30
1 Life Technologies™ | Development of a “Global” STR Multiplex for Human Identification Analysis Jonathan Tabak Life Technologies

Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

1Life Technologies™ |

Development of a “Global” STR

Multiplex for Human Identification Analysis

Jonathan TabakLife Technologies

Page 2: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

2Life Technologies™ |

Agenda

Introduction

Multiplex Configuration Strategy

Application-Specific Development and Testing Results

− Direct amplification for single source samples

− Casework samples

Summary

Page 3: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

4Life Technologies™ |

What is GlobalFiler™?

1. D.R. Hares, Expanding the CODIS core loci in the United States, Forensic Sci. Int. Genet. 6 (2012), e52-e54.

2. D.R. Hares, Addendum to expanding the CODIS core loci in the United States, Forensic Sci. Int. Genet. 6 (2012), e135.

The GlobalFiler™ Kits are our response to the worldwide expansion of forensic locus sets, recently captured in the CODIS Core Loci Working Group’s recommendation to expand the CODIS Core Loci from 13 to 20 “required” loci and 3 “highly recommended” loci

LocusCODIS

(Current)Europe

CODIS(Proposed)

GlobalFiler™ Kit

D13S317 X X X

D7S820 X X X

D5S818 X X X

CSF1PO X X X

D1S1656 X X X

D12S391 X X X

D2S441 X X X

D10S1248 X X X

D18S51 X X X X

FGA X X X X

D21S11 X X X X

D8S1179 X X X X

VWA X X X X

D16S539 X X X X

TH01 X X X X

D3S1358 X X X X

AMEL X X X X

D2S1338 X X X X

D19S433 X X X X

DYS391 X X

TPOX X X X

D22S1045 X X X

SE33 X X X

Page 4: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

5Life Technologies™ |

MINIMUM REQUIRED LOCI

Amelogenin Identifiler® & NGM SElect™ Kits

D13S317 Identifiler® Kit

D7S820 Identifiler® Kit

D5S818 Identifiler® Kit

CSF1PO Identifiler® Kit

D1S1656 NGM SElect™ Kit

D12S391 NGM SElect™ Kit

D2S441 NGM SElect™ Kit

D10S1248 NGM SElect™ Kit

D18S51 Identifiler® & NGM SElect™ Kits

FGA Identifiler® & NGM SElect™ Kits

D21S11 Identifiler® & NGM SElect™ Kits

D8S1179 Identifiler® & NGM SElect™ Kits

VWA Identifiler® & NGM SElect™ Kits

D16S539 Identifiler® & NGM SElect™ Kits

TH01 Identifiler® & NGM SElect™ Kits

D3S1358 Identifiler® & NGM SElect™ Kits

AMEL Identifiler® & NGM SElect™ Kits

D2S1338 Identifiler® & NGM SElect™ Kits

D19S433 Identifiler® & NGM SElect™ Kits

DYS391 Yfiler® Kit

HIGHLY RECOMMENDED LOCI

(1) TPOX Identifiler® Kit

(2) D22S1045 NGM SElect™ Kit

(3) SE33 NGM SElect™ Kit

• Original recommendations (April 2011) included 21 loci “required” and 4 “highly recommended” for inclusion by manufacturers1

• Revised recommendations (January 2012) removed the Penta E and Penta D loci2

• The revised list includes all markers commonly used in U.S. and Europe, already found in the NGM SElect™ & Identifiler® Series Kits

• GlobalFiler™ Kits include all required and recommended loci within a single multiplex

1. D.R. Hares, Expanding the CODIS core loci in the United States, Forensic Sci. Int. Genet. (2011), doi:10.1016/j.fsigen.2011.04.01

2. D.R. Hares, Addendum to expanding the CODIS core loci in the United States, Forensic Sci. Int. Genet. (2012), doi:10.1016/j.fsigen.2012.01.003

CODIS Loci Recommendations

Page 5: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

6Life Technologies™ |

Customer Feedback

“With so many loci, isn’t there a risk of losing

sensitivity and having more drop out?”

“Our lab is dealing with more low level trace and touch type samples, and analysis

can be a nightmare, especially with mixtures. With even more loci, I think that

difficulty could increase exponentially.”

“We are already facing big backlogs and budget shortfalls. Having to purchase

and implement new instrument platforms is an enormous additional

hurdle.”

*Source: 2011 HID Future Trends in Forensic DNA Analysis Technology Seminar Series, Technical Lead Mtgs.

Page 6: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

7Life Technologies™ |

Multiplex Configuration Strategy

Page 7: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

8Life Technologies™ |

5-Dye Configuration Containing All Required and Highly Recommended Loci

12

3

4

Multiple loci > 400 bp poor performance for degraded DNA compromised sizing and resolution

12

3

45

6

7 8

Fewer Mini-STRs poor performance for

degraded DNA

Primer Redesigns less concordant

Page 8: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

9Life Technologies™ |

The GlobalFiler™ Kits: 6-Dye Configuration

12

3

45 6

78

9 10

GlobalFiler™ Kit10 Mini-STRs

PI* = 9.2 x 10-12

MiniFiler ™ Kit8 Mini-STRs

PI* = 1.05 x 10-10

11 12

13 14

15

16 17

18

18 Mini-STRs Combination

PI*= 5.73 x 10-21

97% of alleles inallelic ladder <400bp

Only 2 loci require primer redesign

* Preliminary calculations based on a US Caucasian Database

Page 9: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

10Life Technologies™ |

The GlobalFiler™ Kits: Configuration

p q

Amelogenin DYS391

DYS391

AmelAll gender

markers located in the same dye

channel for ease of interpretation

Y indel

/ Y indel

Deletion Insertion

Page 10: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

12Life Technologies™ |

• Indels are short length polymorphisms, consisting of the presence (INsertion) or absence (DELetion) of a short sequence (1-50 nucleotides)

• In the GlobalFiler™ Kits, an Indel marker on the Y chromosome was incorporated into the multiplex

Deletion Insertion

What is an Indel?

Page 11: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

13Life Technologies™ |

Gender identification redundancy helps remove the need for laboratories to maintain a second gender confirmation test protocol

In addition, the Y-indel position (<90 bp) in the GlobalFiler™ Kit helps improve data recovery in degraded samples

Improved Accuracy of Gender Determination

Page 12: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

14Life Technologies™ |

The GlobalFiler™ Kits: Allelic Ladder

New virtual bins added to

improve genotyping efficiency

343 alleles246 virtual bins589 total alleles

31 alleles added to 9

GlobalFiler™ Kit marker ladders

Page 13: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

15Life Technologies™ |

The GlobalFiler™ Kits Allelic Ladder Improvements

D19S433

GlobalFiler™ Kit range: 6-19.2

NGM SElect™ Kit range: 9-17.2

GlobalFiler™ Kit range: 11-28

Identifiler® Kit range: 15-28

D2S1338

Page 14: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

16Life Technologies™ |

• Literature reports indicate instances of false homozygosity in the Identifiler®/NGM SElect™ Kits as a result of primer site SNP mutations

• Eight new SNP-specific primers have been included in the GlobalFiler™ Kits to minimize the occurrence of null alleles in future data sets

− A series of SNP-specific primers already exist in the Identifiler®/NGM SElect™ Kits to account for other primer site mutations

GlobalFiler™ Kit Loci with New SNP-Specific Primers

D3S1358

vWA

D18S51

D19S433

TH01

FGA

D5S818

SE33

More Genotyping Accuracy: Minimizing False Homozygosity

Page 15: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

17Life Technologies™ |

Maximizing Discrimination

Kit

D8

S1

17

9

D2

1S

11

D7

S8

20

CS

F1

PO

D3

S1

35

8

TH

01

D1

3S

31

7

D1

6S

53

9

D2

S1

33

8

D1

9S

43

3

vWA

TP

OX

D1

8S

51

D5

S8

18

FG

A

D1

0S

12

48

D2

2S

10

45

D2

S4

41

D1

S1

65

6

D1

2S

39

1

SE

33 PI

Identifiler® Kit X X X X X X X X X X X X X X X 5.01 x 10-18

NGM SElect™ Kit X X X X X X X X X X X X X X X X 2.35 x 10-21

GlobalFiler™ Kit X X X X X X X X X X X X X X X X X X X X X *7.12 x 10-26

GlobalFiler™ Mini’s X X X X X X X X X X *9.20 x 10-12

* Preliminary calculations based on a US Caucasian Database

The GlobalFiler™ Kits will:− Deliver a new level of discrimination

− Reduce the risk of adventitious matches

− Facilitate international DNA profile comparisons

Page 16: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

18Life Technologies™ |

Source - www.prb.org/

The GlobalFiler™ Kits offer a power of discrimination ~1014 times greater than the total population that has ever lived on Earth!

GlobalFiler™ Kit PI = 7.12 x 10-26 = 1 in 1.4 x 1025

Total Historical Human Population = 1.1 x 1011

An Unprecedented Power of Discrimination

Page 17: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

19Life Technologies™ |

3130 Series Genetic Analyzers

GeneMapper® ID-X Software v1.4

GeneAmp® 9700 Thermal Cycler

with Silver or Gold-Plated

Silver 96-Well Block

Veriti® Thermal Cycler

3500 Series Genetic Analyzers

3730 Genetic Analyzer (GlobalFiler™ Express Kit

only)The GlobalFiler™ Kits utilize the DS36 (J6) Matrix

Standard Set

GlobalFiler™ Kits: Instrument Compatibility

Page 18: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

20Life Technologies™ |

Instrument Compatibility

3500xL 3130xl

Page 19: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

21Life Technologies™ |

Instrument Compatibility

3500xL 3730

Page 20: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

22Life Technologies™ |

Improved Reagent TraceabilityPackaging Improvements for the GlobalFiler Kits

New “Peel and Stick” kit labels can be removed from kit sleeves and placed on component boxes or recorded in laboratory logbooks

Improves ability to link kit components with kit lot numbers

Page 21: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

23Life Technologies™ |

Application Specific Development & Testing

Page 22: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

24Life Technologies™ |

Kit Development Strategy

GlobalFiler™

PCR Amplification KitGlobalFiler ™ Express PCR Amplification Kit

The GlobalFiler™ Kits

A high performance, 6-dyechemistry for casework

samples

An ultra-high throughput, 6-dye chemistry for single

source samples

Page 23: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

25Life Technologies™ |

The Diverse Demands of Forensic Testing

− Predictable

− Standardized collection

− High yield, high quality DNA

− Single source

− Fresh

− Unpredictable

− Highly variable substrates

− Low yield, low quality DNA

− Mixed source

− Aged

The Samples

− Medium - high throughput

− High 1st pass success rate

− Minimal sample transfer and processing steps

− Eliminate rate limiting steps

− Automated processing

− Low - medium throughput

− Maximum results from compromised samples

− High sensitivity

− Maximum specificity

− Simplified interpretation

Key Workflow Requirements

Databasing Casework

Page 24: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

26Life Technologies™ |

GlobalFiler™ Express Kit Workflows

Page 25: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

27Life Technologies™ |

Optimizing Reaction Time for the GlobalFiler™

Express Kit

Protocols developed on Veriti® thermal cyclers using 100% ramp speed

Performance verified on the 9700 thermal cyclers using MAX mode

Identifiler® Direct Kit

NGM SElect™

Express KitGlobalFiler™

Express Kit

Total Time 2 hr 35 min 45 min 39 - 40 min

PCR Conditions95°C/ 1 min94°C/ 3 sec60°C/ 30 sec60°C/ 8 min

25-27 x

Page 26: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

28Life Technologies™ |

GlobalFiler™ Kit: Casework Design Considerations

Casework Kit Performance Requirements:

High sensitivity for trace/low level DNA samples

Good intracolor balance for mixture samples

Sufficient tolerance to PCR inhibitors

Maintain high species specificity

Efficient thermal cycling conditions

Page 27: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

29Life Technologies™ |

Optimization of GlobalFiler™ Kit Reaction Conditions

Reagent Volumes

3.3X Master Mix 7.5 µL10X Primer Set 2.5 µLSample Input ≤15.0 µL

25.0 µL

Greater flexibility of sample input volume to facilitate analysis of low level samples

Identifiler® Plus & NGM SElect™ Kits

GlobalFiler™ Kit

Total Time 2 hr 25 min 1 hr 20 min

PCR Conditions

95°C/ 1 min94°C/ 20 sec59°C/ 90 sec60°C/ 10 min

29 x

Optimized thermal cycling conditions shorten amplification conditions by > 1 hr

Page 28: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

30Life Technologies™ |

Development of a Next Generation Global Multiplex Go Faster!

− Up to 5x faster amplification time than previous generation kits

> GlobalFiler™ Express Kit: ~40 minutes; GlobalFiler™ Kit: ~80 minutes

> Enables sample to answer in <2 hours

Go Further!

− 24 loci, including 10 mini-STRs, increasing discrimination power by up to 9 orders of magnitude

− Enhanced buffer system and sensitivity for even better performance on inhibited and low-level samples

Go Global!

− The only kit containing all markers recommended for inclusion by the CODIS Core Loci Working Group, including all markers commonly used in Europe

− Maximizes global database compatibility

Page 29: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

31Life Technologies™ |

Acknowledgements External Test Sites

− 66 worldwide and growing!

R&D

Julio Mulero, Lori Hennessy, Siddhita Gopinath, Wilma Norona, Matthew Ludeman, Robert Lagace, Chien-Wei Chang, Chang Zhong, Nigel Beard

Tech Transfer

Larry Wang, Anthony Matthews, Vanessa Chan, Yenyoung Lei

Software

Allan Minn, Gloria Lam, Sharada Vijaychander, Tony Hatch, Makesh Kumar, Ravi Gupta, Doug Greig, Babu Yama

Product Management

Karen Cormier, Larry Joe, Jacki Benfield

Forensic Science ApplicationsJennifer Schroeder, Lisa Calandro, Jeff Sailus, Nicola Oldroyd

Quality AssuranceLiwei Qi, Yurah Yen

MarketingAriana Wheaton, Jonathan Tabak, Shereen Darwish, Lisa Schade

Oligo DevelopmentSarah Ruhe, Kathy Wang, Hong Ji

UK ManufacturingCatherine Duke

Project ManagementWendy Coffey, Linda Kauffman

Page 30: Development of a “Global” STR Multiplex for Human Identification Analysisafdaa.org/.../uploads/2013/01/GlobalFiler-AFDAA-2-7-13-.pdf · 2013. 2. 8. · Development of a “Global”

32Life Technologies™ |

Thank You

© 2012 Life Technologies Corporation. All rights reserved. The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners.

Refer to product page on the Life Technologies website for Limited Use License.

The content provided herein may relate to products that have not been officially released and is subject to change without notice.

FOR FORENSIC AND PATERNITY USE ONLY

http://www.slideshare.net/Lifetech_HID

http://www.lifetechnologies.com/globalfiler