Upload
wermerm
View
66
Download
6
Embed Size (px)
Citation preview
Answers for infrastructure.
1
2
4
7
3
56
8
11
12
9
10
13
1
2
2
3
4
5
1
2
3
4
56
7
8
9
10
Desigo Fire Safety – control panels for all of your needs
Desigo Fire Safety control panels – design and possibilities
Management Station Desigo CC
Peripheral device
BA
Cn
et
TCP/
IP/L
AN
Remote access with Desigo Fire Safety View
Fire control panel FC2025
Fire control panel FC2025
Fire terminal FT2050
Fire terminal FT2050
Fire control panel
FC2025
Fire control panel
FC2005-U2
Order no.: S54400-A9-A1
Fire control panel FC2050
Fire control panel FC2050
ASAtechnology detector
ASAtechnology detector
Notification appliance
Notification appliance
Periphery board FCI2016-U1 – Supports 252 devices – For FC2025 Order no.: S54400-A55-A1
Periphery board FCI2017-U1 – Supports 504 devices – For FC2050 Order no.: S54400-A56-A1
Option module (LED) FCM2023-U2 – Optionally available Order no.: S54400-C45-A1
Option module (blank) FCM2022-U2 – Optionally available Order no.: S54400-C44-A1
SAFEDLINK FN2001-U1– Network module Order no.: S54400-A60-A1
Remote display FT2014-U2– Black Order no.: S54400-F67-A1
Remote display FT2014-R2 – Red Order no.: S54400-B75-A1
Remote terminal FT2015-U2 – Incl. key switch, blackOrder no.: S54400-F68-A1
Remote terminal FT2015-R2 – Incl. key switch, redOrder no.: S54400-B15-A1
Battery bracket FHA2032-U1 – Secures batteries to meet
seismic requirements Order no.: S54400-B43-A1
RS485 class A module FCA2016-A1 – For serial RS485 circuit Order no.: S54400-A39-A1
Leased line/city tie module FCI2020-U1 – Can be configured with
the ‘Leased line’ or ‘City tie’ functions
Order no.: S54400-A57-A1
Remote peripheral module FCA2018-U1 – Interface to remote printers Order no.: S54400-A65-A1
License key FCA2012-U1 – Activates the Desigo Fire Safety
View functionOrder no.: S54400-P102-A1
NAC expansion FCI2011-U1 – Adds notification appliance
circuitsOrder no.: S54400-A54-A1
Releasing module XCI2001-U1 – Releasing for pre-action/deluge
sprinklerOrder no.: S54400-A69-A1
Fire terminal board FTI2001-A1- For FT2050 fire terminal Order no.: S54400-A58-A1
Expansion and networking options FC2025/FC2050
Power supply (170 W) FP2011-U1– Incl. connection cable Order no.: 500-450222
Power supply (300 W) FP2012-U1 – Incl. connection cable Order no.: S54400-Z60-A1
Power supply (170 W) FP2011-U1– Incl. connection cable Order no.: 500-450222
Power supply FC2025/FC2050
Power supply FC2005
Back box FHB2001-U1– 1 HU, black Order no.: S54400-B47-A1
Back box FHB2001-R1– 1 HU, red Order no.: S54400-B47-A2
Back box FHB2002-U1– 2 HU, black Order no.: S54400-B48-A1
Back box FHB2002-R1– 2 HU, red Oder no.: S54400-B48-A2
Outer door FHD2001-U2– 1 HU, black Order no.: S54400-B49-A1
Outer door FHD2001-R2– 1 HU, red Order no.: S54400-B49-A2
Outer door FHD2002-U2– 2 HU, black – 1 window Order no.: S54400-B50-A1
Outer door FHD2002-R2– 2 HU, red – 1 window Order no.: S54400-B50-A2
Outer door FHD2003-U2– 2 HU, black – 2 windows Order no.: S54400-B51-A1
Outer door FHD2003-R2– 2 HU, red – 2 windows Order no.: S54400-B51-A2
Inner door FHD2004-U1– Black Order no.: S54400-B52-A1
Trim kit FHA2035-U1 and FHA2035-R1 – 1HU, black and red Order no.: S54400-B42-A1 (black) Order no.: S54400-B44-A2 (red)
Trim kit FHA2036-U1 and FHA2036-R1 Order no.: S54400-B41-A1 (black)Order no.: S54400-B42-A2 (red)
Housings FC2025/FC2050
System operating units FC2025/FC2050
System operating units FC2005
Expansion options FC2005Operating unit FCM2018-U2Order no.: S54400-C40-A1
Operating unit FCM2019-U2– With LED Order no.: S54400-C41-A1
Main board and operator unit FCM901-U2 – Interface options for loops,
NACs, relays, aux. power, communication bus, city tie/leased line module
– System LCD display, LEDs, control buttons
Order no.: S54433-B100-A1
Leased line/city tie module FCI2020-U1 – Same as FC2025/FC2050 Order no.: S54400-A57-A1
Remote display FSD901-U2 – Black Order no.: S54433-C102-A4
Remote terminal FSD901-R2 – Red Order no.: S54433-C102-A3
Battery bracket FHA901-U1 – Secures batteries to meet
seismic requirementsOrder no.: S54433-B107-A1
Housings FC2005
Housing FH901-U2 – Black Order no.: S54433-B103-A1
Housing FH901-R2– Red Order no.: S54433-B103-A2
Trim kit FHA902-U1 – blackOrder no.: S54433-B103-A3
Trim kit FHA902-R1– redOrder no.: S54433-B103-A4
1 Outer door
– FHD2002-U2 2 HU, 1 window, black
– FHD2002-R2 2 HU, 1 window, red
– FHD2003-U2 2 HU, 2 windows, black
– FHD2003-R2 2 HU, 2 windows, red
4 Operator interface
– FCM2018-U2 standard operating unit
– FCM2019-U2 operating unit with LEDs
6 SAFEDLINK
– FN2001-U1
7 Periphery board
– FCI2016-U1 252 pt
– FCI2017-U1 504 pt
8 Back box
– FHB2002-U1 2 HU, black
– FHB2002-R1 2 HU, red
2 Clear window
– FHD2006-U1
3 Inner door
– FHD2004-U1 with opening
11 Power supply
– FP2011-U1 170 W, 24 VDC
– FP2012-U1 300 W, 24 VDC
12 Battery bracket
– FHA2032-U1
9 DACT
– FCA2015-A1
10 Fiber module (SM and MM)
– FN2006-U1 single-mode fiber
– FN2007-U1 multi-mode fiber
13 Inner door
– FHD2005-U1 solid
5 RS485
– FCA2016-A1
1 Main board and operator unit
– FCM901-U2
4 Operator interface
– FCM2018-U2 standard operating unit
– FCM2019-U2 operating unit with LEDs
2 Clear window
– FHD2006-U1
1 Outer door
– FHD2001-U2 1 HU, black
– FHD2001-R2 1 HU, red
3 Inner door
– FHD2004-U1 with opening
6 SafeDLink module
– FN2001-U1
5 RS485
– FCA2016-A1
2 Housing
– With back box, door, window
– FH901-U2 black
– FH901-R2 red
8 Back box
– FHB2001-U1 1 HU, black
– FHB2001-R1 1 HU, red
7 Fire terminal board
– FTI2001-A1
5 City tie
– FCI2020-U1
10 Fiber module (SM and MM)
– FN2006-U1 single-mode fiber
– FN2007-U1 multi-mode fiber
4 Battery bracket
– FHA901-U1
3 Power supply
– FP2011-U1 170 W, 24 VDC
9 DACT
– FCA2015-U1
DesigoTM Fire Safety Planning Tool
FC2025/FC2050 networkable control panels
FC2005 stand-alone control panel
FT2050 fire terminal
Remote display FT2014-U2
Order no.: S54400-F67-A1
Remote terminal FT2015-U2
Order no.: S54400-F68-A1
Remote terminal FSD901-U2
Order no.: S54433-C102-A4
Customer network
NAC NAC
RS4
85
FCnet/SAFEDLINK
FDnet FDnet
RS4
85
growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. “We are the preferred partner for energy-efficient, safe, and secure buildings and infrastructure.”
Answers for infrastructure.Our world is undergoing changes that force us to think in new ways: demographic change, urbanization, global warming, and resource shortages. Maximum efficiency has top priority – and not only where energy is concerned. In addition, we need to increase comfort for the well-being of users. Also, our need for safety and security is constantly
www.usa.siemens.com/desigo-fire-safety
The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract.
All rights reserved. Printed in USA 153-FIS-110 ©2011 Siemens Industry, Inc.
Siemens Industry, Inc. 8 Fernwood Road Florham Park, NJ 07932 Tel (973) 593-2600 Fax (973) 593-6670
110507_Desigo_Fire.indd 1 11/10/11 9:31 AM
FCn
et/S
AFE
DLI
NK
Siemens owns one of the largest fire test lab-oratories in the world. We conduct live fire behavior tests in eight test labs. Our database contains more than 5,000 tests. We factor all of this information into the development of our Desigo fire detectors.
Intelligent technology for enhanced detection
One family to cover virtually any applicationDesigo fire detectors answer virtually any application need, from standard to sophis-ticated and from clean to dirty. The C-LINE detectors are an economical, reliable solu-tion for standard applications. The S-LINE detectors are the best choice for more demanding applications with deceptive phenomena, when extremely fast response time and the highest level of prevention of false alarms is needed. Detectors from both lines can be used together in a single network. In short, Desigo allows you to manage diverse detection requirements with one detector family and one system.
Unique sensor technology In multiple environmental conditions, Desigo detectors reliably detect any sign of fire as early as possible. Their unique sensor system utilizes state-of-the-art forward and backward light scattering technology. This technology provides advanced optical analysis of light and dark smoke particles. As a result, it improves the detection capabilities of the detectors
and makes them virtually immune to false alarms. Desigo detectors comply with NFPA 76 (Telecommunication Standard) and are classified as Very Early Warning Fire Detectors (VEWFD). This means that they are extremely sensitive and provide very early detection.
A smart choice for the environmentThe detectors are RoHS compliant, meeting the standards regarding the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment. S-LINE detectors also provide enhanced detection capability equivalent to ioniza-tion detectors due to their forward and backward light scattering technology. This makes them a great “green” solution.
Redundant sensors increase reliabilityS-LINE detectors have two thermal and two optical sensors. This redundancy heightens their immunity to deceptive phenomena and increases their detection capability and reliability. Should one sensor fail, the detec- tors will still provide fail-safe operation.
Highlights
■ One detector portfolio to cover most application areas, from clean to dirty
■ Reliable detection that eliminates false alarms due to unique forward and backward light scattering technology
■ Compliant with NFPA 76 (Telecommunication Standard) and classified as a VEWFD
■ RoHS compliant, with detection capability equivalent to ionization detectors due to forward and backward light scattering technology
■ Increased reliability and fail-safe operation thanks to redundant sensors
S-LINE – setting new standards with ASAtechnologyTM
Unsurpassed reliability Preventing downtime and costs caused by false alarms are central considerations for any company. ASAtechnology (Advanced Signal Analysis) offers extreme detec- tion reliability with the immunity to decep-tive phenomena. Therefore, we offer a No False Alarm Guarantee with this detector.
Sophisticated applications require exceptional technologyS-LINE detectors feature our unique ASAtechnology. This makes them highly reliable in preventing false alarms caused by deceptive on-site phenomena, such as machine exhaust gases, dust, or steam. This provides excellent protection and extremely reliable detection in critical applications, ranging from very clean environments like data centers and tele-communications centers to dirty industrial applications like warehouse facilities.
Highest life safetyThe multi-criteria fire/CO detector FDOOTC441 combines ASAtechnology
with carbon monoxide (CO) detection for maximum life safety. It responds very quickly and reliably to fire or the presence of CO. With two optical and two thermal sensors and one additional electrochemical CO sensor, FDOOTC441 analyzes fire criteria: smoke, heat, and CO. The addi-tional CO sensor ensures earliest detection of CO-generating fires and detects CO independently from fire. FDOOTC441 complies with the requirements of the fire safety and carbon monoxide codes and standards UL 2075 and NFPA 720.
Meeting changing needsS-LINE fire detectors offer more than 20 application-specific detection profiles that let you adjust the detectors to the expected environmental condition. Should the conditions change, you simply modify the detector by adjusting the detection profile. This provides for reliable and early fire detection even under changing environmental conditions.
Highlights
■ Unique detection reliability and No False Alarm Guarantee provided by ASAtechnology
■ Fast, reliable detection of smoke, heat, and carbon monoxide
■ Earliest detection of CO- generating fumes, also independently from fire, with the CO detector
■ Excellent life safety provided by selectable fire detection profiles
■ Adjustable detection profiles guarantee quick, cost-efficient adaptation to environmental conditions
Des
igo
Fire
Saf
ety
– d
etec
tors
an
d p
erip
her
als,
per
fect
ly c
onn
ecte
d
De
sig
o S
-LIN
E d
ete
cto
rs w
ith
AS
Ate
chn
olo
gyTM
– A
dvan
ced
mu
lti-
crit
eria
fir
e de
tect
or u
tiliz
ing
opti
cal,
ther
mal
, an
d op
tion
al C
O s
enso
r–
Exc
elle
nt
imm
un
ity
to d
ecep
tive
ph
eno
men
a w
hile
pro
vid
ing
en
han
ced
det
ecti
on
–
Pro
vid
e re
du
nd
ant
op
tica
l an
d t
her
mal
sen
sors
fo
r ex
trao
rdin
ary
relia
bili
ty–
Co
mp
ly w
ith
NFP
A 7
6 (
Tele
com
mu
nic
atio
n S
tan
dar
d)
as a
Ver
y Ea
rly
War
nin
g
Fire
Det
ecto
r (V
EWFD
) as
a r
esu
lt o
f h
igh
-sen
siti
vity
ala
rm c
apab
iliti
es–
Incl
ude
a m
ult
i-pu
rpo
se c
arbo
n m
on
oxid
e (C
O)
life
safe
ty a
nd
fire
det
ecto
r–
Sel
ecta
ble
as
a m
ult
i-cr
iter
ia f
ire
det
ecto
r an
d/o
r a
CO
life
saf
ety
gas
det
ecto
r–
En
viro
nm
enta
lly f
rien
dly
“g
reen
” d
etec
tors
, as
th
ey a
re R
oH
S-co
mp
lian
t an
d
rep
lace
th
e n
eed
fo
r io
niz
atio
n d
etec
tors
du
e to
fo
rwar
d/b
ackw
ard
lig
ht
sc
atte
rin
g t
ech
no
log
y–
Pro
vid
e m
ult
iple
sel
ecta
ble
tem
per
atu
re a
larm
th
resh
old
s, f
ixed
an
d r
ate-
of-
rise
– S
olu
tio
n f
or
stan
dar
d a
pp
licat
ion
s w
ith
ave
rag
e ri
sk a
nd
mo
der
ate
po
ten
tial
fo
r d
ecep
tive
ph
eno
men
a–
Pre
ven
t fa
lse
alar
ms
than
ks t
o in
telli
gen
t al
go
rith
ms
– O
ffer
mu
ltip
le s
elec
tab
le t
emp
erat
ure
ala
rm t
hre
sho
lds,
fix
ed a
nd
rate
-of-
rise
– O
ffer
wid
e o
per
atin
g t
emp
erat
ure
& r
elat
ive
hu
mid
ity
(RH
) ra
ng
e–
“G
reen
” d
etec
tors
, as
th
ey a
re R
oH
S-co
mp
lian
t, m
eeti
ng
th
e
stan
dar
ds
reg
ard
ing
th
e re
stri
ctio
n o
f th
e u
se o
f ce
rtai
n
haz
ard
ou
s su
bst
ance
s in
ele
ctri
cal a
nd
ele
ctro
nic
eq
uip
men
t–
FD
OT4
21
is c
om
pat
ible
wit
h t
he
Fire
Fin
der
XLS
co
ntr
ol p
anel
– A
re c
on
nec
ted
to
au
tom
atic
fir
e d
etec
tors
th
at a
re n
ot
ea
sily
acc
essi
ble
or
visi
ble
– C
on
tain
an
ind
icat
or
lam
p u
nit
wit
h o
ne
or
two
LED
s w
hic
h w
ill li
gh
t u
p w
hen
th
e co
nn
ecte
d d
etec
tor
tr
igg
ers
an a
larm
– B
ackw
ard
co
mp
atib
le w
ith
H-s
erie
s d
etec
tor
– S
ame
foo
tpri
nt
as e
xist
ing
Sie
men
s d
uct
ho
usi
ng
s–
Incl
ud
e o
pti
on
al r
emo
te t
est
feat
ure
an
d in
dic
ato
r–
New
, im
pro
ved
fea
ture
s in
clu
de
easy
inst
alla
tio
n,
im
pro
ved
op
erat
ing
tem
per
atu
re r
ang
e, a
nd
op
tio
nal
in
-du
ct c
arb
on
mo
nox
ide
(CO
) d
etec
tio
n
– A
re f
or
imm
edia
te m
anu
al a
ctu
atio
n o
f a
fire
ala
rm o
r an
ext
ing
uis
hin
g p
roce
ss
– D
irec
t al
arm
act
uat
ion
by
pu
llin
g d
ow
n lo
ckin
g le
ver
– F
or
ind
oo
r an
d o
utd
oo
r ap
plic
atio
ns
– F
or
surf
ace-
an
d r
eces
s-m
ou
nte
d f
eed
lin
es in
eas
ily a
cces
sib
le p
lace
s
Man
ual
pu
ll s
tati
on
s an
d a
cce
sso
rie
s
Sin
gle
act
ion
m
an
ua
l p
ull
st
ati
on
HM
S-S
Ord
er n
o.:
5
00
-03
32
00
Du
al
act
ion
m
an
ua
l p
ull
st
ati
on
HM
S-D
Ord
er n
o.:
5
00
-03
34
00
Sin
gle
act
ion
m
eta
l m
an
ua
l
pu
ll s
tati
on
HM
S-M
Ord
er n
o.:
5
00
-03
34
50
Ph
oto
de
tect
or
H
FPO
-11
Ord
er n
o.:
5
00
-03
48
00
Ph
oto
/Th
erm
al
d
ete
cto
r H
FP-1
1
Ord
er n
o.:
5
00
-03
32
90
The
rma
l d
ete
cto
r H
FPT-
11
Ord
er n
o.:
5
00
-03
33
80
Fire
co
ntr
ol
pa
ne
l FC
20
25
Fire
co
ntr
ol
pa
ne
l FC
20
50
De
sig
o C
-LIN
E p
oin
t d
ete
cto
rs
Re
mo
te in
dic
ato
rsA
ir d
uct
ho
usi
ng
s
Mu
lti-
crit
eri
a
fire
de
tect
or
FDO
T42
1
Ord
er n
o.:
S5
43
20
-F6
-A1
Op
tica
l
(ph
oto
ele
ctri
c)
smo
ke d
ete
cto
r FD
O4
21
Ord
er n
o.:
S5
43
20
-F4
-A1
Re
mo
te in
dic
ato
r ce
ilin
g m
ou
nt
ILE
D-H
C
Ord
er n
o.:
5
00
-04
88
09
Air
du
ct h
ou
sin
g
wit
h r
ela
ys
FDB
Z4
92
-HR
Ord
er n
o.:
S5
43
19
-B2
3-A
1
Op
tio
na
l w
ea
the
r-p
roo
f e
ncl
osu
re
FDB
Z-W
P
Ord
er n
o.:
S5
43
19
-B2
6-A
1
The
rma
l
(he
at)
de
tect
or
FDT4
21
Ord
er n
o.:
S5
43
20
-F5
-A1
Re
mo
te in
dic
ato
r w
all
mo
un
t IL
ED
-HW
Ord
er n
o.:
5
00
-04
86
37
Air
du
ct h
ou
sin
g
FDB
Z4
92
Ord
er n
o.:
S5
43
19
-B2
2-A
1
Mu
lti-
crit
eri
a
fire
de
tect
or
FDO
OT4
41
Ord
er n
o.:
S5
43
20
-F7
-A1
Ce
ilin
g m
ou
nt
rem
ote
la
mp
R
L-H
C
Ord
er n
o.:
5
00
-03
32
30
Ce
ilin
g m
ou
nt
rem
ote
la
mp
R
L-H
C
Ord
er n
o.:
5
00
-03
32
30
Wa
ll m
ou
nt
rem
ote
la
mp
R
L-H
W
Ord
er n
o.:
5
00
-03
33
10
Wa
ll m
ou
nt
rem
ote
la
mp
R
L-H
W
Ord
er n
o.:
5
00
-03
33
10
Mu
lti-
crit
eri
a
fire
/CO
de
tect
or
FDO
OTC
44
1
Ord
er n
o.:
S5
43
20
-F8
-A1
De
tect
or
ba
se
DB
-11
Ord
er n
o.:
5
00
-09
41
51
De
tect
or
ba
se
DB
-11
Ord
er n
o.:
5
00
-09
41
51
De
tect
or
ba
se
DB
-11
E
Ord
er n
o.:
5
00
-09
41
51
E
De
tect
or
ba
se
DB
-11
E
Ord
er n
o.:
5
00
-09
41
51
E
De
tect
or
rela
y b
ase
D
B2
-HR
Ord
er n
o.:
S5
43
70
-F1
2-A
1
De
tect
or
rela
y b
ase
D
B2
-HR
Ord
er n
o.:
S5
43
70
-F1
2-A
1
– In
telli
gen
tly
con
nec
t in
dep
end
ent,
po
ten
tial
-fre
e m
ake-
or-
bre
ak c
on
tact
s –
Can
be
ind
epen
den
tly
con
fig
ure
d v
ia a
fir
e co
ntr
ol p
anel
fo
r st
atu
s o
r al
arm
mes
sag
es–
Inp
ut
mo
du
les
mo
nit
or
dev
ices
res
po
nsi
ble
fo
r al
arm
inp
uts
an
d c
on
firm
sig
nal
s o
r te
chn
ical
sta
tes
etc.
–
Ou
tpu
t m
od
ule
s co
ntr
ol o
ther
eq
uip
men
t, s
uch
as
do
or
ho
lder
s, f
ire
dam
per
s, s
mo
ke c
on
tro
l sys
tem
s, p
lan
t sh
utd
ow
n e
tc.
– F
DC
IO4
22
pro
vid
es c
lass
A w
irin
g a
nd
su
per
visi
on
Lin
e m
od
ule
s
H-s
eri
es
de
tect
ors
an
d b
ase
s
– E
xist
ing
det
ecto
rs f
rom
oth
er f
ire
pro
tect
ion
sys
tem
s fr
om
Si
emen
s, s
uch
as
the
H-s
erie
s, c
an a
lso
be
pla
ced
on
th
e FD
net
to
get
her
wit
h D
esig
o d
evic
es Au
dib
le b
ase
A
DB
H-1
1
Ord
er n
o.:
50
0-0
33
21
0
DB
2-H
R
RL-
HC
RL-
HW
FDn
et
Co
ntr
ol
po
int
H
CP
Ord
er n
o.:
5
00
-03
48
60
Co
nve
nti
on
al
zo
ne
mo
du
le
HZ
M
Ord
er n
o.:
5
00
-03
48
50
Lin
e is
ola
tor
H
LIM
Ord
er n
o.:
5
00
-03
31
70
Inp
ut/
ou
tpu
t
mo
du
le
FDC
IO4
22
– 4
inp
uts
, 4
ou
tpu
ts–
Cla
ss A
an
d B
wir
ing
Ord
er n
o.:
S5
43
22
-F4
-A1
Min
i sin
gle
in
pu
t in
terf
ace
m
od
ule
HTR
I-M
Ord
er n
o.:
5
00
-03
40
00
Sin
gle
inp
ut
in
terf
ace
mo
du
le
wit
h r
ela
y H
TRI-
R
Ord
er n
o.:
5
00
-03
33
00
Du
al
inp
ut
in
terf
ace
mo
du
le
HTR
I-D
Ord
er n
o.:
5
00
-03
33
60
Sin
gle
inp
ut
in
terf
ace
mo
du
le
HTR
I-S
Ord
er n
o.:
5
00
-03
33
70
110507_Desigo_Fire.indd 2 11/10/11 9:31 AM