Development & Building Control
Welcome to e-Learning
for
Submission
of
Development Control Plan
Next
Overview Of Submission Sequence For Road Proposals
Development & Building Control
Development Control Plans
1
Street Plans
2
Certificate of Statutory Completion3
Next Previous
Development Control
(DC)
Planning stage where LTA will evaluate if the proposal is viable and can meet the expectations of LTA in road and traffic operations & safety.
This is the stage which has a significant impact on the overall layout design of the development.Generally, architect will submit the DC plan to LTAfor clearance.
Once the proposal is deemed acceptable to LTA, a DC clearance will be issued.
Development Control Plans
Next Previous
Development & Building Control
Suitability of Access Suitability of Access PointsPoints
Adequacy of New Adequacy of New Road ProposedRoad Proposed
Extent of Frontage Extent of Frontage ImprovementImprovement
Adequacy of Commuter FacilitiesAdequacy of Commuter Facilities
The Need For Improvement to The Need For Improvement to Current Traffic SchemeCurrent Traffic Scheme
Whether Traffic Impact Whether Traffic Impact Assessment (TIA) is requiredAssessment (TIA) is required
Development Site
Key Evaluation Areas
Next Previous
Development & Building Control
How to Prepare a DC Submission
for
LANDED HOUSING
Next Previous
Development & Building Control
Topics For Landed Housing(click on one of the topics
below)
Next Previous
Development & Building Control
ommon errors
lan presentation
ccess point
evelopment
frontageIs your development
affected by road reserve?
es o
Plan Presentation
Project title
Name & address of owner
• Provide title block with project caption, name, address & contact number of owner and architect• Show location plan• Show site plan
SITE
Location PlanScale 1:500
road name
Site PlanScale 1:100
Next
(Plan Presentation page 1 of 4) Development
FrontageAccessPoint
CommonErrors
Plan Presentation
Project title
Name & address of owner
1st Storey PlanScale 1:100
road name
2nd Storey PlanScale 1:100
Roof PlanScale 1:100
• Show 1st Storey Plan• Show all floor plans Next Previous
(Plan Presentation page 2 of 4) Development
FrontageAccessPoint
CommonErrors
Plan Presentation
• Show cross section & elevations
Project title
Name & address of owner
Rear ElevationScale 1:100
Front ElevationScale 1:100
Scale 1:100
Side Elevation
Section X-XScale 1:100
Next Previous
(Plan Presentation page 3 of 4) Development
FrontageAccessPoint
CommonErrors
Plan Presentation
Project title
Name & address of owner
Topographical Survey PlanScale 1:100
• Submit
topographical
survey plan
Next Previous
(Plan Presentation page 4 of 4) Development
FrontageAccessPoint
CommonErrors
Access Point
Guidelines:
• 50m away from road junctions / bends
• Not to be located directly opposite one another• Paired access
• Access to be 6m apart, otherwise to be paired
50m 6m
• If site is near junction, the access to be located furthest away from junctions
Site
Site
Next
(Access Point page 1 of 1) Development
FrontageCommon
ErrorsPlan
Presentation
Development affected by road reserve
Development Frontage
Site
boundary line
Road Reserve Line
Next Previous
(Development Frontage page 1 of 5) Common
ErrorsPlan
Presentation
AccessPoint
Road Reserve Line
Development Frontage
Site
boundary line
Next Previous
(Development Frontage page 1 of 4)
Development not affected by road reserve
CommonErrors
PlanPresentation
AccessPoint
Development Frontage
Not sure if your development is affected by road reserve?
Previous
Purchase Road Line Plan from http://www.inlis.gov.sg/RLP
(Development Frontage page 1 of 1) Common
ErrorsPlan
Presentation
AccessPoint
Development Frontage (With Road Widening Plot)
• Show development boundary line• Show road reserve line in red
• Show existing kerb lines• Show existing turf area
• Show existing footpath
• Show road widening plot number• Show legend for road widening plot
Road Reserve Line
Turf
Footpath
Plot 1
Plot 2
Landed house development
Road widening plot to be vested to State
2
1
Boundary Line
Next Previous
(Development Frontage page 2 of 5)
CommonErrors
PlanPresentation
AccessPoint
• Show existing open/covered drains
• Show existing lamp posts, OG box, traffic signs, manholes
• Show existing drop inlet chambers
• Show existing traffic markings, road hump, zebra crossing
• Indicate existing road levels, proposed culvert & internal platform levels
Road Reserve Line
Turf
Footpath
2
1
Existing covered drain
++
+
+ +++
+
+
Boundary Line
Next Previous
(Development Frontage page 3 of 5)
Development Frontage (With Road Widening Plot)
CommonErrors
PlanPresentation
AccessPoint
• Show road features to be deleted in dotted yellow lines• Show proposed road features in magenta• Proposed covered drain to set back and abut road reserve line
+
++
+
+ ++
+
+
Road Reserve Line
Turf
Width of access
Footpath
2
1
R R
• Indicate width of proposed access
(click here for LTA’s requirements)
• Indicate proposed turning kerb radius(click here for LTA’s requirements)
Boundary Line
Next Previous
(Development Frontage page 4 of 5)
Development Frontage (With Road Widening Plot)
CommonErrors
PlanPresentation
AccessPoint
• Proposed top level of culvert to be higher than road level• Show location of meter compartment• Show proposed relocation of lamp post affected by proposal
• Show position of side gate
• Show proposed drop inlet chamber at tangent points of the turning radius
+
++
+
+ ++
+
+
Road Reserve Line
Turf
Width of access
Footpath
2
1
Meter
Gradient
• Show gradient of proposed entrance approach
(click here for LTA’s requirements)
Boundary Line
Next Previous
(Development Frontage page 5 of 5)
Development Frontage (With Road Widening Plot)
CommonErrors
PlanPresentation
AccessPoint
• Show development boundary line• Show road reserve line in red• Show existing kerb lines• Show existing turf area • Show existing footpath & adjacent building• Show existing open/covered drains
+
++
+
+
+
+
+
+
+
Turf
Footpath
Adjacent Building
Existing footpath
Boundary Line
Road Reserve Line
Next Previous
(Development Frontage page 2 of 4)
Development Frontage (Without Road Widening Plot)
CommonErrors
PlanPresentation
AccessPoint
• Show existing lamp post, OG box, traffic sign, manhole & meter compartment
• Show existing drop inlet chambers
• Show existing traffic markings, road hump, zebra crossing
• Indicate existing road levels, proposed culvert & internal platform levels
• Annotate on plan whether the existing culvert is to be retained (if there are no proposed works to be carried out)
+Turf
Footpath
Existing culvert
to be retained?
Boundary Line
Road Reserve Line
Next Previous
(Development Frontage page 3 of 4)
Development Frontage (Without Road Widening Plot)
CommonErrors
PlanPresentation
AccessPoint
++
+
+
+
+
+
+
+
• Show road features to be deleted in dotted yellow lines• Show proposed road features in magenta
• Proposed top level of culvert to be higher than existing road level
+
++
+
+
+
+
+
+
+
Turf
Width of access
Footpath
Adjacent Building
Adjacent footpath
RGradient
• Indicate width of proposed access
(click here for LTA’s requirements)
• Indicate proposed turning kerb radius(click here for LTA’s requirements)
• Indicate gradient of entrance approach(click here for LTA’s requirements)
Boundary Line
Road Reserve Line
Next Previous
(Development Frontage page 4 of 4)
Development Frontage (Without Road Widening Plot)
CommonErrors
PlanPresentation
AccessPoint
Common Errors
• No annotation for existing road features to be retained/deleted.• Road features not shown according to colour code,
eg, yellow for deletion.
Road Reserve Line
existing drain to be retained?
existing culvert to be retained?
Boundary Line
Next
(Common Errors page 1 of 11) Plan
Presentation
AccessPoint
DevelopmentFrontage
Previous
Common Errors
• Legend for road widening plot not provided
• Road widening plot number not indicated
Road Reserve Line
2
1
Plot 1
Plot 2
Landed house development
Road widening plot to be vested to State
Boundary Line
Next Previous
(Common Errors page 2 of 11) Plan
Presentation
AccessPoint
DevelopmentFrontage
Common Errors
• Proposed drain not abutting road reserve line (affected by road reserve)
Road Reserve Line
Turf
Covered drain
Boundary Line
Next Previous
(Common Errors page 3 of 11) Plan
Presentation
AccessPoint
DevelopmentFrontage
Common Errors
• Width of proposed access not indicated• Proposed turning kerb radius not indicated
Road Reserve Line
Existing Turf
Width of access
Existing drain
R R
Boundary Line
Next Previous
(Common Errors page 4 of 11) Plan
Presentation
AccessPoint
DevelopmentFrontage
Common Errors
• Proposed covered drain cum footpath not connected to existing footpath.
Boundary Line
Next Previous
(Common Errors page 5 of 11) Plan
Presentation
AccessPoint
DevelopmentFrontage
Proposed Turf
Adjacent Building
Road Reserve Line
Adjacent Building
Proposed Footpath
Existing footpath
Existing open drain
Existing footpath
Existing open drain
Existing footpath
Existing open drain
Existing footpath
Existing open drain
Type B railingType B railing
Common Errors
• Proposed drop inlet chamber not at tangent point of proposed access
Correct position for proposed drop inlet
chamber
Tangent point
Next Previous
(Common Errors page 6 of 11) Plan
Presentation
AccessPoint
DevelopmentFrontage
Common Errors
• Type ‘B’ aluminium alloy railing not provided next to existing open drain.
Next Previous
(Common Errors page 7 of 11) Plan
Presentation
AccessPoint
DevelopmentFrontage
Common Errors
• Turning kerbs not inline with gate post
• Parapet walls not provided next to existing open drain
Next Previous
(Common Errors page 8 of 11) Plan
Presentation
AccessPoint
DevelopmentFrontage
• Parapet walls not inline with gate post
Common Errors
• Wrong location of meter compartment
METER
Turf
Footpath
Adjacent Building
Adjacent footpath
Road Reserve Line
Boundary Line
Meter compartment in the middle of access
METER
Next Previous
(Common Errors page 9 of 11) Plan
Presentation
AccessPoint
DevelopmentFrontage
• Width of existing access extended without designing for vehicular load.
Common Errors
Existing turf
Existing footpath
Adjacent Building
Road Reserve Line
Adjacent Building
Boundary Line
Width of existing culvert
Extended culvert shall be designed to take vehicular
load
Next Previous
(Common Errors page 10 of 11) Plan
Presentation
AccessPoint
DevelopmentFrontage
Common Errors
• Platform level of the development, top of entrance culvert and road edge levels not indicated
• Existing levels not shown
Turf
Footpath
Adjacent Building
Adjacent footpath
Road Reserve Line
Boundary Line
METER
+
++
+
+
+
+
+
+
+
Next Previous
(Common Errors page 11 of 11) Plan
Presentation
AccessPoint
DevelopmentFrontage
Previous
Development & Building Control
If you have any enquires or feedback, please email us
Back toTopics