2
Answers for infrastructure. 1 2 4 7 3 5 6 8 11 12 9 10 13 1 2 2 3 4 5 1 2 3 4 5 6 7 8 9 10 Desigo Fire Safety – control panels for all of your needs Desigo Fire Safety control panels – design and possibilities Management Station Desigo CC Peripheral device BACnet TCP/IP/LAN Remote access with Desigo Fire Safety View Fire control panel FC2025 Fire control panel FC2025 Fire terminal FT2050 Fire terminal FT2050 Fire control panel FC2025 Fire control panel FC2005-U2 Order no.: S54400-A9-A1 Fire control panel FC2050 Fire control panel FC2050 ASAtechnology detector ASAtechnology detector Notification appliance Notification appliance Periphery board FCI2016-U1 – Supports 252 devices – For FC2025 Order no.: S54400-A55-A1 Periphery board FCI2017-U1 – Supports 504 devices – For FC2050 Order no.: S54400-A56-A1 Option module (LED) FCM2023-U2 – Optionally available Order no.: S54400-C45-A1 Option module (blank) FCM2022-U2 – Optionally available Order no.: S54400-C44-A1 SAFEDLINK FN2001-U1 – Network module Order no.: S54400-A60-A1 Remote display FT2014-U2 – Black Order no.: S54400-F67-A1 Remote display FT2014-R2 – Red Order no.: S54400-B75-A1 Remote terminal FT2015-U2 – Incl. key switch, black Order no.: S54400-F68-A1 Remote terminal FT2015-R2 – Incl. key switch, red Order no.: S54400-B15-A1 Battery bracket FHA2032-U1 – Secures batteries to meet seismic requirements Order no.: S54400-B43-A1 RS485 class A module FCA2016-A1 – For serial RS485 circuit Order no.: S54400-A39-A1 Leased line/city tie module FCI2020-U1 – Can be configured with the ‘Leased line’ or ‘City tie’ functions Order no.: S54400-A57-A1 Remote peripheral module FCA2018-U1 – Interface to remote printers Order no.: S54400-A65-A1 License key FCA2012-U1 – Activates the Desigo Fire Safety View function Order no.: S54400-P102-A1 NAC expansion FCI2011-U1 – Adds notification appliance circuits Order no.: S54400-A54-A1 Releasing module XCI2001-U1 – Releasing for pre-action/deluge sprinkler Order no.: S54400-A69-A1 Fire terminal board FTI2001-A1 - For FT2050 fire terminal Order no.: S54400-A58-A1 Expansion and networking options FC2025/FC2050 Power supply (170 W) FP2011-U1 – Incl. connection cable Order no.: 500-450222 Power supply (300 W) FP2012-U1 – Incl. connection cable Order no.: S54400-Z60-A1 Power supply (170 W) FP2011-U1 – Incl. connection cable Order no.: 500-450222 Power supply FC2025/FC2050 Power supply FC2005 Back box FHB2001-U1 – 1 HU, black Order no.: S54400-B47-A1 Back box FHB2001-R1 – 1 HU, red Order no.: S54400-B47-A2 Back box FHB2002-U1 – 2 HU, black Order no.: S54400-B48-A1 Back box FHB2002-R1 – 2 HU, red Oder no.: S54400-B48-A2 Outer door FHD2001-U2 – 1 HU, black Order no.: S54400-B49-A1 Outer door FHD2001-R2 – 1 HU, red Order no.: S54400-B49-A2 Outer door FHD2002-U2 – 2 HU, black – 1 window Order no.: S54400-B50-A1 Outer door FHD2002-R2 – 2 HU, red – 1 window Order no.: S54400-B50-A2 Outer door FHD2003-U2 – 2 HU, black – 2 windows Order no.: S54400-B51-A1 Outer door FHD2003-R2 – 2 HU, red – 2 windows Order no.: S54400-B51-A2 Inner door FHD2004-U1 – Black Order no.: S54400-B52-A1 Trim kit FHA2035-U1 and FHA2035-R1 1HU, black and red Order no.: S54400-B42-A1 (black) Order no.: S54400-B44-A2 (red) Trim kit FHA2036-U1 and FHA2036-R1 Order no.: S54400-B41-A1 (black) Order no.: S54400-B42-A2 (red) Housings FC2025/FC2050 System operating units FC2025/FC2050 System operating units FC2005 Expansion options FC2005 Operating unit FCM2018-U2 Order no.: S54400-C40-A1 Operating unit FCM2019-U2 – With LED Order no.: S54400-C41-A1 Main board and operator unit FCM901-U2 – Interface options for loops, NACs, relays, aux. power, communication bus, city tie/ leased line module – System LCD display, LEDs, control buttons Order no.: S54433-B100-A1 Leased line/city tie module FCI2020-U1 – Same as FC2025/FC2050 Order no.: S54400-A57-A1 Remote display FSD901-U2 – Black Order no.: S54433-C102-A4 Remote terminal FSD901-R2 – Red Order no.: S54433-C102-A3 Battery bracket FHA901-U1 – Secures batteries to meet seismic requirements Order no.: S54433-B107-A1 Housings FC2005 Housing FH901-U2 – Black Order no.: S54433-B103-A1 Housing FH901-R2 – Red Order no.: S54433-B103-A2 Trim kit FHA902-U1 black Order no.: S54433-B103-A3 Trim kit FHA902-R1 red Order no.: S54433-B103-A4 1 Outer door FHD2002-U2 2 HU, 1 window, black – FHD2002-R2 2 HU, 1 window, red – FHD2003-U2 2 HU, 2 windows, black – FHD2003-R2 2 HU, 2 windows, red 4 Operator interface – FCM2018-U2 standard operating unit – FCM2019-U2 operating unit with LEDs 6 SAFEDLINK – FN2001-U1 7 Periphery board – FCI2016-U1 252 pt – FCI2017-U1 504 pt 8 Back box – FHB2002-U1 2 HU, black – FHB2002-R1 2 HU, red 2 Clear window – FHD2006-U1 3 Inner door – FHD2004-U1 with opening 11 Power supply – FP2011-U1 170 W, 24 VDC – FP2012-U1 300 W, 24 VDC 12 Battery bracket – FHA2032-U1 9 DACT – FCA2015-A1 10 Fiber module (SM and MM) – FN2006-U1 single-mode fiber – FN2007-U1 multi-mode fiber 13 Inner door – FHD2005-U1 solid 5 RS485 – FCA2016-A1 1 Main board and operator unit – FCM901-U2 4 Operator interface – FCM2018-U2 standard operating unit – FCM2019-U2 operating unit with LEDs 2 Clear window – FHD2006-U1 1 Outer door – FHD2001-U2 1 HU, black – FHD2001-R2 1 HU, red 3 Inner door – FHD2004-U1 with opening 6 SafeDLink module – FN2001-U1 5 RS485 – FCA2016-A1 2 Housing – With back box, door, window – FH901-U2 black – FH901-R2 red 8 Back box – FHB2001-U1 1 HU, black – FHB2001-R1 1 HU, red 7 Fire terminal board – FTI2001-A1 5 City tie – FCI2020-U1 10 Fiber module (SM and MM) – FN2006-U1 single-mode fiber – FN2007-U1 multi-mode fiber 4 Battery bracket – FHA901-U1 3 Power supply – FP2011-U1 170 W, 24 VDC 9 DACT – FCA2015-U1 Desigo TM Fire Safety Planning Tool FC2025/FC2050 networkable control panels FC2005 stand-alone control panel FT2050 fire terminal Remote display FT2014-U2 Order no.: S54400-F67-A1 Remote terminal FT2015-U2 Order no.: S54400-F68-A1 Remote terminal FSD901-U2 Order no.: S54433-C102-A4 Customer network NAC NAC RS485 FCnet/SAFEDLINK FDnet FDnet RS485 growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. “We are the preferred partner for energy-efficient, safe, and secure buildings and infrastructure.” Answers for infrastructure. Our world is undergoing changes that force us to think in new ways: demographic change, urbanization, global warming, and resource shortages. Maximum efficiency has top priority – and not only where energy is concerned. In addition, we need to increase comfort for the well-being of users. Also, our need for safety and security is constantly www.usa.siemens.com/desigo-fire-safety The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. All rights reserved. Printed in USA 153-FIS-110 ©2011 Siemens Industry, Inc. Siemens Industry, Inc. 8 Fernwood Road Florham Park, NJ 07932 Tel (973) 593-2600 Fax (973) 593-6670

Desigo_Planningtool

  • Upload
    wermerm

  • View
    66

  • Download
    6

Embed Size (px)

Citation preview

Page 1: Desigo_Planningtool

Answers for infrastructure.

1

2

4

7

3

56

8

11

12

9

10

13

1

2

2

3

4

5

1

2

3

4

56

7

8

9

10

Desigo Fire Safety – control panels for all of your needs

Desigo Fire Safety control panels – design and possibilities

Management Station Desigo CC

Peripheral device

BA

Cn

et

TCP/

IP/L

AN

Remote access with Desigo Fire Safety View

Fire control panel FC2025

Fire control panel FC2025

Fire terminal FT2050

Fire terminal FT2050

Fire control panel

FC2025

Fire control panel

FC2005-U2

Order no.: S54400-A9-A1

Fire control panel FC2050

Fire control panel FC2050

ASAtechnology detector

ASAtechnology detector

Notification appliance

Notification appliance

Periphery board FCI2016-U1 – Supports 252 devices – For FC2025 Order no.: S54400-A55-A1

Periphery board FCI2017-U1 – Supports 504 devices – For FC2050 Order no.: S54400-A56-A1

Option module (LED) FCM2023-U2 – Optionally available Order no.: S54400-C45-A1

Option module (blank) FCM2022-U2 – Optionally available Order no.: S54400-C44-A1

SAFEDLINK FN2001-U1– Network module Order no.: S54400-A60-A1

Remote display FT2014-U2– Black Order no.: S54400-F67-A1

Remote display FT2014-R2 – Red Order no.: S54400-B75-A1

Remote terminal FT2015-U2 – Incl. key switch, blackOrder no.: S54400-F68-A1

Remote terminal FT2015-R2 – Incl. key switch, redOrder no.: S54400-B15-A1

Battery bracket FHA2032-U1 – Secures batteries to meet

seismic requirements Order no.: S54400-B43-A1

RS485 class A module FCA2016-A1 – For serial RS485 circuit Order no.: S54400-A39-A1

Leased line/city tie module FCI2020-U1 – Can be configured with

the ‘Leased line’ or ‘City tie’ functions

Order no.: S54400-A57-A1

Remote peripheral module FCA2018-U1 – Interface to remote printers Order no.: S54400-A65-A1

License key FCA2012-U1 – Activates the Desigo Fire Safety

View functionOrder no.: S54400-P102-A1

NAC expansion FCI2011-U1 – Adds notification appliance

circuitsOrder no.: S54400-A54-A1

Releasing module XCI2001-U1 – Releasing for pre-action/deluge

sprinklerOrder no.: S54400-A69-A1

Fire terminal board FTI2001-A1- For FT2050 fire terminal Order no.: S54400-A58-A1

Expansion and networking options FC2025/FC2050

Power supply (170 W) FP2011-U1– Incl. connection cable Order no.: 500-450222

Power supply (300 W) FP2012-U1 – Incl. connection cable Order no.: S54400-Z60-A1

Power supply (170 W) FP2011-U1– Incl. connection cable Order no.: 500-450222

Power supply FC2025/FC2050

Power supply FC2005

Back box FHB2001-U1– 1 HU, black Order no.: S54400-B47-A1

Back box FHB2001-R1– 1 HU, red Order no.: S54400-B47-A2

Back box FHB2002-U1– 2 HU, black Order no.: S54400-B48-A1

Back box FHB2002-R1– 2 HU, red Oder no.: S54400-B48-A2

Outer door FHD2001-U2– 1 HU, black Order no.: S54400-B49-A1

Outer door FHD2001-R2– 1 HU, red Order no.: S54400-B49-A2

Outer door FHD2002-U2– 2 HU, black – 1 window Order no.: S54400-B50-A1

Outer door FHD2002-R2– 2 HU, red – 1 window Order no.: S54400-B50-A2

Outer door FHD2003-U2– 2 HU, black – 2 windows Order no.: S54400-B51-A1

Outer door FHD2003-R2– 2 HU, red – 2 windows Order no.: S54400-B51-A2

Inner door FHD2004-U1– Black Order no.: S54400-B52-A1

Trim kit FHA2035-U1 and FHA2035-R1 – 1HU, black and red Order no.: S54400-B42-A1 (black) Order no.: S54400-B44-A2 (red)

Trim kit FHA2036-U1 and FHA2036-R1 Order no.: S54400-B41-A1 (black)Order no.: S54400-B42-A2 (red)

Housings FC2025/FC2050

System operating units FC2025/FC2050

System operating units FC2005

Expansion options FC2005Operating unit FCM2018-U2Order no.: S54400-C40-A1

Operating unit FCM2019-U2– With LED Order no.: S54400-C41-A1

Main board and operator unit FCM901-U2 – Interface options for loops,

NACs, relays, aux. power, communication bus, city tie/leased line module

– System LCD display, LEDs, control buttons

Order no.: S54433-B100-A1

Leased line/city tie module FCI2020-U1 – Same as FC2025/FC2050 Order no.: S54400-A57-A1

Remote display FSD901-U2 – Black Order no.: S54433-C102-A4

Remote terminal FSD901-R2 – Red Order no.: S54433-C102-A3

Battery bracket FHA901-U1 – Secures batteries to meet

seismic requirementsOrder no.: S54433-B107-A1

Housings FC2005

Housing FH901-U2 – Black Order no.: S54433-B103-A1

Housing FH901-R2– Red Order no.: S54433-B103-A2

Trim kit FHA902-U1 – blackOrder no.: S54433-B103-A3

Trim kit FHA902-R1– redOrder no.: S54433-B103-A4

1 Outer door

– FHD2002-U2 2 HU, 1 window, black

– FHD2002-R2 2 HU, 1 window, red

– FHD2003-U2 2 HU, 2 windows, black

– FHD2003-R2 2 HU, 2 windows, red

4 Operator interface

– FCM2018-U2 standard operating unit

– FCM2019-U2 operating unit with LEDs

6 SAFEDLINK

– FN2001-U1

7 Periphery board

– FCI2016-U1 252 pt

– FCI2017-U1 504 pt

8 Back box

– FHB2002-U1 2 HU, black

– FHB2002-R1 2 HU, red

2 Clear window

– FHD2006-U1

3 Inner door

– FHD2004-U1 with opening

11 Power supply

– FP2011-U1 170 W, 24 VDC

– FP2012-U1 300 W, 24 VDC

12 Battery bracket

– FHA2032-U1

9 DACT

– FCA2015-A1

10 Fiber module (SM and MM)

– FN2006-U1 single-mode fiber

– FN2007-U1 multi-mode fiber

13 Inner door

– FHD2005-U1 solid

5 RS485

– FCA2016-A1

1 Main board and operator unit

– FCM901-U2

4 Operator interface

– FCM2018-U2 standard operating unit

– FCM2019-U2 operating unit with LEDs

2 Clear window

– FHD2006-U1

1 Outer door

– FHD2001-U2 1 HU, black

– FHD2001-R2 1 HU, red

3 Inner door

– FHD2004-U1 with opening

6 SafeDLink module

– FN2001-U1

5 RS485

– FCA2016-A1

2 Housing

– With back box, door, window

– FH901-U2 black

– FH901-R2 red

8 Back box

– FHB2001-U1 1 HU, black

– FHB2001-R1 1 HU, red

7 Fire terminal board

– FTI2001-A1

5 City tie

– FCI2020-U1

10 Fiber module (SM and MM)

– FN2006-U1 single-mode fiber

– FN2007-U1 multi-mode fiber

4 Battery bracket

– FHA901-U1

3 Power supply

– FP2011-U1 170 W, 24 VDC

9 DACT

– FCA2015-U1

DesigoTM Fire Safety Planning Tool

FC2025/FC2050 networkable control panels

FC2005 stand-alone control panel

FT2050 fire terminal

Remote display FT2014-U2

Order no.: S54400-F67-A1

Remote terminal FT2015-U2

Order no.: S54400-F68-A1

Remote terminal FSD901-U2

Order no.: S54433-C102-A4

Customer network

NAC NAC

RS4

85

FCnet/SAFEDLINK

FDnet FDnet

RS4

85

growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. “We are the preferred partner for energy-efficient, safe, and secure buildings and infrastructure.”

Answers for infrastructure.Our world is undergoing changes that force us to think in new ways: demographic change, urbanization, global warming, and resource shortages. Maximum efficiency has top priority – and not only where energy is concerned. In addition, we need to increase comfort for the well-being of users. Also, our need for safety and security is constantly

www.usa.siemens.com/desigo-fire-safety

The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract.

All rights reserved. Printed in USA 153-FIS-110 ©2011 Siemens Industry, Inc.

Siemens Industry, Inc. 8 Fernwood Road Florham Park, NJ 07932 Tel (973) 593-2600 Fax (973) 593-6670

110507_Desigo_Fire.indd 1 11/10/11 9:31 AM

Page 2: Desigo_Planningtool

FCn

et/S

AFE

DLI

NK

Siemens owns one of the largest fire test lab-oratories in the world. We conduct live fire behavior tests in eight test labs. Our database contains more than 5,000 tests. We factor all of this information into the development of our Desigo fire detectors.

Intelligent technology for enhanced detection

One family to cover virtually any applicationDesigo fire detectors answer virtually any application need, from standard to sophis-ticated and from clean to dirty. The C-LINE detectors are an economical, reliable solu-tion for standard applications. The S-LINE detectors are the best choice for more demanding applications with deceptive phenomena, when extremely fast response time and the highest level of prevention of false alarms is needed. Detectors from both lines can be used together in a single network. In short, Desigo allows you to manage diverse detection requirements with one detector family and one system.

Unique sensor technology In multiple environmental conditions, Desigo detectors reliably detect any sign of fire as early as possible. Their unique sensor system utilizes state-of-the-art forward and backward light scattering technology. This technology provides advanced optical analysis of light and dark smoke particles. As a result, it improves the detection capabilities of the detectors

and makes them virtually immune to false alarms. Desigo detectors comply with NFPA 76 (Telecommunication Standard) and are classified as Very Early Warning Fire Detectors (VEWFD). This means that they are extremely sensitive and provide very early detection.

A smart choice for the environmentThe detectors are RoHS compliant, meeting the standards regarding the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment. S-LINE detectors also provide enhanced detection capability equivalent to ioniza-tion detectors due to their forward and backward light scattering technology. This makes them a great “green” solution.

Redundant sensors increase reliabilityS-LINE detectors have two thermal and two optical sensors. This redundancy heightens their immunity to deceptive phenomena and increases their detection capability and reliability. Should one sensor fail, the detec- tors will still provide fail-safe operation.

Highlights

■ One detector portfolio to cover most application areas, from clean to dirty

■ Reliable detection that eliminates false alarms due to unique forward and backward light scattering technology

■ Compliant with NFPA 76 (Telecommunication Standard) and classified as a VEWFD

■ RoHS compliant, with detection capability equivalent to ionization detectors due to forward and backward light scattering technology

■ Increased reliability and fail-safe operation thanks to redundant sensors

S-LINE – setting new standards with ASAtechnologyTM

Unsurpassed reliability Preventing downtime and costs caused by false alarms are central considerations for any company. ASAtechnology (Advanced Signal Analysis) offers extreme detec- tion reliability with the immunity to decep-tive phenomena. Therefore, we offer a No False Alarm Guarantee with this detector.

Sophisticated applications require exceptional technologyS-LINE detectors feature our unique ASAtechnology. This makes them highly reliable in preventing false alarms caused by deceptive on-site phenomena, such as machine exhaust gases, dust, or steam. This provides excellent protection and extremely reliable detection in critical applications, ranging from very clean environments like data centers and tele-communications centers to dirty industrial applications like warehouse facilities.

Highest life safetyThe multi-criteria fire/CO detector FDOOTC441 combines ASAtechnology

with carbon monoxide (CO) detection for maximum life safety. It responds very quickly and reliably to fire or the presence of CO. With two optical and two thermal sensors and one additional electrochemical CO sensor, FDOOTC441 analyzes fire criteria: smoke, heat, and CO. The addi-tional CO sensor ensures earliest detection of CO-generating fires and detects CO independently from fire. FDOOTC441 complies with the requirements of the fire safety and carbon monoxide codes and standards UL 2075 and NFPA 720.

Meeting changing needsS-LINE fire detectors offer more than 20 application-specific detection profiles that let you adjust the detectors to the expected environmental condition. Should the conditions change, you simply modify the detector by adjusting the detection profile. This provides for reliable and early fire detection even under changing environmental conditions.

Highlights

■ Unique detection reliability and No False Alarm Guarantee provided by ASAtechnology

■ Fast, reliable detection of smoke, heat, and carbon monoxide

■ Earliest detection of CO- generating fumes, also independently from fire, with the CO detector

■ Excellent life safety provided by selectable fire detection profiles

■ Adjustable detection profiles guarantee quick, cost-efficient adaptation to environmental conditions

Des

igo

Fire

Saf

ety

– d

etec

tors

an

d p

erip

her

als,

per

fect

ly c

onn

ecte

d

De

sig

o S

-LIN

E d

ete

cto

rs w

ith

AS

Ate

chn

olo

gyTM

– A

dvan

ced

mu

lti-

crit

eria

fir

e de

tect

or u

tiliz

ing

opti

cal,

ther

mal

, an

d op

tion

al C

O s

enso

r–

Exc

elle

nt

imm

un

ity

to d

ecep

tive

ph

eno

men

a w

hile

pro

vid

ing

en

han

ced

det

ecti

on

Pro

vid

e re

du

nd

ant

op

tica

l an

d t

her

mal

sen

sors

fo

r ex

trao

rdin

ary

relia

bili

ty–

Co

mp

ly w

ith

NFP

A 7

6 (

Tele

com

mu

nic

atio

n S

tan

dar

d)

as a

Ver

y Ea

rly

War

nin

g

Fire

Det

ecto

r (V

EWFD

) as

a r

esu

lt o

f h

igh

-sen

siti

vity

ala

rm c

apab

iliti

es–

Incl

ude

a m

ult

i-pu

rpo

se c

arbo

n m

on

oxid

e (C

O)

life

safe

ty a

nd

fire

det

ecto

r–

Sel

ecta

ble

as

a m

ult

i-cr

iter

ia f

ire

det

ecto

r an

d/o

r a

CO

life

saf

ety

gas

det

ecto

r–

En

viro

nm

enta

lly f

rien

dly

“g

reen

” d

etec

tors

, as

th

ey a

re R

oH

S-co

mp

lian

t an

d

rep

lace

th

e n

eed

fo

r io

niz

atio

n d

etec

tors

du

e to

fo

rwar

d/b

ackw

ard

lig

ht

sc

atte

rin

g t

ech

no

log

y–

Pro

vid

e m

ult

iple

sel

ecta

ble

tem

per

atu

re a

larm

th

resh

old

s, f

ixed

an

d r

ate-

of-

rise

– S

olu

tio

n f

or

stan

dar

d a

pp

licat

ion

s w

ith

ave

rag

e ri

sk a

nd

mo

der

ate

po

ten

tial

fo

r d

ecep

tive

ph

eno

men

a–

Pre

ven

t fa

lse

alar

ms

than

ks t

o in

telli

gen

t al

go

rith

ms

– O

ffer

mu

ltip

le s

elec

tab

le t

emp

erat

ure

ala

rm t

hre

sho

lds,

fix

ed a

nd

rate

-of-

rise

– O

ffer

wid

e o

per

atin

g t

emp

erat

ure

& r

elat

ive

hu

mid

ity

(RH

) ra

ng

e–

“G

reen

” d

etec

tors

, as

th

ey a

re R

oH

S-co

mp

lian

t, m

eeti

ng

th

e

stan

dar

ds

reg

ard

ing

th

e re

stri

ctio

n o

f th

e u

se o

f ce

rtai

n

haz

ard

ou

s su

bst

ance

s in

ele

ctri

cal a

nd

ele

ctro

nic

eq

uip

men

t–

FD

OT4

21

is c

om

pat

ible

wit

h t

he

Fire

Fin

der

XLS

co

ntr

ol p

anel

– A

re c

on

nec

ted

to

au

tom

atic

fir

e d

etec

tors

th

at a

re n

ot

ea

sily

acc

essi

ble

or

visi

ble

– C

on

tain

an

ind

icat

or

lam

p u

nit

wit

h o

ne

or

two

LED

s w

hic

h w

ill li

gh

t u

p w

hen

th

e co

nn

ecte

d d

etec

tor

tr

igg

ers

an a

larm

– B

ackw

ard

co

mp

atib

le w

ith

H-s

erie

s d

etec

tor

– S

ame

foo

tpri

nt

as e

xist

ing

Sie

men

s d

uct

ho

usi

ng

s–

Incl

ud

e o

pti

on

al r

emo

te t

est

feat

ure

an

d in

dic

ato

r–

New

, im

pro

ved

fea

ture

s in

clu

de

easy

inst

alla

tio

n,

im

pro

ved

op

erat

ing

tem

per

atu

re r

ang

e, a

nd

op

tio

nal

in

-du

ct c

arb

on

mo

nox

ide

(CO

) d

etec

tio

n

– A

re f

or

imm

edia

te m

anu

al a

ctu

atio

n o

f a

fire

ala

rm o

r an

ext

ing

uis

hin

g p

roce

ss

– D

irec

t al

arm

act

uat

ion

by

pu

llin

g d

ow

n lo

ckin

g le

ver

– F

or

ind

oo

r an

d o

utd

oo

r ap

plic

atio

ns

– F

or

surf

ace-

an

d r

eces

s-m

ou

nte

d f

eed

lin

es in

eas

ily a

cces

sib

le p

lace

s

Man

ual

pu

ll s

tati

on

s an

d a

cce

sso

rie

s

Sin

gle

act

ion

m

an

ua

l p

ull

st

ati

on

HM

S-S

Ord

er n

o.:

5

00

-03

32

00

Du

al

act

ion

m

an

ua

l p

ull

st

ati

on

HM

S-D

Ord

er n

o.:

5

00

-03

34

00

Sin

gle

act

ion

m

eta

l m

an

ua

l

pu

ll s

tati

on

HM

S-M

Ord

er n

o.:

5

00

-03

34

50

Ph

oto

de

tect

or

H

FPO

-11

Ord

er n

o.:

5

00

-03

48

00

Ph

oto

/Th

erm

al

d

ete

cto

r H

FP-1

1

Ord

er n

o.:

5

00

-03

32

90

The

rma

l d

ete

cto

r H

FPT-

11

Ord

er n

o.:

5

00

-03

33

80

Fire

co

ntr

ol

pa

ne

l FC

20

25

Fire

co

ntr

ol

pa

ne

l FC

20

50

De

sig

o C

-LIN

E p

oin

t d

ete

cto

rs

Re

mo

te in

dic

ato

rsA

ir d

uct

ho

usi

ng

s

Mu

lti-

crit

eri

a

fire

de

tect

or

FDO

T42

1

Ord

er n

o.:

S5

43

20

-F6

-A1

Op

tica

l

(ph

oto

ele

ctri

c)

smo

ke d

ete

cto

r FD

O4

21

Ord

er n

o.:

S5

43

20

-F4

-A1

Re

mo

te in

dic

ato

r ce

ilin

g m

ou

nt

ILE

D-H

C

Ord

er n

o.:

5

00

-04

88

09

Air

du

ct h

ou

sin

g

wit

h r

ela

ys

FDB

Z4

92

-HR

Ord

er n

o.:

S5

43

19

-B2

3-A

1

Op

tio

na

l w

ea

the

r-p

roo

f e

ncl

osu

re

FDB

Z-W

P

Ord

er n

o.:

S5

43

19

-B2

6-A

1

The

rma

l

(he

at)

de

tect

or

FDT4

21

Ord

er n

o.:

S5

43

20

-F5

-A1

Re

mo

te in

dic

ato

r w

all

mo

un

t IL

ED

-HW

Ord

er n

o.:

5

00

-04

86

37

Air

du

ct h

ou

sin

g

FDB

Z4

92

Ord

er n

o.:

S5

43

19

-B2

2-A

1

Mu

lti-

crit

eri

a

fire

de

tect

or

FDO

OT4

41

Ord

er n

o.:

S5

43

20

-F7

-A1

Ce

ilin

g m

ou

nt

rem

ote

la

mp

R

L-H

C

Ord

er n

o.:

5

00

-03

32

30

Ce

ilin

g m

ou

nt

rem

ote

la

mp

R

L-H

C

Ord

er n

o.:

5

00

-03

32

30

Wa

ll m

ou

nt

rem

ote

la

mp

R

L-H

W

Ord

er n

o.:

5

00

-03

33

10

Wa

ll m

ou

nt

rem

ote

la

mp

R

L-H

W

Ord

er n

o.:

5

00

-03

33

10

Mu

lti-

crit

eri

a

fire

/CO

de

tect

or

FDO

OTC

44

1

Ord

er n

o.:

S5

43

20

-F8

-A1

De

tect

or

ba

se

DB

-11

Ord

er n

o.:

5

00

-09

41

51

De

tect

or

ba

se

DB

-11

Ord

er n

o.:

5

00

-09

41

51

De

tect

or

ba

se

DB

-11

E

Ord

er n

o.:

5

00

-09

41

51

E

De

tect

or

ba

se

DB

-11

E

Ord

er n

o.:

5

00

-09

41

51

E

De

tect

or

rela

y b

ase

D

B2

-HR

Ord

er n

o.:

S5

43

70

-F1

2-A

1

De

tect

or

rela

y b

ase

D

B2

-HR

Ord

er n

o.:

S5

43

70

-F1

2-A

1

– In

telli

gen

tly

con

nec

t in

dep

end

ent,

po

ten

tial

-fre

e m

ake-

or-

bre

ak c

on

tact

s –

Can

be

ind

epen

den

tly

con

fig

ure

d v

ia a

fir

e co

ntr

ol p

anel

fo

r st

atu

s o

r al

arm

mes

sag

es–

Inp

ut

mo

du

les

mo

nit

or

dev

ices

res

po

nsi

ble

fo

r al

arm

inp

uts

an

d c

on

firm

sig

nal

s o

r te

chn

ical

sta

tes

etc.

Ou

tpu

t m

od

ule

s co

ntr

ol o

ther

eq

uip

men

t, s

uch

as

do

or

ho

lder

s, f

ire

dam

per

s, s

mo

ke c

on

tro

l sys

tem

s, p

lan

t sh

utd

ow

n e

tc.

– F

DC

IO4

22

pro

vid

es c

lass

A w

irin

g a

nd

su

per

visi

on

Lin

e m

od

ule

s

H-s

eri

es

de

tect

ors

an

d b

ase

s

– E

xist

ing

det

ecto

rs f

rom

oth

er f

ire

pro

tect

ion

sys

tem

s fr

om

Si

emen

s, s

uch

as

the

H-s

erie

s, c

an a

lso

be

pla

ced

on

th

e FD

net

to

get

her

wit

h D

esig

o d

evic

es Au

dib

le b

ase

A

DB

H-1

1

Ord

er n

o.:

50

0-0

33

21

0

DB

2-H

R

RL-

HC

RL-

HW

FDn

et

Co

ntr

ol

po

int

H

CP

Ord

er n

o.:

5

00

-03

48

60

Co

nve

nti

on

al

zo

ne

mo

du

le

HZ

M

Ord

er n

o.:

5

00

-03

48

50

Lin

e is

ola

tor

H

LIM

Ord

er n

o.:

5

00

-03

31

70

Inp

ut/

ou

tpu

t

mo

du

le

FDC

IO4

22

– 4

inp

uts

, 4

ou

tpu

ts–

Cla

ss A

an

d B

wir

ing

Ord

er n

o.:

S5

43

22

-F4

-A1

Min

i sin

gle

in

pu

t in

terf

ace

m

od

ule

HTR

I-M

Ord

er n

o.:

5

00

-03

40

00

Sin

gle

inp

ut

in

terf

ace

mo

du

le

wit

h r

ela

y H

TRI-

R

Ord

er n

o.:

5

00

-03

33

00

Du

al

inp

ut

in

terf

ace

mo

du

le

HTR

I-D

Ord

er n

o.:

5

00

-03

33

60

Sin

gle

inp

ut

in

terf

ace

mo

du

le

HTR

I-S

Ord

er n

o.:

5

00

-03

33

70

110507_Desigo_Fire.indd 2 11/10/11 9:31 AM