Diatron MI PLC Papírgyár u. 58-59. H-1038 Budapest, HUNGARY Phone: (36-1) 436 9800 Fax: (36-1) 436 9809 www.diatron.com Abacus Junior VET and Abacus Junior VET 5 Diatron reserv esthe rightto change anyof thespecicaons without prior noce. *Usageof original Diatron reagents is recommended.  Full specicaonsareavailable on requestor can beobtained from www.diatron.com (select ”products”.) Parameters Measuring principle Throughput Sample volume Sampling method Sample proles Reagents* Calibraon Quality control User interface User language Soware upgrade Data storage capacity Printout External keyboard Interfacing capabilies Operang mode Size (WxDxH) Weight Operang environment  Abacus Junior VET  Abacus Junior VET 5 18 parameters, including 3-part WBC dierenal: WBC, LYM, MID, GRA, LYM%, MID%, GRA%, RBC, HCT, MCV, RDW, HGB, MCH, MCHC, PLT, PCT, MPV, PDW Impedancemethod 22-28 tests/hour 25 μl of whole blood Open tube system with automac sample rotor Dog, Cat, Horse, Cale, Pig, Mouse, Rat, Rabbit, Ferret, Chimp, Sheep, Goat and user dened proles Isotonic Diluent, Lyse, Cleaner and Rinse Automac or manual 6 lots Easy-to-use, menu driven user interface with 6 soware buons (with icons), 6 hardware funcon buons, cursor and numeric keys Mullingual user interface USB 1000 (2000/10000 oponal) result, including histograms Built-in printer: Seiko “Easy Paper Operaon” thermal printel, 56 mm wide roll paper (oponal) PS/2, USB Serial port, USB Mul user mode 320 × 260 × 365 mm 12 kg Temperature: 15-35°C Relave humidity: max 80% (non-condensi ng) 22 parameters, including 5-part WBC dierenal: WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW, HGB, MCH, MCHC, PLT, PCT, MPV, PDW Impedancemethod 22-28 tests/hour in 3-part mode 15-20 test/hour in 5-part mode 25/50 μl of whole blood in 3/5-part mode Open tube system with automac sample rotor  – in 5-part mode: Dog, Cat, Horse, Contr ol blood  – in 3-part mode: Dog, Cat, H orse, Cale, Pi g, Mouse, Rat, Rabbit, Ferret, Chimp, Sheep, Goat, Guinea-pig and user dened proles Isotonic Diluent, Lyse, DiVET5, Cleaner and Rinse Automac or manual 6 lots Easy-to-use, menu driven user interface with 6 soware buons (with icons), 6 hardware funcon buons, cursor and numeric keys Mullingual user interface USB 1000 (2000/10000 oponal) result, including histograms Built-in printer: Seiko “Easy Paper Operaon” thermal printel, 56 mm wide roll paper (oponal) PS/2, USB Serial port, USB Mul user mode 320 × 260 × 365 mm 13 kg Temperature: 15-35°C Relave humidity: max 80% (non-condensing) Abacus Junior VET and Abacus Junior VET 5 Innovave Soluons in Hematology Your distributor: Technical Specicaons    A     b    a    c    u    s    J    u    n    i    o    r    V    E    T a n d  A b a u s J u n i o r V E     a    n     d    A     b    a    c    u    s    J    u    n    i    o    r    V    E    T    5 Type Name Code Pack Size Isotonic Diluent DiatroDil VET D1022 20 L Hemolysing Agent DiatroLyse VET D2041 1 L Hemolysing Agent Diatro DiVET5 D2051 1 L Cleaner Diatro Cleaner D5011 1 L Cleaner Diatro Cleaner D5015 5 L Rinse soluon Diatro Rinse VET D4011 1 L Rinse soluon Diatro Rinse VET D4015 5 L Reagent Pack Junior VET Reagent Pack DRP01 set Reagent Pack Junior VET 5 Reagent Pack DRP02 set We oer hematology systems of two interlocking components: analyzers and reagents. Diatron hematology analyzers show the best perfomance with the original reagents developed and made by Diatron. All our reagents are cyanide-free and have extended shelf life. Reagents

Diatron Abacus JuniorVet & Vet5

Embed Size (px)

Citation preview

Page 1: Diatron Abacus JuniorVet & Vet5

8/13/2019 Diatron Abacus JuniorVet & Vet5

http://slidepdf.com/reader/full/diatron-abacus-juniorvet-vet5 1/2

Diatron MI PLC

Papírgyár u. 58-59.

H-1038 Budapest, HUNGARY

Phone: (36-1) 436 9800

Fax: (36-1) 436 9809

www.diatron.com

Abacus Junior VET and Abacus Junior VET 5

Diatron reservesthe rightto change anyof thespecificaons without prior noce.

*Usageof original Diatron reagents is recommended.

 Full specificaonsareavailable on requestor can beobtained from

www.diatron.com (select ”products”.)

Parameters

Measuring principle

Throughput 

Sample volume

Sampling method 

Sample profiles

Reagents*

Calibraon

Quality control 

User interface

User language

Soware upgrade

Data storage capacity 

Printout 

External keyboard 

Interfacing capabilies

Operang mode

Size (WxDxH)

Weight 

Operang environment 

 Abacus Junior VET   Abacus Junior VET 5

18 parameters, including 3-part WBC differenal:

WBC, LYM, MID, GRA, LYM%, MID%, GRA%, RBC, HCT,

MCV, RDW, HGB, MCH, MCHC, PLT, PCT, MPV, PDW

Impedance method22-28 tests/hour

25 μl of whole blood

Open tube system with automac sample rotor

Dog, Cat, Horse, Cale, Pig, Mouse, Rat, Rabbit, Ferret,

Chimp, Sheep, Goat and user defined profiles

Isotonic Diluent, Lyse, Cleaner and Rinse

Automac or manual

6 lots

Easy-to-use, menu driven user interface with 6 soware

buons (with icons), 6 hardware funcon buons,

cursor and numeric keys

Mullingual user interface

USB

1000 (2000/10000 oponal) result, including histograms

Built-in printer: Seiko “Easy Paper Operaon” thermal

printel, 56 mm wide roll paper (oponal)

PS/2, USB

Serial port, USB

Mul user mode

320 × 260 × 365 mm

12 kg

Temperature: 15-35°C

Relave humidity: max 80% (non-condensing)

22 parameters, including 5-part WBC differenal:

WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%,

EOS%, BAS%, RBC, HCT, MCV, RDW, HGB, MCH, MCHC,

PLT, PCT, MPV, PDW

Impedance method22-28 tests/hour in 3-part mode

15-20 test/hour in 5-part mode

25/50 μl of whole blood in 3/5-part mode

Open tube system with automac sample rotor

 – in 5-part mode: Dog, Cat, Horse, Control blood

 – in 3-part mode: Dog, Cat, Horse, Cale, Pig, Mouse,

Rat, Rabbit, Ferret, Chimp, Sheep, Goat, Guinea-pig

and user defined profiles

Isotonic Diluent, Lyse, Diff VET5, Cleaner and Rinse

Automac or manual

6 lots

Easy-to-use, menu driven user interface with 6 soware

buons (with icons), 6 hardware funcon buons,

cursor and numeric keys

Mullingual user interface

USB

1000 (2000/10000 oponal) result, including histograms

Built-in printer: Seiko “Easy Paper Operaon” thermal

printel, 56 mm wide roll paper (oponal)

PS/2, USB

Serial port, USB

Mul user mode

320 × 260 × 365 mm

13 kg

Temperature: 15-35°C

Relave humidity: max 80% (non-condensing)

Abacus Junior VET and Abacus Junior VET 5

Innovave Soluons in HematologyYour distributor:

Technical Specificaons

   A    b   a   c   u

   s   J   u   n   i   o   r   V   E   T

and AbausJuniorVE 

   a   n    d   A

    b   a   c   u   s   J   u

   n   i   o   r   V   E

   T   5

Type Name Code Pack Size

Isotonic Diluent DiatroDil VET D1022 20 L

Hemolysing Agent DiatroLyse VET D2041 1 L

Hemolysing Agent Diatro Diff VET5 D2051 1 L

Cleaner Diatro Cleaner D5011 1 L

Cleaner Diatro Cleaner D5015 5 LRinse soluon Diatro Rinse VET D4011 1 L

Rinse soluon Diatro Rinse VET D4015 5 L

Reagent Pack Junior VET Reagent Pack DRP01 set

Reagent Pack Junior VET 5 Reagent Pack DRP02 set

We offer hematology systems of two

interlocking components: analyzers

and reagents. Diatron hematology

analyzers show the best perfomancewith the original reagents

developed and made by Diatron.

All our reagents are cyanide-free

and have extended shelf life.

Reagents

Page 2: Diatron Abacus JuniorVet & Vet5

8/13/2019 Diatron Abacus JuniorVet & Vet5

http://slidepdf.com/reader/full/diatron-abacus-juniorvet-vet5 2/2

Abacus Junior VET and Abacus Junior VET 5

Ease of use

• The user-friendly interface enables fast and effi cient work

• The large back-lit LCD allows accurate paent data entry

and monitoring of results and histograms

• 6 level QC, L-J graphs and self diagnosc funcons let you monitorreliability and accuracy

• The instrument features a logically constructed mullingual

operang menu

• New features can be easily introduced by simple soware upgrades

• Paent data can easily be saved in the database or using a pen-

or disk drive

• Both models can interface to your laboratory computer for further

processing of the measured data. Results can also be retrieved on

the built-in roll paper printer or on an external printer

Abacus Junior vet and

 Abacus Junior vet

High performance

• Complete Hematology

profiles for a wide range of

species

• Abacus junior VET provides

18-parameter,  while

Abacus junior VET 5

a 22-parameter 

hematology results.

• Abacus junior VET offers

pre-defined 3-part diff.

profiles for dog, cat, horse,

cale, pig, mouse, rat,

rabbit, ferret, chimp,

sheep and goat.

In addion, Abacus junior

VET 5 offers 5 part diff.

results for dog, cat,

horse and cale. Both instruments allow

user defined profiles

in 3-part mode.

Reliable and effi cient 

• Abacus Junior VET and Abacus Junior VET 5 are almost

maintenance f ree resulng in minimal disrupon

of operaon

• Diatron Vet analyzers are small and light. Their compact

size makes the instruments ideal for use in veterinary

pracces requiring minimum desktop space

• Precise and reliable 3-part and 5-part veterinary

hematology profiles are guaranteed even in the most

demanding clinical environment by ulizing industry

standard electronic and mechanic components

5Abacus Junior VET and Abacus Junior

VET 5 offer an opmal soluon

for veterinary clinics and pracces,

which require high quality 3-part

or 5-part WBC diff erenal results.