DSE3110

HGM6120U

Water temperature Sensor

Floating charge

Oil temperature heating

HGM170

ESD5500E

Oil pressure sensor

Generator diode set

Coolant temperature heating

DSE6020

SX440 AVR

Stop switch

Antivibration

ATS Switch

DSE7320

SX460AVR

Engine magnetic valve

Engine filter

ATS Switch box

DIESEL GENERATION AUSTRALIA

Diesel Generation Australia is a supplier of Diesel & Gas Generators. We are the Tasmanian agent for Pramac & Generac range of Generators and are a leading importer & supplier of Cummins & Perkins Diesel Generators.

With a power range from 1KVA through to 3500KVA. This includes Open Type, Sound Proof, Super Silent, Trailer and Container Type Generators.

Our generators are accredited to ISO & CE certification and we pride ourselves on our ability to provide our products efficiently and effectively.

Our Tasmanian owned company, delivers cost effective solutions to you direct.

We offer outright purchases, hire and full back-up service.

Our flexibility and impeccable customer service is what sets us apart from the competition.

SERVICE & SUPPORTDGA provides a unique maintenance service & breakdown response unit 7 days a week. Our experienced and qualified technicians can be on hand at anytime, to make sure that you are supported throughout your purchase or rental agreement.

With a fully equipped workshop and service vehicle, we can come to you anywhere, anytime.

DGA provides obligation free quotes at no cost, so you can confidently compare your options.

DGA strives to deliver excellence and expertise, in all customer interactions and that is why, you will deal directly with the business owners.

Page 3: DIESEL GENERATION AUSTRALIA GENERATOR PARTSdgaus.com.au/wp-content/uploads/2016/05/NEW DGA catalogue(1).pdf · DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA GENERATOR PARTS

DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA

1. Engine

2. Air cleaner

3. Control cabinet

4. Alternator

5. Switch cabinet

6. Battery

7. Base frame

Standard Features8. Mouting flange of vent-pipe

9. Water inlet

10. Radiator

11. Lifting lug

12. Fuel inlet

13. Fuel lever meter

14. Vibration isolator

RELIABLE AND SAFE ● Powered by world famous engines, such as Cummins and Perkins.

● Load from 0-100% frequencey vibration with +/-0.25%.

● No load wire volts max undulation ratio with 0.5%.

● The fully covered load centre houses all the outlets, compression terminals and circuit breakers.

● Fully PC or front panel configuration, with automatic shutdown, when a fault occurs.

EXCELLENT COOLING SYSTEM ● Exhaust silencing system, totally enclosed for operators safety.

● 500C radiator as standard, oil cooler and drain tap.

AUTOMATIC AIR-BLEEDING ● Every time the engine key is turned ON, air is automatically purged from the fuel system.

Open generator sets with power range fron 9KVA to 2500KVA ● The Control cabinet and wiring cabinet are desiged separately and placed

onto the alternator.

● Compact structure and easy transportation.

● Stable performance and long service life.

● Strong power, large output power, suitable for heavy duty.

Optional ATS/Paralleling system communication connecting ● Use the paralleling communication line to connect the two parallelling connectors on genset 1 & genset 2

● In the same way, connect paralleling connectors between every two gensets, from genset 2 to last.

Number of paralleling gensets is different according to control module used in the genset.

Open type genset Soundproof type genset

CIRCUIT

BREAKER

ELECTRIC

START

DC.12/24V

DSE3110 DES6020 AMP DSE8610Paralleling System

Control Module

Max. number of paralleling units

PLC-8610

32

Genset 1

L1 L2L3NOR

U V W O

LOAD

Genset 2

Genset N

LOAD

Paralleling connector

Paralleling communication line

Notes:1. A PLC-6020/PLC-3120 or PLC-3110 is the standard configuration, while PLC-8610 is optional

and is used for automatic parallel operation.2. Applicable voltmeter, ampere meter and other meters are indispensable for

the PLC-3110 system.3. PLC-620U/PLC-7320 optional multiple languages.

VoltsFail to

StartCurrentTemp

Emer-gency stop

Freq.SpeedLow Oil

PressureAMPControl

System

PLC-3110 x STD STD STD STD STD STD STD STD

PLC-8610 STD STD STD STD STD STD STD STD STD

PLC-6020 PLC-6120 STD STD STD STD STD STD STD STD STD

Page 4: DIESEL GENERATION AUSTRALIA GENERATOR PARTSdgaus.com.au/wp-content/uploads/2016/05/NEW DGA catalogue(1).pdf · DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA GENERATOR PARTS

DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA

The Noise level can be reduced by 15-35dB(A) through multiple noise control devices, which ensure quiet operations, thus having no effect on daily activities. This feature makes our diesel generators ideal for use at night in a residential area, offices and other environment which are sensitive to noise.

Cleaner exhaust, less effect on the environment. Even in outdoor applications.

POWERFUL ENGINES ● Adopts world famous engines, with low noise and low emission.

● Rugged structure ensures lowest vibration.

● Common rail system: (for some models) significantly lowers the combustion temperature and also leads to cleaner exhaust.

● For the turbocharged machines, the carbon dioxide(CO2) emission is reduced.

EXCELLENT SILENCERSSilencer and muffler pipe system effectively reduces the noise during operation, allowing for uninterrupted operations.

FULLY-CLOSED NOISE REDUCTIONBesides applying air proof rubber around the doors, the concept of noise reduction has also been fully integrated into the inlet/outlet and all other components.

HIGH QUALITY SOUND ABSORBING MATERIALThe interior is lined with a new type fire retardant and sound absorbing cotton and the door is air proof with rubber, which helps absorb noise and heat during operation.

Environmentally Friendly

Easy to OperateCONTROL SYSTEM

● Micro-processor cored digital system.

● Multiple languages, automatic control.

● Connected with the mains through ATS, which can help realize automatic transfer between the mains and the generators. Also, multiple generators can be paralleled for bigger power needs.

● Outer filling fuel port.

● 8-12 hours base fuel tank in soundproof generator sets prevents against leakage and fuel spray when cleaning the interior. The Fuel tank abides by European environment protection standards.

● Drainage outlet.

● Water feeder is located on top of the canopy.

EASY TO TRANSPORT ● The machines below 500KVA have forklift holes and dragging points in the base for easy transport.

● Lifting eyes are located on top of canopy, making the machine easier to move by cranes.

EASY TO MAINTAIN ● The daily maintenance work can be performed on both sides of the machine and the wide doors allow easy access to all areas of the machine.

● An integrated waste drainage outlet located at the bottom of the machine makes it easier to monitor and service.

RELIABLEExcellent engines and alternators featured with string power, high torque, quick start, easy maintenance and operation.

The canopies are made of high quality steel and powder coated. The paint is highly durable against erosion and scratches and is rustproof.

Standard Features

1. Coolant inlet

2. Exhaust gas outlet

3. Roping lug

4. Lifting lug

5. Air inlet

6. Fuel inlet

7. Cable trench

8. Control cabinet

9. Emergency stop switch

10. Fuel drain

11. Fork lift channel

12. External fuel inlet return hose fitting

13. Tie down

14. Coolant/Oil drain hose fitting

15. Access door

16. Base frame

Optional Trailer:1. Off Road Tyre Trailer

2. On Road Type Trailer

3. Trailer Braking System

10KVA - 360KVA

300KVA - 650KVA

Page 5: DIESEL GENERATION AUSTRALIA GENERATOR PARTSdgaus.com.au/wp-content/uploads/2016/05/NEW DGA catalogue(1).pdf · DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA GENERATOR PARTS

DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA

Safe, Simple & Convenient

Safe & Practical Design

CONVENIENT REFUELING and WATERING INSTALLATIONS

● Outer fuel inlet and coolant inlet.

● The genset is equipped with daily-used

double-deck fuel tank with automatic fuel

injection system.

● Fuel outlet at the base and drainage device.

EASY TO MAINTAIN ● The daily maintenance work can be

performed on two sides of the machine and

wide doors allow for easy access.

● Equipped with a climbing ladder, making it

easier for regular maintenance and servicing.

EASY TO TRANSPORT ● Transportation holes for forklift designed in

the base of some sets, makes it easier to move

and transport. Especially helpful for rental

applications.

CONTROL SYSTEM ● Micro-processor cored digital system

● Automatic control for multiple languages.

CONVENIENT CONNECTION ● An optional external quick connection panel

can aid in the monitoring of mains, ATS

transfer and remote start.

1. Coolant inlet

2. Cooling fan plate

3. Exhaust gas outlet

4. Lifting lug

5. Air inlet

6. Access door

7. Control & field wiring cabinet

8. Emergency stop switch

9. Fuel inlet

10. Ladder

11. Water/oil drain hose fitting

12. Fixing lug

Fan and fan motor

Interior of the genset

Superior engine

Control panel

Ventilating fan

Sieve for air inlet and outlet

Fuel loading system (Manual/Automatic, standard configuration)

Built-in sound absorbing cotton

1. Output cables (Genset 1)

2. Telecommunication Cable for Paralleling

3. Output Cables (Genset 2)

Genset 1

Genset 2

● Quiet and suitable for use at night and in residential areas, which are sensitive to noise.

● The extremes of rain and dust is pr evented in harsh environments such as mines, deserts, building sites, etc.

EASY TO BE PARALLELED

CIRCUIT

BREAKER

ELECTRIC

START

DC.12/24V

Page 6: DIESEL GENERATION AUSTRALIA GENERATOR PARTSdgaus.com.au/wp-content/uploads/2016/05/NEW DGA catalogue(1).pdf · DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA GENERATOR PARTS

DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA

C-25 25 20 28 22 4B3.9-G1 PI144E 1700*800*1200 2000*1000*1250 1050

C-30 30 24 33 26 4BT3.9-G1 PI144G 1750*800*1200 2300*1000*1250 1080

C-38 38 30 41 33 4BT3.9-G1 PI144J 1750*800*1200 2300*1000*1250 1120

C-50 50 40 55 44 4BTA3.9-G2 UCI224D 2000*800*1300 2600*1000*1250 1350

C-60 60 48 66 53 4BTA3.9-G11 UCI224A 2000*800*1300 2600*1000*1450 1400

C-73 73 58 80 64 4BTA3.9-G11 UCI1224F 2000*800*1300 2600*1000*1450 1520

C-85 85 68 94 75 6BT5.9-G1 UCI224G 2150*900*1400 2800*1000*1500 1600

C-100 100 80 110 88 6BT5.9-G1 UCI274C 2150*900*1400 2800*1000*1500 1650

C-114 114 91 125 100 6BTA5.9-G2 UCI274D 2150*900*1400 2800*1000*1500 1700

C-130 130 104 143 114 6BTAA5.9-G2 UCI1274E 2300*900*1400 3200*1100*1600 1800

C-150 150 120 165 132 6BTAA5.9-G12 UCI274F 2300*900*1400 3200*1100*1600 1880

C-160 160 128 175 140 6CTA8.3-G1 UCI274F 2400*900*1500 3400*1120*1800 2020

C-175 175 140 193 154 6CTA8.3-G1 UCI274G 2400*900*1500 3400*1120*1800 2080

C-200 200 160 220 176 6CTAA8.3-G2 UCI274H 2600*1000*1650 3600*1200*1800 2450

C-225 225 180 248 198 6LTAA8.9-G2 UCDI274J 2600*1000*1650 3600*1200*1800 2550

C-250 250 200 275 220 6LTAA8.9-G3 UCDI274k 2600*1000*1650 3600*1200*1800 2600

C-250 250 200 275 220 NT855-GA UCDI274K 3000*1120*1650 3900*1400*2000 3400

C-131 313 250 344 275 NTA855-G1B HCI444ES 3000*1120*1650 3900*1400*2000 3750

C-350 350 280 385 308 NTA855-G2A HCI444E 3000*1120*1650 3900*1400*2000 3900

C-375 375 300 416 330 NTAA855-G7 HCI444FS 3300*1120*1800 3900*1400*2000 4000

C-400 400 320 440 352 6ZTAA13-G2 HCI444F 3400*1360*2000 5000*1800*2250 5200

C-450 450 360 495 396 6ZTAA13-G4 HCI544C 3400*1360*2000 5000*1800*2250 5280

C-450 450 360 495 396 KTA19-G4 HCI544C 3400*1360*2000 5000*1800*2250 5300

C-500 500 400 550 440 QSZ13-G3 HCI544D 3400*1360*2000 5000*1800*2250 5310

C-500 500 400 550 440 KTA19-G4 HCI544D 3400*1360*2000 5000*1800*2250 5320

C-575 575 460 633 506 KTAA19-G4 HCI544E 3600*1550*2220 5000*1800*2450 5500

C-650S 590 472 650 520 KTA19-G8 HCI544E 3600*1550*2200 5000*1800*2450 5580

C-650 650 520 715 575 QSKTAA19-G3 NR2 HCI544F 3600*1550*2200 5000*1800*2450 5800

C-750 750 600 825 660 KTA38-G2 LVI634C 4500*1850*2300 6050*2435*2589 (20GP) 9300

C-800 800 640 880 704 KTA38-G2B HCI634G 4500*1850*2300 6050*2435*2589 (20GP) 9500

C-900 900 720 990 792 KTA38-G2A HCI634H 4500*1850*2300 6050*2435*2589 (20GP) 9700

C-1000 1000 800 1100 880 KTA38-G5 HCI634J 4500*1850*2300 6050*2435*2589 (20GP) 9900

C-1250S 1125 900 1250 1000 KTA38-G9 LVI634G 4500*1850*2300 6050*2435*2589 (20GP) 11300

C-1250 1250 1000 1375 1100 KTA50-G3 LVI634G 5620*2280*2350 12192*2435*2896 (40HP) 12000

C-1400 1400 1120 1540 1232 KTA50-G8 PI734B 5620*2280*2350 12192*2435*2896 (40HP) 13000

C-1500 1500 1200 1650 1320 KTA50-GS8 PI734C 5620*2280*2350 2192*2435*2896 (40HP) 13500

C-30 30 24 33 26 4B3.9-G2 PI144E 1700*800*1200 2000*1000*1250 1050

C-40 40 32 44 35 4BT3.9-G2 PI144H 1750*800*1200 2300*1000*1250 1080

C-60 60 48 66 53 4BTA3.9-G2 UCI224D 2000*800*1300 2600*1000*1450 1350

C-73 73 58 80 64 4BTA3.9-G11 UCI224E 2000*800*1300 2600*1000*1450 1400

C-85 85 68 94 75 4BTA3.9-G11 UCI224F 2000*800*1300 2600*1000*1450 1520

C-100 100 80 110 88 6BT5.9-G2 UCI224G 2150*900*1400 2800*1000*1500 1600

C-114 114 91 125 100 6BTA5.9-G2 UCI274C 2150*900*1400 2800*1000*1500 1700

C-125 125 100 138 110 6BTA5.9-G2 UCI274D 2150*900*1400 2800*1000*1500 1750

C-160 160 128 176 141 6BTAA5.9-G12 UCI274E 2300*900*1400 3200*1100*1600 1880

C-180 180 144 198 158 6CTA8.3-G2 UCI274F 2400*900*1500 3400*1120*1800 2080

C-200 200 160 220 176 6CTAA8.3-G2 UCI274G 2600*1000*1650 3600*1200*1800 2450

C-225 225 180 248 198 6LTAA8.9-G2 UCI274H 2600*1000*1650 3600*1200*1800 2550

C-250 250 200 275 220 6LTAA8.9-G3 UCI274H 2600*1000*1650 3600*1200*1800 2600

C-313 313 250 344 275 NT855-G1 UCDI274K 3000*1120*1650 3900*1400*2000 3480

C-350 344 275 378 303 NTA855-G1B HCI444D 3000*1120*1650 3900*1400*2000 3750

C-375 375 300 413 330 NT855-G3 HCI444D 3000*1120*1650 3900*1400*2000 3900

C-400 400 320 440 352 6ZTAA13-G2 HCI444ES 3400*1360*2000 5000*1800*2250 5200

C-450 450 360 495 396 6ZTAA13-G4 HCI444FS 3400*1360*2000 5000*1800*2250 5280

C-500 500 400 550 440 QSZ13-G3 HCI444F 3400*1360*2000 5000*1800*2250 5350

C-590 588 470 646 517 KTAA19-G5 HCI544D 3600*1500*2200 5000*1800*2450 5600

C-688 688 550 750 600 QSKTAA19-G3 NR2 HCI544E 3600*1500*2200 5000*1800*2450 5800

C-750 750 600 825 660 KTA38-G HCI544FS 4500*1850*2300 6050*2435*2589 (20GP) 9300

C-900 900 720 990 792 KTA38-G2 HCI634GD 4500*1850*2300 6050*2435*2589 (20GP) 9500

C-1000 1000 800 1100 880 KTA38-G2A HCI634H 4500*1850*2300 6050*2435*2589 (20GP) 9700

C-1125 1125 900 1238 990 KTA38-G4 HCI634J 4500*1850*2300 6050*2435*2589 (20GP) 11300

C-1300 1300 1040 1430 1144 KTA50-G3 HCI634K 5620*2280*2350 12192*2435*2896 (40GP) 13000

C-1500 1500 1200 1650 1320 KTA50-G9 PI734A 5620*2280*2350 12192*2435*2896 (40GP) 13500

Voltage is optional

400V / 50Hz / 1500RPM Cummins Diesel Engine Alternator Open type Soundproof type Genset 400V / 50Hz / 1500RPM Cummins Diesel Engine Alternator Open type Soundproof type Genset

Prime Standby Prime Standby Packing (mm) Packing (mm) Weight Packing (mm) Packing (mm) Weight

(L X W x H) (L X W x H) KG (L X W x H) (L X W x H) KG KVA KW KVA KW KVA KW KVA KWModel Brand Model BrandStamford Stamford

Model Model

Powered by CumminsSpecification:

Powered by Cummins60Hz50Hz

Notes:

- All ratings are for guidance only.

- All ratings data is based on operation under ISO 8528, ISO 3046, DIN6271 conditions using typical fan sizes and drive ratios. Performance tolerance quoted is +/-5%.

- The ATS is based on the following standards: three phase gensets (380-480V), single phase gensets (220-240V).

- Also available in the following voltages: 1P 220V/230V/240V: 3P 380V/220V, 400V/230V, 415V/240V, 440V/254V.

Voltage is optional

Page 7: DIESEL GENERATION AUSTRALIA GENERATOR PARTSdgaus.com.au/wp-content/uploads/2016/05/NEW DGA catalogue(1).pdf · DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA GENERATOR PARTS

DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA

CIRCUIT

BREAKER

ELECTRIC

START

DC.12/24V

RELIABLE AND SAFE ● Powered by th world famous engine Perkins.

● Load from 0-100% frequencey vibration with +/- 0.25%.

● No load wire volts max undulation ratio with 0.5%.

● The fully covered load centre houses all the outlets, compression terminals and circuit breakers.

● Fully PC or front panel configuration, with automatic shutdown, in the case a fault condition may occur.

45 -650KVA

9 - 27KVA

Standard Features

1. Engine

2. Air cleaner

3. Alternator

4. Control Cabinet

5. Battery

6. Base

7. Mounting flange of vent-pipe

8. Coolant inlet

9. Radiator

10. Lifting lig

11. Vibration isolator

P-10 9 7.2 10 8 403A-11G1 PI044E 1200*600*950 1700*860*1060 460

P-13 12.5 10 13.8 11 403A-15G1 PI044F 1200*600*950 1700*860*1060 530

P-15 15 12 17 13.3 403A-15G2 PI044G 1350*660*1050 2000*860*1095 600

P-20 20 16 22 17.6 404A-22G1 PI144D 1350*660*1050 2000*860*1095 650

P-27 27 21.6 30 24 404D-22TG PI144F 1600*660*1050 2000*860*1095 680

P-30 30 24 33 26 1103A-33G PI144G 1800*760*1150 2200*1000*1250 1050

P-45 45 36 50 40 1103A-33TG1 PI144K 1900*760*1200 2300*1000*1250 1150

P-60 60 48 66 52.8 1103A-33TG2 UCI2245E 1900*760*1200 2300*1000*1200 1250

P-80 80 64 88 70 1104A-44TG2 UCI224G 2150*760*1250 2600*1000*1500 1400

P-100 100 80 110 88 1104C-44TAG2 UCI274C 2150*760*1250 2600*1000*1500 1450

P-150 150 120 165 132 1106A-70TAG2 UCI274F 2500*850*1400 2850*1000*1500 1600

P-180 180 144 198 158 1106A-70TAG3 UCI274F 2500*850*1400 2850*1000*1500 1800

P-200 200 160 220 176 1106A-70TAG4 UCI274H 2800*950*1400 3300*1200*1500 1890

P-225 225 180 248 198 1506A-E88TAG2 UCDI274J 3000*1050*1600 3700*1400*1900 2800

P-250 250 200 275 220 1506A-E88TAG3 UCDI274K 3000*1050*1600 3700*1400*1900 2850

P-275 275 220 303 242 1506A-E88TAG4 HCI444C 3000*1050*1600 3700*1400*1900 3050

P-300 300 240 330 264 1506A-E88TAG5 HCI444D 3000*1050*1600 3700*1400*1900 3150

P-350 350 280 385 308 2206C-E13TAG2 HCI444E 3300*1120*2000 4500*1650*2055 3750

P-400 400 320 440 352 2206C-E13TAG3 HCI444F 3300*1120*2000 4500*1650*2055 3900

P-450 450 360 495 396 2506C-E15TAG1 HCI544C 3500*1120*2050 5000*1800*2055 4200

P-500 500 400 550 440 2506C-E15TAG2 HCI544C 3500*1120*2050 5000*1800*2055 4500

P-600 600 480 660 528 2806C-E18TAG1A HCI544E 3500*1120*2050 5000*1800*2500 5000

P-650 650 520 700 560 2806A-E18TAG2 HCI544F 3500*1120*2050 5000*1800*2500 5500

P-750 750 600 825 660 4006-23TAG2A LVI634B 4100*1660*2200 5600*1900*2500 6800

P-800 800 640 880 704 4006-23TAG3A LVI634C 4100*1660*2200 5600*1900*2500 7000

P-900 900 720 990 792 4008TAG2A LVI634D 4900*1800*2500 6050*2435*2585 (20G) 9200

P-1000 1000 800 1100 880 4008TAG2A LVI634E 4900*1800*2500 6050*2435*2585 (20G) 9400

P-1250 1250 1000 1375 1100 4012-46TWG2A LVI634G 5000*2200*2550 12192*2435*2896 (40HQ) 11500

P-1500 1500 1200 1650 320 4012-46TAG2A PI734C 5000*2200*2550 12192*2435*2896 (40HQ) 11900

P-1800 1800 1440 1980 1584 4016TAG1A PI734E 6850*2250*2850 12192*2435*2896 (40HQ) 15000

P-2000 2000 1600 2200 1760 4016TAG2A PI734F 6850*2250*2850 12192*2435*2896 (40HQ) 15500

P-2250 2250 1800 2475 1980 4016-61TRG3 PI734G 6850*2250*2850 12192*2435*2896 (40HQ) 18000

400V / 50Hz / 1500RPM Perkins Diesel Engine Alternator Open type Soundproof type Genset

Prime Standby Packing (mm) Packing (mm) Weight

(L X W x H) (L X W x H) KG KVA KW KVA KWModel Brand Stamford

Model

50Hz

Notes:

- All ratings are for guidance only.

- All ratings data is based on operation under ISO 8528, ISO 3046, DIN6271 conditions using typical fan sizes and drive ratios. Performance tolerance quoted by PowerLink is +/-5%.

- Prime Power = Power at available load in lieu of main power netwoek. An overload of 10% permitted for one hour in every twelve hours of operation.

- Standby Power = Power available at a variable load in the event of a main power network failure, up to a maximum of 50 hours per year. No overload is permitted.

- Rated power factor: 0.80.

- The ATS is based on the following standards: three phase gensets (380-480V), single phase gensets (220-240V).

- Also available in the following voltages: 1P 220V/230V/240V: 3P 380V/220V, 400V/230V, 415V/240V, 440V/254V.

Page 8: DIESEL GENERATION AUSTRALIA GENERATOR PARTSdgaus.com.au/wp-content/uploads/2016/05/NEW DGA catalogue(1).pdf · DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA GENERATOR PARTS

DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA

Home backup power. Comfort. Security. Convenience.A permanently installed Generac home backup generator protects your home automatically. It runs on natural gas or liquid propane (LP) fuel, and sits outside just like a central air conditioning unit. A home backup generator delivers power directly to your home’s electrical system, backing up your entire home or just the most essential items

Page 9: DIESEL GENERATION AUSTRALIA GENERATOR PARTSdgaus.com.au/wp-content/uploads/2016/05/NEW DGA catalogue(1).pdf · DIESEL GENERATION AUSTRALIA DIESEL GENERATION AUSTRALIA GENERATOR PARTS

CONTACTS: Call: Richard 0407 919 474 Call: Hamish 0405 184 462

E m a i l : e n q u i r i e s @ d g a u s. co m . a u

w w w . d g a u s . c o m . a u

l Great Competitive Pricesl Cost Effective Solutionsl High Quality Productsl Expert Product Knowledge & Advice

l Full Warranty Minimum 1 Yearl Full Mobile Backup Service 7 daysl Tasmanian Owned & Operatedl Over 20 Years Industry Experience

Why Buy From DGA?

Call us today 03 6243 6666 to discuss your power needs