136
Product Data Sheet 00813-0100-4760, DS-4009 Flow-375 Diamond II+ Annubar® Diamond II+Annubar ® Primary Flow Element THE DIAMOND II+ANNUBAR ® PRIMARY FLOW ELEMENT HAS PROVEN TO BE ACCURATE AND RELIABLE IN HUNDREDS OF THOUSANDS OF APPLICATIONS. ACCURATE Annubar primary flow element design Long-term accuracy SENSIBLE Energy cost savings Low installation costs ADAPTABLE No system shutdown Special materials Gear drive Special flow element models and designs Pak–Lok ® Elbow mounting Bi-directional flows Integral manifold head Integral valve head Integral temperature sensor COMPLETE POINT SOLUTIONS Complete Point Solutions provides fully engineered measurement solutions, combining best product and practices for improved performance, reliability, and cost of ownership. The capability of the world’s finest industrial measurement instrumentation is further increased by combining it with a premier offering of complimentary products. This system is engineered and assembled by Rosemount Inc. to make it easy for you to specify and order the correct equipment for your process measurement needs. We complement our field instruments with a wide range of technologies; including, manifolds, primary elements, process flanges and seals, and temperature sensors and accessories. Complete Point Solutions is designed to provide you with Best-in-Class equipment — allowing you to save on installation costs, and improve the reliability and capability of your process. Take advantage of our vast experience in process measurement, and start improving your process with Complete Point Solutions.

Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Embed Size (px)

Citation preview

Page 1: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Product Data Sheet 00813-0100-4760, DS-4009

Flow-375

Diam

ond

II+An

nuba

Diamond II+Annubar ® Primary Flow Element

THE DIAMOND II+ANNUBAR ® PRIMARYFLOW ELEMENT HAS PROVEN TO BEACCURATE AND RELIABLE IN HUNDREDSOF THOUSANDS OF APPLICATIONS.

ACCURATE

• Annubar primary flow element design

• Long-term accuracy

SENSIBLE

• Energy cost savings

• Low installation costs

ADAPTABLE

• No system shutdown

• Special materials

• Gear drive

• Special flow element models and designs

• Pak–Lok®

• Elbow mounting

• Bi-directional flows

• Integral manifold head

• Integral valve head

• Integral temperature sensor

COMPLETE POINT SOLUTIONS™

Complete Point Solutions provides fully engineered measurement solutions, combining best product and practices for improved performance, reliability, and cost of ownership.

The capability of the world’s finest industrial measurement instrumentation is further increased by combining it with a premier offering of complimentary products. This system is engineered and assembled by Rosemount Inc. to make it easy for you to specify and order the correct equipment for your process measurement needs.

We complement our field instruments with a wide range of technologies; including, manifolds, primary elements, process flanges and seals, and temperature sensors and accessories.

Complete Point Solutions is designed to provide you with Best-in-Class equipment — allowing you to save on installation costs, and improve the reliability and capability of your process.

Take advantage of our vast experience in process measurement, and start improving your process with Complete Point Solutions.

Page 2: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-376

Diamond II+ Annubar®

Diamond

II+Annubar®

D i a m o n d I I + A n n u b a rP r i m a r y F l o w E l e m e n t

DIAMOND II+ ANNUBAR PRIMARY FLOW ELEMENT - - - - - 379DRAMATICALLY REDUCEINSTALLATION AND

OPERATINGCOSTS - - - - - - - - - - - - - - - - - - - - - - - - - - - 379MOUNTING CONFIGURATIONS- - - - - - - - - - - - - - - - - - - - 379

Design Pr incip les

DIFFERENTIAL PRESSUREFLOW MEASUREMENT - - - - - - - - - - - - - - - - - - - - - - - - - 380HOW IT WORKS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 380

Per formance

THE DIAMOND II+ SENSOR- - - - - - - - - - - - - - - - - - - - - - 382

Benef i ts

ENERGY SAVINGS - - - - - - - - - - - - - - - - - - - - - - - - - - - - 384OPERATINGCOST SAVINGS- - - - - - - - - - - - - - - - - - - - - - 384INSTALLATION COST SAVINGS - - - - - - - - - - - - - - - - - - - 384ELBOW-MOUNTED ANNUBARPRIMARY FLOW ELEMENT - - - - - - - - - - - - - - - - - - - - - - 385

Features

DESIGNED-IN ACCURACY - - - - - - - - - - - - - - - - - - - - - - - 386ENERGY COST SAVINGS - - - - - - - - - - - - - - - - - - - - - - - - 386INSTALLATION COST SAVINGS - - - - - - - - - - - - - - - - - - - 386CHOOSE THEMODELADAPTED FOR YOUR APPLICATION - - - - - - - - - - - - - - - - 386SPECIAL MODELS AND DESIGNS - - - - - - - - - - - - - - - - - - 387

Ins tal lat ion

ORIENTATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 388LOCATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 388

Siz ing and How To Order

1. CHOOSE AMOUNTING METHOD- - - - - - - - - - - - - - - - - 3892. CHOOSE ASENSORSIZE - - - - - - - - - - - - - - - - - - - - - - 3903. VERIFY MODEL AND SENSORSIZE - - - - - - - - - - - - - - - 3914. CHOOSE THEMODEL OPTIONS- - - - - - - - - - - - - - - - - - 3935. VERIFY PROCESS ANDPIPE INFORMATION - - - - - - - - - - 394

Ordering In format ion—Model DCR

MODEL DCR+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - 395MODEL DCR+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - 397MODEL DCR+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - 400MODEL DCR+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - 403

Page 3: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Flow-377

Diam

ond

II+An

nuba

D i a m o n d I I + A n n u b a rP r i m a r y F l o w E l e m e n t

Ordering In format ion—Model DFF

MODEL DFF+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - -409MODEL DFF+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - -411MODEL DFF+25H/26H - - - - - - - - - - - - - - - - - - - - - - - - 414MODEL DFF+25M/26M - - - - - - - - - - - - - - - - - - - - - - - - 417MODEL DFF+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - -420MODEL DFF+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - -423MODEL DFF+45H/46H - - - - - - - - - - - - - - - - - - - - - - - - 426MODEL DFF+45M/46M - - - - - - - - - - - - - - - - - - - - - - - - 428

Ordering In format ion—Model DPF

MODELS DPF+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - 434MODELS DPF+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - 436MODELS DPF+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - 438MODELS DPF+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - 440

Ordering In format ion—Model DNT

MODEL DNT+10S- - - - - - - - - - - - - - - - - - - - - - - - - - - - 446

Ordering In format ion—Model DNF

MODEL DNF+10S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 447MODEL DNF+10H - - - - - - - - - - - - - - - - - - - - - - - - - - -449MODEL DNF+10M - - - - - - - - - - - - - - - - - - - - - - - - - - -450

Ordering In format ion—Model DNW

MODEL DNW+10S - - - - - - - - - - - - - - - - - - - - - - - - - - -451

Ordering In format ion—Model DMT

MODEL DMT+15S - - - - - - - - - - - - - - - - - - - - - - - - - - -456MODEL DMT+25S - - - - - - - - - - - - - - - - - - - - - - - - - - -458MODEL DMT+35S - - - - - - - - - - - - - - - - - - - - - - - - - - -461

Ordering In format ion—Model DHT

MODEL DHT+15S- - - - - - - - - - - - - - - - - - - - - - - - - - - - 469MODEL DHT+25S- - - - - - - - - - - - - - - - - - - - - - - - - - - - 471MODEL DHT+35S- - - - - - - - - - - - - - - - - - - - - - - - - - - - 474

Ordering In format ion—Model DHF

MODEL DHF+15S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 482MODEL DHF+25S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 485MODEL DHF+25H - - - - - - - - - - - - - - - - - - - - - - - - - - -488MODEL DHF + 25M - - - - - - - - - - - - - - - - - - - - - - - - - - 491MODEL DHF+35S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 494MODEL DHF+45S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 497MODEL DHF+45H - - - - - - - - - - - - - - - - - - - - - - - - - - -500

Spec i f icat ions

FUNCTIONAL SPECIFICATIONS- - - - - - - - - - - - - - - - - - - -509PERFORMANCESPECIFICATIONS- - - - - - - - - - - - - - - - - - - 509PHYSICAL SPECIFICATIONS- - - - - - - - - - - - - - - - - - - - - - 510

Page 4: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-378

Diamond II+ Annubar®

Diamond

II+Annubar®

Page 5: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

D i a m o n d I I +

A N N U B A R ®

P r i m a r y F l o wE l e m e n t

-379

Diam

ond

II+An

nuba

Flow

DIAMOND II+ANNUBARPRIMARY FLOW ELEMENT

The Annubar® primary flow element has proven to be accurate and reliable in hundreds of thousands of applications. The Diamond II+ Annubar primary flow element is designed to give the highest performance of any differential pressure device.

The flow element operates by sensing an impact pressure and a reference pressure through multiple sensing ports connected to dual averaging plenums. The resultant difference is a differential pressure signal.

Sensing ports are located on both the up and downstream sides of the flow element. The number of ports is proportional to the pipe diameter.

FIGURE 1. Shape Cross-Sections.

DRAMATICALLY REDUCEINSTALLATION ANDOPERATING COSTSThe Annubar primary flow element is inherently easy and inexpensive to install. The small size of the hole required and the minimal welding keep installation costs low.

The primary flow element offers little restriction to flow which, in turn, minimizes pressure drop. The resulting energy and cost savings can positively impact your operating cost.

MOUNTINGCONFIGURATIONS

Fl o-Tap ÿallows installation without system shutdown.

Pak- Lok ÿmounts safely through a weld coupling and packing gland.

Fl anged for high pressure applications.

St reamli ne for large pipes and high velocity.

p

Diamond II+Shape

Streamline Shape

Page 6: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-380

Diamond II+ Annubar®

Diamond

II+Annubar®

Design Principles

DIFFERENTIAL PRESSUREFLOW MEASUREMENT

Flow devices producing a differential pressure signal—called DP devices—have a reputation for accuracy, simplicity, and reliability. The traditional DP devices—orifice plate, venturi tube and flow nozzle, while meeting the above criteria—are expensive to install, limited in application, and most are not energy efficient.

The Diamond II+ sensor is a multiple-tube, rigid structure that provides dual averaging chambers with a diamond-shaped cross section (Figure 2) and bi-directional flow sensing..

FIGURE 2. Diamond II+ Sensor Design.

HOW IT WORKS

The Annubar primary flow element produces a DP signal proportional to the square of the flow rate in accordance with Bernoulli’s theorem. The DP signal has two components: the high pressure (PH) and the low pressure (PL) (Figure 3).

FIGURE 3. PH(avg.) – PL(avg.) = DP (hw).

High Pressure Averaging

The PH is produced by impact or stagnation of the moving fluid on the sensor. The velocity profile results in a corresponding stagnation pressure profile. Multiple sensing ports, located on the front of the sensor, sense the impact pressure profile.

Inside the high pressure chamber, the average velocity pressure is maintained by the proportionality of the sensing port diameters to the chamber cross-sectional area.

Low Pressure AveragingAs the fluid continues around the sensor, it generates a vortex shedding pattern and creates a PL profile. The PL is used as a pressure reference so the velocity can be determined independent of pipe static pressure. The PL is sensed by ports, located downstream and opposite the high pressure ports. Working on the same principle as the PH side, an average PL is maintained in the low pressure chamber. This assures less dependence on the magnitude of flow or Reynolds Number.

40%

60%

Impact Pressure

Pipe StaticPressure

LowPressureSignal

HighPressureSignal

HIGH LOWPH (avg.) PL (avg.)

FLOWVelocityProfile

PH – PL = DP

Blockage andSuction Pressure

Page 7: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Sensing Ports vs. Pipe Size

Flow laboratory tests have shown that larger pipes are more susceptible to dynamic distortions of the velocity profiles. These dynamic distortions can affect the stability and accuracy of the flow device.

The Diamond II+ design is engineered so that the number of sensing ports is a function of the pipe size (Figure 4).

The additional sensing ports provide a larger sample of the velocity profile, giving a better average of the velocity profile.

TABLE 1. Sensing Ports vs. Pipe Size.

FIGURE 4. Sensing Ports.

Diamond-Shaped Sensors—the Key to Accuracy

The diamond shape establishes a fixed separation point of the fluid from the sensor (Figure 5). The fixed separation point reduces changes in the low, (or reference pressure), that would cause a corresponding loss of accuracy in flow measurement.

Round SensorsRound sensors have a variable separation point of the fluid from the sensor (Figure 5). The separation point varies with fluid type, velocity, surface roughness of the sensor, and turbulence. Sensing ports placed at angles greater than 30° from the front of a round sensor will generate a reference or low pressure signal that is unpredictable—with errors as high as 10%.

FIGURE 5. Fixed vs. Variable Separation Point.

Pipe Size Number of Ports Port Location

2 in. to 5 in. 4 Per ChebyshevCalculus foraveraging6 in. to 14 in. 6

16 in. to 72in.

8 or more

½–2 in. 5 in.24 in.

42 in.

72 in.

10 15/1625/26

35/36

45/46

FixedSeparation Point

Variable Separation Point

Flow-381

Page 8: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-3

Diamond II+ Annubar®

Diamond

II+Annubar®

Sensor size: 10 Line size: 6 Sch 40 Bar # 100000pFluid: WaterPublished K: 0.6392 Date: 10/13/97

Performance

THE DIAMOND II+ SENSOR

Independent flow laboratories have tested and proven the Diamond II+ Annubar primary flow element’s accuracy. Calibration results for water flow at Alden (Alden Research Laboratory, Alden, Massachusetts), NEL (National Engineering Laboratory, Scotland), and gases at CEESI (Colorado Engineering Experimental Station Inc., Nunn, Colorado) show conclusively that the Diamond II+ design improves performance and rangeability compared to traditional DP devices.

Accuracy: ±1% is maintained over a flow turndown of 30:1, depending on the application

Repeatability: ±0.1%

The Diamond II+ SensorExtensive Testing—High Accuracy

Any DP device is only as accurate as its ability to repeat and maintain its flow coefficient (reproducing the same coefficient within a respectable tolerance for different fluids and piping systems). Dieterich Standard, Inc. has completed extensive independent flow laboratory tests in a wide range of pipe sizes and fluids. Typical test results on liquids and highly turbulent gas flows are shown below:

FIGURE 6. Dieterich Standard, Inc. Laboratory.

FIGURE 7. CEESI Laboratory.

82

Page 9: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Round Sensors

The simplest design for an averaging pitot is a round cylinder. However, as the Reynolds number or flow rate increases, accuracy deteriorates because the separation point of the fluid varies as it passes around the cylinder. This causes a deviation between actual and predicted performance and occurs regardless of the number or location of the sensing ports. Additionally, the level of pipeline turbulence affects the separation point, which makes the deviation impossible to predict.

FIGURE 8. Round Sensors Test Data.

Annubar Primary Flow ElementLong–Term Accuracy

Annubar primary flow element’s flow coefficient remains stable over the long term and is unaffected by wear and dirt or grease buildup.

Annubar Primary Flow Element vs. OrificeAny drift in the flow coefficient (K) results in reduced accuracy. A 10% shift in the K factor results in a 10% error in flow reading.

The orifice long–term accuracy is significantly affected by warping, wear, and dirt or grease buildup.

FIGURE 9. Comparison of Long Term Accuracy: AnnubarPrimary Flow Element vs. Orifice.

Round sensor test results—variable turbulence levels

6" sch. 40 straight pipe –Butterfly valve–20 dia.

Dirt—11%

Damage or Nicks—15%Misalignment—3%

WeldingIcicles orSedimentBuildup—

11%

Independent tests by Florida Gas Transmission Company.

Lubricant—24% Warp—9% Wear—0.050-13%

Flow-383

Page 10: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-3

Diamond II+ Annubar®

Diamond

II+Annubar®

Benefits

ENERGY SAVINGS

The non-constricting design of the Annubar diamond-shaped sensor produces the lowest permanent pressure loss of all primary flow sensors. The non-constricting design also results in significant power savings. An orifice plate typically consumes more than 100 times the energy of an Annubar primary flow element plate.

FIGURE 10. The Annubar Plate vs. the Orifice Plate.

OPERATING COST SAVINGSCompare the orifice and Annubar operating costs. Annubar primary flow element is 100 times more efficient and can offer energy savings of $700 per year per measurement point on liquids, and $30,000 per year savings on gases and steam.

FIGURE 11. Operating Cost Savings.

INSTALLATION COST SAVINGS

Compared to any other primary flow element, Annubar primary flow element has the lowest installation cost.

Annubar vs. Orifice Installation CostsOn an 8 inch (203 mm) pipe, an Annubar primary flow element requires only 4 linear inches (101 mm) of welding. An orifice plate installed in the same pipe requires 50 linear inches (1270 mm) of welding (Figure 13). Annubar primary flow element’s reduced welding requirement saves over ten installation man-hours.

FIGURE 12. Installation Cost Savings.

FIGURE 13. Welding Distances.

Annubar

Orifice

β= 0.6

Actualpressure

loss(inches

ofw.c.)

Act

ualD

.P.p

rodu

ced

(inch

esof

w.c

.)

4 Linear InchesWelding (8 ″pipe)

50 Linear InchesWelding (8 ″pipe)

Annubar primary flow element saves on installation costs—up to 10man-hours less than orifice plate.

84

Page 11: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

ELBOW-MOUNTED ANNUBARPRIMARY FLOW ELEMENT

Although a pipe elbow distorts fully developed flow, it also acts as a flow conditioner, which results in a predictable flow profile immediately downstream of the discharge of the elbow (Figure 14).

When an Annubar primary flow element is installed two pipe diameters downstream of the centerline of the elbow (Figure 15), it will average the velocity profile and provide repeatable, predictable results. The key to accuracy is the prediction of the discharge coefficient, or K-value, in this elbow position.

Dieterich Standard, Inc. has done testing and evaluation to predict this coefficient to within ±3%.

FIGURE 14. Flow Profiles Downstream of an Elbow.

FIGURE 15. Annubar Elbow Installation.

Dieterich Standard, Inc. can also perform the flow calculation for you and provide a computer printout. To do so, specify EO (outside mount) or EI (inside mount), along with the model callout and flow conditions.

FIGURE 16. Annubar Installation Recommendations.

InstallationThe piping requirements for a ±3% accuracy installation will vary based on the piping configuration ahead of the elbow.To be consistent with straight-run requirement charts, see the piping configurations in Figure 17. The upstream straight-run requirements (L1) and the downstream diameters (L2) are in terms of pipe inside diameters (D).

Requirements for Successful Installation• The elbow must have a short radius and be

welded or flanged rather than threaded.• Refer to piping configurations below to verify

minimum diameters available.• Mount the Diamond II+ two pipe inside

diameters from the center of upstream pipe, and in-plane with the elbow (see Figure 16). Either inside or outside radius mounting will work, but the outside radius is preferred, as this allows the higher velocity vectors to be at the support point.

FIGURE 17. Elbow–Mount Annubar PrimaryFlow Element Piping Configurations.

Diamond II+ Annubar primary flow element DCR shown

Non-Swirl Producing Swirl Producing

PipingConfigurations

Min. Req.Values

PipingConfigurations Min. Req. Values

L1 L2 L1 L1 L2

3 2

WithoutConditioner: 4

WithConditioner: N/A

2

4 2

WithoutConditioner: 10

WithConditioner: 5

2

5 2

Valve UseWithoutConditionerFull Open: 3Control: 14

With ConditionerFull Open: 3Control: 10

2

Valve Use Valve Use

Full Open:3

Control:10

2

WithoutConditionerFull Open: 5Control: 16

With ConditionerFull Open: 5Control: 12

2

Valve Use

Full Open:5

Control:12

2

Flow-385

Page 12: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-3

Diamond II+ Annubar®

Diamond

II+Annubar®

Features

DESIGNED-IN ACCURACY

The Diamond Shape is Key

The diamond shape establishes a fixed separation point of the fluid from the sensor (Figure 18). The fixed separation point reduces changes in the low, or reference pressure that would cause a corresponding loss of accuracy in flow measurement. Round sensors have a variable separation point causing an unpredictable reference pressure, and can result in flow measurement errors as high as 10%. See “Design Principles” on page 380.

FIGURE 18. Fixed vs. Variable Separation Point.

Long–Term Accuracy

Dieterich Standard, Inc. has completed extensive independent flow laboratory tests in a wide range of pipe sizes and fluids that consistently demonstrates Annubar primary flow element’s superior ability to repeat and maintain its flow coefficient. A DP device is only as accurate as its ability to do just that. See “Performance” on page 382.

• Alden Research Laboratory

• NEL, National Engineering Laboratory

• CEESI, Colorado Engineering Experimental Station, Inc.

ENERGY COST SAVINGS

The non-constricting design of Annubar primary flow element’s diamond-shaped sensor produces the lowest permanent pressure loss of all primary flow sensors. The low permanent pressure loss results in significant power savings. See “Annubar vs. Orifice Installation Costs” on page 384.

FIGURE 19. Low Permanent Pressure Loss.

INSTALLATION COST SAVINGS

Compared to any other primary flow element, Annubar primary flow element has the lowest installation cost. Savings range from 25% on smaller pipes to 70% on larger pipes. See “Operating Cost Savings” on page 384.

CHOOSE THE MODELADAPTED FOR YOUR APPLICATION

FIGURE 20. Three Model Options.

No System ShutdownAnnubar primary flow element is perfectly suited to retrofit applications because the Flo–Tap models can be hot–tapped without interruption of the flow—that is, without system shutdown. Three Flo–Tap models are available to meet your pressure requirements. See the Specification pages at the end of this section.

FIGURE 21. Flo-Tap: No System Shutdown.

Special MaterialsAnnubar primary flow elements are manufactured from stainless steel or other special materials to meet difficult applications for any industry. Special materials include Kynar® (PVDF), Monel®, Hastelloy®–C, Incoloy® 800 H, and HR 160.

Variable Separation Point

Fixed Separation Point

Round Sensor

Diamond II+ AnnubarPrimary Flow Element

Model Model ModelDHFDHTDMT

150# ANSIEquivalentThreadedAssy

600# ANSI EquivalentThreaded Assy

600# ANSIEquivalentFlangedAssy

Drill ThroughValve

Install

Inserted

86

Page 13: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Optional Worm Gear Drive

An optional worm gear drive (Figure 22) saves time because of a Single Point Drive system. The Single Point Drive system enables an Annubar primary flow element to be inserted in a 30 inch (762 mm) pipe in only five minutes. The gear can be powered in one of the following three ways:

• Hand crank

• Heavy duty electric drill

• Remote activated drive

FIGURE 22. Worm Gear Drive.

SPECIAL MODELS AND DESIGNS

A special Annubar sensor, MSL, handles high velocity, high temperature, and high pressure flows (up to 1015 °F/546 °C @ 2600 psig/17926 kPa). These conditions are typical in a Main Steam Line from a major power plant.

Annubar primary flow element systems have been designed for Continuous Emission Rate Monitoring (CERM) applications on large diameter stacks. These systems meet U.S. EPA 40CFR75 requirements such as purging and automatic daily calibration checks. DSF models are available for complete spanning of the diameter of the stack. For stacks exceeding 20 foot (6 meter) diameters, array models extending part way into the stack are available.

Pak-Lok Mounting HardwareSafety is the key to the Dieterich Standard, Inc. patented Pak–Lok mounting (Figure 23). Pak–Lok mounting seals and retains the sensor firmly against the inside opposite wall simply and without high torque requirements. Unlike a ferrule-mounted sensor, a Pak-Lok-mounted Annubar primary flow element can be installed and removed easily.

FIGURE 23. Pak-Lok Mounting.

Elbow-Mounted AnnubarPrimary Flow Element

Insufficient straight run is common in today's piping, but Annubar primary flow element averages the flow profile so it can provide accurate, repeatable flow measurement when installed two diameters downstream of a 90° elbow.

Bi–Directional FlowsThe symmetrical design, along with the controlled separation point provided by the exclusive diamond-shaped sensor, means that a single Annubar primary flow element is all that is required for bi-directional flow measurement.

Integral Manifold HeadThe integral manifold head provides a three valve manifold built-in to the Annubar sensor (Figure 24). Mount a DP transmitter to the Annubar sensor and simplify installation.

FIGURE 24. Integral Manifold Head.

Integral Valve HeadThe integral valve head features a compact design that requires fewer tubing connections (Figure 25). This means a more reliable, leak-free installation. Maintenance is also easier because seats can be replaced without disassembling tubing. Integral valve heads are not recommended on Flo–Taps above 400 °F (204 °C) or for steam applications.

FIGURE 25. Integral Valve Head.

Integral Temperature SensorSelected Annubar primary flow element models are available with a “built-in” temperature sensor (Figure 26). This feature eliminates an additional pipe connection and thermowell.

FIGURE 26. Integral Temperature Sensor.

Pak–Lok Nut

Packing Follower

Packing RingsWeldedLock Ring

Welded Fitting

O–Ring Groove

½ in.—14 NPT

Flow-387

Page 14: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-3

Diamond II+ Annubar®

Diamond

II+Annubar®

Installation

ORIENTATION

Note: Other orientations are possible with additional considerations.

Horizontal Pipes

FIGURE 27. Liquids and Steam.

FIGURE 28. Gases.

Vertical Pipes

FIGURE 29. Liquids and Gases.

FIGURE 30. Steam.

LOCATION

Recommended Approachand Depart Values

Selecting correct mounting locations for the Annubar primary flow element in the pipeline is important because disturbance in flow produced by pipe layout may affect the accuracy of measurement.

Straight Run Requirements

Use of recommended straight pipe lengths of uniform diameter upstream and downstream ensures that flow measurement will be made in flow with fully developed characteristics.

The following chart describes the minimum number of pipe diameters upstream and downstream of the Annubar. Longer lengths are always preferred (if available) for accurate flow measurement.

Note: Straight runs listed below are for water. Multiply times 1.5 for gases.

FIGURE 31. Installation Hole Sizes.

50° 50°

80° (Recommended zone)

30° 30°

120°(Recommended

zone)

Flow

360°

Upstream Dimensions

MinimumDiameters ofStraight Pipe

Without Vanes With Vanes DownstreamDimension

B

InPlane

A

Outof

Plane A

A’ C C’

8 1048 4 4

11 1648 4 4

23 2848 4 4

12 1248 4 4

18 1848 4 4

30 3048 4 4

Installationhole sizes 15 16 25 26 35 36 45 4

88

Page 15: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Sizing and How To Order

1. CHOOSE A MOUNTING METHOD

Line sizes 2 inches and larger

DCR

FIGURE 32. Regular ThreadedPak–Lok Assembly.

Mounting Method: Threaded Pak–Lok.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).

DFF

FIGURE 33. Flanged.

Mounting Method: Flanged.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).

DPF

FIGURE 34. Flanged Pak–Lok.

Mounting Method: Flanged Pak–Lok.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).

Line sizes ½ in. to 2 in.

DNT

FIGURE 35. Threaded In–Line.

Mounting Method: Male threaded.Pipe Sizes: 0.5 in. to 2 in. (25 mm to 50 mm).

DNF

FIGURE 36. Flanged In–Line.

Mounting Method: Flanged and gasket.Pipe Sizes: 0.5 in. to 2 in. (25 mm to 50 mm).

DNW

FIGURE 37. Welded In–Line.

Mounting Method: Welded in-line.Welded Pipe Sizes: 0.5 in. to 2 in. (25 mm to 50 mm).

Flo-Tap Model 8

DMT

FIGURE 38. Medium PressureThreaded Flo–Tap.

Mounting Method: Threaded Flo–Tap for pressure equivalent to ANSI Class 150 Flanges.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).

DHT

FIGURE 39. High PressureThreaded Flo–Tap.

Mounting Method: Threaded Flo–Tap for pressure equivalent to ANSI Class 600 Flanges.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).

DHF

FIGURE 40. High PressureFlanged Flo–Tap.

Mounting Method: Flanged Flo–Tap for pressure equivalent to ANSI Class 600 Flanges.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).

Flow-389

Page 16: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diamond II+ Annubar®

Flow-3

Diamond

II+Annubar®

2. CHOOSE A SENSOR SIZE

There are four Annubar primary flow element sensor sizes to choose from. The following table is a guideline to help select the correct the sensor.

TABLE 2. Sensor Size.

Using the smallest applicable sensor for a given line size is recommended. Use larger sensors where structural integrity requires it. A complete calculation, including structural analysis, is completed for every application using the Instrument Toolkit and/or Merlin software packages. Sensor 25/26 is preferred to sensor 15/16 in the 4-inch and 5-inch lines because the recommended product including integral transmitter mounting and integral RTD are unavailable in sensor 15/16.

Calculate Approximate Differential Pressure (hw)

Use fluid parameters at maximum flow rate. To calculate the differential pressure, use the equations below, the Dieterich Standard, Inc. Annubar primary flow element sizing program, or the Annubar Primary Flow Element Handbook.

Sensor Size Line Sizes

15/16 2 in. to 5 in.

25/26 4 in. to 42 in.

35/36 8 in. to 72 in.

45/46 10 in. to 72 in.

Equations to Calculate Differential Pressure

Liquid, gas & steam (mass rate of flow)

Liquid (volume rate of flow)

Gas (standard volumetric flow)

Gas (actual volume rate of flow)

hw1ρf-----

lbm hr⁄

358.94KD2-------------------------------

2=

ÿ ÿ= differential pressure, inches of water @ 68°F

K = flow coefficient

D= internal pipe diameter, inches

lbm / hr = pounds mass per hour

GPM = U.S. gallons per minute

ACFH = Actual cubic feet per hour

SCFH = Standard cubic feet per hour (@ 14.73 psia and 60° F)

ρf = flowing density, lbm / ft3 for gas:

.076487 lbm / ft3= Air density at 14.73 psia and 60°F.

Gf = Specific gravity of liquid

G = Specific gravity of gas (molecular weight of air = 28.9644)

Tf = Temperature of flowing gas in degrees Rankin (°R = °F + 460)

ρf = Flowing pressure, psia

K = 0.6 for approximate sizing

Pf14.73---------- 520

Tf------- 0.076487G××

hw Gf( ) GPM( )

5.666KD2( )--------------------------------

2=

hwTfG

Pf---------- SCFH

7 711KD2,-----------------------------

2=

hw ρf( ) ACFH

358.94KD2-------------------------------

2=

90

Page 17: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

3. VERIFY MODEL AND SENSOR SIZE

Compare maximum allowable flow to your maximum flow rates.

HW= maximum differential pressure in inches of water column Structural limits apply to 200°F and below.

SCFM = maximum air flow in standard cubic feet per minute For applications requiring higher values, consult factory

GPM = maximum water flow in gallons per minute 1.2 in. to 24 in. Sch 40

At standard conditions: air: 60°F at 14.73 psia 30 in. to 42 in. Sch Std.

water: 60°F, specific gravity 1.0, viscosity 1.12 centipoise 48 in. to 72 in. Actual Id

† During insertion and retraction of Flo–Tap sensors, flow rate must be reduced to give lower DP values equal to the DP limits of DFF models of the same sensor size.

Nom.Pipe

Size (ininches)

Sensor 10

DNT DNF DNW

SCFM HW GPM SCFM HW GPM SCFM HW GPM

.5 180.52 1500 50.943 180.52 1500 50.943 180.52 1500 50.943

.75 307.79 1500 89.404 307.79 1500 89.404 307.79 1500 89.404

1 498.82 1500 144.9 498.82 1500 144.9 498.82 1500 144.9

1.25 765.68 1180 222.41 765.68 1180 222.41 765.68 1180 222.41

1.5 902.04 884 262.02 902.04 884 262.02 902.04 884 262.02

2 1174.9 552 341.28 1174.9 552 341.28 1174.9 552 341.28

Sensor 15 Sensor 16

DCR DFF DHF† DPF DMT†/DHT† DCR DFF

SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM

2 1236.1 611 359.05 502.91 84.3 133.37 1555 967 451.7 1132.3 494 322.85 1324.9 702 384.87 1236.1 611 359.05 1322 699 384.04

2.5 1531.9 451 440.14 639.74 66.9 169.52 1886.4 699 547.95 1396 360 393.23 1623.9 518 471.7 1531.9 451 440.14 1641 529 476.68

3 2010.5 314 567.07 859.71 50.5 227.41 2408.7 478 699.65 1810.1 246 501.92 2127.9 360 607.18 2010.5 314 567.07 2175.3 380 623.82

3.5 2408.7 246 671.26 1046.1 41.7 276.37 2852.6 369 822.13 2158.9 192 593.03 2554 282 718.7 2408.7 246 671.26 2639.5 305 747.44

4 2816 199 777.38 1237.1 35.1 326.46 3331.3 294 944.89 2516 155 686.08 2989.7 228 832.1 2816 199 777.38 3126.9 253 876.53

5 3723.8 137 1013.6 1663.7 25.6 438.17 4364.9 195 1209.3 3306.2 106 891.62 3950.9 156 1081.7 3723.8 137 1013.6 4213.3 180 1161.9

Sensor 25 Sensor 26

DCR DFF DHF† DPF DMT†/DHT† DCR DFF

SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM

4 6263.45 1090 1819.4 2827.2 189 757.59 7347.5 1500 2134.3 5621.4 878 1632.9 6892.6 1320 2002.1 6263.45 1090 1819.4 7047.5 1380 2047.1

5 8148.5 747 2366.9 3798.1 138 1017.3 10066 1140 2924 7290.6 598 2117.8 8929.2 897 2593.7 8148.5 747 2366.9 9366.4 987 2720.7

6 10088 549 2930.2 4839.5 107 1293.6 12299 816 3572.4 9117 439 2620.3 11019 655 3200.7 10088 549 2930.2 11783 749 3422.6

8 14100 346 4028.2 6867.4 71.2 1827.3 16486 489 4788.8 12849 277 3604.2 15029 406 4363.5 14100 346 4029.2 16570 494 4813.2

10 18737 235 5232.7 9125.3 50.2 2418.5 21270 318 6087.1 17067 190 4750.1 19910 271 5619.2 18737 235 5232.7 22053 348 6367.7

12 23218 174 6391.4 11299 38 2986.8 26142 228 7316.3 21180 142 5773.9 24588 198 6815 23218 174 6391.4 27773 263 7857.8

14 25971 147 7099.9 12665 32.6 3343.5 29131 190 8071.7 23752 121 6441.4 27511 167 7567.4 25971 147 7099.9 31411 226 8803.3

16 30390 116 8238.9 14829 26.1 3908.1 33874 147 9274.7 27865 96.3 7506.8 32028 130 8721.9 30390 116 8238.9 37265 182 10320

18 34880 94.2 9397.7 17017 21.4 4479.2 38584 117 10473 32060 78.8 8595.3 36692 105 9921.8 34880 94.2 9397.7 43086 149 11819

20 39558 77.7 10608 19311 17.8 5077.3 43384 94.5 11699 36469 65.5 9139.6 41459 85.8 11147 39558 77.7 10608 49210 124 13401

24 48768 55.7 12990 23901 13 6275.5 52897 66 14140 45250 47.7 12021 50822 60.7 13560 48768 55.7 12990 61463 90.6 16567

30 65577 35.6 17355 32211 8.43 8445.5 70325 41.1 18648 61287 31 16195 67950 38.3 18002 65577 35.6 17355 83933 59.3 22399

36 80406 25.2 21207 39598 6.03 1037.4 85555 28.6 22592 75714 22.3 19949 83023 26.9 21911 80406 25.2 21207 103900 42.6 27573

42 95305 18.8 25083 47023 4.53 12313 100650 21 26510 90424 16.9 23782 98014 19.9 25807 95305 18.8 25083 123750 32 32725

Flow-391

Page 18: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diamond II+ Annubar®

Flow-3

Diamond

II+Annubar®

HW = hw = maximum differential pressure in inches of water column Structural limits apply to 200°F and below.

SCFM = maximum air flow in standard cubic feet per minute For applications requiring higher values, consult factory

GPM = maximum water flow in gallons per minute 1.2 in. to 24 in. Sch 40

At standard conditions: air: 60°F at 14.73 psia 30 in. to 42 in. Sch Std.

water: 60°F, specific gravity 1.0, viscosity 1.12 centipoise 48 in. to 72 in. Actual Id

† During insertion and retraction of Flo–Tap sensors, flow rate must be reduced to give lower DP values equal to the DP limits of DFF models of the same sensor size.

Nom.Pipe

Size (ininches)

Sensor 35 Sensor 36

DCR DFF DHF† DPF DMT†/DHT† DCR DFF

SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM

8 20661 768 6001.4 9950.2 153 2678.7 24501 1080 7116.8 18338 605 5326.6 22166 884 6438.7 20661 768 6001.4 24387 1070 7083.8

10 26823 521 7791.3 13239 108 3547.4 31224 706 9069.8 24088 414 6945.3 28592 592 8305.3 26823 521 7791.3 32204 751 9351.3

12 32883 385 9507.2 16469 82.3 4395.6 37485 505 10088 30074 309 8519.3 34710 433 10082 32833 385 9507.2 39824 570 11568

14 37058 327 10589 18488 70.7 4923.8 41364 421 12015 33895 264 9514.6 38729 365 11188 37058 327 10589 44625 490 12962

16 43668 258 12287 21690 56.7 5760.1 48040 325 13791 39957 210 11085 45595 286 12937 43668 258 12287 52273 394 15184

18 50338 209 13998 24947 46.6 6609.8 55095 258 15553 46180 172 12699 52469 230 14685 50338 209 13998 60481 324 17429

20 57299 172 15783 28344 38.8 7496.1 62559 210 17439 52719 143 14391 59608 188 16501 57299 172 15783 69596 270 19774

24 71017 123 19303 36548 28.3 9259.1 76801 146 21031 65702 104 17750 73609 133 20072 71017 123 19303 87930 198 24491

30 96282 78.9 25837 47441 18.4 12477 103040 91.1 27763 89649 67.9 23969 999349 84.3 26707 96282 78.9 25837 121480 130 33165

36 118650 56 31613 58452 13.2 15348 125830 63.3 33611 11250 49 29572 121960 59.3 32531 118650 56 31613 151120 93.2 40783

42 1411020 41.8 37402 69564 9.95 18248 148640 46.6 39491 133070 37.1 35237 144570 44 35374 141020 41.8 37402 181070 70.3 48505

48 163400 32.4 43205 80662 7.76 21144 171330 35.7 45353 155040 29.1 40946 167050 33.9 44194 163400 32.4 43205 211020 54.9 56240

60 208140 21.1 54825 102920 5.1 26954 216230 22.8 56991 199180 19.3 52434 211980 21.9 55855 208140 21.1 54825 270800 36.1 71712

72 253470 14.9 66623 125280 3.61 32793 261750 15.9 68822 243170 13.7 63883 256820 15.3 67511 253470 14.9 66623 330970 25.6 87327

Sensor 45 Sensor 46

DCR DFF DHF† DPF DMT†/DHT† DCR DFF

SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM

10 41878 1270 12165 20133 256 5461.5 45513 1500 13220 37086 996 10713 N/A N/A N/A 41878 1270 12165 45513 1500 13220

12 51142 940 14855 24994 195 6766.1 59210 1260 17199 45499 744 13216 N/A N/A N/A 51142 940 14855 61288 1350 17803

14 56913 797 16532 28092 168 7590.1 65325 1050 18975 50681 635 14756 N/A N/A N/A 56913 797 16532 68661 1160 19944

16 66100 630 19200 33012 135 8888.1 74858 808 21744 59297 507 17224 N/A N/A N/A 66100 630 19200 80698 939 23441

18 75353 511 21888 38019 111 10201 84461 642 24534 68260 416 19749 N/A N/A N/A 75353 511 21888 92738 774 26938

20 85108 422 24722 43418 93.2 11618 94565 521 27469 78331 346 22385 N/A N/A N/A 85108 422 24722 105460 648 30634

24 106480 303 30297 53975 68.2 14374 114620 364 33207 98553 252 27630 N/A N/A N/A 106480 303 30291 130590 475 37933

30 146170 194 40515 73415 44.7 19448 156190 226 43729 136026 165 37364 N/A N/A N/A 146170 194 40515 178800 313 51462

36 181760 138 49627 90648 32.1 23938 192700 157 52933 169830 119 46084 N/A N/A N/A 181760 138 49627 226020 226 63508

42 217210 103 58712 108240 24.3 28517 229510 116 62307 204130 90.2 54943 N/A N/A N/A 217210 103 58712 273660 171 75649

48 251110 78.8 67379 125770 19 33086 265390 88.6 71446 238660 70.8 63867 N/A N/A N/A 251110 78.8 67379 321370 134 87865

60 321930 51.5 85653 160730 12.5 42190 337470 56.8 89952 308340 4701 81912 N/A N/A N/A 321930 51.5 85653 416410 88.4 112220

72 392880 36.3 103990 195900 8.86 51374 408770 39.4 108340 378250 33.6 100050 N/A N/A N/A 392880 36.3 103990 511830 62.8 136780

92

Page 19: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

4. CHOOSE THE MODEL OPTIONS

Model Numbers Description Page Numbers

Standard Models Line Sizes 2 Inches and Larger

DCR+15/16S Diamond II+ Annubar Primary Flow Element—Regular (Pak-Lok, Threaded), SST page 395

DCR+25/26S Diamond II+ Annubar Primary Flow Element—Regular (Pak-Lok, Threaded), SST page 397

DCR+35/36S Diamond II+ Annubar Primary Flow Element—Regular (Pak-Lok, Threaded), SST page 400

DCR+45/46S Diamond II+ Annubar Primary Flow Element—Regular (Pak-Lok, Threaded), SST page 403

DFF+15/16S Diamond II+ Annubar Primary Flow Element—Flanged, SST page 409

DFF+25/26S Diamond II+ Annubar Primary Flow Element—Flanged, SST page 411

DFF+25/26H Diamond II+ Annubar Primary Flow Element—Flanged, Hastelloy–C page 414

DFF+25/26M Diamond II+ Annubar Primary Flow Element—Flanged, Monel page 417

DFF+35/36S Diamond II+ Annubar Primary Flow Element—Flanged, SST page 420

DFF+45/46S Diamond II+ Annubar Primary Flow Element—Flanged, SST page 423

DFF+45/46H Diamond II+ Annubar Primary Flow Element—Flanged, Hastelloy–C page 426

DFF+45/46M Diamond II+ Annubar Primary Flow Element—Flanged, Monel page 428

DPF+15/16S Diamond II+ Annubar Primary Flow Element—Pak-Lok Flanged, SST page 434

DPF+25/26S Diamond II+ Annubar Primary Flow Element—Pak-Lok Flanged, SST page 436

DPF+35/36S Diamond II+ Annubar Primary Flow Element—Pak-Lok Flanged, SST page 438

DPF+45/46S Diamond II+ Annubar Primary Flow Element—Pak-Lok Flanged, SST page 440

In–line sizes: ½ in. to 2 in.

DNT+10S Diamond II+ Annubar Primary Flow Element—In-Line Threaded, SST page 446

DNF+10S Diamond II+ Annubar Primary Flow Element—In-Line Flanged, SST page 447

DNF+10H Diamond II+ Annubar Primary Flow Element—n-Line Flanged, Hastelloy–C page 449

DNF+10M Diamond II+ Annubar Primary Flow Element—In-Line Flanged, Monel page 450

DNW+10S Diamond II+ Annubar Primary Flow Element—In-Line Butt Weld, SST page451

Flo–Tap Models

DMT+15S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 456

DMT+25S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 458

DMT+35S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 461

DHT+15S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 469

DHT+25S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 471

DHT+35S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 474

DHF+15S Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, SST page 482

DHF+25S Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, SST page 485

DHF+25H Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, Hastelloy–C page 488

DHF+25M Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, Monel page 491

DHF+35S Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, SST page 494

DHF+45S Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, SST page 497

DHF+45H Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, Hastelloy–C page 500

DHF+45M Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, Monel page 503

Flow-393

Page 20: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-3

Diamond II+ Annubar®

Diamond

II+Annubar®

5. VERIFY PROCESS AND PIPE INFORMATION

Configuration Information

When ordering an Annubar primary flow element, it is important to include all of the flowing conditions and pipe information for your application. This will ensure that you receive the correct product for your application. Please see the Annubar primary flow element Configuration Data Sheet 00806–0100–4760.

Dimension CodesCertain dimensions are critical to fabrication of the primary flow element assembly. The following codes can be specified in the model callout “string” and Dieterich Standard, Inc. will build the primary flow element assembly to suit. If no dimension is specified, cataloged components will default to standard dimensions.

ODH

ODH is the outside diameter of the pipe to the top of the Annubar primary flow element head (Figure 41). If this dimension is specified for a flanged, Flo–Tap, or Regular model, the neck of the primary flow element just below standard dimension can be considered a minimum. This dimension does not apply to in–line sensors or to model 45s.

FIGURE 41. ODH.

ODF

ODF is the outside diameter of the pipe to the face of the mounting flange (Figure 42). This dimension applies only to DFF, DHF, DSF, NFF, SPF, SFF, and SSF models. If Dieterich Standard, Inc. is not supplying the mounting hardware, this dimension must be specified. If Dieterich Standard, Inc. is providing the mounting flange assembly, note the following:

• The standard ODF is a minimum.

• The extensions must be at least 2 inches longer than the minimum ODF.

FIGURE 42. ODF.

ODV

ODV is the outside diameter of the pipe to the top of the isolation valve (Figure 43). ODV applies to Flo–Tap models only, and only when the customer supplies some or all of the mounting hardware.

FIGURE 43. ODV.

NL

NL is the nipple length for DNW, DNF, and DNT-10 in-line models (Figure 44). Additional length can be specified to fit specific piping configurations. The extra length will be applied upstream of the sensor unless otherwise specified.

FIGURE 44. NL.

CMH

CMH is the customer mount height distance from the outside of the pipe to the top of the appropriately sized NPT threaded female mounting coupling (Figure 45). Supply these values for Regular and Flo–Tap models that are being installed in a customer’s mounting or saddle.

FIGURE 45. CMH.

ODH

ODF

ODV

CMH

94

Page 21: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Ordering Information—Model DCRMODEL DCR+15S/16S

Model Product Description

DCR+15SDCR+16S

Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok)Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok) with Opposite Side Support, SST

Code Line Size

020025030035040050

2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)

Code Head Style

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0SA2C0CP2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Steam, 1/2—14 NPT, CS

CP2S0SA2S0CP2SSSP2S0SP2SSCA2S0CA2SS

Needle Valves - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SST

CB2C0SB2C0CC2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST

SV2S0SV2SS

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2 in. Socket Weld Ports, SST

Code Mounting Hardware

MP2C0MP2S0MR2C0MR2S0

Pak-Lok, with Contoured Weld Fitting, 1/2—14 NPT, CSPak-Lok, with Contoured Weld Fitting, 1/2—14 NPT, SSTPak-Lok, No Contoured Weld Fitting, 1/2—14 NPT, CSPak-Lok, No Contoured Weld Fitting, 1/2—14 NPT, SST

Flow-395

Page 22: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-3

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Opposite Side Support (Required for Model 16S only)

MS2C0MS2CWMS2S0MS2SW

Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST

Code Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)

MT2CMT2SME2CME2AME2KME2PME2SNB20NC20ND20NE20NF20

Contoured Weld Fitting, 1/2—14 NPT, CSContoured Weld Fitting, 1/2—14 NPT, SSTWeld Coupling, 1/2—14 NPT, CSWeld Coupling, 1/2—14 NPT, AluminumWeld Coupling, 1/2—14 NPT, CopperWeld Coupling, 1/2—14 NPT, PVCWeld Coupling, 1/2—14 NPT, SSTSaddle, Double Strap, 2.35 to 2.56 O.D., 1/2—14 NPT, IronSaddle, Double Strap, 2.41 to 2.91 O.D., 1/2—14 NPT, IronSaddle, Double Strap, 2.97 to 3.54 O.D., 1/2—14 NPT, IronSaddle, Double Strap, 4.14 to 4.80 O.D., 1/2—14 NPT, IronSaddle, Double Strap, 5.94 to 6.70 O.D., 1/2—14 NPT, Iron

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXR

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

Code Optional Calibration

MZ

Lab Flow Calibration (Average K) (<10 in.)Special Calibration

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DCR+15S 020 HA2S0 CA2C0 MP2C0

MODEL DCR+15S/16S

96

Page 23: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

MODEL DCR+25S/26SModel Product Description

DCR+25SDCR+26S

Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok)Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok) with Opposite Side Support, SST

Code Line Size

040050060080100120140160180200240300360420

4 in. (100 mm)5 in. (125 mm)6 in. (150mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)

Code Head Style

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST

HATSNHATSBHATSDHATS0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HVTSBHVTSDHVTSNHVTS0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0SA2C0CP2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

Flow-397

Page 24: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-3

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Instrument Connections (Continued)

CP2S0SA2S0CP2SSSP2S0SP2SSCA2S0CA2SS

Needle Valves - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SST

CB2C0SB2C0CC2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Mounting Hardware

MR4C0MR4S0MP4C0MP4S0

Pak-Lok, No Contoured Weld Fitting, 1—11.5 NPT, CSPak-Lok, No Contoured Weld Fitting, 1—11.5 NPT, SSTPak-Lok, with Contoured Weld Fitting, 1—11.5 NPT, CSPak-Lok, with Contoured Weld Fitting, 1—11.5 NPT, SST

Code Opposite Side Support (Required for Model 26S only)

MS4C0MS4CWMS4S0MS4SW

Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST

Code Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)

MT4CMT4SME4CME4AME4KME4PME4SNE40NF40NG40NH40NJ40

Contoured Weld Fitting, 1—11.5 NPT, CSContoured Weld Fitting, 1—11.5 NPT, SSTWeld Coupling, 1—11.5 NPT, CSWeld Coupling, 1—11.5 NPT, AluminumWeld Coupling, 1—11.5 NPT, CopperWeld Coupling, 1—11.5 NPT, PVCWeld Coupling, 1—11.5 NPT, SSTSaddle, Double Strap, 3.74 to 4.55 O.D., 1—11.5 NPT, IronSaddle, Double Strap, 5.94 to 6.7 O.D., 1—11.5 NPT, IronSaddle, Double Strap, 8.54 to 10.1 O.D., 1—11.5 NPT, IronSaddle, Double Strap,10.64 to 12.12 O.D., 1—11.5 NPT, IronSaddle, Double Strap, 12.6 to 14.3 O.D., 1—11.5 NPT, Iron

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

MODEL DCR+25S/26S

98

Page 25: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DCR+25S 040 HAMS0 C0000 MP4C0

MODEL DCR+25S/26S

Flow-399

Page 26: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODEL DCR+35S/36SModel Product Description

DCR+35SDCR+36S

Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok)Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok) with Opposite Side Support, SST

Code Line Size

080100120140160180200240300360420480600720

8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST

HATSNHATSBHATSDHATS0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HVTSBHVTSDHVTSNHVTS0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0SA2C0CP2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

00

Page 27: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CP2S0SA2S0CP2SSSP2S0SP2SSCA2S0CA2SS

Needle Valves - SSTNeedle Valve, Nipple, 1/2—14 NPT,Needle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SST

CB2C0SB2C0CC2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Mounting Hardware

MP6C0MP6S0MR6C0MR6S0

Pak-Lok, with Contoured Weld Fitting, 11/2—11.5 NPT, CSPak-Lok, with Contoured Weld Fitting, 11/2—11.5 NPT, SSTPak-Lok, No Contoured Weld Fitting, 11/2—11.5 NPT, CSPak-Lok, No Contoured Weld Fitting, 11/2—11.5 NPT, SST

Code Opposite Side Support (Required for Model 36S only)

MS6C0MS6CWMS6S0MS6SW

Contoured Weld Fitting and Plug, 11/2—11.5 NPT, CSContoured Weld Fitting and Plug, 11/2 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 11/2—11.5 NPT, SSTContoured Weld Fitting and Plug, 11/2 in. Socket Weld Ports, SST

Code Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)

MT6CMT6S

Contoured Weld Fitting, 11/2—11.5 NPT, CSContoured Weld Fitting, 11/2—11.5 NPT, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

MODEL DCR+35S/36S

Flow-401

Page 28: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Optional Quality Assurance

QA1QA2Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramCertified ProgramANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DCR+35S 120 HAMS0 C0000 MP6C0

MODEL DCR+35S/36S

02

Page 29: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

MODEL DCR+45S/46SModel Product Description

DCR+45SDCR+46S

Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok)Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok) with Opposite Side Support, SST

Code Line Size

100120140160180200240300360420480600720

10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST

HATSNHATSBHATSDHATS0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HVTSBHVTSDHVTSNHVTS0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP2C0SP2C0

Needle Valves - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

CP2S0CP2SSSP2S0SP2SS

Needle Valves - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple,1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Flow-403

Page 30: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Instrument Connections (Continued)

CC2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2SSCC2S0CC2SSSC2S0SV2S0SV2SS

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow,1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2 in. Socket Weld Ports, SST

Code Mounting Hardware

MPDC0MPDS0

Pak-Lok, with Contoured Weld Fitting, 3—8 NPT, CSPak-Lok, with Contoured Weld Fitting, 3—8 NPT, SST

Code Opposite Side Support (Required for Model 46S only)

MSDCWMSDSW

Contoured Weld Fitting and Cap, 3 in., Butt Weld, CSContoured Weld Fitting and Cap, 3 in., Butt Weld, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DCR+45S 200 HAMS0 C0000 MPDC0

MODEL DCR+45S/46S

04

Page 31: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-405

Page 32: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

06

Page 33: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-407

Page 34: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

08

Page 35: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Ordering Information—Model DFFMODEL DFF+15S/16S

Model Product Description

DFF+15SDFF+16S

Diamond II+ Annubar® Primary Flow Element - Flanged, SSTDiamond II+ Annubar® Primary Flow Element - Flanged with Opposite Side Support, SST

Code Line Size

020025030035040050

2 in. (50 mm)2½ in. (63.5 mm)3 in. (80 mm)3½ in. (89 mm)4 in. (100 mm)5 in. (125 mm)

Code Head Style

HAMS0HADS0HADSBHADSNHAPS0

Direct Mount - HorizontalIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST

HVPS0HVMS0HVDS0HVDSBHVDSN

Direct Mount - VerticalDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SSHAHS0HAHSS

Remote Mount - HorizontalAxial, Horizontal Line, ½—14 NPT, SSTAxial, Horizontal Line, ½ in. Socket Weld Ports, SSTParallel, Horizontal Line, ½—14 NPT, SSTParallel, Horizontal Line, ½ in. Socket Weld Ports, SSTAxial, HP, Horizontal Line, ½—14 NPT, SSTAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SSHVHS0HVHSS

Remote Mount - VerticalParallel, Vertical Line, ½ in. Socket Weld Ports, SSTParallel, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½ in. Socket Weld Ports, SSTAxial, HP, Vertical Line, ½—14 NPT, SSTAxial, HP, Vertical Line, ½ in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, ½—14 NPT, CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Elbow and Tee, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valves - SSTNeedle Valve, Elbow, ½—14 NPT, SSTNeedle Valve, Elbow, ½ in. Socket Weld Ports, SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple, ½ in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½ in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS

Flow-409

Page 36: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

10

Code Instrument Connections (Continued)

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in. Socket Weld Ports, SST

Code Sensor Flange

FNMS0FLMS0FJMS0FF4S0FE4S0FC4S0FB4S0FA4S0

DIN 25 PN 100, 316 SSTDIN 25 PN 40, 316 SSTDIN 25 PN 16, 316 SST1 in. ANSI Class 2500, RF, SST1 in. ANSI Class 900/1500, RF, SST1 in. ANSI Class 600, RF, SST1 in. ANSI Class 300, RF, SST1 in. ANSI Class 150, RF, SST

Code Flanged Mount

FA4CFA4SFB4CFB4SFC4CFC4SFE4CFE4SFF4CFF4SFJMCFJMSFLMCFLMSFNMCFNMS

1 in. ANSI Class 150, Weld-Neck RF, CS1 in. ANSI Class 150, Weld-Neck RF, SST1 in. ANSI Class 300, Weld-Neck RF, CS1 in. ANSI Class 300, Weld-Neck RF, SST1 in. ANSI Class 600, Weld-Neck RF, CS1 in. ANSI Class 600, Weld-Neck RF, SST1 in. ANSI Class 900/1500, Weld-Neck RF, CS1 in. ANSI Class 900/1500, Weld-Neck RF, SST1 in. ANSI Class 2500, Weld-Neck RF, CS1 in. ANSI Class 2500, Weld-Neck RF, SSTDIN 25 PN 16, CSDIN 25 PN 16, 316 SSTDIN 25 PN 40, CSDIN 25 PN 40, 316 SSTDIN 25 PN 100, CSDIN 25 PN 100, 316 SST

Code Opposite Side Support (Required for Model 16S only)

MS2C0MS2CWMS2S0MS2SW

Contoured Weld Fitting and Plug, ½—14 NPT, CSContoured Weld Fitting and Plug, ½ in. Socket Weld Ports, CSContoured Weld Fitting and Plug, ½—14 NPT, SSTContoured Weld Fitting and Plug, ½ in. Socket Weld Ports, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXR

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

Code Optional Calibration

MZ

Lab Flow Calibration (Average K) (<10 in.)Special Calibration

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DFF+15S 020 HAMS0 C0000 FA4S0 FA4C

MODEL DFF+15S/16S

Page 37: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

MODEL DFF+25S/26SModel Product Description

DFF+25SDFF+26S

Diamond II + Annubar® Primary Flow Element - Flanged, SSTDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, SST

Code Line Size

040050060080100120140160180200240300360420

4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)

Code Head Style

HAMS0HADS0HADSBHADSNHAPS0HAXS0

Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTDirect Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST

HATSNHATS0HATSBHATSD

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST

HVPS0HVMS0HVDS0HVDSBHVDSN

Direct and Integral Mount Heads - Vertical LineDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SST

HVTS0HVTSBHVTSDHVTSN

Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SSHAHS0HAHSS

Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, SSTAxial, Horizontal Line, ½ in. Socket Weld Ports, SSTParallel, Horizontal Line, ½—14 NPT, SSTParallel, Horizontal Line, ½ in. Socket Weld Ports, SSTAxial, HP, Horizontal Line, ½—14 NPT, SSTAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SSHVHS0HVHSS

Remote Mount - Vertical LineParallel, Vertical Line, ½ in. Socket Weld Ports, SSTParallel, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½ in. Socket Weld Ports, SSTAxial, HP, Vertical Line, ½—14 NPT, SSTAxial, HP, Vertical Line, ½ in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, ½—14 NPT, CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Elbow and Tee, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS

Flow-411

Page 38: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Instrument Connections (Continued)

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valves - SSTNeedle Valve, Elbow, ½—14 NPT, SSTNeedle Valve, Elbow, ½ in. Socket Weld Ports, SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple, ½ in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½ in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in. Socket Weld Ports, SST

Code Sensor Flange

FNPS0FLPS0FJPS0FF8S0FE8S0FC6S0FB6S0FA6S0

DIN 40 PN 100, 316 SSTDIN 40 PN 40, 316 SSTDIN 40 PN 16, 316 SST2 in. ANSI Class 2500, RF, SST2 in. ANSI Class 900/1500, RF, SST1½ in. ANSI Class 600, RF, SST1½ in. ANSI Class 300, RF, SST1½ in. ANSI Class 150, RF, SST

Code Flanged Mount

FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8SFJPCFJPSFLPCFLPSFNPCFNPS

1½ in. ANSI Class 150, Weld-Neck RF, CS1½ in. ANSI Class 150, Weld-Neck RF, SST1½ in. ANSI Class 300, Weld-Neck RF, CS1½ in. ANSI Class 300, Weld-Neck RF, SST1½ in. ANSI Class 600, Weld-Neck RF, CS1½ in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500,Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SSTDIN 40 PN 16, CSDIN 40 PN 16, 316 SSTDIN 40 PN 40, CSDIN 40 PN 40, 316 SSTDIN 40 PN 100, CSDIN 40 PN 100, 316 SST

Code Opposite Side Support (Required for Model 26S only)

MS4C0MS4CWMS4S0MS4SW

Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

MODEL DFF+25S/26S

12

Page 39: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DFF+25S 040 HAMS0 C0000 FA6S0 FA6C

MODEL DFF+25S/26S

Flow-413

Page 40: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODEL DFF+25H/26HModel Product Description

DFF+25HDFF+26H

Diamond II + Annubar® Primary Flow Element - Flanged, Hastelloy-CDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, Hastelloy-C

Code Line Size

040050060080100120140160180200240300360420

4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)

Code Head Style

HADH0HADHBHADHNHAMH0HAPH0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CIntegral, 3-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-C

HATH0HATHDHATHNHATHB

Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Hastelloy-C

HVMH0HVDH0HVDHBHVDHNHVPH0

Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-C

HVTH0HVTHBHVTHDHVTHN

Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C

HA2H0HA2HSHP2H0HAHH0HAHHS

Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, Horizontal Line, ½ in. Socket Weld Ports, Hastelloy-CParallel, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, HP, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, Hastelloy-C

HPVH0HV2H0HVHH0HVHHS

Remote Mount - Vertical LineParallel, Vertical Line, ½—14 NPT, Hastelloy-CAxial, Vertical Line, ½—14 NPT, Hastelloy-CAxial, HP, Vertical Line, ½—14 NPT, Hastelloy-CAxial, HP, Vertical Line, ½ in. Socket Weld Ports, Hastelloy-C

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, ½—14 NPT, CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Elbow and Tee, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS

14

Page 41: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CA2S0CP2S0SA2S0SP2S0

Needle Valves - SSTNeedle Valve, Elbow, ½—14 NPT, SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Elbow and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST

CA2H0CP2H0

Needle Valves - Hastelloy-CNeedle Valve, Elbow, ½—14 NPT, Hastelloy-CNeedle Valve, Nipple, ½—14 NPT, Hastelloy-C

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS

CB2S0CC2S0SB2S0SC2S0SV2S0

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST

Code Sensor Flange

FF8H0FE8H0FC6H0FB6H0FA6H0

2 in. ANSI Class 2500, RF, Hastelloy-C2 in. ANSI Class 900/1500, RF, Hastelloy-C1½ in. ANSI Class 600, RF, Hastelloy-C1½ in. ANSI Class 300, RF, Hastelloy-C1½ in. ANSI Class 150, RF, Hastelloy-C

Code Flanged Mount

FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8S

1½ in. ANSI Class 150, Weld-Neck RF, CS1½ in. ANSI Class 150, Weld-Neck RF, SST1½ in. ANSI Class 300, Weld-Neck RF, CS1½ in. ANSI Class 300, Weld-Neck RF, SST1½ in. ANSI Class 600, Weld-Neck RF, CS1½ in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500, Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SST

Code Opposite Side Support (Required for Model 26H only)

MS4C0MS4CWMS4S0MS4SW

Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

MODEL DFF+25H/26H

Flow-415

Page 42: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DFF+25H 040 HAMH0 C0000 FA6H0 FA6C

MODEL DFF+25H/26H

16

Page 43: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

MODEL DFF+25M/26MModel Product Description

DFF+25MDFF+26M

Diamond II + Annubar® Primary Flow Element - Flanged, MonelDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, Monel

Code Line Size

040050060080100120140160180200240300360420

4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)

Code Head Style

HADM0HADMBHADMNHAMM0HAPM0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelIntegral, 3-Valve Manifold, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, Monel

HATM0HATMDHATMNHATMB

Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Monel

HVMM0HVDM0HVDMBHVDMNHVPM0

Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, MonelDirect Mount, 5-Valve Manifold, NACE, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, Monel

HVTM0HVTMBHVTMDHVTMN

Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel

HA2M0HA2MSHP2M0HAHM0HAHMS

Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, MonelAxial, Horizontal Line, ½ in. Socket Weld Ports, MonelParallel, Horizontal Line, ½—14 NPT, MonelAxial, HP, Horizontal Line, ½—14 NPT, MonelAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, Monel

HPVM0HVHM0HVHMSHV2MOHV2MS

Remote Mount - Vertical LineParallel, Vertical Line, ½—14 NPT, MonelAxial, HP, Vertical Line, ½—14 NPT, MonelAxial, HP, Vertical Line, ½ in. Socket Weld Ports, MonelAxial, Vertical Line, ½—14 NPT, MonelAxial, Vertical Line, ½ in. Socket Weld Ports, Monel

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, ½—14 NPT, CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Elbow and Tee, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS

Flow-417

Page 44: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Instrument Connections (Continued)

CA2S0CP2S0SA2S0SP2S0

Needle Valves - SSTNeedle Valve, Elbow, ½—14 NPT, SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Elbow and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST

CA2M0CP2M0

Needle Valves - MonelNeedle Valve, Elbow, ½—14 NPT, MonelNeedle Valve, Nipple, ½—14 NPT, Monel

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS

CB2S0CC2S0SB2S0SC2S0SV2S0

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST

Code Sensor Flange

FE8M0FF8M0FC6M0FB6M0FA6M0

2 in. ANSI Class 900/1500, RF, Monel2 in. ANSI Class 2500, RF, Monel1½ in. ANSI Class 600, RF, Monel1½ in. ANSI Class 300, RF, Monel1½ in. ANSI Class 150, RF, Monel

Code Flanged Mount

FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8S

1½ in. ANSI Class 150, Weld-Neck RF, CS1½ in. ANSI Class 150, Weld-Neck RF, SST1½ in. ANSI Class 300, Weld-Neck RF, CS1½ in. ANSI Class 300, Weld-Neck RF, SST1½ in. ANSI Class 600, Weld-Neck RF, CS1½ in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500, Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SST

Code Opposite Side Support (Required for Model 26M only)

MS4C0MS4CWMS4S0MS4SW

Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

MODEL DFF+25M/26M

18

Page 45: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DFF+25M 040 HAMM0 C0000 FA6M0 FA6C

MODEL DFF+25M/26M

Flow-419

Page 46: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODEL DFF+35S/36SModel Product Description

DFF+35SDFF+36S

Diamond II + Annubar® Primary Flow Element - Flanged, SSTDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, SST

Code Line Size

080100120140160180200240300360420480600720

8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HAMS0HADS0HADSBHADSNHAPS0HAXS0

Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTDirect Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST

HATSNHATS0HATSBHATSD

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST

HVPS0HVMS0HVDS0HVDSBHVDSN

Direct and Integral Mount Heads - Vertical LineDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SST

HVTS0HVTSBHVTSDHVTSN

Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SSHAHS0HAHSS

Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, SSTAxial, Horizontal Line, ½ in. Socket Weld Ports, SSTParallel, Horizontal Line, ½—14 NPT, SSTParallel, Horizontal Line, ½ in. Socket Weld Ports, SSTAxial, HP, Horizontal Line, ½—14 NPT, SSTAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SSHVHS0HVHSS

Remote Mount - Vertical LineParallel, Vertical Line, ½ in. Socket Weld Ports, SSTParallel, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½ in. Socket Weld Ports, SSTAxial, HP, Vertical Line, ½—14 NPT, SSTAxial, HP, Vertical Line, ½ in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, ½—14 NPT, CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Elbow and Tee, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS

20

Page 47: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valves - SSTNeedle Valve, Elbow, ½—14 NPT, SSTNeedle Valve, Elbow, ½ in. Socket Weld Ports, SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple, ½ in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½ in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in. Socket Weld Ports, SST

Code Sensor Flange

FNRS0FLRS0FJRS0FFDS0FEDS0FDDS0FC8S0FBDS0FA8S0

DIN 50 PN 100, 316 SSTDIN 50 PN 40, 316 SSTDIN 50 PN 16, 316 SST3 in. ANSI Class 2500, RF, SST3 in. ANSI Class 1500, RF, SST3 in. ANSI 900, RF, SST2 in. ANSI Class 600, RF, SST3 in. ANSI Class 300, RF, SST2 in. ANSI Class 150, RF, SST

Code Flanged Mount

FA8CFA8SFB8CFB8SFC8CFC8SFDDCFDDSFEDCFEDSFFDCFFDSFJRCFJRSFLRCFLRSFNRCFNRS

2 in. ANSI Class 150, Weld-Neck RF,CS2 in. ANSI Class 150, Weld-Neck RF, SST2 in. ANSI Class 300, Weld-Neck RF, CS2 in. ANSI Class 300, Weld-Neck RF, SST2 in. ANSI Class 600, Weld-Neck RF, CS2 in. ANSI Class 600, Weld-Neck RF, SST3 in. ANSI Class 900, Weld-Neck RF, CS3 in. ANSI Class 900, Weld-Neck RF, SST3 in. ANSI Class 1500, Weld-Neck RF, CS3 in. ANSI Class 1500, Weld-Neck RF, SST3 in. ANSI Class 2500, Weld-Neck RF, CS3 in. ANSI Class 2500, Weld-Neck RF, SSTDIN 50 PN 16, CSDIN 50 PN 16, 316 SSTDIN 50 PN 40, CSDIN 50 PN 40, 316 SSTDIN 50 PN 100, CSDIN 50 PN 100, 316 SST

Code Opposite Side Support (Required for Model 36S only)

MS6C0MS6CWMS6S0MS6SW

Contoured Weld Fitting and Plug, 1½—11.5 NPT, CSContoured Weld Fitting and Plug, 1½ in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1½—11.5 NPT, SSTContoured Weld Fitting and Plug, 1½ in. Socket Weld Ports, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

MODEL DFF+35S/36S

Flow-421

Page 48: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DFF+35S 080 HAMS0 C0000 FA8S0 FA8C

MODEL DFF+35S/36S

22

Page 49: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

MODEL DFF+45S/46SModel Product Description

DFF+45SDFF+46S

Diamond II + Annubar® Primary Flow Element - Flanged, SSTDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, SST

Code Line Size

100120140160180200240300360420480600720

10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HAMS0HADS0HADSBHADSNHAPS0HAXS0

Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTDirect Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST

HATSNHATS0HATSBHATSD

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST

HVPS0HVMS0HVDS0HVDSBHVDSN

Direct and Integral Mount Heads - Vertical LineDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SST

HVTS0HVTSBHVTSDHVTSN

Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SSHAHS0HAHSSHSHS0

Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, SSTAxial, Horizontal Line, ½ in. Socket Weld Ports, SSTParallel, Horizontal Line, ½—14 NPT, SSTParallel, Horizontal Line, ½ in. Socket Weld Ports, SSTAxial, HP, Horizontal Line, ½—14 NPT, SSTAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, SSTStack Head with Purge, Horizontal Line, ½—14 NPT, SST

HPVS0HPVSSHV2S0HV2SSHVHS0HVHSSHSVS0

Remote Mount - Vertical LineParallel, Vertical Line, ½ in. Socket Weld Ports, SSTParallel, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½ in. Socket Weld Ports, SSTAxial, HP, Vertical Line, ½—14 NPT, SSTAxial, HP, Vertical Line, ½ in. Socket Weld Ports, SSTStack Head with Purge, Vertical Line, ½—14 NPT, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP2C0SP2C0

Needle Valves - CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS

Flow-423

Page 50: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Instrument Connections (Continued)

CP2S0SP2S0CP2SSSP2SS

Needle Valves - SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SSTNeedle Valve, Nipple, ½ in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, ½ in. Socket Weld Ports, SST

CC2S0SC2S0SV2S0CB2SSCC2SSSV2SS

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in. Socket Weld Ports, SST

Code Sensor Flange

FNTS0FLTS0FJTS0FFDS0FEDS0FDDS0FCDS0FBDS0FADS0

DIN 80 PN 100, 316 SSTDIN 80 PN 40, 316 SSTDIN 80 PN 16, 316 SST3 in. ANSI Class 2500, RF, SST3 in. ANSI Class 1500, RF, SST3 in. ANSI Class 900, RF, SST3 in. ANSI Class 600, RF, SST3 in. ANSI Class 300, RF, SST3 in. ANSI Class 150, RF, SST

Code Flanged Mount

FDDCFDDSFFDCFFDSFADCFADSFBDCFBDSFCDCFCDSFJTCFJTSFLTCFLTSFNTCFNTS

3 in. ANSI Class 900, Weld-Neck RF, CS3 in. ANSI Class 900, Weld-Neck RF, SST3 in. ANSI Class 2500, Weld-Neck RF, CS3 in. ANSI Class 2500, Weld-Neck RF, SST3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SSTDIN 80 PN 16, CSDIN 80 PN 16, 316 SSTDIN 80 PN 40, CSDIN 80 PN 40, 316 SSTDIN 80 PN 100, CSDIN 80 PN 100, 316 SST

Code Opposite Side Support (Required for Model 46S only)

MSDCWMSDSW

Contoured Weld Fitting and Cap, 3 in., BW, CSContoured Weld Fitting and Cap, 3 in., BW, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

MODEL DFF+45S/46S

24

Page 51: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DFF+45S 240 HAMS0 C0000 FADS0 FADC

MODEL DFF+45S/46S

Flow-425

Page 52: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODEL DFF+45H/46HModel Product Description

DFF+45HDFF+46H

Diamond II + Annubar® Primary Flow Element - Flanged, Hastelloy-CDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, Hastelloy-C

Code Line Size

100120140160180200240300360420480600720

10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HADH0HADHBHADHNHAMH0HAPH0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CIntegral, 3-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-C

HATH0HATHDHATHNHATHB

Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Hastelloy-C

HVMH0HVDH0HVDHBHVDHNHVPH0

Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-C

HVTH0HVTHBHVTHDHVTHN

Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C

HA2H0HA2HSHP2H0HAHH0HAHHS

Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, Horizontal Line, ½ in. Socket Weld Ports, Hastelloy-CParallel, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, HP, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, Hastelloy-C

HPVH0HV2H0HVHH0HVHHSHSVH0

Remote Mount - Vertical LineParallel, Vertical Line, ½—14 NPT, Hastelloy-CAxial, Vertical Line, ½—14 NPT, Hastelloy-CAxial, HP, Vertical Line, ½—14 NPT, Hastelloy-CAxial, HP, Vertical Line, ½ in. Socket Weld Ports, Hastelloy-CStack Head with Purge, Vertical Line, ½—14 NPT, Hastelloy-C

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP2C0SP2C0

Needle Valves - CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS

CP2S0SP2S0

Needle Valves - SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST

CP2H0Needle Valves - Hastelloy-CNeedle Valve, Nipple, ½—14 NPT, Hastelloy-C

26

Page 53: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CC2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS

CC2S0SC2S0SV2S0

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST

Code Sensor Flange

FDDH0FFDH0FEDH0FCDH0FBDH0FADH0

3 in. ANSI Class 900, RF, Hastelloy-C3 in. ANSI Class 2500, RF, Hastelloy-C3 in. ANSI Class 1500, RF, Hastelloy-C3 in. ANSI Class 600, RF, Hastelloy-C3 in. ANSI Class 300, RF, Hastelloy-C3 in. ANSI Class 150, RF, Hastelloy-C

Code Flanged Mount

FDDCFDDSFFDCFFDSFADCFADSFBDCFBDSFCDCFCDS

3 in. ANSI Class 900, Weld-Neck RF, CS3 in. ANSI Class 900, Weld-Neck RF, SST3 in. ANSI Class 2500, Weld-Neck RF, CS3 in. ANSI Class 2500, Weld-Neck RF, SST3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600,Weld-Neck RF, CS3 in. ANSI Class 600,Weld-Neck RF, SST

Code Opposite Side Support (Required for Model 46H only)

MSDCWMSDSW

Contoured Weld Fitting and Cap, 3 in., BW, CSContoured Weld Fitting and Cap, 3 in., BW, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DFF+45H 240 HAMH0 C0000 FADH0 FADC

MODEL DFF+45H/46H

Flow-427

Page 54: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODEL DFF+45M/46MModel Product Description

DFF+45MDFF+46M

Diamond II + Annubar® Primary Flow Element - Flanged, MonelDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, Monel

Code Line Size

100120140160180200240300360420480600720

10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HADM0HADMBHADMNHAMM0HAPM0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelIntegral, 3-Valve Manifold, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, Monel

HATM0HATMDHATMNHATMB

Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Monel

HVMM0HVDM0HVDMBHVDMNHVPM0

Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, MonelDirect Mount, 5-Valve Manifold, NACE, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, Monel

HVTM0HVTMBHVTMDHVTMN

Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel

HA2M0HA2MSHP2M0HAHM0HAHMS

Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, MonelAxial, Horizontal Line, ½ in. Socket Weld Ports, MonelParallel, Horizontal Line, ½—14 NPT, MonelAxial, HP, Horizontal Line, ½—14 NPT, MonelAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, Monel

HPVS0HPVSSHV2S0HV2SSHVHS0HVHSS

Remote Mount - Vertical LineParallel, Vertical Line, ½ in. Socket Weld Ports, SSTParallel, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½ in. Socket Weld Ports, SSTAxial, HP, Vertical Line, ½—14 NPT, SSTAxial, HP, Vertical Line, ½ in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP2C0SP2C0

Needle Valves - CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS

CP2S0SP2S0

Needle Valves - SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST

28

Page 55: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CP2M0Needle Valves - MonelNeedle Valve, Nipple, ½—14 NPT, Monel

CC2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS

CC2S0SC2S0SV2S0

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST

Code Sensor Flange

FFDM0FEDM0FCDM0FBDM0FADM0

3 in. ANSI Class 2500, RF, Monel3 in. ANSI Class 1500, RF, Monel3 in. ANSI Class 600, RF, Monel3 in. ANSI Class 300, RF, Monel3 in. ANSI Class 150, RF, Monel

Code Flanged Mount

FDDCFDDSFFDCFFDSFADCFADSFBDCFBDSFCDCFCDS

3 in. ANSI Class 900, Weld-Neck RF, CS3 in. ANSI Class 900, Weld-Neck RF, SST3 in. ANSI Class 2500, Weld-Neck RF, CS3 in. ANSI Class 2500, Weld-Neck RF, SST3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST

Code Opposite Side Support (Required for Model 46M only)

MSDCWMSDSW

Contoured Weld Fitting and Cap, 3 in., BW, CSContoured Weld Fitting and Cap, 3 in., BW, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DFF+45M 240 HAMM0 C0000 FADM0 FADC

MODEL DFF+45M/46M

Flow-429

Page 56: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

30

Page 57: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-431

Page 58: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

32

Page 59: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-433

Page 60: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Ordering Information—Model DPFMODELS DPF+15S/16S

Model Product Description

DPF+15SDPF+16S

Diamond II + Annubar® Primary Flow Element - Pak-Lok FlangedDiamond II + Annubar® Primary Flow Element - Pak-Lok Flanged with Opposite Side Support

Code Line Size

020025030035040050

2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)

Code Head Style

HVPS0Direct and Integral Mount Head - Vertical LineDirect Mount, No Manifold, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP2C0SP2C0CA2C0SA2C0

Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS

CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0

Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple,1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST

CC2C0SC2C0CB2C0SB2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT,CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CC2S0SC2S0CB2SSCC2SSSV2SSCB2S0SB2S0SV2S0

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST

34

Page 61: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Pak-Lok Sensor Flange

PA4C2PA4S2PB4C2PB4S2PC4C2PC4S2

Pak-Lok Flange, 1 in. ANSI Class 150, RF, CSPak-Lok Flange, 1 in. ANSI Class 150, RF, SSTPak-Lok Flange, 1 in. ANSI Class 300, RF, CSPak-Lok Flange, 1 in. ANSI Class 300, RF, SSTPak-Lok Flange, 1 in. ANSI Class 600, RF, CSPak-Lok Flange, 1 in. ANSI Class 600, RF, SST

Code Flanged Mounting

FA4CFA4SFB4CFB4SFC4CFC4S

1 in. ANSI Class 150, Weld-Neck RF, CS1 in. ANSI Class 150, Weld-Neck RF, SST1 in. ANSI Class 300, Weld-Neck RF, CS1 in. ANSI Class 300, Weld-Neck RF, SST1 in. ANSI Class 600, Weld-Neck RF, CS1 in. ANSI Class 600, Weld-Neck RF, SST

Code Opposite Side Support (Required for Model 16S only)

MS2C0MS2CWMS2S0MS2SW

Contoured Weld Fitting and Plug, 1/2—14 NPT, CSContoured Weld Fitting and Plug, 1/2 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1/2—14 NPT, SSTContoured Weld Fitting and Plug, 1/2 in. Socket Weld Ports, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXR

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZ

Lab Flow Calibration (Average K) (<10 in.)Special Calibration

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DPF+15S 020 HA2S0 CP2C0 PA4C2 FA4C

MODELS DPF+15S/16S

Flow-435

Page 62: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODELS DPF+25S/26SModel Product Description

DPF+25SDPF+26S

Diamond II + Annubar® Primary Flow Element - Pak-Lok FlangedDiamond II + Annubar®Primary Flow Element - Pak-Lok Flanged with Opposite Side Support

Code Line Size

040050060080100120140160180200240300360420

4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)

Code Head Style

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP2C0SP2C0CA2C0SA2C0

Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS

CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0

Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple,1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST

CC2C0SC2C0CB2C0SB2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT,CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CC2S0SC2S0CB2SSCC2SSSV2SSCB2S0SB2S0SV2S0

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST

36

Page 63: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Pak-lok Sensor Flange

PA6C4PA6S4PB6C4PB6S4PC6C4PC6S4

Pak-Lok Flange, 11/2 in. ANSI Class 150, RF, CSPak-Lok Flange, 11/2 in. ANSI Class 150, RF, SSTPak-Lok Flange, 11/2 in. ANSI Class 300, RF, CSPak-Lok Flange, 11/2 in. ANSI Class 300, RF, SSTPak-Lok Flange, 11/2 in. ANSI Class 600, RF, CSPak-Lok Flange, 11/2 in. ANSI Class 600, RF, SST

Code Flanged Mounting

FA6CFA6SFB6CFB6SFC6CFC6S

11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST11/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SST

Code Opposite Side Support (Required for Model 26S only)

MS4C0MS4CWMS4S0MS4SW

Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXRTRATRPTXATXP

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DPF+25S 040 HA2S0 CP2C0 PA6C4 FA6C

MODELS DPF+25S/26S

Flow-437

Page 64: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODELS DPF+35S/36SModel Product Description

DPF+35SDPF+36S

Diamond II + Annubar® Primary Flow Element - Pak-Lok FlangedDiamond II + Annubar® Primary Flow Element - Pak-Lok Flanged with Opposite Side Support

Code Line Size

080100120140160180200240300360420480600720

8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP2C0SP2C0CA2C0SA2C0

Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS

CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0

Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple,1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST

CC2C0SC2C0CB2C0SB2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT,CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CC2S0SC2S0CB2SSCC2SSSV2SSCB2S0SB2S0SV2S0

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST

38

Page 65: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Pak-Lok Sensor Flange

PA8C6PA8S6PB8C6PB8S6PC8C6PC8S6

Pak-Lok Flange, 2 in. ANSI Class 150, RF, CSPak-Lok Flange, 2 in. ANSI Class 150, RF, SSTPak-Lok Flange, 2 in. ANSI Class 300, RF, CSPak-Lok Flange, 2 in. ANSI Class 300, RF, SSTPak-Lok Flange, 2 in. ANSI Class 600, RF, CSPak-Lok Flange, 2 in. ANSI Class 600, RF, SST

Code Flanged Mount

FA8CFA8SFB8CFB8SFC8CFC8S

2 in. ANSI Class 150, Weld-Neck RF, CS2 in. ANSI Class 150, Weld-Neck RF, SST2 in. ANSI Class 300, Weld-Neck RF, CS2 in. ANSI Class 300, Weld-Neck RF, SST2 in. ANSI Class 600, Weld-Neck RF, CS2 in. ANSI Class 600, Weld-Neck RF, SST

Code Opposite Side Support (Required for Model 36S only)

MS6C0MS6CWMS6S0MS6SW

Contoured Weld Fitting and Plug, 11/2—11.5 NPT, CSContoured Weld Fitting and Plug, 11/2 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 11/2—11.5 NPT, SSTContoured Weld Fitting and Plug, 11/2 in. Socket Weld Ports, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXRTRATRPTXATXP

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DPF+35S 120 HA2S0 CP2C0 PA8C6 FA8C

MODELS DPF+35S/36S

Flow-439

Page 66: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODELS DPF+45S/46SModel Product Description

DPF+45SDPF+46S

Diamond II + Annubar® Primary Flow Element - Pak-Lok FlangedDiamond II + Annubar® Primary Flow Element - Pak-Lok Flanged with Opposite Side Support

Code Line Size

100120140160180200240300360420480600720

10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. (1520 mm)72 in. (1820 mm)

Code Head Style

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP2C0SP2C0CA2C0SA2C0

Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS

CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0

Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple,1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST

CC2C0SC2C0CB2C0SB2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT,CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CC2S0SC2S0CB2SSCC2SSSV2SSCB2S0SB2S0SV2S0

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST

40

Page 67: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Pak-Lok Sensor Flange

PADCDPADSDPBDCDPBDSDPCDCDPCDSD

Pak-Lok Flange, 3 in. ANSI Class 150, RF, CSPak-Lok Flange, 3 in. ANSI Class 150, RF, SSTPak-Lok Flange, 3 in. ANSI Class 300, RF, CSPak-Lok Flange, 3 in. ANSI Class 300, RF, SSTPak-Lok Flange, 3 in. ANSI Class 600, RF, CSPak-Lok Flange, 3 in. ANSI Class 600, RF, SST

Code Flanged Mount

FADCFADSFBDCFBDSFCDCFCDS

3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST

Code Opposite Side Support (Required for Model 46S only)

MSDCWMSDSW

Contoured Weld Fitting and Cap, 3 in., BW, CSContoured Weld Fitting and Cap, 3 in., BW, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXRTRATRPTXATXP

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DPF+45S 240 HA2S0 CP2C0 PADCD FADC

MODELS DPF+45S/46S

Flow-441

Page 68: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

42

Page 69: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-443

Page 70: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

44

Page 71: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-445

Page 72: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Ordering Information—Model DNTMODEL DNT+10S

Model Product Description

DNT+10S Diamond II + Annubar® Primary Flow Element - In-line Threaded

Code Line Size

005007010012015020

1/2 in. (12.5 mm)3/4 in. (19 mm)1 in. (25 mm)11/4 in. (31 mm)11/2 in. (37.5 mm)2 in. (50 mm)

Code Fittings

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HF1SSHM1S0

Remote MountFittings, 1/4 in. Socket Weld Ports, SSTFittings, 1/4 in., MNPT, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP1C0CP1S0SB1C0SB1S0SP1C0SP1S0

Needle Valve, Nipple, 1/4—18 NPT, CSNeedle Valve, Nipple, 1/4—18 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, SSTNeedle Valve, Nipple and Tee, 1/4—18 NPT, CSNeedle Valve, Nipple and Tee, 1/4—18 NPT, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXR

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP Primary

Code Optional Calibration

MZ

Lab Flow Calibration (Average K) (<10 in.)Special Calibration

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DNT+10S 010 HAMS0 HF1SS C0000

46

Page 73: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Ordering Information—Model DNFMODEL DNF+10S

Model Product Description

DNF+10S Diamond II + Annubar® Primary Flow Element - In-line Flanged

Code Line Size

005007010012015020

1/2 in. (12.5 mm)3/4 in. (19 mm)1 in. (25 mm)11/4 in. (31 mm)11/2 in. (37.5 mm)2 in. (50 mm)

Code Fittings

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HF1SSHM1S0

Remote MountFittings, 1/4 in. Socket Weld Ports, SSTFittings, 1/4 in. MNPT, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP1C0CP1S0SB1C0SB1S0SP1C0SP1S0

Needle Valve, Nipple, 1/4—18 NPT, CSNeedle Valve, Nipple, 1/4—18 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, SSTNeedle Valve, Nipple and Tee, 1/4—18 NPT, CSNeedle Valve, Nipple and Tee, 1/4—18 NPT, SST

Code Flanged Mount

FASFBSFCSFJSFLSFNS

ANSI Class 150, Weld-Neck RF, SSTANSI Class 300, Weld-Neck RF, SSTANSI Class 600, Weld-Neck RF, SSTDIN PN 16, SSTDIN PN 40, SSTDIN PN 100, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXR

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

BS

Lab Flow Calibration (Average K) (<10 in.)Special Calibration

Flow-447

Page 74: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

48

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DNF+10S 010 HAMS0 HF1SS C0000 FAS

MODEL DNF+10S

Page 75: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

-449

Diam

ond

II+An

nuba

Flow

MODEL DNF+10HModel Product Description

DNF+10H Diamond II + Annubar® Primary Flow Element - In-line Flanged

Code Line Size

005007010012015020

1/2 in. (12.5 mm)3/4 in. (19 mm)1 in. (25 mm)11/4 in. (31 mm)11/2 in. (37.5 mm2 in. (50 mm)

Code Fittings

HADH0HADHBHADHNHAPH0HAMH0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-CIntegral, 3-Valve Manifold, Horizontal Line, Hastelloy-C

HVDH0HVDHBHVDHNHVPH0HVMH0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-CIntegral, 3-Valve Manifold, Vertical Line, Hastelloy-C

HM1H0Remote MountFittings, 1/4 in., MNPT, Hastelloy-C

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP1C0CP1S0SB1C0SB1S0SP1C0SP1S0

Needle Valve, Nipple, 1/4—18 NPT, CSNeedle Valve, Nipple, 1/4—18 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, SSTNeedle Valve, Nipple and Tee, 1/4—18 NPT, CSNeedle Valve, Nipple and Tee, 1/4—18 NPT, SST

Code Flanged Mount

FAHFBHFCH

ANSI Class 150, Weld-Neck RF, Hastelloy-CANSI Class 300, Weld-Neck RF, Hastelloy-CANSI Class 600, Weld-Neck RF, Hastelloy-C

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXR

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZ

Lab Flow Calibration (Average K) (<10 in.)Special Calibration

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DNF+10H 010 HAMH0 C0000 FAH

Page 76: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODEL DNF+10MModel Product Description

DNF+10M Diamond II + Annubar® Primary Flow Element - In-line Flanged

Code Line Size

005007010012015020

1/2 in. (12.5 mm)3/4 in. (19 mm)1 in. (25 mm)11/4 in. (31 mm)11/2 in. (37.5 mm)2 in. (50 mm)

Code Fittings

HADM0HADMBHADMNHAMM0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelIntegral, with 3-Valve Manifold, Horizontal Line, Monel

HVDM0HVDMBHVDMNHVMM0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, MonelIntegral, with 3-Valve Manifold, Vertical Line, Monel

HM1M0CP1C0CP1S0SB1C0SB1S0SP1C0SP1S0

Remote MountFittings, 1/4 in. MNPT, MonelNeedle Valve, Nipple, 1/4—18 NPT, CSNeedle Valve, Nipple, 1/4—18 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, SSTNeedle Valve, Nipple and Tee, 1/4—18 NPT, CSNeedle Valve, Nipple and Tee, 1/4—18 NPT, SST

Code Flanged Mount

FAMFBMFCM

ANSI Class 150, Weld-Neck RF, MonelANSI Class 300, Weld-Neck RF, MonelANSI Class 600, Weld-Neck RF, Monel

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXR

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZ

Lab Flow Calibration (Average K) (<10 in.)Special Calibration

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DNF+10M 010 HAMM0 C0000 FAM

50

Page 77: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Ordering Information—Model DNWMODEL DNW+10S

Model Product Description

DNW+10S Diamond II + Annubar® Primary Flow Element - In-line Butt Weld

Code Line Size

005007010012015020

1/2 in. (12.5 mm)3/4 in. (19 mm)1 in. (25 mm)11/4 in. (31 mm)11/2 in. (37.5 mm)2 in. (50 mm)

Code Fittings

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LIneDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LIneDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Direct, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SST

HF1SSHM1S0

Remote MountFittings, 1/4 in. Socket Weld Ports, SSTFittings, 1/4 in., MNPT, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP1C0CP1S0SB1C0SB1S0SP1C0SP1S0

Needle Valve, Nipple, 1/4—18 NPT, CSNeedle Valve, Nipple, 1/4—18 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, SSTNeedle Valve, Nipple and Tee, 1/4—18 NPT, CSNeedle Valve, Nipple and Tee, 1/4—18 NPT, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXR

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP Primary

Code Optional Calibration

MZ

Lab Flow Calibration (Average K) (<10 in.)Special Calibration

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DNW+10S 010 HAMS0 C0000

Flow-451

Page 78: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

52

Page 79: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-453

Page 80: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

54

Page 81: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-455

Page 82: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Ordering Information—Model DMTMODEL DMT+15S

Model Product Description

DMT+15S Diamond II + Annubar® Primary Flow Element - Threaded Flo-Tap, Medium Pressure

Code Line Size

020025030035040050

2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)

Code Head Style

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valves - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

56

Page 83: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Packing Gland

GR3S0GR3C0GM3S0GM3C0

Graphite, 3/4—14 NPT, SSTGraphite, 3/4—14 NPT, CSUrethane, 3/4—14 NPT, SSTUrethane, 3/4—14 NPT, CS

Code Insert/Retract

IMRSIMRCIMDSIMDC

Manual, Single, SST RodManual, Single, CS RodWheel, Single, SST RodWheel, Single, CS Rod

Code Isolation Valves

VT3SGVT3SBVT3CGVT3CB

Gate Valve, 3/4—14 NPT, SSTBall Valve, 3/4—14 NPT, SSTGate Valve, 3/4—14 NPT, CSBall Valve, 3/4—14 NPT, CS

Code Mounting Hardware

MH3C0MH3S0

Weld Coupling and Nipple, 3/4—14 NPT, CSWeld Coupling and Nipple, 3/4—14 NPT, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXRTRATRPTXATXP

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZ

Lab Flow Calibration (Average K) (<10 in.)Special Calibration

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DMT+15S 020 HAMS0 C0000 GR350 IMRS VT3SG MH3C0

MODEL DMT+15S

Flow-457

Page 84: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODEL DMT+25SModel Product Description

DMT+25S Diamond II + Annubar® Primary Flow Element - Threaded Flo-Tap, Medium Pressure

Code Line Size

040050060080100120140160180200240300360420

4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)

Code Head Style

HADS0HADSBHADSNHAMS0HAPS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST

HATSNHATSBHATSDHATS0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HVTSBHVTSDHVTSNHVTS0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

58

Page 85: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Packing Gland

GR5S0GR5C0GM5S0GM5C0

Graphite, 11/4—11.5 NPT, SSTGraphite, 11/4—11.5 NPT, CSUrethane, 11/4—11.5 NPT, SSTUrethane, 11/4—11.5 NPT, CS

Code Insert/Retract

IMRSIMRCIMDSIMDC

Manual, Single, SST RodManual, Single, CS RodWheel, Single, SST RodWheel, Single, CS Rod

Code Isolation Valve

VT5SGVT5SBVT5CGVT5CB

Gate Valve, 11/4—11.5 NPT, SSTBall Valve, 11/4—11.5 NPT, SSTGate Valve, 11/4—11.5 NPT, CSBall Valve, 11/4—11.5 NPT, CS

Code Mounting Hardware

MH5C0MH5S0

Weld Coupling and Nipple, 11/4—11.5 NPT, CSWeld Coupling and Nipple, 11/4—11.5 NPT, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXRTRATRPTXATXP

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

MODEL DMT+25S

Flow-459

Page 86: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DMT+25S 040 HAMS0 C0000 GR5S0 IMRS VT5SG MH5C0

MODEL DMT+25S

60

Page 87: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

MODEL DMT+35SModel Product Description

DMT+35S Diamond II + Annubar® Primary Flow Element - Threaded Flo-Tap, Medium Pressure

Code Line Size

080100120140160180200240300360420480600720

8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HADS0HADSBHADSNHAMS0HAPS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST

HATSNHATSBHATSDHATS0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HVTSBHVTSDHVTSNHVTS0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

Flow-461

Page 88: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Instrument Connections (Continued)

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Packing Gland

GR8S0GR8C0GM8S0GM8C0

Graphite, 2—11.5 NPT, SSTGraphite, 2—11.5 NPT, CSUrethane, 2—11.5 NPT, SSTUrethane, 2—11.5 NPT, CS

Code Insert/Retract

IMRSIMRCIMDSIMDC

Manual, Single, SST RodManual, Single, CS RodWheel, Single, SST RodWheel, Single, CS Rod

Code Isolation Valves

VT8SGVT8SBVT8CGVT8CB

Gate Valve, 2—11.5 NPT, SSTBall Valve, 2—11.5 NPT, SSTGate Valve, 2—11.5 NPT, CSBall Valve, 2—11.5 NPT, CS

Code Mounting Hardware

MH8C0MH8S0

Weld Coupling and Nipple, 2—11.5 NPT, CSWeld Coupling and Nipple, 2—11.5 NPT, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXRTRATRPTXATXP

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

MODEL DMT+35S

62

Page 89: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DMT+35S 240 HAMS0 C0000 GR8S0 IMDS VT8SG MH8C0

MODEL DMT+35S

Flow-463

Page 90: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

64

Page 91: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-465

Page 92: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

66

Page 93: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-467

Page 94: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

68

Page 95: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Ordering Information—Model DHTMODEL DHT+15S

Model Product Description

DHT+15S Diamond II + Annubar® Primary Flow Element - Threaded Flo-Tap, High Pressure

Code Line Size

020025030035040050

2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)

Code Head Style

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valves - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

CB2C0CC2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS

SB2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

Flow-469

Page 96: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Instrument Connections (Continued)

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Packing Gland

GV3S0GV3C0GH3S0GH3C0

Graphite, 3/4—14 NPT, SSTGraphite, 3/4—14 NPT, CSUrethane, 3/4—14 NPT, SSTUrethane, 3/4—14 NPT, CS

Code Insert/Retract

IHRSIHRC

Manual, Dual, SST RodsManual, Dual, CS Rods

Code Isolation Valves

VT3SGVT3SBVT3CGVT3CB

Gate Valve, 2—11.5 NPT, SSTBall Valve, 2—11.5 NPT, SSTGate Valve, 2—11.5 NPT, CSBall Valve, 2—11.5 NPT, CS

Code Mounting Hardware

MH3C0MH3S0

Weld Coupling and Nipple, 3/4—14 NPT, CSWeld Coupling and Nipple, 3/4—14 NPT, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXR

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZ

Lab Flow Calibration (Average K) (<10 in.)Special Calibration

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DHT+15S 020 HAMS0 C0000 GV3S0 IHRS VT3SG MH3C0

MODEL DHT+15S

70

Page 97: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

MODEL DHT+25SModel Product Description

DHT+25S Diamond II + Annubar® Primary Flow Element - Threaded Flo-Tap, High Pressure

Code Line Size

040050060080100120140160180200240300360420

4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)

Code Head Style

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST

HATSBHATSDHATSNHATS0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HVTSBHVTSDHVTSNHVTS0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

Flow-471

Page 98: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Instrument Connections (Continued)

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valves - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Packing Gland

GV5S0GV5C0GH5S0GH5C0

Graphite, 11/4—11.5 NPT, SSTGraphite, 11/4—11.5 NPT, CSUrethane, 11/4—11.5 NPT, SSTUrethane, 11/4—11.5 NPT, CS

Code Insert/Retract

IHRSIHRCIHDS

Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST Rods

Code Isolation Valves

VT5SGVT5SBVT5CGVT5CB

Gate Valve, 11/4—11.5 NPT, SSTBall Valve, 11/4—11.5 NPT, SSTGate Valve, 11/4—11.5 NPT, CSBall Valve, 11/4—11.5 NPT, CS

Code Mounting Hardware

MH5C0MH5S0

Weld Coupling and Nipple, 11/4—11.5 NPT, CSWeld Coupling and Nipple, 11/4—11.5 NPT, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXRTRATRPTXATXP

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

MODEL DHT+25S

72

Page 99: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DHT+25S 040 HAMS0 C0000 GV5S0 IHRS VT5SG MH5C0

MODEL DHT+25S

Flow-473

Page 100: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODEL DHT+35SModel Product Description

DHT+35S Diamond II + Annubar® Primary Flow Element- Threaded Flo-Tap, High Pressure

Code Line Size

080100120140160180200240300360420480600720

8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST

HATSBHATSDHATSNHATS0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HVTSBHVTSDHVTSNHVTS0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

74

Page 101: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valves - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Packing Gland

GV8S0GV8C0GH8S0GH8C0

Graphite, 2—11.5 NPT, SSTGraphite, 2—11.5 NPT, CSUrethane, 2—11.5 NPT, SSTUrethane, 2—11.5 NPT, CS

Code Insert/Retract

IHRSIHRCIHDS

Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST Rods

Code Isolation Valves

VT8SGVT8SBVT8CGVT8CB

Gate Valve, 2—11.5 NPT, SSTBall Valve, 2—11.5 NPT, SSTGate Valve, 2—11.5 NPT, CSBall Valve, 2—11.5 NPT, CS

Code Mounting Hardware

MH8C0MH8S0

Weld Coupling and Nipple, 2—11.5 NPT, CSWeld Coupling and Nipple, 2—11.5 NPT, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRRTXRTRATRPTXATXP

Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

MODEL DHT+35S

Flow-475

Page 102: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number: DHT+35S 120 HAMS0 C0000 GV8S0 IHDS VT8SG MH8C0

MODEL DHT+35S

76

Page 103: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-477

Page 104: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

78

Page 105: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-479

Page 106: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

80

Page 107: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-481

Page 108: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Ordering Information—Model DHFMODEL DHF+15S

Model Product Description

DHF+15S Diamond II Annubar® Primary Flow Element - Flanged Flo-Tap

Code Line Size

020025030035040050

2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)

Code Head Style

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SST

Parallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

82

Page 109: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Packing Gland

GV4SCGV4SBGV4SAGH4SCGH4SBGH4SA

Graphite, 1 in. ANSI Class 600, SSTGraphite, 1 in. ANSI Class 300, SSTGraphite, 1 in. ANSI Class 150, SSTUrethane, 1 in. ANSI Class 600, SSTUrethane, 1 in. ANSI Class 300, SSTUrethane, 1 in. ANSI Class 150, SST

Code Insert/Retract

IHRSIHRC

Manual, Dual, SST RodsManual, Dual, CS Rods

Code Isolation Valves

VC4CGVB4CGVA4CG

Gate Valve - CSGate Valve, 1 in. ANSI Class 600, CSGate Valve, 1 in. ANSI Class 300, CSGate Valve, 1 in. ANSI Class 150, CS

VC4SGVB4SGVA4SG

Gate Valve - SSTGate Valve, 1 in. ANSI Class 600, SSTGate Valve, 1 in. ANSI Class 300, SSTGate Valve, 1 in. ANSI Class 150, SST

VB4CBVA4CB

Ball Valve - CSBall Valve, 1 in. ANSI Class 300, CSBall Valve, 1 in. ANSI Class 150, CS

VB4SBVA4SB

Ball Valve - SSTBall Valve, 1 in. ANSI Class 300, SSTBall Valve, 1 in. ANSI Class 150, SST

Code Flanged Mount

FJMCFJMSFLMCFLMSFNMCFNMSFA4CFA4SFB4CFB4SFC4CFC4S

DIN 25 PN 16, CSDIN 25 PN 16, 316SSTDIN 25 PN 40, CSDIN 25 PN 40, 316SSTDIN 25 PN 100, CSDIN 25 PN 100, 316SST1 in. ANSI Class 150, Weld-Neck RF, CS1 in. ANSI Class 150, Weld-Neck RF, SST1 in. ANSI Class 300, Weld-Neck RF, CS1 in. ANSI Class 300, Weld-Neck RF, SST1 in. ANSI Class 600, Weld-Neck RF, CS1 in. ANSI Class 600, Weld-Neck RF, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZ

Lab Flow Calibration (Average K) (<10 in.)Special Calibration

MODEL DHF+15S

Flow-483

Page 110: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Optional Quality Assurance

QA1Q21Q23Q29QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91ASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DHF+15S 020 HAMS0 C0000 GV4SA IHRS VA4SG FA4C

MODEL DHF+15S

84

Page 111: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

MODEL DHF+25SModel Product Description

DHF+25S Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap

Code Line Size

040050060080100120140160180200240300360420

4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)

Code Head Style

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST

HATSBHATSDHATSNHATS0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST

HVTSBHVTSDHVTSNHVTS0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST

HA2S0HA2SSHAHS0HAHSSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTAxial, HP, Horizontal Line, 1/2—14 NPT, SSTAxial, HP, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line,1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SSHVHS0HVHSS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SSTAxial, HP, Vertical Line, 1/2—14 NPT, SSTAxial, HP, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

Flow-485

Page 112: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Instrument Connections (Continued)

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Packing Gland

GV6SCGV6SBGV6SAGH6SCGH6SBGH6SA

Graphite, 11/2 in. ANSI Class 600, SSTGraphite, 11/2 in. ANSI Class 300, SSTGraphite, 11/2 in. ANSI Class 150, SSTUrethane, 11/2 in. ANSI Class 600, SSTUrethane, 11/2 in. ANSI Class 300, SSTUrethane, 11/2 in. ANSI Class 150, SST

Code Insert/Retract

IHRSIHRCIHDSIHDC

Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods

Code Isolation Valves

VC6CGVB6CGVA6CG

Gate Valve - CSGate Valve, 11/2 in. ANSI Class 600, CSGate Valve, 11/2 in. ANSI Class 300, CSGate Valve, 11/2 in. ANSI Class 150, CS

VC6SGVB6SGVA6SG

Gate Valve - SSTGate Valve, 11/2 in. ANSI Class 600, SSTGate Valve, 11/2 in. ANSI Class 300, SSTGate Valve, 11/2 in. ANSI Class 150, SST

VB6CBVA6SB

Ball Valve - CSBall Valve, 11/2 in. ANSI Class 300, CSBall Valve, 11/2 in. ANSI Class 150, SST

VB6SBVA6SB

Ball Valve - SSTBall Valve, 11/2 in. ANSI Class 300, SSTBall Valve, 11/2 in. ANSI Class 150, SST

Code Flanged Mount

FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8S

11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST11/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500, Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SST

MODEL DHF+25S

86

Page 113: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DHF+25S 040 HAMS0 C0000 GV4SA IHRC VA6CG FA6C

MODEL DHF+25S

Flow-487

Page 114: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODEL DHF+25HModel Product Description

DHF+25H Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap

Code Line Size

040050060080100120140160180200240300360420

4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)

Code Head Style

HADH0HADHBHADHNHAPH0HAMH0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-CIntegral, with 3-Valve Manifold, Horizontal Line, Hastelloy-C

HATHDHATHNHATHBHATH0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, Hastelloy-CIntegral, with 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C

HVDH0HVDHBHVDHNHVPH0HVMH0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-CIntegral, with 3-Valve Manifold, Vertical Line, Hastelloy-C

HVTHBHVTHDHVTHNHVTH0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-CIntegral, with 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C

HA2H0HA2HSHAHH0

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, Hastelloy-CAxial, Horizontal Line, 1/2 in. Socket Weld Ports, Hastelloy-CAxial, HP, Horizontal Line, 1/2—14 NPT, Hastelloy-C

HAHHSHP2H0

Remote Mount - Horizontal LineAxial, HP, Horizontal Line, 1/2 in. Socket Weld Ports, Hastelloy-CParallel, Horizontal Line, 1/2—14 NPT, Hastelloy-C

HPVH0HV2H0HVHH0HVHHS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2—14 NPT, Hastelloy-CAxial, Vertical Line, 1/2—14 NPT, Hastelloy-CAxial, HP, Vertical Line, 1/2—14 NPT, Hastelloy-CAxial, HP, Vertical Line, 1/2 in. Socket Weld Ports, Hastelloy-C

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

CA2S0CP2S0SA2S0SP2S0

Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SST

88

Page 115: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CC2S0SB2S0SC2S0SV2S0

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST

CA2H0CP2H0

Needle Valve - Hastelloy-CNeedle Valve, Elbow, 1/2—14 NPT, Hastelloy-CNeedle Valve, Nipple, 1/2—14 NPT, Hastelloy-C

Code Packing Glands

GV6HCGV6HBGV6HA

Graphite, 11/2 in. ANSI Class 600, Hastelloy-CGraphite, 11/2 in. ANSI Class 300, Hastelloy-CGraphite, 11/2 in. ANSI Class 150, Hastelloy-C

Code Insert/Retract

IHRSIHRCIHDSIHDC

Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods

Code Isolation Valves

VC6CGVB6CGVA6CG

Gate Valve - CSGate Valve, 11/2 in. ANSI Class 600, CSGate Valve, 11/2 in. ANSI Class 300, CSGate Valve, 11/2 in. ANSI Class 150, CS

VC6SGVB6SGVA6SG

Gate Valve - SSTGate Valve, 11/2 in. ANSI Class 600, SSTGate Valve, 11/2 in. ANSI Class 300, SSTGate Valve, 11/2 in. ANSI Class 150, SST

VB6CBVA6CB

Ball Valve - CSBall Valve, 11/2 in. ANSI Class 300, CSBall Valve, 11/2 in. ANSI Class 150, CS

VB6SBVA6SB

Ball Valve - SSTBall Valve, 11/2 in. ANSI Class 300, SSTBall Valve, 11/2 in. ANSI Class 150, SST

Code Flanged Mount

FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8S

11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST1 1/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500, Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

MODEL DHF+25H

Flow-489

Page 116: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DHF+25H 040 HAMH0 C0000 GV6HA IHRS VA6SG FA6C

MODEL DHF+25H

90

Page 117: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

MODEL DHF + 25MModel Product Description

DHF+25M Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap

Code Line Size

040050060080100120140160180200240300360420

4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)

Code Head Style

HADM0HADMBHADMNHAPM0HAMM0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, MonelIntegral, with 3-Valve Manifold, Horizontal Line, Monel

HATMDHATMNHATMBHATM0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, MonelIntegral, with 3-Valve Manifold, RTD, Horizontal Line, Monel

HVDM0HVDMBHVDMNHVPM0HVMM0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, MonelIntegral, with 3-Valve Manifold, Vertical Line, Monel

HVTMBHVTMDHVTMNHVTM0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, MonelIntegral, with 3-Valve Manifold, RTD, Vertical Line, Monel

HA2M0HA2MSHAHM0HAHMSHP2M0

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, MonelAxial, Horizontal Line, 1/2 in. Socket Weld Ports, MonelAxial, HP, Horizontal Line, 1/2—14 NPT, MonelAxial, HP, Horizontal Line, 1/2 in. Socket Weld Ports, MonelParallel, Horizontal Line, 1/2—14 NPT, Monel

HPVM0HV2M0HV2MSHVHM0HVHMS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2—14 NPT, MonelAxial, Vertical Line, 1/2—14 NPT, MonelAxial, Vertical Line, 1/2 in. Socket Weld Ports, MonelAxial, HP, Vertical Line, 1/2—14 NPT, MonelAxial, HP, Vertical Line, 1/2 in. Socket Weld Ports, Monel

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

Flow-491

Page 118: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Instrument Connections (Continued)

CA2S0CP2S0SA2S0SP2S0

Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SST

CA2M0CP2M0

Needle Valve - MonelNeedle Valve, Elbow, 1/2—14 NPT, MonelNeedle Valve, Nipple, 1/2—14 NPT, Monel

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CC2S0SB2S0SC2S0SV2S0

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST

Code Packing Glands

GV6MCGV6MBGV6MA

Graphite, 11/2 in. ANSI Class 600, MonelGraphite, 11/2 in. ANSI Class 300, MonelGraphite, 11/2 in. ANSI Class 150, Monel

Code Insert/Retract

IHRSIHRCIHDSIHDC

Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods

Code Isolation Valves

VC6CGVB6CGVA6CG

Gate Valve - CSGate Valve, 11/2 in. ANSI Class 600, CSGate Valve, 11/2 in. ANSI Class 300, CSGate Valve, 1 in. ANSI Class 150, CS

VC6SGVB6SGVA6SG

Gate Valve - SSTGate Valve, 11/2 in. ANSI Class 600, SSTGate Valve, 11/2 in. ANSI Class 300, SSTGate Valve, 11/2 in. ANSI Class 150, SST

VB6CBVA6CB

Ball Valve - CSBall Valve, 11/2 in. ANSI Class 300, CSBall Valve, 11/2 in. ANSI Class 150, CS

VB6SBVA6SB

Ball Valve - SSTBall Valve, 11/2 in. ANSI Class 300, SSTBall Valve, 11/2 in. ANSI Class 150, SST

Code Flanged Mount

FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8S

11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST11/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500, Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

MODEL DHF + 25M

92

Page 119: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DHF+25M 040 HAMM0 C0000 GV6MA IHRS VA6SG FA6C

MODEL DHF + 25M

Flow-493

Page 120: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

MODEL DHF+35SModel Product Description

DHF+35S Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap

Code Line Size

080100120140160180200240300360420480600720

8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SST

HATSBHATSDHATSNHATS0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SST

HVTSBHVTSDHVTSNHVTS0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, 3-Valve Manifold, RTD, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SST

Parallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

94

Page 121: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS

Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in., Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Packing Glands

GV8SCGV8SBGV8SAGH8SCGH8SBGH8SA

Graphite, 2 in. ANSI Class 600, SSTGraphite, 2 in. ANSI Class 300, SSTGraphite, 2 in. ANSI Class 150, SSTUrethane, 2 in. ANSI Class 600, SSTUrethane, 2 in. ANSI Class 300, SSTUrethane, 2 in. ANSI Class 150, SST

Code Insert/Retract

IHRSIHRCIHDSIHDC

Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods

Code Isolation Valve

VB8CGVA8CG

Gate Valve - CSGate Valve, 2 in. ANSI Class 300, CSGate Valve, 2 in. ANSI Class 150, CS

VB8SGVA8SG

Gate Valve - SSTGate Valve, 2 in. ANSI Class 300, SSTGate Valve, 2 in. ANSI Class 150, SST

VB8CBVA8CB

Ball Valve - CSBall Valve, 2 in. ANSI Class 300, CSBall Valve, 2 in. ANSI Class 150, CS

VB8SBVA8SB

Ball Valve - SSTBall Valve, 2 in. ANSI Class 300, SSTBall Valve, 2 in. ANSI Class 150, SST

Code Flanged Mount

FA8CFA8SFB8CFB8SFC8CFC8S

2 in. ANSI Class 150, Weld-Neck RF, CS2 in. ANSI Class 150, Weld-Neck RF, SST2 in. ANSI Class 300, Weld-Neck RF, CS2 in. ANSI Class 300, Weld-Neck RF, SST2 in. ANSI Class 600, Weld-Neck RF, CS2 in. ANSI Class 600, Weld-Neck RF, SST

MODEL DHF+35S

Flow-495

Page 122: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DHF+35S 120 HAMS0 C0000 GV8SA IHDS VA8SG FA8C

MODEL DHF+35S

96

Page 123: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

MODEL DHF+45SModel Product Description

DHF+45S Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap

Code Line Size

100120140160180200240300360420480600720

10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HADS0HADSBHADSNHAPS0HAMS0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SST

HATSBHATSDHATSNHATS0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SST

HVDS0HVDSBHVDSNHVPS0HVMS0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SST

HVTSBHVTSDHVTSNHVTS0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, 3-Valve Manifold, RTD, Vertical Line, SST

HA2S0HA2SSHP2S0HP2SS

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST

HPVS0HPVSSHV2S0HV2SS

Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CA2C0CP2C0SA2C0SP2C0

Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

Flow-497

Page 124: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-4

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Instrument Connections (Continued)

CA2SSCA2S0CP2S0SA2S0SP2S0CP2SSSP2SS

Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

CB2C0CC2C0SB2C0SC2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

CB2S0CC2S0SB2S0SC2S0SV2S0CB2SSCC2SSSV2SS

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in.,Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST

Code Packing Glands

GVDHCGVDHBGVDHA

Graphite, 3 in. ANSI Class 600, Hastelloy-CGraphite, 3 in. ANSI Class 300, Hastelloy-CGraphite, 3 in. ANSI Class 150, Hastelloy-C

Code Insert/Retract

IHRSIHRCIHDSIHDC

Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods

Code Isolation Valve

VCDCGVBDCGVADCG

Gate Valve - CSGate Valve, 3 in. ANSI Class 600, CSGate Valve, 3 in. ANSI Class 300, CSGate Valve, 3 in. ANSI Class 150, CS

VCDSGVBDSGVADSG

Gate Valve - SSTGate Valve, 3 in. ANSI Class 600, SSTGate Valve, 3 in. ANSI Class 300, SSTGate Valve, 3 in. ANSI Class 150, SST

VBDCBVADCB

Ball Valve - CSBall Valve, 3 in. ANSI Class 300, CSBall Valve, 3 in. ANSI Class 150, CS

VBDSBVADSB

Ball Valve - SSTBall Valve, 3 in. ANSI Class 300, SSTBall Valve, 3 in. ANSI Class 150, SST

Code Flanged Mount

FADCFADSFBDCFBDSFCDCFCDS

3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

MODEL DHF+45S

98

Page 125: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DHF+45S 240 HAMS0 C0000 GVDHA IHDS VADSG FADC

MODEL DHF+45S

Flow-499

Page 126: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-5

Diamond II+ Annubar®

Diamond

II+Annubar®

MODEL DHF+45HModel Product Description

DHF+45H Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap

Code Line Size

100120140160180200240300360420480600720

10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)

Code Head Style

HADH0HADHBHADHNHAPH0HAMH0

Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1,Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-CIntegral, 3-Valve Manifold, Horizontal Line, Hastelloy-C

HATHDHATHNHATHBHATH0

Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Hastelloy-CIntegral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C

HVDH0HVDHBHVDHNHVPH0HVMH0

Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-CIntegral, 3-Valve Manifold, Vertical Line, Hastelloy-C

HVTHBHVTHDHVTHNHVTH0

Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, 5-Valve Manifold, TD, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-CIntegral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C

HA2H0HA2HSHP2H0

Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, Hastelloy-CAxial, Horizontal Line, 1/2 in. Socket Weld Ports, Hastelloy-CParallel, Horizontal Line, 1/2—14 NPT, Hastelloy-C

HPVH0HV2H0

Remote Mount - Vertical LineParallel, Vertical Line, 1/2—14 NPT, Hastelloy-CAxial, Vertical Line, 1/2—14 NPT, Hastelloy-C

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP2C0SP2C0

Needle Valves - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS

CP2S0SP2S0

Needle Valves - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SST

CP2H0Needle Valves - Hastelloy-CNeedle Valve, Nipple, 1/2—14 NPT, Hastelloy-C

CC2C0SC2C0SV2C0

Gate Valves - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

00

Page 127: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Code Instrument Connections (Continued)

CC2S0SC2S0SV2S0

Gate Valves - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST

Code Packing Glands

GVDHCGVDHBGVDHA

Graphite, 3 in. ANSI Class 600, Hastelloy-CGraphite, 3 in. ANSI Class 300, Hastelloy-CGraphite, 3 in. ANSI Class 150, Hastelloy-C

Code Insert/Retract

IHRSIHRCIHDSIHDC

Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods

Code Isolation Valve

VCDCGVBDCGVADCG

Gate Valve - CSGate Valve, 3 in. ANSI Class 600, CSGate Valve, 3 in. ANSI Class 300, CSGate Valve, 3 in. ANSI Class 150, CS

VCDSGVBDSGVADSG

Gate Valve - SSTGate Valve, 3 in. ANSI Class 600, SSTGate Valve, 3 in. ANSI Class 300, SSTGate Valve, 3 in. ANSI Class 150, SST

VBDCBVADCB

Ball Valve - CSBall Valve, 3 in. ANSI Class 300, CSBall Valve, 3 in. ANSI Class 150, CS

VBDSBVADSB

Ball Valve - SSTBall Valve, 3 in. ANSI Class 300, SSTBall Valve, 3 in. ANSI Class 150, SST

Code Flanged Mount

FADCFADSFBDCFBDSFCDCFCDS

3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

MODEL DHF+45H

Flow-501

Page 128: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-5

Diamond II+ Annubar®

Diamond

II+Annubar®

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DHF+45H 240 HAMH0 C0000 GVDHA IHDS VADSG FADC

MODEL DHF+45H

02

Page 129: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Model DHF+45MModel Product Description

DHF+45M Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap

Code Line Size

100120140160180200240300360420480600720

10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. (1520 mm)72 in. (1820 mm)

Code Head Style

HADM0HADMBHADMNHAPM0HAMM0

Direct and Integral Mounted Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, MonelIntegral, 3-Valve Manifold, Horizontal Line, Monel

HATMDHATMNHATMBHATM0

Direct and Integral Mounted Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, MonelIntegral, 3-Valve Manifold, RTD, Horizontal Line, Monel

HVDM0HVDMBHVDMNHVPM0HVTM0

Direct and Integral Mounted Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, MonelDirect Mount, 5-Valve Manifold, NACE, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, MonelIntegral, 3-Valve Manifold, RTD, Vertical Line, Monel

HVTMBHVTMDHVTMNHVMM0

Direct and Integral Mounted Heads - Vertical Line with RTDDirect Mount, 5-Valve Manifold, TD, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, MonelIntegral, 3-Valve Manifold, RTD, Vertical Line, Monel

HA2M0HA2MSHP2M0

Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, MonelAxial, Horizontal Line, ½ in. Socket Weld Ports, MonelParallel, Horizontal Line, ½—14 NPT, Monel

HPVM0HV2M0HV2MS

Remote Mount - Vertical LineParallel, Vertical Line, ½—14 NPT, MonelAxial, Vertical Line, ½—14 NPT, MonelAxial, Vertical Line, ½ in. Socket Weld Ports, Monel

Code Instrument Connections

C0000S0000

Eliminate Instrument Connection Assembly (For Use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)

CP2C0SP2C0

Needle Valves - CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS

CP2S0SP2S0

Needle Valve - SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST

CP2M0Needle Valve - MonelNeedle Valve, Nipple, ½—14 NPT, Monel

CC2C0SC2C0SV2C0

Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS

CC2S0SC2S0SV2S0

Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST

Flow-503

Page 130: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diamond II+ Annubar®

Flow-5

Diamond

II+Annubar®

Code Packing Glands

GVDMCGVDMBGVDMA

Graphite, 3 in. ANSI Class 600, MonelGraphite, 3 in. ANSI Class 300, MonelGraphite, 3 in. ANSI Class 150, Monel

Code Insert/Retract

IHRSIHRCIHDSIHDC

Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods

Code Isolation Valve

VCDCGVBDCGVADCG

Gate Valve - CSGate Valve, 3 in. ANSI Class 600, CSGate Valve, 3 in. ANSI Class 300, CSGate Valve, 3 in. ANSI Class 150, CS

VCDSGVBDSGVADSG

Gate Valve - SSTGate Valve, 3 in. ANSI Class 600, SSTGate Valve, 3 in. ANSI Class 300, SSTGate Valve, 3 in. ANSI Class 150, SST

VBDCBVADCB

Ball Valve - CSBall Valve, 3 in. ANSI Class 300, CSBall Valve, 3 in. ANSI Class 150, CS

VBDSBVADSB

Ball Valve - SSTBall Valve, 3 in. ANSI Class 300, SSTBall Valve, 3 in. ANSI Class 150, SST

Code Flanged Mount

FADCFADSFBDCFBDSFCDCFCDS

3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST

Code Optional Temperature Sensors (For Use with Remote Mount Head Styles)

TRATRPTXATXPTRRTXR

Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof

Code Optional Special Assembly

S4 Factory Assembly of DP Transmitter to DP primary

Code Optional Calibration

MZOQSUWY

Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1Q21Q23Q29QJ2QM2QT1QT2QT8

Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046

Typical Model Number DHF+45M 240 HAMM0 C0000 GVDMA IHDS VADSG FADC

Model DHF+45M

04

Page 131: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-505

Page 132: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-5

Diamond II+ Annubar®

Diamond

II+Annubar®

06

Page 133: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Diam

ond

II+An

nuba

Rosemount Inc.

Flow-507

Page 134: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-5

Diamond II+ Annubar®

Diamond

II+Annubar®

08

Page 135: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Rosemount Inc.

Diam

ond

II+An

nuba

Specifications

FUNCTIONAL SPECIFICATIONS

Service

Liquid, gas, and steam applications.

Pipe Sizes

½ in. to 72 in. (12 mm to 1820 mm).

Flow Sensor Sizes (SST)

TABLE 3. Flow Sensor Sizes (SST).

Flow Sensor Sizes(Hastelloy-C and Monel)

TABLE 4. Flow Sensor Sizes (Hastelloy—C and Monel).

Operating Process Temperature LimitsIntegral head style: -40 °F to 500 °F (-40 °C to 454 °C).

For HATSB, HVTSB, HADSB, and HVDSB head styles and regular flanged, Flo-Tap models: -40 °F to 750 °F (-40 °C to 398 °C).

Remote mount (SST and Monel):-40 °F to 850 °F (-40 °C to 454 °C).

Remote mount (Hastelloy-C):-40 °F to 900 °F (-40 °C to 482 °C).

Remote mount (Hastelloy-C) with remote temperature sensor :-40 °F to 1200 °F (-40 °C to 649 °C).

Pressure Limits

0–1440 psig (100 barg) @ 100 °F (37.8 °C).

Contact the factory for higher pressures.

PERFORMANCE SPECIFICATIONS

Accuracy

±1% of flow coefficient.

When used in closed loop–control applications, higher damping values are recommended.

Repeatability

±0.1%.

TABLE 5. Model Minimum Reynold’s Numbers.

See the Annubar Primary Flow Element Handbook for detailed information (page Flow-375).

May be protected by one or more of the following U.S. Patent Nos.4,559,836; 4,717,159;5,710,370; 5,773,726; 4,633, 713; and various foreign patents. Other foreign patents issuedand pending.

Rosemount, the Rosemount logotype, PlantWeb, Fisher-Rosemount, and Managing theProcess Better are marks of one of the Fisher-Rosemount group of companies. Coplanar,MV, and Multivariable are trademarks of Rosemount Inc.

Mass ProBar, ProBar, and Annubar are registered trademarks of Dieterich Standard Inc.

HART is a registered trademark of the HART Communications Foundation.

Monel is a registered trademark of International Nickel Co.

Teflon is a registered trademark of E. I. du Pont de Nemours & Co.

Hastelloy C and Hastelloy C-276 are registered trademarks of Cabot Corp.

Windows is a trademark of Microsoft Corp.

All other marks are the property of their respective owners.

Sensor # For Line Sizes

10 ½ in. to 2 in. (12.5 mm to 50 mm)

15/16 2 in. to 5 in. (50 mm to 125 mm)

25/26 4 in. to 42in. (100 mm to 1066 mm)

35/36 8 in. to 72 in. (200 mm to 1820 mm)

45/46 10 in. to 72 in. (250 mm to 1820 mm)

Sensor # For Line Sizes

10 ½ in. to 2 in. (12.5 mm to 50 mm)

25/26 4 in. to 42 in. (100 mm to 1066 mm)

45/46 10 in. to 72 in. (250 mm to 1820 mm)

Model Minimum Reynold’s Number (Re rod )

10 2300

½ in. lines 4000

15/16 6500

25/26 10000

35/36 15000

45/46 25000

Where: ρ = fluid density in lbm/ft3

d = probe width in feetV = velocity of fluid in ft/secµ = fluid viscosity in lbm/ft–sec

Rerod = dVρ

µ

Flow-509

Page 136: Diamond II+Annubar Primary Flow Element - ÅF · PDF fileDiamond II+Annubar® Primary Flow Element ... Calibration results for water ... The simplest design for an averaging pitot

Flow-5

Diamond II+ Annubar®

Diamond

II+Annubar®

PHYSICAL SPECIFICATIONS

Sensor

316/316L SST.

Hastelloy—C (flanged models, sensors 10, 25/26, and 45/46).

Monel (flanged models, sensors 10, 25/26, and 45/46).

Integral Valve and Direct Mounts HeadStyles (3 and 5 Valve)

Material

316 SST (Hastelloy—C and Monel options).

O–Rings

Teflon® (Grafoil above 500 °F [260 °C]).

Bolts

316 SST.

Flange, Isolation Valves

316L SST. Flange pressure limits are per ANSI B16.5 for 316 SST and material per SA 182. Flange face finish ANSI B16.5, 125 to 250 RMS.

Packing Gland Assembly

Packing Gland: 316 SST.

Packing: Graphite AFP–127.

Flange Mounting Hardware

(Includes nuts, bolts, and gasket) 316 SST or CS.

Temperature Options

Integral RTD: 100 Ω Platinum RTD.

Remote: 100 Ω Platinum RTD, spring loaded with½ in.—14 NPT nipple and union.

Thermowell: ½ in. × ½ in.—14 NPT, 316 SST with ½ in. CS weld couplet, u = 2½ in.

00813-0100-4760 Rev. DA 11/98

¢00813-0100-4762+¤

PR

INTED

INU.S. A.

Dieterich Standard Inc.5601 North 71st StreetBoulder, CO 80301Tel (303) 530-9600Fax (303) 530-7064

© 1998 Rosemount Inc.http://www.rosemount.com

Fisher-RosemountSingapore Pte Ltd.1 Pandan CrescentSingapore 128461Tel (65) 777-8211Fax (65) 777-0947Tlx RS 61117 FRSPL

Fisher-Rosemount LimitedHeath Place Bognor RegisWest Sussex PO22 9SHEnglandTel 44 (1243) 863 121Fax 44 (1243) 867 5541

Rosemount Inc.8200 Market BoulevardChanhassen, MN 55317 USATel 1-800-999-9307Telex 4310012Fax (612) 949-7001

10