Outline

• DAQ Integration– M-i-M TLU Interface testing– Timepix Producer Status

• TestBeam Measurement plans

Page 3: DESY test  beam  (DAQ  integration ,  measurement  plans,  analysis )

M-i-M TLU• Man-in-the-Middle TLU Reader is a interface to the

trigger logic unit used by the EUDET Telescope– Handle the handshake on each trigger with the

telescope system , transmit Event Number and synchronize with Timepix Producer via standard ethernet connection

– Handle the FITPix readout trigering and BUSY– Provide full digital control of Timepix Trigerring

• Control through ethernet using a simple dependence free, open Library

• Compatible with mostly any PMOD equipped FPGA Developpement board – Reusable for CLICPix readout, Timepix3 readout– Low cost (~300 CHF)

• Possibility for other Use – TDC (see next slides)– Stand-Alone trigger interface to fitpix – Synchronisation studies (proposed by DESY) FPGA Board

LVDS Signal for TLU I/O

LEMO, TTL signal for spying TLU Signal and triggering TP

Page 4: DESY test  beam  (DAQ  integration ,  measurement  plans,  analysis )

M-I-M TLU

TLU Timepix + FITPix

Microblaze (C code) PHY

Communication to PC

TLU Reader, TDC, etc

Trigger,Reset

Trigger Clock ,BUSY

Trigger

Busy

MIMTLU

Page 5: DESY test  beam  (DAQ  integration ,  measurement  plans,  analysis )

MIMTLU to increase track rate (Method 1)

• MIMOSA26 only sensitive for 220 us, but is essentially dead time free• Timepix can readout out for arbitrary time, but long dead time (20-30

ms)

MIMTLU can to scale the trigger rate sent to Timepix to keep shutter open for longer periods ~O(ms). • The producer can then send data for many TLU trigger in one event, every

X event.• Telescope still send data every event• Chunk of X telescope event are merged offline to match Timepix events• Advantage -> Increase trackrate, disadvantage -> We loose online

monitoring Backup solution to increase trigger rate

Page 6: DESY test  beam  (DAQ  integration ,  measurement  plans,  analysis )

Modification to telescope to increase track rate (Method 2)

• Mimosa26 actual readout actually read 100s of frame per trigger, throw most of them away and keep only two

• I am looking into modifying the MIMOSA26 Labview Readout to change the number of frame kept per readout– Experts say it should be possible.– To be tested in the next TB period

Preferred to increase trigger rate (until arrival of new TLU)

Page 7: DESY test  beam  (DAQ  integration ,  measurement  plans,  analysis )

MIMTLU as TDC

• MIMTLU can handle trigger up to 3.2kHz

• Internal clock in FPGA MIMTLU running at 10 MHz– MIMTLU can be used to

provide coarse time stamping (~500ns over 10s) of trigger within Timepix Shutter

– A CERN Open-Hardware TDC compatible with Spartan6 FPGA claim accuracy down to ~50ps!!

2.5kHz High-Precision Pulser

Absolute Resolution (over 2ms)

Pulse-to-pulse timing (over 2ms)

Page 8: DESY test  beam  (DAQ  integration ,  measurement  plans,  analysis )

Measurement plan for June 20131. Alignement Run, Telescope Only (1M Trigger, 1-2h)

2. Alignement Run, Telescope plus Timepix at 0 degree, TOT Mode (3h)

3. TOA Run with Various Shutter length/Clock (~ 1M Trigger, 0.5 day)

4. Optimization of Telescope plane distance (0.5 Day )

5. High Track rate run, method 1 & 2 (1 day)

6. MIMTLU TDC Run/ CLICPix Readout Synchronization tests (0.5,1 day)

7. Power Pulsing Run (If DSG available) ~(1M trigger, 0.5 day)

8. Arrhus Specific measurements (1-2 days)

Page 9: DESY test  beam  (DAQ  integration ,  measurement  plans,  analysis )

Lab issues• There has been issue with material

disapearing from the Vertex lab • Euro/swiss adapters• Lemo, scalpels, soldering equipement• USB cables • Soldering Iron was broken and not

fixed • Etc …

• Would it make sense to ask for a wall to be built to control access ? It would also define better the protected zone (RP)

• With CLICPix/Timepix3 developpement coming, it would be useful to have a second setup table for precision measurement (for example with scintillator fingers from DT, IR Lasers)• Melles griot has affordable lab table

with BreadBoard for < 4500CHF