The SEEFIRE project is co-funded by the European Commission under the FP6 IST contract no. 15817 www.seefire.org SEEFIRE DF plans & experiences from Greece Jorge-A. Sanchez-P. Greek Research & Technology Network sanchez at grnet.gr www.grnet.gr

DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

  • Upload
    ngodien

  • View
    218

  • Download
    3

Embed Size (px)

Citation preview

Page 1: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

The SEEFIRE project is co-funded by the European Commission under the FP6 IST contract no. 15817

www.seefire.org

SEEFIREDF plans & experiences from Greece

Jorge-A. Sanchez-P.Greek Research & Technology Network

sanchez at grnet.grwww.grnet.gr

Page 2: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 2

Content

GRNET – network infrastructures & Grid infrastructuresDark fibre plans & experiencesEquipment lighting dark fibres plans and experiences

Page 3: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 3

GRNET – Network infrastructure

12-PoP high speed backbone network based on 2.5Gbps leased lambdasand Gigabit routers.Interconnects academic and research institutions (more than 80 today) at up to 1Gbps and primary and secondary schools (more than 10.000) at Mbps.A total of up to 1.500.000 potential end-users. International 2x2.5Gbps (to be upgraded to 2x10Gbps – 3Q05)Used the structural funds

Page 4: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 4

GRNET – Grid infrastructure

6 clusters/sites in deployment (770 CPUs, 34 TBs storage).Involves all major research and academic institutes working on Grids-eScience all over Greece.

High Energy Physics, Bio-informatics, Meteorology, Astronomy, Computer scientists-Virtual Collaboration Environments

Providing services to the Pan-European GRID community through the EGEE Project and the SEE community through the SEE-GRID Project.Used the structural funds

Page 5: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 5

Content

GRNET – network infrastructures & Grid infrastructuresDark fibre plans & experiencesEquipment lighting dark fibres plans and experiences

Page 6: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 6

GRNET DF tenders

GRNET has published two DF tenders

15-year IRUs, issued in the beginning of 2005 (green links)20-year IRUS, issued at the end of 2005 (blue links)

Budget:15-years IRUs + maintenance : 4ME20-years IRUs + maintenance : 13,5ME

|Used the structural funds

Λάρισα

Πάτρα

Κόμβος ΕΔΕΤ

ΜΑΝΑθήνας

Σύρος

Ηράκλειο

Ιωάννινα

Χανιά

Ρέθυμνο

Θεσσαλονίκη

Υπάρχουσα διαδρομήοπτικών ινών

Ζητούμενη διαδρομήοπτικών ινών

Ξάνθη

ΣάμοςΤρίπολη

Page 7: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 7

DF RFP I details

Unprotected fiber pairs 10Gbps transmissionOne terrestrial in northern Greece (Thessaloniki-Xanthi)Two submarine lines in the Aegean Sea (Syros-Samos islands and Athens-Crete)

Single-mode fiber, preferably G.655 or G.652 c/d. 3-6 months for implementation

Existing fiber in inter-city parts of the span was a requirementFault terms

3 days for repairing terrestrial fiber in case of cuts 20 days for repairing submarine cuts

RFP followed by an RFI for transmission equipment

Page 8: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 8

DF RFP I received offers

932 km of dark fibre932 km of dark fibre

GRnetPoP1

GRnetPoP2

CarrierPoP2 90 km

CarrierPoP1140 km 70 km

G.652 fibre

GRnetPoP5

GRnetPoP6

CarrierPoP7

CarrierPoP6 164 km 174 km36 km

CarrierPoP8

8 km

G.652 fibre

GRnetPoP3

GRnetPoP4

CarrierPoP5

CarrierPoP3 115 km 100 km46 km

G.653 fibre G.652 fibre

CarrierPoP4

8 km

AttenuationAttenuation 00..32 32 dBdB//KmKm , , 00.25.25 dBdB//KmKm (submarine)(submarine)CDCD G.652 G.652 -->> 1616..5 5 psps//nmnm//kkm (m (atat 1550 1550 nmnm))

G.653 G.653 --> > 0 0 psps//nmnm//kkm (m (atat 1550 1550 nmnm))PMD PMD 00..050 050 psps//((KmKm))1/21/2

Page 9: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 9

DF RFP II details

Collocation at the edges of each span.The contractor must not place any active or passive equipment along the fiber span.Availability ≥ 99% The contractor has the obligation to replace existing fiber pair with improved technical characteristics fiber, if this becomes available.Price:

15 years IRU(euro/m)

Annual Maintenance

2-2.9 5% * IRU

20 years IRU(euro/m)

Annual Maintenance

2.5-3 3.5% * IRU

Page 10: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 10

Content

GRNET – network infrastructures & Grid infrastructuresDark fibre plans & experiencesEquipment lighting dark fibres plans and experiences

Page 11: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 11

RFI for optical equipment

Beginning of 05, issued an RFI for optical transmission and regeneration/ amplification equipment.19 manufacturers responded:

AdvaAMS-JDS UniphaseBTI PhotonicsCienaCiscoCube OpticsEntrada NetworksHitachiHuawei

Last MileMarconiMovazMRVMeritonSiemensSorrento NetworksSycamore TransmodeWavium

Page 12: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 12

RFI for optical equipment cont’d

Type-A Equipment Client-side

Gigabit Ethernet from day 1 (mandatory) STM-16 (highly desirable) STM-4 at the client side (optional)10 Gigabit Ethernet at the client side (optional)

Transmission-side:Aggregate capacity of at least 1Gbps from day 1 upgradeable to N*2,5 Gbps (mandatory) or N*10Gbps (desirable), with N>=1. Support of bidirectional use of a single fiber at the transmission side (highly desirable).

Type-B EquipmentOptical signal “expansion” (mandatory)

Optical-Electrical-Optical (OEO) - Regeneration Amplifiers (e.g. EDFA, SOA) coupled with appropriate dispersion compensation modules.

Support of bidirectional use of a single fiber (highly desirable).

Page 13: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 13

RFI for optical equipment - Responses

Loss budget for xWDM transponders ranges from 24-30dbs.By using preamplifiers and boosters a 45 db span can be implemented.Terminal equipment supports pluggable CWDM or DWDM transponders.Most manufacturers support multi-rate transponders

Client interfaces’ protocol/rate is manually configured.No frame size limit.

A great number of manufacturers support line cards muxing 2x1GbE to SDH STM-16 framing. Bidirectional use of fiber inserts attenuation and limits maximum spans length.

Page 14: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 14

Regeneration or Amplification?

Amplification

TP

TP

clientinterfaces

TP

TP

clientinterfaces

Number of new TPs for adding a new lambda: 2

EDFA

Regeneration is cost-effective when a limited number of lambdas is deployed. As the number of deployed lambdas increases amplification is by far the most cost-effective solution.

Regeneration

TP

clientinterfaces

TP

TP

clientinterfaces

Number of new TPs for adding a new lambda: 4

TP TP TP

TP TP

Page 15: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 15

RFI for optical equipment - Cost

Price for implementing a 2-span single CWDM λ link starts from 30.000 euros.Price for DWDM transponders starts from 8.000 eurosPrice for CWDM transponders starts from 4.000 eurosPrice for EDFAs range among 15.000-40.000 euros.

GigE

1 CWDM λ 1 CWDM λ

GigE

Page 16: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 16

CWDM or DWDM?

Price difference among same manufacturer’s CWDM and DWDM transponders ranges from 20 to 50%. However CWDM is not a scalable solution for backbone links; EDFAs cannot amplify more than 2 CWDM lambdas.

Page 17: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 17

RFP for optical equipment

Issued on September 05.Offers opened on the 21st of NovemberBudget 375KE.

Types of equipmentType 1: Terminal equipmentType 2: Lambda add/drop equipmentType 3:Regeneration/amplification equipment

Page 18: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 18

Minimum requirements

Type 1 Type 3 Type 3 Type 1GRNETL2/3

equipment

1 GigabitEthernet

CWDM or DWDMlambda

1 GigabitEthernet

GRNETL2/3

equipment

At least one e2e CWDM or DWDM lambda framed as 1 GbEScalability: up to 8 lambdas“Smooth” addition of new lambdas

Page 19: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 19

Other requirements

3RClient interfaces must support 1GbE through either

Transparent transponders orTransponders that mux 2x1GbE signal to an STM-16 framed lambda.

Jumbo frames support is a mustLine interfaces:

ITU-T CWDM/DWDM lambdasITU-T G.709 supportSFP MSA supportSFF 8472 support

SNMP supportSerial/telnet/ssh accessEMS and NMS (optional)Testbed implementationTraining to GRNET personnel3-years supportNext business day replacement of faulty equipment

Type 1 Type 1GRNET L2/3equipment

at leastx 1 GbE

At least 3 CWDMlambdas

distance >= 2km

at leastx 1 GbE

GRNET L2/3equipment

Page 20: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 20

Dark fibre plans (2006+)

The whole of the GRNET backbone is planned to be implemented using dark fibre pairs obtained via long-term IRUs. Dark fibre for local loops to all major academic institutions are vurrently being acquired via a structural funds project (Using the structural funds)Development of fiber rings at Greek municipalities

Fiber rings will connect public administration offices, hospitals, universities and telehouses.Used the structural funds: 54ME Municipalities will provide IRUs to companies for private use. Charging will be cost-based.Most metropolitan networks are expected to be ready by the end of 2006.GRNET will greatly benefit from Metropolitan networks

Actions for obtaining dark fibre towards the northern part of Greece, in an attempt to establish cross border fibre links with neighbouring countries, are also planned.

Page 21: DF plans & experiences from Greece - TERENA · DF plans & experiences from Greece ... Huawei Last Mile Marconi Movaz MRV Meriton ... Terminal equipment supports pluggable CWDM or

SEEFIRE workshop – Sofia, 14-15 July 2005 21