Digital ThermostatModels: VS30W and VS30B
I N S TA L L E R / U S E R M A N U A L
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
02 VS30W and VS30B Installer / User Manual
Contents
VS301 x Installer / User manual
Digital ThermostatModels: VS30W and VS30B
I N S TA L L E R / U S E R M A N U A L
Fixing screws
ContentsBox ContentsIntroductionProduct ComplianceInstallation User GuideParameter SettingsInstallers NotesWarranty
Box Contents
Icons used in this manual:
Safety
Important info
Your benefit
For latest PDF installationguide please go towww.salus-controls.com
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
Product Compliance & Safety Information
INTRODUCTION
Thank you for purchasing the room thermostatVS30. The VS30 is a 230V digital thermostatwhich offers simple temperature control of yourheating system.
By purchasing the VS30 you have decided on adigital room thermostat which allows you toadjust surface heating appliances individually,such as underfloor, wall or panel heating.A clear energy saving is possible by reducingtemp.
Product Compliance
This product is CE compliant and meets thefollowing EC Directives Electro-MagneticCompatibility Directive 2004/108/ECLow voltage Directive 2006/95/EC
Safety Information Use in accordance with the regulations.The VS30 is to be used for roomcontrol of hot water heating systemsinside the house.
Installation
This product must be fitted by a competentperson, and installation must comply with theguidance, standards and regulations applicableto the city, country or state where the productis installed. Failure to comply with therequirements of the relevant guidance,standards and regulations could lead to injury,death or prosecution.
Always isolate the AC mains supplybefore installing or working on any componentsthat require 230V AC 50Hz supply.
We hope you enjoy this product...
VS30W and VS30B Installer Manual 03
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
Product Compliance & Safety Information
Sources of danger
The thermostat must be disconnected from mainssupply before removing the cover.
230V AC
Emergency
Switch off the voltage to the indivdual thermostatwring centre or complete system.
Installer parameter settings
The VS30 is equippedwith installer parameter section.This must only be enteredby the installer or competentperson. Changing these parameterscan have a serious effect on your heating system. See page 41.
For the installer
Please enter any parameterchanges in the installer notes section.
04 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
Installation – Terminal Connections
Understanding your terminal connections
Rear of VS30
Power Terminals 230 VacUsed for supplying power to theunit and switched output.
NSB (Night Set Back) ConnectionUsed for a 230V output to otherthermostat. See page 8.
Sensor Terminals S1, S2 (Optional)Can be used for external AIRor Floor sensor.
1
33 2 1
2
VS30W and VS30B Installer Manual 05
INSTA
LLATIO
N
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
Installation – Thermostat Mounting
1
3
2
60mm
Wall MountingFor wall mounting, mark andmount the rear case to the wall.The VS30 is suitable for wall boxeswith a centre hole distance of : 60mm
Gently remove front housing.
06 VS30W and VS30B Installer Manual
Gently remove front housing.
Only for flushmounting boxeswith horizontalfixing holes.
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
Installation – Thermostat Mounting
Not to be positioned on an exterior wall.
130cm
Mounting position and installationTo ensure trouble free operation and efficient control, the VS30 room thermostat is best positionedin a draft free area, and at 130cm from the floor. Do not position the thermostat near any heatsource, behind curtains, direct sunlight or an area of high humidity.
VS30W and VS30B Installer Manual 07
INSTA
LLATIO
N
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
08 VS30W and VS30B Installer Manual
S2
S1
NSB
SL
L
N
S2
S1
NSB
SL
L
N
Sensor Terminal (optional)
Sensor Terminal (optional)
Night set back output
Load (Thermal Actuators)
Live 230V AC 50Hz
Neutral
L NWiring Centre
ThermalActuator
Optional SALUSSensor
Installation – Terminal Connections
L N
NSB for otherthermostats
Output
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
Installation – Terminal Connections
Power Terminals
NSB (Night Set Back) Connection
Sensor Terminals (if applicable)
You are ready to secure the rear housing to the wall box
Check that the wiring is completed for:
1
2
3
Please use the screws provided
Ensure the orientation arrowis pointing upwards.
VS30W and VS30B Installer Manual 09
INSTA
LLATIO
N
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
Installation – Thermostat Mounting
1
Fit the front housing to the rear housing
Align the front housing at the top edge.
2 Lightly press until youhear a positive click.
Ensure the pin connections are aligned
10 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
Installation – LCD Graphics1 2 3 4 5 6 7
8
9
11
12
14
13
10
1615
VS30W and VS30B Installer Manual 11
INSTA
LLATIO
N
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
ICON FUNCTION
BOX means to select the mode e.g. means the current setpoint is Hi temp, means the Hi temp is not selected.
Sunny: Hi comfortable temperature.
Cloudy: Middle comfortable temperature.
Moon: Low comfortable temperature.
Programmable thermostat Program mode indicator: Indicates program is running,Auto On or Auto Off. For group thermostat this indicates that it is a member of a group.
Party indicator:When Party mode is active.
Vacation indicator:When Vacation mode is active.
Frost protection indicator: Frost protection is active, not available in cooling mode (if applicable).
Installation – LCD Graphics
123
4
5
6
7
12 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:48
Installation – LCD Graphics
ICON FUNCTION
Heat indicator:Indicates heat is required.
Cool mode indicator: Indicates cooling is required (if applicable).
Temperature indicator:Display the room temperature.Display the set-temp.Also used to show the other information.
Temporary manual override indicator:If the set temperature is changed when in program mode, the hand will appear until the next program start time.
Programs number indicator: In AUTO program mode or Temporary override is running, it means the current program running.
Day indication: 1 = Monday.
8
9
10
11
12
13
VS30W and VS30B Installer Manual 13
INSTA
LLATIO
N
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
Installation – User Interface
ICON FUNCTION
Floor sensor probe indicator: Show only when Air + Floor sensor is connected.
Setting indicator: Indicates the unit is in setting mode when program setting.Indicate’s the manual mode.
Keylock indicator:Shows that keys are inactive.
14
15
16
14 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
Installation – User Interface
KEY FUNCTION
1. Increase or decrease setpoint temperature.2. Increase or decrease Day, Clock, Timer, Party and Holiday.3. Select installer parameter value.
1. Mode selection.2. Long press to return to home display without saving.3. Short press to return to the previous screen when it is in user/installer setting mode.
1. OK key: Short press to confirm selection.2. Long press to save and exit.3. Long press to enter the user settings.
Lock/Unlock.
Enter Installer parameter settings.
Test mode.
OR
+
+ +
5 SECONDS
5 SECONDS
5 SECONDS
+
OR
VS30W and VS30B Installer Manual 15
INSTA
LLATIO
N
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
Installation – First Power Up
16 VS30W and VS30B Installer Manual
2 Seconds
2 Seconds
Software Version
Time Setting
ON first power up.Proceed to page 19
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
Installation - Graphics Key
Press once
Press x amount of times
Hold for five seconds
Flashing
xx
Short press to save andlong press to save and exitShort press to back up
VS30W and VS30B Installer Manual 17
INSTA
LLATIO
N
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Setting time and date
18 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Setting time and date
Use left to select 12hour and right to
select 24 hour.
Adjust the timeusing the up or
down arrow key.
VS30W and VS30B Installer Manual 19 USER
GUIDE
Hour
Minutes
YearMonth
Day
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide – Understanding Temperature Levels - Heating
Highest Temperature typically used for early morning and early evening. Typically 20 Deg C
Mid Temperature typically used for times of day when you are active around the home. Typically 19 Deg C
Lower Temperature typically used for unoccupied or sleep times.Typically 17 Deg C for UFH or 15 Deg C for radiators
Frost Temperature typically used forperiods of long absence or holidays.Typically 5 Deg
Your thermostat comes preset for the above temperatures. These can be adjusted. Please see page 37.
20 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Understanding Temperature Levels - Cooling
Occupied Temperature. Typically 22ºC
Unoccupied Temperature Typically 40ºCThis avoids cooling being active when the property is unoccupied.
Evening Temperature Typically 26ºC
Your thermostat comes preset for the above temperatures. These can be adjusted. Please see page 37.
See device setting D18, section on page 44
VS30W and VS30B Installer Manual 21 USER
GUIDE
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Default Heating Schedule .1
21
19
17
12.00 6.00 9.00 16.00 23.00
Monday to Friday
21
19
17
12.00 7.00 23.00
Saturday to Sunday
22 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Optional Heating Schedule .2
21
19
17
12.00 6.00 22.30
Monday to Friday
21
19
17
12.00 7.00 23.00
Saturday to Sunday
VS30W and VS30B Installer Manual 23 USER
GUIDE
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Optional Heating Schedule .3
21
19
17
12.00 5.00 8.00 14.00 22.00
Monday to Friday
21
19
17
12.00 7.30 22.30
Saturday to Sunday
24 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Optional Heating Schedule .4
21
19
17
12.00 6.00 9.00 15.00 22.30
Monday to Friday
21
19
17
12.00 7.30 23.00
Saturday to Sunday
VS30W and VS30B Installer Manual 25 USER
GUIDE
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Optional Heating Schedule .5
21
19
17
12.00 6.00 10.00 16.00 23.00
Monday to Friday
21
19
17
12.00 7.30 23.30
Saturday to Sunday
26 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Default Cooling Schedule .1
22
40
26
12.00 6.00 9.00 16.00 23.00
Monday to Friday
22
40
26
12.00 7.00 23.00
Saturday to Sunday
VS30W and VS30B Installer Manual 27 USER
GUIDE
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Optional Cooling Schedule .2
22
40
24
12.00 6.00 22.30
Monday to Friday
22
40
24
12.00 7.00 23.00
Saturday to Sunday
28 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Optional Cooling Schedule .3
22
40
24
12.00 5.00 8.00 14.00 22.00
Monday to Friday
22
40
24
12.00 7.30 22.30
Saturday to Sunday
VS30W and VS30B Installer Manual 29 USER
GUIDE
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Optional Cooling Schedule .4
22
40
24
12.00 6.00 9.00 15.00 22.30
Monday to Friday
22
40
24
12.00 7.30 23.00
Saturday to Sunday
30 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide - Optional Cooling Schedule .5
22
40
24
12.00 6.00 10.00 16.00 23.00
Monday to Friday
22
40
24
12.00 7.30 23.30
Saturday to Sunday
VS30W and VS30B Installer Manual 31 USER
GUIDE
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
SYSTEMUser Guide – Setting the Temperature Schedule
Use right and left toselect the day of the
programs.
5/2
7 Days
Individual
32 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:49
User Guide – Setting the Temperature Schedule
Adjust the timeusing the up or
down arrow key.
Use right and left toselect the Hi/Mid or
low temp.
VS30W and VS30B Installer Manual 33 USER
GUIDE
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
User Guide – Setting the Temperature Schedule
When you set the temperature, the schedule will respondto those temperatures. See page 37 on how to change
Repeat through to program 4.If you require a 5th or 6th program enter a timeand select your temperature
To remove a program out set the time to --:--.
34 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
User Guide - Temporary Override
Use the up or downarrow key to viewyour program set
temperature.
Use the up or downarrow key to adjustthe temperature to
the setting youdesire.
Temporary override allows you to increase the temperature or decreaseit to the desired setting until it reverts back on the next program time.
VS30W and VS30B Installer Manual 35 USER
GUIDE
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
User Guide - Temporary Override
To cancel temporary override press orSee below.
Confirm thetemporary settemperature.
36 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
User Guide - Permanent Override
To cancel permanent override selectSee below.
Move from
toUse the up or downarrow key to view
your set temperature.See page 35.
To adjust yourpermanent overridetemperature follow
the steps on page 35.
Repeat for if required
Setting permanent low temperature
VS30W and VS30B Installer Manual 37 USER
GUIDE
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
User Guide - Party Mode
The party mode is anoption that enables
temperaturefor a period of time.You select up to 9hr50min.
Use the rightarrow to selectthe party mode.
Use the uparrow to selectthe hr/min.
Press tick toconfirm andit will start tocount down .
38 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
User Guide - Holiday Mode
Use the right arrowto select the holidaymode.
Use the up arrow toselect how manydays to be off for.
Press tick to confirmand it will start theholiday count down.
VS30W and VS30B Installer Manual 39 USER
GUIDE
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
User Guide - Frost Protection
Use the right arrowto select the frostmode.
Use the up arrow toselect the frostprotectiontemperature.
Press tick to confirmthe temperaturethat it has beenset to.
40 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
Installation - Entering Device Menu
If you need tochange device
parameters followthe steps below.
Must only beentered by the
installer.
This is the firstscreen of thedevice menu.
Press all threebuttons
simultaneously.
VS30W and VS30B Installer Manual 41
INSTA
LLATIO
N
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
Installation - Device Parameters
DX FUNCTION SYSTEM SETTING DEFINITION DEFAULT
D01 Heating 0 Pulse Width ModulationControl 1 On-Off 0.5 Deg C +/- 0.25 Deg C 0
2 On-Off 1.0 Deg C +/- 0.5 Deg C
D02 Room -3.0 to 3.0 Temperature Offset from Temperature Deg C Measured Temperature to 0 Deg C
Offset Compensate for any error
D03 Sensor probe or 0 Sensor stat not Connected Cylinder thermostat 1 Sensor stat Connected 0
connection
D04 Sensor probe 0 D03 must be set to 1 then used as air sensor external sensor be used as
or floor sensor Air sensor. There will be nointernal temp measurement 01 D03 must be set to 1 thenexternal sensor used for floorprotection. Internal temp is
measured by stat
D05 Cooling Control 1 On-Off 0.5 Deg C +/- 0.25 Deg C 22 On-Off 1.0 Deg C +/- 0.5 Deg C
D06 Actuator type 0 NO Normally Open 11 NC Normally Closed
D07 Valve protection 0 Disable 11 Enable
42 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
Installation - Device Parameters continued
DX FUNCTION SYSTEM SETTING DEFINITION DEFAULT
D08 Frost Set point 5-17 Deg C Required Temperature for frost 5 DegTemperature protection and holiday mode
D09 Hour Format 0 12 11 24
D10 N/A N/A N/A N/A
D11 Daylight Saving 0 OFF 1Time (DST) 1 ON
D12 Heating Set point 5-35 Deg C Maximum temp that can 35 Deg CLimit be set for heating
D13 Cooling Set point 5-40 Deg C Maximum temp that can 5 Deg CLimit be set for Cooling
D14 Floor sensor High Output relay will be switched off Limit Temperature 6-45 Deg C when temp is reached for 27 Deg C
floor protection
D15 Floor sensor Low Output relay will be switched on Limit Temperature 6-45 Deg C when temp is reached for 10 Deg C
floor protection
D16 Floor sensor Limit Output relay will be switched off for cooling 6-45 Deg C when temp is reached for 6 Deg C
floor protection
VS30W and VS30B Installer Manual 43
INSTA
LLATIO
N
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
Installation - Device Parameters continued
DX FUNCTION SYSTEM SETTING DEFINITION DEFAULTD17
D18
Preset programselection 1-5 Select 1-5 of the default programs 1
Heat/Cool modeselection 0 or 1 0: heating mode
1: cooling mode 0
44 VS30W and VS30B Installer Manual
Enter Number 47and press
Press all threebuttons
simultaneously.
ERROR DESCRIPTION
Maximum/Minimum Floor Temp Reached
Broken Floor Sensor
Floor Sensor Short Circuit
Must only beentered by the
installer.
Reset to factory settings
ERROR CODE
Err02
Err03
Err04
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
Installation - Technical Detail
VS30W and VS30B Installer Manual 45
INSTA
LLATIO
N
Model Basicline TType Electronic programmable room thermostat, digital room
thermostat designed for 230V AC applicationsProgramming Modes User selectable for 5/2, ALL and Individual day options
Program Number 1-6 SelectableModes Party, Vacation, Program and FrostNSB 230V OutputOverride Permanent and temporaryFrost Protection 5ºC AdjustablePower Source 230V AC 50HzRating 3 AmpTemperature Scale 5 to 35ºC, tolerance 0.5ºCHeat/Cool Local changeover Sensor Air or floor protection.Device Parameters See page 42 for full list of functionsOperating Temperature 0 to 50ºCStorage Temperature -20 to 60ºC
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
Installation - Notes
46 VS30W and VS30B Installer Manual
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shallperform in accordance with its specification, for a period of five years from the date of installation. SALUS Controlssole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
Customer Name: .............................................................................................................................
Customer Address: ..........................................................................................................................
............................................................................... Post Code: ........................................................
Tel No: ........................................................ Email: .........................................................................
Engineers Company: .......................................................................................................................
Tel No: ......................................................... Email: ........................................................................
Installation Date: ..............................................................................................................................
Engineers Name: ............................................................................................................................
Engineers Signature: .......................................................................................................................
Warranty
VS30W and VS30B Installer Manual 47
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50
www.salus-controls.com
SALUS Controls plcSALUS HouseDodworth Business Park South,Whinby Road,Dodworth, Barnsley S75 3SP, UK.
SALES: T: +44 (0) 1226 323961E: [email protected]
TECHNICAL: T: +44 (0) 1226 323961E: [email protected]
Issue Date: April 2014
Maintaining a policy of continuous product development SALUS Controls plc reserve the right tochange specification, design and materials of products listed in this brochure without prior notice.
SALUS Controls is a member of the Computime Group
00086/2
iT600 VS30W - VS30B Installer - User Manual 016_Layout 1 03/09/2014 10:50