DFX-MM series
High-end Ultrasonic Flow Meter for Liquid Hydrocarbons Custody Transfer
02/1
0/20
09 P
age1
L002
G D
FX-M
M lea
flet
32 beams for ultimate performance
02/1
0/20
09 P
age2
L002
G D
FX-M
M lea
flet
DFX-MMFeatures & benefits
PerformanceA master meter class UFM exceeding current
standards from Naphtas / Condensates / Liquid
gases to Heavy crudes / Fuel oils
Superior linearity and repeatability thanks to
unequalled spatial coverage and ultra-fast
scanning rate
Compliant with OIML R117-1 class 0.3, M.I.D.
2004/22/EC and API MPMS Ch5.8
Truly Provable with standard turbine prover loops
Design32-beams protected design
Transit time operating principle
Unique 22.5° axial symetry with excentration
design for really much less sensitivity to flow
profile disturbances
Small volume transducers cavities minimize the
scaling effects and avoid gas pockets
InstallationReduced straight runs installation possible
Compact integrated electronics for easy site
commissioning and start-up
CommunicationHigh integration to common flow computers.
Secure ethernet communication
HTML-based configuration and auditing software
with open communication protocol for on-line
remote technical support
Powerfull flow imaging capability
ServiceUltrasonic paths redundancy allows scheduled
site maintenance and downtime reduction.
Transducers exchangeable without recalibrating
the meter
DFX-MMApplications
FSO's & FPSO's custody transfer (Crude oil)
On and Offshore allocation metering (Crude
oil, condensates)
Pipeline metering stations (Crude Oil, Refined
products)
Tanker loading / offloading terminals (Crude
Oil, Refined products, Petrochemicals)
Storage management (Crude Oil, Refined
products, Petrochemicals)
DFX-MMPerformance comparison with other UFM's
DFX-MMProving volume comparison with other UFM's
1 000 10 000 100 000 1 000 0000,980
0,985
0,990
0,995
1,000
1,005
1,010
1,015
1,020
Typical Meter Factor v/s Reynolds Number for different UFM patterns.
32-beam s DFX m eter8'' 4-beam s parallel UFM
8'' Star UFM8" Helical turbine m eter
Reynolds Number
Mete
r Fa
ctor
DFX-MM is the only UFM with a stable meter factor over a wide Reynolds range and therefore is ideal for multiproduct pipelines and crude oils with viscosity variation.
DFX-MM requires much less prove volume than other UFM's and therefore is truly provable with standard turbine prover loops where other UFM's definitively should be proved by master meter method.
2 4 6 8 10 12 14 16 18 20 22 24
1
10
100
2
4
711
1621
2835
4463
5
12
2132
4763
83Recommended Prove Volume v/s Meter S ize
API MPMS cha pte r 5-8 recomme nda tionConve ntiona l UFM #1 Conve ntiona l UFM #2DFX-MM proving requirements
Meter Size ( inch )
Pro
ver Volu
me ( m
3 )
02/1
0/20
09 P
age3
L002
G D
FX-M
M lea
flet
DFX-MMCalibration curves
DFX-MM sustains a premium +/- 0.10 % accuracy with a constant K-Factor over a wide range of viscosities and of operating conditions.
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 20000,990
0,991
0,992
0,993
0,994
0,995
0,996
0,997
0,998
0,999
1,000
1,001
1,002
1,003
1,004
1,005
1,006
1,007
1,008
1,009
1,010
DFX-MM 08'' : baselinesFlowstraightener 7 D long, ball prover volume 10m3
JET FUEL 5,0 cst 17 °C Water 6%JET FUEL 4,5 cst 24 °CJET FUEL 4,5 cst 24 °C Ball valve 40% closedGASOIL 8,4 cst 18 °CGASOIL 8,4 cst 18 °C Ball valve 40% closedOIL 15,5 cst 22 °COIL 62,0 cst 16 °CSame oil, no flow conditioner
Flowrate
Mete
r Facto
r
2 000 20 000 200 000 2 000 0000,990
0,991
0,992
0,993
0,994
0,995
0,996
0,997
0,998
0,999
1,000
1,001
1,002
1,003
1,004
1,005
1,006
1,007
1,008
1,009
1,010
DFX-MM 08'' : baselines v/s Reynolds NumberFlowstraightener 7 D long, ball prover volume 10m3
JET FUEL 5,0 cst 17 °C Water 6%JET FUEL 4,5 cst 24 °CJET FUEL 4,5 cst 24 °C Ball valve 40% closedGASOIL 8,4 cst 18 °CGASOIL 8,4 cst 18 °C Ball valve 40% closedOIL 15,5 cst 22 °COIL 62,0 cst 16 °CSam e oil , no f low condit ioner
Reynolds Number
Mete
r Facto
r
02/1
0/20
09 P
age4
L002
G D
FX-M
M lea
flet
DFX-MM Software
DFX-MM interfacing is easy and cost effective thanks to its Web server and Ethernet link,making skid commissioning, meter health check and auditing operations straightforward.
DFX-MMCalibration curves
DFX-MM is provable with standard ball provers thanks to repeatability improved by its unequal spatial coverage and ultra-fast scanning rate.
DFX-MM accurately measures viscous flows and therefore is ideal when pressure drop is the concern.
50 100 150 200 250 300
0,998
0,999
1,000
1,001
1,002
DFXMM 06 - HEAVY OIL
300 cent is t ockes mineral oil, 6'' PD mast er met er
FLOWRATE M3/H
ME
TE
R F
AC
TO
R
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
-0,06%
-0,04%
-0,02%
0,00%
0,02%
0,04%
0,06%
DFXMM 08 - REPEATABILITY testDiesel oil 4.9 cs t - 600 m3/h - 10 m3 ball prover - 15 runs
RUN n°
ME
TE
R E
RR
OR
%
02/1
0/20
09 P
age5
L002
G D
FX-M
M lea
flet
Min. Max. Min. Max.
04" * 100 15 350 100 2200
150 30 800 200 5000
200 60 1400 400 8800
250 90 2200 600 13800
300 130 3200 800 20100
350 160 3800 1000 23900
400 200 5000 1300 31400
450 250 6200 1600 39000
500 350 7800 2200 49100
600 500 11000 3100 69200
650 600 13000 3800 81800
700 700 16000 4400 100600
750 900 18000 5700 113200
800 1000 20000 6300 125800
850 1100 23000 6900 144700
900 1200 26000 7500 163500
950 1300 29000 8200 182400
1000 1400 32000 8800 201300
42" 1050 1500 36000 9400 226400
Nominal flow-rangesfor standard accuracy +/-0,15%
Meter size Flow rat e (m3/h) Flow rat e (BPH)
Inch mm
06 "
08 "
10"
12"
14"
16"
18"
20"
24"
26"
28"
30"
32"
34"
36"
38"
40"
* 15 beams design
M in. Max. M in. Max.
04" * 100 30 300 200 1900
150 65 650 400 4100
200 120 1200 800 7500
250 200 2000 1300 12600
300 300 3000 1900 18900
350 320 3200 2000 20100
400 400 4000 2500 25200
450 520 5200 3300 32700
500 650 6500 4100 40900
600 1000 10000 6300 62900
650 1150 11500 7200 72300
700 1350 13500 8500 84900
750 1550 15500 9700 97500
800 1750 17500 11000 110100
850 2000 20000 12600 125800
900 2200 22000 13800 138400
950 2500 25000 15700 157200
1000 2750 27500 17300 173000
42" 1050 3000 30000 18900 188700
Nominal flow-rangesfor premium accuracy +/-0,1%
Met er siz e Flow rat e (m3/h) Flow rat e (BPH)
Inch mm
06"
08"
10 "
12"
14"
16"
18"
20 "
24"
26"
28"
30 "
32"
34"
36"
38"
40 "
# 150 # 300 # 600 #900 # 150 # 300 # 600 # 900
4'' 100 16 406 51 60 72 79 113 132 159 174
6'' 150 18 457 70 88 113 151 154 194 249 333
8'' 200 20 508 99 125 159 215 218 275 350 473
10'' 250 22 559 139 176 240 300 306 388 528 660
12'' 300 24 610 186 232 328 394 410 511 722 867
14'' 350 28 711 230 300 352 506 660 775
16'' 400 32 813 258 364 448 568 801 986
18'' 450 36 914 295 442 650 973
20'' 500 40 1016 350 504 770 1101
24'' 600 48 1220 495 721 1089 1587
26'' 650 52 1321 568 866 1250 1906
28'' 700 56 1422 646 1035 1422 2277
30'' 750 60 1524 748 1192 1646 2623
32'' 800 64 1626 862 1322 1897 2909
34'' 850 68 1727 951 1553 2093 3417
36'' 900 72 1829 1072 1742 2359 3833
38'' 950 76 1930 1194 2627
40'' 1000 80 2032 1355 2981
42'' 1050 84 2130 1423 3130
Length & Weight*
Met er size Meter length Weight (Kg) Weight (lb)
Inch mm Inch mm
Note : g iven length a re for face to face flanges
02/1
0/20
09 P
age6
L002
G D
FX-M
M lea
flet
DFX-MM Performances & datas
METROLOGY :
API MPMS ch5.8M.I.D. 2004/22/EC
:
:
Installation :
CERTIFICATIONS
:pressure : P.E.D. 97/23/EC
ASME B31.3:: E.M.C 89/336/EC: I.P. 66/67 IEC529
ENVIRONMENT :
Pressure ::
:
BODY :
: ANSI #150 #300 #600
: full bore
CONVERTER:
Pulse volume output :Communication port :
:
Compliances OIML R117-1 class 0.3
Accuracy +/- 0,15% from 0.5 to 12 m/s+/- 0,10% from 1 to 10 m/s
Repeatability provable, 0.05% 5 runs with conventional prover loops
10D upstream with recommended flow conditionner + 3D downstream
compliant with all relevant European Community standardsSafety ATEX 94/9/EC II 2 G Exd IIB T6
Metrology OIML R117-1 (PTB-1.5-4037579, Gosstandart)Environment
Ingress protection
Temperature process : -55°C to + 120°CAmbient: -55°C to + 55°C
Up to 100 barViscosity 0.1 to 600 centistockes
please consult M&T for higher viscositiesDensity 400 to 1500 kg/m3
Materials Carbon steel, Low temp carbon steel, Stainless steel, Duplex
Flanges
Internal
Power supply 110 / 220 VAC 50/60 Hz or 18 / 32 VDC, 10W, isolation 1500Vtwo static relays 350V 0.12A isolation 5000V 10/100Base-T IEEE 802.3 Ethernet link RJ45, optional Wifi 802.11 b & g, optical fiber, RS485
Protocols HTTP, HTTPs, Telnet, SNMP, Modbus TCP
Please contact M&T for specifications outside above standard ones
02/1
0/20
09 P
age7
L002
G D
FX-M
M lea
flet
DFX-MM Specifications
A B - C D - E F - G H
DFX-MM 12 - A 1 - 1 1 - 1 0
DFX-MM Ordering contacts
Section A : Product line
DFX-MM
Section B : Meter Size
04 4'' / DN100
06 6'' / DN150
08 8'' / DN200
10 10 '' / DN250
12 12'' / DN300
14 14'' / DN350
16 16'' / DN400
18 18'' / DN450
20 20'' / DN500
24 24'' / DN600
Section C : Pressure Class
A 150# ANSI R.F. Flanges
B 300# ANSI R.F. Flanges
C 600# ANSI R.F. Flanges
D Other (please contact us)
Section D : Materials of construct ion
Body Flanges Transducers
1 C.S A106 or equ. C.S A105 or equ. Peek / SS 316L
2 L.T.C.S. A333 Gr6or equ.
L.T.C.S. A350 LF2 orequ.
Peek / SS 316L
3 SS 316L or equ. SS 316L or equ. Peek / SS 316L
4 Other Other Peek / SS 316L
Section E : Installat ion condit ions
1 Standard with recommended flow straightener
2 Standard without flow straightener
3 Customized
Sect ion F : Accuracy class
1 standard +/-0.15%
2 premium +/-0.1%
Section G : Documentat ion
0 None
1 Standard
2 Customized
Section H : Special request
0 None
S Special request
DFX-MMOrdering codes
METERING & TECHNOLOGY S.A.S.- S.A.S. au capital de 37 500 € - R.C.S. 494 307 457 Chartres - TVA FR60494307457 - www.mnt-sas.com
Parc des Propylées II - 5, Allée Prométhée - 28000 CHARTRES FRANCE Tel:+33(0)965 027 803 / 237 835 446 Fax:+33(0)237 835 547 - [email protected]
METERING & TECHNOLOGY S.A.S.Address : Parc des Propylées II - 5, Allée Prométhée
28000 CHARTRES FRANCE
Tel: +33 (0) 965 027 803 / 237 835 446Fax: +33 (0) 237 835 547E.mail : [email protected] : www.mnt-sas.com
02/1
0/20
09 P
age8
L002
G D
FX-M
M lea
flet