2
Stealth Watering System Direct Link (FLT-DL) PAK819 Philadelphia Scientific LLC 207 Progress Drive Montgomeryville, PA 18936 P: 215.616.0390 F: 215.616.0500 www.phlsci.com © 201 Philadelphia Scientific LLC. All Rights Reserved. Philadelphia Scientific and the PS logo are registered trademarks of Philadelphia Scientific. Stealth Watering System and Water Injedctor System are trademarks of Philadelphia Scientific LLC. E&O.E.

DirectLink - Philadelphia Scientific · StealthWateringSystem ™ DirectLink (FLT-DL) PAK819 5HY PhiladelphiaScientificLLC 207ProgressDrive Montgomeryville,PA18936 P:215.616.0390

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

StealthWateringSystem™

DirectLink(FLT-DL)

PAK819Rev 3/2016

PhiladelphiaScientificLLC207ProgressDriveMontgomeryville,PA18936P:215.616.0390F:215.616.0500www.phlsci.com

©2016PhiladelphiaScientificLLC.AllRightsReserved.PhiladelphiaScientificandthePSlogoareregisteredtrademarksofPhiladelphiaScientific.StealthWateringSystemandWaterInjedctorSystemaretrademarksofPhiladelphiaScientificLLC.E&O.E.

PAK819:PAK819.qxd 11/27/2013 12:28 PM Page 1

jyum
Typewritten Text
jyum
Typewritten Text
jyum
Typewritten Text
jyum
Typewritten Text
jyum
Typewritten Text
jyum
Typewritten Text
jyum
Typewritten Text
jyum
Typewritten Text
jyum
Typewritten Text
jyum
Typewritten Text
jyum
Typewritten Text
jyum
Typewritten Text

Installation:

Operation:

Do not fill the Direct Link directly from a faucet.

The static water pressure may notexceed 80 PSI (25 bar).

ABall Valve with a 3/4” NPTmale threadedfittingmust be plumbed in to a pressurizedwater line (>3/4” or more in diameter).

Not included

Attach the black sediment filter to theoutlet of the Ball Valve.

Attach the braided hose to the whitemale end of the sediment filter. Do notuse more than 20 ft. of hose.

Attach the Pressure Regulator to theend of the braided hose.

Attach the spinner output to the end of the Pressure Regulator.

Mount included brackets on the wall.

Turn water source on at the ball valve. Connect the Direct Link to the InputAssembly of the Stealth WateringSystem installed on the battery.

When the system is connected, fillingwill begin automatically.

Watch the spinner, when it stopsspinning, the filling is completed.

Disconnect the Quick-Connect to stopflow to the Stealth Watering System.

Move on to the next battery. Whenfinished watering batteries, turn thewater off at the ball valve.

The Philadelphia Scientific Stealth Water System requires pressure from 3-45 psi. If your water source does not meet these requirements, you will need to purchase an alternative to the Direct Link.

PAK819:PAK819.qxd 11/27/2013 12:28 PM Page 2

jyum
Typewritten Text
jyum
Typewritten Text
jyum
Typewritten Text