ordering information: on HEB 2007543.22 Support for 3 disconnecting switches 3,6 kV on mast head
Mast range: Section HEB 160 180 - 240 260
Mast range: Section HEB 160 180 - 240 260
Mast range: Section HEB 160 180 - 240 260
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
500
500
30
7544
7545
Support for 1 disconnecting switch 3,6 kV mounted on the side of mast
Fastening plates for 1 disconnecting switch 3,6 kV at sectioning point
Mast range: Section HEB 160 - 260
Note: Disconnecting switch 7141
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00490
Ordering information: on HEB 2007544.20 Support for 1 disconnecting switches 3,6 kV mounted on the side of mast
Note: Disconnecting switch 7141
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00391
Ordering information: 7545 Fastening plates for 1 disconnecting switch 3,6 kV at sectioning point
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Gantry for single disconnecting switch on mast head, manually operated
Gantry for 2-3 disconnecting switches on mast head, manually operated
80
110600600
80
110
7611
7612
Note: When ordering, state number of tube guides (2 or 3). Disconnecting switch 7111 o/w Support plate for motor drive 7651
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00599
Ordering information: with 2 rod guides, on HEB 2207611.2.22 Gantry for single disconnecting switch on mast head, operated manually
Note: When ordering, state number of tube guides (2 or 3). Disconnecting switch 7111 o/w Support plate for motor drive 7651
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00600
Ordering information: with 3 rod guides, on HEB 2407612.3.24 Gantry for 2-3 disconnecting switches on mast head, manually operated
Mast range: Section HEB 160 180 - 240 260
Mast range: Section HEB 160 180 - 240 260
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Gantry for single disconnecting switch on mast head, with motor drive
Gantry for 2-3 disconnecting switches on mast head, with motor drive
80
110600600
80
110
7621
7622
Note: When ordering, state number of tube guides (2 or 3). Disconnecting switch 7111 o/w
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00592
Ordering information: with 2 rod guides, on HEB 2207621.2.22 Gantry for single disconnecting switch on mast head, with motor drive
Note: When ordering, state number of tube guides (2 or 3). Disconnecting switch 7111 o/w
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00593, .00593-1 - .00593-8
Ordering information: with 3 rod guides, on HEB 2407622.3.24 Gantry for 2-3 disconnecting switches on mast head, with motor drive
Mast range: Section HEB 160 180 - 240 260
Mast range: Section HEB 160 180 - 240 260
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Gantry for 4-switch sectioning point 15 kV
800 800 800 800 800
4000
N
V
7631
Note: When ordering, state number of rod guides (2 or 3), and also the mast size and mast position (normal = N, turned = V). In the case of motor drive, a metal cover is available on request for cable protection. For 2 field sectioning point: 4 long shank bolts 3251 order separately.
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00595
Ordering information: 2 rod guides 1 mast HEB 200 normal 1 mast HEB 240 turned7631.2.20N.24V Gantry for 4-switch sectioning point 15 kV
Mast range: Section HEB 200 - 260
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
800800800800800800
4800
N
V
7632 Gantry for 5-switch sectioning point 15 kV
Mast range: Section HEB 200 - 260
Note: When ordering, state number of rod guides (2 or 3), and also the mast size and mast position (normal = N, turned = V). In the case of motor drive, a metal cover is available on request for cable protection. For 2 field sectioning point: 4 long shank bolts 3251 order separately.
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00595
Ordering information: 2 rod guides 1 mast HEB 220 normal 1 mast HEB 240 normal7632.2.22N.24N Gantry for 5-switch sectioning point 15 kV
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Gantry for 6-switch sectioning point 15 kV
5600
800 800 800 800 800 800 800
N
V
7633
Note: When ordering, state number of rod guides (2 or 3), and also the mast size and mast position (normal = N, turned = V). In the case of motor drive, a metal cover is available on request for cable protection. For 2 field sectioning point: 4 long shank bolts 3251 order separately.
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00595
Ordering information: 3 rod guides 1 mast HEB 240 normal 1 mast HEB 240 turned7633.3.24N.24V Gantry for 6-switch sectioning point 15 kV
Mast range: Section HEB 200 - 260
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Gantry for 4-switch sectioning point 1,5 - 3,6 kV
700 700600 600 600
3200
N
V
7641
Note: When ordering, state number of rod guides (2 or 3), and also the mast size and mast position (normal = N, turned = V). In the case of motor drive, a metal cover is available on request for cable protection. For 2 field sectioning point: 4 long shank bolts 3251 order separately.
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00596
Ordering information: 2 rod guides 1 mast HEB 200 normal 1 mast HEB 220 turned7641.2.20N.22V Gantry for 4-switch sectioning point 1,5 - 3,6 kV
Mast range: Section HEB 200 - 260
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
N
V
700700 600 600 600 600
3800
7642 Gantry for 5-switch sectioning point 1,5 - 3,6 kV
Mast range: Section HEB 200 - 260
Note: When ordering, state number of rod guides (2 or 3), and also the mast size and mast position (normal = N, turned = V). In the case of motor drive, a metal cover is available on request for cable protection. For 2 field sectioning point: 4 long shank bolts 3251 order separately.
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00596
Ordering information: 2 rod guides 1 mast HEB 220 normal 1 mast HEB 220 normal7642.2.22N.22N Gantry for 5-switch sectioning point 1,5 - 3,6 kV
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Gantry for 6-switch sectioning point 1,5 - 3,6 kV
N
V
700 600 600 600 600 600 700
4400
7643
Note: When ordering, state number of rod guides (2 or 3), and also the mast size and mast position (normal = N, turned = V). In the case of motor drive, a metal cover is available on request for cable protection. For 2 field sectioning point: 4 long shank bolts 3251 order separately.
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00596
Ordering information: 3 rod guides 1 mast HEB 240 normal 1 mast HEB 220 turned7643.3.24N.22V Gantry for 6-switch sectioning point 1,5 - 3,6 kV
Mast range: Section HEB 200 - 260
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
N
V
700 600 600 600 600 600 600 700
5000
7644 Gantry for 7-switch sectioning point 1,5 - 3,6 kV
Mast range: Section HEB 200 - 260
Note: When ordering, state number of rod guides (2 or 3), and also the mast size and mast position (normal = N, turned = V). In the case of motor drive, a metal cover is available on request for cable protection. For 2 field sectioning point: 4 long shank bolts 3251 order separately.
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00596
Ordering information: 2 rod guides 1 mast HEB 240 normal 1 mast HEB 260 turned7644.2.24N.26V Gantry for 7-switch sectioning point 1,5 - 3,6 kV
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Gantry for 8-switch sectioning point 1,5 - 3,6 kV
N
V
700 600 600 600 600 600 600 600 700
5600
7645
Note: When ordering, state number of rod guides (2 or 3), and also the mast size and mast position (normal = N, turned = V). In the case of motor drive, a metal cover is available on request for cable protection. For 2 field sectioning point: 4 long shank bolts 3251 order separately.
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00596
Ordering information: 3 rod guides 1 mast HEB 240 normal 1 mast HEB 240 normal7645.3.24N.24N Gantry for 8-switch sectioning point 1,5 - 3,6 kV
Mast range: Section HEB 200 - 260
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Support plate for motor drive
Support for fastening manual drive
65 65 85
280
212
ø18
65
65
68
ø40
280
6565
130
18
7651
7652
Note: For conversion from manual to motor operation.
Fasteners: Supplied complete with bolts.
Drawing number: 561.00202
Ordering information: 7651 Support plate for motor drive
Fasteners: Supplied complete with bolts.
Drawing number: 561.00221
Ordering information: 7652 Support for fastening manual drive
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type L(mm)
3 3004 4005 500
Flexible connector 300 mm2
Busbar support clamp
46
/16 1
4
16 32
75
L
ø37
M 12
20
11
M 10
7661
7662
Note: Disconnecting switch 7131
Drawing number: 567.00078
Ordering information: Length 400 mm7661.4 Flexible connector 300 mm2
Note: For busbar support with insulator 5154
Drawing number: 458.00029
Ordering information: 7662 Busbar support clamp
Material: Cu tin-plated
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Switch lock assembly 15 kV
Switch lock assembly 1,5 - 3,6 kV
1 1
2 2 2 2
65
800
100
2 2 2 2
1 1
600
7671
7672
Note: Lift 120 mm 1 = Switch lock closed 2 = Switch lock open
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00313
Ordering information: 7671 Switch lock assembly 15 kV
Note: Lift 100 or 120 mm 1 = Switch lock closed 2 = Switch lock open
Fasteners: Supplied complete with U-bolts.
Drawing number: 561.00313
Ordering information: 7672 Switch lock assembly 1,5 kV - 3,6 kV
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type Rated Voltage(V)
10 100015 1500
Bracket for 1 overvoltage arrester, dc
Overvoltage arrester, dc
Lightning protection, 1500 V
R 1
30
350
14
ø17
8/4
0
20
260
40/6
2015
7681
7682
7683
Fasteners: Supplied complete with U-bolts.
Drawing number: 473.00008, .00008-1, .00008-2
Ordering information: on HEB 2007681.20 Bracket for 1 overvoltage arrester, dc
Weight: Wt (kg) = 5,8
Fasteners: Supplied complete with bolts.
Associated parts: Cable lug 4511 o/w
Drawing number: 473.00053
Ordering information: Rated voltage 1,5 kV7682.15 Overvoltage arrester, dc
Weight: Wt (kg) = 5,0
Fasteners: Supplied complete with M 16 x 50 mm bolts.
Associated parts: Cable lug 4511 o/w Mast bracket for steady arm 5411
Ordering information: 7683 Lightning protection 1500 V
Mast range: Section HEB 160 180 - 240 260
Material: Synthetic
Furrer Freyb a u t F a h r l e i t u n g e n
® 06/20
06/20 Furrer Freyb a u t F a h r l e i t u n g e n
®
Type Series U1(V)
U2(V)
f(Hz)
VA Wt(kg)
15 GEF-36 15 230 16,7 30 5125 VEF-52 25 230 50 / 60 200 170
Voltage transformer
320
M12
Typ 15
800
260
200
Ø13
250
1250
M10
Ø18
300
500
175
500
Typ 25
7691
Note: Unipolar insulated cast-resin voltage transformer Outdoor type
Drawing number: 564.00080, .00228
Ordering information: for 15 kV7691.15 Voltage transformer